You are on page 1of 2

DATA SHEET

U.I. Lapp
GmbH

LFLEX SOLAR XLR WP

DB 1023501EN
valid from: 22.04.2015

1. Application
LFLEX SOLAR XLR WP cables are weather-, abrasion- and UV-resistant photovoltaic cables. Due to optimized cable design, a constant high volume resistivity can be ensured even after long-term period in not contaminated water. An intentional
installation in or under water is not permitted. The cable is suitable for direct burial considering the common VDE installation
guide lines.
These cross-linked, halogen free and double insulated solar cables are suitable for permanent outdoor use and especially for
the interconnection of grounded and ungrounded photovoltaic power systems. They are applicable for the connection of
solar panels among themselves and as extension cable between the individual module strings or the DC/AC inverter.

2. Cable design
Design

according to TV specification 2 PfG 1169/08.2007 (PV1-F)

Certification

code designation PV1-F, certified according to 2 PfG 1169/08.2007


(TV certificate number R50202588)

1. Conductor:

Fine wire strands of tinned copper according to IEC 60228, Class 5

2. Core insulation:

Electron beam cross-linked polyolefin co-polymer


Colour: white

3. Outer sheath:

Electron beam cross-linked polyolefin co-polymer


Outer sheath colour: black or black with red or blue coloured stripe

3. Electrical properties
Rated voltage U0/U acc. IEC

AC 600/1000 V
DC 900/1500 V

Max. permissible operating voltage

DC 1800 V (conductor/conductor, non earthed system)


according to 2 PfG 1169/08.2007

Test voltage

AC 6,5 kV

4. Mechanical and thermal properties


Temperature range

fixed installation: -40C up to +120C


(max. conductor temperature according to EN 60216-2)

Temperature range according

fixed installation: -40C up to +90C ambient temperature


(according to TV 2 PfG 1169/08.2007)

Installation temperature

flexible: > -25C

Minimum bending radius

occasional flexing: 15 x cable diameter


fixed installation:
5 x cable diameter

Weathering/UV-resistance

according to HD 605/A1

Ozone resistance

according to EN 50396

Originator: A. Terpe / PCM


approved: PDC

Document:

DB1023501EN

All deviations from this specification are subject to explicit consent of U.I. Lapp GmbH. All rights reserved acc. to DIN 34.
PD 0019/2.1_11.09EN

page 1 of 2

DATA SHEET

U.I. Lapp
GmbH

LFLEX SOLAR XLR WP

DB 1023501EN
valid from: 22.04.2015

Halogen free

according to EN 50267, IEC 61034

Flame retardant

according to IEC 60332-1-2

Acid and alkaline resistance

according to EN 60811-2-1 (Oxal-acid and Sodium hydroxide)

Oil resistance

according to DIN EN 50290-2-22 resp. VDE 0819-102, TM54

Direct burial

according to UL 1277 chapter 19 (Crushing Test),


UL 854 chapter 23 (Impact-Resistance-Test) and
UL 854 chapter 24 (Crushing-Resistance Test)

EU directives

This cable is conform to the EU-Directives 2014/35/EU (Low Voltage Directive) and
2011/65/EU (RoHS, Restriction of the use of certain hazardous substances).

5. Underground installation
LFLEX SOLAR XLR WP cables are suitable for the installation underground if the cable is laid in a cable trench
according to VDE 0100, part 520 or comparable standards.
Storage or use of the cables in or under not contaminated water (salt or fresh water) is only permitted with the following conditions:
Water temperature:
Water pressure:

+45C (maximum)
0.08 bar; 8kPa (maximum)

6. Versions
Part.No.

Colour insulation

Colour outer sheath

1023501
1023502
1023503
1023504
1023505
1023521
1023522
1023523
1023524
1023525
1023526
1023527
1023528
1023529
1023530

white
white
white
white
white
white
white
white
white
white
white
white
white
white
white

black
black
black
black
black
black + red stripe
black + red stripe
black + red stripe
black + red stripe
black + red stripe
black + blue stripe
black + blue stripe
black + blue stripe
black + blue stripe
black + blue stripe

Originator: A. Terpe / PCM


approved: PDC

Document:

Conductor cross section Outer diameter approx.


[mm]
[mm]
1 x 2.5
5.2
1x4
5.6
1x6
6.2
1 x 10
7.4
1 x 16
8.7
1 x 2.5
5.2
1x4
5.6
1x6
6.2
1 x 10
7.4
1 x 16
8.7
1 x 2.5
5.2
1x4
5.6
1x6
6.2
1 x 10
7.4
1 x 16
8.7

DB1023501EN

All deviations from this specification are subject to explicit consent of U.I. Lapp GmbH. All rights reserved acc. to DIN 34.
PD 0019/2.1_11.09EN

page 2 of 2

You might also like