Power HT 45 - 150 kW
Technical specifications
Dimensions
Diagrams
Burner-exchanger unit
Wiring diagram
Wiring diagram for connection to an heating system
DHW circuit electric pump connections
Flue pipes (B23)
Dual flue system 45-65 kW
Dual flue system 85-150 kW
Electronics
Programming, setting and digital control
Single installation
Schemes for single installation
Cascade installation
Schemes for cascade installation
Hydraulic separators and condensate neutralizer kit
Other accessories
P.
136
137
138
139
140
142
143
144
145
146
147
148
150
153
158
164
168
169
135
Power HT 45-150 kW
Power HT is the range of high efficiency floor standing condensing boilers, heating only with
an output from 45 to 150 kW (80/60C)
The range of boilers is distinguished by high efficiency, easiness of use/and installation and a
wide range of accessories for single and cascade installations.
The main element of these condensing boilers is the heat exchanger that has a combustion
chamber and a stainless steel AISI 316L coils hydraulic circuit .
The reduced quantity of water in the exchanger allows a small heat inactivity and so a quick
answer to the changes in the heat needed by the system.
1.450
1.650
1.850
1.1000
1.1200
1.1500
kW
46,4
67
87,2
102,7
123,2
154
kW
45
65
85
100
120
150
kW
48,7
70,3
91,6
107,8
129,7
162
kW
11,8
13,4
32,2
35,8
39
40,4
kW
12,8
14,5
34,9
38,8
42,1
43,7
109,8
109,8
109,8
109,8
109,8
109,8
97,3
97,3
97,5
97,4
97,4
97,4
105,2
105,3
105,1
105
105,3
105,2
Efficiency at 30%
107,6
107,6
107,3
107,4
107,5
107,2
kPa
25
20
23,54
22,56
22,56
19,61
lt/sec
0,27
0,33
0,52
0,58
0,72
0,91
-5
-5
-5
-5
-5
-5
bar
bar
25/80
25/80
25/80
25/80
25/80
25/80
l/h
1.935
2.795
3.700
4.300
5.200
6.500
lt
5,1
6,5
13,7
21
23,3
25,3
lt/h
5,1
7,3
9,6
11,5
13,5
16,9
mm
80
80
100
100
100
100
30
20
20
20
20
20
kg/s
0,022
0,031
0,041
0,049
0,059
0,073
kg/s
0,006
0,007
0,016
0,018
0,019
0,02
72
73
78
80
77
75
Pa
130
120
135
150
115
90
Comburent air-flow at Qn
kg/sec
0,022
0,034
0,045
0,055
0,065
0,080
Dimensions (h x w x d)
mm
850x450x621
850x450x693
850x450x801
850x450x871
850x450x1024
850x450x1132
Net weight
kg
60
68
75
83
95
103
Natural Gas/CPG
Natural Gas/CPG
Natural Gas/CPG
Natural Gas/CPG
Natural Gas/CPG
Natural Gas/CPG
Power consumption
Gas type
W
90
110
100
160
135
235
6,3
6,3
6,3
6,3
6,3
6,3
136
Dimensions
Power HT
RVA placement
Depth (A) mm
45 cm
45 cm/ 2 cm
45 cm/ 2 cm
137
Diagrams
The here below graphics, besides better defining the plan of the heating system, allow to deeply analyze the behaviour of the
generator in different use conditions.
The load loss of the exchangers defines the difference of pressure, in mm of water column, between the flow and return
connections of the generator. The flow rate/ head curve explains the dynamic features of the BAXI circulator used as accessory
in these boilers. The performance curve presents the changing in the efficiency, as ratio between the output and input of the
condensing boiler , according to the return temperature of the boiler.
Finally the last graphic explains the flue temperature trends of the boiler according to the return temperature.
HEAD (mH20)
45 kW
65 kW
5,5
5,0
4,5
4,0
3,5
3,0
2,5
2,0
1,5
1,0
0,5
85 kW
100 kW
2000
3000
4000
5000
112-120 kW
150 kW
6000
108
107
106
105
104
103
102
101
100
99
98
97
Flues temperature %
30% load
100% load
30
35
40
45
50
55
138
60
75
70
65
60
55
50
45
40
35
30
100% load
30% load
30
35
40
45
50
55
60
Burner-exchanger unit
The pre mixing air-gas unit, the burner and the primary exchanger are the components that allow these condensing boilers to
offer high performances.
The pre mixing unit is made of the Venturi pipe in the fan inlet and of the mixer that grant constantly to the burner an optimal
air-gas ratio independently from the number of turns of the fan limiting to the minimum the consumptions and ensuring always
the correct combustion (that means reduction of the pollutant emissions).
The stainless steel burner, through the internal spreader and the special micro-perforation of the cylindrical surface, grants a
uniform spread of the air-gas mixture independently from his length.
The primary exchanger, totally made of stainless steel, is built with two cylindrical flue chambers, vertically positioned (burner
chamber and condensation chamber). Inside the cylindrical surface there are stainless steel coils, in which run the water of the
primary circuit. In the upper chamber the warm flues discharge gives heat to the return water of the system, contained in the
coils, provoking the condensation of the flues themselves and giving latent heat to the water, pre-heating it before it enters the
chamber of the burner.
Flue outlet
Power HT 85-100
Power HT 45-65
Flue outlet
Primary
exchanger
Primary
exchanger
Condensation
chamber
Condensation
chamber
Burner
Burner
fan
Chamber of
the burner
Chamber of
the burner
Coils
Coils
fan
Power HT 120-150
venturi-mixer
unit
Flue outlet
venturi+mixer
unit
Primary
exchanger
Condensation
chamber
Burner
venturi-mixer
unit
Chamber of
the burner
Coils
fan
139
br bk b y/g
2 1
2 1 2 1
br
y/g
br
2 1
2 1 2 1
b b br b b br
11 12 13 14 15 16 17
br b
b br
MAINS POWER
TERMINAL BOARD
FUSE
2 3
PROGRAMMABLE
OUTPUT 230 V
br b br b br b
MAIN INPUT
FAN
1 2 4 5
y/g
y/g
b
br
1 2
br b y/g
2 3
CENTRAL HEATING
SYSTEM PUMP
CONNECTION POINTS
GAS VALVE
FUMES
THERMOSTAT
X30
SAFETY
THERMOSTAT
FLAME SENSING
ELECTRODE
X40
MIN
I X1-01 I X1-02 I
OUT
IN
DOMESTIC HOT
WATER PUMP
CONNECTION POINTS
DISPLAY
X50
V2
V1
2 1
2 1 2 1
b b bk bk r r
2 1
LN
MC
G/V
1
2
3
4
5
6
7
8
9
10
IGNTER
nn
NTC RETURN
HEATING SENSOR
b
y/g
bk br
HYDRAULIC
PRESSURE
SENSOR
OUTDOOR SENSOR
SAFETY SHUT-DOWN
ROOM THERMOSTAT
REMOTE CONTROLLER
CONNECTION
NTC DELIVERY
HEATING SENSOR
X11
12
11
10
9
8
7
6
5
4
3
2
1
X12
6
5
4
3
2
1
rr
X15
X14
X13
5
4
3
2
1
IGNITION
ELECTRODE
g g br br
2 1 2
CLIP-IN MODULE
TO CONTROL THE
MIXING ZONE
3
2
1
COM
140
NO
INTERFACE BUS
FOR BOILERS IN
CASCADE
Wiring diagram
2 1 2 1
FUSE
MAIN INPUT
FAN
1 2 4 5
2 1
y/g
br
br
2 1
2 1 2 1
230V - 50Hz
PS
b b br b b br
11 12 13 14 15 16 17
br b
b br
2 3
PROGRAMMABLE
OUTPUT
br b br b br b
br bk b y/g
y/g
y/g
y/g
b
br
1 2
br b y/g
2 3
CENTRAL HEATING
SYSTEM PUMP
CONNECTION POINTS
DOMESTIC HOT
WATER PUMP
CONNECTION POINTS
GAS VALVE 1
FUMES
THERMOSTAT
X30
SAFETY
THERMOSTAT
FLAME SENSING
ELECTRODE
X40
DISPLAY
G/V
GAS VALVE 2
18 19 20
X50
2 1
2 1 2 1
b b bk bk r r
2 1
G/V
SPARK
GENERATOR
b
y/g
bk br
WATER
PRESSOSTAT
OUTSIDE SENSOR
SAFETY SHUT-DOWN
ROOM THERMOSTAT
REMOTE CONTROLLER
CONNECTION
br - brown
bk - black
b - blue
r - red
g - green
g/y - green/yellow
w - white
1
2
3
4
5
6
7
8
9
10
CENTRAL HEATING
TEMPERATURE SENSOR
g g g
X11
12
11
10
9
8
7
6
5
4
3
2
1
rr
X15
X14
X13
X12
6
5
4
3
2
1
IGNITION
ELECTRODE
LN
MC
g g br br
2 1 2
CLIP-IN MODULE
TO CONTROL THE
MIXING ZONE
4
3
2
1
COM
I X1-01 I X1-02 I
AIR IN
OUT
L OT
PI
L OT
PI
IN
AIR IN
OUT
IN
3
2
1
NO
INTERFACE BUS
FOR BOILERS IN
CASCADE
Wiring diagram
141
142
143
Flue pipes
Power HT, open flue range of boilers, are certified for a B23 type of installation. This means that the boiler has to be connected
to a chimney through a stainless steel or plastic pipe with an internal diameter of 80 mm (Power HT 1.450 and Power HT 1.650)
or internal diameter 100 mm (Power HT 1.850-1.1000-1.1200-1.1500). There are available accessories in smooth PP with a
80 mm and 110 mm diameter. To use 110 mm flue accessories made of PP it is necessary to use an adaptor 100/110 available,
as well, as optional.
Important: the horizontal stretches must have a slope towards the boiler of 3.
Model
HT 1.450
HT 1.650
HT 1.850
HT 1.1000
HT 1.1200
HT 1.1500
30
20
20
20
20
20
For each 90 bend installed the length For each 45 bend installed the length
decreases of (m)
decreases of (m)
1
1
1
1
1
1
0,5
0,5
0,5
0,5
0,5
0,5
P available with
Flue pipe B23 100
P available with
Single clapet 110/110
P available with
Double clapet 110/110
150
150
110
150
170
280
80
120
Dual
flue
system
accessories
45-65 kW
Picture
Description
Code
LSB 710000100
KHG 714059411 .
KHG 714059910 .
710718301 .
PP 90 bend 80
KHG 714059211 .
PP 45 bend 80
KHG 714059311 .
KHG 714037411 .
KHG 714106110 .
KHG 714037310 .
KHG 714018510 .
KHG 714018411 .
Flue terminal 80
LSD 790000150 .
KHG 714010410 .
145
Picture
Description
Code
KHG 714105710 .
PP flexible pipe 80 L= 20 m
KHG 714105810 .
KHG 714105910 .
KHG 714106010 .
KHG 714106210 .
KHG 714111210 .
146
Description
Code
LSB 710000110
LSB 710000120
KUG 714133210 .
KUG 714133110 .
710718501 .
KHW 714096910 .
PP 90 bend 110
KUG 714133010 .
PP 45 bend 110
KUG 714132910 .
Electronics
Power HT range of boilers is provided with a wide digital control panel: dedicated push-buttons for each single function and LCD
display combining symbols and codes for information about the boiler working status allowing an easy reading and an immediate
parameter control, programming and setting.
Microprocessor with double CPU: a new technology software for the boiler optimal operation
Built-in daily timer to program both central heating and DHW functions
Programmable pre-heating function of the DHW circuit to reduce waiting times
Digital electronic thermometer
Self-check: detection and description of any possible fault
Built-in climatic regulation (outdoor sensor supplied as optional)
Automatic summer/winter switch with outdoor sensor connected
Cascade system installation option
Mixing systems (high and low temperature) installations option
Interface PCB, available as optional, connectable for supplementary functions such as remote control of fault/operation
signals, control of additional pumps, control of boiler output by an external electronic device, etc.
Setting
heating
mode
DHW
ON-OFF
Heating
temperature
regulation
Information:
-DHW temperature
-Outside temperature
(if connected to the
outdoor sensor)
DHW temperature
regulation
Reset
Programmes
access
and shift
Programmes
access
and shift
Parameters
regulation
(increase value)
Parameters
regulation
(decrease value)
147
148
Model
Description
Code
KHG 714077913 .
KHG 714107612 .
KHG 714072612 .
Outdoor sensor
KHG 714072811 .
KHG 714078112 .
KHG 714078013 .
KHG 714078212 .
Dimensions
936,5
136,5
800
986,5
186,5
850
800
400
678,5
526
524
149
Single installation
Shut-off valve
Non-return valve
Extension vessel hydraulic connection
Shut-off valve
Safety valve
Flow manifold
150
Single installation
Manifold pipes single boiler/last boiler
Power HT models
Code
45-150 kW
KHW 714104210 .
Flow manifold
Return manifold
45-150 kW
Code
KHW 714098611 .
45-150 kW
Code
KHW 714104311 .
151
After removing the cover of the control panel, mount the plate (B) supplied with the bus interface, and so mount the accessory as
well (C). The flat cable (A) have to be linked to the connector X40 of the electronics of the boiler. Connect the wiring (respecting
the polarity) between the connector X41 of the bus interface and the connector MB-DB of the controller.
Note: to make the connection easy between the accessory and the PCB, connect the wiring (A) to the PCB before fixing the plate
(B). To allow the mounting of the cover of the control panel it is necessary to cut the two plastic pins which are on the cover just
next to the bus interface.
Bus interface for climatic
regulators for boilers in cascade
152
mmH2O
mbar
Manometro
OCI 420
10
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
bar
20
60
80
100
120
QAD
TERMOMETRO
40
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
SYSTEM MADE OF 1 HIGH OUTPUT CONDENSING BOILER POWER HT, 1 DIRECT HIGH TEMPERATURE
CIRCUIT, 1 LOW TEMPERATURE MIXING CIRCUIT, 1 TANK FOR THE SOLAR INTEGRATION (OPTION)
20
Manometro
10
20
60
C
TERMOMETRO
40
80
100
120
153
OCI 420
MB - DB
DN 50
20
60
TERMOMETRO
40
100
120
80
60
TERMOMETRO
40
80
100
120
7
20
20
60
C
TERMOMETRO
40
60
C
TERMOMETRO
40
80
100
100
120
80
120
20
20
60
TERMOMETRO
60
TERMOMETRO
40
40
100
100
120
80
120
80
10
Allo
scarico
9
RVA 46
MB/DB
Y1/Y2
M/B1
20
60
80
100
120
QAD
TERMOMETRO
40
20
60
C
TERMOMETRO
40
100
120
80
RVA 46
M/B1
20
60
80
100
120
QAD
TERMOMETRO
40
20
60
C
TERMOMETRO
40
100
120
80
ECO
All'impianto di Riscaldamento
Q2
12
15
11
20
60
C
TERMOMETRO
40
100
120
80
Alle Utenze
SYSTEM MADE OF 1 HIGH OUTPUT CONDENSING BOILER POWER HT, 1 PIPE IN TANK CYLINDER FOR HEATING AND
DHW PRODUCTION INTEGRATION
mmH2O
mbar
Manometro
20
14
MB/DB
13
Q2
154
Y1/Y2
mmH2O
mbar
Manometro
20
60
C
TERMOMETRO
40
100
120
80
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
QAZ 21
20
60
C
TERMOMETRO
40
80
100
120
SYSTEM MADE OF 1 HIGH OUTPUT CONDENSING BOILER POWER HT, 1 HIGH TEMPERATURE DIRECT CIRCUIT, 1 TANK
1
2
3
4
5
6
7
8
155
156
AGU 2.500
tor
llec
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
Manometro
bar
20
60
80
100
120
QAD
TERMOMETRO
40
ts
Fla
r
ola
20
60
C
TERMOMETRO
40
80
100
120
tor
llec
co
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
ECO
10
13
14
11
20
60
C
TERMOMETRO
40
80
100
120
SYSTEM MADE OF 1 HIGH EFFICIENCY CONDENSING BOILER POWER HT, 1 HIGH TEMPERATURE DIRECT CIRCUIT,
1 MIXING CIRCUIT, 1 TANK WITH INTEGRATION WITH SOLAR SYSTEM
mmH2O
mbar
Manometro
ola
ts
Fla
o
rc
12
QAZ 21
Dimensions
186,5
936,5
136,5
800
The distance between the boilers in cascade varies from 450 mm to 20 mm depending on manifold accessory used.
Flow/return manifolds squared 100x100 with flanges DN80 PN6
20
20
450
450
450
436,5
157
Cascade
installation
with Power HT boilers from 45 to 150 kW
Flue pipe kit for two boilers
From 160 to 200
Return manifold
Shut-off valve
Hydraulic connection
for 2nd pump
Non-return valve
3 way shut-off
valve
Safety valve
Flow manifold
Cascade installations
Manifold pipes single boiler/last boiler
Power HT models
Code
45-150 kW
KHW 714104210 .
Flow manifold
Return manifold
45-150 kW
Code
KHW 714104311 .
45-150 kW
Code
KHW 714098611 .
Code
45-150 kW
(45 cm between the boilers)
KHW 714099010 .
Flow manifold
Return manifold
45-150 kW
(2 cm between the boilers)
KHW 714103611 .
Flow manifold
Return manifold
159
2m
Remarks
Distance of the manifold from the first boiler to the vertical chimney: 2 meters
Shutter kit installed in each boiler in cascade
The flue pipes and the connections between the flue manifold of the cascade and the chimney are not supplied by BAXI
The manifolds in cascade over 200mm diameter are not supplied by BAXI
The calculation has been made assuming a PP "double wall" flue duct
160
HT
1.450
HT
1.650
HT
1.850
HT
1.1000
HT
1.1200
HT
1.1500
Nominal output
Total 80/60 C (kW)
90
130
170
200
240
300
125
125
160
160
160
160
125
125
160
160
160
200
125
125
160
160
200
200
125
125
160
160
200
200
Nominal output
Total 80/60 C (kW)
135
195
255
300
360
450
125
125
160
160
200
200
125
160
160
160
200
200
125
160
160
160
200
200
125
160
160
160
200
250
Nominal output
Total 80/60 C (kW)
180
260
340
400
480
600
125
160
160
160
200
200
160
160
160
200
200
250
160
160
200
200
200
250
160
160
200
200
200
300
Nominal output
Total 80/60 C (kW)
225
325
425
500
600
750
160
200
160
200
200
250
160
200
200
200
250
250
160
200
200
200
250
300
160
200
200
200
250
300
161
After removing the cover of the control panel, mount the plate (B) supplied with the bus interface, and so mount the accessory as
well (C). The flat cable (A) have to be linked to the connector X40 of the electronics of the boiler. Connect the wiring (respecting
the polarity) between the connector X41 of the bus interface and the connector MB-DB of the controller.
Bus interface for climatic
Note: to make the connection easy between the accessory and the PCB, connect
the wiring (A) to the PCB before fixing the plate
regulators for boilers in cascade
(B). To allow the mounting of the cover of the control panel it is necessary to cut the two plastic pins which are on the cover just
next to the bus interface.
162
Return sensor
Power 230V AC
Back view
TEMPERATURE
REGULATOR
FOR BOILERS
IN CASCADE
LINE
ENGINE
163
mmH2O
mbar
Manometro
CONT 1
CONT 1
5
1
OCI 420
OCI 420
CONT 2
14
CONT 2
14
QAD
9
10
CONT 1
CONT 1
MB/DB
M/B70
RVA 47
M/B3
6
QAD
10
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
CONT 2
14
CONT 2
14
20
60
C
TERMOMETRO
40
80
100
120
CONT 1
CONT 1
11
QAZ 21
12
CONT 2
14
CONT 2
14
CONT 1
CONT 1
13
20
60
C
TERMOMETRO
40
80
100
120
SYSTEM MADE OF 2 HIGH OUTPUT CONDENSING BOILERS POWER HT, 1 HIGH TEMPERATURE DIRECT CIRCUIT,
1 TANK WITH INTEGRATION WITH SOLAR SYSTEM (OPTION), BUILT-IN HEAT BOXES RH+2C
CONT 2
14
CONT 2
14
Q3
Q1
164
M/B10
OCI 420
OCI 420
12
QAD
M/B70
MB/DB
RVA 47
M/B3
M/B10
Q3
Q1
QAD
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
QAZ 21
10
11
20
60
C
TERMOMETRO
40
80
100
120
SYSTEM MADE OF 2 HIGH OUTPUT CONDENSING BOILERS POWER HT, 1 HIGH TEMPERATURE DIRECT CIRCUIT,
1 TANK WITH INTEGRATION WITH SOLAR SYSTEM (OPTION)
mmH2O
mbar
Manometro
20
165
OCI 420
OCI 420
OCI 420
QAD
12
M/B70
MB/DB
RVA 47
10
M/B3
M/B10
Y1/Y2
Q2
M/B1
M/B1
MB/DB
QAD
12
RVA 46
11
RVA 46
11
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
12
20
60
80
100
120
QAD
TERMOMETRO
40
20
60
C
TERMOMETRO
40
80
100
120
12
20
60
80
100
120
QAD
TERMOMETRO
40
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
13
QAZ 21
Manometro
bar
Manometro
bar
14
15
20
60
C
TERMOMETRO
40
80
100
120
SYSTEM MADE OF 3 HIGH OUTPUT CONDENSING BOILERS POWER HT, 2 HIGH TEMPERATURE DIRECT CIRCUITS,
1 TANK WITH INTEGRATION WITH SOLAR SYSTEM (OPTION)
mmH2O
mbar
Manometro
4
Q3
Q1
Y1/Y2
166
Q2
mmH2O
mbar
Manometro
OCI 420
OCI 420
OCI 420
11
QAD
MB/DB
M/B70
RVA 47
QAD
Manometro
bar
20
60
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
20
60
C
TERMOMETRO
40
80
100
120
10
10
10
10
SYSTEM MADE OF 3 HIGH OUTPUT CONDENSING BOILERS POWER HT, 1 HIGH TEMPERATURE DIRECT CIRCUIT,
BUILT-IN HEAT BOXES RS2Z
10
M/B10
10
bar
10
Manometro
10
Q1
167
Hydraulic separator
For the theoretical explanation of the hydraulic separator see pages from 73 to 77
330
811
484
143
290
203
203
290
484
811
398
1069
230
157,5
300
399
300
157,5
365
484
290
95
95
95
290
484
450
264,5
1279
263
450
1279
365
450
263
1279
l/h
56
kcal/h
da 201.000 a 300.000
kW
234-349
bar
5-40
Kg
Next recharges
Kg
4,5
Dimensions (hxwxd)
mm
260x330x225
168
264,
Other
accessories
Flue accessories for Power HT cascade installation
Picture
Description
Code
710715201 .
710715601 .
710716301 .
710716401 .
PP 90 bend 160
KHW 714097810 .
PP 90 bend 200
KHW 714098210 .
KHW 714097710 .
KHW 714098110 .
Other
accessories
Flue accessories for Power HT 45-65 kW cascade installation
Picture
Description
Code
710716801 .
710717701 .
710682001 .
PP 90 bend 125
KHG 714094410 .
KHG 714094510 .
KHG 714094610 .
169
Other
accessories
Flue accessories for Power HT 85-150 kW cascade installation
Picture
Description
PP shutter kit 110/110 with condensing trap
Code
710682101 .
KHW 714096910 .
Hydraulic accessories
for single installation
Picture
Description
Code
KHW 714104210 .
KHW 714104311 .
KHW 714098611 .
Hydraulic accessories
for cascade installation
Picture
170
Description
Code
KHW 714104210 .
KHW 714104311 .
KHW 714098611 .
KHW 714099010 .
KHW 714103611 .
Other
accessories
Thermoregulation
Picture
Description
Code
KHG 714078410 .
KHG 714096610 .
KHG 714078511 .
Mixing valve G1
KHG 714078310 .
KHG 714078610 .
KHG 714078710 .
KHG 714078810 .
KHG 714078910 .
KHG 714079010 .
KHG 714076810 .
171