You are on page 1of 40

Data sheet 10/23-5.10 EN Rev.

10

System components for sample gas sampling


Probe tubes, filter units, sample gas lines, accessories

Measurement made easy

Modular sample gas probe system

Type 60 Probe tube (cement flue gas probe)

FE2 Filter unit

Probe 2

Annular heating element

Probe 11

Heating sleeve

Ceramic filter

PFE2 Filter unit

Process pressure reducers

PFE3 Filter unit

CGWB 13 Heated sample gas line

Type 40, Type 40 W Probe tubes

TBL 01-S, TBL 01-C, TBL 01-E Heated sample gas lines

Type 42 Probe tube (heated)

Electronic temperature controller and switching relay

Modular sample gas probe system


Easily adaptable to different sampling conditions thanks
to modular construction

Components:

FE2, PFE2, PFE3 filter units


Probe tube types 40, 42, 60
Annular heating element
Heating sleeve

Probe tubes and filter unit heatable


Connections for test gas and back purging
Filter with high retention rate and long service life
Easy filter replacement
Usable in emission measuring systems conforming to
European Directives 2000/76/EC and 2001/80/EC

System components for sample gas sampling

10/23-5.10 EN Rev. 10

FE2 Filter unit


Use
The FE2 filter unit is a component of the modular gas sampling
probe system. It is used for filtering gases containing dust.

Process gas sampling conditions


Pressure
pabs = 50 to 600 kPa
Temperature
Max. 200 C (coated max. 180 C)
Flow rate
30 to 500 l/h, relative to 100 kPa and 0 C
Pressure drop
Approx. 0.6 hPa at 100 l/h
Dust content
Max. 3 g/m3 (application recommendation);
max. 40 g/m3 with probe tube type 40 (see page 20) with
purge-back device;
max. 2000 g/m3 with probe tube type 60 (see page 22)

Filter characteristics

Connection ports

Filter element
Surface filter

Sample gas , test gas


G 1/4 in. internal thread

Filter fineness
0.3 m

Compressed air for back-purging (2 ports, optional)


G 1/2 in. internal thread

Retention rate
99.98 %

Probe tube
G 3/4 in. internal thread

Seal integrity
104 hPa l/s

Compressed air supply for back-purging

Dead volume
280 ml

(see PFE2 filter unit, page 7)

Materials of gas-conducting parts

Instrument air
Free of dust, water and oil
Pressure
Max. 600 kPa

Casing and connections


Special steel 1.4571 (SAE 316Ti)
Flange
Special steel 1.4541 (SAE 321)

Dimensional drawing (dimensions in mm)

Filter
Aluminum oxide surface filter

105

14

130

160
65

Coating
Thermoset plastic, resistant up to 180 C

Installation
Flange
DN 65, PN 6, form B to DIN 2573, flange gasket A;
positioning of holes:
45, 90, 135, 180, 225, 270, 315, 360

280

40...65

Mounting
Flange connect or bolt to the probe tube
Weight
Approx. 8.0 kg

10/23-5.10 EN Rev. 10

System components for sample gas sampling

FE2 Filter unit


Ordering information
Housing and flange SS, filter 0,3 m ceramic, gaskets standard, without purge connectors
Housing and flange SS, coated, filter 0,3 m ceramic, gaskets standard, without purge connectors
Housing and flange SS, filter 0,3 m ceramic, gaskets standard, with purge connectors
Housing and flange SS, coated, filter 0,3 m ceramic, gaskets standard, with purge connectors
Housing and flange SS, filter 0,3 m ceramic, gaskets for high corrosive gases, without purge connectors
Housing and flange SS, coated, filter 0,3 m ceramic, gaskets for high corrosive gases, w/o purge connectors
Housing and flange SS, filter 0,3 m ceramic, gaskets for high corrosive gases, with purge connectors
Housing and flange SS, coated, filter 0,3 m ceramic, gaskets for high corrosive gases, with purge connectors

System components for sample gas sampling

Catalog No.
23042-4-0730743
23042-5-0730744
23042-4-0730745
23042-5-0730746
23042-4-0730747
23042-5-0730748
23042-4-0730749
23042-5-0730750

10/23-5.10 EN Rev. 10

Annular heating element


Use
The annular heating element is used for heating the FE2 filter
unit, which is a component of the modular gas sampling probe
system (see page 3).
Heating is necessary if condensation is likely from moist gases
and there is consequently risk of the filter becoming clogged
and corroded.

Data
Power supply
120 V AC or 230 V AC, 50 to 60 Hz
Heater output
200 W, 100 W or 50 W depending on setting (see below)
The heating resistors are factory-set for heat output of 100 W
Temperature of heater (unregulated)
Approx. 120 C to 180 C (measured at ambient temperature
of 20 C, still air)
Ambient temperature
0 to 55 C (still air)
Degree of protection of housing
IP50

Dimensional drawing (dimensions in mm)

Materials
Housing: aluminum alloy, heating surface: brass
Weight
Approx. 1.7 kg
Electrical connections
Terminals via M20 cable gland. The electrical supply
conductor must be heat resistant ( 200 C).

Installation
Two half shells are placed round the FE2 filter unit to be heated
and closed with a wing screw.

Option
Regulated heating with 1 x Pt 100

Ordering information

Heating circuit

Ring heater 230 V, 50/60 Hz


Ring heater 120 V, 50/60 Hz
Ring heater with Pt 100, 230 V, 50/60 Hz
Ring heater with Pt 100, 120 V, 50/60 Hz

230 / 115 V AC
200 W

10/23-5.10 EN Rev. 10

230 / 115 V AC
100 W

Catalog No.
23029-5-7865312
23029-5-8008813
23029-5-7865316
23029-5-7865317

230 / 115 V AC
50 W

System components for sample gas sampling

Heating sleeve
Regulated heating sleeve for FE2 filter unit
Heater
Micanite
Holding temperature
Max. 350 C
Temperature control
Max. 200 C (Pt 100)
Power supply
120 V AC or 230 V AC
Power consumption
250 VA
Connection
Terminal box with M16 cable gland,
degree of protection IP54
Supply cable
3 x 1 mm2 with silicone sheath, length 1 m
Ambient temperature
20 to +45 C
Relative humidity
75 % yearly mean; infrequent slight condensation
permissible
Weight
Approx. 1 kg

Essential accessories

Ordering information
Heated sleeve, 230 V, 50/60 Hz, 250 VA
Heated sleeve, 120 V, 50/60 Hz, 250 VA
Isolation for heated sleeve

Catalog No.
23043-5-8018410
23043-5-8018411
23043-5-8018412

Insulating mat
Temperature controller (see page 39)

System components for sample gas sampling

10/23-5.10 EN Rev. 10

PFE2 Filter unit


Design
The PFE2 filter unit consists of the FE2 filter unit with a regulated heating sleeve, installed in a special-steel protective case. It
is used to filter dust-containing gases and is a component of
the modular gas sampling probe system.
When used for gases with high dust content, the PFE2 can
optionally be fitted with valves for automatic cleaning of the
filter element in the FE2 filter unit. Depending on the dust load,
in addition to 1-stage or 2-stage back-purging the type of
back-purging can be selected.
For this purpose, a pneumatically controlled valve circuitry with
diaphragm back-purging valves and a direct acting version with
coaxial sliding valves are available. The coaxial sliding valves
are particularly suitable for frequent back-purging cycles.

FE2 filter unit


Technical data see page 3

Protective case
Dimensions
Standard version: 450 x 450 x 400 mm (H x W x D)
Basic version: 270 x 203 x 330 mm (H x W x D)
Material
Special steel 1.4301 (SAE 304)
Degree of protection of housing
IP54
Weight
Standard version: approx. 25 kg incl. FE2 filter unit
Basic version: approx. 17 kg incl. FE2 filter unit
Ambient temperature
20 to +45 C

Options
Annular heating element, unregulated (see page 5)
Heating sleeve, regulated (Pt 100), with insulating mat
(see page 6)

Back purging
Pneumatic valves
Type
2/2-way straight-way diaphragm valve
Operating pressure / control pressure
600 kPa (6 bar)
Nominal diameter
DN 12
Connections
G 1/2 in. internal thread,
control air: G 1/8 in. internal thread
Material
Brass
Mode of operation
Closed in normal position
Ambient temperature
0 to +100 C

10/23-5.10 EN Rev. 10

Control valves
Type
3/2-way solenoid valve
Pressure range
600 kPa (6 bar)
Nominal diameter
DN 2.0
Connections
G 1/8 in. internal thread
Material
Brass
Mode of operation
Closed in normal position
Ambient temperature
0 to +100 C
Electrical connections
Standard connector
Power supply
120 V AC or 230 V AC, 50 to 60 Hz
Power consumption
8 VA
Coaxial valves
Type
2/2-way direct acting valve
Operating pressure
064 bar
Nominal diameter
DN 10
Connections
10/12 x 1 mm
Material
Body: brass, valve seat: synthetic resin on metal, seal: NBR
Mode of operation
Closed in normal position
Ambient temperature
10 to +80 C
Power supply, current consumption
230 V AC, 50 to 60 Hz, 0.13 A

System components for sample gas sampling

80

165

11,5

6,5

450

50 80

M4

19,5

65
210

M4

75

180
155

110

2x M32
3x M25
2x M20

System components for sample gas sampling


400

300

170

160

Take holes for cable glands on the left


into account
Terminal box with cable glands
Use as required

450

90

155

M4

M4

450

80

Flange plate with pipe clamp


2 1/2" RST 37-2 hot galvanized DIN 3568
for mounting at probe mounting adapter

Elongated holes for


M8 safety collar bolts

Compressed air
Purging
Bulkhead fitting 10/12x1 mm
Test gas connection
Bulkhead fitting 4/6x1 mm
Control air
Bulkhead fitting 4/6x1 mm

Sample gas connection

Cover swivels upwards

Electrical connections

550
300

8
155

75

PFE2 Filter unit

Probe protective case, standard version: Dimensional drawing (dimensions in mm)

17

10/23-5.10 EN Rev. 10

440

PFE2 Filter unit


Probe protective case, standard version: Mounting
Minimum distance xmin of the mounting
flange from the wall depending on mounting
angle :

10 15 20 25 30 35
xmin / mm 229 248 268 287 307 324

Probe protective case, basic version: Dimensional drawing and gas connections (dimensions in mm)
1
2
3
4

330

Terminal box -X1 IP66


Sample gas line
Sample gas connection 6 mm
Test gas connection bulkhead fitting
6 mm

266

270

200

80

130

2x
M20x1.5

58

3x
2x
M20x1.5 M12x1.5
124

10/23-5.10 EN Rev. 10

3 2

System components for sample gas sampling

10

Solenoid Valve Aeration


-Y4

Diaphragm Valve
Cleaning Filter Surface and Probe Tube
-Y3.2

Pilot Operation Valve


Cleaning Filter Surface and Probe Tube
-Y3.1

Junction Box

Protection Box

System components for sample gas sampling


Power Supply

Heated
Check Valve
-Y5

Filter Unit

Heated Sample Line


-E2

Pt100 Connection

Check Valve

Control Air Inlet


Bulk Head Union 6 mm

Calibration Gas Inlet


Bulk Head Union 6 mm

Instrument Air Inlet


Bulk Head Union 12 mm

Diaphragm Valve
Puls-Instrumentenluft
-Y1.2

Pilot Operation Valve


Puls-Instrument Air
-Y1.1

Diaphragm Valve
Cleaning Filter
-Y2.2

Pilot Operation Valve


Cleaning Filter
-Y2.1

A:

Calibration Gas Inlet


G 1/4" -> 6 mm Tube Fitting

D:

Sample Outlet
G 1/4" -> 6 mm or 8 mm Tube Fitting

C:

Back Pressure Purging Filter Surface


and Probe Tube Inlet
G 1/2" -> 12 mm Tube Fitting

B:

Back Pressure Purging Filter Inlet


G 1/2" -> 12 mm Tube Fitting

PFE2 Filter unit

Pneumatic connections for 2-stage back-purging, standard version

10/23-5.10 EN Rev. 10

10/23-5.10 EN Rev. 10

System components for sample gas sampling


Power supply

Connection for instrument


air (max. 6 bar)
bulkhead fitting 12 mm

Heated cutoff valve -Y5 (option)

Solenoid valve for


cleaning filter surface
and probe tube -Y1

Filter unit

Connection for back-purging


filter surface and probe tube
G 1/2 in. to 12 mm pipe coupling

Protection box
Junction box

Heated sample gas line -E2

Connection for Pt100

Connection for test gas


bulkhead fitting 6 mm

Connection for instrument


air (max. 6 bar)
bulkhead fitting 12 mm

Solenoid valve for


cleaning filter -Y2

Sample gas outlet G 1/4 in.


to 6 mm pipe coupling

Connection for back-purging filter


G 1/2 in. to 12 mm pipe coupling

Check valve

Test gas connection G 1/4 in.


to 6 mm pipe coupling

PFE2 Filter unit

Pneumatic connections for 2-stage back-purging, standard version with coaxial valves

11

PFE2 Filter unit


Probe protective case, standard version: Circuit and terminal diagram
Protection Box

External

Junction Box

Analyzer Cabinet

-X1

1
N

2
PE

3x1,5 mm

-X1

3x2,5 mm

Heating
Sleeve
Filter Unit

Heated
Sample Line

-E1

Power Supply Heating Sleave Filter Unit,


230 or 115 VAC, 50...60 Hz, 250 W,
required fusing 6 A,
controller required !

-E2

J
N

7
PE

3x1,5 mm

9
10

-E3.1

21.10.2005

Power Supply Sample Line,


230 VAC: < 35 m -> 1~, > 35...60 m -> 3~,
115 VAC: < 15 m -> 1~, > 15...40 m -> 3~,
50...60 Hz, 90 W/m,
in case of a 3~ sample line connect
L2 -> Termination 5, L3 -> Termination 6,
required fusing 16 A,
controller required !

J
N

-E3.2

Power Supply Heater Probe Tube,


230 VAC, 50...60 Hz, max. 800 W,
required fusing 6 A,
in case of 115 VAC power supply wire the
heating elements -E3.1 and -E3.2 parallel.
controller required !

11
PE

12

-X1

3x1,5 mm

-B01
set @ 30C

3x1,5 mm

13
N

14
PE

15

-E4

Frost Protection

Heated
Probe Tube

Power Supply Frost Protection,


230 or 115 VAC, 50...60 Hz, 300 W,
required fusing 6 A

-X1
L

16
N

17
PE

18
19

-E5.2

Heated Check
Valve

-E5.1

Power Supply PTC-Elements and


Powerpack -G02 / Heated Solenoid Valve
in Sample Outlet,
230 or 115 VAC, 50...60 Hz, 250 W,
required fusing 6 A

20
21

-T01

4x1,5 mm

115 V~
24 V=
1,3 A

-X2

3x1,5 mm

-Y3.1

2
PE

Power Supply Pilot Operation Valve -Y3.1,


Cleaning Filter Surface and Probe Tube,
230 or 115 VAC, 50...60 Hz, 8 W
required fusing 1 A

...

-Y1.1

5
PE

Power Supply Pilot Operation Valve -Y1.1,


Puls-Instrument Air,
230 or 115 VAC, 50...60 Hz, 8 W
required fusing 1 A

...

-Y2.1

...

PE

Power Supply Pilot Operation Valve -Y2.1,


Cleaning Filter,
230 or 115 VAC, 50...60 Hz, 8 W
required fusing 1 A

10

-Y4

11
12

PE

Power Supply Pilot Operation Valve -Y4,


Aeration,
230 or 115 VAC, 50...60 Hz, 8 W
required fusing 1 A

-Y5

-X2

13

A1

A2

-K01

14
15

PE

3x1,5 mm

Power Supply Relais -K05/


Check Valve -Y5,
230 or 115 VAC, 50...60 Hz,
required fusing 1 A

3...18
x 0,14 mm

-X3

2x0,14 mm

2x0,14 mm

Resistance Thermometer PT100,


Filter Unit Sample Outlet,
3-Wire-Connection

3
4
5

Resistance Thermometer PT100,


Sample Line,
3-Wire-Connection

6
7
8
9

2x
0,14 mm

10 11 12 13 14 15 16 17 18

2x
0,14 mm

2x0,14 mm

2x0,14 mm

12

Resistance Thermometer PT100,


Probe Tube,
3-Wire-Connection

System components for sample gas sampling

Resistance Thermometer PT100,


Filter Unit Sample Outlet (Safety Wiring), 3Wire-Connection
Resistance Thermometer PT100,
Sample Line (Safety Wiring),
3-Wire-Connection
Resistance Thermometer PT100,
Probe Tube (Safety Wiring),
3-Wire-Connection

10/23-5.10 EN Rev. 10

PFE2 Filter unit


Probe protective case, standard version with coaxial valves: Circuit and terminal diagram
Protection Box

External

Junction Box

Analyzer Cabinet

-X1

PE

-E1

-X1

3x1,5mm
5x2,5mm

Heating
Sleeve
Filter Unit

Heated
Sample Line

Power Supply Heating Sleave Filter Unit,


230 VAC, 50...60 Hz, 250W,
required fusing 6 A,
controller required!

L1 L2

L3

-E2

Power Supply Sample Line,


230 VAC, 50...60 Hz,
90 W/m, max. 11 kW / 17 kW,
required fusing 16 A / 25 A,
controller required!

PE

3x1,5mm

-E3.1

10

11

-X1

3x1,5mm

-B01

set@30C

13

N
PE

14 15

-E4

Frost Protection

Heated
Probe Tube

3x1,5mm

12

PE

-E3.2

Power Supply Heater Probe Tube,


230 VAC, 50...60 Hz, max. 800 W,
required fusing 6 A,
controller required!

Power Supply Frost Protection,


230 VAC, 50...60 Hz, 300 W,
required fusing 6 A

-X1
L

16

18 19

PE

17

230 V~

-T01

4x1,5mm

20

Heated Check Valve

-E5.1 -E5.2

Power Supply PTC Elements and Powerpack -G02/


Heated Solenoid Valve in Sample Outlet,
230 VAC, 50...60 Hz, 250 W,
required fusing 6 A

24V=
1,3A

-X2

...

-Y1

PE

...

-Y2

PE

...

Power Supply Solenoid Valve -Y2


Cleaning Filter,
230 VAC, 50...60 Hz, 30 VA
required fusing 1 A

-Y5

-X2

A1

A2

-K05

PE

3x1,5mm

-X3

2x0,14mm
2x0,14
mm

2x0,14mm

2x0,14mm

2x0,14
mm

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

2x0,14mm

10/23-5.10 EN Rev. 10

Power Supply Solenoid Valve -Y1


Cleaning Filter Surface and Probe Tube,
230 VAC, 50...60 Hz, 30 VA
required fusing 1 A

System components for sample gas sampling

Power Supply Relay -K05


for Cutoff Valve -Y5,
230 VAC, 50...60 Hz,
required fusing 1 A

Resistance Thermometer Pt100,


Filter Unit Sample Gas Outlet,
3-Wire Connection
Resistance Thermometer Pt100,
Sample Gas Line,
3-Wire Connection
Resistance Thermometer Pt100,
Probe Tube,
3-Wire Connection
Resistance Thermometer Pt100,
Filter Unit Sample Gas Outlet (Safety Wiring),
3-Wire Connection
Resistance Thermometer Pt100,
Sample Gas Line (Safety Wiring),
3-Wire Connection
Resistance Thermometer Pt100,
Probe Tube (Safety Wiring),
3-Wire Connection

13

PFE2 Filter unit


Ordering information
Catalog No. 23028-0
Design
with protection box, Standard, IP 54 (450 x 450 x 400 mm)
with protection box, Standard, IP 54, anti-freeze heating
with protection box, Standard, IP 54, ambient temp. max. 65 C
with protection box, Basic, IP 54 (270 x 203 x 330 mm)

2
3
4
5

Filter housing and flange (equal FE2)


Material SS, filter ceramic < 0.3 m, w/o connectors for back purging
Material SS, coated, filter ceramic < 0.3 m, w/o connectors for back purging

A
B

Heating
with heating sleeve and insulation (max. 190 C, Pt 100 required)
with ring heater, unregulated

2
3

Controlling and monitoring


without
with 1 x Pt 100
with 2 x Pt 100

1
2
3

Back purging unit with test/emergency purge valve (w/o compressed air unit)
without
with back purging, 1-stage and SS connection adapter
with back purging, 2-stage and SS connection adapter
without back purging, with test/emerg. purge valve, unheated, without SS connection adapter
with back purging, 1-st., with test/emerg. purge valve, heated shut-off valve, SS connection adapter
with back purging, 2-st., with test/emerg. purge valve, heated shut-off valve, SS connection adapter
with back purging, 2-st., heated shut-of valve, SS connection adapter
with back purging, 1-stage via Coax valve, SS connection adapter
with back purging, 2-stage via Coax valves, SS connection adapter
w. back purging, 1-st. via Coax valve, with test/emerg. purge valve, heated shut-off-v., SS connection ad.
w. back purging, 2-st. via Coax valves, with test/emerg. purge valve, heated shut-off v., SS connection ad.
with back purging, 2-st. via Coax valves, heated shut-off valve, SS connection adapter

0
1
2
3
5
6
7
A
B
D
E
F

Power supply
230 V, 5060 Hz
120 V, 5060 Hz
120 V, 5060 Hz CSA, with AWG wiring

1
2
3

Approvals
without
GOST

0
1

Gaskets
Standard
for high corrosive gases

1
2

Connectors for back-purging at the filter housing (FE2)


without
with

0
1

Bulkhead unions (at the protection box)


metric
imperial (sample gas outlet in metric only)

1
2

Catalog No. 23028-0-

14

System components for sample gas sampling

10/23-5.10 EN Rev. 10

PFE3 Filter unit


Design
The PFE3 filter unit consists of a modified FE2 filter unit with a
self-regulating heater. It is installed in a stainless steel protective case.

Process gas sampling conditions


Pressure
pabs = 50 to 600 kPa
Temperature
Max. 200 C
Flow rate
30 to 500 l/h, relative to 100 kPa and 0 C
Pressure drop
Approx. 0.6 hPa at 100 l/h
Dust content
Max. 3 g/m3 (application recommendation)

Filter characteristics
Filter element
Surface filter

Installation

Filter fineness
0.3 m

Flange
DN 65, PN 6, form B to DIN 2527;
positioning of holes: 45, 135, 225, 315

Seal integrity
104 hPa l/s

Mounting
Flange connect or bolt to the probe tube

Dead volume
280 ml
Dimensions
50 / 20 x 135 mm

Connection ports

Heater

Test gas
Bulkhead fitting 6 mm (option)

Sample gas
Pipe fitting 6 mm

Type
Self-regulating heater (400 W)

Purge gas
Bulkhead fittings 18 mm (option)

Temperature
180 C (ambient temperature 20 C)

Probe tube
G 3/4 in. internal thread

Temperature alarm
Approx. 150 C
Power supply
120 V AC or 230 V AC, 50 to 60 Hz

Protective case
Dimensions
270 x 203 x 330 mm (H x W x D)

Options
Annular heating element (see page 5)
Heating sleeve (see page 6)

Material
Special steel 1.4301 (SAE 304)

Materials of gas-conducting parts

Degree of protection of case


IP54

Casing, flange and connections


Special steel 1.4571 (SAE 316Ti)

Weight
Approx. 17 kg incl. FE2 filter unit

Seals
FPM

Ambient temperature
20 to +45 C

10/23-5.10 EN Rev. 10

System components for sample gas sampling

15

16

266

Cleaning
Filter Surface
and Probe Tube,
Bulk Head Union
18 mm

M20x1,5

System components for sample gas sampling


124

3x
M20x1,5
2x
M12x1,5

Junction Box -X1


IP66

200

Cleaning Filter,
Bulk Head Union
18 mm

Tube, CU
15x1 mm

Tube, SS 316Ti,
6x1 mm

Calibration Gas
Bulk Head Union
6 mm

Tube, CU
15x1 mm

330

58

PFE3 Filter unit

Dimensional drawing, gas connections (dimensions in mm)

10/23-5.10 EN Rev. 10

130

270

80

PFE3 Filter unit


Circuit and terminal diagram
Protection Box

External

Junction Box

Analyser Cabinet

-X1

Heated Aluminium Forms


Filter Unit

Power Supply
Heated Aluminium Form Filter Unit,
230 or 115 VAC, 50...60 Hz, 250 W,
required fusing 6 A

2
PE

3x1,5 mm

PE

-E1.2

-E1.1

-E1.4

-E1.3

set @ 140C

-X1

3x2,5 mm

Heated
Sample Line

-E2

4
PE

PE

Power Supply Sample Line,


230 or 115 VAC, 50...60 Hz,
90 W/m, max. 3600 W / 5700 W,
required fusing 16 A / 25 A,
controller required !

-X1

2x0,14 mm

5
6

2x0,14 mm

Resistance Thermometer PT100,


Filter Unit Sample Outlet,
3-Wire-Connection

7
8
9

Resistance Thermometer PT100,


Sample Line,
3-Wire-Connection

10
11

Temperature Alarm,
Surface heated Aluminium Forms

12
13

2x0,2 mm

10/23-5.10 EN Rev. 10

System components for sample gas sampling

17

PFE3 Filter unit


Ordering information
Catalog No. 23046-0
Design
with protection box IP54 (330 x 203 x 270 mm)

Filter housing and flange in stainless steel


Filter unit < 0.3 m (filtration fineness), without purge connectors
Filter unit < 0.3 m, coated, without purge connectors
Filter unit FE2, < 0.3 m, with purge connectors, 2-stage
Filter unit FE2, coated, < 0.3 m, with purge connectors, 2-stage

4
5
6
7

Heating
with self regulated heating and temperature alarm (120 / 230 V AC)
with ring heater, unregulated
with heated sleeve (max. 190 C, Pt 100 required)

1
2
3

Controlling and monitoring


without
with 1 x Pt 100 (only for heated sleeve)
with 2 x Pt 100 (only for heated sleeve)

3
4
5

Connectors for back purging (without compressed air unit)


without
with bulkhead unions for back purging, 1-stage
with bulkhead unions for back purging, 2-stage

1
2
3

Power supply
230 V AC, 5060 Hz
120 V AC, 5060 Hz

1
2

Test gas / emergency purging valve


without
with, unheated, bulkhead union for connecting

1
2

Catalog No. 23046-0-

18

System components for sample gas sampling

10/23-5.10 EN Rev. 10

Probe tube type 60 R


water cooled 3)

Probe tube type 60 S


water cooled 3)

Probe system H
water cooled 3)

Probe 2
partly heated

Probe 2
heated

1)
1)

1)
1)

1)
1)

1)
1)

1)

1)

p. 22

p. 22

p. 22

p. 22

p. 23

p. 23

Probe tube type 42


SS heated

Probe tube type 40


silicon carbide

Probe tube type 40


SS 1.4893

Probe tube type 40


SS 1.4571 (SAE 316Ti)
coated

Probe tube type 60


water cooled 3)

< 130C
< 180C
< 300C
180450C
180900C
< 1300C
< 1400C
Dust content
< 50 mg/m3
< 1000 mg/m3
< 3 g/m3
> 3 g/m3
40100 g/m3
< 2000 g/m3
Water vapor
< 65 C
dew point
> 65 C
Acidic aerosols (acid dew pt. 130 C)
Pressure
< 2 bar
< 5 bar
Technical data see

Probe tube type 40 W


SS 1.4571 (SAE 316Ti)

Probe tube type 40


SS 1.4571 (SAE 316Ti)

Selection table for probe tube types and probes

Temperature

2)

1)

p. 20

1)

p. 20

1)

p. 20

1)

p. 20

p. 20

1)

p. 21

1) Back purging required


2) With regulated heating sleeve (see page 6)
3) See SCK Sampling system for dry gas sampling data sheet (publication no. 10/23-8.81 EN)

Lead-through tube installation


Brickwork with metal sheeting

5 3

Isolated sheet-metal channel

Brickwork

5 3

5 3

Flow direction of
process gas

1 Lead-through tube
2 Mounting flange DN 65, PN 6,
form B to DIN 2573
3 Gasket
4 Welded-on rectangular block
5 Sampling probe flange

Minimum distance xmin of the mounting flange


from the wall depending on mounting angle :

xmin / mm

10
133

15
138

20
143

25
147

30
151

35
153

Dimensions in mm
10/23-5.10 EN Rev. 10

System components for sample gas sampling

19

Type 40, Type 40 W Probe tubes

Use

Dimensional drawing (dimensions in mm)

For sampling hot dust-containing gases in conjunction with the


FE2 / PFE2 filter unit (see page 3 or page 7)

Max. temperature:
450 C
180 C
900 C
300 C
1300 C

Max. 300 l/h

Pressure drop

Approx. 10 hPa at 30 to 90 l/h

17,2

16

Special Steel Material No. 1.4893 (max. 900 C)

G3/4

L1

Dust content
Max. 3 g/m3 (application recommendation);
max. 40 g/m3 with purge-back device in conjunction with
FE2 / PFE2 filter unit (not for coated probe tube)

16

Silicon-Carbide (max. 1300 C)

15

SiC

Installation
G 3/4 in. external thread

Protective Tube
34

Flow rate

L1

23

Temperature
Probe tube version:
SS 1.4571 (SAE 316Ti)
SS 1.4571 (SAE 316Ti) coated
SS 1.4893
SS 1.4571 (SAE 316Ti) Type 40 W
Silicon carbide (max. length 1000 mm)

G3/4

21,4

pabs = 50 to 500 kPa (0.5 to 5 bar)

16,8

Pressure

12,6

Process gas sampling conditions

Special Steel Material No. 1.4571 (max. 450 C)

G3/4

105

L1

16

Mounting angle
Any; 8 to 90 downwards from the horizontal is recommended. It is imperative to install the silicon carbide probe
tube vertically.

Ordering information
Catalog No. 23036-0
Version
Stainless steel (1.4571), up to 500 C
Stainless steel (1.4571), coated, up to 180 C
Silicon carbide up to 1300 C, max. 1000 mm
Stainless steel (1.4893), up to 900C
Stainless steel (1.4571), up to 300 C, heated (Type 40 W for cement)

1
2
4
5
6

Nominal length
500 mm
1000 mm
1500 mm
2000 mm
2500 mm
3500 mm (only for heated version)
4000 mm (only for heated version)
4500 mm (only for heated version)

1
2
3
4
5
6
7
8

Catalog No. 23036-0-

20

System components for sample gas sampling

10/23-5.10 EN Rev. 10

Type 42 Probe tube (heated)


Use

Probe tube heater

Low gas temperature


High moisture content in gas
Corrosive components in the process gas

Heat output
Nominal length 1000 mm: 2 x 200 W
Nominal length 1500 mm: 2 x 300 W
Nominal length 2000 mm: 2 x 400 W

Typical places of use are:


Sampling points in wet desulphurization plants
(crude gas, clean gas, part-cleaned clean gas)
Waste incineration plants
Auxiliary boilers and stack emission measurements

Nominal voltage
120 V AC or 230 V AC, 50 to 60 Hz
Control
Control temperature max. 200 C
Temperature sensor
Pt 100

Process gas sampling conditions


Pressure
pabs = 200 kPa (2 bar)

Ordering information

Temperature
< 200 C

Catalog No.
23041-4-8018392
23041-4-8018393
23041-4-8018394

Length 1000 mm
Length 1500 mm
Length 2000 mm

Flow rate
Max. 250 l/h
Flow velocity
Max. 12 m/s (> 1000 mm max. 7 m/s)
Dust content
Max. 3 g/m3 (application recommendation);
max. 40 g/m3 with purge-back device in conjunction with
FE2 / PFE2 filter unit (see page 3 or page 7)
T90 time
Approx. 0.4 s at 250 l/h

Dimensional drawing (dimensions in mm) and terminal diagram


40
17

160

21

1000/1500/2000 mm

Heater

120

40 x 2

25 x 1,5

13

Pt100
123456 789

Bridge:
Line 230 V Terminals 3+4
Line 115 V Terminals 2+3/4+5

Length

M20

Wattage

(W)

400

600

800

Weight

(kg)

10

12

(mm) 1000 1500 2000

Line Sensor

90

Temperature Controller
Connection

10/23-5.10 EN Rev. 10

System components for sample gas sampling

21

Type 60 Probe tube (cement flue gas probe)


Use

Cooling water supply

For sampling hot cement flue gas with high dust content for
CO, CO2, NO and SO2 analysis in dry cement production
process (e.g. recuperator furnaces, furnaces with grate
coolers), at rotary kiln inlet and/or after precalcination.

Quality
Drinking water quality with approx. 30 % anti-freeze if
required
Outlet temperature
Min. 50 C (or > dew point of the cement flue gas),
max. 85 C

Process gas sampling conditions

Pressure
pabs = max. 400 kPa (4 bar)

Pressure
pabs = max. 200 kPa (2 bar)
Temperature
Probe tube length:
3500 mm
3000 mm
2500 mm
2000 mm
1500 mm

Quantity circulated
Approx. 3 m3/h (closed system)

Max. temperature:
1200 C
1250 C
1300 C
1350 C
1400 C

Type 60 S Probe tube


Model with reinforced protection tube and flange DN 150, PN 16

Flow rate
Max. 250 l/h

Ordering information

Dust content
Max. 2000 g/m3 with periodical compressed air cleaning in
conjunction with FE2 filter unit (see page 3)

Length 1500 mm
Length 2000 mm
Length 2500 mm
Length 3000 mm
Length 3500 mm
Length 1500 mm, reinforced protection tube
Length 2000 mm, reinforced protection tube
Length 2500 mm, reinforced protection tube
Length 3000 mm, reinforced protection tube
Length 3500 mm, reinforced protection tube
Type 60 S, length 1500 mm
Type 60 S, length 2000 mm
Type 60 S, length 2500 mm
Type 60 S, length 3000 mm
Type 60 S, length 3500 mm
Type H, length 1500 mm
Type H, length 2000 mm
Type H, length 2500 mm
Type H, length 3000 mm
Type H, length 3500 mm

Dead time (Tt) for length = 3500 mm


Approx. 40 s at 60 l/h, approx. 9 s at 250 l/h
90% time (T90) for length = 3500 mm
Approx. 82 s at 60 l/h, approx. 17 s at 250 l/h
Pressure drop
Approx. 10 hPa

Materials of gas-conducting parts


Special steel 1.4541 (SAE 321)

Mounting
A flanged probe connector (internal diameter 200 mm) should
be installed by the customer. The mounting flange is essential
for installing the probe tube. The connections should be
aligned according to the local situation.

Catalog No.
23038-4-0856831
23038-4-0856832
23038-4-0856833
23038-4-0856834
23038-4-0856835
23038-4-8018478
23038-4-8018479
23038-4-8018480
23038-4-8018481
23038-4-8018482
23038-4-0730642
23038-4-0730643
23038-4-0730644
23038-4-0730645
23038-4-0730646
23020-4-0730656
23020-4-0730647
23020-4-0730648
23020-4-0730649
23020-4-0730650

Dimensional drawing (dimensions in mm)


~60

60,3

~70

35

89

90
L2

L3

L1

22

System components for sample gas sampling

1 Sample gas inlet


ports
2 Thickened shank
of probe tube
3 Cooling water
connections
L1 Probe tube length
L2 Length of
thickened shank:
800 mm for
L1 2000 mm
1300 mm for
L1 2500 mm
L3 200 mm with
reinforced
protection tube

10/23-5.10 EN Rev. 10

Probe 2

Use

Probe tube heating

Wherever large volumes of gas are sampled, gas pressure is


raised and there is a high moisture or dust content in the gas.

Heat output (unregulated)


Nominal length 1200 mm: 650 W,
partially heated (for heating of the wall bushing): 255 W

Process gas sampling conditions

Nominal voltage
230 V AC, 50 to 60 Hz (120 V AC on inquiry)

Pressure
pabs = max. 400 kPa (4 bar)

Electrical connection
Silicone cable, 3 x 1.5 mm2, length 1000 mm

Temperature
Max. 450 C (probe tube partly heated),
max. 130 C (probe tube heated

Protective case (option)

Flow rate
Max. 2000 l/h

Dimensions
270 x 203 x 330 mm (H x W x D)

Dust content
Max. 20 g/m3 (application recommendation),
max. 100 g/m3 with purging

Material
Special steel 1.4301 (SAE 304)

Purging pressure
Max. 600 kPa (6 bar)
Heating temperature of inlet filter
200 C (at process gas temperature of 20 C)
90% time (T90)
< 2 s at 250 l/h

Degree of protection of case


IP54
Weight
Approx. 7 kg
Ambient temperature
20 to +45 C

Dimensional drawing (dimensions in mm)

Filter fineness
0.3 m

Material of gas-conducting parts


Support tube, heating rod, connecting pipe
Special steel 1.4571 (SAE 316Ti)
Inlet filter
Aluminum oxide

Seals
Ceramic fiber

650

Flange
Special steel 1.4581
1
2
3
4
5

Mounting
Flange
DN 65, PN 6, form B, to DIN 2573
position of holes: 45, 135, 225, 315
Mounting angle
Any; 10 to 35 downwards from the horizontal recommended (take direction of flow into account), see dim. drawing
Sample gas outlet
G 1/4 in. internal thread
Test gas / purge air inlet
G 3/8 in. internal thread
10/23-5.10 EN Rev. 10

180

Mounting for the inlet filter


Inlet filter (inner filter) with internal heating rod
Gas sampling tube
Wall tube with inlet flange
Sample gas outlet or test gas / purge air inlet

Ordering information
Catalog No.
1200 mm, 230 V, 50/60 Hz, 650 W
23022-4-0768301
1200 mm, 230 V, 50/60 Hz, 255 W, part. heat.23022-4-0768305
Prot. box, insulat., IP54, (330x203x270 mm) 23022-4-0730719

System components for sample gas sampling

23

Probe 11
Use

Dimensional drawing (dimensions in mm)

Use in interior air, garage and tunnel monitoring, including


corrosive atmospheres. The materials used ensure that with the
gases normally occurring no adsorption occurs.

Technical data
Sampling pressure
Atmospheric pressure
Gas temperature
25 to +50 C, dry
Sample gas flow rate
Max. 70 l/h
Dust content
Max. 1 mg/m3
Pressure drop with new filter
10 hPa (mbar) at 70 l/h
Service life of filter (estimated)
filter constant (2500)
d (days) =
flow rate (l/h) x dust concentration (mg/m3)

Ordering information

Sample gas connection port


Bolted connection for flexible pipe with internal diameter
4 mm and external diameter 7 mm

Room air probe 11

Catalog No.
23021-4-0859585

Materials
Polycarbonate (probe head), aluminum oxide (filter)
Transport and storage temperature
25 to +70 C
Mounting
On wall or suspended from ceiling

24

System components for sample gas sampling

10/23-5.10 EN Rev. 10

Ceramic filter
Use
For filtering dust from gases in the gas conditioning systems of
analyzer systems when the gas sampling probe does not have
a filter. The ceramic filter is positioned upstream the other
devices in the sample gas conditioning chain. The ceramic filter
can be heated with the annular heating element if condensation
from the sample gas is likely.

Technical data
Flow rate (air)
Max. 300 l/h
Gas pressure
pabs = 20 kPa to 1.7 MPa (0.2 to 17 bar) at 20 C filter
temperature, max. 200 kPa (2 bar) at 180 C
Pressure drop
0.1 to 0.85 hPa at 30 to 250 l/h (air)
Dynamic characteristics at
Flow rate (air)
30 l/h
3.7 s
Dead time Tt
11.5 s
90% time T90

60 l/h
2.3 s
5.5 s

90 l/h
1.7 s
3.9 s

Filter fineness
0.3 m

Dimensional drawing (dimensions in mm)

Construction, mounting
Materials of gas-conducting parts
Housing: steel, St 37 K or special steel 1.4571 (SAE 316Ti);
filter: aluminum oxide; seals: FPM, Cu, Al2O3 fiber

incl. T-handle (not shown)

Gas connection ports


G 1/4 in. internal thread or
pipe connectors for pipe of internal diameter 4 mm
Filter surface
Approx. 212 cm2
Weight
Approx. 2.1 kg
Filter heating
Annular heating element, see page 5
Mounting
On wall with angle bracket

Ordering information
Ceramic filter, steel version
Ceramic filter, stainless steel version

10/23-5.10 EN Rev. 10

System components for sample gas sampling

Catalog No.
23031-5-8018177
23031-5-8018178

25

Process pressure reducers


Use
If the pressure of the process gas is too high for the analyzer, a
pressure reducer is required to lower the pressure. The type of
pressure reducer used is determined by the properties of the
process gas and the required sample gas pressure.

Technical data
Casing: brass

Casing: brass

Casing: special steel

Casing: special steel

Single-stage with one


manometer (outlet)
Max. 1.5 MPa (15 bar)
0.8 to 10 kPa
(8 to 100 mbar)

Single-stage without
manometer
Max. 3.5 MPa (35 bar)
10 to 70 kPa
(0.1 to 0.7 bar)
80 kPa
(0.8 bar)

25 to 250 l/h
Special steel
EPDM
Special steel

Single-stage with two


manometers (inlet /outlet)
Max. 3.5 MPa (35 bar)
10 to 70 kPa
(0.1 to 0.7 bar)
80 kPa
(0.8 bar)
0 to 4 MPa
(0 to 40 bar)
100 to +150 kPa
(1 to +1.5 bar)
25 to 250 l/h
Special steel
EPDM
Special steel

Approx. 2.35 kg
Max. 50 C

Approx. 2.35 kg
Max. 50 C

23422-4-0730699

23422-4-0730700

Weight
Gas temperature and
ambient temperature

Approx. 1.25 kg
Max. 50 C

Single-stage with two


manometers (inlet /outlet)
Max. 3.5 MPa (35 bar)
10 to 40 kPa
(0.1 to 0.4 bar)
50 kPa
(0.5 bar)
0 to 4 MPa
(0 to 40 bar)
0 to 60 kPa
(0 to 0.6 bar)
25 to 250 l/h
Buna rubber
Buna rubber
Special steel; gasconducting parts: brass
Approx. 2.65 kg
Max. 50 C

Catalog No.

23035-5-5864958

23035-5-5864951

Construction
Inlet pressure
Outlet pressure
(adjustable)
Safety valve set to

Manometer display
inlet pressure
Manometer display
outlet pressure
Flow rate
Material diaphragm
Material gasket
Material housing

0 to 250 hPa
(0 to 250 mbar)
25 to 250 l/h
Buna rubber
Buna rubber
Brass

Supplied: Pressure reducer with angle bracket

26

System components for sample gas sampling

10/23-5.10 EN Rev. 10

Process pressure reducers


Dimensional drawings (dimensions in mm)
Pressure reducer single-stage with one manometer (outlet)
(Catalog No. 23035-5-5864958)

Pressure reducer single-stage without manometer


(Catalog No. 23422-4-0730699)

appro

79

NPTF

ble)
(varia

NPTF

x. 30

105

GasTech

approx. 94
(depending on handwheel position)

Pressure reducer single-stage with two manometers


(inlet /outlet) (Catalog No. 23035-5-5864951)

Pressure reducer single-stage with two manometers


(inlet /outlet) (Catalog No. 23422-4-0730700)

118

NPTF
appro

148

NPTF

ble)
(varia

NPTF

x. 30

GasTech

approx. 94
(depending on handwheel position)

10/23-5.10 EN Rev. 10

System components for sample gas sampling

27

Heated sample gas lines


CGWB 13 Heated sample gas line

Parallel strip heater (holding temperature max. 200 C)


Pt 100 resistance thermometer for regulation
Self-regulating anti-frost heater (max. 30 C)
Self-regulating heater (option, holding temp. max. 100 C)
TBL 01-S Heated sample gas line

Fixed resistor heat. conductor (holding temp. max. 200 C)


Pt 100 resistance thermometer for regulation
Self-regulating heater (option, holding temp. max. 100 C)
TBL 01-C Heated sample gas line

Self-regulating heater (holding temp. max. 100/120 C)


Integral pipe-end connectors for cement analysis systems
TBL 01-E Heated sample gas line

Competitive version
Pipe ends with polyamide hard caps

Selection table for heated sample gas lines


Heater
Self-regulating strip heater (30 C)
Self-regulating strip heater (100 C)
Self-regulating strip heater (120 C)
Fixed resistor heat. cond. (200 C)
Parallel strip heater (200 C)
Outer covering
Options
Line can be shortened
Small bending radius
Gas connections
Electrical connections
Maximum line length
Applications
CO, O2, CO2
CO, O2, CO2
SO2, NOx, CnHm
Cement analysis systems
Technical data

CGWB 13

TBL 01-S

TBL 01-C

TBL 01-E

x
x

x
Polyvinyl chloride (PVC)

Polyamide (PA)

x
x

Metal or PVC

Polyamide (PA)

Various options
Heater and Pt 100 fixed
130 m

x 1) / 2)
x
Various options
Heater and Pt 100 fixed
100 m

x
x
Various options
Heater and Pt 100 fixed
70 m

x
PTFE
Heater and Pt 100 fixed
40 m

Holding temp. 120 C


see page 33

Holding temp. 200 C

see page 33

Anti-frost heater

Holding temp. 100 C Holding temp. 100 C


Holding temp. 200 C Holding temp. 200 C

see page 30
see page 33

1) Version with self-regulating strip heater


2) Version with fixed resistor heating conductor

28

System components for sample gas sampling

10/23-5.10 EN Rev. 10

Heated sample gas lines


Integral pipe-end connectors
Flange

Silicone cap

Metal cap

POM cap and shrunk-on hose

Hard cap

10/23-5.10 EN Rev. 10

System components for sample gas sampling

29

CGWB 13 Heated sample gas line


Technical data
Frost protected line
Outer covering
Medium-carrying pipe
Integral pipe-end connectors

PVC
PTFE
Various options (see ordering
information, page 32)
Heater
self-regulating strip heater
Power supply
230 V or 120 V, 50 to 60 Hz
Heat output
16 W/m
Making / holding current
Current consumption
= 65 / 25 mA
Holding temperature
see diagram
Ambient temperature
30 to +60 C
Outer diameter
30 mm
Flexible sample gas pipe
6 x 4 x 1 mm or 8 x 6 x 1 mm
Maximum line length
130 m
Line duct
M42
Minimum bending radius
300 mm
Weight
Approx. 1 kg/m
Connect. lead for heater (fixed) 3 x 2.5 mm2; length 5 m
Connect. lead for Pt 100 (fixed)

Self-regulating strip heater

Regulated parallel strip heater

PVC
PTFE
Various options (see ordering
information, page 32)
self-regulating strip heater
230 V or 120 V, 50 to 60 Hz
30 W/m
0.15 A/m

PVC
PTFE
Various options (see ordering
information, page 32)
CPD heating element, regulated
230 V or 120 V, 50 to 60 Hz
60 W/m
0.3 A/m

see diagram
30 to +60 C
43 mm
6 x 4 x 1 mm or 8 x 6 x 1 mm
90 m
M42
300 mm
Approx. 1 kg/m
3 x 2.5 mm2; length 5 m

200 C
30 to +60 C
40 mm
6 x 4 x 1 mm or 8 x 6 x 1 mm
60 m
M42
300 mm
Approx. 1 kg/m
3 x 2.5 mm2; length 5 m
LIYCI 2 x 0.14 mm2; length 5 m

Holding temperature diagrams

Medium pipe temperature C

Frost protected line, 6 x 4 x 1 mm PTFE, 16 W/m, self-regulating


50
40
30
20

- 30

- 20

- 10

+ 10

+ 20

+ 30

+ 40

Ambient temperature C

Medium pipe temperature C

Self-regulating strip heater, 6 x 4 x 1 mm PTFE, 30 W/m


100
90
80
70

- 30

- 20

- 10

+ 10

+ 20

+ 30

+ 40

Ambient temperature C

30

System components for sample gas sampling

10/23-5.10 EN Rev. 10

System components for sample gas sampling

54

46

63

Replacable tube nipple,


316ss, 6x1 or 8x1 mm

300

25

Sample take-off side

Sample take-off side

Length by customers request


max. length depending on MCB or
switching load of the controller respectively

Length by customers request


max. length depending on MCB

POM cap

Shrinking hose

POM cap

Shrinking hose

Pt100
Cable 2 x 0.14 mm

Power Supply
Cable 3 x 1.5...2.5 mm

300

Analyzer side

Power Supply
Cable 3 x 1.5...2.5 mm

300

Analyzer side

CGWB 13 Self-regulating strip heater

49

42

42

10/23-5.10 EN Rev. 10
46

46

Process tube overhang,


SS-nipple 6x1 or 8x1 mm

CGWB 13 Heated sample gas line

Dimensional drawings (dimensions in mm)


CGWB 13 Regulated parallel strip heater

31

CGWB 13 Heated sample gas line


Ordering information
Catalog No. 23281-0
Version
Parallel strip heater 60 W/m, line can be shortened, regulated (Pt 100), 200 C
Self-regulating 16 W/m, 30 C (antifreeze)
Self-regulating 30 W/m, 100 C

2
3
7

Integral pipe-end connectors


Probe: metal cap for PFE2/3 analysis: plastic cap with shrunk-on hose
Probe: metal cap for PFE2/3 analysis: flange
Both sides with POM plastic cap (for self-regulated versions only)
Probe: PTFE cap for PFE2/3 in conf. set analysis: POM plastic cap
Probe: metal cap for PFE2/3 in conf. set analysis: plastic cap with shrunk-on hose

2
3
4
5
6

Gas conducting line


PTFE tube 6x4x1 mm
PTFE tube 8x6x1 mm

1
2

Power supply
230 V, 50 to 60 Hz
120 V, 50 to 60 Hz

1
2

Controlling and monitoring


without Pt 100 (for self-regulated versions only)
with 1 x Pt 100 (fixed built-in)

0
1

Catalog No. 23281-0-

32

System components for sample gas sampling

10/23-5.10 EN Rev. 10

TBL 01-S, TBL 01-C, TBL 01-E Heated sample gas lines
Technical data
TBL 01-S Self-regulating strip heater
Outer covering
Medium-carrying pipe
Test gas pipe (unheated, option)
Integral pipe end connectors

Power supply
Heat output
Holding temperature
Ambient temperature
Outer diameter
Maximum line length
Line duct
Minimum bending radius
Weight
Electrical connection for
heater and Pt 100 (fixed)

Outer covering
Medium-carrying pipe
Integral pipe end connectors

Power supply
Heat output
Holding temperature
Ambient temperature
Outer diameter
Maximum line length
Line duct
Minimum bending radius
Weight
Electrical connection for
heater and Pt 100 (fixed)

10/23-5.10 EN Rev. 10

TBL 01-S Fixed resistor heating conductor

Polyamide corrugated tubing


Polyamide corrugated tubing
PTFE pipe 6 x 4 x 1 mm or 8 x 6 x 1 mm
PTFE pipe 6 x 4 x 1 mm or 8 x 6 x 1 mm
PTFE pipe 6 x 4 x 1 mm (500 mm protruding)
PTFE pipe 6 x 4 x 1 mm (500 mm protruding)
Probe: metal cap, analyzer: flange or hard caps on both sides (pipe protruding 300 mm) or
silicone caps on both sides (probe: 6/4 stainless steel connections, analyzer: pipe protruding
300 mm) or PTFE caps with 6/4 stainless steel connections on both sides, test gas pipe
protruding 500 mm on both sides
230 V or 120 V, 50 to 60 Hz
230 V or 120 V, 50 to 60 Hz
38 W/m
90 W/m
see diagram on page 30
200 C
30 to +60 C
30 to +60 C
43 mm
43 mm
100 m
40 m
M48
M48
200 mm
200 mm
Approx. 1 kg/m
Approx. 1 kg/m
3 x 2.5 mm2, length 5 m
3 x 2.5 mm2 or 2 x 0.14 mm2, length 5 m

TBL 01-C Self-regulating strip heater

TBL 01-E Fixed resistor heating conductor

Metal corrugated tubing (for ACK) or


PVC outer covering (for ACMP, ACX)
PTFE pipe 6 x 4 x 1 mm
Probe: metal cap analyzer: silicone cap
(mandatory for ACK) or POM plastic caps on
both sides (mandatory for ACMP, ACX) or
probe: PTFE cap analyzer: POM plastic cap
(mandatory for ACMP, ACX 120C)
230 V or 120 V, 50 to 60 Hz
30 W/m or 47 W/m
100 C or 120 C
30 to +60 C
43 mm
70 m
M48
200 mm
Approx. 1 kg/m
3 x 2.5 mm2 or 2 x 0.14 mm2, length 5 m

Polyamide corrugated tubing


PTFE pipe 6 x 4 x 1 mm or 8 x 6 x 1 mm
Polyamide hard caps

230 V or 120 V, 50 to 60 Hz
90 W/m
200 C
30 to +60 C
43 mm
40 m
M48
200 mm
Approx. 1 kg/m
3 x 2.5 mm2 or 2 x 0.14 mm2, length 5 m

System components for sample gas sampling

33

50

System components for sample gas sampling

50

56

42

6 mm

300

Replacable tube nipple,


316ss, 6x1 or 8x1 mm

60

25

Power supply
Cable 3 x 1.5...2.5 mm

81

PA corrugated hose

Analyzer side

Power supply
Cable 3 x 1.5...2.5 mm

Hard cap

PA corrugated hose

Length by customers request


max. length depending on MCB or
switching load of the controller respectively

Pt100
Cable 2 x 0.14 mm

Length by customers request


max. length depending on MCB

350

Hard cap

81

24

25

Sample take-off side

300

Process tube overhang

54

350
42

42

Sample take-off side

63

34

49

TBL 01-S, pipe end connectors with hard caps

49

Analyzer side

TBL 01-S, TBL 01-C, TBL 01-E Heated sample gas lines

Dimensional drawings (dimensions in mm)


TBL 01-S, pipe end connectors with flange and metal cap

10/23-5.10 EN Rev. 10

10/23-5.10 EN Rev. 10

System components for sample gas sampling

50

300

Process tube overhang

Hard cap

2 x M16
Cable Gland

Power supply
Cable 3 x 1.5...2.5 mm

Length by customers request


max. length depending on MCB or
switching load of the controller respectively

PA corrugated hose

Pt100
Cable 2 x 0.14 mm

Power cupply
Cable 3 x 1.5...2.5 mm

Length by customers request


max. length depending on MCB or
switching load of the controller respectively

42
Hard cap

350

81

54

49
6

300

56

42

6 mm

Process tube overhang

Sample take-off side

24

25

Sample take-off side

TBL 01-S, pipe end connectors with metal caps for ACF

Analyzer side

Replaceable tube nipple,


316ss, 8x1 mm

PA corrugated hose

Pt100
Cable 2 x 0.14 mm

63
50
60

Analyzer side

TBL 01-S, TBL 01-C, TBL 01-E Heated sample gas lines

Dimensional drawings (dimensions in mm)


TBL 01-E

35

42

54

300

Process tube overhang

Replacable tube nipple,


316ss, 6x1 mm

63

49

25

Sample take-off side

81

45

Length by customers request


max. length depending on MCB

PVC Jacket

Length by customers request


max. length depending on MCB or
switching load of the controller respectively

System components for sample gas sampling

300

Pt100
Cable 2 x 0.14 mm

Power Supply
Cable 3 x 1.5...2.5 mm

300

Analyzer side

Pt100
Cable 2 x 0,14 mm

Power supply
Cable 3 x 1,5...2,5 mm

POM cap

Shrinking hose

Silicone cap

Process tube overhang

Analyzer side

TBL 01-C, pipe end connectors for ACK

46

Metall
corrugated hose

51

36
46

Sample take-off side

TBL 01-S, TBL 01-C, TBL 01-E Heated sample gas lines

Dimensional drawings (dimensions in mm)


TBL 01-C, pipe end connectors for ACMP and ACX

10/23-5.10 EN Rev. 10

42

TBL 01-S, TBL 01-C, TBL 01-E Heated sample gas lines
TBL 01-S Ordering information
Catalog No. 23283-0
Version
Fixed resistor heating strip, 90 W/m, holding temperature 200 C (for ACX)
Self-regulated heating strip, 38 W/m, holding temperature 100 C
Fixed resistor heating strip 90 W/m, holding temperature 200 C (for ACF)
Self-regulated heating strip, 38 W/m, holding temperature 100 C (for SCK)

1
2
4
6

Gas conducting line


with PTFE tube 6x4x1 mm
with PTFE tube 8x6x1 mm (ACF)
with PTFE-tube 6x4x1 mm incl. an additional unheated PTFE tube for test gas
6x4x1 mm (500 mm protruding)
with PTFE-tube 8x6x1 mm incl. an additional unheated PTFE tube for test gas
6x4x1 mm (500 mm protruding, ACF)

1
3
4
5

Material of sheathing
with plastic hose of PA (outside and indoors installation)

Connections
Metal caps w. 6/4 SS connectors on both sides (ACF)
Probe: metal cap analyzer: flange, 6/4 SS connectors on both sides
Plastic hard caps on both sides (tube 300 mm protruding, self-regulated only)
Silicone caps both sidesprobe 6/4 SS conn.analyzer: tube 300 mm protruding (SCK)
PTFE caps with 6/4 SS connectors on both sides (ACF)
PTFE caps with 6/4 SS connectors on both sides for sample gas and PTFE tube for
test gas 500 mm protruding on both sides (ACF)

A
B
C
D
E
F

Controlling and monitoring


without Pt 100 (self-regulated version only)
with 1 x Pt 100
with 2 x Pt 100

0
1
2

Power supply
230 V, 50 to 60 Hz, for self-regulated heating strip (for SCK, not for ACF)
120 V, 50 to 60 Hz, for self-regulated heating strip (for SCK, not for ACF)
230 V, 50 to 60 Hz, for fixed resistor heating conductor 90 W/m
120 V, 50 to 60 Hz, for fixed resistor heating conductor 90 W/m
230 V, 50 to 60 Hz, for fixed resistor heating cond. 90 W/m (ACX, ACF, 35 m)
120 V, 50 to 60 Hz, for fixed resistor heating cond. 90 W/m (ACX, ACF, 15 m)
400 V / 230 V, 50 to 60 Hz, for fixed res. heat. cond. 90 W/m (ACX, ACF, 3560 m)
208 V / 120 V, 50 to 60 Hz, for fixed res. heat. cond. 90 W/m (ACX, ACF, 1540 m)
120 V, 50 to 60 Hz, self-regulated heating strip (for SCK with AWG wiring)

1
2
3
4
5
6
7
8
9

Catalog No. 23283-0-

10/23-5.10 EN Rev. 10

System components for sample gas sampling

37

TBL 01-S, TBL 01-C, TBL 01-E Heated sample gas lines
Additional ordering information TBL 01-S
Fixed resistor heating strip 90 W/m, 6x4x1 mm, length m
Fixed resistor heating strip 90 W/m, 8x6x1 mm, length m
Self-regulated heating strip 38 W/m, 6x4x1 mm, length m
Self-regulated heating strip 38 W/m, 6x4x1 mm, length m
Self-regulated heating strip 38 W/m, 8x6x1 mm, length m
Fixed res. heat. strip, PTFE tube 6x4x1 mm incl. add. unheated PFTE tube for test g. 6x4x1 mm (500 mm protruding), l. m
Fixed res. heat. strip, PTFE tube 8x6x1 mm incl. add. unheated PFTE tube for test g. 6x4x1 mm (500 mm protruding), l. m
Fixed res. heat. strip 90W/m, 400V/230V, 5060 Hz, (ACF, line length 3560m) with PTFE tube 8x6x1 mm, length m
Fixed res. heat. strip 90W/m, 208V/120V, 5060 Hz, (ACF, line length 1540m) with PTFE tube 8x6x1 mm, length m

BA No.
301
303
304
307
309
311
313
315
317

TBL 01-C Ordering information


Catalog No. 23285-0
Design
Self-regulating strip heater, 30 W/m, 100 C (ACK)
Self-regulating strip heater, 30 W/m, 100 C (ACMP, ACX coal bin)
Self-regulating strip heater, 47 W/m, 120 C (ACMP, ACX pre-heater)

2
3
4

Gas conducting line


with PTFE tube 6x4x1 mm

Material of sheathing
with metal corrugated tubing for ACK (outdoor and indoor installation)
with PVC sheathing for ACMP, ACX (outdoor and indoor installation)

1
2

Connections
Probe: metal cap, analyzer: silicone cap (mandatory for ACK) + shortening kit
POM plastic caps on both sides (mandatory for ACMP, ACX) + shortening kit
Probe: PTFE caps, analyzer: POM caps (mand. for ACMP, ACX 120C) + shorten. kit

1
2
3

Control / monitoring
with 1 x Pt 100

Power supply
230 V, 50 to 60 Hz
120 V, 50 to 60 Hz

1
2

Catalog No. 23285-0-

TBL 01-E Ordering information


Fixed resistor heating conductor 90 W/m, PTFE 6x4x1, PA caps, 230 V
Fixed resistor heating conductor 90 W/m, PTFE 8x6x1, PA caps, 230 V
Fixed resistor heating conductor 90 W/m, PTFE 6x4x1, PA caps, 120 V
Fixed resistor heating conductor 90 W/m, PTFE 8x6x1, PA caps, 120 V

38

Catalog No.
23284-4-0730695
23284-4-0730696
23284-4-0730697
23284-4-0730698

System components for sample gas sampling

10/23-5.10 EN Rev. 10

Electronic temperature controller and switching relay

Outputs
2 x relay 3 A, 250 V AC
Power supply
110 to 240 V AC +10/15 %, 48 to 63 Hz

L1

Dimensions
48 x 48 mm, C-rail housing

not used

110...240 VAC
-15/+10%
48...63 Hz

Measurement input
Pt 100

342 343 341 142 143

Alarm 1
Temperature

max.
230V
/3A

0/12V
+

Weight
140 g

Binary
Output 1

Connection diagram

Control range
200 to +850 C

81

83

GND

Temperature controller

max.
230V
/3A

Alarm 2
Limiter

Switching relay

242 243

Max. load current


Irms = 30 A (ambient temperature = 25 C)
Weight
200 g

4+

Catalog No.

10/23-5.10 EN Rev. 10

3-

M2A

Ordering information
Temperature controller
parameters not set
parameters set for filter unit
parameters set for sample gas line
parameters set for self-regulating
heater for ACMP, ACX
Switching relay

80 112 111 113

Logic
Outputs

Binary
Output 2

Load voltage
Urms = 24 to 265 V

23345-5-8328907
23345-5-8328907P
23345-5-8328907L
23345-5-8328907C

1
L

Last
For load current > 2 A
use coupling relay

23345-5-8328731

System components for sample gas sampling

39

ABB Limited
Process Automation
Oldends Lane
GL10 3TA Stonehouse
Gloucestershire, United Kingdom
Phone: +44 1 453 826661
Fax:
+44 1 453 829671

ABB Australia Pty Limited


Process Automation
Bapaume Road
2170 Moorebank
New South Wales, Australia
Phone: +61 2 9821 0968
Fax:
+61 2 9400 7050

ABB Pte. Ltd.


Process Automation
2 Ayer Rajah Crescent
139935 Singapore, Singapore
Phone: +65 6773 5961
Fax:
+65 6778 0222

ABB Ltd.
Process Automation
14 Mathura Road
121003 Faridabad, Haryana, India
Phone: +91 129 2279627
Fax:
+91 129 2279692

ABB Engineering Ltd.


Process Automation
10 Jiuxianqiao Lu
100015 Beijing, China
Phone: +86 10 84566688 Ext. 6217
Fax:
+86 10 84567650

ABB Automation GmbH


Process Automation
Stierstaedter Strasse 5
60488 Frankfurt am Main, Germany
Fax:
+49 69 79304566
Email: cga@de.abb.com

ABB Inc.
Process Automation
3700 W Sam Houston Parkway South,
Suite 600, Houston, TX 77042, USA
Phone: +1 713 587 8000
www.abb.com/analytical

Note
We reserve the right to make technical changes or
modify the contents of this document without prior
notice. With regard to purchase orders, the agreed
particulars shall prevail. ABB does not accept any
responsibility whatsoever for potential errors or
possible lack of information in this document.
We reserve all rights in this document and in the
subject matter and illustrations contained therein.
Any reproduction, disclosure to third parties or
utilization of its contents in whole or in parts is
forbidden without prior written consent of ABB.
Copyright 2013 ABB
All rights reserved

Sales

Service

10/235.10 EN Rev. 10 08.2013

Contact us

You might also like