Combined Interrogator and Transmitter

Datasheet Module T02-1400

ES0195A00035

Module T02-1400

Document No.: ES0195A00035


Revision: 00
Revision Date: 2010-01-02
1

Datasheet Module T02-1400

Copyright 2009 by ERA a.s. Pardubice

All rights reserved. This document and the information it contains are property of ERA a.s. and
confidential. They shall not be reproduced nor disclosed to any person except to those having a need
to know them, without prior written consent of ERA a.s.

L500: ES0195A00035-00

ERA a.s.
Prmyslov 387
530 03 Pardubice
Czech Republic
Tel: + 420 467 004 253
Fax: +420 466 670 461
www.erabeyondradar.com

Module T02-1400

Datasheet

Table of Contents
1

PURPOSE..............................................................................................5

BLOCK DIAGRAM.................................................................................5

BRIEF TECHNICAL DESCRIPTION......................................................6

LIST OF ESSENTIAL PARAMETERS...................................................7

SUBJECT ILLUSTRATION WITH PARTICULAR PARTS


LABELING .............................................................................................9

LIST OF CONNECTION POINTS ........................................................11

LIST OF INDICATORS ........................................................................11

INDICATION AND LOCALIZATION OF ERROR CONDITIONS .........12

LIST OF SETUP AND CONTROL ELEMENTS ...................................12

10

LIST OF DIAGNOSTIC OUTPUTS ......................................................12

11

REPLACEMENT PROCEDURE ..........................................................13

11.1
11.2
11.3
11.4

DISASSEMBLY .............................................................................................................13
ASSEMBLY ..................................................................................................................13
T02-1400 MODULE IP ADDRESSES AND NTP SERVER ADDRESSES SETTING AFTER
REPLACEMENT ............................................................................................................14
PROCEDURE OF OUTPUT POWER DECREASE AND SWR MONITORING TURNING
OUT ON FREQUENCY OF 1090 MHZ .............................................................................18

Module T02-1400

Datasheet

Purpose
The T02-1400 module is a combined interrogator in A/C/S modes and check
responses transmitter in S mode for MLAT system integrity testing and time
synchronization of MLAT systems with distributed time and elliptical-hyperbolical
MLAT systems.

Block Diagram

Figure 2-1 T02-1400 Module Block diagram

Datasheet

Module T02-1400

Brief Technical Description


The modulator block diagram is shown in Figure 2-1. A high-accuracy, thermal
compensated quartz oscillator 10 MHz is a source of the clock signal. Its frequency
is multiplied 4 times for the digital part timing. A VCO is utilized for the actuating
signal generation of the HF part, which is phase-locked to this high-accuracy
oscillator. For the digital part clock signal generation, an external 10 MHz clock
signal may be optionally applied. The T02-1400 module control is ensured by a 32bit embedded software Microblaze processor, which is recorded to the FPGA Xilinx
of the Spartan 3 XC3S4000 series. The processor is extended by a SRAM external
memory, which the program part is executed from, and by a serial FLASH.
Communication with the CPS occurs via the 10/100 Mbit Ethernet TCP/IP protocol.
Commands and diagnostics are converted to the RS232 protocol in the XPORT
block for the Microblaze processor. The T02-1400 module is provided with two
pieces of XPORT, one of which is a Master, the other is a Slave. In addition,
communication with two independent CPS can be established simultaneously in
each of them. Consequently, altogether four independent CPS can command the
module T02-1400, and in case of the communication interruption with the CPS,
which currently commands, the command shall be automatically changed over to
the operating CPS with the highest priority.
The HF signal with required frequency (1030 MHz or 1090 MHz) created in the
synthesizer and VCO block is amplitude and phase modulated in the modulator
block. Obtained signal is then filtered in switched band pass filters, and after the
amplification in the low-pass filter for the spurious frequency components removal.
The signal is amplified in two parts it is amplified to 100 W in a three-stage boost
amplifier (RF Section 1) and then lead to the RF Section 2. It consists of a balanced
pair of 800 W amplifiers (2 x 400 W LDMOS transistor) operating in the linear AB
class, which amplifies the signal to demanded 1400 W. Constant pre-current of
these transistors in the operating temperature range is maintained by the
microprocessor of 8051 series with DA and AD converters and C8051F015
thermometer. This processor performs also diagnostics of the RF Section 2 (SWR),
and transfers the diagnostic information to the Digital Section 1 for further
processing.
Required transmission power is attained with the help of a digital attenuator and the
control of the RF Section 1 boost amplifier last two stages. On the RF Section 1 and
RF Section 2 outputs, circulators for the protection against returned power are
connected, and circuits monitoring output power and SWR as well. The HF output is
protected against overvoltage effects by means of a lightning arrester with a quarterwave short-circuited line. Power supply input is also protected against the
overvoltage effects. Thermometers are situated on the digital part card and under
the HF part card, temperature readings of which are used for possible decreasing or
turning out the transmission output power in case of the T02-1400 module
overheating. The T02-1400 module is equipped with a 75 driver with overvoltage
protection for possible connection to the measuring unit (envelope of transmitted
interrogations and responses).

Module T02-1400

Datasheet

List of Essential Parameters


Electrical parameters
Supply voltage

+20 +30 V (nominal +24 V) DC

Power consumption

max. 150 W

Frequency of carrier

1030 MHz
1090 MHz

Rated output power (at 25 C)

61.5 1 dBm for 1030 MHz


57 + 1 dBm/-2 dBm for 1090 MHz

Output power control

-10 dB min/1 dB step

Temperature stability of output


power

Pnom 1 dB

Maximum space factor

2%

Interrogation modes

A, C, S

Check response modes

DF11, DF17, DF18, DF19

Pulse and spectral characteristics of


acc. to Annex 10, Vol. 4
transmitted signal
Interface

2 x LAN, single output to measuring unit (75 driver)

Autonomous feature (option)

Transmission of preset charts stored in FLASH


internal memory.

Diagnostics

LED PWR detection of transmitted power and


received commands from CPS.
LED SWR detection of wrong load matching.

Mechanical parameters
W x H x D (w/o holders and
connectors)

147 mm x 465 mm x 291 mm

Weight

16.5 kg

Datasheet

Operating conditions

Ambient conditions

Environmental effects

EMC

Mechanical conditions

Module T02-1400

Tested according to

Temperature range
-40 C +60 C

SN ETS 300 019-2-4, class 4.1 E

Humidity
rh < 0 %, 100 % >

SN ETS 300 019-2-4, class 4.1 E

IP67

MIL-STD-810F/METHOD 512.4

Salt mist

MIL-STD-810F/METHOD 509.4

Fungi (microbes)

MIL-STD-810F/METHOD 508.5

Convenient

EMI - SN EN 61000-6-3
EMS - SN EN 61000-6-2

Sinusoidal vibrations
(a 1 g, f 200 Hz)

SN ETS 300 019-2-4, class 4.1 E


SN EN 60068-2-6 Fc, class 4M5

Impacts (a 25 g)
Impact duration 6
ms

SN ETS 300 019-2-4, class 4.1 E


SN EN 60068-2-29, class 4M5,
method Eb

Storage conditions
Climate specification

-50 C +70 C

SN EN 60068-2-14 Nb

Reliability
MTBF

10 000 hours

Module T02-1400

Datasheet

Subject Illustration with Particular Parts Labeling

Figure 5-1 T02-1400 Module Drawing

Datasheet

Figure 5-2 T02-1400 Module 3D view

10

Module T02-1400

Module T02-1400

Datasheet

List of Connection Points


Label

Description
Power supply

Signal mains failure (power supply fault)

Input

Harting HAN 8D connector Male

Input/Output

Ethernet RJ45 connector (Harting HAN 3 A connector).

Input/Output

Ethernet RJ45 connector (Harting HAN 3 A connector).

Not used

Output

RF signal to transmission antenna (N-f connector).

Output

75 TTL driver HAN 8D Female.

Input/Output

Service connector (ECTA 133 connector).

List of Indicators
LED PWR
LED color
Color

Condition

green

Full transmission power.

orange

Decreased transmission power (default by 3 dB).

red

Transmission turned out in consequence of error.

LED flickering
Flickering
period [s]

Lighting
period [s]

Lighting
brightness

0.75

full

command from Master XPort


(connector 2) and main port

0.25

full

command from Master XPort


(connector 2) and reserve port

0.75

decreased

command from Slave XPort


(connector 3) and main port

0.25

decreased

command from Slave XPort


(connector 3) and reserve port

full

last received data transmitted


during timeout (10 s) (no data
from any CPS)

full

no transmission (no data from any


CPS, and timeout expiry)

permanently on

Condition

11

Datasheet

Module T02-1400

LED SWR
Color
green
red

Condition
SWR in good order transmission is running.
SWR error (RL < ~6 dB) no transmission.

Indication and Localization of Error Conditions


Indication and localization of error conditions occurs in two ways:
1) With the help of LED PWR and LED SWR described in chapter 7.
2) They are transferred to the CPS in a diagnostic message.
Following diagnostic information is transmitted:
POW
Output power failure.
PSV
SWR too high.
PUL
Output pulses failure.
ERR
TXLU block failure.
NTP
Communication error with SNTP server.
CP
Space factor too high.
DAT
Data not running.
UPS
Operation from UPS.

List of Setup and Control Elements


The equipment lacks adjusting and control elements accessible for the
customer.

10

List of Diagnostic Outputs


No diagnostic outputs are accessible to the customer.

12

Module T02-1400

11

Datasheet

Replacement Procedure

Holders

Locking screw

Figure 111 T02-1400 Module Replacement

11.1

Disassembly

11.2

Remove shrink connector protections.


Disconnect feeder cable, antenna cable and LAN cables.
Disconnect grounding cable.
Slacken safety bolt, see picture.
Shift entire module upright.
Remove module from the cabinet.

Assembly

Insert module to the cabinet and hang it in appropriate position.


Tighten safety bolt.
Connect grounding cable.
Connect LAN cables, antenna cable and feeder cable.
Mount shrink connector protections.
Set IP address and NTP server addresses acc. to chapter 11.3.

13

Datasheet

11.3

Module T02-1400

T02-1400 Module IP Addresses and NTP Server Addresses


Setting after Replacement
The setting can be performed before or after the module replacement. In both
cases, the wiring diagram shown in Figure 112 shall apply.

Supply 24V=

T02-1400

Figure 112 Wiring diagram of T02-1400 module in the system

ANT
PC
S01
T02-1400

Antenna.
RMT or MNB computer.
Module S01 (power supply).
Module T02-1400 being set up.

During the set up operation, the T02-1400 module own IP address as well as
the actual addresses of the NTP server shall be stored into the T02-1400
module memory.
The IP address setting and other network XPort parameters setting of the
T02-1400 module may be executed by a qualified person only and after
consulting the network administrator.

14

Module T02-1400

Datasheet

Setting up the IP Address


Run the Lantronix DeviceInstaller program version 3.6.0.6 from archive
\\era_nt_server2\6000\vykrarch\Sw\EZ0100A\EZ0100A00114_XX\TXLU_2_XPORTS_IQMO
D_XX.zip (XX is actual fw version number, for example 00). Then press

the Assign IP button, and in opened window, complete MAC address


of XPort to the red labeled field (see Figure 113); the address is designated
on the XPORT2 label stuck on the T02-1400 module.

Figure 113 Entering MAC address of XPort in Lantronix DeviceInstaller program

Press the Next button, and select the Assign item and specific IP address in
the next window (see Figure 114).

Figure 114 Lantronix DeviceInstaller window Assignment Method

15

Datasheet

Module T02-1400

Press the Next button again, and fill in values of the network connection
setting in the IP address, Subnet Mask and Default Gateway fields (see
Figure 11-5).

Figure 115 Window for entering network parameters of XPort in Lantronix


DeviceInstaller program

Press the Assign and then press the Finish (see Figure 116).

Figure 116 Lantronix DeviceInstaller window Assignment finish

Repeat the same procedure for the XPort, address of which is on the
XPORT3 label of the T02-1400 module.

16

Module T02-1400

Datasheet

Setup the address of the NTP server


After setting the T02-1400 module own IP address, press the Search button
in the Lantronix DeviceInstaller program version 3.6.0.6, and XPorts list
connected to the local network shall appear in the program window. In the left
window, XPorts with IP address shall be successively selected.
Press the Connect button on the Telnet Configuration flag, and after the
Enter key pressing, XPort Setup Mode shall appear (see Figure 117).
Select the NTP Setup item (button 2) and enter the actual IP address of the
NTP server and of the reserve NTP server. Save changes, and quit the
Setup Mode by means of button 9 save and exit.

Figure 117 Setup Mode of XPort in Telnet

17

Datasheet

11.4

Module T02-1400

Procedure of Output Power Decrease and SWR Monitoring


Turning out on Frequency of 1090 MHz
This procedure serves for decreasing output power to approx. 100 W and
turning out the SWR monitoring on the frequency of 1090 MHz so that the
T02-1400 module could be used together with transmitting antenna, which
has wrong matching on 1090 MHz. This configuration must be performed at
turned out transmission (by a command from CPS) of configured block!!!
1) Wiring at the configuration is similar to Figure 112.
2) Following file shall be expanded on the computer hard disk:
\\era_nt_server2\6000\vykrarch\Sw\EZ0100A\EZ0100A00114_XX\TXL
U_2_XPORTS_IQMOD_XX.zip (XX is a number of fw actual version,
e.g. 00), which contains firmware of the TXLU transmitter and
configuration files.
3) In the Windows system command line (Start Execute enter cmd to
the opened window and confirm by OK button), following file shall be
executed: $\T02_700_SWR_1090_off.bat xxx.xxx.xxx.xxx, where $ is a
path to the directory created after following file expansion:
\\era_nt_server2\6000\vykrarch\Sw\EZ0100A\EZ0100A00114_XX\TXL
U_2_XPORTS_IQMOD_XX.zip (e.g. c:\TXLU_2_XPORTS_IQMOD_00)
and xxx.xxx.xxx.xxx is an IP address of the XC2 Xport.
4) A short-time disconnection of configured block from the power supply
shall be carried out. If such disconnection cannot be realized, Lantronix
DeviceInstaller version 3.6.0.6 shall be executed, application of which is
described above, and the above mentioned procedure shall be
performed except for the NTP Setup item selection and consecutive
entering addresses of NTP servers.
5) To return the block eventually to its original status, the procedure from
point 3) shall be repeated, while instead of
T02_700_SWR_1090_off.bat, the T02_700_SWR_1090_on.bat shall be
executed.

18