Professional Documents
Culture Documents
PWR4/10
Bus 4
PWR5/11
Bus 6/Out
PWR3/9
Bus 2
Sync OUT
PWR6/12
FEPD LED
PWR
PWR1/7
EAC
V48 (+/-)
Bus 1
SS
Sync IN
FPA
Caution,
Hot
Surface
LED (ESMA)
Electrostatical
sensitive
device
FIxA LED
Interchangeable Transport module:
8xE1, 8xE1/T1, 2x Flexbus,
4xE1+2xFE+1xGE or 4xE1T1+2xFE+1xGE
Q1
LMP
Electrostatical
sensitive
device
Figure 8.
DN70247197
Issue 3 en
19/06/2008
DN7073143
17 (41)
Table 5.
Connector type
Interface(s)
V48N (+/-)
MDR 26 F RA
EAC*
MDR 36 F RA
Sync OUT
MDR 14 F RA
External BTS
Sync IN
MDR 26 F RA
SS
RJ45
FPA
RJ45 shielded
Q1
Q1 management interface
RJ45 shielded
Nokia Q1 managed
network elements
LMP
RJ45 shielded
* The alarm outputs 5 & 6 are open collector circuits. The outputs are in
floating state with no load (relays not connected). Load is needed for
output testing. Usually relays are connected between the alarm outputs
and the alarm power supply outputs 5 & 6.
18 (41)
DN70247197
Issue 3 en
19/06/2008
2M signal
output
2M signal
input
2M signal
output
ground
ground
ground
ground
Tx8 Rx8
Tx6 Rx6
Tx7 Rx7
Tx3 Rx3
Tx5 Rx5
Tx4 Rx4
Tx1 Rx1
Tx2 Rx2
LED
Electrostatical
sensitive device
DN70165032
Figure 9.
Table 6.
Connector type
Interface(s)
SMB
External transmission
equipment
DN70247197
Issue 3 en
19/06/2008
19 (41)
LED
FB1
LED
FB2
Electrostatical
sensitive device
Figure 10.
Table 7.
DN70165044
Connector type
Interface(s)
FB1, FB2
TNC
Nokia FlexiHopper
microwave radios
20 (41)
DN70247197
Issue 3 en
19/06/2008
876 54321
IF8
IF7
IF6
IF5
1
2
3
4
5
6
In In +
Gnd
Out Out +
Gnd
IF4
IF3
IF2
IF1
LED
Electrostatical
sensitive device
Figure 11.
Table 8.
DN70165056
Connector type
Interface(s)
RJ48 shielded
External transmission
equipment
DN70247197
Issue 3 en
19/06/2008
21 (41)
IF2
EIF3
EIF1
FIQA
IF3
EIF2
IF1
Electrostatical
sensitive
device
LED
Caution,
Hot
Surface
DN70540929
Figure 12.
Table 9.
Label name on
module
Description
Connector type
Interface(s)
IF1 ... IF 4
Four transmission
(Abis) interfaces balanced E1/T1
RJ48 shielded
External
transmission
equipment
22 (41)
DN70247197
Issue 3 en
19/06/2008
Table 9.
Label name on
module
Description
Connector type
Interface(s)
Two PWE
transmission (Abis)
interfaces 100Base-T (Fast
Ethernet)
RJ48 shielded
Ethernet/IP based
packet switched
network
EIF3
One PWE
transmission (Abis)
interfaces 1000Base-SX or
1000Base-LX
(Gigabit Ethernet)
requires additional
SFP module
EIF3
Tx2 Rx2
EIF1
FIYA
Tx3 Rx3
Tx1 Rx1
EIF2
Electrostatical
sensitive
device
LED
Caution,
Hot
Surface
Figure 13.
DN70247197
Issue 3 en
19/06/2008
DN70540932
23 (41)
Table 10.
Label name on
module
Description
Connector type
Interface(s)
Four Transmission
(Abis) interfaces unbalanced
(coaxial) E1
SMB
External
transmission
equipment
Ethernet/IP based
packet switched
network
24 (41)
Two PWE
transmission (Abis)
interfaces 100Base-T (Fast
Ethernet)
RJ48 shielded
EIF3
One PWE
transmission (Abis)
interfaces 1000Base-SX or
1000Base-LX
(Gigabit Ethernet)
requires additional
SFP module
DN70247197
Issue 3 en