Contents

Contents
Water Applications: Water Transport .............................................................................................................. 4
Submersible Pump in Discharge Tube ........................................................................................................................... 4
Amacan K ................................................................................................................................................................... 4
Main applications ................................................................................................................................................ 4
Fluids handled ...................................................................................................................................................... 4
Operating data ....................................................................................................................................................4
Designation .......................................................................................................................................................... 4
Design details ....................................................................................................................................................... 4
Materials ..............................................................................................................................................................4
Coating and preservation ...................................................................................................................................5
Product features / customer benefits ................................................................................................................. 5
Acceptance tests / warranties .............................................................................................................................5
Selection information .......................................................................................................................................... 5
Overview of product features / selection tables ................................................................................................ 6
Table of fluids handled .................................................................................................................................6
Overview of product features ....................................................................................................................... 7
Motor sizes per pump .................................................................................................................................... 8
Specifications required for inquiries/orders ....................................................................................................... 9
Material combinations ......................................................................................................................................10
Related documents ............................................................................................................................................ 10
Selection chart ...................................................................................................................................................11
Amacan K, n = 1160 / 875 / 700 rpm ........................................................................................................... 11
Characteristic curves .......................................................................................................................................... 12
n = 1160 rpm ................................................................................................................................................ 12
n = 875 rpm .................................................................................................................................................. 16
n = 700 rpm .................................................................................................................................................. 25
Dimensions ......................................................................................................................................................... 27
UG/XG motors (700-324 to 800-401) [inch] ................................................................................................. 27
UNG/XNG motors (800-370 to 1200-630) [inch] .........................................................................................29
UG/XG motors (700-324 to 800-401) [mm] .................................................................................................31
UNG/XNG motors (800-370 to 1200-630) [mm] .......................................................................................... 33
Types of installation ..........................................................................................................................................35
Scope of supply .................................................................................................................................................. 35
Accessories ......................................................................................................................................................... 36
Pump with support rope and turnbuckle in the discharge tube ..............................................................36
Discharge tube cover with cable gland ......................................................................................................37
General assembly drawings with list of components ...................................................................................... 39
Amacan K 700 - 324 ... 800 - 401, motor version: UG/XG ..........................................................................39
Amacan K 800 - 330 ... 800 - 401, motor version: UG/XG ..........................................................................40
Amacan K 800 - 370 ... 1200 - 630, motor version: UNG/XNG ...................................................................41

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Water Applications: Water Transport

Code
8

Submersible Pump in Discharge Tube


UN

Amacan K

Description
Number of motor poles
6 6-pole
8 8-pole
10 10-pole
Motor version
U Without explosion protection, standard
(sizes 700-324 ... 800-401)
X Explosion protection to NEC 500
(sizes 700-324 ... 800-401)
UN Without explosion protection, standard
(sizes 800-370 ... 1200-630)
XN Explosion protection to NEC 500
(sizes 800-370 ... 1200-630)
Material variant
G Impeller made of gray cast iron, standard
design
G1 Like G with impeller made of duplex stainless
steel

Design details
Design
Fully floodable submersible pump in discharge tube
(submersible motor pump)
Not self-priming
Close-coupled design
Single-stage
Vertical installation

Main applications
Irrigation and drainage pumping stations
Stormwater pumping stations
Water pollution and flood control

Fluids handled
Waste water

Drive
Three-phase asynchronous squirrel-cage motor
Version with explosion protection to NEC 500: explosion-proof
for Class I, Division 1, Groups C and D, T3, hazardous (classified)
locations

Shaft seal

Sludge

Two bi-directional mechanical seals in tandem


arrangement, with liquid reservoir

Surface water
Stormwater
Waste water

Impeller type
Closed multichannel impeller
(impeller type K)

Operating data
Operating properties
Characteristic
Flow rate
Head
Motor rating
Fluid temperature

Q
H
P2
t

Value
22,000 US gpm [5000 m3/h]
Up to 80 ft [24.4 m]
Up to 350 hp [261 kW]
Up to 104 F [40 C]

Bearings
Grease-packed rolling element bearings

Designation
Example: Amacan K 800-400 / 50 8 UN G

Materials

Key to the designation

Description
Pump casing
Motor housing
Shaft
Impeller
Casing wear ring
Screws, bolts, nuts

Code
Amacan
K
800
400
50

Description
Type series
Impeller type, e.g. K = channel impeller
Nominal diameter of the discharge tube [mm]
Nominal impeller diameter [mm]
Motor size

Amacan K

Suitable for the following


fluids
Contaminated, solids-laden,
non-gaseous fluids without
stringy material

Overview of materials
Material
A 48 Class 40 B
A 48 Class 40 B
A 576 Gr. 1045 / A 276 Type 420
A 48 Class 40 B / A 890 CD 4 MCu
A 48 Class 40 B / AISI 329
Stainless steel

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Coating and preservation
Paint
Surface treatment: SA 2 1/2 (SIS 055900) AN 1865
Primer: primer coat on unfinished casting
Top coat: environmentally friendly KSB standard coating
(RAL 5002)

Special coating
Available on request (extra charge and a longer delivery
period apply).

Product features / customer benefits


Efficient use of power thanks to three-phase motor and
optimum motor cooling by fluid handled.
Easy to install as pump's own weight ensures selfcentering seating in the discharge tube, and an O-ring
seals it. Quick to install or remove without any additional
anchoring or anti-rotation elements.
Slim motor minimizes discharge tube flow losses.
High reliability provided by bearing temperature
monitoring, vibration sensor, thermal motor protection,
leakage sensors in the motor and connection space, and
leakage monitoring of the mechanical seal system.
Low-vibration hydraulic system; inlet ribs and optimized
bellmouth for vortex-free inflow.
Absolutely water-tight resin-sealed cable entries prevent
any water from entering the motor even in the event of
a damaged cable.

Acceptance tests / warranties


Functional test
Every pump undergoes functional testing to KSB standard
ZN 56535.
Operating data is guaranteed to DIN EN ISO 9906/2/2B or
Hydraulic Institute Level B.

Acceptance tests
Acceptance tests to ISO/DIN or a comparable standard are
available against a surcharge.

Warranties
Quality is assured by means of an audited and certified
quality assurance system to DIN EN ISO 9001.

Selection information
Information for pump selection
The guaranteed point of submersible pumps in discharge tubes
is measured at a head of 1.65 ft [0.5 m] above the motor. The
documented characteristic curves refer to this data. This must
be taken into account when calculating system losses. The
indicated heads and performance data apply to pumped fluids
with a density = 7.48 lbs/ft3 [1 kg/dm3] and a kinematic
viscosity of up to 20 mm2/s.

1)

The pump input power must be matched to the density of the


fluid handled:
P2req. = fluid [kg/dm3] x P2docu
The operating point with the largest pump input power is
decisive for the operating range of the motor. To compensate
the unavoidable tolerances of the characteristic curves of
system and pump we recommend selecting a motor size which
provides sufficient power reserves.
Recommended minimum reserves1)
Required pump input
power

Motor power reserve

[hp]

[kW]

Mains operation

40
> 40

30
> 30

10 %
5%

With frequency
inverter
15 %
10 %

Determine the minimum water level t1min (diagram in general


arrangement drawing):
The minimum water level t1min is the water level required in the
pump's suction chamber to ensure the following:
The hydraulic system (impeller) is sufficiently submerged
(shown in diagram depending on pump size).
The pump does not draw in air-entraining vortices (shown
in diagram depending on flow rate).
The hydraulic system is free from cavitation (check against
the NPSHrequired value in the technical literature. The
following conditions must be met:
NPSHavailable > NPSHrequired + safety margin
NPSHavailable = 10.0 + (t1 - t2)
Safety margin:
up to Qopt 1.65 ft [0.5 m]
larger than Qopt 3.3 ft [1.0 m]

Head (H)
The total pump head is composed as follows:
H = Hgeo + HV
Hgeo (static head)
Without discharge elbow Difference between suctionside water level and overflow edge
With discharge elbow Difference between suction-side
and discharge-side water level
HV (losses in the system)
Starting 1.65 ft [0.5 m] downstream of the pump: e.g. pipe
friction, elbow, swing check valve, etc.

Losses by inlet, riser and elbow


Losses are caused by the inlet, riser and elbow (or free
discharge).
Losses in the riser up to the indicated reference level
(1.65 ft [0.5 m] above the motor) are taken into account in
the documented characteristic curves.
Inlet and elbow losses are system losses and must be taken
into account for selection.
For information on structural requirements, pump
installation and pump sump design please refer to the KSB
know-how brochure "Planning Information: Amacan
Submersible Pumps in Discharge Tubes" 0118.55.

If larger reserves are stipulated by local regulations or are required to compensate for uncertain factors in system
calculations, these larger reserves must be provided.

Amacan K

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Overview of product features / selection tables
Table of fluids handled
The table below for your guidance is based on KSB's longstanding experience. The data are standard values and are not
to be considered as generally binding recommendations. More
detailed advice is available from our specialist department in
Halle. Make use of our laboratory's expertise when selecting
materials.

Fluid handled2) (fluids not containing stringy


substances)
Gray water
River water
Stormwater
Waste water
Activated sludge
Industrial waste water containing ...
- Paint suspensions
- Lacquer/paint/varnish suspensions
- Fibers/pulp
- Chips/swarf
- Abrasive substances
Mildly acidic industrial waste water

Information, recommendations
Free passage > any solids contained,
possibly pre-cleaned via a screen or weir
Pre-cleaned via a screen or weir
Pumpable up to a dry substance content of 3 %
Solvent-free, observe the operating instructions!
Solvent-free, contact KSB to handle silicone-free fluids.
Fluids containing short fibers, no stringy material
Material variant G1, special mechanical seal, solids content < 5 g/l
pH value 6.0: material variant G1 and special coating
pH value < 6.0: contact KSB (for material variant C)

Neutral non-corrosive waste water


- Ammonium hydroxide
- Ammonium hydroxide 5 % NH4OH
- Urea 25 % (NH2)2-CO
- Potassium hydroxide 10 % KOH
- Calcium hydroxide 5 % Ca(OH)2
- Sodium hydroxide 5 % NaOH
- Sodium carbonate 30 % Na2CO3
Neutral, non-corrosive waste water containing ...
- Aliphatic hydrocarbons, e.g. oils, petrol, butane,
methane
- Aromatic hydrocarbons, e.g. benzene, styrene
- Chlorinated hydrocarbons, e.g.
tetrachloroethylene, ethylene chloride,
chloroform, methylene chloride

2)

FPM (Viton) O-rings, for high concentrations contact KSB.

Fluids to be pumped which are not listed in this table usually require higher-grade materials. Contact KSB.

Amacan K

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Overview of product features
Overview of product features, material variants G, G1
Feature

Motor version
U/X

Motor size
6-pole
8-pole
10-pole
Shaft material
Shaft
Shaft protecting sleeve
Bearings

Motor
Explosion protection, version U ...
Explosion protection, version X ...
Starting method
Voltage
Cooling
Immersion depth
Power cable
Type
Length
Cable entry
Sealing elements
Elastomer seals
Shaft seal
Monitoring equipment
Winding temperature, version U ...
Winding temperature, version X...
Bearing temperature
Motor leakage
Mechanical seal leakage
Vibration sensor
Coating
Installation types
Maximum temperature of fluid
handled
Tests/inspections
Hydraulic system
General

20 6
10 8, 17 8
-

UN/XN

26 6
21 8
-

32 6 ... 50 6
26 8, 35 8
-

A 276 Type 420


Grease-packed rolling element bearings
sealed for life

60 6
50 8
-

80 6
75 8 ... 260 8
40 10 ... 150 10

A 576 Gr. 1045


A 276 Type 420
(C 45 N)
(1.4021)
A 276 Type 420 (1.4021)
Pump end: re-greasable rolling element
bearings
drive end: grease-packed rolling element
bearings sealed for life

Not explosion-proof
or
Explosion-proof Class I, Division 1, Groups C & D, T3
DOL, soft starter, frequency inverter or starDOL, soft starter, frequency inverter
delta
460 V3)
Cooled by surrounding fluid
100 ft [30 m] max.
See table "Overview of power cables"
33 ft [10 m]4)
Absolutely watertight
Nitrile butadiene rubber NBR5)
Bellows-type mechanical seal6)
Temperature switch (bimetal) in the winding
Temperature switch (bimetal) in the winding, plus PTC for explosion protection
-7)
PT100 on pump end7)
Electrode monitoring the winding space for
Electrode monitoring the winding and
leakage
connection space for leakage
Float switch in leakage area
-8)
Environmentally friendly KSB standard coating, color RAL 50029)
( Page 35)
104 F[40 C]

KSB standard (ZN 56525)10)


KSB standard (ZN 56525)

Overview of power cables


Feature
Type
Rated voltage
EMC screening

3)
4)
5)
6)
7)
8)
9)
10)

S1BN8-F
rubber-sheathed cable
Standard
1000 V
-

S07RC4N8-F
rubber-sheathed cable
Optional
750 V

Optional: 230 V, 380 V, 575 V


Optional: up to 165 ft [50 m]
Optional: Viton = fluorocarbon rubber FPM
Optional: mechanical seal with covered spring
Optional: PT100 on pump end
Optional: internal vibration sensor
Optional: 10 mils [250 m]
Optionally to Hydraulic Institute, Level A

Amacan K

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Feature

S1BN8-F
rubber-sheathed cable

S07RC4N8-F
rubber-sheathed cable

EPR11)
194 F [90 C]

EPR11)
194 F [90 C]

Insulation material
Max. continuous temperature of insulation
For permanent immersion in waste water to DIN VDE 0282-16/HD22.16

Motor sizes per pump


Overview of motor sizes per pump
Pump size

Motors

1
2
3

11)

3
3 3
- 3
-

150 10

2
2
-

110 10

2
2
2
-

90 10

50 8

1
1
1
1
-

75 10

35 8

1
1
1
1
1
-

60 10

26 8

1
1
1
1
-

40 10

21 8

3
-

260 8

17 8

3
3
-

220 8

10 8

2
2
2
-

185 8

80 6

2
2
2
2
-

150 8

60 6

2
2
2
-

130 8

50 6

1
1
1
-

110 8

40 6

1
1
-

10-pole

90 8

32 6

75 8

26 6

K 700-371
K 700-324
K 700-330
K 800-330
K 800-370
K 800-371
K 800-400
K 800-401
K 1000-420
K 1000-500
K 1200-630

8-pole

20 6

6-pole

3
-

3
-

3
3

3
-

3
3

3
3

General assembly drawing Amacan K 700 - 324 ... 800 - 401, motor version: UG/XG ( Page 39)
General assembly drawing Amacan K 800 - 330 ... 800 - 401, motor version: UG/XG ( Page 40)
General assembly drawing Amacan K 800 - 370 ... 1200 - 630, motor version: UNG/XNG ( Page 41)

EPR = ethylene propylene rubber

Amacan K

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Specifications required for inquiries/orders

1 Suspension arrangement attached to cover (or cross beam


for BU/BG)
2 Lifting ring (standard, included in the scope of supply)
3 Optional (intermediate) lifting ring(s)
4 Lower edge of discharge tube

Designation of the pump (see section Designation)


Flow rate Q, head Htotal
Type and temperature of fluid handled
Voltage, frequency, starting method, cable length

The support rope is an accessory and can be supplied with


additional lifting rings and a support spacer as an option. (
Page 36) The standard design is supplied without intermediate
lifting ring(s).

Quantity and language of operating manuals


Required accessories
For discharge tubes indicate all required elevations
and the type of installation.
For flow-straightening vanes indicate the type of
installation and whether the design is with or without
suction umbrella.
For a support rope indicate dimension "L", the
number of additional lifting rings (depending on the
lifting height of the lifting equipment) as well as the
elevations and type of installation.
Always define dimension "L" when ordering a support rope to
allow the correct length to be determined. The lifting height
of the crane must be taken into account when ordering a
support rope. This determines the number of lifting rings
required for installing the pump in or removing it from the
discharge tube.

Amacan K

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Material combinations
Overview of materials per material variant
Part No.
101
163
230
350 / 330
412

Description
Pump casing
Discharge cover
Impeller
Bearing housing / bearing bracket
O-ring

433

Mechanical seal (pump end)


Mechanical seal (drive end)
Casing wear ring

502
525
571
811
812
818
834

Shaft protecting sleeve15)


Bail
Motor housing
Motor housing cover15)
Shaft (rotor)
Cable gland
Cable gland housing
Various
Screws/bolts
Other materials on request.

G1
A 48 Class 40 B
A 48 Class 40 B

A 48 Class 40 B

A 890 CD 4 MCu
A 48 Class 40 B
NBR12)
(Viton-FPM)13)
SiC/SiC (bellows NBR12), Viton - FPM13))
Carbon / SiC (bellows NBR12), Viton - FPM13))
A 48 Class 40 B / AISI 32914)
A 276 Type 420
A 536: 60-40-18 /A 284 B16)
A 48 Class 40 B
A 48 Class 40 B
A 276 Type 420 / A 576 Gr. 104517)
A 48 Class 40 B
Stainless steel

Related documents

Comparison of materials
EN
EN-GJL-250 (JL 1040)
1.4517
1.4021
C 45 + N
VG 434
NBR
FPM
EN-GJS-400-15 (JS1030)
S235JR

ASTM
A 48 Class 40 B
A 890 CD 4 MCu
A 276 Type 420
A 576 Gr. 1045
AISI 329
NBR
FKM
A 536: 60-40-18
A 284 B

General Arrangement Drawings 1579.396


Motor Data Booklet 1579.536
Planning Information 0118.55

JL 1040 gray cast iron (lamellar graphite cast iron)


Lamellar graphite cast iron to DIN 1691 is the most widely used
cast material for handling municipal sewage, waste water and
sludges as well as stormwater and surface water. It is suitable
for neutral fluids which are only slightly aggressive and cause
little wear. The ph-value should be 6.5, the sand content
0.5 g/l.
Duplex stainless steel (1.4517 or technically equivalent
material)
This type of cast steel is resistant to cavitation, has excellent
strength values and is used for high circumferential speeds. An
excellent resistance to pitting corrosion makes ferriticaustenitic stainless steel a popular choice for pumping acidic
waste water with a high chloride content as well as seawater
and brackish water. Thanks to its good chemical resistance, e.g.
also against waste water containing phosphorous and
sulphuric acid, this material is used in a wide range of
applications in the chemical industry and process engineering.
Pumps made of duplex stainless steel have a very long service
life, even when handling brines, chemical waste water (pH 1
12), gray water and landfill leachate.

12)
13)
14)
15)
16)
17)

10

Nitrile rubber (Perbunan)


FPM fluorocarbon rubber variant available as an option against a surcharge
This option is available against a surcharge.
Not available for all sizes
A536: 60-40-18 for motors: 60 6 ... 80 6, 50 8 ... 130 8, 40 10 ... 90 10; A 284 B for motors: 150 8 ... 260 8, 110 10 ... 150 10
For further information see "Overview of product features"

Amacan K

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Selection chart
Amacan K, n = 1160 / 875 / 700 rpm
200

400

300

Q [l/s]

100

80

Q [m 3/h]

500

2000

1000

200

300

400

3000

4000

5000

1000

500

20

700/80 0--371
6 pol

50

800--370
6 pol

10

800--401
6 pol

700/800--330
6 pol

30

20

1200--630
8 pol

1000--500
8 pol

40

700--324
8 pol

700--371
8 pol

1000--420
8 pol
800--400
800--401
8 pol

700-330
8 pol
10

1200--630
10 pol

1000--500
10 pol

2
5

H
[m]

1
3
H
[ft]
2
800

1000

Q[US.gpm]
1000

2000

Q [IM.gpm]

3000
2000

4000
3000

5000
4000

10000
5000

20000
10000

30000
20000

Amacan K

11

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Characteristic curves
n = 1160 rpm

Amacan K 700-330 / 800-330, n = 1160 rpm


Characteristic curves to ISO 9906 / 2 / 2B. The characteristic
curves correspond to the effective motor speed.

200 Q [m3/h] 400

600

100

800

Q [l/s]

1000

200

1200
300

60

Qmin
60

65
70

40

60

75
65

[%]

78

70
75

H [ft]
60

65

20

80.1
80

70

79.8
75

60

65

70
70

70
65

Q [IM.gpm]

2000

1000

3000
2000

75

75

75
71.1

0 Q [US.gpm] 1000

78

78

75.9
70

10

80

78

60

65

60

242

H [m]

70
65

266

4000

65
60

296

60

326

0
6000

5000

3000

4000
30

40

P [kW]
P [hp]

326

20

20

296
266
242

0 Q [US.gpm] 1000

2000

3000

4000

5
5000

6000
K42273--1

Free passage

2 3/4 [70 mm]

Rated power P2 and mass moment of inertia


Size

Rated power P2

700-330 / 20 6 U / X
700-330 / 26 6 U / X

18)

12

[hp]

[kW]

24
30

17.9
22.4

Size
J18)
Mass moment
of inertia J
[kgm2]
0.55
0.58

800-330 / 32 6 U / X
800-330 / 40 6 U / X

Rated power P2
[hp]

[kW]

40
50

29.8
37.3

These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan K

Mass moment
of inertia J
[kgm2]
0.79
0.87

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Amacan K 700-371 / 800-371, n = 1160 rpm
Characteristic curves to ISO 9906 / 2 / 2B. The characteristic
curves correspond to the effective motor speed.

500

100

1000

Q [m3/h]
Q [l/s]

200

1500
300

400

80

Qmin
60

20

60
70
77

70
75

60

40

70

70

20

70.8

74.3

55

0 Q [US.gpm]1000
0 Q [IM.gpm]

2000

1000

75

70

278

3000

10

75
70

75

70

2000

77

77

7777.1
77

60

77.3

75

70

60

H [m]

78.4
77

60

H [ft]

[%]

75

60

70
70

3000

60

323

300

4000

60
60

5000

370

350

4000

5000
40

370

40
P [hp]

350

20

P [kW]

20

323
278

6000

0 Q [US.gpm] 1000

Free passage

2000

3000

4000

300

5000

6000

K43173--0

4 1/8 [105 mm]

Rated power P2 and mass moment of inertia J19)


Size

Rated power P2

700-371 / 20 6 U / X
700-371 / 26 6 U / X
800-371 / 32 6 U / X
800-371 / 40 6 U / X
800-371 / 50 6 U / X

19)

[hp]

[kW]

24
30
40
50
65

17.9
22.4
29.8
37.3
48.5

Mass moment
of inertia J
[kgm2]
0.65
0.68
0.89
0.97
1.06

These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan K

13

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Amacan K 800-370, n = 1160 rpm
Characteristic curves to ISO 9906 / 2 / 2B. The characteristic
curves correspond to the effective motor speed.

0
100

500

100

1000

Q [m3/h]
Q [l/s]

200

1500
300

400
30

H [m]

Qmin

80

60
70

60

75

78

70

H [ft]

60

40

60

70

75

78

82
80

75

82.2

82

81.4

75

70

80

78
78.6
78
75
70

70

0 Q [US.gpm]1000
0

2000

Q [IM.gpm] 1000

3000
2000

4000
3000

70

75
70

70

290

10

75

78

75

20

78

80

76.7

20

[%]

80

60

310

5000

370

340

6000

4000

7000

5000

60
P [hp]

370

40
P [kW]

40
340

20
20

290

0 Q [US.gpm]1000

2000

3000

4000

310

5000

6000

7000
K43174--0

Free passage

3 3/8 [85 mm]

Rated power P2 and mass moment of inertia J20)


Size

Rated power P2

800-370 / 26 6 U / X
800-370 / 32 6 U / X
800-370 / 40 6 U / X
800-370 / 50 6 U / X
800-370 / 60 6 UN / XN

20)

14

[hp]

[kW]

30
40
50
65
80

22.4
29.8
37.3
48.5
59.7

Mass moment
of inertia J
[kgm2]
0.63
0.84
0.92
1.01
1.16

These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan K

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Amacan K 800-401, n = 1160 rpm
Characteristic curves to ISO 9906 / 2 / 2B. The characteristic
curves correspond to the effective motor speed.

0
90

500

1000

Q [m3/h]
200

1500
Q [l/s]

2000

400

2500
600

80

Qmin

20

65

60

70
73

H [ft]

65

65

40
65

70

[%]

75

73
75

77.2

70
73

77

76

70
73

74.4

100

2000 Q [US.gpm] 4000

2000

6000

Q [IM.gpm] 4000

70

70

70

331

73

73

73
70

10

75

75

73.3
73

20
10

H [m]

77

350

371

8000
6000

393

10000
8000

80

393

P [hp]

60
P [kW]

60

371

40
350

40
25

331

20
0

Free passage

2000 Q [US.gpm] 4000

6000

8000

10000

K43177--0

5 5/16 [135 mm]

Rated power P2 and mass moment of inertia J21)


Size

Rated power P2

800-401 / 40 6 U / X
800-401 / 50 6 U / X
800-401 / 60 6 UN / XN
800-401 / 80 6 UN / XN

21)

[hp]

[kW]

50
65
80
107

37.3
48.5
59.7
79.8

Mass moment
of inertia J
[kgm2]
1.17
1.26
1.41
1.55

These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan K

15

Water Applications: Water Transport


Submersible Pump in Discharge Tube
n = 875 rpm
Amacan K 700-324, n = 875 rpm
Characteristic curves to ISO 9906 / 2 / 2B. The characteristic
curves correspond to the effective motor speed.

0
40

Q [m3/h]

200

400

600

100

800

Q [l/s]

1000

200

300

10

Qmin

30

60

65

H [ft]
60

70
78

70

20
60

65

75

65

80

75

81.1

78

70
75

78.8

10

78

1000

Q [US.gpm]

1000

2000

Q [IM.gpm]

78

70

3000
2000

70

75
70

24

75

78
75

80

79.7
78

H [m]

[%]

65

65
65

295

324

262

4000

5000

3000

4000
16

20
P [kW]
324

P [hp]

10
295

10
262

1000

Q [US.gpm]

2000

3000

4000

6
5000
K42185--1

Free passage

2 3/4 [70 mm]

Rated power P2 and mass moment of inertia J22)


Size

Rated power P2

700-324 / 10 8 U / X
700-324 / 17 8 U / X

22)

16

[hp]

[kW]

13
22

9.7
16.4

Mass moment
of inertia J
[kgm2]
0.54
0.57

These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan K

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Amacan K 700-330, n = 875 rpm
Characteristic curves to ISO 9906 / 2 / 2B. The characteristic
curves correspond to the effective motor speed.

0
40

200

Q [m3/h]

50

Q [l/s]

400

600

100

800

150

200

250

10

Qmin

30

60

60

20

65

65

H [m]

70

[%]

75
78

70
75

60

H [ft]

65

60

79.2
75

65

10

70

78

78
75.3

75

70.5

70
65

70
65

60

242

20

500
1000
Q [US.gpm]

1500

1000

2000
Q [IM.gpm]

2500

75

75

70

79.5

78
70

3000

70
65

60

65
60

266

3500

2000

60

326

296

4000

3000
14
P [kW]

P [hp]
10
326

10
296
266
242

Free passage

500
1000
Q [US.gpm]

1500

2000

2500

3000

2
3500

4000

K42188--1

2 3/4 [70 mm]

Rated power P2 and mass moment of inertia J23)


Size

Rated power P2

700-330 / 10 8 U / X
700-330 / 17 8 U / X

23)

[hp]

[kW]

13
22

9.7
16.4

Mass moment
of inertia J
[kgm2]
0.54
0.57

These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan K

17

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Amacan K 800-370, n = 875 rpm
Characteristic curves to ISO 9906 / 2 / 2B. The characteristic
curves correspond to the effective motor speed.

0
55

200

Q [m3/h]

400

600

100

800

Q [l/s]

1000

200

300
15

Qmin
60

40

70

75

H [ft]

80
70

60

70

60

20

75

[%]

78

60
78

81

81.7

80

81

81

75

70

78

75

76.2

78

80

78.1
78
75

30

Q [US.gpm] 2000

1000

70

70

3000

Q [IM.gpm] 2000

70

75

290

1000

75

78

70

H [m]

80

75

10

310

340

4000
3000

5
370

5000

4000
20

P [hp]
370

P [kW]

20

340

10
6

290

1000 Q [US.gpm] 2000

3000

10

310

4000

5000
K43175--0

Free passage

3 3/8 [85 mm]

Rated power P2 and mass moment of inertia J24)


Size

Rated power P2

800-370 / 10 8 U / X
800-370 / 17 8 U / X
800-370 / 21 8 U / X
800-370 / 26 8 U / X

24)

18

[hp]

[kW]

13
22
25
38

9.7
16.4
18.7
28.3

Mass moment
of inertia J
[kgm2]
0.59
0.62
0.68
0.87

These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan K

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Amacan K 700-371, n = 875 rpm
Characteristic curves to ISO 9906 / 2 / 2B. The characteristic
curves correspond to the effective motor speed.

0
50

Q [m3/h]

200

400

600

100

40

800

Q [l/s]

1000

200

300

15

Qmin
60

10

70

30

60
70
60
60

75.9

60

H [ft]

75

70

24

70

70

70

278

1000 Q [US.gpm] 2000

1000

60

300

3000

Q [IM.gpm] 2000

70

75

72.9

60

75
75

75.8
69.5

10

H [m]

77 77.1
77

75

70

20

[%]

75

60

370

60
60

323

350

4000

5000

3000

4000
16

20

370

P [kW]

P [hp]
10

350

10
323
278

300

2
0

1000

Q [US.gpm] 2000

3000

4000

5000
K42189--1

Free passage

4 1/8 [105 mm]

Rated power P2 and mass moment of inertia J25)


Size

Rated power P2

700-371 / 10 8 U / X
700-371 / 17 8 U / X
700-371 / 21 8 U / X

25)

[hp]

[kW]

13
22
25

9.7
16.4
18.7

Mass moment
of inertia J
[kgm2]
0.64
0.67
0.73

These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan K

19

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Amacan K 800-400, n = 875 rpm
Characteristic curves to ISO 9906 / 2 / 2B. The characteristic
curves correspond to the effective motor speed.

0
60

500

1000

Q [m3/h]

200

1500
Q [l/s]

2000

400

Qmin

15
60
70

40
60

H [ft]

[%]
[%]

75

60

78

70
75

70

75

60
70

77.5

60

20

71.1
70

55

Q [US.gpm]

2000

4000

2000

Q [IM.gpm]

H [m]

75
78

70

75
70

300

78

79.7

73.8

70

10

80.3
78

70

70

377

330 358

6000
4000

75

408

8000
6000

40

408

40

P [kW]

P [hp]

377
358

20

330

20
300

10

Free passage

2000

Q [US.gpm] 4000

6000

8000

4 [100 mm]

Rated power P2 and mass moment of inertia J26)


Size

Rated power P2

800-400 / 21 8 U / X
800-400 / 26 8 U / X
800-400 / 35 8 U / X
800-400 / 50 8 UN / XN

26)

20

[hp]

[kW]

25
38
47
67

18.7
26.3
35
50

Mass moment
of inertia J
[kgm2]
0.93
1.12
1.22
1.41

These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan K

K43176--0

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Amacan K 800-401, n = 875 rpm
Characteristic curves to ISO 9906 / 2 / 2B. The characteristic
curves correspond to the effective motor speed.

0
50

500

100

1000

Q [m3/h]

Q [l/s]

200

1500
300

400

500
15

H [m]

40

Qmin
65

10

70

30

[%]

73

65

75

70

H [ft]

73
65

20

65

76
70

74.7
73

70

72.1

73.2
73

331

1000
2000
Q [US.gpm]

3000
2000

4000
Q [IM.gpm]

73

5000

5
70

70

70

70

10
4

75
73

350

6000

4000

393
371

7000

8000

6000
30

40
393

P [hp]

P [kW]
20

371
350

20
331

10
10

Free passage

1000

2000
Q [US.gpm]

3000

4000

5000

6000

7000

8000
K43178--0

5 5/16 [135 mm]

Rated power P2 and mass moment of inertia J27)


Size

Rated power P2

800-401 / 17 8 U / X
800-401 / 21 8 U / X
800-401 / 26 8 U / X
800-401 / 35 8 U / X

27)

[hp]

[kW]

22
25
38
47

16.4
18.7
26.3
35

Mass moment
of inertia J
[kgm2]
0.87
0.93
1.12
1.22

These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan K

21

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Amacan K 1000-420, n = 875 rpm
Characteristic curves to ISO 9906 / 2 / 2B. The characteristic
curves correspond to the effective motor speed.

0
80

500

Q [m3/h] 1000

200

1500
Q [l/s]

2000

400

600

20

Qmin

60

60

H [ft]

70

60

70

60

40

70

60

70

H [m]
75

[%]

77

75
75

77

78.5

10

77.8
76.7
75

20

75.2

75

77

77

70

10

90

376

2000 Q [US.gpm] 4000

2000

6000

Q [IM.gpm] 4000

75

75

75

416
395

8000

435

10000

6000

8000

60

80
P [hp]

435

P [kW]

60

416

40

395
376

40

2000

Q [US.gpm] 4000

6000

8000

10000
K43179--0

Free passage

4 [100 mm]

Rated power P2 and mass moment of inertia J28)


Size

Rated power P2

1000-420 / 50 8 UN / XN
1000-420 / 75 8 UN / XN

28)

22

[hp]

[kW]

67
100

50
74.6

Mass moment
of inertia J
[kgm2]
1.88
2.16

These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan K

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Amacan K 1000-500, n = 875 rpm
Characteristic curves to ISO 9906 / 2 / 2B. The characteristic
curves correspond to the effective motor speed.

0
110

1000

200

2000

Q [m3/h]

Q [l/s]

400

3000
600

800

1000

100

30

80

H [m]

Qmin
60

70

60

[%]

78
82

60

70

H [ft]
60

40

75

20

83.2

75

78

82
79.5

70

75

60
70

78

78
76.1

75
75
70

70

20

70

393

170

0
2000
Q [US.gpm]

4000

0 Q [IM.gpm] 2000

6000
4000

8000
6000

10000
8000

10

70

75

72.4

430

12000

460

14000

10000

508

16000

12000

150
508

P [hp]
460

100

100

P [kW]

430

50

393

50

Free passage

2000

4000
Q [US.gpm]

6000

8000

10000

12000

14000

16000
K43180--0

4 1/4 [110 mm]

Rated power P2 and mass moment of inertia J29)


Size

Rated power P2

1000-500 / 75 8 UN / XN
1000-500 / 90 8 UN / XN
1000-500 / 110 8 UN / XN
1000-500 / 130 8 UN / XN

29)

[hp]

[kW]

100
121
148
174

74.6
90.2
110.4
129.8

Mass moment
of inertia J
[kgm2]
4.06
5.10
5.37
5.67

These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan K

23

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Amacan K 1200-630, n = 875 rpm
Characteristic curves to ISO 9906 / 2 / 2B. The characteristic
curves correspond to the effective motor speed.

0
120

1000

Q [m3/h] 2000

3000

500

4000

Q [l/s]

5000

1000

1500

100

30

Qmin
60

80

60

H [m]
70
75

60

60

75

70

75

70

H [ft]

78

80

80.6
79.6
80
78.1
78
78
76.8

75

60

72.6

340

75
70

20
5

75
70

78

5000

10000

5000

15000

Q [IM.gpm] 10000

10

70

70

70

565

60

60

450

Q [US.gpm]

75

75

60

20

78

70

40

[%]

78

70

60

512 540
490

20000

25000

15000

20000

300
P [hp]

200

565

200

P [kW]

540
512
490

100

450

100
0

5000

Q [US.gpm] 10000

15000

20000

25000
K42193--1

Free passage

5 1/4 [133 mm]

Rated power P2 and mass moment of inertia J30)


Size

Rated power P2

1200-630 / 130 8 UN / XN
1200-630 / 150 8 UN / XN
1200-630 / 185 8 UN / XN
1200-630 / 220 8 UN / XN
1200-630 / 260 8 UN / XN

30)

24

[hp]

[kW]

174
200
250
295
350

129.8
149.1
186.4
220
261

Mass moment
of inertia J
[kgm2]
7.77
12.5
13.8
15.1
18.5

These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan K

Water Applications: Water Transport


Submersible Pump in Discharge Tube
n = 700 rpm
Amacan K 1000-500, n = 700 rpm
Characteristic curves to ISO 9906 / 2 / 2B. The characteristic
curves correspond to the effective motor speed.

500

Q [m3/h] 1000
200

1500

Q [l/s]

2000

400

2500
600

800

60

Qmin
60
70

[%]

75

40

80
82

60

70

H [ft]
60

82.5

75

80

78.8

70
75

60

20

10

82

70

75
75.3

75

75

70

71.6
70

70

393

90

0 Q [US.gpm] 2000
0

2000

4000

6000

Q [IM.gpm] 4000

H [m]

70

8000
6000

430

460

10000

508

12000

8000

10000
60

80

P [kW]

P [hp]

508

60

460

40

430

40
393

25

0 Q [US.gpm] 2000

4000

6000

8000

10000

20
12000
K42272--1

Free passage

4 1/4 [110 mm]

Rated power P2 and mass moment of inertia J31)


Size

Rated power P2

1000-500 / 40 10 UN/XN
1000-500 / 60 10 UN/XN
1000-500 / 75 10 UN/XN

31)

[hp]

[kW]

50
80
100

37.3
59.7
74.6

Mass moment
of inertia J
[kgm2]
4.87
5.05
5.32

These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan K

25

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Amacan K 1200-630, n = 700 rpm
Characteristic curves to ISO 9906 / 2 / 2B. The characteristic
curves correspond to the effective motor speed.

0
75

1000

200

Q [m3/h]

Q [l/s]

2000

400

3000

600

4000

800

1000

1200

20
60

Qmin

H [ft]

60
75
70

60

40

H [m]

70

60

60

[%]
[%]

78
75

70

75

70

78
79.9

75

60

78.8
77.3

70

76
71.8

20

75
70

10

78

78

70

60

170

450

2000
4000
Q [US.gpm]

6000

8000

5000

10000

12000

Q [IM.gpm]

10000

14000

70

70

70

60

75

75

75

60

512
490

16000

565
540

60

18000
15000

150
100

P [hp]

565

100

P [kW]

540
512

50

490
450

50
0

2000
4000
Q [US.gpm]

Free passage

6000

8000

10000

12000

14000

16000

5 1/4 [133 mm]

Rated power P2 and mass moment of inertia J32)


Size

Rated power P2

1200-630 / 60 10 UN / XN
1200-630 / 75 10 UN / XN
1200-630 / 90 10 UN / XN
1200-630 / 110 10 UN / XN
1200-630 / 150 10 UN / XN

32)

26

[hp]

[kW]

80
100
121
148
200

59.7
74.6
90.2
110.4
149.1

Mass moment
of inertia J
[kgm2]
7.15
7.42
7.71
13.2
14.9

These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan K

18000

K42194--1

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Dimensions
UG/XG motors (700-324 to 800-401) [inch]

A
A

h2

h1

h4

DB

X
h3

X
d2

d1

45

2 3/8

/16

45

13

/16

D
Di

d7
d20
Dimensions of pump set and seat ring
Dimensions [inch]
Pump size
700-324
700-324
700-330
700-330
700-330
700-330
700-371

33)
34)

Motor size
10
17
20
26
10
17
20

Number
of poles
8
8
6
6
8
8
6

Pump
h1

h2

h3

h4

45 1/4
45 1/4
45 1/4
44 5/16
45 1/4
45 1/4
45 1/4

38 3/4
38 3/4
38 3/4
37 13/16
38 3/4
38 3/4
38 3/4

5 15/16
5 15/16
5 15/16
5 15/16
5 15/16
5 15/16
5 15/16

38 3/4
38 3/4
38 3/4
37 13/16
38 3/4
38 3/4
38 3/4

Seat ring

DB

d1

d2

/16
9
/16
9
/16
9
/16
9
/16
9
/16
9
/16

26 3/8
26 3/8
26 3/8
26 3/8
26 3/8
26 3/8
26 3/8

21 7/8
21 7/8
21 7/8
21 7/8
21 7/8
21 7/8
21 7/8

8 1/16
8 1/16
8 1/16
8 1/16
8 1/16
8 1/16
8 1/16

[lbs]33)
871
904
926
970
882
915
915

d7

d20

Di

22 7/16
22 7/16
22 7/16
22 7/16
22 7/16
22 7/16
22 7/16

27 3/16
27 3/16
27 3/16
27 3/16
27 3/16
27 3/16
27 3/16

27 3/8
27 3/8
27 3/8
27 3/8
27 3/8
27 3/8
27 3/8

D34)
28
28
28
28
28
28
28

Pump set with 33 ft [10 m] power cable (460 V) and 16.4 ft [5 m] support rope
D for recommended wall thickness of the discharge tube (see dimension s1 in the General Arrangement Drawings)

Amacan K

27

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Pump size
700-371
700-371
700-371
700-371
800-330
800-330
800-370
800-370
800-370
800-370
800-370
800-370
800-370
800-370
800-371
800-371
800-371
800-400
800-400
800-400
800-401
800-401
800-401
800-401
800-401
800-401

33)
34)

28

Motor size
26
10
17
21
32
40
26
32
40
50
10
17
21
26
32
40
50
21
26
35
40
50
17
21
26
35

Number
of poles
6
8
8
8
6
6
6
6
6
6
8
8
8
8
6
6
6
8
8
8
6
6
8
8
8
8

Pump

Seat ring

h1

h2

h3

h4

DB

d1

d2

44 5/16
45 1/4
45 1/4
44 5/16
55 1/2
55 1/2
42 1/2
53 15/16
53 15/16
53 15/16
43 1/2
43 1/2
42 1/2
53 15/16
55 1/2
55 1/2
55 1/2
46 1/4
57 11/16
57 11/16
57 11/16
57 11/16
47 1/4
46 1/4
57 11/16
57 11/16

37 13/16
38 3/4
38 3/4
37 13/16
40 3/4
40 3/4
36 1/4
39 3/16
39 3/16
39 3/16
37 3/16
37 3/16
36 1/4
39 3/16
40 3/4
40 3/4
40 3/4
39 15/16
42 15/16
42 15/16
42 15/16
42 15/16
40 15/16
39 15/16
42 15/16
42 15/16

5 15/16
5 15/16
5 15/16
5 15/16
5 15/16
5 15/16
5 13/16
5 13/16
5 13/16
5 13/16
5 13/16
5 13/16
5 13/16
5 13/16
5 15/16
5 15/16
5 15/16
7 3/16
7 3/16
7 3/16
7 3/16
7 3/16
7 3/16
7 3/16
7 3/16
7 3/16

37 13/16
38 3/4
38 3/4
37 13/16
48 1/16
48 1/16
36 1/4
46 7/16
46 7/16
46 7/16
37 3/16
37 3/16
36 1/4
46 7/16
48 1/16
48 1/16
48 1/16
38 9/16
48 13/16
48 13/16
48 13/16
48 13/16
39 9/16
38 9/16
48 13/16
48 13/16

/16
9
/16
9
/16
9
/16
1 9/16
1 9/16
9
/16
1 9/16
1 9/16
1 9/16
9
/16
9
/16
9
/16
1 9/16
9
/16
9
/16
9
/16
9
/16
1 9/16
1 9/16
1 9/16
1 9/16
9
/16
9
/16
1 9/16
1 9/16

26 3/8
26 3/8
26 3/8
26 3/8
26 3/8
26 3/8
29 15/16
29 15/16
29 15/16
29 15/16
29 15/16
29 15/16
29 15/16
29 15/16
26 3/8
26 3/8
26 3/8
30 5/16
30 5/16
30 5/16
30 5/16
30 5/16
30 5/16
30 5/16
30 5/16
30 5/16

21 7/8
21 7/8
21 7/8
21 7/8
21 7/8
21 7/8
25 3/16
25 3/16
25 3/16
25 3/16
25 3/16
25 3/16
25 3/16
25 3/16
21 7/8
21 7/8
21 7/8
25 3/16
25 3/16
25 3/16
25 3/16
25 3/16
25 3/16
25 3/16
25 3/16
25 3/16

8 1/16
8 1/16
8 1/16
8 1/16
13 3/8
13 3/8
8 1/16
13 3/8
13 3/8
13 3/8
8 1/16
8 1/16
8 1/16
13 3/8
13 3/8
13 3/8
13 3/8
8 1/16
13 3/8
13 3/8
13 3/8
13 3/8
8 1/16
8 1/16
13 3/8
13 3/8

[lbs]33)
959
882
915
959
1290
1345
1025
1345
1400
1466
948
981
1025
1389
1279
1334
1400
1268
1631
1698
1598
1664
1179
1224
1587
1653

d7

d20

Di

22 7/16
22 7/16
22 7/16
22 7/16
22 7/16
22 7/16
25 13/16
25 13/16
25 13/16
25 13/16
25 13/16
25 13/16
25 13/16
25 13/16
22 7/16
22 7/16
22 7/16
25 13/16
25 13/16
25 13/16
25 13/16
25 13/16
25 13/16
25 13/16
25 13/16
25 13/16

27 3/16
27 3/16
27 3/16
27 3/16
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4
31 1/4

27 3/8
27 3/8
27 3/8
27 3/8
31 3/8
31 3/8
31 3/8
31 3/8
31 3/8
31 3/8
31 3/8
31 3/8
31 3/8
31 3/8
31 3/8
31 3/8
31 1/8
31 3/8
31 3/8
31 3/8
31 3/8
31 3/8
31 3/8
31 3/8
31 3/8
31 3/8

Pump set with 33 ft [10 m] power cable (460 V) and 16.4 ft [5 m] support rope
D for recommended wall thickness of the discharge tube (see dimension s1 in the General Arrangement Drawings)

Amacan K

D34)
28
28
28
28
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32

Water Applications: Water Transport


Submersible Pump in Discharge Tube
UNG/XNG motors (800-370 to 1200-630) [inch]

DB

h2

h1

h4

X
h3

45

d2

d1
D

2 3/8

/16

45

13

/16

Di

d7
d20
Dimensions of pump set and seat ring

Amacan K

29

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Dimensions [inch]
Pump size
800-370
800-400
800-401
800-401
1000-420
1000-420
1000-500
1000-500
1000-500
1000-500
1000-500
1000-500
1000-500
1200-630
1200-630
1200-630
1200-630
1200-630
1200-630
1200-630
1200-630
1200-630
1200-630

35)
36)

30

Motor size
60
50
60
80
50
75
75
90
110
130
40
60
75
130
150
185
220
260
60
75
90
110
150

Number
of poles
6
8
6
6
8
8
8
8
8
8
10
10
10
8
8
8
8
8
10
10
10
10
10

Pump

Seat ring

h1

h2

h3

h4

DB

d1

d2

[lbs]35)

d7

d20

Di

83 1/4
87
87
94 7/8
90 15/16
98 13/16
99
103 9/16
103 9/16
103 9/16
103 9/16
103 9/16
103 9/16
105 11/16
115 3/4
115 3/4
115 3/4
126 3/16
105 11/16
105 11/16
105 11/16
115 3/4
115 3/4

56 1/8
59 13/16
59 13/16
67 11/16
63 3/4
71 5/8
71 7/8
76 3/8
76 3/8
76 3/8
76 3/8
76 3/8
76 3/8
78 9/16
92 1/8
92 1/8
92 1/8
98 5/8
78 9/16
78 9/16
78 9/16
92 1/8
92 1/8

5 13/16
7 3/16
7 3/16
7 3/16
8 1/4
8 1/4
8 1/16
8 1/16
8 1/16
8 1/16
8 1/16
8 1/16
8 1/16
10 9/16
10 9/16
10 9/16
10 9/16
10 9/16
10 9/16
10 9/16
10 9/16
10 9/16
10 9/16

75 13/16
78 1/8
78 1/8
86
81 1/8
89
89 3/8
93 7/8
93 7/8
93 7/8
93 7/8
93 7/8
93 7/8
93 11/16
103 1/8
103 1/8
103 1/8
113 3/16
93 11/16
93 11/16
93 11/16
103 1/8
103 1/8

1 9/16
1 9/16
1 9/16
1 9/16
1 9/16
1 9/16
1 9/16
1 9/16
1 9/16
1 9/16
1 9/16
1 9/16
1 9/16
1 9/16
1 15/16
1 15/16
1 15/16
2 3/8
1 9/16
1 9/16
1 9/16
1 15/16
1 15/16

29 15/16
30 5/16
30 5/16
30 5/16
38 3/16
38 3/16
38 3/16
38 3/16
38 3/16
38 3/16
38 3/16
38 3/16
38 3/16
44 7/8
44 7/8
44 7/8
44 7/8
44 7/8
44 7/8
44 7/8
44 7/8
44 7/8
44 7/8

25 3/16
25 3/16
25 3/16
25 3/16
33 1/16
33 1/16
32 5/16
32 5/16
32 5/16
32 5/16
32 5/16
32 5/16
32 5/16
37 13/16
37 13/16
37 13/16
37 13/16
37 13/16
37 13/16
37 13/16
37 13/16
37 13/16
37 13/16

2061
2293
2260
2458
2811
3164
3208
3847
3979
4090
3748
3858
3990
4652
6019
6393
6878
8267
4321
4475
4652
5908
6217

25 13/16
25 13/16
25 13/16
25 13/16
33 11/16
33 11/16
33 11/16
33 11/16
33 11/16
33 11/16
33 11/16
33 11/16
33 11/16
39 15/16
39 15/16
39 15/16
39 15/16
39 15/16
39 15/16
39 15/16
39 15/16
39 15/16
39 15/16

31 1/4
31 1/4
31 1/4
31 1/4
39 1/16
39 1/16
39 1/16
39 1/16
39 1/16
39 1/16
39 1/16
39 1/16
39 1/16
46 15/16
46 15/16
46 15/16
46 15/16
46 15/16
46 15/16
46 15/16
46 15/16
46 15/16
46 15/16

31 3/8
31 3/8
31 3/8
31 3/8
39 3/16
39 3/16
39 3/16
39 3/16
39 3/16
39 3/16
39 3/16
39 3/16
39 3/16
47 1/16
47 1/16
47 1/16
47 1/16
47 1/16
47 1/16
47 1/16
47 1/16
47 1/16
47 1/16

Pump set with 33 ft [10 m] power cable (460 V) and 16.4 ft [5 m] support rope
D for recommended wall thickness of the discharge tube (see dimension s1 in the General Arrangement Drawings)

Amacan K

D36)
32
32
32
32
40
40
40
40
40
40
40
40
40
48 1/16
48 1/16
48 1/16
48 1/16
48 1/16
48 1/16
48 1/16
48 1/16
48 1/16
48 1/16

Water Applications: Water Transport


Submersible Pump in Discharge Tube
UG/XG motors (700-324 to 800-401) [mm]

A
A

h2

h1

h4

DB

X
h3

X
d2

d1

45

60

45

20

D
Di

d7
d20
Dimensions of pump set and seat ring
Dimensions [mm]
Pump size
700-324
700-324
700-330
700-330
700-330
700-330
700-371
700-371
700-371
700-371
700-371

37)
38)

Motor size
10
17
20
26
10
17
20
26
10
17
21

Number
of poles
8
8
6
6
8
8
6
6
8
8
8

Pump

Seat ring

h1

h2

h3

h4

DB

d1

d2

[kg]37)

d7

d20

Di

1150
1150
1150
1125
1150
1150
1150
1125
1150
1150
1125

985
985
985
960
985
985
985
960
985
985
960

151
151
151
151
151
151
151
151
151
151
151

985
985
985
960
985
985
985
960
985
985
960

15
15
15
15
15
15
15
15
15
15
15

670
670
670
670
670
670
670
670
670
670
670

556
556
556
556
556
556
556
556
556
556
556

205
205
205
205
205
205
205
205
205
205
205

395
410
420
440
400
415
415
435
400
415
435

570
570
570
570
570
570
570
570
570
570
570

691
691
691
691
691
691
691
691
691
691
691

695
695
695
695
695
695
695
695
695
695
695

D38)
711
711
711
711
711
711
711
711
711
711
711

Pump set with 10-meter power cable (460 V) and 5-meter support rope
D for recommended wall thickness of the discharge tube (see dimension s1 in the General Arrangement Drawings)

Amacan K

31

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Pump size
800-330
800-330
800-370
800-370
800-370
800-370
800-370
800-370
800-370
800-370
800-371
800-371
800-371
800-400
800-400
800-400
800-401
800-401
800-401
800-401
800-401
800-401

37)
38)

32

Motor size
32
40
26
32
40
50
10
17
21
26
32
40
50
21
26
35
40
50
17
21
26
35

Number
of poles
6
6
6
6
6
6
8
8
8
8
6
6
6
8
8
8
6
6
8
8
8
8

Pump

Seat ring

h1

h2

h3

h4

DB

d1

d2

1410
1410
1080
1370
1370
1370
1105
1105
1080
1370
1410
1410
1410
1175
1465
1465
1465
1465
1200
1175
1465
1465

1035
1035
920
995
995
995
945
945
920
995
1035
1035
1035
1015
1090
1090
1090
1090
1040
1015
1090
1090

151
151
148
148
148
148
148
148
148
148
151
151
151
183
183
183
183
183
183
183
183
183

1220
1220
920
1180
1180
1180
945
945
920
1180
1220
1220
1220
980
1240
1240
1240
1240
1005
980
1240
1240

40
40
15
40
40
40
15
15
15
40
40
40
40
15
40
40
40
40
15
15
40
40

670
670
760
760
760
760
760
760
760
760
670
670
670
770
770
770
770
770
770
770
770
770

556
556
640
640
640
640
640
640
640
640
556
556
556
640
640
640
640
640
640
640
640
640

340
340
205
340
340
340
205
205
205
340
340
340
340
205
340
340
340
340
205
205
340
340

[kg]37)
585
610
465
610
635
665
430
445
465
630
580
605
635
575
740
770
725
755
535
555
720
750

d7

d20

Di

570
570
656
656
656
656
656
656
656
656
570
570
570
656
656
656
656
656
656
656
656
656

793
793
793
793
793
793
793
793
793
793
793
793
793
793
793
793
793
793
793
793
793
793

797
797
797
797
797
797
797
797
797
797
797
797
797
797
797
797
797
797
797
797
797
797

Pump set with 10-meter power cable (460 V) and 5-meter support rope
D for recommended wall thickness of the discharge tube (see dimension s1 in the General Arrangement Drawings)

Amacan K

D38)
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813

Water Applications: Water Transport


Submersible Pump in Discharge Tube
UNG/XNG motors (800-370 to 1200-630) [mm]

DB

h2

h1

h4

X
h3

45

d2

d1
D

20

45

60

Di

d7
d20
Dimensions of pump set and seat ring

Amacan K

33

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Dimensions [inch]
Pump size
800-370
800-400
1000-420
1000-420
1000-500
1000-500
1000-500
1000-500
1000-500
1000-500
1000-500
1200-630
1200-630
1200-630
1200-630
1200-630
1200-630
1200-630
1200-630
1200-630
1200-630

39)
40)

34

Motor size
60
50
50
75
75
90
110
130
40
60
75
130
150
185
220
260
60
75
90
110
150

Number
of poles
6
8
8
8
8
8
8
8
10
10
10
8
8
8
8
8
10
10
10
10
10

Pump

Seat ring

h1

h2

h3

h4

DB

d1

d2

[kg]39)

d7

d20

Di

2115
2210
2310
2510
2515
2630
2630
2630
2630
2630
2630
2685
2940
2940
2940
3205
2685
2685
2685
2940
2940

1425
1520
1620
1820
1825
1940
1940
1940
1940
1940
1940
1995
2340
2340
2340
2505
1995
1995
1995
2340
2340

148
183
209
209
205
205
205
205
205
205
205
268
268
268
268
268
268
268
268
268
268

1925
1985
2060
2260
2270
2385
2385
2385
2385
2385
2385
2380
2620
2620
2620
2875
2380
2380
2380
2620
2620

40
40
40
40
40
40
40
40
40
40
40
40
50
50
50
60
40
40
40
50
50

760
770
970
970
970
970
970
970
970
970
970
1140
1140
1140
1140
1140
1140
1140
1140
1140
1140

640
640
840
840
820
820
820
820
820
820
820
960
960
960
960
960
960
960
960
960
960

935
1040
1275
1435
1455
1745
1805
1855
1700
1750
1810
2110
2730
2900
3120
3750
1960
2030
2110
2680
2820

656
656
856
856
856
856
856
856
856
856
856
1015
1015
1015
1015
1015
1015
1015
1015
1015
1015

793
793
992
992
992
992
992
992
992
992
992
1192
1192
1192
1192
1192
1192
1192
1192
1192
1192

797
797
996
996
996
996
996
996
996
996
996
1196
1196
1196
1196
1196
1196
1196
1196
1196
1196

Pump set with 10-meter power cable (460 V) and 5-meter support rope
D for recommended wall thickness of the discharge tube (see dimension s1 in the General Arrangement Drawings)

Amacan K

D40)
813
813
1016
1016
1016
1016
1016
1016
1016
1016
1016
1220
1220
1220
1220
1220
1220
1220
1220
1220
1220

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Types of installation
Overview of installation types

BU discharge tube
overflow design

DU discharge tube
with above-floor discharge nozzle

CU discharge tube
with underfloor discharge

Scope of supply
Depending on the model, the following items are included in
the scope of supply:
Basic design: pump set complete with power cable 32.8 ft
[10 m]

- Support spacer
- Shackle
- Cable clamps
Cable support sleeves
Discharge tube in various designs (steel or GFK)

O-ring
Back-up name plate
Accessories (optional):
Support rope
Accessories for installing the cable guide
- Spacer
- Turnbuckle

Amacan K

35

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Accessories
Pump with support rope and turnbuckle in the discharge tube
For large installation depths
(with support spacer)

59-8
59-17.2

59-24
720
59-47*

59-17.1

59-7

UG 1073883zdk

*= The number of (intermediate) lifting rings depends on the lifting height of the hoisting tackle and on the building structure.
(Intermediate lifting rings are supplied as an option).

List of components
Part No.
59-8
59-17.2
59-47
59-24
720
59-17.1

Description
Turnbuckle
Shackle
(Intermediate) lifting ring(s)
Rope, low rotation design
Spacer
Shackle

59-7

Support spacer

36

Amacan K

Material
Stainless steel
Stainless steel
Stainless steel
Stainless steel
EPDM
Galvanized steel (stainless
steel optional)
GFRP

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Cross-section of cable support
A-A

1
6

3
5

4
OW 380 091-00

List of components
Part No.
1
2
3

Description
Cable clamp (approximately every 400 mm)
Control cable
Power cable

Part No.
4
5
6

Description
Support rope 59-24
Spacer
Clamp cover

Discharge tube cover with cable gland


Design: with welding sleeve
A-A

A
A
2

OW 380 836-00

List of components
Part No.
1

Description
Discharge tube cover41)

Part No.
4

2
3

Cover
Welding sleeve

5
6

41)

Description
Threaded bush with cable entry to DIN 22419 with strain
relief and protection against kinking and twisting
Eyeplate for fastening the cable support (support rope)
Gasket, e.g. fabric-reinforced rubber

Discharge tube cover also available in split design

Amacan K

37

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Design variant: with transit frame (up to 1 bar)
View X

2
3

A-A

A -- A

OW 380 861-00

List of components
Part no.
1
2
3
4
5
6
7
8

42)

38

Description
Discharge tube cover42)
Transit frame (cable gland)
Packing and insert blocks
Cover segment with cable gland
Sealing of split cover with closed cell profile gasket
Gap cover
Support brackets for cover segment with cable glands
Gasket (e.g. rubber with fabric reinforcement)

Discharge tube cover also available in single-piece design.

Amacan K

Water Applications: Water Transport


Submersible Pump in Discharge Tube
General assembly drawings with list of components
Amacan K 700 - 324 ... 800 - 401, motor version: UG/XG
Amacan K 700 - 324
Amacan K 700 - 330
Amacan K 700 - 371
Amacan K 800 - 370
Amacan K 800 - 400
Amacan K 800 - 401

571

811

818

412

834

330

433

433
230

412

412
101
163
502
UG 1294437

List of components
Part No.
101
163
230
330
412
433

Description
Pump casing
Discharge cover
Impeller
Bearing bracket
O-ring
Mechanical seal

Part No.
502
571
811
818
834
-

Description
Casing wear ring
Bail
Motor housing
Rotor
Cable gland
-

Amacan K

39

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Amacan K 800 - 330 ... 800 - 401, motor version: UG/XG
Amacan K 800 - 330
Amacan K 800 - 370
Amacan K 800 - 371
Amacan K 800 - 400
Amacan K 800 - 401

571
330.02

412

834
811

818

412
330
412
433
412
412
433
163
230

412
101
502

List of components
Part No.
101
163
230
330
412
433

40

Description
Pump casing
Discharge cover
Impeller
Bearing bracket
O-ring
Mechanical seal

Amacan K

Part No.
502
571
811
818
834
-

Description
Casing wear ring
Bail
Motor housing
Rotor
Cable gland
-

Water Applications: Water Transport


Submersible Pump in Discharge Tube
Amacan K 800 - 370 ... 1200 - 630, motor version: UNG/XNG
Amacan K 800 - 370
Amacan K 800 - 400
Amacan K 800 - 401
Amacan K 1000 - 420
Amacan K 1000 - 500
Amacan K 1200 - 630
571

834
812

412
811
330

818

412
412

433
350
412
433
163
230

502

412
412

101

List of components
Part No.
101
163
230
330
350
412
433

Description
Pump casing
Discharge cover
Impeller
Bearing bracket
Bearing housing
O-ring
Mechanical seal

Part No.
502
571
811
812
818
834
-

Description
Casing wear ring
Bail
Motor housing
Motor housing cover
Rotor
Cable gland
-

Amacan K

41

05.03.2014
1579.56/03-US

KSB, Inc.
4415 Sarellen Road Richmond, VA 23231
Phone: (804) 222-1818 Fax: (804) 226-6961 www.ksbusa.com
KSB PUMPS Inc.
5885 Kennedy Road Mississauga Ontario L 4Z 2G3
Phone: (905) 568-9200 Fax: (905) 568-3740 www.ksb.ca

You might also like