Standard 19" rack panel, 3" high
Dual redundant power supplies
Worldwide AC input capability
Monitors converter bias currents to detect
faults
Manual or automatic operation
Manual override switch control knob on
rear panel
Options
Offline I/O
Remote panel
Block Diagram
10111 C
Operating Modes
Automatic Mode
In Automatic mode, if a failure is detected in the on-line converter, the
standby converter is switched on-line;
switchover is accomplished in 100 milliseconds. The unit will not switch to a
defective converter.
Manual Mode
The converters can also be manually
switched from the front panel or remotely. In Manual mode, automatic
switching will not occur upon fault detection, although the monitor and alarm
circuits still function.
MODEL: BRK-1101
CONTROL
SELECT
UNIT 2
UNIT 1
UNIT 2
REMOTE
MANUAL
ALARMS
PS1
PS2
AUTO
LAMP
TEST
LOCAL
RF OUTPUTS
J6, J7 TYPE BNC FEMALE
REAR PANEL
J1
J5
J3
J4
10111 C
J6
UNIT 2
OUT
STBY
IN
STBY
OUT
J8
J2
UNIT 1
IN
J7
RF INPUTS
J5, J8, TYPE N FEMALE
System Specifications *
Parameter
Notes
Configuration
Input Frequency Range
BDC-12000F
BDC-12000B
BDC-12000J
BDC-12000C
Gain Flatness
BDC-12000F
BDC-12000B
BDC-12000J
BDC-12000C
BDC-12000x, Standard
BDC-12000x w/ Option 2
Full band
Noise Figure
Power Output
At +23 C
At 1 dB compression
Output, OIP3
BDC-12000F
BDC-12000B
BDC-12000J
BDC-12000C
Over temperature
@ 100 Hz offset
@ 1 kHz offset
@ 10 kHz offset
@ 100 kHz offset
VSWR
System Gain
Connectors
Operating Modes
Alarm Method
Window Width
Jumper selectable
Remote I/O
Form C contacts
Control inputs
Power Requirements
Voltage
Frequency
Power
Size
Temperature Range
Operating
BRK-1101 Series
Min
Nom/Typ
Max
+8
+18
2000
1750
2000
1750
12
22
1.0
14
+10
1.5
16
+20
9.75
9.95
10.75
11.25
12
Units
GHz
GHz
GHz
GHz
MHz
MHz
MHz
MHz
dB
dB
dB
dB
dBm
dBm
GHz
GHz
GHz
GHz
20
-60
-70
-80
-90
1.20
1.25
1.5
2.0
Type N Female
Type BNC Female (75 ohms)
37-pin D Male (2 in parallel)
kHz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
:1
:1
Manual or Automatic
BDC phase lock/bias current.
Alarm is generated if current goes
outside of current window.
5 mA to 25 mA in 5 mA steps
100 Vdc/250 mA
Contact closure to ground;
withstand 15 V, sink 10 mA
-13%
100/120/220/240
+10%
47
63
30
19 x 3.47 x 22
483 x 88.1 x 559
0
+50
Vac
Hz
W
inches
mm
C
* System specifications depend on choice of BDC and various options. Specifications shown are for VertexRSI BDC-12000 series.
When there is only one value on a line, this column is a nominal value. Otherwise it is a typical value. Typical values are intended to
illustrate typical performance, but are not guaranteed.
BRK-1101Assigned by factory
at time of order.
BDC Model Number:
BDC-12000
(See BDC-12000 Series specification sheet.)
Option 2:
Option 5:
Offline I/O
Remote panel