You are on page 1of 6

Alarm type

Common
Common
Common
Common
Common
Common
Common
Common
Common
Common
Common
Common
Common
Common
Common
Common
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8

UNIT_TYPE
UMP
UMP
UMP
UMP
UMP
UMP
UMP
GPSR
GPSR
GPSR
GPSR
GPSR
GPSR
GPSR
SYS
SYS
ECP
ECP
ECP
ECP
ECP
ECP
ECP
ECP
ECP
ECP
ECP
ECP
ECP
ECP
ECP
RRH
RRH
RRH
RRH
RRH
RRH
RRH
RRH
RRH
RRH
RRH
RRH
RRH

TYPE
Common
Common
Common
Common
Common
Common
Common
Common
Common
Common
Common
Common
Common
Common
Common
Common
ECP
ECP
ECP
ECP
ECP
ECP
ECP
ECP
ECP
ECP
ECP
ECP
ECP
ECP
ECP
RET
RET
RET
RET
RET
RET
RET
RRH
RRH
RRH
RRH
RRH
RRH

UMP-PROCESS_DOWN
UMP-CPU_TEMPERATURE_HIGH
UMP-DISK_FULL
UMP-MEMORY_FULL
UMP-OVERLOAD
UMP-CLOCK_FAIL
UMP-MEMORY_FAIL
GPSR-TOD_MSG_MISSED
GPSR-ANTENNA_FAIL
GPSR-HOLDOVER_24H
GPSR-LOCKING_FAIL
GPSR-FUNCTION_FAIL
GPSR-FREQUENCY_HOLDOVER_EXCEED
GPSR-GPS_CLOCK_PHASE_ABNORMAL
SYS-FAN_FAIL
SYS-MME_COMMUNICATION_FAIL
ECP-BOARD_DELETION
ECP-DSP_RESTART
ECP-PROCESS_DOWN
ECP-DISK_FULL
ECP-MEMORY_FULL
ECP-OVERLOAD
ECP-CLOCK_FAIL
ECP-POWER_FAIL
ECP-FUNCTION_FAIL
ECP-DSP_FAIL
ECP-CPRI_FAIL
ECP-OPTIC_TRANSCEIVER_RX_LOS
ECP-OPTIC_TRANSCEIVER_TX_FAULT
ECP-COMMUNICATION_FAIL
ECP-SFN_FAIL
RRH-RET_MOTOR_JAM
RRH-RET_ACTUATOR_JAM
RRH-RET_NOT_CALIBRATED
RRH-RET_NOT_CONFIGURED
RRH-RET_HW_ERROR
RRH-RET_ACTUATOR_INTERFERENCE
RRH-ALD_COMMUNICATION_FAIL
RRH-TEMPERATURE_HIGH
RRH-CLOCK_FAIL
RRH-COMMUNICATION_FAIL
RRH-DC_INPUT_FAIL
RRH-DISABLED
RRH-LNA_FAIL

2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
2.3 or 1.8
All
All
exception
exception
exception
exception
exception
exception
exception
exception
exception
exception

RRH
RRH
RRH
RRH
RRH
B/H
B/H
UMP
UMP
UMP
ECP
SYS
SYS
SYS
SYS
SYS
SYS

RRH
RRH
RRH
RRH
RRH
B/H
B/H

RRH-LOW_GAIN
RRH-OVER_POWER
RRH-VSWR_FAIL
RRH-DIGITAL_INPUT_LOW
RRH-HW_TYPE_MISMATCH
B/H Down
B/H Down
UMP-PACKET_ERROR
UMP-PORT_DOWN
UMP-ETHERNET_HALF_DUPLEX_DETECTED
ECP-PACKET_ERROR
SYS-UDA
SYS-NTP_UPDATE_ERROR
SYS-SERVICE_OFF
SYS-SLEEPING_CELL_DETECTION
SYS-IND_MME_COMMUNICATION_FAIL
SYS-MCE_COMMUNICATION_FAIL

ALARM_CODE
2100102
2100217
2100300
2100301
2100302
2100351
2100370
2180001
2180350
2180360
2180361
2180368
2180424
2180624
2199209
2199600
2116366
2116100
2116102
2116300
2116301
2116302
2116351
2116367
2116368
2116372
2116376
2116378
2116379
2116381
2116607
2149338
2149339
2149340
2149341
2149342
2149343
2149630
2149216
2149351
2149381
2149384
2149385
2149388

2149389
2149391
2149392
2149408
2149649
2006
2007
2100305
2100380
2100439
2116305
2199202
2199365
2199460
2199602
2199605
2199629

INFO
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When
When

process is deactivated.
the CPU temperature exceeds the threshold level.
disk usage rate exceeds the threshold level.[95/95,90/90,85/85]
memory usage rate exceeds the threshold level.[97/97,96/96,95/95]
CPU load exceeds the threshold level.[95/95,90/90,85/85]
the clock used within the board is not normal.
the kernel reaches the code related to memory operation error.
UMP cannot receive TOD message.
the antenna cable is not connected.
occurs after 24 hours since the shift to holdover status is made.
the normal GPS satellite signal cannot be received.
initialization due to GPSR restart or GPSR modulefailure has occurred.
Frequency holdover of GPS (FDD only) exceeds hold over time.
clock phase of GPS is drifted abnormaly.
FAN is not operating normally.
eNB cannot receive SCTP HeartBeat response from all MMEs.
the board is dismounted.
DSP restarts by reset.
process is deactivated.
disk usage rate exceeds the threshold level.[95/95,90/90,85/85]
memory usage rate exceeds the threshold level.[97/97,96/96,95/95]
CPU load exceeds the threshold level.[95/95,90/90,85/85]
the clock used within the board is not normal.
the power used within the board is unstable or not normal.
board is abnormal or loading is not completed.
the UMP cannot receive the Keep-Alive response from the DSP. When any of Core, Modem, and F
the CPRI LOS(Loss of Signal) or CPRI LOF(Loss of Frame) is occurs.
optic cable open or optical signal strength decreases.
power monitoring result of laser diode is abnormal.
UMP can not receive Keep-Alive response from ECP.
the measured SFN does not increase or decrease normally.
motor cannot move.
actuator jam has been detected.
the device has not completed a calibration operation or calibration has been lost
actuator configuration data is missing
any hardware error which cannot be classified is occurred
an actuator movement outside the control of the RET unit has been detected.
the UMP cannot receive Keep-Alive response from the ALD.
the temperature of RRH exceeds the threshold level.
the clock used within the RRH is not normal.
UMP can not receive keep-alive response from RRH.
the voltage of RRH is not normal range.
the state of RRH is disabled.
LNA Fail Condition is continued.

When
When
When
When
When

the gain is below the threshold level.


digital input power level is above than threshold level or RF power is above than threshold level
return loss of ANT port is below the threshold level.
the input IQ signal level is below the threshold value.
expanded HW Type of connected RRH is mismatching.

When
When
When
When
When
When
When
When
When
When

error packets rate exceeds the threshold level.


the link down failure of backhaul port occurs.
the backhaul port status is up and duplex mode is half duplex.
error packets rate exceeds the threshold level.
the UDA fault is occurs.
NTP server setting is not correct or the system time update is failed due to the connection fail w
all Cells of eNB are disabled.
the response from the cell has not arrived during a certain period of time in diagnosis call proce
eNB cannot receive SCTP HeartBeat response from specific MME.
eNB cannot receive SCTP HeartBeat response from Equipped specific MCE.