Manson

DC - DC CONVERTER
SDC - 5200 Series
New Generation Non-Isolated Step Down Converter

Manson

LEAD ACID BATTERY CHARGER


HBC - 1305 / 1310
24V Advanced Multi-Stage Battery Charger with MCU

Description
This new generation of SDC- 5200 series of voltage reducers offer regulated
13.8 V DC power from 20-30VDC source such as Land Rovers, commercial
vehicles, recreation vehicles, farming equipment and other diesel power
vehicles.
The very compact, lightweight and no vent hole casing construction is
possible because of the highly efficient, switch mode design with surface
mount devices.
Low heat output and low standby current take out the need for an external
power on-off switch.
The plastic clip-on mounting system makes the installation easy even in
awkward to reach spot. The unit is tamper and dust proof because of no vent
holes and no external fuse construction. The PCB component layout is
designed and built for vibration loosening resistant, and with moisture proof
coating making it ideal for off-road and harsh environments.
The advanced switching mode circuit design results a cool, silent, no
humming and no high frequency noise operation. Electronic safeguards and
fail-safe feature such as OVP ensure good protection to expensive connected
equipments even when there is a fault in the unit.
The 13.8VDC output can be used as a source for float charge for 12V auxiliary
battery.
Typical applications for this new generation of DC-DC converters are:
Radio communications, car entertainment such as DVD player, printers, on
board computers, security system, GPS, auxiliary lights, spot lights, charging
of 12V auxiliary battery, and etc.

Features

Slim, compact and light construction due to high efficiency & low heat
output.
Dust and tamper proof due to extruded aluminum casing of no vent hole
& no external fuse.
Reliable clip-on mounting bracket construction for easy installation even
in hard to get to spot.
Vibration loosening resistant & coated PCB assembly, ideal for off road
vehicles environment.
Advanced switching mode design & SMT components for high efficiency
& cool operation.
Low standby current takes out the need for an external on-off switch.
Over Voltage Protection against excessive output voltage in case of
wrong installation or fault.
Auto-reset loss of earth protection.
Auto-reset over power protection.
Auto-reset reverse polarity protection.
Separate LED indicator for operation and fault status.
Meet e-Mark and CE standards.

Specifications

Specifications
Model
AC Input Voltage 100 - 240VAC, 50/60Hz~
AC Input Current at Full Load (at 230 / 100 AC)
Output (Charge) Voltage Selections
WET
LiFePO4
AGM
GEL 1
GEL 2
CALCIUM
User Define 1
User Define 2
Equalization
Maximum Output Charging Current (continuous)
Soft Start Bulk Charge
Battery Voltage to Trigger (cut-in) Soft Start Bulk Charge Mode
Soft Start Bulk Charge Current Level (current limit)
Ripple & Noise (Peak to Peak)
Efficiency at WET (230VAC)
Protections
Short Circuit Protection
Overload Protection
Reverse Polarity Protection (fused)
Over Temperature Protection
OVP (Output Tracking/ Fixed Over Voltage Protection Selectable)
Thermal decrease of charger output power
Thermostatically Controlled Variable Speed Fan (0 - full speed)
Approvals
Charge Cycle, Protection Indication
Separate LED for Bulk, Absorption, Float and Fault Mode
Charger ON / OFF LED Indicator
Power ON / OFF Switch
Remote Control & Temperature Sensor Socket
Plastic panel & Electro-galvanized steel housing w/Mounting flange

Models
Input Voltage Range
Output Voltage
Continuous Output Current
Max. Output Current at 30% duty cycle
No Load Current
Ripple & Noise (peak-peak)
Ripple & Noise (r.m.s.)
Load Regulation
Line Regulation (20-30V variation)
Efficiency
Protections

SDC - 5205
SDC - 5208
SDC - 5212
SDC - 5220
18 - 38VDC
13.8VDC
13.2VDC
5A
7A
12A
18A
7A
12A
16A
20A
<20mA
<30mA
<50mA
<100mA
100mV
300mV
10mV
10mV
10mV
25mV
50mV
100mV
50mV
>89%
>90%
>90%
>90%
OVP (Output Over Voltage Protection), Loss of earth protection self reset protection:
a) Reverse Polarity, b) Overload, c) Short Circuit

Indicators
Input & Output Connection Type
Cooling System
Max. Operating Temperature
Internal Input Fuse (glass type)
Approvals

Green LED: Operate


Red LED: Fault
Push-on Flat Blade Connectors
Natural Convection
-10C to 50C
8A
12A
CE EN 61000-6-3 ;
CE EN 61000-6-3 ;
EN 61000-6-1
EN 61000-6-1

20A
CE EN 61000-6-3 ;
EN 61000-6-1

NIL
CE EN 61000-6-3 ;
EN 61000-6-1

Dimensions (WxHxD)

77x75x32 mm
3x3x1.3 inch

142x75x32 mm
5.6x3x1.3 inch

162x75x32 mm
6.3x3x1.3 inch

Weight
Accessory

190g
6.7oz.
230g
8oz.
380g
13.4oz.
Clip-on Mounting Bracket set and Screw, Slip-on Receptacles

96x75x32 mm
3.8x3x1.3 inch

All values are based on the Standard ambient Temperature 25C and Pressure 0.1Mpa.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

365g

13oz.

Dimension (WxHxD)
Weight
Included Accessories (spare fuse, temperature sensor)
Optional Accessories (remote control panel)
Recommended Battery Capacity Range

HBC - 1305
Yes
1A / 2A

HBC - 1310
Yes
2A / 4A

Absorption
28.8V
29.2V
28.6V
28.2V
28.6V
30.2V
24V - 32V
24V - 32V
31V
5A

Float
27.0V
27.2V
26.4V
27.4V
27.6V
27.6V

10A

<24.6V
1/2 of the charging current
<200mV
>79%
Yes
Yes
Yes
Yes
Yes
Yes
Yes
CE

EN 60335

EN 55014

>83%
Yes
Yes
Yes
Yes
Yes
Yes
Yes
EN 62233

Yes
Yes
Yes
Yes
Yes
200x80x250 mm
2.5 kg

Yes
Yes
Yes
Yes
Yes
200x80x250 mm
2.6 kg

Yes
Not Included
8AH to 50AH

Yes
Not Included
16AH to 100AH

All values are based on the Standard ambient Temperature 25C and Pressure 0.1Mpa.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE