Datasheet

MICROOPTO
MOS 24VDC/5-33VDC 10A

Weidmller Interface GmbH & Co. KG


Klingenbergstrae 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-2083
www.weidmueller.com

The MICROOPTO SOLENOID solid-state relay is used


especially as switching amplifier for actuators up to 24 V DC
and 10 A with inductive loads such as solenoid valves and
contactors. A potential-free signalling contact transmits errors,
such as short circuit to the controller. The MICROOPTO
SOLENOID solid-state relay is short-circuit-proof and
protected against power-related transients and voltage peaks
by extensive protective circuits. The closed housing also offers
a high level of protection against contact.

General ordering data


Order No.
Part designation
Version
GTIN (EAN)
Qty.

8937940000
MOS 24VDC/5-33VDC 10A
MICROOPTO, Solid-state relay, 5...33 V DC, 10
A, Screw connection
4032248716173
1 pc(s).

Creation date October 15, 2010 8:49:11 AM CEST


Last update 30.08.2010 / We reserve the right to make technical changes.

Datasheet
MICROOPTO
MOS 24VDC/5-33VDC 10A

Weidmller Interface GmbH & Co. KG


Klingenbergstrae 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-2083
www.weidmueller.com

Technical data
Dimensions
Length
Height

90 mm
98 mm

Width

6.1 mm

-25 C...+60 C

Storage temperature

-40 C...+80 C

Input frequency
Protective circuit, control side

50 Hz
Varistor, reverse polarity
protection
Error LED red; Status LED
green

Temperature
Ambient temperature (operational)

Probability of failure
MTTF

399 Years

Approvals
Approvals institutes

CULUS; GERMLLOYD;
GOSTME25; CE

Control side
Dropout voltage
Power rating
Rated control voltage
making voltage

< 13 V
400 mW
24 V DC 20 %
> 18 V

Status display on control side

General data
Alarm contact
Humidity
Conductor connection system

5...48 V DC / 0.1 A
40C / 93% rel. humidity, no
condensation
Screw connection

Standards
Flammability class UL 94
Solid-state type

EN 50178 GL 2003-Vl-Abs. 9
IEC 62314 UL508
V-0
POWER MOS-FET

Insulation coordination (EN 50 178)


Clearance and creepage distances for
control/load side
Pollution severity
Rated voltage

> 3 mm
2
300 V

Overvoltage category
Rated impulse withstand voltage

III
4 kV (1.2 / 50 s)

10 A
LC A
10 A
Resistance
typical. 250 s

Leakage current
Protective circuit, load side
Rated switching voltage
Switch-off delay
Voltage drop at max. load

< 1 mA
Varistor Current sensor
5...33 V DC
typical. 700 s
approx. 100 mV

EC001504
27-27-09-90

eClass 5.1

27-27-09-90

Load side
Continuous current
Load category
Rated switching current
Short-circuit-proof
Switch-on delay

Classifications
ETIM 3.0
eClass 6.0

Creation date October 15, 2010 8:49:11 AM CEST


Last update 30.08.2010 / We reserve the right to make technical changes.

Datasheet
MICROOPTO
MOS 24VDC/5-33VDC 10A

Technical data

Weidmller Interface GmbH & Co. KG


Klingenbergstrae 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-2083
www.weidmueller.com

Notes
Note, technical data

Suppressor circuitry for inductive loads, 10-cm installation clearance to inductive switching devices

Creation date October 15, 2010 8:49:11 AM CEST


Last update 30.08.2010 / We reserve the right to make technical changes.

Datasheet
MICROOPTO
MOS 24VDC/5-33VDC 10A

Drawings

Weidmller Interface GmbH & Co. KG


Klingenbergstrae 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-2083
www.weidmueller.com

Electric symbol

Creation date October 15, 2010 8:49:11 AM CEST


Last update 30.08.2010 / We reserve the right to make technical changes.