You are on page 1of 76

Industrial Sectional Doors

Depth 42mm
Technical Manual: Issue 01.04.2014

Contents

Contents

Page

Product descriptions
Technical data overview
Overview of track applications

45
67
89

SPU F42
Door leaf made of double-skinned steel sections (625 and 750mm high), Stucco-textured/Micrograin
SPU F42
With wicket door and threshold rail (625 and 750mm high), Stucco-textured/Micrograin
SPU F42
With wicket door with trip-free threshold (625 and 750mm high), Stucco-textured/Micrograin
SPU F42
Door leaf made of double-skinned steel sections (375 and 500mm high), Stucco-textured/Micrograin
SPU F42
With wicket door and threshold rail (375 and 500mm high), Stucco-textured/Micrograin
SPU F42
With wicket door with trip-free threshold (375 and 500mm high), Stucco-textured/Micrograin
SPU F42
Glazing heights (centre of window from FFL) for door section heights of 500, 625 and 750mm
SPU F42
Calculating the glazing heights (centre of window from FFL)
APU F42/APU F42 Thermo Door leaf made of aluminium extrusions, double-skinned bottom section
APU F42/APU F42 Thermo Bottom section height750with wicket door and threshold rail
APU F42/APU F42 Thermo Bottom section height750 with wicket door and trip-free threshold
APU F42/APU F42 Thermo Bottom section height1500with wicket door and threshold rail
APU F42/APU F42 Thermo Bottom section height1500 with wicket door and trip-free threshold
APU F42 S-Line
Door leaf made of aluminium extrusions, double-skinned bottom section
ALR F42/ALR F42 Thermo
Door leaf made of standard aluminium extrusions or aluminium extrusions with thermal break
ALR F42/ALR F42 Thermo
With wicket door and threshold rail
ALR F42/ALR F42 Thermo
With wicket door with trip-free threshold
ALR F42 S-Line
Door leaf made of standard aluminium extrusions
ALR F42 Glazing
Door leaf made of standard aluminium extrusions
ALR F42 Vitraplan
Door leaf made of standard aluminium extrusions
Glazing/Wicket door arrangements
Infills/fields and glazing series 40
Side doors
NT60
Side doors
Arrangement of possible handing options
Track application N
Normal track application
Track application NA
Normal track application with high-mounted torsion spring shaft
Track application ND
Normal track application with inclination
Track application NH
Normal track application with minimum high-lift
Track application NS
Normal track application with double radius 245
Track application GD
Normal track application with inclination and minimum high-lift
Track application L
Low headroom track application
Track application LD
Low headroom track application with inclination
Track application H
High-lift track application
Track application HA
High-lift track application with high-mounted torsion spring shaft
Track application HD
High-lift track application with inclination
Track application HG
High-lift track application with steep track
Track application HU
High-lift track application with low-mounted torsion spring shaft
Track application RD
High-lift track application with low-mounted torsion spring shaft and inclination
Track application RG
High-lift track application with low-mounted torsion spring shaft and steep track
Track application V
Vertical track application
Track application VA
Vertical track application with high-mounted torsion spring shaft
Track application VU
Vertical track application with low-mounted torsion spring shaft
Track application WG

Vertical track application with low-mounted torsion spring shaft and steep track

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
3032
33
3436
3738
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57

Contents

Contents

Page

Sideroom
Lintel fitting
Bottom edge
Chain hoist
Hand pulley with rope or link steel chain
Ceiling anchors
(L=anchor length, see track applications)
Shaft operator WA 300
Shaft operator WA 400
As a frame-mounted operator
Shaft operator WA 400
With chain box
Shaft operator WA 400
For central mounting
Chain drive operator ITO 400
Operator SupraMaticHT
Door leaf speeds
Infill overview

Detailed door leaf constructions and track applications


as well as fitting examples are provided in this manual.

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

58
59
60
61
62
63
6465
66
67
6870
71
7273
74
75

No part may be reproduced without our prior permission.


All rights reserved.
All dimensions inmm.
Subject to design changes.

Product Descriptions

Door type

Door leaf/wicket door

Sectional door SPUF42, double-skinned steel sections, 625and 750mm high, Stucco-textured/Micrograin
Door leaf

Door sections made of polyurethane-foamed, hot-galvanized sections. Door sections Stucco-textured on inside and outside with uniform
horizontal ribbing, or Micrograin with fine horizontal embossing outside and Stucco-textured inside, 625 and 750mm high, depth 42mm.
All door sections with finger trap protection. Surface protection with polyester-primer coating. Ventilation grilles optional.

Wicket door

Installed in the centre fields of the sectional door. Cannot be installed in the outer fields note the arrangement!
Only opening outwards, LH or RH hinged. Ventilation grilles are not possible in wicket doors.
Attention (for threshold rail): For grid heights 2000, 2125 and 2250, the clear opening height must not be lower than the door height.

Glazing

Glazing frames of anodised aluminium extrusions in the standard version or with thermal breaks or alternatively sections with compound
glazing are possible within the size range shown below. Fewer compound glazings or different arrangements are possible subject
to the minimum distances. Glazing frames are possible from FFL and compound glazing from 625/750mm above FFL.

Sectional door SPUF42, double-skinned steel sections, 375and 500mm high, Stucco-textured/Micrograin
Door leaf

Door sections made of polyurethane-foamed, hot-galvanized sections. Door sections Stucco-textured on inside and outside with uniform
horizontal ribbing, or Micrograin with fine horizontal embossing outside and Stucco-textured inside, 375 and 500mm high, depth 42mm.
All door sections with finger trap protection. Surface protection with polyester-primer coating. Ventilation grilles optional.

Wicket door

Installed in the centre fields of the sectional door. Cannot be installed in the outer fields note the arrangement!
Only opening outwards, LH or RH hinged. Ventilation grilles are not possible in wicket doors.
Attention (for threshold rail): For grid heights 2000 and 2125, the clear opening height must not be lower than the door height.

Glazing

Glazing frames of anodised aluminium extrusions in the standard version or with thermal breaks or alternatively sections with compound
glazing are possible within the size range shown below. Fewer compound glazings or different arrangements are possible subject
to the minimum distances. Glazing frames are possible from FFL and compound glazing from 500mm above FFL.

Sectional door APUF42/APUF42Thermo, aluminium extrusions, double-skinned bottom section


Door leaf

Bottom section of hot-galvanized sections, infilled with polyurethane foam, 750 (standard version), or 1500mm high, Stucco-textured
inside and outside with uniform horizontal ribbing, or Micrograin with fine horizontal embossing outside and Stucco-textured inside.
Surface protection with polyester-primer coating. Other door sections with glazing of anodised aluminium extrusions in the standard
version (APUF42) or with thermal breaks (APUF42Thermo). Depth 42mm. All door sections with finger trap protection.
Infill: clear synthetic double panes, 26mm. Ventilation grilles in the bottom section optional.

Wicket door

Depending on the door type, made of anodised aluminium extrusions in the standard version or with thermal breaks, installed
in the centre fields of the door. Cannot be installed in the outer fields note the arrangement! Only opening outwards,
LH or RH hinged. Ventilation grilles are not possible in wicket doors.
Attention (for threshold rail): If the wicket door has the same number of sections as the sectional door, the clear opening height
must not be lower than the door height (RM).

Sectional door APUF42S-Line, aluminium extrusions, double-skinned bottom section


Door leaf

Bottom section of hot-galvanized sections, infilled with polyurethane foam, 750 (standard version), or 1500mm high, Stucco-textured
inside and outside with uniform horizontal ribbing, or Micrograin with fine horizontal embossing outside and Stucco-textured inside.
Surface protection with polyester-primer coating. Other door sections with glazing of anodised aluminium extrusions in the standard
version. Depth 48.5mm. All door sections with finger trap protection. Infill: clear synthetic double panes, 26mm. Ventilation grilles
in the bottom section optional.

Sectional door ALRF42/ALRF42Thermo, aluminium extrusions


Door leaf

Door sections made of anodised aluminium extrusions in the standard version (ALRF42) or with thermal breaks (ALRF42Thermo).
Depth 42mm. All door sections with finger trap protection. Bottom door section made of PU infill with 26mm Stucco-textured
aluminium sheet cover on both sides, other door sections with 26mm clear synthetic double panes. Ventilation grilles in the bottom
section optional.

Wicket door

Depending on the door type, made of anodised aluminium extrusions in the standard version or with thermal breaks,
installed in the centre fields of the door. Cannot be installed in the outer fields note the arrangement! Only opening outwards,
LH or RH hinged. Ventilation grilles are not possible in wicket doors.
Attention (for threshold rail): If the wicket door has the same number of sections as the sectional door, the clear opening height
must not be lower than the door height (RM).

Sectional door ALRF42 S-Line, aluminium extrusions


Door leaf

Door sections made of anodised aluminium extrusions in the standard version, depth 48.5mm. All door sections with finger trap protection.
Bottom door section made of PU infill with 26mm Stucco-textured aluminium sheet cover on both sides, other door sections with 26mm
clear synthetic double panes. Ventilation grilles in the bottom section optional.

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Product Descriptions

Door type

Door leaf/wicket door

Sectional door ALRF42Glazing, aluminium extrusions


Door leaf

Door sections made of anodised aluminium extrusions in the standard version. Depth 42mm. All door sections with finger trap protection.
All door section infills in 6-mm laminated safety glass. Uniform infill heights.

Sectional door ALRF42Vitraplan, aluminium extrusions


Door leaf

Door sections of standard polyester primer-coated aluminium extrusions. Depth 42mm. All door sections with finger trap protection
and synthetic double panes, 26mm, clear, and 4mm transparent synthetic glazings fitted in front, in a choice of brown or grey.
Ventilation grilles are not possible in the bottom section.

Frame/track application
Enclosed, moulded angle frame with pressed-fitted external seal, made of hot-galvanized steel with screwed safety tracks.

Door lock
Manually operated

Inside locking using a shootbolt, self-locking rotary latch (with track applications that have a low-mounted torsion spring shaft on request)
or self-locking floor locking.

Power-driven

Inside locking using a shootbolt

Counterbalance
Torsion springs, with carrying cables on the side (with a low headroom track application, a combination of carrying chain and carrying cable).
The torsion springs are designed for track applications N, NB, ND, NS, NK, NA, NH, GD, GS, L and LD for at least 25000 closing cycles und for all other track
applications for at least 50000 closing cycles.

Safety-related equipment according to DIN EN 12604


Manually operated doors using a torsion spring with approved catch safety device *)
Manually operated doors that have more than one torsion spring with approved spring safety device *)
over a door height of 5000 mm, additional approved catch safety devices *)
Power-driven doors with break-in-resistant anti-lift kit
Inner and outer finger trap protection
* European patent

Seals
Floor seal made of 3-chamber EPDM profile with flexible adjustment lip, side seal, lintel seal and intermediate seal between the sections.

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Technical Data Overview

Construction and quality features


SPU F42
Resistance to wind load
EN12424
Water tightness
EN12425
Air permeability
EN12426
Acoustic insulation
EN717-1
Thermal insulation
EN13241-1, appendix BEN12428

Fire protection
Design
Door sizes
Space requirements
Material, door leaf

Surface, door leaf

Wicket door
Side door
Glazings

Seals
ThermoFrame
Locking systems
Anti-lift kit
Safety equipment

Fastening options

Door without wicket door, class


Door with wicket door, LZ4000, class
Door with wicket door, LZ>4000, class

36)
36)
27)

Door without wicket door, class

3 (70Pa)

Door without wicket door, class


Door with wicket door, class
Door without wicket door R=. . . dB
Door with wicket door R=. . . dB
Door without wicket door, U=W/(mK)2)
- Optional triple glazing, U=W/(mK)2)
- Optional climatic double panes (single-pane safety glass) U=W/(mK)2)
- Optional double panes (single-pane safety glass) U=W/(mK)2)
Door with wicket door, U=W/(mK)2)
- Optional triple glazing, U=W/(mK)2)
- Section, U=W/(mK)
Class
Self-supporting
Depth, mm
Max. width mm, LZ
Max. height mm, RM3)
From page39
Steel, double-skinned, 42mm
Aluminium, standard profile
Aluminium, profile with thermal break
Galvanized steel, coated RAL9002
Galvanized steel, coated RAL9006
Galvanized steel, coated RAL to choose
Anodised aluminium E6/C0 (previously E6/EV1)
Aluminium coated in RAL to choose
With trip-free threshold
Matching the door
Type A section window
Type D section windows
Type E section windows
Aluminium glazing frames
All-round on 4 sides
Intermediate seal between the door sections
PVC hard/soft seal
Internal latches
Outside/inside locking
For doors of up to 5m with shaft operator
Finger trap protection
Side trap guard
Spring break safeguard for manual operation
Safety catch for doors with shaft operator
Concrete
Steel
Brickwork
Others on request

28)
19)
25
24
1.0 (0.944))

1.2 (1.24))

0.5
B2

42
8000
7500

=Standard
=Optional
7) Class 2=0.45kN/m or 96 km/h

1) With optional double pane (single-pane safety glass)

4) Optionally with Thermoframe

2) For a door surface of 50005000mm

5) Door width up to 5500mm

8) Class 2=12m3/m2h

3) Door height above 7000 mm on request


(not with door type ALRF42Glazing)

6) Class 3=0.7kN/m or 120 km/h

9) Class 1=24m3/m2h

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Technical Data Overview

APU F42
S-Line
36)

APU F42

ALR F42
S-Line
36)

ALR F42

36)
36)
27)

APU F42
Thermo
36)
36)
27)

36)
36)
27)

ALR F42
Thermo
36)
36)
27)

ALR F42
Vitraplan
36)

ALR F42
Glazing
36)

3 (70Pa)

3 (70Pa)

3 (70Pa)

3 (70Pa)

3 (70Pa)

3 (70Pa)

3 (70Pa)

3 (70Pa)

28)

23

3.3 (3.24))
2.8 (2.74))

B2

42/48.5
5000
7500

28)
19)
23
22
3.4 (3.34))
3.0 (2.94))
2.5 (2.44))
3.4 (3.34))
3.6 (3.64))
3.2 (3.14))

B2

42
8000
7500

28)
19)
23
22
2.9 (2.84))
2.5 (2.44))
2.0 (1.94))
2.9 (2.84))
3.1 (3.14))
2.7 (2.64))

B2

42
7000
7500

28)

22

3.5 (3.44))
3.0 (2.94))

B2

48.5
5000
7500

28)
19)
23 (301))
22
3.6 (3.64))
3.2 (3.14))
2.7 (2.64))
3.6 (3.64))
3.8 (3.84))
3.4 (3.44))

B2

42
8000
7500

28)
19)
23 (301))
22
3.0 (3.04))
2.6 (2.54))
2.1 (2.04))
3.0 (3.04))
3.2 (3.24))
2.8 (2.84))

B2

42
7000
7500

28)

23

3.2 (3.44))
3.0 (2.94))

B2

42
6000
7500

28)

301)

6.1 (6.14))

2.7 (2.64))
3.8 (3.84))

B2

42
5500
4000

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Overview of Track Applications

LD
Normal track application

Like track application L, with inclination


Door height RM5000mm

NA

H
Like track application N, with high-mounted
torsion spring shaft

High-lift track

Door height RM5000mm

ND

HA
Like track application N, with inclination

Like track application H, with high-mounted


torsion spring shaft
Door height RM3500mm

NH

HD
Like track application N, with minimum high-lift

NS

Like track application H, with inclination

HG
Like track application N, with double radius 245

Like track application H, with steep track


and minimum slot width of 120mm
(for loading ramp doors)
Door width LZ 3500mm
Door height RM5000mm
Not possible for door types APUF42
S-Line/ALRF42 S-Line/ALRF42 Glazing and
doors with wicket door and with real glass infill!

Door height RM5000mm

GD

HU
Like track application NH, with inclination
(maximum 27)

Like track application H, with low-mounted


torsion spring shaft

Door height RM5000mm

Door height RM5000mm

RD
Low headroom track application

Like track application HU, with inclination

Door height RM5000mm

Door height RM5000mm

RG
Like track application HU, with steep track
and minimum slot width of 120mm
(for loading ramp doors)
Door width LZ 3500mm
Door height RM5000mm
Not possible for door types APUF42
S-Line/ALRF42 S-Line/ALRF42 Glazing and
doors with wicket door and with real glass infill!

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Overview of Track Applications

VA
Vertical track application
(additional hand pulley required for manually
operated doors!)

Like track application V, with high-mounted


torsion spring shaft
(additional hand pulley required for manually
operated doors!)
Door height RM3500mm

VU

WG
Like track application V, with low-mounted
torsion spring shaft
(additional hand pulley required for manually
operated doors!)

Like track application VU, with steep track


and minimum slot width of 120mm
(for loading ramp doors)
(additional chain hoist required for manually
operated doors!)
Door width LZ 3500mm
Door height RM5000mm
Not possible for door types APUF42
S-Line/ALRF42 S-Line/ALRF42 Glazing and
doors with wicket door and with real glass infill!

Note:
An in-factory technical inspection is required for the following
track applications.
NK

GS
Like track application NS, but the degree values
of both radii are adapted to the situation on site

Like track application NH with 245


double radius

Door height RM5000mm

Door height RM5000mm

HS

HK
Like track application H, with double radius 245

VS

Like track application HS, but the degree values


of both radii are adapted to the situation on site

WS
Like track application V, but in the top sections
the tracks are diverted using radii where the ceiling
is too low
(additional hand pulley required for manually
operated doors!)

RS

Like track application VU, but in the top sections


the tracks are diverted using radii where the ceiling
is too low
(additional hand pulley required for manually
operated doors!)

RK
Like track application HU, with 245
double radius

Like track application RS, but the degree values


of both radii are adapted to the situation on site

Door height RM5000mm

Door height RM5000mm

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Sectional Door SPU F42


Double-skinned steel sections
625 and 750mm high
Stucco-textured/Micrograin
External views
Glazing frames

Compound glazing type D

Compound glazing type A

Compound glazing type E


E*
E**
***

Fitting area for frames with glazing


Fitting area for compound glazing
Optionally with wide rail extrusions (91mm)

Range 1

Range 2

RM

Range 3

Size range

7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

3
(see table1)

SPB 52
LZ

10

In the size range shown, any door width can


be manufactured in 10-mm increments and
any door height in the 125-mm grid, taking the
min.ceiling height into account. Intermediate
heights using aluminium glazing frames
or shortened top door section are possible.
Notes:
When using a shaft operator (installation
example 5), the door lock is always
on the side opposite the operator
For a view of the matching appearance
with doors with wicket doors see
page3032.
Number of glazings, matching view
to series40, see page33.
Table 1:
Number of compound glazings per door section
Type

Quantity

Door width

A: 12001670mm
D: 12001630mm

A: 16803000mm
D: 16403000mm

30104500mm

45105500mm

55106000mm

12001850mm

18603000mm

30104500mm

45105500mm

55106000mm

A, D

Number of compound glazings per door section


Number of ventilation grilles, ventilation area
40cm per grille

1500
2000
2250
2500
2750
3000
3250
3500
3750
4000
4250
4500
4750
5000
5250
5500
5750
6000

Number of infills/fields2

[A]
TH 625
TH 750
7500

10
7375
1
+
9
7250
2
+
8
7125
3
+
7
7000
4
+
6
6875
5
+
5
6750

9
6625
1
+
8
6500
2
+
7
6375
3
+
6
6250
4
+
5
6125
5
+
4
6000

8
5875
1
+
7
5750
2
+
6
5625
3
+
5
5500
4
+
4
5375
5
+
3
5250

7
5125
1
+
6
5000
2
+
5
4875
3
+
4
4750
4
+
3
4625
5
+
2
4500

6
4375
1
+
5
4250
2
+
4
4125
3
+
3
4000
4
+
2
3875
5
+
1
3750

5
3625
1
+
4
3500
2
+
3
3375
3
+
2
3250
4
+
1
3125
5

3000

4
2875
1
+
3
2750
2
+
2
2625
3
+
1
2500
4

2375
3
+
1****
2250

3
2125
1
+
2
2000
2
+
1
1875
3

Number of infills/fields per aluminium frame

On request
[A]
RM
LZ

No. of door sections


Grid height
Clear frame dimensions (from 1200)
up to LZ

SPB
TH
****

Rail width
Door section height
Top door section 500 mm

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Sectional Door SPU F42


With Wicket Door and Threshold Rail
Double-skinned steel sections
625 and 750mm high, Stucco-textured/Micrograin
External views
** Note on fitting compound glazings:
For door widths from 17503000 mm, a compound glazing
can only be fitted into the wicket door. No compound glazing
can be fitted to the left or right of the wicket door.

625 / 750 625 /750 625 /750

DRH

Lever heights (DRH)


Bottom door section 625=955.5
Bottom door section 750=1080.5

LDBS

38,5 + 10
0

DHS

Clear passage width (LDBS)=940mm*


* For a door width of 17501840mm, the clear passage width is 833mm.

LZ

Size range
In the size range shown, any door width can be manufactured in 10-mm increments and any door height in the 125-mm grid, taking the min.ceiling
height into account. Intermediate heights using aluminium glazing frames or shortened door section above wicket door are possible.

3
2

[A]
[D]
TH 625
TH 750
7500

10
2205
7375
1
+
9
2205
7250
2
+
8
2205
7125
3
+
7
2205
7000
4
+
6
2205
6875
5
+
5
2205
6750

9
2205
6625
1
+
8
2205
6500
2
+
7
2205
6375
3
+
6
2205
6250
4
+
5
2205
6125
5
+
4
2205
6000

8
2205
5875
1
+
7
2205
5750
2
+
6
2205
5625
3
+
5
2205
5500
4
+
4
2205
5375
5
+
3
2205
5250

7
2205
5125
1
+
6
2205
5000
2
+
5
2205
4875
3
+
4
2205
4750
4
+
3
2205
4625
5
+
2
2080
4500

6
2205
4375
1
+
5
2205
4250
2
+
4
2205
4125
3
+
3
2205
4000
4
+
2
2080
3875
5
+
1
1955
3750

5
2205
3625
1
+
4
2205
3500
2
+
3
2205
3375
3
+
2
2080
3250
4
+
1
1955
3125
5

1830
3000

4
2205
2875
1
+
3
2205
2750
2
+
2
2080
2625
3
+
1
1955
2500
4

1830
2375
3
+
1***
1830
2250

3
2205
2125
1
+
2
2080
2000
2
+
1
1955
Number of infills/fields per aluminium frame

Number of compound glazings per door section**

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

On request
Glazings on request
[A]
[D]
SH
SPB
TH
DHS
RM
LDBS
DRH
LZ
***

No. of door sections


Clear passage heights (DHS) of wicket door
to grid height
Threshold height (200)
Rail width
Door section height
Clear passage height of wicket door
Grid height
Clear passage width
Lever height
Clear frame dimensions (from 1750)
Top door section 500 mm

Number of ventilation grilles, ventilation area


40cm per grille

(Number of infills/fields 1)2


2250

Notes:
When using a shaft operator (installation
example 5), the door lock is always
on the side opposite the operator
For a view of the matching appearance
with doors without wicket doors see
page3032.
Number of glazings, matching view
to series40, see page33.

5500

7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000

2000

Range 1

Range 2

RM

Range 3

SH

SPB 52
LZ

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

11

Sectional Door SPU F42


With Wicket Door with Trip-Free Threshold
Double-skinned steel sections
625 and 750mm high, Stucco-textured/Micrograin
External views
** Note on fitting compound glazings:
For door widths from 17503000 mm, a compound glazing
can only be fitted into the wicket door. No compound glazing
can be fitted to the left or right of the wicket door.

625 / 750 625 /750 625 /750

DRH

Lever heights (DRH)


Bottom door section 625=955.5
Bottom door section 750=1080.5

LDBS

38,5 + 10
0

DHS

Clear passage width (LDBS)=940mm*


* For a door width of 17501840mm, the clear passage width is 833mm.

LZ

Size range
In the size range shown, any door width can be manufactured in 10-mm increments and any door height in the 125-mm grid, taking the min.ceiling
height into account. Intermediate heights using aluminium glazing frames or shortened door section above wicket door are possible.

7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000

3
2

[A]
[D]
TH 625
TH 750
7500

10
2205
7375
1
+
9
2205
7250
2
+
8
2205
7125
3
+
7
2205
7000
4
+
6
2205
6875
5
+
5
2205
6750

9
2205
6625
1
+
8
2205
6500
2
+
7
2205
6375
3
+
6
2205
6250
4
+
5
2205
6125
5
+
4
2205
6000

8
2205
5875
1
+
7
2205
5750
2
+
6
2205
5625
3
+
5
2205
5500
4
+
4
2205
5375
5
+
3
2205
5250

7
2205
5125
1
+
6
2205
5000
2
+
5
2205
4875
3
+
4
2205
4750
4
+
3
2205
4625
5
+
2
2080
4500

6
2205
4375
1
+
5
2205
4250
2
+
4
2205
4125
3
+
3
2205
4000
4
+
2
2080
3875
5
+
1
1955
3750

5
2205
3625
1
+
4
2205
3500
2
+
3
2205
3375
3
+
2
2080
3250
4
+
1
1955
3125
5

1830
3000

4
2205
2875
1
+
3
2205
2750
2
+
2
2080
2625
3
+
1
1955
2500
4

1830
2375
3
+
1***
1830
2250

3
2125
2125
1
+
2
2000
2000
2
+
1
1875
Number of infills/fields per aluminium frame

Number of compound glazings per door section**

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

On request
Glazings on request
[A]
[D]
SH
SPB
TH
DHS
RM
LDBS
DRH
LZ
***

No. of door sections


Clear passage heights (DHS) of wicket door
to grid height
Threshold height (rising from 5 to 10)
Rail width
Door section height
Clear passage height of wicket door
Grid height
Clear passage width
Lever height
Clear frame dimensions (from 1750)
Top door section 500 mm

Number of ventilation grilles, ventilation area


40cm per grille

(Number of infills/fields 1)2


2000

Notes:
When using a shaft operator (installation
example 5), the door lock is always
on the side opposite the operator
For a view of the matching appearance
with doors without wicket doors see
page3032.
Number of glazings, matching view
to series 40, see page33.

6000

Range 1

Range 2

RM

Range 3

SH

SPB 52
LZ

12

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Sectional Door SPU F42


Double-Skinned Steel Sections
375 and 500mm high
Stucco-textured/Micrograin
External views
Glazing frames

Compound glazing type A

Compound glazing type D


E*
E**
***

Fitting area for frame 500 with glazing


Fitting area for compound glazing
Optionally with wide rail extrusions (91mm)

7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875
2
2

7750

7500

7250

7000

6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

In the size range shown, any


door width can be manufactured
in 10-mm increments and any
door height in the 125-mm grid,
taking the min.ceiling height into
account. Intermediate heights
using aluminium glazing frames
or shortened top door section
are possible.
Notes:
Thermo glazing frames only
up to a width of 7000 mm.
For a view of the matching
appearance with doors
with wicket doors see
page 3032.
Number of glazings,
matching view to series 40,
see page 33.
On request
[A]
RM
LZ

No. of door sections


Grid height
Clear frame dimensions (from1200)
up to LZ

SPB
TH
****

Rail width
Door section height
See table 1 on page10

Number of compound glazings


per door section
Number of ventilation grilles,
ventilation area 40cm per grille

Number of infills/fields2
2000

[A]
TH 375
TH 500
7500

15
7375
1
+
14
7250
2
+
13
7125
3
+
12
7000

14
6875
1
+
13
6750
2
+
12
6625
3
+
11
6500

13
6375
1
+
12
6250
2
+
11
6125
3
+
10
6000

12
5875
1
+
11
5750
2
+
10
5625
3
+
9
5500

11
5375
1
+
10
5250
2
+
9
5125
3
+
8
5000

10
4875
1
+
9
4750
2
+
8
4625
3
+
7
4500

9
4375
1
+
8
4250
2
+
7
4125
3
+
6
4000

8
3875
1
+
7
3750
2
+
6
3625
3
+
5
3500

7
3375
1
+
6
3250
2
+
5
3125
3
+
4
3000

6
2875
1
+
5
2750
2
+
4
2625
3
+
3
2500

5
2375
1
+
4
2250
2
+
3
2125
3
+
2
2000

4
1875
1
+
3
Number of infills/fields
per aluminium frame

8000

1
****

1500

Range 1

Range 2

RM

Range 3

Size range

SPB 52
LZ

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

13

Sectional Door SPU F42


With Wicket Door and Threshold Rail
Double-skinned steel sections
375 and 500mm high, Stucco-textured/Micrograin
External view
*** Note on fitting compound glazings:
For door widths from 17503000 mm, a compound glazing
can only be fitted into the wicket door. No compound glazing
can be fitted to the left or right of the wicket door.
Clear passage width (LDBS)=940mm*
500

* For a door width of 17501840mm, the clear passage width is 833mm.

DRH

500

DHS

500

500

Lever heights (DRH)


Bottom door section 500=830.5
Bottom door section 625=955.5 (only for SH2)

38,5 + 10
0

LDBS
LZ

Size range
In the size range shown, any door width can be manufactured in 10-mm increments and any door height in the 125-mm grid, taking the min.ceiling
height into account. Intermediate heights using aluminium glazing frames or shortened door section above wicket door are possible.
SH2

[A]
TH 375
TH 500
7500

15
7375
1
+
14
7250
2
+
13
7125
3
+
12
7000

14
6875
1
+
13
6750
2
+
12
6625
3
+
11
6500

13
6375
1
+
12
6250
2
+
11
6125
3
+
10
6000

12
5875
1
+
11
5750
2
+
10
5625
3
+
9
5500

11
5375
1
+
10
5250
2
+
9
5125
3
+
8
5000

10
4875
1
+
9
4750
2
+
8
4625
3
+
7
4500

9
4375
1
+
8
4250
2
+
7
4125
3
+
6
4000

8
3875
1
+
7
3750
2
+
6
3625
3
+
5
3500

7
3375
1
+
6
3250
2
+
5
3125
3
+
4
3000

6
2875
1
+
5
2750
2
+
4
2625
1***
4
2500

5
2375
1
+
4
2250
2
+
3
2125
1***
3
2000

4
Number of infills/fields
per aluminium frame

7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
3
2

Number of compound glazings


per door section**

6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
2080
1955
1955
1830
2080
1955

Notes:
Micrograin version only up
to LZ5500mm.
From LZ >5500mm bottom
door section with deviating
heights TH = 625/750 mm
(made of 375/500 mm
sections and 2125 mm
aluminium bottom profile).
For a view of the matching
appearance with doors
without wicket doors see
page3032.
Number of glazings, matching
view to series 40, see page 33.
On request
Glazings on request
[A]
[D]
RM
LZ
SH1
SH2

SPB
TH
DHS
DRH
LDBS
***

No. of door sections


Clear passage heights (DHS)
of wicket door to grid height
Grid height
Clear frame dimensions (from 1750)
Threshold height (200)
Threshold height (325), bottom door
section with 250mm aluminium
bottom section, glazing from 625mm
Rail width
Door section height
Clear passage height of wicket door
Lever height
Clear passage width
TH=625mm

Number of ventilation grilles,


ventilation area 40cm per grille

(Number of infills/fields 1)2


2000

[D]

7000

Range 1

Range 2

RM

Range 3

SH1

SPB 52
LZ

14

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Sectional Door SPU F42


With Wicket Door with Trip-Free Threshold
Double-skinned steel sections
375 and 500mm high, Stucco-textured/Micrograin
External view
*** Note on fitting compound glazings:
For door widths from 17503000 mm, a compound glazing
can only be fitted into the wicket door. No compound glazing
can be fitted to the left or right of the wicket door.
Clear passage width (LDBS)=940mm*

LDBS

38,5

DRH

500/ 500/
625 625

500

Lever heights (DRH)


Bottom door section 500=830.5
Bottom door section 625=955.5

+ 10
0

DHS

500

* For a door width of 17501840mm, the clear passage width is 833mm.

LZ

Size range
In the size range shown, any door width can be manufactured in 10-mm increments and any door height in the 125-mm grid, taking the min.ceiling
height into account. Intermediate heights using aluminium glazing frames or shortened door section above wicket door are possible.
SH2

[A]
TH 375
TH 500
7500

15
7375
1
+
14
7250
2
+
13
7125
3
+
12
7000

14
6875
1
+
13
6750
2
+
12
6625
3
+
11
6500

13
6375
1
+
12
6250
2
+
11
6125
3
+
10
6000

12
5875
1
+
11
5750
2
+
10
5625
3
+
9
5500

11
5375
1
+
10
5250
2
+
9
5125
3
+
8
5000

10
4875
1
+
9
4750
2
+
8
4625
3
+
7
4500

9
4375
1
+
8
4250
2
+
7
4125
3
+
6
4000

8
3875
1
+
7
3750
2
+
6
3625
3
+
5
3500

7
3375
1
+
6
3250
2
+
5
3125
3
+
4
3000

6
2875
1
+
5
2750
2
+
4
2625
1*** +
4
2500

5
2375
1
+
4
2250
2*** +
2
2125
1*** +
3
2000

4
Number of infills/fields
per aluminium frame

7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000

On request
Glazings on request
[A]
[D]
RM
LZ
SH1
SH2
SPB
TH
DHS
DRH
LDBS
***

No. of door sections


Clear passage heights (DHS)
of wicket door to grid height
Grid height
Clear frame dimensions (from 1750)
Threshold height (rising from 5 to 10)
Threshold height (approx.13)
Rail width
Door section height
Clear passage height of wicket door
Lever height
Clear passage width
TH=625mm

Number of ventilation grilles,


ventilation area 40cm per grille
6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
1955
2080
1955
1955
2125
2000
1875

Note:
For a view of the matching
appearance with doors without
wicket doors see page 3032.
Number of glazings, matching
view to series 40, see page 33.

Number of compound glazings


per door section**

(Number of infills/fields 1)2


2250

[D]

7000

2000

Range 1

Range 2

RM

Range 3

SH1

SPB 52
LZ

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

15

Glazing Heights for Matching External Appearance


SPUF42Stucco-Textured
(Centre of window from FFL)
Door section heights 500, 625 and 750mm

Glazing heights for matching external appearance of compound windows typeA and D.
RM

1155

7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875
RM

16

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X

1280
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

1530

1655

X
X

X
X
X
X
X

X
X

X
X
X

X
X

X
X
X
X
X

X
X

X
X
X

X
X

X
X
X
X

X
X
X
X

X
X
X

X
X

X
X
X

X
X

X
X
X

Glazing heights (centre of window from FFL)


1780
1905
2030
2155
2280
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

2405

2530

2655

X
X

X
X
X

X
X

X
X
X

X
X

X
X
X

X
X

X
X
X

X
X

X
X
X

X
X

X
X

X
X

X
X
X

X
X

X
X

X
X
X

X
X
X
X

X
X

X
X
X
X

Grid height

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Calculating the Glazing Heights


(Centre of window from FFL)
Door section heights 500, 625 and 750mm

Calculating the glazing heights for compound windows type A, type D and type E.
See door type for number of door sections and glazing areas. The illustrations correspond to a section depth of 42mm.
Door section height 750mm
Type A

Type D

Type E

Micrograin type A, D, E

750

Glazing height typeE


=x+282.5
=x+282.5+125
=x+345

345

282,5

x ==Sum of door section heights+60mm from FFL

MF

MF

MF

FFL

MF

220

220

750

750

750

Glazing height typeA and D


=x+220
=x+220+125
=x+220+250
=x+345

Door section height 625mm


Type A

Type D

Type E

Micrograin type A, D, E

625

Glazing height typeE


=x+282.5
=x+282.5

282,5

282,5

x ==Sum of door section heights+60mm from FFL

MF

MF
X

MF

FFL

MF

220

220

625

625

625

Glazing height typeA and D


=x+220
=x+220+125
=x+282.5

Door section height 500mm


Type A

Type D

Micrograin type A, D

Glazing height typeE


Not possible!

500

500

500

Glazing height typeA and D


=x+220

220
MF
X

MF

FFL

MF

220

220

x ==Sum of door section heights+60mm from FFL

Calculation example
Option 2

1155

750

1030

750

220

345

625

625

Option 1

Given:
Door type SPUF42; grid height (RM)=3250mm; glazing typeA;
position see below number of door sections (see table of door types)
Door section 625mm=4 units
Door section 750mm=1 unit
Option

Door section/position

Glazing height

in 2nd door section 625mm at position1

750+60+220=1030mm from FFL

in 2nd door section 625mm at position2

750+60+220+125=1155mm from FFL

in 3rd door section 625mm at position1

750+625+60+220=1655mm from FFL

in 3rd door section 625mm at position2

750+625+60+220+125=1780mm from FFL

FFL

MF

Centre of window from FFL

60

60

38,5

38,5

etc.

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

17

Sectional Door APUF42/APUF42Thermo


Aluminium extrusions
Double-skinned bottom section

External view

TH =
*
**

Door heightbottom section height35


Number of door section frames

On request 120mm, so as to match the appearance of a sectional door with wicket door
with trip-free threshold with the same door height.
Optionally with wide rail extrusions (91mm)

Note:
When using a shaft operator (installation example 5), the door lock
is always on the side opposite the operator.
For a view of the matching appearance with doors with wicket doors
see page 3032.
Number of glazings, matching view to series40, see page33.

LZ

Size range
In the size range shown, any door width can be produced in 10-mm increments. Observe min. ceiling height.
n

[A]
7500

6790
6780
8

6790
6780
7

6040
6030
7

6040
6030
6

5290
5280
6

5290
5280
5

4540
4530
5

4540
4530
4

3790
3780
4

3790
3780
3

3040
3030
3

3040
3030
2

2290
2280
2
1

7750

7500

7250

7000

6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

1500

2290
2280
1

1875
1875
Number of infills/fields per aluminium frame
Number of ventilation grilles, ventilation area 40cm
per grille

Number of infills/fields2

SPB 52
LZ

On request
Number of door section frames:
[A]
Bottom section height 750mm (standard)
[B]
Bottom section height 1500mm
RM
Grid height
LZ
Clear frame dimensions (from 1200)

18

SPB
n
TH

[B]
7500

8000

Range 1

Range 2

RM

Range 3

up to 7000 for APU F42 Thermo


7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

Rail width
Number of aluminium frames
Door section height

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Sectional Door APU F42/APU F42 Thermo


With Wicket Door and Threshold Rail
Aluminium extrusions
Bottom section height 750
External view
Lever height on request
Clear passage width (LDBS)=940mm**
Clear passage height of wicket door (DHS)
=n1TH+(bottom section height45)
n1
*
**

Number of frames in the wicket door


Optionally with wide rail extrusions (91mm)
For a door width of 1750-1840mm, the clear passage width is 833mm.

Note:
When using a shaft operator (installation example 5), the door lock
is always on the side opposite the operator.
Micrograin version only up to door width5500mm.
For a view of the matching appearance with doors without wicket
doors see page 3032.
Number of glazings, matching view to series40, see page33.

Size range
In the size range shown, any door width can be produced in 10-mm increments. Observe min. ceiling height.
SH2

RM
DHS
7500
2197
7375
2169
7250
2142
9
7125
2114
7000
2086
6790
6875
2058
6750
2196
6780
6625
2165
6500
2134
8
6375
2103
6250
2071
6040
6125
2040
6000
2195
6030
5875
2159
5750
2124
7
5625
2088
5500
2052
5290
5375
2016
5250
2193
5280
5125
2152
5000
2110
6
4875
2068
4750
2027
4540
4625
1985
4500
2191
4530
4375
2141
4250
2091
5
4125
2041
4000
1991
3790
3875
1941
3750
2188
3780
3625
2125
3500
2063
4
3375
2000
3250
1938
3040
3125
1875
3000
2182
3030
2875
2096
2750
2015
3
2625
1932
2500
1848
2290
2375
2295
2250
2170
2280
2
2125
2045
2000
2000
1920
Number of infills/fields per aluminium frame

n1

Height

2
3

2430
2420

6750

6500

6250

6000

5750

Number of ventilation grilles, ventilation area 40cm per grille


5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

(Number of infills/fields1)2

Height
7500

7000

Range 1

Range 2

RM

Range 3

SH1
7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000

SPB 52
LZ

On request
DHS
DRH
LZ
RM
SPB

Clear passage height of wicket door


Lever height
Clear frame dimensions (from 1750)
Grid height
Rail width

SH1
SH2
n
n1
TH

Threshold height (200)


Threshold height (325)
Number of aluminium frames
Number of aluminium frames in the wicket door
Door section height

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

19

Sectional Door APUF42/APUF42Thermo


With Wicket Door with Trip-Free Threshold
Aluminium extrusions
Bottom section height 750
External view
Lever height on request
Clear passage width (LDBS)=940mm***
Clear passage height of wicket door (DHS)
=n1TH+(bottom section height45*)
n1
*
**
***

Number of frames in the wicket door


Attention: If there is no frame above the wicket door, then 90 instead of 45.
Optionally with wide rail extrusions (91mm)
For a door width of 17501840mm, the clear passage width is 833mm.

Note:
When using a shaft operator (installation example 5), the door lock
is always on the side opposite the operator.
For a view of the matching appearance with doors without wicket
doors see page3032.
Number of glazings, matching view to series40, see page 33.

Size range
In the size range shown, any door width can be produced in 10-mm increments. Observe min. ceiling height.
SH2

RM
DHS
7500
2197
7375
2169
7250
2142
9
7125
2114
7000
2086
6790
6875
2058
6750
2196
6780
6625
2165
6500
2134
8
6375
2103
6250
2071
6040
6125
2040
6000
2195
6030
5875
2159
5750
2124
7
5625
2088
5500
2052
5290
5375
2016
5250
2193
5280
5125
2152
5000
2110
6
4875
2068
4750
2027
4540
4625
1985
4500
2191
4530
4375
2141
4250
2091
5
4125
2041
4000
1991
3790
3875
1941
3750
2188
3780
3625
2125
3500
2063
4
3375
2000
3250
1938
3040
3125
1875
3000
2182
3030
2875
2096
2750
2015
3
2625
1932
2500
1848
2290
2375
2250
2250
2125
2280
2
2125
2000
2000
2000
1875
Number of infills/fields per aluminium frame

n1

2
3
2

6750

6500

6250

6000

5750

SPB 52
LZ

On request
DHS
LZ
DRH
RM
SPB

20

Clear passage height of wicket door


Clear frame dimensions (from 1750)
Lever height
Grid height
Rail width

SH1
SH2
n
n1
TH

Height

Number of ventilation grilles, ventilation area 40cm per grille


5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

(Number of infills/fields 1)2

Height
7500

7000

Range 1

Range 2

RM

Range 3

SH1
7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000

Threshold height (rising from 5 to 10)


Threshold height (approx.13)
Number of aluminium frames
Number of aluminium frames in the wicket door
Door section height

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

2430
2420

Sectional Door APU F42/APU F42 Thermo


With Wicket Door and Threshold Rail
Aluminium extrusions
Bottom section height 1500
External view
Lever height on request
Clear passage width (LDBS)=940mm**
Clear passage height of wicket door (DHS)
=n1TH+(bottom section height45)
n1 Number of frames in the wicket door
* Optionally with wide rail extrusions (91mm)
** For a door width of 17501840mm, the clear passage width is 833mm.

Note:
When using a shaft operator (installation example 5), the door lock
is always on the side opposite the operator.
Micrograin version only up to door width5500mm.
From LZ>5500mm, the bottom door section consists of a 375/
500mm section and 2125mm aluminium bottom profile.
For a view of the matching appearance with doors without wicket
doors see page3032.
Number of glazings, matching view to series40, see page33.
Size range
In the size range shown, any door width can be produced in 10-mm increments. Observe min. ceiling height.
SH2

RM
7500
7375
7250
8
7125
7000
6790
6875
6750
6780
6625
6500
7
6375
6250
6040
6125
6000
6030
5875
5750
6
5625
5500
5290
5375
5250
5280
5125
5000
5
4875
4750
4540
4625
4500
4530
4375
4250
4
4125
4000
3790
3875
3750
3780
3625
3500
3
3375
3250
3040
3125
3000
3030
2875
2750
2
2625
2500
2290
2375
2250
2280
1
2125
2000
2000
Number of infills/fields per aluminium frame

DHS
2201
2185
2169
2154
2138
2123
2200
2182
2164
2146
2129
2111
2199
2178
2158
2137
2116
2095
2198
2173
2148
2123
2098
2073
2196
2165
2134
2103
2071
2040
2193
2152
2110
2068
2027
1985
2188
2125
2063
2000
1938
1875
2170
2045
1920

n1

6750

6500

6250

6000

5750

Number of ventilation grilles, ventilation area 40cm per grille


5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

(Number of infills/fields 1)2

Height
7500

7000

Range 1

Range 2

RM

Range 3

SH1
7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000

SPB 52
LZ

On request
DHS
DRH
LZ
RM
SPB

Clear passage height of wicket door


Lever height
Clear frame dimensions (from 1750)
Grid height
Rail width

SH1
SH2
n
n1
TH

Threshold height (200)


Threshold height (325)
Number of aluminium frames
Number of aluminium frames in the wicket door
Door section height

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

21

Sectional Door APUF42/APUF42Thermo


With Wicket Door with Trip-Free Threshold
Aluminium extrusions
Bottom section height 1500
External view
Lever height (DRH):
LZ6000= 1080.5
LZ>6000=

830.5

Clear passage width (LDBS)=940mm***


Clear passage height of wicket door (DHS)
=n1TH+(bottom section height45*)
n1
*
**
***

Number of frames in the wicket door


Attention: If there is no frame above the wicket door, then 90 instead of 45.
Optionally with wide rail extrusions (91mm)
For a door width of 1750-1840mm, the clear passage width is 833mm.

Note:
When using a shaft operator (installation example 5), the door lock
is always on the side opposite the operator.
For a view of the matching appearance with doors without wicket
doors see page3032.
Number of glazings, matching view to series40, see page33.
Size range
In the size range shown, any door width can be produced in 10-mm increments. Observe min. ceiling height.
SH2

RM
7500
7375
7250
8
7125
7000
6790
6875
6750
6780
6625
6500
7
6375
6250
6040
6125
6000
6030
5875
5750
6
5625
5500
5290
5375
5250
5280
5125
5000
5
4875
4750
4540
4625
4500
4530
4375
4250
4
4125
4000
3790
3875
3750
3780
3625
3500
3
3375
3250
3040
3125
3000
3030
2875
2750
2
2625
2500
2290
2375
2250
2280
1
2125
2000
2000
Number of infills/fields per aluminium frame

DHS
2201
2185
2169
2154
2138
2123
2200
2182
2164
2146
2129
2111
2199
2178
2158
2137
2116
2095
2198
2173
2148
2123
2098
2073
2196
2165
2134
2103
2071
2040
2193
2152
2110
2068
2027
1985
2188
2125
2063
2000
1938
1875
2125
2000
1875

6750

6500

6250

6000

5750

Number of ventilation grilles, ventilation area 40cm per grille


5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

(Number of infills/fields 1)2

Height
7500

7000

Range 1

Range 2

RM

Range 3

SH1
7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000

SPB 52
LZ

On request
DHS
LZ
RM
SPB

22

Clear passage height of wicket door


Clear frame dimensions (from 1750)
Grid height
Rail width

SH1
SH2
n
n1
TH

Threshold height (rising from 5 to 10)


Threshold height (approx.13)
Number of aluminium frames
Number of aluminium frames in the wicket door
Door section height

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

n1

Sectional Door APU F42 S-Line


Aluminium extrusions
Double-skinned bottom section

72

TH =

Door heightbottom section height77


Number of door section frames

Note:
When using a shaft operator (installation example 5), the door lock
is always on the side opposite the operator.

38,5 + 10
0

750

65

TH

TH

65

TH

65

TH

55

External view

LZ

Size range

7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

n
11

[A]
7450
7440

10
6790
6780

6875
6870
8

9
6125
6120
8
5470
5400
7

6220
6210
7
5550
5540
6
4890
4880

4800
4790
5

6
4140
4130
5
3480
3470
4

4230
4220
4
3570
3560
3
2910
2900

2820
2810
2

3
2
[1]

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

2160
2150

2240
2230

Number of infills/fields per aluminium frame


Number of ventilation grilles, ventilation area 40cm
per grille.

Number of infills/fields2
1500

[B]

5000

Range 1

Range 2

RM

Range 3

In the size range shown, any door width can be produced in 10-mm increments. Observe min. ceiling height.

SPB 65
LZ

On request
[1]
1 1300
Number of door section frames:
[A]
Bottom section height 750mm (standard)
[B]
Bottom section height 1500mm
RM
Grid height

LZ

Clear frame dimensions (from 1200)


up to LZ

SPB
n
TH

Rail width
Number of aluminium frames
Door section height

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

23

Sectional Door ALR F42/ALRF42 Thermo

Door leaf made of standard aluminium extrusions or aluminium extrusions with thermal break

External view
Door height35

TH =
*
**

Number of door section frames

On request 120mm, so as to match the appearance of a sectional door with wicket door
with trip-free threshold with the same door height.
Optionally with wide rail extrusions (91mm)

Note:
When using a shaft operator (installation example 5), the door lock
is always on the side opposite the operator.
For door widths from 5500mm, diagonal struts are fitted into
the bottom door section (not visible with closed infills).
For a view of the matching appearance with doors with wicket
doors see page3032.
Number of glazings, matching view to series40, see page33.

Size range
In the size range shown, any door width can be produced in 10-mm increments. Observe min. ceiling height.
n

6790
6780
9
6040
6030
8
5290
5280
7
4540
4530
6
3790
3780
5
3040
3030
4
2290
2280
3
1

7750

7500

7250

7000

6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

1500

1875
Number of infills/fields per aluminium frame
Number of ventilation grilles, ventilation area 40cm
per grille

Number of infills/fields2

SPB 52
LZ

On request
RM
LZ
SPB
n
TH

24

Height
7500

10

8000

Range 1

Range 2

RM

Range 3

up to 7000 for ALRF42Thermo


7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

Grid height
Clear frame dimensions (from 1200)
Rail width
Number of aluminium frames
Door section height

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Sectional Door ALRF42/ALRF42Thermo


With Wicket Door and Threshold Rail
External view
Lever height on request
Clear passage width (LDBS)=940mm***
Clear passage height of wicket door (DHS)=n1TH45
n1
*
**
***

Number of frames in the wicket door


265.5 with SH2
Optionally with wide rail extrusions (91mm)
For a door width of 17501840mm, the clear passage width is 833mm.

Note:
When using a shaft operator (installation example 5), the door lock
is always on the side opposite the operator.
For door widths from 5500mm, diagonal struts are fitted into
the bottom door section (not visible with closed infills).
For a view of the matching appearance with doors without wicket
doors see page3032.
Number of glazings, matching view to series40, see page33.
Size range
In the size range shown, any door width can be produced in 10-mm increments. Observe min. ceiling height.
SH2

RM
DHS
7500
2195
7375
2157
7250
2120
10
7125
2082
7000
2045
6790
6875
2007
6750
2193
6780
6625
2152
6500
2110
9
6375
2068
6250
2027
6040
6125
1985
6000
2192
6030
5875
2145
5750
2098
8
5625
2051
5500
2004
5290
5375
1958
5250
2190
5280
5125
2136
5000
2083
7
4875
2029
4750
1976
4540
4625
1922
4500
2188
4530
4375
2125
4250
2063
6
4125
2000
4000
1938
3790
3875
1875
3750
2184
3780
3625
2109
3500
2034
5
3375
1959
3250
1884
3040
3125
1809
3000
2179
3030
2875
2085
2750
1991
4
2625
1898
2500
1804
2290
2375
2295
2250
2170
2280
3
2125
2045
2000
2000
1920
Number of infills/fields per aluminium frame

n1

Height

3
4

2500
2490

6750

6500

6250

6000

5750

Number of ventilation grilles, ventilation area 40cm per grille


5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

(Number of infills/fields 1)2

Height
7500

7000

Range 1

Range 2

RM

Range 3

SH1
7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000

SPB 52
LZ

On request
DHS
DRH
LZ
RM
SPB

Clear passage height of wicket door


Lever height
Clear frame dimensions (from 1750)
Grid height
Rail width

SH1
SH2
n
n1
TH

Threshold height (181)


Threshold height (306)
Number of aluminium frames
Number of aluminium frames in the wicket door
Door section height

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

25

Sectional Door ALRF42/ALRF42Thermo


With Wicket Door with Trip-Free Threshold
External view
Lever height on request
Clear passage width (LDBS)=940mm***
Clear passage height of wicket door (DHS)=n1TH45*
n1
*
**
***

Number of frames in the wicket door


Attention: If there is no frame above the wicket door, then 90 instead of 45.
Optionally with wide rail extrusions (91mm)
For a door width of 17501840mm, the clear passage width is 833mm.

Note:
When using a shaft operator (installation example 5), the door lock
is always on the side opposite the operator.
For door widths from 5500mm, diagonal struts are fitted into
the bottom door section (not visible with closed infills).
For a view of the matching appearance with doors without wicket
doors see page3032.
Number of glazings, matching view to series40, see page33.

Size range
In the size range shown, any door width can be produced in 10-mm increments. Observe min. ceiling height.
SH2

RM
DHS
7500
2195
7375
2157
7250
2120
10
7125
2082
7000
2045
6790
6875
2007
6750
2193
6780
6625
2152
6500
2110
9
6375
2068
6250
2027
6040
6125
1985
6000
2192
6030
5875
2145
5750
2098
8
5625
2051
5500
2004
5290
5375
1958
5250
2190
5280
5125
2136
5000
2083
7
4875
2029
4750
1976
4540
4625
1922
4500
2188
4530
4375
2125
4250
2063
6
4125
2000
4000
1938
3790
3875
1875
3750
2184
3780
3625
2109
3500
2034
5
3375
1959
3250
1884
3040
3125
1809
3000
2179
3030
2875
2085
2750
1991
4
2625
1898
2500
1804
2290
2375
2250
2250
2125
2280
3
2125
2000
2000
2000
1875
Number of infills/fields per aluminium frame

n1

3
4
3

6750

6500

6250

6000

5750

SPB 52
LZ

On request
DHS
DRH
LZ
RM
SPB

26

Clear passage height of wicket door


Lever height
Clear frame dimensions (from 1750)
Grid height
Rail width

SH1
SH2
n
n1
TH

Height

Number of ventilation grilles, ventilation area 40cm per grille


5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

(Number of infills/fields 1)2

Height
7500

7000

Range 1

Range 2

RM

Range 3

SH1
7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000

Threshold height (rising from 5 to 10)


Threshold height (approx.13)
Number of aluminium frames
Number of aluminium frames in the wicket door
Door section height

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

2500
2490

Sectional Door ALRF42S-Line


Door leaf made of aluminium extrusions

65

72

OTH

55

External view

Number of door section frames

Note:
When using a shaft operator (installation example 5), the door lock
is always on the side opposite the operator.

UTH
38,5 + 10
0

115

Door height143.5

OTH=TH+68
UTH=TH+97

TH

TH

65

TH

TH =

LZ

Size range

7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

n
12

Height
7430
7420

11
6770
6760
10
6110
6100
9
5440
5430
8
4780
4770
7
4120
4110
6
3460
3450
5
2800
2790
4
3

[1]

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

1875
Number of infills/fields per aluminium frame
Number of ventilation grilles, ventilation area 40cm
per grille

Number of infills/fields2
1500

2130
2125

5000

Range 1

Range 2

RM

Range 3

In the size range shown, any door width can be produced in 10-mm increments. Observe min. ceiling height.

SPB 65
LZ

On request
[1]
RM
LZ

1 1300
Grid height
Clear frame dimensions (from 1200)
up to LZ

SPB

Rail width

n
UTH
TH
OTH

Number of aluminium frames


Bottom door section height
Door section height
Upper door section height

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

27

Sectional Door ALRF42Glazing


Door leaf made of standard aluminium extrusions

OTH

60

External view

TH =

Door height119
Number of door section frames

TH

120

56,5*

TH

UTH=TH+84785
OTH=TH35
*

76 with optional wide rail extrusions (91mm)

38,5 + 010

UTH

TH

Note:
When using a shaft operator (installation example 5), the door lock
is always on the side opposite the operator.
All track applications on request.

LZ

Size range
In the size range shown, any door width can be produced in 10-mm increments. Observe min. ceiling height.

4000
3625
3620
5
2930
2920
4

5500

5250

5000

4750

4250

4000

3750

3500

3250

SPB 52**

** Optionally with wide rail extrusions (91mm)

LZ

RM
LZ

Grid height
Clear frame dimensions (from 2000)
up to LZ

SPB
n
UTH

Rail width
Number of aluminium frames
Bottom door section height

28

TH
OTH

2230
2220

1875
Number of infills/fields per aluminium frame

2
3000

2750

2500

2250

1 3330

Height

4500

Range 1

RM

n
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

Door section height


Upper door section height

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Sectional Door ALRF42Vitraplan


Door leaf made of standard aluminium extrusions

26

Door height35

TH =

TH

TH

10

TH

External view

Number of door section frames

38,5 + 10
0

TH

TH

Note:
When using a shaft operator (installation example 5), the door lock
is always on the side opposite the operator.
For door widths from 5500mm, diagonal struts are fitted into
the bottom door section.

LZ

Size range
In the size range shown, any door width can be produced in 10-mm increments. Observe min. ceiling height.
Height
7500

10
6790
6780
9
6040
6030
8
5290
5280
7
4540
4530
6
3790
3780
5
3040
3030
4
2290
2280
3
1875
Number of infills/fields per aluminium frame
6000

5750

5500

5
5250

5000

4750

4500

4250

4
4000

3500

3250

3000

3
2750

2500

2250

3750

Range 1

Range 2

RM

Range 3

n
7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

SPB 91
LZ

On request
RM
LZ
SPB
n
TH

Grid height
Clear frame dimensions (from 2000)
Rail width
Number of aluminium frames
Door section height

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

29

Glazing/Wicket Door Arrangements


Sectional doors with 3 infills/fields

Glazing arrangements external view


Sectional door SPUF42
with wicket door with trip-free threshold

Sectional door SPU 42,


matching doors with wicket door

Sectional door SPUF42


with standard window division

Sectional door APUF42


with wicket door with trip-free threshold

Sectional door APUF42,


matching doors with wicket door

Sectional door APUF42


with standard window division

Sectional door ALRF42


with wicket door with trip-free threshold

Sectional door ALRF42,


matching doors with wicket door

Sectional door ALRF42


with standard window division

Arrangement of the wicket door


LZ 4500

30

Notes:
Clear passage width (LDBS)=940mm.
Wicket door only opening outwards.

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Glazing/Wicket Door Arrangements


Sectional doors with 4 infills/fields

Glazing arrangements external view


Sectional door SPUF42
with wicket door with trip-free threshold

Sectional door SPU 42,


matching doors with wicket door

Sectional door SPUF42


with standard window division

Sectional door APUF42


with wicket door with trip-free threshold

Sectional door APUF42,


matching doors with wicket door

Sectional door APUF42


with standard window division

Sectional door ALRF42


with wicket door with trip-free threshold

Sectional door ALRF42,


matching doors with wicket door

Sectional door ALRF42


with standard window division

Arrangement of the wicket door


LZ 4510 5500

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Notes:
Clear passage width (LDBS)=940mm.
Wicket door only opening outwards.

31

Glazing/Wicket Door Arrangements


Sectional doors with 5 infills/fields

Glazing arrangements external view


Sectional door SPUF42
with wicket door with trip-free threshold

Sectional door SPU 42,


matching doors with wicket door

Sectional door SPUF42


with standard window division

Sectional door APUF42


with wicket door with trip-free threshold

Sectional door APUF42,


matching doors with wicket door

Sectional door APUF42


with standard window division

Sectional door ALRF42


with wicket door with trip-free threshold

Sectional door ALRF42,


matching doors with wicket door

Sectional door ALRF42


with standard window division

Arrangement of the wicket door


LZ 5510 7000

32

Notes:
Clear passage width (LDBS)=940mm.
Wicket door only opening outwards.

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Infills/Fields and Glazing


Series 40
Number of infills/fields per aluminium frame

Sectional door without wicket door


Aluminium frame type N

Aluminium frame type B

2 3330

4 6670

8
5

Sectional door with wicket door

8000

7750

7500

7250

7000

6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2250

2000

1500

1200

2500

3 1750-3500

Aluminium frame type N

LZ

Number of compound glazings per door section

Sectional door without wicket door


Standard type A

1
1680

Standard type D

1
1640

Standard type E

1
1860

2 2750

3 3650

4 4540

5 5510

Sectional door with wicket door


5

8000

7750

7500

7250

7000

6750

6500

6250

6000

5750

5500

5250

5000

5 5780

4750

4 4830

4500

3750

3500

3250

3 3880

3000

2750

2500

2250

1500

1200

2000

1 1840-2920

Type E

4250

4000

1 17502650

Type A or type D

LZ

LZ

Clear frame dimensions


up to LZ

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

33

*
LF
RAM
BH

34

10

LF

LDB*

LDB*

RAM:
A 1050
D 1000
= 1300

RAM:
A 1050
D 1000
= 1300

LZ

See page 37
Structural opening
Overall frame dimension
Panel height

10

120

LF

BB
LDB
LDH
TH

LZ

120

Panel width
Clear passage width
Clear passage height
Door section height

282,5

10

LF

RAM
1150
1300

LZ

120

SO
LZ
n

282,5

LDB*

10

LF

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

LDB*

RAM
1150
1300

120

LZ

Bottom section height


Clear frame dimensions
Number of door sections/aluminium frames

625

282,5
625

625

BB

750

E
10

750

BB

1050

LF

151,5

10

10

120
RAM
770
1300

BH ( 680)

LDB *

500

500

500

500

500

500

375

10

LF
RAM = n x TH + 8, 5
LDH = RAM 73

10
625

LF

282,5

10
10

625

625

120
RAM
770
1300

625

BB
1050

BH ( 360)
73
80,5

625

LDB *

750

LZ

500

500

500

750

625

500

500

1050

500

500

LF
RAM = n x TH + 18,5
LDH = RAM 73

750

1050

LF
RAM = n x TH + 133, 5
LDH = RAM 73

500

1050

LF
RAM = 1990/2115
LDH = RAM 73

500

500

375

625

BH ( 360)
73
80,5

625

151,5

375

10

500

10

BH ( 360)

500

BH ( 360)
73
170

10
10

750

LF
LZ

1050

625

BB

151,5

RAM
770
1300
LF
RAM = n x TH + 18,5
LDH = RAM 73

750

LF

10

120
750

RAM
770
1300

BH ( 360)

10

BB

LF
RAM = n x TH + 133, 5
LDH = RAM 73

625

LDB *

220

1050

80,5

375

10

500

10

BH ( 360)

500

10

625

500

120

625

LZ

220

500

LDB *

750

A
10

750

A
LF
RAM = n x TH + 133, 5
LDH = RAM 73

500

LZ

1050

A
10

151,5

BB
10

500

BB

BH ( 555)

LF

625

10
RAM
770
1300

345

10

LF

625

1050

BH ( 360)
73
80,5
10
RAM
770
1300

345
625

151,5

LF
RAM = 1990/2115
LDH = RAM 73
10
BB

LF
RAM = n x TH + 8, 5
LDH = RAM 73

750

10

10

BH ( 555)

10

750

1050

LF
RAM = n x TH + 133, 5
LDH = RAM 73

Side Door NT60

With S-ribbed, Stucco-textured/L-ribbed, Micrograin infills

BB

LDB *

120
LZ

BB

LDB *

120
LZ

Side Door NT60

With L-ribbed, Micrograin infills

Compound glazing typeA TH=500

RAM:
A 1050
D 1000
= 1300

Compound glazing typeA TH=625 and 750

RAM:
A 1050
D 1000
= 1300

Compound glazing typeA TH=625/750 and 750/625

RAM:
A 1050
D 1000
= 1300

RAM:
A 1050
D 1000
= 1300

RAM:
A 1050
D 1000
= 1300

RAM:
A 1050
D 1000
= 1300

Compound glazing typeE TH=625

RAM
1150
1300

RAM
1150
1300

Compound glazing typeE TH=750

RAM
1150
1300

(Legend see page 34)

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

35

Side Door NT60

With S-ribbed, Stucco-textured/L-ribbed, Micrograin infills

LZ

RAM
770
1300

LZ
120

10

LZ

10

120

TH
TH
TH
LF

RAM
770
1300

Side door NT Vitraplan

(Legend see page 34)

36

114

TH

RAM
770
1300

Side door NT 60 matching door type ALR F42S-Line

RAM
770
1300

TH+35

80,5
120
234
120
LDB *

RAM
770
1300
LF

BB

1050

BH ( 360)
THTH120
155,5

10
TH

10

LF
RAM = n x TH + 18, 5
LDH = RAM 73
185

TH+35
114

TH
TH

TH

80,5

BH ( 360)
THTH234
155,5

120
234
120
1050

TH=750

LF
RAM = n x TH + 133, 5
LDH = RAM 73
185

TH
TH

114

TH
LF

120

BB

LDB *

RAM
770
1300

10

Side door NT 60 matching door type APU F42S-Line

RAM
770
1300

10

LDB*

RAM
770
1300
LF

TH+35

80,5
120
234
120
1050

LDB*

10

10

BB

BH ( 360)
THTH120
155,5

10
TH

Side door NT 60 matching door type ALR F42Thermo


10

LF
RAM = n x TH + 18, 5
LDH = RAM 73

TH+35
TH
TH=750

TH

114

120
234
120
1050

LF
RAM = n x TH + 133, 5
LDH = RAM 73

BB

80,5

10

BH ( 360)
THTH234 155,5

10

Side door NT 60 matching door type APU F42

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

LZ
120

Side Door NT60


Arrangements
Possible handing options

Arrangements
Arrangement 1
Fitting next to the door,
opening outwards,
RH hinged

Arrangement 3
Fitting next to the door,
opening inwards,
LH hinged
Arrangement 5
Fitting in the opening,
opening outwards,
RH or LHhinged
Arrangement 7
Fitting behind the opening,
only opening inwards,
RH or LHhinged

RAM

RAM

LDB

LDB

INTERIOR

LDB

LDB

RAM

RAM

INTERIOR

LDB

RAM

LDB

INTERIOR

INTERIOR

RAM

Arrangement 2
Fitting next to the door,
opening outwards,
LH hinged

Arrangement 4
Fitting next to the door,
opening inwards,
RH hinged
Arrangement 6
Fitting in the opening,
opening inwards,
RH or LHhinged

LF
LDB
INTERIOR

RAM

Structural opening
8752000
8752125
10002000
10002125

Ordering size
Overall frame dimensions RAM
8551990
8552115
9801990
9802115

Special sizes: width: RAM 770 to 1300, height: RAM 1865 to 2525 (state overall frame dimension)
Doors with 3-point locking: RAM=min.2025mm
Clear passage dimensions:
Opening angle
136
90

Width
RAM 146
RAM 200

Height
RAM 73

(Legend see page 34)

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

37

Side Door NT60


Arrangements
Possible handing options

Possible handing options


SPU F42, APU F42
with fascia panel

ALR F42,
ALR F42 Thermo
with fascia panel

ALR F42 S-Line

BH

10

APU F42S-Line

RAM

RAM

In the opening
(right illustration with 50mm extension
profile for all-over insulation)

20

20

20

LF

LF

LF

INTERIOR

RAM = LF 10

BH

10

10

SPUF42
No window section,
no compound glazing

AW 60 40
INTERIOR

Behind the opening

73

AW 60 40
INTERIOR

Side door NT 60 flush with sectional door

R 160 60

SW 82,5 35 3,75
INTERIOR

Plugs for metal frame


INTERIOR

Tapping screw
with countersunk head B6.380

R 120 x 60
R 160 x 60
R 200 x 60
INTERIOR

R
AW
SW

38

Box section
Aluminium angle
Steel angle

BH
RAM
LDB

Panel height
Overall frame dimension
Clear passage width

LF

Structural opening

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Track Application: N
Normal track application

ET

Notes:
Observe the permissible size ranges of the door types
on pages1015 and 1829!
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
If using the spring buffer below the track, the clear height
under the track near the spring buffer is reduced by 70 mm.
For version with wicket door, manually operated:
chain hoist recommended!
ALRF42 Vitraplan and ALRF42 Glazing on request

DH
DM

DM

DA

210

WE

820

550

Door weights for roof loads:

Observe min. sideroom, see page 58.

FFL

LZ

125

SPU F42/APU F42 Thermo/ALRF42Thermo = 320 N/m2


APU F42/ALR F42
= 280 N/m2
ALR F42 Glazing
= 560 N/m2

RM + 320

RM + 158

LH

RM 200
F

RM = LDH

BW

DE

INTERIOR

125

WE

DA

N1

390

140

280

N2

440

160

330

N3

550

180

440

With double spring shaft

760

180

650

RM>7000

810

180

700

Clear passage height LDH

Without operator

200 [VL1, VL2 = 300]

INTERIOR

N 1+2
N3

For manual operation

RM+650

With shaft operator

RM+220

For manual operation and shaft operator


with spring buffer below the track

RM+700

For manual operation and shaft operator

RM+220

For manual operation and shaft operator


with spring buffer below the track

WA 300**

LZ5500
Without wicket door

ET=min. distance back


RM+440

Operator
WA400*

RM

RM

RM

Wicket door with threshold

RM100

RM50

RM50

Wicket door without threshold rail

RM150

RM85

RM85

LZ>5500
Without wicket door

RM50

RM50

RM50

Wicket door with threshold

RM100

RM100

RM100

Wicket door without threshold rail

RM175

RM110

RM110

*
**
LDH
RM
BW

ET

Or with chain hoist/pull rope


Track application with inclination
not possible!
Clear passage height
Grid height
Position of shaft support
N 1=RM+310
N 2=RM+335
N 3=RM+415
Min. distance back
N 1+N 2=RM+440
N 3=RM+700
With shaft operator
N 1+N 2=RM+650
With shaft operator N 3=RM+700

DH

DM
WE
H
DA
L
LH
LZ
DE
F

Rear ceiling anchor


N 1+N 2=RM+195
N 3=RM+295
Central ceiling anchor (see page63)
Shaft centre from lintel
Min. headroom (see table)
Distance to ceiling
Anchor length=DERM125
(see page63)
Track height=RM+110
Clear frame dimensions
Ceiling height
Space for fitting the door

Min. headroom
Track size
N1
N2
N3
NA 1
NA 2
ND 1
ND 2
ND 3
NH 1
NH 2
NH 3
NS 1
NS 2
GD 1

Headroom
390
440
550
400
450
390
440
550
610740
660790
770900
390
440
610740

Track size
GD 2
L1
L2
LD 1
LD 2
H4
H5
H8
HA 4
HD 4
HD 5
HD 8
HU 4
HU 5

Headroom
660790
200
200
200
200
880
910
950
890
880
910
950
1760
1760

Track size
RD 4
RD 5
RG 4
RG 5
V6
V7
V9
VA 6
VU 6
VU 7
VU 9
WG6
WG7

Headroom
1760
1760
1760
1760
RM+500
RM+540
RM+635
RM+510
RM+350
RM+350
RM+350
RM+350
RM+350
Dimensions in mm

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

39

Track Application: NA

Normal track application


With high-mounted torsion spring shaft

ET

Door weights for roof loads:

DH
DM
685

Observe min. sideroom, see page 58.

NA 1+2

RM + 320

RM + 158

LH

RM 200

140

290

NA 2

450

160

340

FFL

200 [VL1, VL2 = 300]

ET

125

LZ

INTERIOR

RM+440

For manual operation

RM+650

With shaft operator

RM+220

For manual operation and shaft operator


with spring buffer below the track

LDH
H
DA
RM
DE
BW

INTERIOR

RM = LDH*

WE

400

DA min.

ET=min. distance back

550

BW

DE

125

H min.
NA 1

DA

120
210

WE

SPU F42/APU F42 Thermo/ALRF42Thermo = 320 N/m2


APU F42/ALR F42
= 280 N/m2
ALR F42 Glazing
= 560 N/m2

DM

DH
DM
WE
L
LZ
F

Clear passage height


Max. headroom (depends on order)
Max. distance to ceiling (depends on order)
Grid height
Ceiling height (depends on order)
Position of shaft support
NA 1: BWmin.=RM+320
NA 2: BWmin.=RM+345
NA 1: BWmax.(7820)=DE80
NA 2: BWmax.(7995)=DE105
Min. distance back
NA 1+NA 2=RM+440
With shaft operator
NA 1+NA 2=RM+650
Rear ceiling anchor
NA 1+NA 2=RM+195
Central ceiling anchor (see 63)
Shaft centre from lintel
Anchor length=DERM125 (see page63)
Clear frame dimensions
Space for fitting the door

* Note:
Clear passage height LDH, see track application N
Notes:
Observe the permissible size ranges of the door types
on pages1015 and 1829!
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
If using the spring buffer below the track, the clear height
under the track near the spring buffer is reduced by 70 mm.
ALRF42 Vitraplan and ALRF42 Glazing on request

40

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Track Application: ND
Normal track application
With inclination up to max. 45

* Note:
Clear passage height LDH, see track application N
ET
DH

Note:
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
If using the spring buffer below the track, the clear height
under the track near the spring buffer is reduced by 70 mm.

DM

DA

DM

210

Door weights for roof loads:


SPU F42/APU F42 Thermo/ALRF42Thermo = 320 N/m2
APU F42/ALR F42
= 280 N/m2
ALR F42 Glazing
= 560 N/m2

Track inclined up to 45 to
determine degrees, see table

Observe min. sideroom, see page 58.

45

RM = LDH*

BW

DE

INTERIOR

H30

H>30

ND 1

390

490

ND 2

440

490

ND 3

550

With double spring shaft

760

125

ND 1+2+3

ET=min. distance back

FFL

LZ

a5 and with operator, with long spring buffer

RM+450a6.5

a5 and manual operation with short spring buffer

RM+270a6.5

For manual operation and shaft operator


with spring buffer below the track

a
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

INTERIOR

Max. 45

Max. 30

Max. 16

7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

1500
2000
2250
2500
2750
3000
3250
3500
3750
4000
4250
4500
4750
5000
5250
5500
5750
6000
6250
6500
6750
7000
7250
7500
7750
8000

Range 3
RM

RM+700a6.5

Only to determine the roof slope in degrees(a)

200 [VL1, VL2 = 300]

Range 2

a>5 and with/without operator, with short spring buffer

See the normal track application for all other fitting dimensions.

125

Range 1

RM+450a6.5

LZ

%
1.75
3.49
5.24
6.99
8.75
10.51
12.28
14.05
15.84
17.63
19.44
21.26
23.09
24.93
26.79

X(mm)
17.5
34.9
52.4
69.9
87.5
105.1
122.8
140.5
158.4
176.3
194.4
212.6
230.9
249.3
267.9

a
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

%
28.67
30.57
32.49
34.43
36.40
38.39
40.40
42.45
44.52
46.63
48.77
50.95
53.17
55.43
57.74

a
X(mm)
286.7
305.7
324.9
344.3
364.0
383.9
404.0
424.5
445.2
466.3
487.7
509.5
531.7
554.3
577.4

1000
a
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45

%
60.09
62.49
64.95
67.46
70.03
72.66
75.36
78.13
80.98
83.91
86.93
90.05
93.26
96.57
100

X
X(mm)
600.9
624.9
649.5
674.6
700.3
726.6
753.6
781.3
809.8
839.1
869.3
900.5
932.6
965.7
1000

Note:
Observe the permissible size ranges of the door types
on pages1015 and 1829!
ALRF42 Vitraplan and ALRF42 Glazing on request
LDH
BW

DH

DM
H
DA
L
LZ
DE
ET
RM
F

Clear passage height


Position of shaft support
ND1,30=RM+310
ND2,30=RM+335
ND1+ND2,>30=RM+385
ND3,16=RM+415
Rear ceiling anchor
ND1+ND2=RM+195 a6.5
ND3=RM+295a6.5
Central ceiling anchor (see page63)
Min. headroom (see page 39)
Distance to ceiling on request
Anchor length=DERM+25 (see page63)
Clear frame dimensions (from 1200)
Ceiling height
Min. distance back
Grid height
Space for fitting the door
On request

Dimensions in mm

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

41

Track Application: NH
Normal track application
With minimum high-lift

ET

Door weights for roof loads:


SPU F42/APU F42 Thermo/ALRF42Thermo = 320 N/m2
APU F42/ALR F42
= 280 N/m2
ALR F42 Glazing
= 560 N/m2

DH
DM

DM
250

820

Observe min. sideroom, see page58.


WE
140
160
180

NH 1
NH 2
NH 3

DA

WE

550

ET=min. distance back


NH 1+2

NH3

LH

LH 310

RM = LDH

DE

INTERIOR

BW

DA
280
330
440

2RMLH+1120

For manual operation with long spring buffer (standard)

2RMLH+670

For manual operation with spring buffer below the track

2RMLH+880

For shaft operator with long spring buffer=(LHRM)1000

2RMLH+650

For shaft operator with short spring buffer=(LHRM)>1000

2RMLH+430

For shaft operator with spring buffer below the track

2RMLH+950

All versions

2RMLH+430

For manual operation and shaft operator


with spring buffer below the track

FFL

min. 125

Notes:
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
If using the spring buffer below the track, the clear height
under the track near the spring buffer is reduced by 70 mm.
Observe the permissible size ranges of the door types
on pages1015 and 1829!
ALRF42 Vitraplan and ALRF42 Glazing on request

min. 125

LZ
F

7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

LDH
RM
BW

LH

LZ

42

8000

7750

7500

7250

7000

6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

DH

1500

Range 1

Range 2

RM

Range 3

300

INTERIOR

DM
WE
H
DA
DE
L
LZ
ET
F

Clear passage height


Grid height
Position of shaft support
NH1=LH+200
NH2=LH+225
NH3=LH+305
Track height
Min.=RM+330
max.=RM +460
Rear ceiling anchor
NH1+NH2=2RMLH+645 (long spring buffer)
NH1+NH2=2RMLH+405 (short spring buffer)
NH1+NH2=2RMLH+405 (long spring buffer+operator)
NH3=2RMLH+485
Deckenanker, Mitte (see page63)
Shaft centre from lintel
Min. headroom (see page39)
Distance to ceiling
Ceiling height
Anchor length=DELH+15 (see page63)
Clear frame dimensions (from 1200)
Min. distance back
Space for fitting the door
On request

Dimensions in mm

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Track Application: NS
Normal track application
With double radius 245

ET

Clear passage height LDH

DH
DM

DM
HT

Without wicket door

RM

RM100

RM50

Wicket door without threshold rail

RM150

RM85

RM50

RM50

Wicket door with threshold

RM100

RM100

Wicket door without threshold rail

RM175

RM110

Note:
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
If using the spring buffer below the track, the clear height
under the track near the spring buffer is reduced by 70 mm.
Door weights for roof loads:
SPU F42/APU F42 Thermo/ALRF42Thermo
APU F42/ALR F42
ALR F42 Glazing

125

Observe min. sideroom, see page 58.

NS1
NS2

H
390
440

HT
330
380

Door height

INTERIOR

5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875
1500
2000
2250
2500
2750
3000
3250
3500
3750
4000
4250
4500
4750
5000
5250
5500
5750
6000
6250
6500
6750
7000
7250
7500
7750
8000

Range 1

RM

Range 2

200 [VL1, VL2 = 300]

= 320 N/m2
= 280 N/m2
= 560 N/m2

LZ

WE
140
160

BW
RM+310
RM+335

Track height

RM

Min. LH

Max. LH

5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

5190
5065
4940
4815
4690
4565
4440
4315
4190
4065
3940
3815
3690
3565
3440
3315
3190
3065
2940
2815
2690
2565
2440
2315
2190
2065

5810
5685
5560
5435
5310
5175
5030
4885
4730
4585
4440
4295
4150
4005
3860
3715
3570
3425
3280
3135
2990
2845
2700
2555
2410
2265

NS2

FFL

LZ

Without wicket door

NS1

LH

RM 200

RM = LDH

BW

HH

RM

Wicket door with threshold


LZ>5500

DE = LH + 250*

LH RM + 387

INTERIOR

125

WA 400**

LZ5500

DA

WE

Operator

Without operator

Note:
Observe the permissible size ranges of the door types
on pages1015 and 1829!
ALRF42 Vitraplan and ALRF42 Glazing on request
*
**
H
ET
DH
DM
DA
HT
L
BW
WE

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Min.
Or with chain hoist/pull rope
Min. headroom (see page39)
Min. distance back on request
Rear ceiling anchor on request
Central ceiling anchor on request
Min. distance to ceiling250
Obstruction depth
Anchor length=DELH15
(see page63)
Position of shaft support
Shaft centre from lintel

HH
DE
LH
LDH
LZ
RM
F

Obstruction height
Ceiling height
Track height
Clear passage height
Clear frame dimensions
(from 1200)
Grid height
Space for fitting the door
On request

Dimensions in mm

43

Track Application: GD
Normal track application
With inclination up to max. 27
and minimum high lift

ET
DH

Door weights for roof loads:


SPU F42/APU F42 Thermo/ALRF42Thermo = 320 N/m2
APU F42/ALR F42
= 280 N/m2
ALR F42 Glazing
= 560 N/m2

DM

Observe min. sideroom, see page 58.

DA

DM

WE

WE

140

GD 2

160
ET=min. distance back

250

GD 1+2

a
H

GD 1

Track inclined up to 27 to
determine degrees, see table

2RMLH+1120a6.5

For manual operation with long spring buffer

2RMLH+650a6.5

a>5 and with operator, with short spring buffer

2RMLH+880a6.5

a5 and with operator, with long spring buffer

2RMLH+270a6.5

For manual operation and shaft operator


with spring buffer below the track

45

Only to determine the roof slope


in degrees (a)

RM = LDH

INTERIOR

BW

DE

a
1
2
3
4
5
6
7
8
9
10
11
12
13
14

FFL

125

LZ

125

F
200 [VL1, VL2 = 300]

%
1.75
3.49
5.24
6.99
8.75
10.51
12.28
14.05
15.84
17.63
19.44
21.26
23.09
24.93

X(mm)
17.5
34.9
52.4
69.9
87.5
105.1
122.8
140.5
158.4
176.3
194.4
212.6
230.9
249.3

a
a
15
16
17
18
19
20
21
22
23
24
25
26
27

1000
%
26.79
28.67
30.57
32.49
34.43
36.40
38.39
40.40
42.45
44.52
46.63
48.77
50.95

INTERIOR

LZ

44

8000

7750

7500

7250

7000

6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

Max. 27

Max. 16

5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875
1500

Range 1

RM

Range 2

Notes:
The clearance required for fitting the door must be free of supply lines,
heater fans, etc.
If using the spring buffer below the track, the clear height
under the track near the spring buffer is reduced by 70 mm.
Observe the permissible size ranges of the door types
on pages1015 and 1829!
ALRF42 Vitraplan and ALRF42 Glazing on request

DH

DM
H
DA
DE
L
LDH
LZ
ET
RM
F

Rear ceiling anchor


GD1+GD2=2RMLH+645a6.5
(long spring buffer)
GD1+GD2=2RMLH+405a6.5
(short spring buffer)
GD1+GD2=2RMLH+405a6.5
(long spring buffer+operator)
Central ceiling anchor=see page63
Min. headroom (see page39)
Distance to ceiling on request
Ceiling height
Anchor length on request (see page63)
Clear passage height
Clear frame dimensions (from 1200)
Min. distance back
Grid height
Space for fitting the door
On request

Dimensions in mm

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

X
X(mm)
267.9
286.7
305.7
324.9
344.3
364.0
383.9
404.0
424.5
445.2
466.3
487.7
509.5

Track Application: L
Low headroom track application

ET

DM

DM

Door operation:
Manually operated: with rope or chain hoist
(recommended for manual operation!)
Power-driven: WA400 with chain box, ITO400 or SupraMaticH
*Clear passage height LDH

RM

RM 314

LDH = RM 50*

RM

Observe min. sideroom, see page58.

For distances greater than 500 mm,


an additional 12060 extrusion
is required

610

DE

Door weights for roof loads:


SPU F42/APU F42 Thermo/ALRF42Thermo = 320 N/m2
APU F42/ALR F42
= 280 N/m2
ALR F42 Glazing
= 560 N/m2

DA = 200

184

BF

Without
operator

Operator
WA 400**

WA300***

LZ5500

INTERIOR

FFL

Without wicket door

RM50

RM50

RM80

Wicket door with threshold

RM100

RM100

RM130

Wicket door without threshold rail

RM165

RM135

RM165

LZ>5500

LZ

125

125

RM100

RM100

RM130

RM100

RM100

RM130

Wicket door without threshold rail

RM195

RM165

RM195

** Or with chain hoist/pull rope


*** Track application with inclination not possible!

INTERIOR

Notes:
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
Observe the permissible size ranges of the door types
on pages1015 and 1829!
ALRF42 Vitraplan and ALRF42 Glazing on request

5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

LDH
RM
BF
DM

ET
H
DA
DE
L
LZ
F

Clear passage height


Grid height
Position of spring shaft=RM+682
Central ceiling anchor
Up to RM 3500=BF/2
From RM 3510=BF/3
Min. distance back = RM+990
Min. headroom 200 (see page39)
Distance to ceiling
Ceiling height
Anchor length=DERM15 (see page63)
Clear frame dimensions (from 1200)
Space for fitting the door
All door types available in any version.

LZ

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

7000

6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

All door types in any version on request.


1500

L1

RM

L2

200 [VL1, VL2 = 300]

Without wicket door


Wicket door with threshold

Dimensions in mm

45

Track Application: LD
Low headroom track application
With inclination

184
ET
BF

For distances greater than


500 mm, an additional
12060 extrusion is required

Door weights for roof loads:


SPU F42/APU F42 Thermo/ALRF42Thermo = 320 N/m2
APU F42/ALR F42
= 280 N/m2
ALR F42 Glazing
= 560 N/m2
Observe min. sideroom, see page58.
Only to determine the roof slope
in degrees (a)

DM
DA

a
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30

DM

45

RM 314

LDH = RM 50 *

INTERIOR

125

LZ

125

Max. 30

Max. 16

5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

LDH
RM
ET

H
BF
DM
DA
DE
L
LZ
F

Clear passage height


Grid height
Min. distance back
24=RM+990
616=RM+800
1830=RM+740
Min. headroom 200 (see page39)
Position of spring shaft on request
Central ceiling anchor on request
Distance to ceiling on request
Ceiling height
Anchor length on request (see page63)
Clear frame dimensions (from 1200)
Space for fitting the door

7000

6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

All door types in any version on request.


1500

46

X(mm)
34.9
69.9
105.1
140.5
176.3
212.6
249.3
286.7
324.9
364.0
404.0
445.2
487.7
531.7
577.4

All door types available in any version.

2000

LD2
RM
LD1

INTERIOR

LZ

Notes:
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
Observe the permissible size ranges of the door types
on pages1015 and 1829!
ALRF42 Vitraplan and ALRF42 Glazing on request

F
200 [VL1, VL2 = 300]

1000

* Notes:
Clear passage height LDH, see track application L
For door operation, see track application L

FFL

RM

DE

Track inclination from 2 to 30

%
3.49
6.99
10.51
14.05
17.63
21.26
24.93
28.67
32.49
36.40
40.40
44.52
48.77
53.17
57.74

Dimensions in mm

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Track Application: H
High-lift track application

Please note:
1. Select required track height according to the door height in table 1.
2. Determine the intersection of the door width and track height
using table 2.
3. Please check if, acc. to the explanations, a request is necessary.

ET
DH
DM

Note:
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
If using the spring buffer below the track, the clear height
under the track near the spring buffer is reduced by 70 mm.

250

WE

DA min.

DM

820

600

150

150

LZ
F

300

INTERIOR

H8

H 4+5

ET=min. distance back


2RMLH+1120

For manual operation with long spring buffer (standard)

2RMLH+670

For manual operation with spring buffer below the track

2RMLH+880

For shaft operator with long spring buffer (LHRM)1000

2RMLH+650

For shaft operator with short spring buffer (LHRM)>1000

2RMLH+430

For shaft operator with spring buffer below the track

2RMLH+950

All versions

2RMLH+430

For manual operation and shaft operator


with spring buffer below the track

Observe min. sideroom, see page58.

Table 2
Demarcation of track height for track application H

7700
7575
7450
7325
7200
7075
6950
6825
6700
6575
6450
6325
6185
5935
5685
5435
5185
4935
4685
4435
4185

Min. LH

Max. LH

7500
7375
7250
7125
7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125

7960
7835
7710
7585
7460
7335
7210
7085
6960
6835
6710
6585
6460
6335
6210
6085
5960
5835
5710
5585

10200
10200
10200
10200
10200
10200
10150
10025
9900
9775
9650
9525
9400
9275
9150
9025
8900
8775
8650
8525

Notes:
Observe the permissible size ranges of the door types
on pages1015 and 1829!
ALRF42 Vitraplan and ALRF42 Glazing on request
LDH
RM
LH
BW

Clear passage height


Grid height
Track height (see Table1+2)
Position of shaft support
H4+5=LH+280, H8=LH+305
DH
Rear ceiling anchor
H4+H5=2RMLH+645 (long spring buffer)
H4+H5=2RMLH+405 (long spring buffer +operator)
H8=2RMLH+485
DM
Central ceiling anchor (see page63)
WE
Shaft centre from lintel (see table1)
H
Min. headroom (see page39)
Min. DA H4=420
H5=450, 625 with double spring shaft
H8=490, 650 with double spring shaft
L
Anchor length DELH15 (see page63)
DE
Ceiling height
LZ
Clear frame dimensions (from 1200)
ET
Distance back
F
Space for fitting the door
All door types available in any version.

1500
2000
2250
2500
2750
3000
3250
3500
3750
4000
4250
4500
4750
5000
5250
5500
5750
6000
6250
6500
6750
7000
7250
7500
7750
8000

LH

10200

Max. LH
8300
8175
8050
7925
7800
7675
7550
7425
7185
6935
6685
6435
6185
5935
5685
5435
5185
4935
4685
4435
4185
3935
3685
3435
3185

Door
height
RM

H8, WE=205
All door types and versions available on request.

FFL

Min. LH
5460
5335
5210
5085
4960
4835
4710
4585
4460
4335
4210
4085
3960
3835
3710
3585
3460
3335
3210
3085
2960
2835
2710
2585
2460

H4, WE=160

LH

LH 310
F

RM = LDH

BW

DE

INTERIOR

Door
height
RM
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000

H5, WE=180

Table 1: Track heights (LH)

LZ

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

All door types available, versions with glazing A3, B3, M3, S3, R3, LB, P
and/or wicket door on request.
Door types APUF42S-Line, ALRF42S-Line, APUF42 and ALRF42 are possible;
APUF42Thermo, ALRF42Thermo and SPUF42 with thermo frames as well as
versions with glazing A3, B3, M3, S3, R3, LB, P and/or wicket door on request.
All door types in any version on request.
Dimensions in mm

47

Track Application: HA

High-lift track application


With high-mounted torsion spring shaft

Please note:
1. Select required track height according to the door height in table 3.
2. Determine the intersection of the door width and track height
using table 4.
3. Please check if, acc. to the explanations, a request is necessary.

ET
DH
DM

DM

750

DA

Note:
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
If using the spring buffer below the track, the clear height
under the track near the spring buffer is reduced by 70 mm.

250

WE

Door height
RM
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000

600

LH

RM = LDH

LH 310

BW

DE

INTERIOR

FFL

LZ

300

150

150

F
INTERIOR

HA 4

ET=min. distance back


2RMLH+1120

For manual operation with long spring buffer (standard)

2RMLH+670

For manual operation with spring buffer below the track

2RMLH+880

For shaft operator with long spring buffer (LHRM) 1000

2RMLH+650

For shaft operator with short spring buffer (LHRM) >1000

2RMLH+430

For shaft operator with spring buffer below the track

Observe the min. sideroom see page58.

6185
5935
5685
5435
5185
4935
4685
4435
4185

Max. LH
6185
5935
5685
5435
5185
4935
4685
4435
4185
3935
3685
3435
3185

Notes:
Observe the permissible size ranges of the door types
on pages1015 and 1829!
ALRF42 Vitraplan and ALRF42 Glazing on request
LDH
RM
LH
BW

DH

DM
WE
H
DA
L
DE
LZ
ET
F

Clear passage height


Grid height
Track height (see Table3+4)
Position of shaft support
Min.=HA4=LH+280
Max.(8120)=HA4=DE140
Rear ceiling anchor
HA4=2RMLH+645 (long spring buffer)
HA4=2RMLH+405 (short spring buffer)
HA4=2RMLH+405 (long spring buffer+operator)
Central ceiling anchor (see page63)
Shaft centre from lintel (see table3)
Min. headroom (see page39)
Distance to ceiling=HA4=min.420
Anchor length DELH15 (see page63)
Ceiling height
Clear frame dimensions (from 1200)
Distance back
Space for fitting the door
All door types available in any version.

1500
2000
2250
2500
2750
3000
3250
3500
3750
4000
4250
4500
4750
5000
5250
5500
5750
6000
6250
6500
6750
7000
7250
7500
7750
8000

LH

Table 4
Demarcation of track height for track applicationHA

Min. LH
3960
3835
3710
3585
3460
3335
3210
3085
2960
2835
2710
2585
2460

LZ

All door types available, versions with glazing A3, B3, M3, S3, R3, LB, P and/or
wicket door on request.
Door types APUF42S-Line, ALRF42S-Line, APUF42 und ALRF42 are possible;
APUF42Thermo, ALRF42Thermo und SPUF42 with thermo frames as well as
versions with glazing A3, B3, M3, S3, R3, LB, P and/or wicket door on request.
All door types in any version on request.
Dimensions in mm

48

HA4, WE=160

Table 3: Track heights (LH)

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Track Application: HD
High-lift track application
With inclination

ET
DH

Please note:
1. Select required track height according to the door height in table1
on page47.
2. Determine the intersection of the door width and track height
using table 5.
3. Please check if, acc. to the explanations, a request is necessary.

DM

250

DA

DM

ET=min. distance back

HD 4+5

HD 8

RM = LDH

LH

BW

For manual operation with long spring buffer (standard)

2RMLH+670a6.5

For manual operation with spring buffer below the track

2RMLH+880a6.5

For shaft operator with long spring buffer


(LHRM)1000and a5

2RMLH+650a6.5

For shaft operator with short spring buffer


(LHRM)>1000or a>5

2RMLH+430a6.5

For shaft operator with spring buffer below the track

2RMLH+950a6.5

All versions

2RMLH+430a6.5

For manual operation and shaft operator


with spring buffer below the track

See the high-lift track application with inclination for all other fitting dimensions.
Observe the min. sideroom, see page58.
Only to determine the roof slope
in degrees(a)

DE

INTERIOR

2RMLH+1120a6.5

FFL

LZ

150

a
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

150

300

F
INTERIOR

Notes:
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
If using the spring buffer below the track, the clear height
under the track near the spring buffer is reduced by 70 mm.
Observe the permissible size ranges of the door types
on pages1015 and 1829!
ALRF42 Vitraplan and ALRF42 Glazing on request
Table 5
Demarcation of track height for track application HD to 10,
Track application HD 11 to 30 on request!

DA
L
LH
H
BW
DH

DM
WE
DE
LDH
LZ
ET
RM
F

7700
7575
7450
7325
7200
7075
6950
6825
6700
6575
6450
6325
6185
5935
5685
5435
5185
4935
4685
4435
4185
3935
3685
3435
3185

X(mm)
17.5
34.9
52.4
69.9
87.5
105.1
122.8
140.5
158.4
176.3
194.4
212.6
230.9
249.3
267.9

a
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

1000
%
28.67
30.57
32.49
34.43
36.40
38.39
40.40
42.45
44.52
46.63
48.77
50.95
53.17
55.43
57.74

X
X(mm)
286.7
305.7
324.9
344.3
364.0
383.9
404.0
424.5
445.2
466.3
487.7
509.5
531.7
554.3
577.4

Distance to ceiling on request


Anchor length DEL+140 (see page63)
Track height (see Table 1 on page47 and Table5)
Min. headroom (see page39)
Position of shaft support
HD4+5=LH+280, HD8 =LH+305
Rear ceiling anchor
HD4+HD5=2RMLH+645a6.5 (long spring buffer)
HD4+HD5=2RMLH+405a6.5 (short spring buffer)
HD4+HD5=2RMLH+405a6.5 (long spring buffer+operator)
HD8=2RMLH+485
Central ceiling anchor on request
Shaft centre from lintel (see Table1 on page47)
Ceiling height
Clear passage height
Clear frame dimensions (from 1200)
Distance back
Grid height
Space for fitting the door
All door types available in any version.
All door types available, versions with glazing A3, B3, M3, S3, R3, LB, P
and/or wicket door on request.
Door types APUF42S-Line, ALRF42S-Line, APUF42 und ALRF42 are possible;
APUF42Thermo, ALRF42Thermo und SPUF42 with thermo frames as well as
versions with glazing A3, B3, M3, S3, R3, LB, P and/or wicket door on request.
All door types in any version on request.

Dimensions in mm

1500
2000
2250
2500
2750
3000
3250
3500
3750
4000
4250
4500
4750
5000
5250
5500
5750
6000
6250
6500
6750
7000
7250
7500
7750
8000

LH

10200

%
1.75
3.49
5.24
6.99
8.75
10.51
12.28
14.05
15.84
17.63
19.44
21.26
23.09
24.93
26.79

LZ

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

49

Track Application: HG
High-lift track application
With steep track
(Application for loading ramp doors)

Please note:
1. Select required track height according to the door height in table 6.
2. Determine the intersection of the door width and track height
using table 7.
3. Please check if, acc. to the explanations, a request is necessary.
Notes:
Door types APUF42S-Line/ALRF42S-Line/ALRF42 Glazing,
doors with real glass infill and wicket doors are not possible!
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
If using the spring buffer below the track, the clear height
under the track near the spring buffer is reduced by 70 mm.
INTERIOR

Table 6: Track heights (LH)


Door height
RM
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375

FFL

150

150

LZ
F
INTERIOR

SB 120

HG 4+5

ET=min. distance back


2RMLH+1120

For manual operation with long spring buffer (standard)

2RMLH+670

For manual operation with spring buffer below the track

2RMLH+880

For shaft operator with long spring buffer (LHRM)1000

2RMLH+650

For shaft operator with short spring buffer (LHRM)>1000

2RMLH+430

For shaft operator with spring buffer below the track

HG5, WE=180

HG4, WE=160

LDH
RM
LH
DH

Clear passage height


Grid height
Track height (see Table6)
Rear ceiling anchor =
HG4+HG5=2RMLH+645 (long spring buffer)
HG4+HG5=2RMLH+405 (short spring buffer)
HG4+HG5=2RMLH+405 (long spring buffer+operator)
DM
Central ceiling anchor (see page63)
WE
Shaft centre from lintel (see table6)
H
Min. headroom (see page39)
Min. DA HG4=420
HG5=450, 625 with double spring shaft
SB
Slot width
L
Anchor length DELH15 (see page63)
ET
Distance back
DE
Ceiling height
LZ
Clear frame dimensions (from 1200)
F
Space for fitting the door

Table 7
Demarcation of track height for track application HG
8300

7700
7575
7450
7325
7200
7075
6950
6825
6700
6575
6450
6325
6185
5935
5685
5435
5185
4935
4685
4435
4185

All door types available in any version.

LZ

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

All door types available, versions with glazing A3, B3, M3, S3, R3, LB, P on request.

1500

LH

Max. LH
8300
8175
8050
7925
7800
7675
7550
7425
7185
6935
6685
6435
6185
5935
5685
5435
5185
4935
4685
4435
4185
3935

Notes:
Observe the permissible size ranges of the door types
on pages1015 and 1829!
ALRF42 Vitraplan on request

Other versions on request.


Observe min. sideroom, see page58.

50

Min. LH
5460
5335
5210
5085
4960
4835
4710
4585
4460
4335
4210
4085
3960
3835
3710
3585
3460
3335
3210
3085
2960
2835

Door types APUF42S-Line, ALRF42S-Line, APUF42 and ALRF42 are possible;


APUF42Thermo, ALRF42Thermo and SPUF42 with thermo frames as well
as versions with glazing A3, B3, M3, S3, R3, LB, P must be requested.
All door types in any version on request.
Dimensions in mm

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Track Application: HU

High-lift track application


With low-mounted torsion spring shaft

Please note:
1. Select required track height according to the door height in table 6.
2. Determine the intersection of the door width and track height
using table 7.
3. Please check if, acc. to the explanations, a request is necessary.

ET
DH
DA

DM

Note:
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
If using the spring buffer below the track, the clear height
under the track near the spring buffer is reduced by 70 mm.

850

DM

INTERIOR

850

150

150

LZ
F

300

INTERIOR

HU 4+5

ET=min. distance back


2RMLH+1120

For manual operation with long spring buffer (standard)

2RMLH+670

For manual operation with spring buffer below the track

2RMLH+650

For shaft operator with short spring buffer=(LHRM1510)

2RMLH+430

For shaft operator with spring buffer below the track

Notes:
Observe the permissible size ranges of the door types
on pages1015 and 1829!
ALRF42 Vitraplan and ALRF42 Glazing on request

Other versions on request.


Observe min. sideroom, see page58.

Table 7
Demarcation of track height for track applicationHU

DE
LDH
RM
LH
DH

8300

7700
7575
7450
7325
7200
7075
6950
6825
6700
6575
6450
6325
6185
5935
5685
5435
5185
4935
4685
4435
4185
3935

DM
WE
H
DA
L
LZ
ET
F

Ceiling height
Clear passage height
Grid height
Track height (see Table6)
Rear ceiling anchor
HU4+HU5=2RMLH+645 (long spring buffer)
HU4+HU5=2RMLH+405 (short spring buffer)
HU4+HU5=2RMLH+405 (long spring buffer+operator)
Central ceiling anchor (see page63)
Shaft centre from lintel (see table6)
Min. headroom (see page39)
Min. distance to ceiling250
Anchor length DELH15 (see page63)
Clear frame dimensions (from 1200)
Distance back
Space for fitting the door

7000

6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

All door types available in any version.

1500

LH

Max. LH
8300
8175
8050
7925
7800
7675
7550
7425
7185
6935
6685
6435
6185
5935
5685
5435
5185
4935
4685
4435
4185
3935

HU5, WE=335

FFL

Min. LH
6510
6385
6260
6135
6010
5885
5760
5635
5510
5385
5260
5135
5010
4885
4760
4635
4510
4385
4260
4135
4010
3885

HU4, WE=315

Door height
RM
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375

LH

RM = LDH

RM + 400

DE

LH 310

Table 6: Track heights (LH)

LZ

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

All door types available, versions with glazing A3, B3, M3, S3, R3, LB, P
and/or wicket door on request.
Door types APUF42S-Line, ALRF42S-Line, APUF42 and ALRF42 are possible;
APUF42Thermo, ALRF42Thermo and SPUF42 with thermo frames as well as
versions with glazing A3, B3, M3, S3, R3, LB, P and/or wicket door on request.
All door types in any version on request.
Dimensions in mm

51

Track Application: RD

High-lift track application


With low-mounted torsion spring shaft and inclination

Please note:
1. Select required track height according to the door height in table6
on page51.
2. Determine the intersection of the door width and track height
using table 8.
3. Please check if, acc. to the explanations, a request is necessary.

ET
DH

DM
DA

DM

Note:
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
If using the spring buffer below the track, the clear height
under the track near the spring buffer is reduced by 70 mm.

850

track inclination up to 30

ET=min. distance back

RD 4+5

RM = LDH

RM + 400

LH

DE

850

INTERIOR

2RMLH+1160a6.5

For manual operation with long spring buffer (standard)

2RMLH+670a6.5

For manual operation with spring buffer below the track

2RMLH+920a6.5

For shaft operator with long spring buffer=a5

2RMLH+690a6.5

For shaft operator with long spring buffer


=(LHRM)1510or a>5

2RMLH+430a6.5

For shaft operator with spring buffer below the track

See the high-lift track application with inclination for all other fitting dimensions.
Observe min. sideroom, see page58.

FFL

150

Only to determine the roof slope


in degrees(a)
a
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

150

LZ
F

300

INTERIOR

Notes:
Observe the permissible size ranges of the door types on
pages1015 and 1829!
ALRF42 Vitraplan and ALRF42 Glazing on request
Table 8
Demarcation of track height for track application RD to 10,
Track application RD 11 to 30 on request!

DE
L
LH
H
DH

7700
7575
7450
7325
7200
7075
6950
6825
6700
6575
6450
6325
6185
5935
5685
5435
5185
4935
4685
4435
4185
3935
3685
3435
3185

DM
WE
DA
LDH
LZ
RM
F

X(mm)
17.5
34.9
52.4
69.9
87.5
105.1
122.8
140.5
158.4
176.3
194.4
212.6
230.9
249.3
267.9

a
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

1000
%
28.67
30.57
32.49
34.43
36.40
38.39
40.40
42.45
44.52
46.63
48.77
50.95
53.17
55.43
57.74

X(mm)
286.7
305.7
324.9
344.3
364.0
383.9
404.0
424.5
445.2
466.3
487.7
509.5
531.7
554.3
577.4

Ceiling height
Anchor length DEL15 (see page63)
Track height (see Table6 on page51)
Min. headroom (see page39)
Rear ceiling anchor =
RD4+RD5=2RMLH+645a6.5 (long spring buffer)
RD4+RD5=2RMLH+405a6.5 (short spring buffer)
RD4+RD5=2RMLH+405a6.5 (long spring buffer+operator)
Central ceiling anchor (see page63)
Shaft centre from lintel (see Table6 on page51)
Distance to ceiling on request
Clear passage height
Clear frame dimensions (from 1200)
Grid height
Space for fitting the door

7000

6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

All door types available, versions with glazing A3, B3, M3, S3, R3, LB, P
and/or wicket door on request.
Door types APUF42S-Line, ALRF42S-Line, APUF42 and ALRF42 are possible;
APUF42Thermo, ALRF42Thermo and SPUF42 with thermo frames as well as
versions with glazing A3, B3, M3, S3, R3, LB, P and/or wicket door on request.
All door types in any version on request.
Dimensions in mm

LZ

52

All door types available in any version.

1500

LH

8300

%
1.75
3.49
5.24
6.99
8.75
10.51
12.28
14.05
15.84
17.63
19.44
21.26
23.09
24.93
26.79

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Track Application: RG

High-lift track application


With low-mounted torsion spring shaft and steep track
(Application for loading ramp doors)

Please note:
1. Select required track height according to the door height in table 9.
2. Determine the intersection of the door width and track height
using table 10.
3. Please check if, acc. to the explanations, a request is necessary.

ET
DH
DA

DM

Notes:
Door types APUF42S-Line/ALRF42S-Line and wicket doors
are not possible!
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
If using the spring buffer below the track, the clear height
under the track near the spring buffer is reduced by 70 mm.

850

DM

Table 9: Track heights (LH)

LH

LH 310

INTERIOR

RM = LDH

RM + 400

DE

850

Door height
RM
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375

FFL

150

150

LZ
F
INTERIOR

SB 120

RG 4+5

ET=min. distance back


2RMLH+1120

For manual operation with long spring buffer (standard)

2RMLH+670

For manual operation with spring buffer below the track

2RMLH+650

For shaft operator with short spring buffer=(LHRM1510)

2RMLH+430

For shaft operator with spring buffer below the track

Max. LH
8300
8175
8050
7925
7800
7675
7550
7425
7185
6935
6685
6435
6185
5935
5685
5435
5185
4935
4685
4435
4185
3935

RG5, WE=276

RG4, WE=246

Notes:
Observe the permissible size ranges of the door types
on pages1015 and 1829!
ALRF42 Vitraplan and ALRF42 Glazing on request

Other versions on request.


Observe min. sideroom, see page58.

Table 10
Demarcation of track height for track applicationRG

LDH
RM
LH
DH

8300

7700
7575
7450
7325
7200
7075
6950
6825
6700
6575
6450
6325
6185
5935
5685
5435
5185
4935
4685
4435
4185

DM
WE
H
DA
SB
L
ET
DE
LZ
F

Clear passage height


Grid height
Track height (see Table9)
Rear ceiling anchor =
RG4+RG5=2RMLH+580 (long spring buffer)
RG4+RG5=2RMLH+340 (short spring buffer)
RG4+RG5=2RMLH+340 (long spring buffer+WA400)
Central ceiling anchor (see page63)
Shaft centre from lintel (see table9)
Min. headroom (see page39)
Min. distance to ceiling250
Slot width
Anchor length DELH15 (see page63)
Distance back
Ceiling height
Clear frame dimensions (from 1200)
Space for fitting the door
All door types available in any version.

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

All door types available, versions with glazing A3, B3, M3, S3, R3, LB, P on request.
1500

LH

Min. LH
6510
6385
6260
6135
6010
5885
5760
5635
5510
5385
5260
5135
5010
4885
4760
4635
4510
4385
4260
4135
4010
3885

LZ

Door types APUF42S-Line, ALRF42S-Line, APUF42 and ALRF42 are possible;


APUF42Thermo, ALRF42Thermo and SPUF42 with thermo frames as well
as versions with glazing A3, B3, M3, S3, R3, LB, P must be requested.
All door types in any version on request.
Dimensions in mm

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

53

Track Application: V
Vertical track application

Notes:
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
Observe the permissible size ranges of the door types
on pages1015 and 1829!

820
WE

500

Observe min. sideroom, see page58.

LDH
RM
WE

DE

BW

H
DE

BW

INTERIOR

RM = LDH

LZ
F

Clear passage height


Grid height
Shaft centre from lintel
V6=160, V7=180
Min. headroom (see page39)
Ceiling height
2RM+500 (V6)
2RM+540 (V7)
2RM+730 (V7 with double spring shaft)
2RM+635 (V9)
2RM+780 (V9 with double spring shaft)
Position of shaft support
2RM+360 (V6)
2RM+385 (V7)
2RM+435 (V9)
Clear frame dimensions (from 1200)
Space for fitting the door

FFL

125

125

LZ
F
INTERIOR

Note:
ALRF42 Vitraplan and ALRF42
Glazing on request

7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

LZ

54

8000

7750

7500

7250

7000

6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

1500

All door types available in any version.

2000

RM

V6

V7

V9

220 [VL1, VL2 = 300]

All door types available, versions


with glazing A3, B3, M3, S3, R3, LB, P
and/or wicket door on request.
Door types APUF42S-Line, ALRF42S-Line,
APUF42 and ALRF42 are possible;
APUF42Thermo, ALRF42Thermo and
SPUF42 with thermo frames as well as
versions with glazing A3, B3, M3, S3, R3,
LB, P and/or wicket door on request.
All door types in any version on request.
Dimensions in mm

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Track Application: VA

Vertical track application


With high-mounted torsion spring shaft

Notes:
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
Observe the permissible size ranges of the door types
on pages1015 and 1829!

820
WE

500

Observe min. sideroom, see page58.

LDH
RM
WE
H
DE

DE

BW

BW

LZ
F

Clear passage height


Grid height
Shaft centre from lintel
VA 6=160
Min. headroom (see page39)
Ceiling height
Min.: 2RM+510 (VA6)
Max.: depends on order
Position of shaft support =
Min.: 2RM+370 (VA6)
Max.: 7895=DE140
Clear frame dimensions (from 1200)
Space for fitting the door

RM = LDH

INTERIOR

FFL

LZ

125

125

F
INTERIOR

Note:
ALRF42 Vitraplan and ALRF42
Glazing on request

5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

LZ

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

8000

7750

7500

7250

7000

6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

All door types available in any version.

1500

VA6

RM

220 [VL1, VL2 = 300]

All door types available, versions


with glazing A3, B3, M3, S3, R3, LB, P
and/or wicket door on request.
All door types in any version on request.
Dimensions in mm

55

Track Application: VU

Vertical track application


With low-mounted torsion spring shaft

Notes:
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
Observe the permissible size ranges of the door types
on pages1015 and 1829!
H

Observe min. sideroom, see page58.

WE
DE
WE

850

INTERIOR

850

RM = LDH

RM + 400

DE

H
LDH
RM
LZ
F

Ceiling height=2RM+350
Shaft centre from lintel
VU 6=315
VU 7=335
VU 9=375
Min. headroom (see page39)
Clear passage height
Grid height
Clear frame dimensions (from 1200)
Space for fitting the door

FFL

LZ

125

125

F
INTERIOR

Note:
ALRF42 Vitraplan and ALRF42
Glazing on request

7000
6875
6750
6625
6500
6375
6250
6125
6000
5875
5750
5625
5500
5375
5250
5125
5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

LZ

56

8000

7750

7500

7250

7000

6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

1500

All door types available in any version.

2000

RM

VU6

VU7

VU9

220 [VL1, VL2 = 300]

All door types available, versions


with glazing A3, B3, M3, S3, R3, LB, P
and/or wicket door on request.
Door types APUF42S-Line, ALRF42S-Line,
APUF42 and ALRF42 are possible;
APUF42Thermo, ALRF42Thermo and
SPUF42 with thermo frames as well as
versions with glazing A3, B3, M3, S3, R3,
LB, P and/or wicket door on request.
All door types in any version on request.
Dimensions in mm

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Track Application: WG

Vertical track application


With low-mounted torsion spring shaft and steep track
(Application for loading ramp doors)

Notes:
Door types APUF42S-Line/ALRF42S-Line and wicket doors
are not possible!
The clearance required for fitting the door must be free
of supply lines, heater fans, etc.
Observe the permissible size ranges of the door types
on pages1015 and 1829!

WE

Observe min. sideroom, see page58.

850

INTERIOR
DE
WE

850

RM = LDH

RM + 400

DE

H
SB
LDH
RM
LZ
F

Ceiling height =2RM+350


Shaft centre from lintel
WG6=246
WG7=276
Min. headroom (see page39)
Slot width
Clear passage height
Grid height
Clear frame dimensions (from 1200)
Space for fitting the door

FFL

LZ

125

125

F
INTERIOR

Note:
ALRF42 Vitraplan and ALRF42
Glazing on request

5000
4875
4750
4625
4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

LZ

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

8000

7750

7500

7250

7000

6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

All door types available in any version.

1500

WG6

RM

WG7

SB 120

All door types available, versions


with glazing A3, B3, M3, S3, R3, LB, P
on request.
Door types APUF42S-Line, ALRF42S-Line,
APUF42 and ALRF42 are possible;
APUF42Thermo, ALRF42Thermo and
SPUF42 with thermo frames as well as
versions with glazing A3, B3, M3, S3, R3,
LB, P must be requested.
All door types in any version on request.
Dimensions in mm

57

Sideroom

Required sideroom
Track application/designation
N, NA, ND, NH, NS, GD, V, VA, VU, WG
H, HA, HD, HG, HU, RD, RG
L, LD

S
125
150
125

Track application/designation
N, NA, ND, NH, NS, GD
Hand pulley
H, HA, HD, HG, HU, RD, RG
V, VA, VU, WG
Chain hoist
Shaft operators

S
140
150
125
Page61
Page6470

Sideroom
ThermoFrame version

INTERIOR

INTERIOR
Sideroom with frame covering
ThermoFrame version
70

ThermoFrame version

34
LZ - 15

INTERIOR

ASA
ASW
BO

58

Screw-on anchor 7040


Screw-on bracket 70120/170
Hole

BS
LZ
R

Self-tapping screw
Clear frame dimensions
Box section

S
TB

Sideroom
Door leaf

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Lintel Fitting

Single-skinned steel fascia for SPUF42


to make up for insufficient headroom up to
125mm (only for track applications N and L)

Normal lintel fitting


Double spring shaft

60

60

TB

RM

TB

Lintel fitting with ThermoFrame

RM

TB

RM

TB

INTERIOR

RM

LF

LF

60

60

190

TB

PU fascia panel to make up for insufficient


headroom from 100mm
Aluminium fascia profile to make
up for insufficient headroom (see table)

Smooth panel, anodised, for APUF42,


ALRF42, ALRF42Glazing, ALRF42Vitraplan
to make up for insufficient headroom
from 31to 190mm
(only for track applications N and L)

INTERIOR

INTERIOR

RM

INTERIOR

LAB 100
RAB 200

RM

30

60

30

125

Normal lintel fitting


Lintel variation up to 30 mm high

TB

INTERIOR

Aluminium frame fascia panel


Height
Infill type
200
FU, LB, S, SE, XU, FK, KR
245
S2, S3, R2, R3, C2, A2, A3, B2,
B3, M2, M3
230692 S2, S3, R2, R3, C2, A2, A3, B2,
B3, M2, M3 for APUF42S-Line/
ALRF42 S-Line

H
RM
TB
LF
LAB
RAB

Min. headroom (see page39)


Grid
Door leaf
Structural opening
Fascia panel
Frame fascia panel

Aluminium frame fascia panel with real glass


infill VG,E2andG2 on request.

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

59

Bottom Edge

Without wicket door/with wicket door and threshold rail

With wicket door with trip-free threshold

RM

INTERIOR

INTERIOR

13

45

INTERIOR

RM

RM

INTERIOR

45

1200

INTERIOR

10

INTERIOR

EW
RM

60

EW

10

EW

Drainage
Grid

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Chain Hoist

Track applications N, NA, ND, NH, NS, GD, H, HA, HD, HG, HU, RD, RG, VU, WG

215

Track application
S

N
165

NA
165

ND
165

NH
165

NS
165

GD
165

H
185

HA
185

HD
185

HG
185

HU
185

RD
185

RG
185

VU
165

WG
165

Track applications L and LD

390

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

165

61

Hand Pulley

With rope or link steel chain

Track applications up to 20m door surface


With rope or link steel chain

N, NA, ND, NH, NS, GD, H, HA, HD, HG, HU, RD, RG

410

With rope or link steel chain

N, NA, ND, NH, NS, GD: 140


H, HA, HD, HG, HU, RD, RG: 150

V, VA

125

270

With rope or link steel chain

340

62

VU, WG

125

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Ceiling Anchors

Track suspensions for all track applications except V, VA, VU and WG


Track suspensions as ceiling anchors in five lengths, standard length 469mm.
DH=Rear ceiling anchor (see pages3953), door weights for roof loads (see pages3946).
DH
DM

DM

Double track (suspensions),


Door heights RM5000
DH
M
H
1555

1
15603720
1
1
37305195
2
1

DM

DH/2
DH/3

BF
DM

DM

Double track (suspensions), L


BF
M
DM
4182
1
BF/2
>4182
2
BF/3

DH
DM

DM

C 45

L = 1500* 2500**

C 45

L = 1146* 1499**

C 45

L = 834* 1145**

C 45

L = 470* 833**

L 469

C-rail (suspensions) all track sizes,


Door heights RM>5000
DH
M
H
DM
1
1
DH/2

C 45
L 55 x 29

* Min.
** Max.

BF
DH
DM
L

Position of spring shaft


Rear ceiling anchor
Centre ceiling anchor
Anchor length=DERM125 (see page39)

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

63

Shaft Operator WA 300

Shaft operator WA300 for track applications N, NA, H, HA, HG, V and VA
As shown in the figure, the operator can be fitted either left or right, viewed from the inside.
Fitting example right

Fitting example right

Shaft operator WA300 for track application L


As shown in the figure, the operator can be fitted either left or right, viewed from the inside.
In fitting example9: on the side opposite the door lock.
Fitting example right

Fitting example right

Shaft operator WA300 for track applications HU, RG, VU and WG


As shown in the figure, the operator can be fitted either left or right, viewed from the inside.
Fitting example right

In the door range LZ3000 and RM3500


a sideroom from 200 is possible

Fitting example right

**
LZ
BW

64

In the door range LZ3000 and RM3500 the


track applications VU and HU are not possible
Clear frame dimensions
Position of shaft support

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Shaft Operator WA 300

Shaft operator WA300 for track applications N, NA and L


With wicket door

4500

4750

5000

5250

5500

5750

4750

5000

5250

5500

5750

6000

4250

4500

4000

4250

LZ

3750

3500

3250

3000

2750

2500

2250

2000

1750

4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

RM

4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875
1200

RM

Without wicket door

LZ

Shaft operator WA 300 for track applications H, HA, HG, HU, RG, V, VA, VU and WG
With wicket door

LZ

6000

4000

3750

3500

3250

3000

2750

2500

2250

2000

4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875
1750

6000

5750

5500

5250

5000

4750

4500

4250

4000

3750

3500

3250

3000

2750

2500

2250

2000

RM

4500
4375
4250
4125
4000
3875
3750
3625
3500
3375
3250
3125
3000
2875
2750
2625
2500
2375
2250
2125
2000
1875
1200

RM

Without wicket door

LZ

WA300 possible.
WA300 possible, versions with glazing A3, B3, M3, S3, R3, LB andP on request.
WA300 on request.

LZ
RM

Clear frame dimensions


Grid height

Dimensions in mm

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

65

Shaft Operator WA 400


As a frame-mounted operator

Shaft operator WA 400 for all track applications, except for L, LD, HU, RD, RG, VU and WG

BW

400

As shown in the figure, the operator can be fitted either left or right, viewed from the inside.

575

LZ

N: 280*
H: 300*
V : 280*

380

LZ

N: 280*
H: 300*
V : 280*

* Note:
Dimension+75mm if using a non-jointed emergency crank handle
Shaft operator WA 400 for track applications HU, RD, RG, VU and WG

**

400

As shown in the figure, the operator can be fitted either left or right, viewed from the inside.

700

LZ

HU,RD,RG:
290*
VU,WG:
270*

550

LZ

HU,RD,RG:
290*
VU,WG:
270*

* Note:
Dimension+75mm if using a non-jointed emergency crank handle
** On request

LZ
BW

66

Clear frame dimensions


Position of shaft support

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Shaft Operator WA 400


With chain box

Shaft operator WA 400 for all track applications, except for L, LD, HU, RD, RG, VU and WG
As shown in the figure, the operator can be fitted either left or right, viewed from the inside.
In fitting example5: on the side opposite the door lock.

950

910

BW

Fitting example right

BW

Fitting example right

590

N: 200**
H: 220**
V : 200**

LZ

N: 330*
H: 340*
V : 330*

LZ

375

Shaft operator WA 400 for the track applications L and LD


As shown in the figure, the operator can be fitted either left or right, viewed from the inside.
In fitting example5: on the side opposite the door lock.
Fitting example right

1000

950

200

200

Fitting example right

545

LZ

200**

LZ

335

310*

Shaft operator WA 400 for track applications HU, RD, RG, VU and WG
As shown in the figure, the operator can be fitted either left or right, viewed from the inside.
In fitting example5: on the side opposite the door lock.
Fitting example right

545

On request

On request

950

950

Fitting example right

LZ

HU,RD,RG: 220**
VU,WG: 200**

* Note:
Dimension+75mm if using a non-jointed emergency crank handle
LZ

Clear frame dimensions

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

545

LZ

VU6,WG6: HU,RD,RG: 330**


320**
VU,WG: 320**

** Note:
Dimension+40mm if using a non-jointed emergency crank handle
BW

Position of shaft support

67

Shaft Operator WA 400


For central mounting

Shaft operator WA 400 for track applications N and ND


Control A/B 445, 460

Control B 460 FU

500

500

H min.

N1

520

45

590

45

N2

550

50

615

45

675
(810)

45

ND1

520

65

550

48

ND2

550

75

570

48

650
(810)

48

N3
(RM>7000)

RM

B460FU

F min.

ND3
(RM>7000)

F min.

A/B445, 460
H min.

RM

Track
application

Shaft operator WA 400 for the track applications NH and GD


Control A/B 445, 460

Control B 460 FU

500

Track
application

DA min.

F min.

DA min.

B460FU

NH1/GD1

415

50

480

45

NH2/GD2

440

50

485

45

NH3

565

45

F min.

LH

A/B445, 460

RM

RM

LH

DA

DA

500

Shaft operator WA 400 for track application NS


Control A/B 445, 460

Control B 460 FU

500

500

435

RM

RM

435

Track application

A/B445, 460

B460FU

H min.

F min.

H min.

F min.

NS1

570

20

615

45

NS2

600

25

640

45

Note:
WA 400 as a centre motor in conjunction with double spring shaft on request!
H
RM

68

Headroom
Grid height

DA
LH

Distance to ceiling
Track height

Clearance ceiling/shaft operator

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Shaft Operator WA 400


For central mounting

Shaft operator WA 400 for track applications H, HG and HD


Control A/B 445, 460

Control B 460 FU
530

DA

DA

530

B460FU

F min.

DA min.

F min.

H4, HG4

500

55

540

45

H5, HG5

500

55

540

45

565

45

H8
HD

LH

A/B445, 460
DA min.

RM

RM

LH

Track
application

On request

Shaft operator WA 400 for the track applications HU, RD and RG

975
620

RM

RM

300

400

400

580
300

1510

1760
725

975

1510

1760
725

250

Control B 460 FU

250

Control A/B 445, 460

Note:
WA 400 as a centre motor in conjunction with double spring shaft on request!
RM
DA

Grid height
Distance to ceiling

LH
F

Track height
Clearance ceiling/shaft operator

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

69

Shaft Operator WA 400


For central mounting

Shaft operator WA 400 for track application V


Control A/B 445, 460

Control B 460 FU

800

500

V6: 2 x RM + 500
V7: 2 x RM + 540
V9: 2 x RM + 635

V6: 2 x RM + 500
V7: 2 x RM + 540

500

800

220

220

Shaft operator WA 400 for track applications VU and WG

400

725
RM

RM

400

725

1000

Control B 460 FU

1000

Control A/B 445, 460

220

220
580

580

Note:
WA 400 as a centre motor in conjunction with double spring shaft on request!
RM
DA

70

Grid height
Distance to ceiling

LH

Track height

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Chain Drive Operator ITO400

ITO 400track applications N and ND (doors with wicket doors on request)


W
S
V

245
230

N1 = 300
N2 = 325

160

RM 200

RM

260

60

N1: H 390
N2: H 440

1000

Track applicationsN1, N2, ND1 and ND2

200
610

Boom length for door height up to 2500

3500

3445

3850

Boom length for door height up to 3500

4500

4445

4850

Boom length for door height up to 4500

5500

5445

5850

Special length boom for N1 and ND1 on request

RM+722

RM+667

RM+1072

Special length boom for N2 and ND2 on request

RM+829

RM+774

RM+1179

ITO400 track applications L and LD (doors with wicket doors on request)


W
S
V

245
230

170

160

RM 315

RM

265

60

260

1000

200
610

Track applications L and LD

Boom length for door height up to 2500

3500

3445

3850

Boom length for door height up to 3500

4500

4445

4850

Boom length for door height up to 4500

5500

5445

5850

RM+955

RM+900

RM+1305

Special length boom on request

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

71

Operator SupraMaticHT

SupraMatic HT track application N (doors with wicket door, ALRF42Glazing and doors with real glass infill on request)*
W
S

120

30

300

300

RM 200

RM

260

60

390

75

200
610

Track applicationN1

Boom lengthK

2975

3200

Boom lengthM

3225

3450

Boom lengthL

3900

4125

Boom lengthXL

4150

4375

SupraMatic HT track application L (doors with wicket door, ALRF42Glazing and doors with real glass infill on request)*
W
S

120

30

300

RM 315

RM

265

60

170

260

75

200
610

Track applicationL1

Boom lengthM

3225

3450

Boom lengthL

3900

4125

Boom lengthXL

4150

4375

(See the next page for the size range for SupraMatic HT)

* Note:
Operator not possible for doors with a depth of 67mm!
RM

72

Grid height

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Operator SupraMaticHT

SupraMatic HT size range


No. of door sections

Track applicationL1

375

500

625**

3000

XL

2875

XL

2750

2625

2500

2375

4*

2250

750**

7000

6750

6500

6250

6000

5750

5500

5250

5000

4750

4500

K
4250

1875
4000

3750

3500

3250

3000

2750

M
M

2500

K
K

2250

2125
2000

2000

RM

Boom length
Track applicationN1

LZ

SupraMatic HT not possible.


SupraMatic HT possible.
SupraMatic HT on request.

LZ
RM
*
**

Clear frame dimensions


Grid height
Top door section 500mm
Only without wicket door

Dimensions in mm

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

73

Door Leaf Speeds

Door leaf speeds WA 300/WA400


(ATTENTION! The stated speeds can only be achieved under optimum conditions regarding door size and track size. More detailed information on request, as it is dependent on door
heights and track heights.)

WA 400

Max. speed in
mm/s, open/close
[5]

Max. speed in
mm/s, open/close
[6]

rpm [1]

Max. speed in
mm/s, open/close

rpm [1]

Max. speed in
mm/s, open/close

rpm [1]

Max. speed in
mm/s, open/close

rpm [1]

Max. speed in
mm/s, open/close

Frame-mounted operator [1]

Chain box operator [1]

Max. speed in
mm/s, open/close

Max. speed in
mm/s, open/close

Max. speed in
mm/s, open/close

Max. speed in
mm/s, open/close

With
twin roller

Fitting

Without
twin roller

Control B 460 FU
Without
twin roller

Control A/B445 and 460

With
twin roller

WA300S4
Integrated/
external control 360

N1

190

95

30

190

30

190

30

190

30

190

Yes

Yes

300/200

375/200

300/300

375/300 (375)

N2

210

105

24

210

30

265

24

210

30

265

Yes

Yes

300/200

450/200

300/300

450/300 (450)

N3

16

190

24

290

Yes

Yes

300/200

450/200

300/300

450/300 (450)

NA1

190

95

30

190

30

190

30

190

30

190

Yes

Yes

300/200

375/200

300/300

375/300 (375)

NA2

210

105

24

210

30

265

24

210

30

265

Yes

Yes

300/200

450/200

300/300

450/300 (450)

ND1

30

190

30

190

30

190

30

190

Yes

Yes

300/200

375/200

300/300

375/300 (375)

ND2

24

210

30

265

24

210

30

265

Yes

Yes

300/200

450/200

300/300

450/300 (450)

ND3

16

190

24

290

Yes

Yes

300/200

450/200

300/300

450/300 (450)

NH1

30

190

30

190

30

190

30

190

Yes

Yes

300/200

375/200

300/300

375/300 (375)

NH2

24

210

30

265

24

210

30

265

Yes

Yes

300/200

450/200

300/300

450/300 (450)

NH3

16

190

24

290

Yes

Yes

300/200

450/200

300/300

450/300 (450)

NS1

30

190

30

190

30

190

30

190

Yes

Yes

300/200

375/200

300/300

375/300 (375)

NS2

24

210

30

265

24

210

30

265

Yes

Yes

300/200

450/200

300/300

450/300 (450)

GD1

30

190

30

190

30

190

30

190

Yes

Yes

300/200

375/200

300/300

375/300 (375)

GD2

24

210

30

265

24

210

30

265

Yes

Yes

300/200

450/200

300/300

450/300 (450)

L1

210

105

24

150

24

150

Yes

300/200

380/200

300/300

380/300 (380)

L2

210

105

24

150

24

150

Yes

300/200

380/200

300/300

380/300 (380)

LD1

24

150

24

150

Yes

300/200

380/200

300/300

380/300 (380)

LD2

24

150

24

150

Yes

300/200

380/200

300/300

380/300 (380)

H4

160/190 [1;4]

80/95 [1;4]

24/19

190

30/24

290

24/19

190

30/24

290

Yes

Yes

300/200

450/200

300/300

450/300 (450)

H5

210

105

19/16

210

24/19

290

19/16

210

24/19

290

Yes

Yes

300/200

440/200

300/300

440/300 (440)

Frame-mounted operator

Optosensors

Chain box operator

VL1, VL2; HLG

Optosensors

VL1, VL2; HLG

Optosensors

VL1, VL2 (HLG)

H8

16 [2]

250 [2]

16

250

Yes

Yes

300/200

450/200

300/300

450/300 (450)

HA4

160/190 [1;4]

80/95 [1;4]

24/19

190

30/24

290

24/19

190

30/24

290

Yes

Yes

300/200

450/200

300/300

450/300 (450)

HA5

210

105

19/16

210

24/19

290

19/16

210

24/19

290

Yes

Yes

300/200

440/200

300/300

440/300 (440)

HD4

24/19

190

30/24

290

24/19

190

30/24

290

Yes

Yes

300/200

450/200

300/300

450/300 (450)

HD5

19/16

210

24/19

290

19/16

210

24/19

290

Yes

Yes

300/200

440/200

300/300

440/300 (440)

HD8

16 [2]

250 [2]

16

250

Yes

Yes

300/200

450/200

300/300

450/300 (450)

HG4

160/190 [1;4]

80/95 [1;4]

24/19

190

30/24

290

24/19

190

30/24

290

Yes

Yes

300/200

450/200

300/300

450/300 (450)

HG5

210

105

19/16

210

24/19

290

19/16

210

24/19

290

Yes

Yes

300/200

440/200

300/300

440/300 (440)

HU4

160/190 [1;4]

80/95 [1;4]

24/19

190

30/24

290

24/19

190

30/24

290

Yes

Yes

300/200

450/200

300/300

450/300 (450)

HU5

210

105

19/16

210

24/19

290

19/16

210

24/19

290

Yes

Yes

300/200

440/200

300/300

440/300 (440)

RD4

24/19

190

30/24

290

24/19

190

30/24

290

Yes

Yes

300/200

450/200

300/300

450/300 (450)

RD5

19/16

210

24/19

290

19/16

210

24/19

290

Yes

Yes

300/200

440/200

300/300

440/300 (440)

RG4

160/190 [1;4]

80/95 [1;4]

24/19

190

30/24

290

24/19

190

30/24

290

Yes

Yes

300/200

450/200

300/300

450/300 (450)

RG5

210

105

19/16

210

24/19

290

19/16

210

24/19

290

Yes

Yes

300/200

440/200

300/300

440/300 (440)

V6

160/190 [1;4]

80/95 [1;4]

19

190

24

300

19

190

24

300

Yes

Yes

450/200 [3]

450/300 (450) [3]

V7

190

95

16

190

19

275

16

190

19

275

Yes

Yes

440/200 [3]

440/300 (440) [3]

V9

16 [2]

250 [2]

16

250

Yes

Yes

440/200 [3]

440/300 (440) [3]

VA6

160/190 [1;4]

80/95 [1;4]

19

190

24

300

19

190

24

300

Yes

Yes

450/200 [3]

450/300 (450) [3]

VU6

160/190 [1;4]

80/95 [1;4]

19

190

24

300

19

190

24

300

Yes

Yes

450/200 [3]

450/300 (450) [3]

VU7

190

95

16

190

19

275

16

190

19

275

Yes

Yes

440/200 [3]

440/300 (440) [3]

VU9

16 [2]

250 [2]

16

250

Yes

Yes

440/200 [3]

440/300 (440) [3]

WG6

160/190 [1;4]

80/95 [1;4]

19

190

24

300

19

190

24

300

Yes

Yes

450/200 [3]

450/300 (450) [3]

WG7

190

95

16

190

19

275

16

190

19

275

Yes

Yes

440/200 [3]

440/300 (440) [3]

[1]
[2]
[3]
[4]
[5]

74

Speed corresponding to high-lift/door height(RM)


Only possible with press-and-hold control
Twin rollers not necessary with track applications V
and VU!
Max. speed depending on the clear frame dimensions
With closing edge safety device
(optosensors, VL1 or VL2)

[6]

From 2500mm above FFL to FFL without closing


edge safety device to comply with EN13241-1

Note
Double spring shaft only possible in conjunction
with control B 460 FU!

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

Infill Overview

Infill overview

SPU F42 APU F42 APU F42 APU F42 ALR F42 ALR F42 ALR F42 ALR F42 ALR F42
S-Line
Thermo S-Line
Thermo Vitraplan Glazing

Infill type

Abbreviation

Clear synthetic pane, 3mm[1][3]

FK

FK

FK

Crystal structure synthetic pane, 3mm[1][3]

KR

KR

KR

Clear polycarbonate pane, 6 mm[3]

Multiple moulded pane (7-fold), 16mm, Ug=1.9W/(mK)[3]

PU infill, 26mm with Stucco-textured aluminium sheet cover on both sides

FU

FU

FU

FU

FU

FU

PU infill, 26mm with smooth, anodised aluminium sheet cover on both sides

XU

XU

XU

XU

XU

XU

Synthetic double pane, clear, 26mm, Ug=2.6W/(mK)

S2

S2

S2

S2

S2

S2

S2

S2

Synthetic double pane, crystal structure, 26mm, Ug=2.6W/(mK)

R2

R2

R2

R2

R2

R2

R2

R2

Synthetic double pane, grey tinted, 26mm, Ug=2.6W/(mK)

A2

A2

A2

A2

A2

A2

A2

Synthetic double pane, brown tinted, 26mm, Ug=2.6W/(mK)

B2

B2

B2

B2

B2

B2

B2

Synthetic double pane, white tinted (opal), 26mm, Ug=2.6W/(mK)

M2

M2

M2

M2

M2

M2

M2

Synthetic triple pane, clear, 26mm, Ug=1.9W/(mK)

S3

S3

S3

S3

S3

S3

S3

S3

Synthetic triple pane, crystal structure, 26mm, Ug=1.9W/(mK)

R3

R3

R3

R3

R3

R3

R3

R3

Synthetic triple pane, grey tinted, 26mm, Ug=1.9W/(mK)

A3

A3

A3

A3

A3

A3

A3

Synthetic triple pane, brown tinted, 26mm, Ug=1.9W/(mK)

B3

B3

B3

B3

B3

B3

B3

Synthetic triple pane, white tinted (opal), 26mm, Ug=1.9W/(mK)

M3

M3

M3

M3

M3

M3

M3

Polycarbonate double pane, clear, 26mm, Ug=2.6W/(mK)

C2

C2

C2

C2

C2

C2

C2

C2

Single pane of laminated safety glass, 6mm [2] [3]

VG

VG

VG

VG

E2

E2

E2

E2

E2
G2

Double pane made of single-pane safety glass, 26mm, Ug=2.6W/(mK)[2]

E2

Climatic double pane made of single-pane safety glass, 26mm,


Ug=1.1W/(mK)[2]

G2

G2

G2

G2

G2

Stainless steel expanded mesh[1][3][4]

SE

SE

SE

Perforated stainless steel sheet, perforation 8mm [1] [3] [4]

LB

LB

LB

Prepared for on-site infill[5]

BS

BS

BS

BS

BS

BS

BS

[1]
[2]

Note: max. field width 1230 mm, if required add


an additional field
Only for door width up to 6000 mm; on request,
and not in conjunction with wicket door

[3]
[4]
[5]

Not possible for aluminium frames in Thermo version


No colour coating possible
On request; infill weight and thickness must be specified

Technical Manual: Industrial Sectional Doors 42 mm/04.2014

75

Hrmann: Quality without Compromise

Hrmann KG Amshausen, Germany

Hrmann KG Antriebstechnik, Germany

Hrmann KG Brandis, Germany

Hrmann KG Brockhagen, Germany

Hrmann KG Dissen, Germany

Hrmann KG Eckelhausen, Germany

Hrmann KG Freisen, Germany

Hrmann KG Ichtershausen, Germany

Hrmann KG Werne, Germany

Hrmann Genk NV, Belgium

Hrmann Alkmaar B.V., Netherlands

Hrmann Legnica Sp. z o.o., Poland

Hrmann Beijing, China

Hrmann Tianjin, China

Hrmann LLC, Montgomery IL, USA

Hrmann Flexon, Leetsdale PA, USA

Hrmann is the only manufacturer worldwide that offers you

GARAGE DOORS

a complete range of all major building products from one source.

OPERATORS

and service companies throughout Europe, and activities in the

INDUSTRIAL DOORS
LOADING EQUIPMENT

USA and China, make Hrmann your strong partner for first-class

HINGED DOORS

building products, offering Quality without Compromise.

DOOR FRAMES

www.hoermann.com

production technologies. The close-meshed network of sales

Issue 04.2014/Print 06.2014/HF 86481 EN/PDF

We manufacture in highly-specialised factories using the latest