Professional Documents
Culture Documents
Specification No:
Rev no:
WBS No:
Product
Capacity
Pressure
TPH
Temperature
bar(g)
No of Units
2
Deg C
GENERAL NOTES
Two
Outdoor
Vendor Standard
ASME Section VIII Div.1
meters above mean sea level
Climatic Conditions
Ambient Temp. (Deg. C)
Relative Humidity (%)
Area Classification
Site Location
Phosphate Dozing
Trisodium Phosphate (Na3PO4.12H2O)
1% concentration
As per EMS 1 (D14-TB-CS-21057)
To be suitable to withstand max. & min.
ambient conditions
Application
Pressure of water at inlet
Temp. of water at inlet
Electrical Design Temp.
Two
TECHNICAL PARAMETERS
Description
Chemical to be dosed
Motors
Lubrication
Tank Parameters
Quantity Required
Minimum Storage capacity
Material of dissolving
basket, removable type
Material of Tank
MOC Thickness
Type of Tank Bottom
Pump Parameters
Quantity Required
Capacity
Type - Variable Stroke
Stroke Control
Liters
SS 304
3 mm
Dished End
Two
Liters
Reciprocating plunger type stroke
adjustable
Manually with scale having 0 to 100%
stroke adjustment indication.
Steam Drum
kg/cm2 (g)
deg. C
deg. C
1
Reflex
Level
Yes (Ext. Float type)
Switch
Breather Box
Yes
Yes
Motorised
No
Flow rate
Discharge Pressure
Normal
(kg/cm2 (g))
MOC of Wetted parts
Motors
Relief Valve
SS 316
IP 55
SS 316
Piping Details
Pipe
Size
MOC (with Desc.)
Sch/ Rating
Type
Valves
Suction
20 NB
SS-304
Sch 40
Discharge
20 NB
SS-304
Sch 40
ERW
ERW
Suction
20 NB
SS-304
800#
Ball
Flanges
Discharge
20 NB
SS-304
800#
Ball
Suction
20 NB
SS 304
150 #
SWRF
Discharge
20 NB
SS 304
150 #
SWRF
Page1 of 12
Thermax Limited
Boilers & Heaters Groups
D1 BLOCK, PLOT # 7/2, MIDC, R.D. Aga Road, Chinchwad, PUNE - 411019, INDIA
Customer:
Consultant:
Proposal No:
OC No:
Specification No:
Rev no:
WBS No:
Product
Capacity
Pressure
TPH
Temperature
bar(g)
Deg C
No of Units
2
15)
16)
17)
18)
19)
20)
21)
22)
23)
24)
NA
A
A
A
A
A
A
A
A
A
NA
5)
One no. level switch of external cage floate type for level very low alarm or interlocking purpose to be provided. The level switch should
have one SPCO contact of rating 230 VAC 5 Amp. The cable entry for the level switch should be 1/2 inch NPT(F).
Level swicth housing should be weather proof IP 65. Level switch should be flabge-mounting type and able to withstand over pressure
of 130 % of working pressure as a minimum.
6) Approved make of components:
A
Pump-plunger type : Metachem / Veekay pumps / Asia LMI.
A
PRV : Metachem/ Vekay pumps/ BHEL/ Audco? Fisher Xemox
A
Pressure gauges : H. Guru / GIC / AN Instruments / Mass of precision
A
Level gauge : Pune Techtrol
A
Drive Motorsn : Siemens/ CGL/ Kirloskar
A
Strainers : Triveni equipments / J N Marshall
A
Valves : BDK / Steel strong / Virgo.l
A
Level switch : Revati.
Page2 of 12
Thermax Limited
Boilers & Heaters Groups
D1 BLOCK, PLOT # 7/2, MIDC, R.D. Aga Road, Chinchwad, PUNE - 411019, INDIA
Customer:
Consultant:
Proposal No:
OC No:
Product
Specification No:
Rev no:
WBS No:
Capacity
Pressure
TPH
Temperature
bar(g)
Deg C
No of Units
2
PROJECT REQUIREMENTS
1)
A
Suitability for area classification.
2)
A
Special tools/ tackels for maintanence, erection & commissioning.
3)
A
Commissioning spares.
4)
A
Compliance to customer's/ consultant's attached specs.
5)
A
Compliance to attached P&I diagrams for this job.
6)
A
Tag number for complete system, pumps, motors & agitators as per P&I.
7)
A
Spark proof construction for coupling guard.
8)
A
Commissioning tools.
9)
A
Spares for 2 years operation with list (give separate price).
10)
A
Seaworthy packing, preservation & preparation for shipment.
11)
A
Compliance to EMS1 (D14-TB-CS-21057).
ADDITIONAL REQUIREMENTS
1)
2)
3)
Page3 of 12
Thermax Limited
Boilers & Heaters Groups
D1 BLOCK, PLOT # 7/2, MIDC, R.D. Aga Road, Chinchwad, PUNE - 411019, INDIA
Customer:
Consultant:
Proposal No:
OC No:
Product
Specification No:
Rev no:
WBS No:
Capacity
Pressure
TPH
Temperature
bar(g)
Deg C
No of Units
2
MADE
CHKD APPROV
DESCRIPTION
BY
BY
ED BY
All revisions are marked in the right column by a number in bold & italics. The respective revision is also shown in bold & italics.
dd/mm/yyyy
DATE
Page4 of 12
ermax Limited
& Heaters Groups
No of Units
2
REV.
REV.
Page5 of 12
ermax Limited
& Heaters Groups
No of Units
2
REV.
REV.
REV.
REV.
Page6 of 12
ermax Limited
& Heaters Groups
No of Units
2
REV.
REV.
REV.
REV.
REV.
REV.
Page7 of 12
ermax Limited
& Heaters Groups
No of Units
2
REV.
Page8 of 12
[ ] IS 48
[ ] Required, [
[ ] Required, [
[ ] Required, [
[ ] Required, [
[ ] Required, [
[ ] Required, [
required
[ ] Required, [
] Not required, [
] Not required, [
] Not required, [
] Not required, [
] Not required
] Not
] Not required
] Vendor Std.
] Vendor Std.
] Vendor Std.
] Vendor Std.