You are on page 1of 4

High Profile Power Analyser

s
vice hout
e
d
200 ork wit
rs
Netw
in a repeate

Power/eNavigator, a sophiscated Power Analyser that enables the user to navigate the full scope of an
electrical network and empowers one to manage power efficiently. The instrument offers versatile and
unmatched features and functions to monitor, profile, record events, control, log data, protect and
even check the quality of an electrical system. Power/eNavigator is built to be a one stop shop to meet
your energy management needs.

ELECON MEASUREMENTS PVT LTD


Empowers
ISO 9001 : 2008 Certified Company

Yo u

to

Manage

Power

A group of ELMEASURE INDIA PVT LTD


www.elmeasure.com

Common Features
True RMS measurement
Simultaneous sampling of Volts & Amps
Best parameters grouping /bright display
High / low recording - V, A, Hz, W, VA, PF, VAr value storage
Upgradable to higher versions
Accuracy class 1.0 IEC 61036 / CBIP 88 (0.5 option)
User programmable Password Protection
Auto-Scaling of Kilo, Mega and Giga decimal point
Neutral Current and RPM display
Clearance and creepage distance meets IEC61010 safety standard
% of unbalance V & A for all the phases
THD for Voltage and Current
Ampere hour (Ah) and PF average parameters
Programmable starting current in % of 5A secondary. Default 0.2%
Selectable VA measurement Vector/Arithmetic/Vector harmonics.
K-Factor V & A (all three phase)
Programmable parameter update rate 1sec. to 5sec. (Default 1sec.)
Programmable Auto scrolling time 1 sec. to 10 sec. (Default 5 sec.)
Features

Default

Optional Features
Digital outputs 4 potential free contacts with programmable time
delay. Hysteresis 1%
Analog Output - Two independently programmable to 0-20 mA (or)
4-20 mA output, configurable to any VLL, A, F, W, PF, VA parameters
Individual Harmonics upto 31st level for V & A
Datalogger - 1MB / 8MB optional
Dual port communication upto 2 max
Demand updation @ 1 sec
Demand Controller with 1 Relay, 2 Relay & 4 Relay
RTC can be adjusted using external communication

Additional Features for Power Navigator


Phase wise Voltage & Current Wave Forms
LCD 7 parameter display at a time, 7 digit energy value
Wave form communication through ELAudit Software
Power save mode with Enable/Disable option

Parameters

Features

Basic
Line to Neutral Voltage
Line to Line Voltage
Line Current
Neutral Current Computed
Frequency, RPM (Generator application)
V & A Phase Angle
Unbalance V & A
Power
Active Power
Apparent Power
Reactive Power
Power Factor
Energy / Integrated
Active Energy (Wh)
Apparent Energy (Vah)
Reactive Energy (VArh)
Load Hrs, No. of Interruption, Life Timer, Ah, PF Avg
Old (Energy, Load Hrs, Amp Hrs, PF Avg)
Harmonics
Voltage THD
Current THD
K Factor
Events (High/Low)
Voltage VLL, VLN High/Low
Current High/Low
Frequency High/Low
VA High/Low
W High/Low
VAr High/Low
Power Factor High/Low
Demand (Optional)
Active Power (W)
Apparent Power (VA)
Reactive Power (VAr)
Current Average (A.Avg)
Control Features (Optional)
Digital Output (Up to 4 relay)
Tripping time (1-180 sec)
Analog Output
Special Features (Optional)
Data Logging with Time stamp (1MB/8MB Optional)
Received/Delivered (Import/Export)
40A Direct measurement
Individual Harmonics
Communication (Optional)
RS-485 or RS-232 (MODBUS)

Dynamic communication - user selectable register map


Programmable - Energy display counter based or resolution base
Energy resetting @ 999999 kWh Multiplication factor

Parameters

PN7700 PN7700LM PN7710 PN7710DMC


EN8400
EN8400LM
EN8410
EN8410DMC
PN
7700 PN
7700 LM PN
7710 PN
7710 DMC

VLN Avg,VR-N,VY-N,VB-N
VLL Avg,VR-Y,VY-B,VB-R

A, AR, AY, AB, Avg


AN
Hz, RPM
VR, VY, VB, AR, AY, AB
% V, % A
W Total, WR, WY, WB
VA Total, VAR, VAY, VAB
VAr Total, VAr R, VAr Y, VAr B
PF Avg, PFR, PFY, PFB

VA Tot
VAR Tot

Wh
VAh
VArh-Ind, VArh-Cap
LH, Intr, Life count, Ontime Ah, PF Avg
Old (Wh, VAh, VArh Ind/Cap, LH, Ah, PF Avg)
THD% VR, VY, VB
THD% AR, AY, AB
K Factor: VR, VY, VB, AR, AY, AB
VLL, VLN
A
Hz
VA
W
VAr
PF
Programmable to any one of the below
Watt
Programmable sliding/
VA
fixed window, demand
period, forcast/step
VAr
demand control
A Avg
Programmable

Sliding
1 relay

RTC
Based

RTC
Based
4 relay

Under/over (VLL, A, Hz) Over (W, VA, Wh) Under (PF),


Phase rev, Single Phase, Analog I/p1, Analog I/p2

Up to 2
Refer Table 1
Wh, VAh, VArh Ind/Cap, PF.Avg, Ah, Lh
3 Phase (Hanging CT)
V & A upto 31st Harmonics

Wh, VAh

RS 232

Optional feature - no restriction on combination of options

Restricted optional feature - Combination of all restricted options may not be possible in a single product

marketing@elmeasure.com

Sliding
window
2 relay

LM : Load Manager
DMC : Demand Controller

www.elmeasure.com

Key Unique Features


Demand Management

Harmonics up to 31st level and THD


Presence of THD will urge the user to identify the polluting loads
and take necessary action to mitigate harmonics thru' an
appropriate harmonic filter and save energy and also plant &
equipments.

Monitoring - Enables understanding of the demand profile


during a billing cycle. Demand peaks with date & time can be
identified in meter as well as ElMeasure's ElNet software. The
cause of this can be studied and related with the production
events such as starting of furnace or a large motor etc., and
helps to decide on switching/staggering of loads etc.
Control - Enables user to program the threshold values of max
demand and initiate ALARM/ CUT-OFF when the Forecast
Demand/ Present Demand/ Max Demand surpasses the
threshold values. This will help the user from exceeding the
sanctioned demand.
Additional Load - By this feature the user shall be able to decide
to transfer the exact quantum of load from EB to DG or vice
versa for economic power.

Monitors Basic, Power & Energy Parameters


Provides the complete spectrum of Electrical system and help
study of load pattern.

High Low Event Recording for V, A, Hz, VA, W, VAr, PF


Protection of 3 phase system against single phasing, low & high
voltage, over load, highly lagging and leading PF, Hz etc. Power
Navigator can trap such events for future reference.

VA

Process Integration
Integration of process parameters such as temperature, Oil level,
RPM, Pressure etc. giving greater flexibility to monitor them
along with electrical parameters.

VLL

Identify & record unbalance voltage and currents and helps the
user to identify the root cause. Unbalance over-burdens the
electrical system and affects in the form of over loading of
cables, motors and switchgear.

Control Features
4 user defined potential free Digital Output based on threshold
setting for protection relay for any of Under/Over VLL, A, Hz
Over (W, VA, Wh) Under (PF), Phase reversal, Single Phase, with
programmable trip time to protect the equipments from
electrical abnormalities.

PF Management
Lower the Avg PF higher the system deficiency. So this enables
the user to maintain a healthy PF level. The Digital output
features can be used to initiate alarm when the Avg PF crosses
the user programmed threshold values (Lead/ Lag).

Power Quality Check/Management


Monitoring phase angle will help the user to identify the causes
such as deterioration in the distribution transformers, cables &
cable termination, presence of harmonics etc.

Data Logging with Time Stamp

Cross Verification of Electricity Billing


Power Navigator will help the user to cross verify with the tariff
meter and initiate suitable action if the values have a wide
disparity.

The information is needed in all types of businesses to


determine performance, quality, efficiency, cost reduction, fuel
consumption monitoring and many other critical factors.

Table 1
Energy Display programmable for counter based or Resolution based

Multiplication factor for counter based energy mode


l

Full Scale kW
3 V Pri LL x A Pri / 1000

0.4
to
4.0

Multiplication Factor:

0.01

4.01 40.1 400.1 4Mega 40 M 400 M


to
to
to
to
to
to
40 400 4,000 40 M 400 M 4000 M
0.1 1.0

10

Energy Reset : 999999 kWh Multiplication Factor

100

1000

10000

nal
Optio able
m
m
a
r
Prog Logging
Data

No of
Parameters

No of Records
1MB
8MB

121920 982080

81280 654720

48768 392839

24384 196416

14

16256 130944

29

8128

65472

1 Minute to 12 hours interval programmable. Data


interval and parameter can be selected through
RS485 communication.

Digital Outputs : (Up to 4 relay Outputs)

Applications

* 4 User defined potential free relay outputs based on


threshold setting.

Automatic connection or disconnection of


supply to Common bus

* Protection relay for any of Under/Over VLL, A, Hz Over


(W, VA, Wh) Under (PF), Phase reversal, Single Phase.

Protection of equipment from Under/ Over Voltage or


Current or Frequency

* Programmable trip time 1 to 180 sec to suit different load


conditions

Gensets

Protection of 3 phase equipment from Single phase


prevention, Over load etc.

* Rating of control relays: NO contact SPST.


250 VAC / 30 VDC @ 2 Amps resistive

TECHNICAL SPECIFICATIONS
SERIES

SPEC

POWER NAVIGATOR

Accuracy

Class 1 (Default) IEC 61036, CBIP 88,


Class 0.5, 0.5S (Option).

Sensing/
Measurement

True RMS, 1 Sec update time.


4 Quadrant Power & Energy(RD Option)

Input voltage

4 Voltage inputs (VR, VY, VB, VN)


Programmable 110 or 415V LL Nominal
(Range 80 to 550V LL) Primary
Programmable upto 999 kV.
0.2VA Max. per phase.

Burden

18 Months
Warranty

Input current

Current inputs (AR, AY, AB) 50mA - 6A


(Field configurable 1A or 5A) Primary Programmable
upto 99 kA.
Overload 10A max continuous, 50A max for 3 Sec
Burden
0.2VA Max. per phase.

Aux-Supply
(Control Power)
Burden

80 - 300V AC/DC, 40-70Hz.


48V DC - Optional
4VA Max

Display Type

eNavigator: 10 mm height bright red LED display


Power Navigator: 6 mm height Bright LCD graphical display

Display Resolution 4 digits for instantaneous, 7 digits for Integrated


parameters

Standards Applicable
Test of insulation properties
Test of Accuracy requirements
Test of electrical requirements
Radio interference suppression
Fast transient burst test
Damped oscillatory waves immunity test
Test of immunity to electromagnetic RF fields
Test of immunity to conducted disturbances,
induced by radio-frequency fields
Test of immunity to electrostatic discharges
Surge immunity test
Test of the effect of the climatic environments
Mechanical tests
Test of protection against penetration of dust
and water
Test of resistance to heat and fire

IEC 60060-1
IEC 62052-11
IEC 62052-11
CISPR 22
IEC 61000-4.4
IEC 61000-4.12
IEC 61000-4.3
IEC 61000-4.6
IEC 61000-4.2
IEC 61000-4.5
IEC 60068-2
IEC 60068-2
IEC 60529
IEC 60695-2

Mechanical Specifications
Dimension Bezel : 96 x 96 mm (Depth 50mm behind Bezel)
+0
Panel Cutout
: 92+0
-2 x 92 -2 mm

CT PT Ratio Max 2000 MVA Programmable

92 mm

RS485 serial channel connection Industry standard


Modbus RTU protocol (RS232 optional).
Baud rate 1200 bps to 19200 bps. (Preferred 9600bps)
Isolation 2000 volts AC isolation for 1 minute between
communication and other circuits.

92 mm

Communication

Weight (Approx)
Unpacked 300 gms
Shipping 400 gms
Note: Additional error of 0.05% when the current is below 500mA

Safety and Environment Specificatons


Safety
Designed to meet protection class III, pollution degree 2.
Protection against shock by double insulation.
Clearance and creepage meets UL 508 safety standard.
Finger touch proof terminals to voltage and current connections.
Operating temperature
Storage temperature
Humidity

-10C to +55C
(14F to 131F)
-25C to +70C
(-13F to 158F)
5% to 95% non condensing.

Protection index
IP 51 (IP 54 front option)
Recommended connecting wire 12 to 14 SWG with U lug of
6.75 mm width max.

ECO Friendly
Lead Free

strives for continuous product innovation.


Product specifications are therefore subject to change without notice.
Range of Products: EMS, Demand Controller, Multi-Function Meters, Load Manager,
Electronic Energy Meters, Dual Energy Meter, Digital Panel Meters, Intelligent Earth
Leakage Relay, Power Factor Controller, Motor Protection Systems, Power Distribution
Unit, Portable Analyser, Power & Energy Transducers, RS485 to RS232/Ethernet/Optic
Fiber Converter, RF Modem and GSM Modem.

ELECON MEASUREMENTS PVT LTD


Empowers

Yo u

to

Manage

Power

A group of ELMEASURE INDIA PVT LTD


HO & Unit-I

# 764, 4th Phase, 707,


Yelahanka New Town, Bangalore - 560 106. INDIA
T : +91 80 2846 1777/744 F : +91 80 41272461
CS : +91 80 3290 4489 E : contactblr@elmeasure.com

Unit-II

Goutham Garden, No. 4, Veerapandi, Coimbatore - 641019 INDIA


T : 0422 2697200. TF : 0422 2695200
E : contactcbe@elmeasure.com

Unit-III

Plot No.: 323/19, Camp Road, Selaqi, Dehradun, UTTARANCHAL


C : 097600 02492, 12492 E : contactddn@elmeasure.com

USA Contact

212 E Cullerton St., Apt 407 Chicago, IL 60616 USA

Malaysia

Siute A 806, 8th Floor, Block A, Kelana Square


17 Jalan SS7/26, Kelana Jaya, 47301 Selangor, Malaysia

Dubai

Plot No. 369-480, Warehouse No. 6 Al Quoz Ind 4, Dubai U.A.E.

www.elmeasure.com

PC/NAV/V0/0411

Environment

You might also like