Turn Winter/Summer
selector to Summer
position. Neon electric
supply illuminated
NO
Go to section A
YES
Turn DHW knob to max.
Neon DHW illuminated
NO
External control
calling for heat
NO
Go to section M
NO
Neon 5 flashing
Go to section B
YES
Go to section L
YES
3 way valve open to DHW
tank exchanger circuit
YES
Pump runs
YES
Primary flow switch
operated.
YES
Fan runs at
maximum speed
YES
Air pressure switch proved,
Blocked fan/Chimney
YES
NO
Neon 5 flashing
Go to section C
NO
Neon 3 flashing
Turn the selector to reset
NO
NO
NO
Go to section J
Neon 4 flashing
Go to section E
Neon 2 flashing
YES
NO
Change main PCB
NO
YES
NO
Go to section F
Burner does not stay alight after 10 sec.
Neon 2 flashing
Go to section I
Go to section G
YES
Burner goes out
YES
Fan stops
YES
Pump continues to
run for 3 minutes
YES
pag. 1/5
Turn Winter/Summer
selector to Winter position.
Boiler working neon
Electric Supply illuminated
NO
Go to section A
Ensure controls are set to
demand and verify the
contacts are closed
YES
NO
Turn Central Heating
thermostat to max.
Neon 10 illuminated
NO
External controls
calling for heat and
If fitted, internal
clock calling for heat
YES
Primary water is diverted
from DHW circuit to CH
system
NO
Go to section M
YES
Pump runs
YES
Primary flow switch
operated.
YES
Fan runs at
maximum speed
YES
Air pressure switch proved,
Blocked fan/Chimney
NO
NO
Neon 5 flashing
Go to section B
Neon 5 flashing
Go to section C
NO
Neon 3 flashing
Turn the selector to reset
NO
NO
YES
NO
Go to section J
Neon 4 flashing
Go to section E
Neon 2 flashing
YES
NO
Change main PCB
YES
NO
Burner lights
YES
YES
Burner output modulates
until set temperature
is reached
NO
Go to section K
Go to section F
Burner does not stay alight after 10 sec.
Neon 2 flashing
Go to section I
Go to section G
YES
Burner goes out
YES
YES
Fan stops
Pump continues to
run for 3 minutes
(room thermostat open)
YES
pag. 2/5
A
Check line voltage at:
1.
2.
3.
NO
NO
NO
Replace fuse
NO
Boiler working
neon 8 illuminated
Check wiring
Change selector
B
Check line voltage at:
1.
Pump
YES
NO
NO
Replace pump
YES
Change pump supple cable
C
1.
2.
3.
NO
Re-pressurise system
NO
Open the automatic air
YES
Replace diaphragm
Flow valve rod
obstructed
NO
1.
2.
NO
YES
Replace microswitch
Replace sensor
3.
YES
Fan jammed or
faulty winding
YES
Replace fan
pag. 3/5
E
Check and correct:
- Electrical and pressure tube
connections;
- Blockage of pressure tubes;
- Restriction in flue
- Venturi
Gas at burner
NO
NO
PCB A1 connector is
230 V AC across terminals 2,4
YES
NO
YES
Neon 2 flashing
NO
Replace main PCB
G
1.
- SIT valve:
Max burner pres. approx 4.5 V DC (7 V DC - LPG gas)
Min. burner pres. approx 0.5 V DC
Use an instrument with average function for this measure.
Current at modulating coil of gas valve is:
30230 mA DC (45310 mA DC LPG gas)
2.
YES
H
Check and correct:
1. Ignition electrode and lead
2. Electrode connection
3. Spark gap and position
YES
Voltage at main PCB A1 connector is:
230 V AC across terminals 3,4
Check wiring
NO
YES
pag. 4/5
NO
J
Overheat thermostat operated
or faulty, i.e. continuity across
thermostat terminals
YES
NO
Allow to cool.
Continuity across
thermostat terminals
more than 1,5 ohm
YES
Replace overheat
thermostat
K
Check terminal 1 on reset selector is in
connection with main PCB A4 connector
terminal 2
Electrical continuity across terminals 1,a on reset
selector when pressed
NO
YES
L
Check wiring A10 connector
Jumper on terminal 1,3
M
Check line voltage at:
1.
YES
2.
NO
YES
Change motor supple cable