FN131825&131826 Power saving for RRH60

21C&RRH2x60
Document number:
Document issue:
Document status:
Date:

UMT/BTS/DD/044675
01.03 / EN
Approved-Standard
06/08/2014
Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction

Copyright 2014 Alcatel-Lucent, All Rights Reserved

UNCONTROLLED COPY: The master of this document is stored on an electronic database and is write
protected; it may be altered only by authorized persons. While copies may be printed, it is not recommended.
Viewing of the master electronically ensures access to the current issue. Any hardcopies taken must be
regarded as uncontrolled copies.
ALCATEL-LUCENT CONFIDENTIAL: The information contained in this document is the property of AlcatelLucent. Except as expressly authorized in writing by Alcatel-Lucent, the holder shall keep all information
contained herein confidential, shall disclose the information only to its employees with a need to know, and
shall protect the information from disclosure and dissemination to third parties. Except as expressly
authorized in writing by Alcatel-Lucent, the holder is granted no rights to use the information contained herein.
If you have received this document in error, please notify the sender and destroy it immediately.
without notice. Networks assumes no responsibility for errors that might appear in t.All other brand and
product names are trademarks or regist
ered trademarks of their respective holders.

FN131825&131826 Power saving for RRH60 21C&RRH2x60

PUBLICATION HISTORY
06/AUGUST/2014
Issue 01.01 / EN, Draft
Creation. Yan Miao

18/SEPTEMBER/2014
Issue 01.02 / EN, Draft
Modification according to the comments. Yan Miao

28/November/2014
Issue 01.03/ EN, Approved-Standard
Document status changed. Yan Miao

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 2 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60

CONTENTS
INTRODUCTION .............................................................................................................. 6

1.1 OBJECT ................................................................................................. 6


1.2 FRS ...................................................................................................... 6
1.3 SCOPE OF THIS DOCUMENT ......................................................................... 6
1.4 AUDIENCE FOR THIS DOCUMENT ................................................................... 6
2

RELATED DOCUMENTS .............................................................................................. 7

2.1 APPLICABLE DOCUMENTS ............................................................................ 7


2.2 REFERENCE DOCUMENTS ............................................................................ 7
3

FUNCTION OVERVIEW .............................................................................................. 8

3.1 FEATURE OVERVIEW .................................................................................. 8


3.2 COMPLIANCE MATRIX ................................................................................. 8
4

FUNCTIONAL DESCRIPTION .......................................................................................12

4.1 PRINCIPLE ............................................................................................. 12


4.2 BTS SUPPORTED CONFIGURATIONS ............................................................... 13
4.2.1

HW REQUIREMENT .................................................................................................. 13

4.2.2

RADIO CONFIGURATION ............................................................................................ 14

4.3 ASSUMPTIONS AND RESTRICTIONS ................................................................ 14


4.4 FUNCTIONALITY DISTRIBUTION .................................................................... 14
4.4.1 FUNCTIONALITY 1 (EPIC USER STORY# 1): CALCULATION OF POWER CONSUMPTION BASED ON
CARRIER CONFIGURATION .................................................................................................. 14
4.4.1.1

<USE CASE 1:1> ................................................................................................. 14

4.4.1.2

<USE CASE 1:2> ................................................................................................. 15

4.4.1.3

FUNCTIONAL AREA IMPACTS .................................................................................. 15

4.4.1.3.1

CCM OAM ...................................................................................................... 15

4.4.1.3.2

CCM CALLP .................................................................................................... 15

4.4.1.3.3

LAYER 1/2 ..................................................................................................... 16

4.4.1.3.4

RRH ............................................................................................................. 16

4.4.1.3.5

FPGA ........................................................................................................... 17
Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction

UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 3 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60


4.4.1.3.6

LOADER ........................................................................................................ 17

4.4.1.3.7

PLATFORM SOFTWARE....................................................................................... 17

4.4.1.3.8

HARDWARE .................................................................................................... 17

4.5 FEATURE INTERWORKING .......................................................................... 17


4.6 PERFORMANCE OBJECTIVES AND IMPACTS ...................................................... 17
4.6.1

SYSTEM PERFORMANCES ........................................................................................... 17

4.6.2

MEMORY IMPACT .................................................................................................... 18

4.6.3

DIMENSIONING ....................................................................................................... 19

4.6.4

CAPACITY............................................................................................................. 19

4.6.5

DEPENDABILITY ...................................................................................................... 19

4.7 SECURITY.............................................................................................. 19
5

INTERFACES .........................................................................................................19

5.1 UMTS INTERFACES ................................................................................... 19


5.2 INTERNAL IBTS INTERFACES........................................................................ 19
5.3 EXTERNAL OAM INTERFACES ....................................................................... 19
6

OAM ...................................................................................................................19

6.1 CONFIGURATION MANAGEMENT ................................................................... 20


6.1.1

RAN OBJECTS ........................................................................................................ 20

6.1.2

RAN PARAMETERS ................................................................................................... 20

6.1.3

SEMANTIC CHECK ................................................................................................... 20

6.2 FAULT MANAGEMENT ............................................................................... 20


6.2.1

ALARMS ............................................................................................................... 20

6.2.2

STATE CHANGES..................................................................................................... 20

6.3 PERFORMANCE MANAGEMENT ..................................................................... 20


6.3.1

COUNTERS............................................................................................................ 20

6.3.2

MODULES IMPACTED BY THE NEW/MODIFIED COUNTERS:.................................................... 20

6.3.3

INTERFACES IMPACTED BY THE NEW/MODIFIED COUNTERS: ................................................ 20

6.3.4

INTERFACE IMPACTS: ............................................................................................... 21

6.3.5

TRACES ............................................................................................................... 21

6.4 I&C ..................................................................................................... 21


6.5 MISCELLANEOUS ..................................................................................... 21
Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction
UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 4 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60


7

O&M PROCEDURES .................................................................................................21

7.1 WCDMA IBTS UPGRADE ............................................................................. 21


7.2 BENIGNESS, BACKWARD COMPATIBILITY ......................................................... 21
7.3 INSTALLATION AND COMMISSIONING ............................................................. 21
8

FIELD INTRODUCTION .............................................................................................21

8.1 HARDWARE CONSTRAINTS .......................................................................... 21


8.2 MS INTERWORKING .................................................................................. 22
9

TOOLS IMPACTS .....................................................................................................22

NO IMPACT.ABBREVIATIONS AND DEFINITIONS ......................................................................22

9.1 ABBREVIATIONS ...................................................................................... 23


9.2 DEFINITIONS .......................................................................................... 24

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 5 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60

INTRODUCTION

1.1

OBJECT
This document specifies a new capability to adjust the operating mode of an RF asset to optimize
its power consumption when operating below its maximum RF power. The aim of this document is
to describe the software impact for supporting new feature.

1.2

FRS
FSD131825 Power Saving for ASB RRH2x60
FSD131826 Power saving for ASB RRH60-21C

1.3

SCOPE OF THIS DOCUMENT


The document only focuses on the support of power saving feature from software point of view..
The corresponding RRH is ASB RRH2x60 series and ASB RRH60-21C
The target release of this feature is LR15.2W (DR4 date: June, 2015).

1.4

AUDIENCE FOR THIS DOCUMENT


UTRAN R&D development and test teams.

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 6 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60

RELATED DOCUMENTS

2.1

APPLICABLE DOCUMENTS

2.2

[A1]

UMT/SYS/APR/036279

FSD131826 Power saving for RRH60-21C

[A2]

UMT/SYS/APR/043851

FSD131825 Power saving for RRH2x60 platform

[A3]

UMT/SYS/APR/0xxxxx

FSD158406 RRH2x60-21 Cost Reduction

REFERENCE DOCUMENTS
[R1]

UMT/BTS/DD/031734

FN74682 BTS serving RRH2x60 2100 Functional Specification

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 7 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60

FUNCTION OVERVIEW

3.1

FEATURE OVERVIEW
This feature is expected to adjust the drain voltage of PA(Power Amplifier) to provide minimum
power consumption for the configured RF power supported by the carrier configuration. Rather
than the previous design, this allows the reduction of power consumption for each PA.
Feature 131825 is for ASB RRH2x60 series and feature 131826 is for ASB RRH60-21C, but from RRH
software view , the implement of these two feature mostly are the same, so the solution of these
two feature will be combined together in this document.

3.2

COMPLIANCE MATRIX
Reference of the FSD131826 ed01.05.
R&D compliance
assessment

Requirement id

FN Section(s)
addressing this
requirement

Requirement description

At DR0 or DR1,
(chose the
latest
assessment
available)
Not Compliant

The ability to vary the RF assets PA drain voltage


under OAM control shall be provided.

R1

R2

SE Note This is
not so much
BBU OAM
control as RRH
internal
software
functionality.
There is no
direct
control
visibility of
internal setting
to WMS,RMT.

NA

The OAM system shall set the PA drain voltage such


that power consumption is minimized at the
maximum RF power allowable by the RF
configuration in use.

4.4.1.2

Compliant

PLM note: as examples:

when configured for 1 carrier, 20W/ carrier,


the control will minimize consumption for an

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 8 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60


RF output power of 20W;

when configured for 2 carriers, 20W/


carrier, the control will minimize
consumption for an RF output power of 40W;

when configured for 3 carriers, 20W/


carrier, the control will minimize
consumption for an RF output power of 60W.

R3

The PA drain voltage setting shall be updated


whenever the RF asset carrier/ power configuration
is changed.

4.4.1.1

Compliant

R9

The RF asset shall at all times remain compliant to


3GPP and other relevant specification when
operating with the PA drain voltage control enabled.

NA

Compliant

4.2.2

Compliant

R10

This feature shall not require any additional


downtime compared to operation before this feature
is introduced.
PLM note: this includes no additional downtime
compared to operation before this feature is
introduced for carrier adds, drops and reconfigurations.
OAM support shall be provided to manage the
configurations supported

Not Compliant

R12

R22

(This is not so
much OAM
control as RRH
internal
software
functionality.
There is no
direct control)

NA

All relevant product description and operation


documents shall be updated to include this feature.

NA

NA

NA

NA

A table shall be provided to PLM that illustrates and


describes the power savings available from this
feature. It shall include typical operating
configurations and show:

R23

power savings at maximum configured RF


power .

power savings in typical operation up to and


including the maximum configured RF
power .

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 9 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60


Reference of the FSD131825 ed01.01

Requirement id

R1

FN Section(s)
addressing this
requirement

R&D compliance
assessment

NA

NA

At DR0 or DR1,
(chose the
latest
assessment
available)

Requirement description

The RF assets covered in this feature are listed


below:

R1.1

RRH2x60-21

4.2.1

Compliant

R1.2

RRH2x60-21A

4.2.1

Compliant.

4.2.1

Compliant

R1.3

RRH2x60-850
When connected to iBTS digital units

R1.4

Not Compliant

RRH2x60-850
When connected to OneBTS digital units

R1.5

RRH2x60-1900
When connected to iBTS digital units

(The scope of
this FN is only
iBTS digital
units.)

NA

4.2.1

Compliant
Not Compliant

RRH2x60-1900

R1.6

R1.7

When connected to OneBTS digital units

RRH2x60-1900A
When connected to iBTS digital units

(The scope of
this FN is only
iBTS digital
units.)

NA

4.2.1

Compliant
Not Compliant

RRH2x60-1900A

R1.8

R2

When connected to OneBTS digital units

For the RF assets and configurations above, the RF


assets above shall meet the requirements of
FSD131826 Power Saving for RRH60-21C.

(The scope of
this FN is only
iBTS digital
units.)

NA

4.4.1.3

Compliant

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 10 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60


It is understood that this RRH2x60 family uses a
common drain voltage for both PAs. This means the
drain voltage and power consumption for both PAs is
managed in parallel and the PAs are not settable
independently. The drain voltage will be set
according to the highest power setting of the 2 PAs.
Within this feature, the savings will be made only
for assets being driven by WCMDA.

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 11 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60

FUNCTIONAL DESCRIPTION

4.1

PRINCIPLE
1) The feature is based on ASB RRH2x60 series and ASB RRH60-21C, which can support the
adjustment of PA drain voltage. According to their HW architecture, The PA has ability to set the
drain voltage via RS485 interface by RRH software.

RRH217_2440
POWER

-48V

+24V
+5.5V

AlertSig

TRX
TX1

Digital Processor
(VSWR Detecting,
LNA Controlling,
Alert reporting etc.)

+28V
+5.5V

FEU

PA
TX1_OUT

PA1_IN

PA1_OUT

TX2_OUT

PA2_IN

PA2_OUT

TX1_IN

CPRI_PRI

ANT1_OUT

RX1_OUT
CPRI_SEC

TX2

VSWR
DETECTOR

FDR1_IN
AISG

FDR

FDR1_OUT
FDR2_OUT

TX2_IN

FDR2_IN
AlertSig

SER_PORT

Digital

ANT2_OUT

RX2_OUT

CtrlSig

OCI(Ethernet)

VSWR
DETECTOR

RX1

RX1_IN

RX2

RX2_IN

RX3

RX3_IN

RX4

RX4_IN

Alert Light
RX3_OUT
ANT3_OUT

RX4_OUT
ANT4_OUT
+5.5V
AlertSig CtrlSig
VSWR Detecting

Figure 1: Brief Diagram of RRH2x60 series

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 12 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60

FEU21-W1T2R

CPRI_1

Lightning Protection

RF to digital

LNA

convertor
E
Baseband

EAC_2

Processing

RF to digital
E
(CPRI, CFR,
Power &
Control

-T

DPD, DDC,
DUC, AGC)

Lightning Protection

CPRI_2

LNA
Internal Bias

convertor

Temp
sensor

EAC_1

Aux_EAC1/2

AISG
RETA/ AISG

MCU

Digital to RF
convertor

DC(-48 V)
DC & filter

PA Fb Loop

Clock Circuits

Bias & Control

AC option
Power &
Control

TRX21-W4C

PA21-W60

Figure 2: Brief Diagram of RRH60-21C series


2) The RRH2x60 series can be configured with 2 antenna ports (1 and 2) to support STSR
x+y/VAM, and also could be configured as 2 sector configuration with 4 antennas, this is another
feature of LR15.2W, specially for ASB RRH2x60-21A. For ASB RRH60-21C, it only can be configured
either with 2 antenna ports (1 and 2) to support STSR X or VAM/STSRX+Y(with the other RRH).
3) Before the feature implement, the power consumption of PA will be reach the full level once
a carrier is configured on this PA, whatever the transmit power is. For example, even the
transmit power is configured as 1W, the power consumption of PA is still the full power. So this
would be changed when implement the feature, and the power consumption of PA is updated
according to the total transmit power of this PA.

4.2

BTS SUPPORTED CONFIGURATIONS

4.2.1 HW REQUIREMENT
Digital Unit:

D2Uv2, D2Uv3 or D2Uv5

D4Uv3

Other cabinet with D2U/D4U sub rack installed (such as 9100MBS) (TBC)

Note: from software point of view, there is no restriction of supporting all the iBTS cabinets.

<Start: FN-131825&131826-10, Requirement>


RF Assets
Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction
UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 13 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60

RRH2x60-2100

RRH2x60-850

RRH2x60-1900

RRH2x60-19A

RRH2x60-21A

RRH60-21C

<End: FN-131825&131826-10>
4.2.2 RADIO CONFIGURATION
No impact on the radio configuration, this feature will support all the existing radio
configurations, such as STSRX, STSRX+Y, Daisy Chain, VAM/MIMO and so on.
Note: when feature 176717 RRH2x60-21A support of 2 sectors and feature 165529 RRH2x601900A with 9926 digital available, there is no limitation to extend the configuration.

4.3

4.4

ASSUMPTIONS AND RESTRICTIONS

This is a pure RRH feature without any iBTS BBU modification, so the BBU behaviours are the
same as previously.

The RRH2x60 series use a common drain voltage for both PA. The drain voltage and power
consumption for both PAs is managed in parallel and the PAs are not settable independently,
RRH software will choose the highest power consumption and set to both PA.

CPRI rate 3 support is out of the current scope of the document.

FUNCTIONALITY DISTRIBUTION

4.4.1 FUNCTIONALITY 1 (EPIC USER STORY# 1): CALCULATION OF POWER


CONSUMPTION BASED ON CARRIER CONFIGURATION
The section describes the calculation of power consumption based on the carrier configuration.

<Start: FN-131825&131826-20, Requirement>


4.4.1.1 <USE CASE 1:1>
According to the ARD546 document, There are 3 types of carrier configuration request
(CARRIERCFG) which sent by BBU: carrier enable, carrier disable and carrier re-configure. The
transmit power will be included in the request, specially, the transmit power is zero for the
carrier disable case. RRH software should calculate the total transmit power on both PA. Once a
Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction
UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 14 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60


carrier configuration request is received and the total transmit power is changed, no matter
increase or decrease, RRH software will trigger the power saving scenario.

4.4.1.2 <USE CASE 1:2>


To support the feature, the new/modified scenario are involved.
The PA of RRH2x60 series and RRH60-21C supports adjustment of drain voltage to change the
power consumption, when BBU sends a carrier configuration request to RRH, RRH software will
choose an appropriate drain voltage value based on the transmit power and set it to PA.

4.4.1.3 FUNCTIONAL AREA IMPACTS

BBU

RRH TRX

PA

CARRIERCFG REQ

CARRIERCFG RSP

Calculate the total


transmit power of the PA

Choose an appropriate drain


voltage Value according to the
calculated transmit power

Set the drain voltage via RS485

Figure 3: Scenario of the drain voltage setting

4.4.1.3.1

CCM OAM
No impact.

4.4.1.3.2

CCM CallP
No impact

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 15 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60

4.4.1.3.3

Layer 1/2
No impact

4.4.1.3.4

RRH
RRH software should has a rule to select an appropriate drain voltage according to the transmit
power. Most of the RRH types has been deployed in the field for a long time before this feature,
some of these RRH has the direct correspondence between drain voltage and transmit power in
the EEPROM of PA, but some is not. So we need to find an easy way to be backward-compatible
with all the types of RRH mentioned in the FSD.
The correspondence between drain voltage and transmit power will be provided by every vendor
of RRHs, and a drain voltage/transmit power table will be introduced in to RRH software as below:

Product
-vendor
RRH2x60 21
- ASB
RRH2x60 21A 20M
- Gewei
RRH2x60 1900
- ASB
RRH2x60 1900A
- ASB
RRH2x60 850
- ASB
ASB RRH 21C
- ASB
ASB RRH 21C
- Gewei

Drain Voltage
Range

010W

1020W

2030W

3040W

4050W

5060W

>60W

24V 32V,
default = 28V

24

24

26

27

28

29

30

24

24

26

28

30

30

30

24V 32V,
default = 28V

24

26

27

28

29

30

30

24V 32V,
default = 28V

24

26

27

28

29

30

30

24V 32V,
default = 30V

24

24

26

28

28

28

28

25V 32V,
default = 28V

25

25

25

26

27

28

28

25

25

26

28

30

30

30

24V 32V,
default = 30V

25V 32V,
default = 30V

If the PA vendor detected by RRH software is not in this table, then this RRH will not benefit from
this feature, and the drain voltage will always be maximum as default.
The transmit power of each PA is split into 7 steps artificially, every power step will be mapped
to a drain voltage. When total transmit power based on the existing carriers of one PA is
calculated, RRH software will look up the table according to the corresponding PA vendor for a
Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction
UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 16 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60


proper drain voltage , then this drain voltage will be sent to PA via RS485 interface. After
received the parameter, PA will enable this drain voltage and reach the aim of power saving.
For the RRH2x60 series, 2 PA of RRH shares one PSU (Power Supply Unit) (see Figure 1), it means
the drain voltage of 2 PA should be use the same value. The strategy is choosing the higher drain
voltage of the 2 PA for setting. When a carrier configuration request received by RRH, the
calculation of total transmit power should be operated respectively on the both of PA, then the
higher of transmit power is selected to look up the drain voltage from the table and set it to the
both PA parallel.

4.4.1.3.5

FPGA
No impact

4.4.1.3.6

Loader
No impact

4.4.1.3.7

Platform Software
No impact

4.4.1.3.8

Hardware
No impact

<End: FN-131825&131826-20>
4.5

FEATURE INTERWORKING
FRS153028 RRH2x60-21A support of 2 sectors (176717) (RF Shadow)
FRS165529 RRH2X60-1900 with 4 antenna connections

4.6

PERFORMANCE OBJECTIVES AND IMPACTS

4.6.1 SYSTEM PERFORMANCES


All the modifications are inside RRH software. And the related functions are implemented during
carrier configuration phase. So no impact for system performance
iBTS Capacity impact template for x and e modules :
Processor

CCM
PQ3

CEM
PQ2

CEM
PQ3

CEM
DSP

CEM
DSP

CEM
DSP

CEM
ASIC

CEM
ASIC

TRM

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 17 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60


Core
0

Core
1

Core
2

OCC

ESIPC

Impact in
no
load
condition
without
cells up (*)
in % CPU

no

no

no

no

no

no

no

no

no

Impact in
no
load
condition
with cells
up (**) in %
CPU

no

no

no

no

no

no

no

no

no

Impact on
NBAP
transaction
processing
in % CPU

no

no

no

no

no

no

no

no

no

(*) no load condition without cells set up : CPU load observed after iBTS init just before cells set
up and without traffic.
(**) no load condition with cells set up : CPU load observed with cells up and without traffic.
Radio Equipment impact template :
RE processor (on RRH/TRDU/MCTRX)

CPU

Impact without cells up (*)

no

Impact with cells up (**)

no

(*) no load condition without cells up : CPU load observed after iBTS init just before cells set up
and without traffic.
(**) no load condition with cells set up : CPU load observed with cells up and without traffic.

4.6.2 MEMORY IMPACT


No impact. The added code would not obviously increase the memory occupancy.
CCM Memory impact template:

Type of memory

xCCM

eCCM

Impact on RAM (*)

no

no

Impact on Flash (*)

no

no

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 18 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60

CEM Memory impact template:


Type of memory

xCEM PQ2

xCEM PQ3

eCEM PQ2

eCEM PQ3

Impact on RAM (*)

no

no

no

no

Impact on Flash (*)

no

no

no

no

(*) Describe the impact after init and in traffic condition.


Memory impact on L1 component should be addressed in Tier0 document.

4.6.3 DIMENSIONING
No impact.

4.6.4 CAPACITY
No impact.

4.6.5 DEPENDABILITY
The startup time or upgrade time will not increase.
No impact for the System availability.

4.7

SECURITY
No impact.

INTERFACES

5.1

UMTS INTERFACES
No impact

5.2

INTERNAL IBTS INTERFACES


No impact

5.3

EXTERNAL OAM INTERFACES


No impact

OAM

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 19 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60

6.1

CONFIGURATION MANAGEMENT

6.1.1 RAN OBJECTS


There are no new RAN objects introduced.

6.1.2 RAN PARAMETERS


No impact.

6.1.3 SEMANTIC CHECK


None.

6.2

FAULT MANAGEMENT

6.2.1 ALARMS
No new alarms added or modified.

6.2.2 STATE CHANGES


No impact.

6.3

PERFORMANCE MANAGEMENT

6.3.1 COUNTERS
No new counters.

6.3.2 MODULES IMPACTED BY THE NEW/MODIFIED COUNTERS:


None

6.3.3 INTERFACES IMPACTED BY THE NEW/MODIFIED COUNTERS:


None
Counter#

CCM
Callp

TRM/RRH
- PM

- PM

ATM

IP

PCM

SYN

SYNCESSM

CCM

iCEM

CCM

xCEM

CCM

SLOAM-

driver

driver

driver-

driver-

driver

Callp-

Callp

Callp

PQ2

OAM-

CEM

- PM

PM

PM

iCEM

xCEM

SLOAM

PQ2

- PM

iCEM

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 20 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60


Callp

L1

(ITF2)

xCEM
PQ2

PQ3

(ITF3)

(ITF4)

(CPIF)

(ITF2)

Note: If any new interface impact needs to be mentioned, please add the same.

6.3.4 INTERFACE IMPACTS:


None

6.3.5 TRACES
No impact

6.4

I&C
No impact

6.5

MISCELLANEOUS
No impact

O&M PROCEDURES

7.1

WCDMA IBTS UPGRADE


No impact.

7.2

BENIGNESS, BACKWARD COMPATIBILITY


No impact.

7.3

INSTALLATION AND COMMISSIONING


This feature will be always activated after it is implemented, and the feature cant be shut down
by any software or hardware mothed. After the RRH software load which includes this feature is
upgraded on corresponding RRHs, the benefit will be always there.

FIELD INTRODUCTION

8.1

HARDWARE CONSTRAINTS
No impact.

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 21 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60

8.2

MS INTERWORKING
No impact.

TOOLS IMPACTS
No impact.

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 22 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60

ABBREVIATIONS AND DEFINITIONS


9.1

ABBREVIATIONS

BBU

Base Band Unit

BTS

Base Transceiver station

DxU

Digital 2U or 4U node B

WMS

WCDMA Management System

RRH

Remote Radio Head

PA

Power Amplifier

R&D

Research & Development

RF

Reverse Forward

Rx

Reception

STSR

Sectorised Tx Sectorised Rx

TRM

Transceiver Module

Tx

Transmission

Ul

Uplink

UMTS

Universal Mobile Telecommunications System

VSWR

Voltage Standing Wave Ratio

Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction


UMT/BTS/DD/044675

01.03 / EN

Approved-Standard

06/08/2014

Page 23 of 24

FN131825&131826 Power saving for RRH60 21C&RRH2x60

9.2

DEFINITIONS
Class 0: the parameter cannot be modified and a new object instance must be created or
recreated with the requested value, thanks to build process or on line creation command.
Class 2: the object instance (or the parent object instance) must be locked to modify the
parameter and the modification will be taken into account after the object instance (or the
parent object instance) has been unlocked.
Class 3: the parameter can be changed on-line without impact on the service. The new value is
taken into account either immediately or for new calls only.
Operator: the parameter is configurable from the OMC and seen by the operator
Manufacturer: the parameter is configurable from the OMC and only seen by Nortel engineering
teams

END OF DOCUMENT