You are on page 1of 28

PROGRAMMING MANUAL

CODE : 00ZXEA303VPME

LEAD-FREE SOLDER MODEL

ELECTRONIC
CASH REGISTER
MODEL

XE-A303

(For V version)

CONTENTS

LEAD-FREE SOLDER

CHAPTER 1. MASTER RESET AND PROGRAM RESET . . . . . . 1 - 1

CHAPTER 2. PROGRAM MODE . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 1

CHAPTER 3. OP X/Z, X1/Z1, X2/Z2 MODE. . . . . . . . . . . . . . . . . . 3 - 1

Parts marked with "!" are important for maintaining the safety of the set. Be sure to replace these parts with specified
ones for maintaining the safety and performance of the set.

This document has been published to be used


for after sales service only.
The contents are subject to change without notice.

LEAD-FREE SOLDER
The PWB s of this model employs lead-free solder. The LF marks indicated on the PWBs and the Service Manual mean Lead-Free solder.
The alphabet following the LF mark shows the kind of lead-free solder.

Example:
<Solder composition code of lead-free solder>

Lead-Free

5mm

Solder composition
code (Refer to the
table at the right.)

Solder composition

Solder composition code

Sn-Ag-Cu

Sn-Ag-Bi
Sn-Ag-Bi-Cu

Sn-Zn-Bi

Sn-In-Ag-Bi

Sn-Cu-Ni

Sn-Ag-Sb

Bi-Sn-Ag-P
Bi-Sn-Ag

(1) NOTE FOR THE USE OF LEAD-FREE SOLDER THREAD


When repairing a lead-free solder PWB, use lead-free solder thread. Never use conventional lead solder thread, which may cause a breakdown or an accident.
Since the melting point of lead-free solder thread is about 40C higher than that of conventional lead solder thread, the use of the exclusive-use soldering iron is recommendable.

(2) NOTE FOR SOLDERING WORK


Since the melting point of lead-free solder is about 220C, which is about 40C higher than that of conventional lead solder, and its soldering capacity is inferior to
conventional one, it is apt to keep the soldering iron in contact with the PWB for longer time. This may cause land separation or may exceed the heat-resistive temperature of components. Use enough care to separate the soldering iron from the PWB when completion of soldering is confirmed.
Since lead-free solder includes a greater quantity of tin, the iron tip may corrode easily. Turn ON/OFF the soldering iron power frequently.
If different-kind solder remains on the soldering iron tip, it is melted together with lead-free solder. To avoid this, clean the soldering iron tip after completion of soldering work.
If the soldering iron tip is discolored black during soldering work, clean
and file the tip with steel wool or a fine filer.

XE-A303 (V) LEAD-FREE SOLDER

CHAPTER 1. MASTER RESET AND PROGRAM RESET


1. MASTER RESETTING
Master resetting clears the entire memory and resumes initial values.
Master resetting can be accomplished by using the following procedure:
Procedure:
1) Unplug the AC cord from the wall outlet, or set the mode switch to OFF position.
2) Set the mode switch to the PGM position.
3) While holding down both the JOURNAL FEED key and [CL] key, plugin the AC cord to the wall outlet.
The master reset can also be accomplished in the following case.
In case power failure occurs when the machine has no battery attached to it, the master reset operation is automatically performed after the power
has been plugined the AC cord to the wall outlet.
(This is because if power failure occurs with no battery attached to the machine, all the memories are lost and the machine does not work properly
after power recovery; this requires the master reset operation.)

2. PROGRAM RESETTING (INITIALIZATION)


This resetting resumes the initial program without clearing memory.
This resetting can be operated at below sequence in PGM mode.
Procedure:
1) Unplug the AC cord from the wall outlet.
2) Wait over 1 minute for discharging.
3) Set the mode switch to the PGM position.
4) While holding down the JOURNAL FEED key and RECEIPT FEED key, plugin the AC cord to the wall outlet.
Note: In case power failure occurs when the machine has no battery attached to it, the master reset operation is automatically performed after the
power has been restored.

XE-A303 (V)

MASTER RESET AND PROGRAM RESET

11

CHAPTER 2. PROGRAM MODE


1. READING STORED PROGRAMS
The machine allows you to read every program stored in the PGM mode.

Key sequence for reading stored program


Report name

Key sequence

Programmed data1 report

TL

Programmed data2 report

23

TL

Auto key programming report

13

TL

Printer density report

33

TL

DEPT data report

43

TL

PLU data report (*)

Start No.

End No.

PLU

(*) PLU code range can be specified by entering the start and end numbers according to the following procedure.
When specifying a single time interval, PLU code, the start number has only to be entered.

SAMPLE PRINTOUTS
1. PROGRAMMED DATA1 REPORT

HEADER

01
05/02/2001 12:34PM
123456#123456 M.CLERK_____

DATE/TIME/CLERK CODE
MACHINE NO. /CC-NO. /CLERK NAME

F01 (-) xxxxxx

FUNCTION NO. /TEXT/PROGRAM (*1)


AMOUNT WITH SIGN
FUNCTION NO. /TEXT/PROGRAM (*1)
HALO WITHOUT SIGN/RATE WITH SIGN

007
-1000.00
000
-10.00%
000
-100.00%

F02 %1xxxxxxxx
L100.00%
F03 %2xxxxxxxx
L100.00%
F04 NET1xxxx
F05 DIFFERxxxxxx
:
:
9
F26 ***RAxxxxxxx
9
F27 ***POxxxxxxx
:
008
F32 CASHxxxx
008
F33 CHECKxxxxxxx
008
F34 CHECK2xxxxxx
008
F35 CREDI T1xxxxx
008
F36 CREDI T2xxxxx
002
F37 EXCH1xxxxxxx
999.999999
ABCD
F38 EXCH2xxxxxxx
:

FUNCTION NO. /TEXT

FUNCTION NO. /TEXT/HALO

FUNCTION NO. /TEXT/PROGRAM (*2)

FUNCTION NO. /TEXT/PROGRAM (*3)


CURRENCY SYMBOL/RATE
FUNCTION NO. /TEXT

:
F85
#
F86 COPY
F87 EX1 CHG
F88 AMOUNT
SHARP
PRESENTS THE
XE-A303
SHARP
IS
THE BEST
00000000
#5
00000000
#6
00000000
#7
0000
#8
0000
#10
0
#11
00
#12

00/00/0000
00:00
9999999.99
999999.99
999999.99
007
10.0000%
123.45
4.0000%
T2
0.10
-5.0000%
T3
0.20
-----T4
11
C#01 ____________
12
C#02 xxxxxxxxxxxx
:
:
00
C#25 xxxxxxxxxxxx
#13
#14
#20
#21
#22
#35
T1

(*1) (-) / % PROGRAM : ABC


A: ENTRY FOR ITEM
ENABLE
DISABLE
B: ENTRY FOR SBTL
ENABLE
DISABLE

FUNCTION NO. /TEXT

LOGO TEXT
(It is according with LOGO FORMAT.)

(JOB#5) FUNCTION SELECT


(JOB#6) PRINT FUNCTION
(JOB#7) RECEIPT PRINT FORMAT
(JOB#8) EURO FUNCTIONS
(JOB#10) POWER SAVING PROGRAMMING
(JOB#11) LOGO FORMAT
(JOB#12) EURO PROGRAMMING
(JOB#13) EURO CHANGING DATE (Printed by
Date format)
(JOB#14) EURO CHANGING HOUR
(JOB#20) SENTINEL AMOUNT
(JOB#21) CHECK CASHING LIMITATION AMOUNT
(JOB#22) CHECK CHANGE LIMITATION AMOUNT
(JOB#35) USB Timeout time
TAX1 RATE
LOWER TAX LIMIT
TAX2 RATE
LOWER TAX LIMIT
TAX3
TAX4 ( g------ h:INHIBIT)
Clerk No./Clerk name/CODE
VARIOUS PROGRAM
Refer to the programming section about the
data of each JOB.

(*2) MEDIA PROGRAM : ABC


A: Footer print on Receipt

No

Yes

B: Entry of amount tenderd

Noncompulsory (Cash, check)/Inhibit (Credit)

Compulsory

C: LIMITATION DIGITS (0=INHIBIT) = 0 to 8

C: LIMITATION DIGITS (for (-) key) = 0 to 7 (0 FIXED for [%n])


XE-A303 (V)

PROGRAM MODE

21

(*3) EXCH PROGRAM : ABC

4. PRINTER DENSITY REPORT

A: OPEN RATE ENTRY

ENABLE

DISABLE

HEADER

05/02/2001 12:34PM
01
123456#123456 M.CLERK___

B: PRESET RATE ENTRY


ENABLE

DISABLE

C: TAB

0.0

0.00

0.000

*PGM*
#50
50
10 : 0123456789AB
20 : 0123456789AB
30 : 0123456789AB
40 : 0123456789AB
50 : 0123456789AB
60 : 0123456789AB
70 : 0123456789AB
80 : 0123456789AB
90 : 0123456789AB

DATE/TIME/CLERK CODE
MACHINE NO. /CC-NO. /
CLERK NAME
MODE TITLE
Thermal printer density
Printing Sample
(Light&Shade value between
10 to 90.)

2. PROGRAMMED DATA2 REPORT


5. DEPT DATA REPORT
HEADER

01
05/02/2001 12:34PM
123456#123456 M.CLERK___
*PGM*
#61
#62
#63
#64
#65
#66
#67
#68
#69
#70
#71
GT2
#72
GT3
#76
#77
#85
#86
#87
#88

DATE/TIME/CLERK CODE
MACHINE NO. /CC-NO. /
CLERK NAME

HEADER
05/02/2001 12:34PM
01
123456#123456 M.CLERK___

MODE TITLE

00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000

(JOB#61)
(JOB#62)
(JOB#63)
(JOB#64)
(JOB#65)
(JOB#66)
(JOB#67)
(JOB#68)
(JOB#69)
(JOB#70)

OTHERS1
OTHERS2
OTHERS3
OTHERS4
OTHERS5
OTHERS6
OTHERS7
OTHERS8
OTHERS9
OTHERS10

$00000000000.00

GT2

$00000000000.00
Z1 0000
Z2 0000
___*
00
**TRAINING**
0

GT3
GENERAL Z1 RESET COUNTER
GENERAL Z2 RESET COUNTER
DOMESTIC CURRENCY SYMBOL
TRAINING CLERK
TRAINING MODE TEXT
LANGUAGE MODE
(For the fixed messages)
: OTHERS PROGRAM
Refer to the programming section
about the data of each JOB.

*PGM*
D01
T1234
DPT.01xxxxxx
G01
D02
T1234
DPT.02
G02
:
:
D99
T1234
DPT.99

073
-1234.56
073

DATE/TIME/CLERK CODE
MACHINE NO. /CC-NO. /
CLERK NAME
MODE TITLE
DEPT CODE/TAXABLE/PROGRAM (*)
TEXT
DEPT GROUP/PRICE WITH SIGN

-1234.56

071
0.00

(MAX department is decided by


PGM selection.)

(*) DEPT PROGRAM : ABC


A: REGISTRATION TYPE

NORMAL

SICS

B: LIMITATION DIGITS = 0 to 8

3. AUTO KEY PROGRAMMING REPORT


C: AMOUNT ENTRY TYPE

HEADER

05/02/2001 12:34PM
01
123456#123456 M.CLERK___
*PGM*
#01

DATE/TIME/CLERK CODE
MACHINE NO. /CC-NO. /
CLERK NAME
MODE TITLE

1
0
0
0
TL

KEY TEXT

D01
D02
D03

(DEPT01)

#02

------

DELETE (NO KEY)

XE-A303 (V)

PROGRAM MODE

22

Inhibited

Open

Preset

Open and Preset

FUNCTION LIST

6. PLU PROGRAMMING REPORT

F-NO.
HEADER

FUNCTION

DEFAULT TEXT
123456789012

(. )

(-)

%1

%1

05/02/2001 12:34PM
01
123456#123456 M.CLERK_____

DATE/TIME/CLERK CODE
MACHINE NO. /CC-NO. /CLERK NAME

%2

%2

NET1

NET1

*PGM*

MODE TITLE
START CODE/END CODE (RANGE DATA)
PLU CODE/Associated DEPT code/
Type (*1)
TEXT/PRICE WITH SIGN

DIFFER

D I FFER

TAXABLE1 ST

TA X 1 ST

TAXABLE2 ST

TA X 2 ST

TAXABLE3 ST

TA X 3 ST

0001-1800
1
-1234.56

P0001 (O1)
PLU0001xxxxx
:
:

NOTE) The deleted PLU is not printed.

P0001

----

When PLU is deleted at the


programming JOB.

(*1) PROGRAM : Y
Y: PROGRAM

SUBDEPT
PLU

VAT 2

12

VAT/TAX 3

VAT 3

13

VAT/TAX 4

VAT 4

14

TOTAL TAX (on Report)

T T L TA X

NET
NET2

NET WITHOUT TAX (on Report)

17

COUPON PLU

C P PLU

18

REFUND

REFUND

19

VOID

20

VOID MODE

p MODE

TL

(for CASH)

21

MANAGER VOID

MGR p

22

SBTL VOID

SBTL p

23

HASH VOID

HASH p

24

HASH REFUND

HASH RF

25

NO SALE

NO S A L E

26

RA

***RA

27

PO

***PO

28

CHECK CASHING

CA/CHK

No

Yes

29

CUSTOMER (TRANS. COUNT)

GUEST

30

PAID TOTAL

PA I D TL

31

AVERAGE

AVE.

32

CASH

CASH

33

CHECK1

CHECK1

34

CHECK2

CHECK2

35

CREDIT1

CRED I T1

36

CREDIT2

CRED I T2

37

EXCHANGE (PRESET RATE)

EXCH1

38

EXCHANGE (OPEN RATE)

EXCH2

NO CHANGE

39

EXCHANGE IS

EXCH1

(CHARACTERS)

40

EXCHANGE1 CHECK

EX 1 CHK

41

EXCHANGE1 CREDIT TOTAL

EX 1 CR

42

CASH IN DRAWER

****C I D

43

CASH/CHECK IS

CA / CH I S

44

CASH/CHECK IN DRAWER

CA / CH I D

45

CHECK CHANGE

CHK / CG

46

DOMESTIC CURRENCY1

DOM. CUR1

47

DOMESTIC CURRENCY2

DOM. CUR2

48

DOMESTIC CURRENCY FOR EX1 CHECK DOM. CUR1

49

DOMESTIC CURRENCY FOR EX1 CREDIT DOM. CUR1

50

CHECK IN DRAWER

* CH

51

GROUP1

GROUP1

52

GROUP2

GROUP2

B: Entry of amount tenderd


Non-compulsory

Compulsory

C: LIMITATION DIGITS (0 = INHIBIT)


= 0 to 8
MRS = 008

2) PROGRAMMING OF FUNCTION TEXT


3

VAT/TAX 2

NET2

ST

VAT 1

11

15

( [#/ST] key is used for programming of CASH.)

A: Footer print on Recipt

TA X 4 ST

VAT/TAX 1

16

1) PROGRAMMING FOR MEDIA KEYS & FUNCTION KEYS

#/ST

TAXABLE4 ST

2. USER PROGRAMMING

ABC

9
10

XX

ST

TL

XX: FUNCTION CODE (Refer to the FUNCTION LIST)


(CHARACTERS): CHARACTER (Max. 12 Characters)
Characters can be entered by using the character layout on keyboard or
using numeric keys on keyboard.
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER
BY NUMERIC KEYS IS AS FOLLOWS:
YYY3 [00] KEY
YYY: CHARACTER CODE (3 DIGITS)
( or [000] KEY ACCORDING TO PGM PRESET)
MRS = Refer to the following table
XE-A303 (V)

PROGRAM MODE

23

ID

IS

F-NO.

DEFAULT TEXT
123456789012

FUNCTION

(Sample)

53

GROUP3

GROUP3

54

GROUP4

GROUP4

123456789012345678901234567890
SHARP

55

GROUP5

GROUP5

PRESENTS THE

56

GROUP6

GROUP6

57

GROUP7

GROUP7

58

GROUP8

GROUP8

59

GROUP9

GROUP9

60

(+) DEPT TOTAL

*DEPT

61

(-) DEPT TOTAL

DEPT (-)

62

HASH (+) DEPT TOTAL

*HASH

63

HASH (-) DEPT TOTAL

HASH (-)

64

NET 1 (TAXABLE1-VAT1)

NET 1

65

NET 2 (TAXABLE2-VAT2)

NET 2

66

NET 3 (TAXABLE3-VAT3)

NET 3

XE-A303
SHARP
IS
THE BEST

MRS =

TL

3) PROGRAMMING OF CLERK NAME

TL

NO CHANGE
ST

(CHARACTERS)

XX

ST

TL

XX: CLERK NO. (1-25)


(CHARACTERS): CHARACTER (Max. 12 Characters)

67

NET 4 (TAXABLE4-VAT4)

NET 4

68

SUBTOTAL

SUBTOTAL

69

MDS SBTL

MDSE ST

70

TOTAL

* * * TOTAL

71

CHANGE

CHANGE

72

ITEMS

I T EM S

73

DUE (on DISPLAY)

DUE

74

CCD

75

CCD DIFFER

CCD DI F.

76

CCD DIFFER TOTAL

D I F.

77

DEPT. REPO. TITLE

78

GROUP. REPO. TITLE

79

PLU REPO. TITLE

80

TRANS. REPO. TITLE

81

CID REPO. TITLE

82

CLERK REPO. TITLE

83

HOURLY REPO. TITLE

84

DAILY NET REPO. TITLE

DEPT
GROUP
PLU
TRANS.
TL - I D
CLERK
HOURL
Y
DA I L Y

85

NON ADD CODE TEXT (8chara)

86

COPY RECEIPT TITLE

87

EXCHANGE1 CHANGE (on DISPLAY)

EX1 CHG

88

AMOUNT (for AMOUNT ENTRY DISPLAY)

AMOUNT

Characters can be entered by using the character layout on keyboard or


using numeric keys on keyboard.
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER
BY NUMERIC KEYS IS AS FOLLOWS:
YYY3 [00] KEY
YYY: CHARACTER CODE (3 DIGITS)
(or [000] KEY ACCORDING TO PGM PRESET)

CCD

MRS = CLERKxx (xx: CLERK code 1 to 4)

4) FOREIGN CURRENCY SYMBOL PROGRAMMING

TL

NO CHANGE
ST

ST

(CHARACTERS)

TL

(CHARACTERS): CHARACTER (Max. 4 Characters)


Characters can be entered by using the character layout on keyboard or
using numeric keys on keyboard.
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER
BY NUMERIC KEYS IS AS FOLLOWS:
YYY3 [00] KEY
YYY: CHARACTER CODE (3 DIGITS)

(or [000] KEY ACCORDING TO PGM PRESET)

COPY

MRS = ____

(_: space code)

Note: This symbol is printed as the amount of EXCHANGE for PRESET


RATE only.
The amount symbol of EXCHANGE for OPEN RATE is not printed.

2) PROGRAMMING OF LOGO TEXT


5) CLERK CODE DEFINITION

NO CHANGE
ST

X
LINE NO.

(CHARACTERS)

ST

TL
ST

16

XX

XX: CLERK NO. (1 to 25)

X: LINE NO. (1-6)

YY: CLERK CODE (00 to 99)

(CHARACTERS): CHARACTER (Max. 30 Characters)


Characters can be entered by using the character layout on keyboard or
using numeric keys on keyboard.
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER
BY NUMERIC KEYS IS AS FOLLOWS:
YYY3 [00] KEY
YYY: CHARACTER CODE (3 DIGITS)
( or [000] KEY ACCORDING TO PGM PRESET)

XE-A303 (V)

PROGRAM MODE

24

YY

ST

TL

6) TAX RATE PROGRAMMING

9) DATE, TIME PROGRAMMING


XXXXXXXX
DATE

(Inhibition programming)
VOID (

#/TM

HHMM
TIME
9

ST

YXXX.XXXX

TAX No.

TAX RATE
& SIGN

DATE) XXXXXXXX: YYYYMMDD (Year-month-day) or


DDMMYYYY (Day-month-Year) or
MMDDYYYY (Month-day-Year)

(YYYY: 2000-2099)
xxxxx
LOWER TAX LIMIT
FOR ADD TAX

TL

ST

(MM: 01-12)
(DD: 01-31)
The date entry format complies with the applicable PGM-mode
programming.

A: TAX 1 PROGRAMMING = 1
TAX 2 PROGRAMMING = 2

TIME)

TAX 3 PROGRAMMING = 3

HH: Hour (00 to 23)


MM: Minute (00 to 59)

TAX 4 PROGRAMMING = 4
% TAX RATE & SIGN

MRS = DATE: 01012000 (DD/MM/YYYY)

Y: SIGN

XXX.XXXX: RATE

TIME: 0000

10) VARIOUS PROGRAMMING


(EACH FUNCTIONS PROGRAMMING)

= 0.0000 to 100.0000 %

LOWER TAX LIMITATION 0.00 to 999.99


(This is invalid in VAT system.)

There are programmed by depressing [ST] key after a data that want to set.
And it is operated continuously until depressing the [TL] key

MRS = DELETE

(Programming sequence)
0

ST

7) AUTO KEY PROGRAMMING

(Free key)

(NK)

AUTOn

TL

TL

[JOB#1] MACHINE No. (6digits)


Delete

-- XXXXXX --

MRS = 000000

It must be pushed same [AUTO] key as the programming [AUTO] key at


the end of any key entry.

[JOB#2] CONSECUTIVE No. (6digits)

[JOB#5] FUNCTION SELECT

< Auto key function >

-- ABCDEFGH --

MRS = 00000001

This machine has [AUTO] key which can be programmed the keysequence data.
When [AUTO] key is depressed, the machine works as same as the
programmed key-sequence is entered.

A: PO in REG mode

Executing mode : REG, MGR, OPXZ, X1/Z1, X2/Z2


: PGM

8) EURO STATUS FUNCTION


The ECR has a EURO STATUS in the preset memory.
It is changed by EURO CHANGING JOB and confirmed by EURO STATUS READING JOB at Z2 mode. Refer XZ report section.

DISABLE

PROGRAM MODE

ENABLE

DISABLE

C: SUBTOTAL VOID in REG mode

25

ENABLE

B: RA in REG mode

XE-A303 (V)

-- XXXXXX --

MRS = 000000

Note: [ESC] key cannot be set at [AUTO] key programming.


It acts as a key of ERROR ESCAPE function in this programming.

Setting mode

ST

AB : JOB No.
NK : PROGRAMMING DATA. (Numeric Keys)

max 25
AUTOn

AB

ENABLE

DISABLE

D: INDIRECT VOID in REG mode

[JOB#7] RECEIPT PRINT FORMAT

ENABLE

DISABLE

-- ABCDEFGH --

MRS = 00000000
A, B: Not used (Fixed at 00)

C: SUBTOTAL PRINT AT [ST] - KEY


E: DIRECT VOID in REG mode

ENABLE

DISABLE

NOT PRINT

PRINT

D: Not used (Fixed at 0)


F: REFUND in REG mode

ENABLE

DISABLE

G: NO SALE in REG mode

ENABLE

DISABLE

H: FRACTIONAL QUANTITY
YES (3digits decimal place)
NO

[JOB#6] PRINT FORMAT

E: VAT/TAX AMOUNT PRINTING

NOT PRINT

F: TAXABLE AMOUNT PRINTING

NOT PRINT

PRINT

NOT PRINT

H: PURCHASE NO. PRINTING

-- ABCDEFGH --

MRS = 00000111

PRINT

G: NET AMOUNT PRINTING

PRINT

PRINT

NOT PRINT

A: Not used (Fixed at 0)

[JOB#8] EURO FUNCTIONS


B: PRINT

FULL PRINT

JOURNAL SELECT

C: TIME PRINTING (for all receipt)

NOT PRINT

NOT PRINT

No

Yes

C: CHECK,CREDIT operation for EX

Yes

D: EXCHANGE Calculation method

Division

[JOB#10] POWER SAVING

MRS = 0030
Y: POWER SAVING function when a time is displayed

SEPARATOR LINE

SKIP

H: ZERO SKIP IN GENERAL, CLERK, HOURLY,


DAILY REPOT
NOT SKIP
SKIP

NOT SKIP

-- YXXX -Y

Yes (Enable)

No (Disable)

XXX: POWER SAVING TIME to POWER OFF


= 001--254 (minutes)
or 999 (Inhibit)

[JOB#11] LOGO PRINTING

-- A --

MRS = 5
A: LOGO MESSAGE CONTROL

0
1

NOT PRINT

1 LINE FEED

Multiplication
0

G: ZERO SKIP IN PLU REPORT

No

PRINT

F: SEPARATER LINE IN XZ REPORT

B: Not used (Fixed at 0)

PRINT

E: CONSECUTIVE NO. PRINTING

MRS = 0000
A: Printing of EX amount for Total and Change

PRINT

D: DATE PRINTING (for all receipt)

-- ABCD --

XE-A303 (V)

PROGRAM MODE

26

3-LINE HEADER INSTEAD OF GRAPHIC LOGO

GRAPHIC LOGO ONLY

GRAPHIC LOGO AND 3-LINE FOOTER

6-LINE HEADER

GRAPHIC LOGO AND 3-LINE HEADER

3-LINE HEADER AND 3-LINE FOOTER

[JOB#12] EURO Programming

-- AB --

MRS = 00
A: Automatic converting the unit price at EURO

[JOB#61] OTHERS1 PROGRAMMING

NO

B: The EURO CHANGING JOB at the date of


exchanging the currency between LOCAL and
EURO.

MRS = 00100112
A, B: Not used (Fixed at 00)

YES

C: Programming of MINUS dept/PLU

Compulsory

Non-compulsory

-- ABCDEFGH --

Enable

D: Fractional treatment

[JOB#13] The date of exchanging the currency between


LOCAL and EURO -- XXXXXXXX --

Raising to unit

Disregarding

DATE) YYYYMMDD (Year-month-day) or


DDMMYYYY (Day-month-Year) or
MMDDYYYY (Month-day-Year)
[YYYY:2000-2099]
[MM:01-12]
[DD:01-31]

000 key

The date entry format complies with the applicable PGM-mode programming.
In case of date setting is 0, EURO date function is not work.

24hour

M-D-Y

D-M-Y

Y-M-D

H: TAB

[JOB#14] The Time (hour only) of exchanging the currency


between LOCAL and EURO -- XX --

12hour

G: Date format

00 key

F: Time format

Round off (4-DOWN, 5-UP)

E: 00 key or 000 key selection for 00 key position

MRS = 00000000 (DD/MM/YYYY)


XXXXXXXX: (DATE)/00000000 (Function Inhibit)

Disable

MRS = 00

[JOB#62] OTHERS2 PROGRAMMING -- ABCDEFGH -XX: Hour (00-23)

[JOB#20] SENTINEL (CID HALO)

MRS = 01000000
A: Not used (Fixed at 0)

-- XXXXXXXXX --

B: ERROR BEEP for missoperation

MRS = 999999999
XXXXXXXXX: SENTINEL AMOUNT (9digits)

LOCK ERROR

MISSOPERATION

C: Key catch sound

[JOB#21] CHECK CASHING (HALO) -- XXXXXXXX -MRS = 99999999


XXXXXXXX: LIMITATION AMOUNT (8digits)

MRS = 99999999

No

[JOB#35] USB Communication TIME OUT -- XXX --

No

Disable

Yes

XXX: Time out time (1 - 255 sec)

No

G: Printing of VOID MODE in X1/Z1 report

MRS = 50

MRS = 007

[JOB#50] THERMAL PRINTER DENSITY CONTROL -- XX --

Enable

F: Printing of VOID MODE in X2/Z2 report

Yes

E: VOID mode

XXXXXXXX: LIMITATION AMOUNT (8digits)

Yes

D: Buffered Keyboard

[JOB#22] CHECK CHANGE (HALO) -- XXXXXXXX --

Yes

No

XX: density (00-99)


H: Addition to the hourly total in VOID MODE

00: 70 % for standard


50: 100 % (Standard density)
99: 130 % for standard
XE-A303 (V)

PROGRAM MODE

27

No

Yes

[JOB#63] OTHERS3 PROGRAMMING -- ABCDEFGH --

[JOB#65] OTHERS5 PROGRAMMING -- ABCDEFGH --

MRS = 01000001

MRS = 00000000

A: Receipting at the time of NO SALE

Yes

No

B: NO SALE after non-add code entry

Disable

Enable

C: NON-ADD code entry

Disable

Yes

Disable

Noncompulsory

Compulsory

No

Yes

No

Yes

Compulsory

Disable

Enable

OVERLAPPED CLERK

ENABLE

DISABLE

ENABLE

H: CCD COMPULSORY

NON-COMPULSORY

FOR INDIVIDUAL CLERK

FOR ALL CLERK

[JOB#64] OTHERS4 PROGRAMMING -- ABCDEFGH --

DISABLE

G: LOOKING OF REG MODE ENTRY AFTER INDIVIDUAL CLERK RESETTING

NORMAL

F: IN CASE OF INDIVIDUAL AND ALL CLERK CCD,


X REPORT BEFORE CCD ENTRY

Noncompulsory

H: Direct non-tender finalization after tendering

Yes

D: Printing of Training GT on X report

No

E: CLERK SYSTEM
0

G: Subtotal entry before direct non-tender finalization

Enable

F: Subtotal entry before tendering

Yes

C: Printing of GT3 on X report

No

E: Entry that causes the merchandise SUBTOTAL


to be smaller then zero.

No

B: Printing of GT2 on X report

Enable

D: Copy Receipt

A: Printing of GT1 on X report

MRS = 00000000
A: Printing of GT1 on Z report

Yes

No

B: Printing of GT2 on Z report

No

Yes
No
D: Printing of Training GT on Z report

F: Printing of DATA on PLU resetting report

No

Yes

C: CONVERSION SBTL PRINTING OF NATIVE


SBTL

Yes

No

D: VAT/TAX-assignment print

1
F
0

No

Yes

Disable

NOT

G: Logo Text Print on Journal

XE-A303 (V)

PROGRAM MODE

28

No

Yes

H: FOOTER PRINT CONTROL

Enable

PRINT

E, F: Not used (Fixed at 00)

No

H: OP X/Z report

DETAILS

Yes

G: Reset GT 1, 2, 3 at the general Z1 report

TOTAL ONLY

B: AMOUNT PRINTING WHEN PLU UNIT PRICE IS 0

No

No

Yes

A: AFTER-TRANSACTION RECEIPT

Yes

E: Printing of Z counter on Z report

MRS = 10010000

Yes

C: Printing of GT3 on Z report

[JOB#66] OTHERS6 PROGRAMMING -- ABCDEFGH -

ALL RECEIPTS

ON SELECTED FUNCTION KEY AT THE


TIME OF FINALIZATION

[JOB#67] OTHERS7 PROGRAMMING -- ABCDEFGH --

[JOB#69] OTHERS9 PROGRAMMING -- ABCDEFGH --

MRS = 00000000

MRS = 00001000
A, B, C: Not used (Fixed at 000)

MRS = 11821012 (only for SCA)


A: Printing of rounding amount (for SCA)

No

D: Rounding of foreign currency for Exchange

Yes

B: TOTAL AMOUNT ROUNDING when a transaction is finalized directly by CHECK or CREDIT


key (for SCA)
(This selection is not effective at Manual TAX
system)

Raising to unit

Round off (4-DOWN, 5-UP)

E: TAX SYSTEM

AUTO TAX1-4

AUTO VAT1-4

YES (Rounding)

MANUAL VAT1-4

NO (Not rounding)

MANUAL VAT1

MANUAL TAX1-4

AUTO VAT1 & AUTO TAX 2-4

C: ROUNDING UP OF THE UNIT DIGIT OF AMOUNT = 0 to 9


D: ROUNDING DOWN OF THE UNIT DIGIT OF AMOUNT = 0 to 9
Example) CD= 00:COMMON DESTINATION
82: SWITZERLAND
82: NETHERLAND
54: NORWAY

F: TAX PRINTING WHEN TAXABLE SUBTOTAL


IS ZERO

Item C and D must be handled as a pair. Its action is as follow.

Other cases :
Unit Digit of Amount < or = Value of (D) 3 Rounding Down
Value of (D) < Unit Digit of Amount < Value of (C) 3 Rounding to 5
Value of (C) < or = Unit Digit of Amount 3 Rounding Up
E: APPLICATION OF ROUNDING

ITEM & PAYMENT

PAYMENT

F: LIMIT ON THE LEAST SIGNIFICANT DIGIT IN


ENTERING THE AMOUNT OF ITEM

0 ONLY

0 AND 5 ONLY

G: DIFFERENCE MEMORY
(DIFFERENCE BETWEEN BEFORE-ROUNDING AND AFTER-ROUNDING)

Yes

No

NORMAL

SWEDEN

DENMARK

[JOB#70] OTHERS10 PROGRAMMING -- ABCDEFGH -MRS = 00000000


A: SPLIT PRICING COUNRING

ARBITARY

Yes

H: ROUNDING SYSTEM

No

G: TAX PRINTING WHEN TAX IS ZERO

Case of C=0 :
Unit Digit of Amount < or = Value of (D) 3 Rounding Down
Value of (D) < or = Unit Digit of Amount 3 Rounding to 5

Quanitity

Package

B, C, D, E, F, G, Not used (Fixed at 0000000)


H:

[JOB#71] GT2 PROGRAMMING -- XXXXXXXXXXXXX --

No

MRS = 0000000000000

Yes

XXXXXXXXXXXXX: GT (13digits)

[JOB#72] GT3 PROGRAMMING --- XXXXXXXXXXXXX --

H: LIMIT ON THE LEAST SIGNIFICANT DIGIT IN


ENTERING THE AMOUNT OF PAYMENT
ARBITARY

0 ONLY

0 AND 5 ONLY

MRS = 0000000000000
XXXXXXXXXXXXX: GT (13digits)

[JOB#76] GENERAL Z1 RESET REPORT COUNTER


-- XXXX --

[JOB#68] OTHERS8 PROGRAMMING -- ABCDEFGH --

MRS = 0000

MRS = 00000000
MRS = 10000000 (only for SCA)
A: Printing of split pricing entry

XXXX: RESET COUNTER (4digits)


A

Normal

[JOB#77] GENERAL Z2 RESET REPORT COUNTER


-- XXXX --

SCA format

MRS = 0000
XXXX: RESET COUNTER (4digits)

B, C, D, E, F, G, H: Not used (Fixed at 0000000)

[JOB#86] TRAINING CLERK PROGRAMMING


MRS = 0
X: CLERK No. = 0 (INHIBIT), 1 to 25
XE-A303 (V)

PROGRAM MODE

29

-- XX --

12) DOMESTIC CURRENCY SYMBOL PROGRAMMING

14) TEXT CHANGING (TO DEFAULT TEXT)

NO CHANGE
ST

85

(CHARACTERS)

0
ST

TL

ST

Characters can be entered by using the character layout on keyboard or


using numeric keys on keyboard.
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER
BY NUMERIC KEYS IS AS FOLLOWS:

TL

MRS = 0

YYY 3 [00] KEY


YYY: CHARACTER CODE (3 DIGITS)
(or [000] KEY ACCORDING TO PGM PRESET)

When this job is executed, below texts are set as default data.
(a) Function text
(b) Each message text (LOGO, etc..)
(c) CLERK name

( _: space code)

This symbol is printed with (+) amount of domestic currency.


The programmed characters is printed at left side of amount.
Ex) Case of " DM ":
| DEPT.01

X: 0 = English text
1 = German text
2 = French text
3 = Spanish text

(CHARACTERS): CHARACTER (Max. 4 Characters)

MRS = ___*

88

DM1.00 |
2
Programmed symbol

HEADER

If some space characters are programmed at the left side of symbol


(like " *"), they are not counted as the number of character of the currency symbol. (In case of " DM", the number of character is 2.)
Ex) Case of " DM": (The currency symbol means "DM")
|AAAADEPARTMENT01 DM10000.00 |
2
Programmed symbol

05/02/2001 12:34PM
01
123456#123456
M.CLERK_____

DATE/TIME/CLERK CODE
MACHINE NO. /CC-NO. /
CLERK NAME

*PGM*

MODE TITLE

#88

LANGUAGE MODE

13) TRAINING MODE TEXT PROGRAMMING


NO CHANGE
ST

87

(CHARACTERS)

ST

TL

15) RESETTING OF ALL COUNTER AND TOTALIZER


ST

(CHARACTERS): CHARACTER (Max. 12 characters)


Characters can be entered by using the character layout on keyboard or
using numeric keys on keyboard.
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER
BY NUMERIC KEYS IS AS FOLLOWS:

89

TL

All counter, totalizer, all GTs, and all Z counter are reset.

YYY 3 [00] KEY


YYY: CHARACTER CODE (3 DIGITS)
(or [000] KEY ACCORDING TO PGM PRESET)
HEADER

MRS = **TRAINING**

XE-A303 (V)

05/02/2001 12:34PM
01
123456#123456
M.CLERK_____

DATE/TIME/CLERK CODE
MACHINE NO. /CC-NO. /
CLERK NAME

*PGM*

MODE TITLE

#89

JOB#

PROGRAM MODE

2 10

4. CHARACTER ASSIGNMENT METHOD


PROGRAMMING KEY LAYOUT

36

31

26

21

17

12

37

32

27

22

18

13

38

33

28

23

19

14

39

34

29

24

20

15

10

40

35

30

25

11

16

Note: The small characters on the bottom or lower right in each key indicates functions or characters which can be used for character entries for text
programming.

THE METHOD OF CHARACTER ENTRY AT TEXT PROGRAMMING


The character can be entered by using character key or character code.
When the character can be entered in the text programming, the key layout is changed from Function and DEPT key layout to CHARACTER KEY
LAYOUT.
In CHARACTER KEY LAYOUT, any key except the Numeric keys and [CL], [SBTL], [TL] are assigned either the character or the control key for character entry.
Any character can be entered by following method.
By character key:
SHIFT

(CHARACTER KEY)

: Characters on Character key layout.

NUMBER

(NUMERIC KEY)

: Numeric character ("0", "1", . . . , "9")

By Numeric key (Character Code) :


xxx

[00]

xxx: Character Code

(The list of Control Key)


Key
SHIFT

Action
Entry to shift the following character key. (ex. [SHIFT]) 3 [A]: Enter the character a.)

NUMBER Entry the following numeric key as the number character. (ex. [NUMBER] 3 [1]: Enter the character 1.)
(DC)

Double size character: Change the following character to the double size character.

BS

Back Space: Delete the last character.

The status of [SHIFT], [NUMBER] and [DC] are keeping until pushing same control key in each text entry. (STAY DOWN type)
And the corresponding indication is lighted up on the display while their status is on.
(Example)
[SHIFT] 3 [A] [B] [C] 3 [SHIFT] 3 [A] [B] [C]

: Text abcABC.

[NUMBER] 3 [1] [2] [3] 3 [NUMBER] 3 [1] [2] [3] : Text 123 and numeric number 123.
[DC] 3 [A] [B] [C] 3 [(DC)] 3 [A] [B] [C]

: Text ABCABC.

XE-A303 (V)

PROGRAM MODE

2 11

<Character Code Table for text programming> Printer


CODE

CHARACTER

CODE

CHARACTER

CODE

CHARACTER

CODE

CHARACTER

CODE

001

049

098

147

196

002

050

099

148

197

003

051

100

149

198

004

052

101

150

199

005

053

102

151

200

054

103

152

201

007

055

104

153

202

008

056

105

154

203

009

057

106

155

Pt

204

010

058

107

156

205

059

108

157

206

060

<

109

158

207

061

110

159

208

062

>

111

160

209

063

112

161

210

064

113

162

211

017

065

114

163

212

018

066

115

164

019

..

067

116

165

020

068

117

166

118

167

069
070

119

168

006

011

012
013

014
015
016

021

022

023

024

025

026

027

028
029

030
031

032

(Space)

CHARACTER

213
.

071

120

169

072

121

170

073

122

171

074

123

172

075

124

173

214

215

216

217

218

219

220

221

222

223

224

076

125

174

077

126

175

078

127

079

128

!!

177

080

129

178

227

081

130

179

228

082

131

180

229

083

132

181

230

084

133

182

231

085

134

F
T

183

232

086

135

184

233

087

136

185

234

176

225

226

033

034

"

035

036

037

038

&

039

'

088

137

186

235

040

089

138

187

236

041

090

139

188

237

042

091

140

189

238

043

092

141

190

044

093

142

191

045

094

143

192

046

095

144

193

047

096

145

194

048

097

146

195

253

(DC)

/2

(DC): Double Code


<Character Code Table for text programming> Display
: ECR Control Character (Not used for text)
XE-A303 (V)

PROGRAM MODE

2 12

<Character Code Table for text programming> for DISPLAY


CODE

CHARACTER

CODE

CHARACTER

CODE

CHARACTER

CODE

CHARACTER

CODE

CHARACTER

001

049

098

147

196

(Space)

002

050

099

148

197

(Space)

003

051

100

149

198

(Space)

004

052

101

150

199

(Space)

005

053

102

151

200

(Space)

(Space)

054

103

152

201

(Space)

055

104

153

202

056

105

154

203

(Space)

009

057

106

155

Pt

204

(Space)

010

058

107

156

205

(Space)

059

108

157

206

060

<

109

158

207

061

110

159

(Space)

208

062

>

111

160

209

(Space)

063

112

161

210

064

113

162

211

065

114

163

212

066

115

164

213

067

116

165

(Space)

214

006
007
008

011

(Space)

012
013

014
015
016
017
018

019

(Space)

020

068

117

166

(Space)

215

069

118

167

(Space)

216

070

119

168

(Space)

217

071

120

169

(Space)

218

072

121

170

(Space)

219

073

122

171

(Space)

220

(Space)

074

123

172

(Space)

221

(Space)

075

124

173

(Space)

222

(Space)

076

125

174

(Space)

223

(Space)

077

126

175

(Space)

224

078

127

176

(Space)

225

(Space)

079

128

177

226

080

129

178

(Space)

227

081

130

179

(Space)

228

(Space)

082

131

180

(Space)

229

083

132

181

(Space)

230

084

133

(Space)

182

(Space)

231

(Space)

085

134

(Space)

183

(Space)

232

086

135

184

(Space)

233

087

136

185

(Space)

234

021
022

023

024

025

026

027

028
029

030
031

032

(Space)

033

(Space)

034

"

035

036

037

038

&

039

'

088

137

(Space)

186

(Space)

235

040

089

138

(Space)

187

(Space)

236

041

090

139

188

(Space)

237

042

091

140

189

(Space)

238

043

092

141

190

044

093

142

191

045

094

143

(Space)

192

046

095

144

193

047

096

145

194

048

097

146

195

253

(DC)

(DC):

Double Code
: ECR Control Character (Not used for text)
XE-A303 (V)

PROGRAM MODE

2 13

(Space)

5. EASY PROGRAMMING
Easy programming roughly consists of the following two types of programming.
1. Direct key or code entry type.

1. DIRECT KEY OR CODE ENTRY TYPE


<Programming method>
At PGM mode, it becomes set up mode, as it pushes a key of a direct
key or code entry that it wants to set up.

2. Guidance message type on usual programming.


Reports that show the contents of individual programming can be
printed.

[PURPOSE]
It aims to be able to program easily by using the guidance messages by
the easy programming.

[OPERATION]
Perform the programming to enter the parameter according to the guidance message.
The guidance message is displayed on the LCD-display every time.
It shows the information related the entry data at each step.
Each programming data and the text data is entered by using a keyboard.
It is used some key as special key to enter each data at the Easy Programming operation.

For example:
Push [DEPT1] key, if you want to set up DEPT1 items.
Push [%1] key, if you want to set up %1 item.
After that, every time it pushes [ST] key, a set up item changes with price,
text, programming ...
To change a programming content, it changes it using a numeric key.
As additional way, [00] key can be used as a incremental while an indicator lights on.
i.e. By pushing [00] key for a digit of parameters, a figure changes 0 3
1 3 2 3 ...
The data is changed by pushing [ST] key, and the display shows a content of the next item.
After that, the operator program the next set up item.
If a set up ends, it pushes [TL] key.
It shows the list of programmable data by this method (Direct key entry
type) on the next page.
It shows every set up item and example of display to the following.

<KEY SEQUENCE>
<DEPT>

There are follows.


KEY

Function

[DEPTn]
or
DEPT
code +
[DEPT#]

Text

(CHARACTER)

Price

(NUMERIC)

Entry type

(TOGGLE)

OPEN

Selection of TAX1

(TOGGLE)

(*1)

Selection of TAX2

(TOGGLE)

(*1)

Used for left moving entry (As left cursor key).

Selection of TAX3

(TOGGLE)

(*1)

Used for data decision entry.

Selection of TAX4

(TOGGLE)

(*1)

CONTENTS OF USE
DEPT

Used for parameter entry and character


code entry.

c Clear key ([CL])

Used for cancel entry.

d Point key ([.])

Used for decimal point entry and


right moving entry (As right cursor key).

e Multiplication key ([X])


f

Subtotal key ([ST])

g Finalization key ([TL])

Used for programming termination entry.

Entry type

Default
(MRS)

Step

a Numerical key (0, 1 to 9) Used for numerical number entry.


b Double-zero key ([00])

Programmable
data

key

DEPT.
xx

Registration type

(TOGGLE)

NORMAL

Group no.

(NUMERIC)

(*1) (*2)

10

Limitation digits

(NUMERIC)

Entry type

Default
(MRS)

(*1) DEPT01 - 10 : VAT 1 / Group 1


DEPT11 - 20 : VAT 2 / Group 1
DEPT21

: VAT 1 / G ro up
10

DEPT22 - 99 : VAT 1 / Group 1


(*2) Group 1-9

: (+) department

Group 10

: (-) department

Group 11

: (+) Hash department

Group 12

: (-) Hash department

<PLU>
Function
PLU

XE-A303 (V)

PROGRAM MODE

2 14

key
PLUn
or
PLU
code +
[PLU/
SUB]

Step

Programmable
data

Text

Price

(CHARACTER) PLU. xxxx


(NUMERIC)

Dept code

(NUMERIC)

01

Sign

(TOGGLE)

(+)

Type

(TOGGLE)

PLU

It shows every set up item and example of display to the following.

<(-)>
Function
(-)

key
(-)

Step

Programmable
data

Entry type

Default
(MRS)

(CHARACTER)

(*)

(NUMERIC)

Text

Unit price

Sign

(TOGGLE)

(-)

Item

(TOGGLE)

Enable

Subtotal

(TOGGLE)

Enable

Limitation digits

(NUMERIC)

<The details of ENTRY TYPE>


As it pushes [ST], a set up item advances the next step.
As it pushes [TL], and the set up data writes to the memory, and a set
up of the function ends.
Set up as it pushes other DIRECT PLU KEY on the way (exclude text
programming), and the set up data writes to the memory, a set up of the
next setting starts.
The guidance message is displayed at each programming step.
The following guidance messages are used for easy programming operation.

(*) Please refer function list. (Programming of function text)

<Programming for DEPT>


KEY ENTRY

<%n>
Function
%n

key
%n

Step

Programmable
data

Entry type

[DPT1]

Default
(MRS)

Text

(CHARACTER)

(*)

Rate

(NUMERIC)

0.00

Sign

(TOGGLE)

(-)

Item

(TOGGLE)

Enable

Subtotal

(TOGGLE)

Enable

% RATE halo

(NUMERIC)

100.00

OPERATER

0. 00

DEPT1 TEXT
DEPT1 CODE

0. 00

A text changes to ENTER [00]KEY.

0. 00

Message of ENTER TEXT is


displayed.

DEPT . 0 1
01
ENT ER [ 0 0 ] KEY
01

->[00]

ENT ER T EXT
01
DEPT . 0 1
01

068

(*) Please refer function list. (Programming of function text)


->066

Function
EX

key
EX

Step

Programmable
data

Entry type

Default
(MRS)

->[00]

Text

(CHARACTER)

(*)

Rate

(NUMERIC)

0.000000

OPEN RATE
ENTRY

(TOGGLE)

Enable

->EER
(_is set space)
->[ST]

PRESET RATE
ENTRY

(TOGGLE)

Enable

TAB

(NUMERIC)

->200

01

->[ST]

text

123

->[00]

Function
RA
PO
CH1
CH2
CR1
CR2

key
RA
PO
CH1
CH2
CR1
CR2

Step

Programmable
data

Text

2
3

Entry type

Default
(MRS)

200

DEPT ENT RY T YPE

(CHARACTER)

(*1)

Footer print on
receipt

(TOGGLE)

NO

Entry of amount
tendered

(TOGGLE)

Limitation digits

(NUMERIC)

->[00]
(*3)
->[ST]

(*2) Noncompulsory (Cash, check), inhibit (Credit)


(*3) 8 (CA, CH1, CH2, CR1, CR2), 9 (RA, PO)

->[00]

PRESET

DEPT ENT RY T YPE


01

(*1) Please refer function list. (Programming of function text)

OPEN

DEPT ENT RY T YPE


01

(*2)

I NH I B I T ED

DEPT ENT RY T YPE


01

->[00]

OPEN

S E L E CT OF T A X 1

Guidance message

T AX1

Current setting is displayed.

YES

NO

->[ST]

PROGRAM MODE

2 15

Guidance message

YES

Guidance message

SEL ECT OF T AX3


T AX3

XE-A303 (V)

NO

SEL ECT OF T AX2


T AX2

Current setting is displayed.


Guidance message

S E L E CT OF T A X 2
T AX2

->[00]

Guidance message

SEL ECT OF T AX1


T AX1

->[ST]

Guidance message
Current setting is displayed.

DEPT ENT RY T YPE


01

->[00]

Guidance message
Current setting is displayed.

PR I CE

0 1 OPEN & PRESET

<RA, PO, CH1, CH2, CR1, CR2>

If [00] key is entered and inputted text is addressed.


Then the cursor is blinking.

032

PR I CE

01

(*) Please refer function list. (Programming of function text)

069

BEER

01

066

BEPT . 0 1
01

Current DEPT1 text is displayed.


Then the cursor is blinking. (*)
Text code is inputted.

DEPT . 0 1
01

<EXCHANGE>

NOTE

1234567890123456

NO

KEY ENTRY
->[ST]

REG I ST .

NORMAL

ENT ER T EXT
0. 00

Current PLU1 text is displayed.

PL U. 0 0 0 1

01

0001

Guidance message

GROUP NO.

->066

11

080

0001

Guidance message

L I M I T D I G I TS
8

->[00]

Current setting is displayed.

066

BL U. 0 0 0 1
0001

Guidance message

L I M I T D I G I TS

->EER
(_is set space)

DEPT2 TEXT

DEPT . 0 2
0. 00

->[ST]

DEPT2 CODE
RETURN TO 1st STEP

ENT ER [ 0 0 ] KEY
02

->200

0. 00

076

PGM

DEPT1 SET UP TERMINATE

->[ST]

0. 00

0001

032

PR I CE

->02

->[ST]

OPERATER

NOTE

->[00]

DEPT5 TEXT

DEPT . 0 5
05

DEPT CODE

0. 00

ENTER [00]-KEY TO CHANGE


TEXT

05

0. 00

Message of ENTER TEXT is


displayed.

ENT ER T EXT
05

->[00]

->DRINK _

DR I NK
05

->[ST]

->[ST]

ENT ER DEPT #
02

S I GN
(+)

->[00]

->[00]

(- )

(+)

ENT ER PL U T YPE
PL U

->[ST]
Guidance message

SUBDEPT

ENT ER PL U T YPE
PL U

PLU2 TEXT / PLU CODE

PL U. 0 0 0 2
0002

0. 00

100

RETURN TO 1st STEP

ENT ER [ 0 0 ] KEY

->200

->[ST]

->[TL]
PRICE IS DECIDED

OPEN

PGM

PLU1 SET UP TERMINATE

(*) In case of text setting, you can use [X] or [.] key.
If you push [X] key, the cursor moves to the left. And if you push [.]
key, the cursor moves to the right.

OPEN
PGM

0. 00

0. 00

DEPT ENT RY T YPE


01

->[CL]

200

DEPT ENT RY T YPE


01

->[CL]

0002

PR I CE
05

Guidance message
Current setting is displayed.

ENT ER PL U T YPE

0001
032

Guidance message
Current setting is displayed.

S I GN

0001

Inputted DEPT no.


If you want to set PLU delete.
Please set 0.

S I GN

0001

068

PR I CE
05

01

0001

DEPT . 0 5
05

Guidance message/PLU code

ENT ER DEPT #

0001

0. 00

ENT ER [ 0 0 ] KEY

200

0001

1234567890123456

Guidance message
Current setting is displayed.
Guidance message

PR I CE

0001

<CANCEL OPERATION>

->[00]

100

0001

(*) In case of text setting, you can use [X] or [.] key.
If you push [X] key, the cursor moves to the left. And if you push [.]
key, the cursor moves to the right.

If [00] key is entered and inputted text is addressed.


Then the cursor is blinking.
text

BEER

0001

->[TL]

Then the cursor is blinking. (*)


Text code is inputted.

PL U. 0 0 0 1

0001

[DPT5]

Message of ENTER TEXT is


displayed.

Guidance message

GROUP NO.

02

KEY ENTRY

PLU CODE

0. 00

0001

01

->[ST]

->[00]

S I CS

01

->7

0. 00

ENT ER [ 0 0 ] KEY

Current setting is displayed.

T YPE

01

->[ST]

PLU1 TEXT

PL U. 0 0 0 1

0001
REG I ST .

NOTE

Guidance message

T YPE

01

->11

[PLU1]

OPERATER
1234567890123456

0001

01

->[ST]

KEY ENTRY

NO

01

->[00]

NOTE
Guidance message

SEL ECT OF T AX4


T AX4

->[ST]

<Programming for PLU>

OPERATER
1234567890123456

DEPT5 SET UP TERMINATE

0. 00

In this case, price (200) and text (DRINK) are not written to the preset
memory.
XE-A303 (V)

PROGRAM MODE

2 16

<PROGRAMMING FOR (-)>


KEY ENTRY
[(-)]

KEY ENTRY

OPERATER

NOTE

1234567890123456
(-)

PROGRAMM I NG

XX

0. 00

->[ST]
(-) PROGRAMMING
Function no.

->[00]

->[00]

0. 00

->[ST]
ENT ER T EXT
XX

0. 00

XX

->[ST]

253

Function no.

XX

->200

->[ST]

->90.00

->[ST]

SBT L ENABL E

% HAL O PROG.
100. 00

Guidance message
Current setting is displayed.

% HAL O PROG.
90. 00

% PROGRAMMING

%2 PROGRAMM I NG
0. 00

ENT ER [ 0 0 ] KEY
XX

I T EM D I SABL E

0. 00

Guidance message

E NT RY F OR S B T L

<PROGRAMMING FOR EXCHANGE>

SBT L D I SABL E

KEY ENTRY

E NT RY F OR S B T L
SBT L ENABL E

L I M I T D I G I TS
8

[EX]
Guidance message
Current setting is displayed.

OPERATER
1234567890123456

NOTE
EXCHANGE PROGRAMMING

EXCHANGE PROG.
XX

0. 00

ENT ER [ 0 0 ] KEY
L I M I T D I G I TS

XX

XX

[ST]

E NT RY F OR S B T L

XX

XX

->8

SBT L D I SABL E

XX

I T EM ENABL E

XX

->[ST]

[ST]

Guidance message

Guidance message

E NT RY F OR S B T L

ENT RY F OR I T EM

XX

->[00]

I T EM D I SABL E

XX

(+)

ENT RY F OR I T EM

ENT RY F OR I T EM

XX

S I GN

XX

->[00]

->[ST]

(- )

XX

I T EM ENABL E

XX

Guidance message

Guidance message

ENT RY F OR I T EM

XX

200

XX

->[00]

Message of ENTER AMOUNT


is displayed.
->[00]

S I GN

(+)

XX

ENT ER AMOUNT
XX

->[ST]

Current (-) text is displayed.


Function no.
->[ST]

ENT ER AMOUNT

S I GN

XX

->[00]
= (=- =)

(- )

XX

Function no.

NOTE
Guidance message

S I GN
XX

ENT ER [ 0 0 ] KEY
XX

OPERATER
1234567890123456

->[00]

ENT ER [ T L / NS] KEY

0. 00

ENT ER T EXT
XX

0. 00

Message of ENTER TEXT is


displayed.

0. 00

Current EXCH1 text is displayed.

EXCH1
XX

<PROGRAMMING FOR %>


KEY ENTRY
[ %1 ]

->[ST]

OPERATER
1234567890123456
%1 PROGRAMM I NG
XX

NOTE
->123.456789

% PROGRAMMING

->[00]
XX

0. 00

Message of ENTER TEXT is


displayed.
->[ST]

XX

253

ENT ER RAT E
XX

0. 00

OPEN RAT E ENT RY


OPEN D I SABL E

Guidance message

PRESET RAT E

PRESET RAT E

Message of ENTER RATE is


displayed.

PRESET D I SABL E

ENT ER RAT E
XX

OPEN ENABL E

Then the cursor is blinking.

->[ST]
->12.34

Guidance message

OPEN RAT E ENT RY

XX PRESET ENABL E

->[00]
->[ST]

Message of ENTER EX RATE


is displayed.

123. 456789

XX

Current % text is displayed.

=%= 1 =

Then the cursor is blinking.

ENT ER EX RAT E

XX

0. 00

ENT ER T EXT

0. 000000

XX

0. 00

->[ST]

->[00]

ENT ER EX RAT E
XX

ENT ER [ 0 0 ] KEY
XX

0. 00

XX
12. 34

XE-A303 (V)

PROGRAM MODE

2 17

Guidance message

T AB
2

KEY ENTRY
->3

OPERATER

->4

T AB
XX

->[ST]

KEY ENTRY

NOTE

1234567890123456

->[X]

Guidance message

ENT ER [ T L / NS] KEY

<PROGRAMMING FOR MEDIA KEYS & FUNCTION KEYS>


([RA], [PO], [CH1], [CH2], [CR1], [CR2])
OPERATER
CH1 PROGRAMM I NG
XX

0. 00

->[00]

ENT ER T EXT
0. 00

F OOT ER PR I NT
NO

AMOUNT T ENDERD
COMPUL SORY

AMOUNT T ENDERD

ENTER LINE

->1
In case of RA/PO setting, this
setting is skipped.

->[X]

In case of CR1/CR2 setting this


message is inhibit.

->SHARP

->[ST]

COMPUL SORY

NO.

Enter line no.


Numeric entry.
Enter line no.
Numeric entry.

=S=H=A Enter next key.


032 Numeric entry.

Text entry.

=S=H=A=R=P=

032 Numeric entry.

ENTER LINE

NO.
0 . 00

Guidance message

L I M I T D I G I TS

->[TL]

Enter line no.


Numeric entry.

P GM
0 . 00

L I M I T D I G I TS
0

CH2 PROGRAMM I NG

PROGRAMMING OF CLERK NAME

Guidance message

KEY ENTRY

0. 00

OPERATER
PGM

0. 00

->[]

CLERK NAME PROG.

2. GUIDANCE MESSAGE TYPE

<Sample operation & display>

ENTER CLERK NO.

PROGRAMMING OF FNCTION TEXT


OPERATER
1234567890123456

[ST] ->3

PGM
3
FUNC.

TEXT PROG.
3

ENTER FUNC. NO.


0

0 . 00

NOTE

->1

->[X]

FUNCTION TEXT PROGRAMMING TITLE

->TOMMY

Enter function no.


Numeric entry.

->[ST]

PROGRAM MODE

2 18

Numeric entry.

Text entry.
032 Numeric entry.

ENTER CLERK NO.


0 . 00

XE-A303 (V)

Enter clerk no.


Numeric entry.

076 Numeric entry.

TOMMY

01

CLERK NAME PROGRAMMING


TITLE

Enter next key.

CLERK 01

01

MODE
Numeric entry.

Enter clerk no.

ENTER CLERK NO.


1

MODE
Numeric entry.

NOTE

1234567890123456

[ST] ->5

Guidance message

ENT ER [ 0 0 ] KEY
XX

->[]

LOGO TEXT PROGRAMMING


TITLE

AMOUNT T ENDERD

XX

KEY ENTRY

4
NO.

ENTER LINE

XX

->

MODE
Numeric entry.

LOGO TEXT PROG.

XX

->[ST]

In case of RA/PO setting, this


setting is skipped.

PGM

XX

->0

->[]

YES

NON COMPUL SORY

->[ST]

[ST] ->4

Then the cursor is blinking.

NOTE

F OOT ER PR I NT

XX

->[00]

OPERATER
1234567890123456

0 . 00
XX

->[00]

Message of ENTER TEXT is


displayed.
Current CH1 text is displayed.

067

XX

->[ST]

P GM
0 . 00

KEY ENTRY

XX

->[00]

->[TL]

CH1 PROGRAMMING
(E ach media or fun ction key
messages is displayed)

Enter function no.


Numeric entry.

PROGRAMMING OF LOGO TEXT

CHE CK 1

->[ST]

ENTER FUNC. NO.

0. 00

XX

032 Numeric entry.

0 . 00

ENT ER [ 0 0 ] KEY
XX

Text entry.

DI FFER

NOTE

1234567890123456

Enter function no.


Numeric entry.

078 Numeric entry.

04

->[ST]

NOTE

Enter next key.

=N=E=T=1

04

->DIFFER

[CH1]

ENTER FUNC. NO.

0. 00

KEY ENTRY

OPERATER
1234567890123456

Enter clerk no.


Numeric entry.

KEY ENTRY

CLERK CODE DEFINITION

OPERATER
1234567890123456

->[TL]

NOTE
KEY ENTRY

P GM

OPERATER

[ST] ->16

0 . 00

P GM
16

FOREIGN CURRENCY SYMBOL PROGRAMMING


KEY ENTRY

OPERATER
1234567890123456

[ST] ->6

FOREIGN CURRENCY SYMBOL


PROGRAMMING TITLE

->[X]

Enter next key.


Numeric entry.

->99

032

Text entry.
Numeric entry.

->[ST]

032

Enter TL key.
Numeric entry.

->[TL]

6
_
01

->\

->[ST]

ENT ER [ T L / NS] KEY


0. 00

->[TL]

0 . 00

->1

F ORE I GN CURRENCY

->[X]

99

99
P GM

Enter TL KEY
Numeric entry.

AUTO KEY PROGRAMMING


OPERATER

NOTE

0. 0 0

Auto key programming title.


Numeric entry.

P GM

DEPT1 entry

A U TO K E Y P ROG.

->[DPT1]
MODE
Numeric entry.

NOTE

1234567890123456

01

->[1]
TAX RATE PROGRAMMING TITLE

T AX RAT E PROG.

Numeric entry.
CLERK CODE DEFINITION

C LERK NO.

0 . 00

[AUTO1]

PGM

C LERK CODE

01

TAX RATE PROGRAMMING

[ST] ->9

0 . 00

01

KEY ENTRY

1234567890123456

Numeric entry.
CLERK CODE DEFINITION

C LERK CODE
01

0. 00

KEY ENTRY

CL ERK NO.
1

PGM

OPERATER

MODE
Numeric entry.
CLERK CODE DEFINITION

CL ERK NO.

NOTE
MODE
Numeric entry.

PGM
6

->[]

->[X]

NOTE

1234567890123456

P GM
1

1 key entry.

02

->[0]
ENT ER T AX NO.
0. 00

->1

->[X]

Enter tax no.


Numeric entry.

0. 00

Enter tax rate.


Numeric entry.

P GM
1

15

P GM
1

->[AUTO1]
ENT ER T AX RAT E

ENT ER L OWER T AX
1

->10

0. 00

ENT ER L OWER T AX
1

->[ST]

10

ENT ER T AX NO.
0. 00

->[TL]

DEPT2 entry

05

E N T E R [ T L / NS ] K EY

Text entry.
Numeric entry.

0 . 00

->[TL]
->[X]

0 key entry.

04

->[DPT2]
ENT ER T AX RAT E

0 key entry.

03

->[0]
Enter tax no.
Numeric entry.

ENT ER T AX NO.

->15

P GM
1

Enter TL key.
Numeric entry.

P GM

Enter LOWER TAX LIMIT


Numeric entry.

0 . 00

VARIOUS PROGRAMMING

Text entry.
Numeric entry.

KEY ENTRY

Enter next key.


Numeric entry

[ST] ->AB

OPERATER
P GM
AB

->[X]

P GM
0 . 00

GU I D A NC E T E X T
0 . 00

->(NK)

GU I D A NC E T E X T
NK

->[ST]

E N T E R [ T L / NS ] K EY
0 . 00

->[TL]

P GM
0 . 00

XE-A303 (V)

PROGRAM MODE

2 19

NOTE

1234567890123456

MODE
Numeric entry.
Guidance text. (*)
Job No.
Guidance text.
Job No. Programming data.
Enter TL key.

(*) GUIDANCE TEXT


JOBNO.

TRAINING MODE TEXT PROGRAMMING


GUIDANCE TEXT

JOB TITLE

MACHINE No.

MACH I N E NO.

CONSECUTIVE No.

C ONSEC U T I V E NO.

FUNCTION SELECT

F UNCT I ON S E L E CT

PRINT FORMAT

PR I NT FORMAT

RECEIPT PRINT FORMAT

RCPT PRT FORMAT

EURO FUNCTIONS

EURO FUNCT I ONS

10

POWER SAVING

POWER SAV I NG

11

LOGO PRINTING

LOGO PR I NT I NG

12

EURO Programming

EURO PROG.

13
14

KEY ENTRY

1234567890123456

The date of exchanging the between


LOCAL and EURO
The Time (hour only) of exchanging the
currency between LOCAL and EURO

OPERATER

[ST] ->87

PGM
87

->[.]
8 7.

0 42

->TRAINING

TRA I N I NG
0 32

->[ST]

EURO EX T I ME

SENTINEL (CID HALO)

SENT I NEL AMOUN T

21

CHECK CASHING (HALO)

CHECK CASH HAL O

22

CHECK CHANGE (HALO)

CHECK CHNG HAL O

35

USB TIME OUT

USB T I ME OUT

50

THERMAL PRINTER DENSITY CONTROL

PR I NT ER DEN S I T Y

61

OTHERS1 PROGRAMMING

OT HERS1 PROG.

62

OTHERS2 PROGRAMMING

OT HERS2 PROG.

63

OTHERS3 PROGRAMMING

OT HERS3 PROG.

64

OTHERS4 PROGRAMMING

OT HERS4 PROG.

65

OTHERS5 PROGRAMMING

OT HERS5 PROG.

66

OTHERS6 PROGRAMMING

OT HERS6 PROG .

67

OTHERS7 PROGRAMMING

OT HERS7 PROG.

68

OTHERS8 PROGRAMMING

OT HERS8 PROG.

69

OTHERS9 PROGRAMMING

OT HERS9 PROG.

70

OTHERS10 PROGRAMMING

OT HERS1 0 PR OG.

71

GT2 PROGRAMMING

GT 2 P R OG.

In a moment, display for text


programming will change.
CHARACTER

** T RA I N I NG **

EURO EX DATE

20

MODE
Numeric entry.
TRAINING MODE TEXT PROGRAMMING

TRA I N I NG T EX T

->

NOTE

1234567890123456

Enter TL key.

E N T E R [ T L / NS ] K EY
0 . 00

->[TL]

P GM
0 . 00

TEXT CHANGING (To Default text)


KEY ENTRY

OPERATER

[ST] ->88

PGM
88

->[X]

LA NGU A GE CHANGE
88

->1

MODE
Numeric entry.
TEXT CHANGING (To default text).
TITLE

LA NGU A GE CHANGE
1

->[TL]

NOTE

1234567890123456

Text no.
In English THANK YOU.

V I E L E N D AN K
1

72

GT3 PROGRAMMING

GT 3 P R OG.

76

GENERAL Z1 RESET REPORT COUNTER

Z 1 R E S E T C OU N T ER

P GM

77

GENERAL Z2 RESET REPORT COUNTER

Z2 RE S E T C OUNT ER

0 . 00

86

TRAINING CLERK PROGRAMMING

T R A I N I NG C LE R K

Resetting of all counter and totalizer


DOMESTIC CURRENCY SYMBOL PROGRAMMING
KEY ENTRY

OPERATER
1234567890123456

[ST] ->85

P GM
85

->[.]

DOM.

C URREN CY
85.

->

KEY ENTRY

NOTE

[ST] ->89

MODE
Numeric entry.

->[X]

DOMESTIC CURRENCY SYMBOL .


PROGRAMMING TITLE.

->[TL]

E N T E R [ T L / NS ] K EY

Guidance text.
DIGITS
Enter TL key.

0 . 00

->[TL]

P GM
0 . 00

0 32

->[ST]

MEMORY RESETT I NG
89

PGM
89

0 32

->224 ->[00]

OPERATER
1234567890123456

P GM
0 . 00

XE-A303 (V)

PROGRAM MODE

2 20

NOTE
MODE
Numeric entry.
Resetting of all counter and
totalizer TITLE.

CHAPTER 3. OP X/Z, X1/Z1, X2/Z2 MODE


In general, the following sales reports are available:

[Purpose]

1) OP X/Z reports (individual clerk reports)

The above reports are each used to check sales data. The standard
purposes of taking these reports are as follows:

2) X1/Z1 reports (Daily sales total X and Z reports)

OP X/Z reports: These reports are taken by operators in order to report


their own sales data.

3) X2/Z2 reports (Periodic total X and Z reports)


4) Flash-read reports (Display sales amount)

X1/Z1 reports: These reports are taken by the supervisor or manager


in order to check and report daily sales totals at that
point.

In addition to the above reports that are to be used, reports for checking
the program are also available.

X2/Z2 reports: These reports are taken by the owners or manager in


order to check and report periodic (weekly or monthly)
totals.
Flash-read:

These reports are taken by the owner or manager in


order to check and display sales totals at that point.

[Operation]
In the table below those reports marked with a circle o can be executed.

PRINTING REPORT
MODE
REPORT NAME

KEY ENTRY

OPX/Z

X1/Z1

X2/Z2

DATA FOR READING

X1

Z1

X2

Z2

GENERAL

[TL/NS]

----

----

DEPARTMENT

[DEPT#]

----

----

----

----

*1

DEPT IND. GROUP

NK 3 [x] 3[DEPT#]

----

----

----

----

DEPT GROUP TOTAL

[0] 3 [x] 3[DEPT#]

----

----

----

----

PLU BY RANGE

[PLU]

----

----

PLU CODE

PLU BY DEPT

NK 3 [DEPT SHIFT] 3[PLU]

----

----

----

----

DEPT. CODE

GROUP NO.

*1, *2

TRANSACTION

[1] 3 [TL/NS]

----

----

----

----

TL-ID

[2] 3 [TL/NS]

----

----

----

----

CLERK (ALL)

[CLK#]

----

----

*1

CLERK (INDIVISUAL)

[CLK#]

----

----

----

----

*1, *3

HOURLY (ALL)

[#/TM/ST]

----

----

----

----

HOURLY (RANGE)

[#/TM/ST]

----

----

----

----

----

DAILY NET

[#/TM/ST]

----

----

----

----

*1
TIME (HOUR) *1, *5
*1

FLASH READING REPORT


MODE
REPORT NAME

KEY ENTRY

OPX/Z

X1/Z1

X2/Z2

DATA FOR READING

X1

Z1

X2

Z2
*4

DEPARTMENT

[DPTn]
or [DEPT SHIFT] 3 [DPTn]
or NK 3 [DEPT#]

----

----

----

----

----

CID

[X]

----

----

----

----

----

*4

SALES TOTAL

[TL/NS]

----

----

----

----

----

*4

DEPT CODE

OTHERS OPERATION
MODE
REPORT NAME

JOB#

OPX/Z

EURO CHARGE

800

XE-A303 (V)

X1/Z1

X1

Z1

X2

Z2

----

----

----

----

OP X/Z, X1/Z1, X2/Z2 MODE

31

X2/Z2

DATA FOR READING


*6

MODE:

X : Daily operater X report

Z : Daily operater Z report

X1 : Daily X report

Z1 : Daily Z report

X2 : Periodic X report

Z2 : Periodic Z report

[Action]
Individual counters for the following Z reports are incremented when
those reports are printed.
1) General daily total report (Z1)

(X report): The corresponding data is held in the ECR.

2) General periodic total report (Z2)

(Z report): The corresponding data is cleared in the ECR.

[Additional function]

Stop of printing reports (Report cancel function):


This ECR has the function of report stopping for PLU report.

(1) Overflow mark


If the amount or quantity in any totalizer other than GT to be printed
on X or Z reports exceeds a programmed limit, the indication mark
(overflow mark) is printed for the totalizer concerned.
The overflow mark may be printed even if a totalizer does not reach
the maximum amount. This occurs, for example, when the amount
or quantity in the totalizer gets smaller than the maximum amount
due to the entry of a negative amount after the overflowing of the
totalizer. This means that when the totalizer overflows once, the
overflow mark (for example,"!!") is printed.

*1 To read respective reports, it is necessary to follow the procedure


below.

Reading
(X report)
KEY

Resetting
(Z report)

(2) MODE TITLE


Each report prints a MODE TITLE at a header of report.
The Report Titles are as follows.

*2 PLU code range can be specified by entering the start and end
numbers according to the following procedure.
When specifying a single PLU code, the start number has only to be
entered.

All
Reading
XXXX
End NO.

XXXX
Start NO.

PLU

Resetting

*OPX*

OPZ report

*OPZ*

X1 report

*X 1*

Z1 report

*Z 1*

X2 report

*X 2*

Z2 report

*Z 2*

(3) Report cancel function


It can be cancelled by turned the mode switch to MGR position
while the data is printed. (In this case, the contents of memory are
not cleared.)

*3 The clerk code does not need to enter at the OPX/Z mode.
In OPX/Z mode, it is issued the report of the assigned clerk.
*4 Reading display only.
The displayed amount can be cleared by [CL] key..

KEY
(Display amount)

OPX report

<Print sample of Report cancel>


:
:

CL

(Display initialize)

* * * * * * * *
123456789012345678901234567890

*5 Hourly range can be specified by entering the start and end hour
according to the following procedure.
When specifying a single hour, the start hour has only to be entered.

Reading

ALL
XX
Start

@/FOR

XX
End

#/TM/ST

Resetting

*6 To read respective contents, it is necessary to follow the procedure


below.

Reading
EURO STATUS

JOB#

TL

Executing

XE-A303 (V)

OP X/Z, X1/Z1, X2/Z2 MODE

32

1 the report cancel symbol

CHANGING EURO FUNCTION (Z2 MODE JOB)


This job is own to be able to be changed easily from local currency system to EURO currency system in X2/Z2 mode.

[Action]

(Reading the current EURO status)

1) Issue General Z1 report.

It is executed some of below JOBs which is needed for each status.


2) Issue General Z2 report.

TL

(X2/Z2 mode) 800

3) Clear GT1/2/3 and Training GT.


4) Convert the unit price of DEPT/PLU from LOCAL currency to EURO.
If new unit price is over the max digits, its price is set as 0.00.

(Changing EURO Function)

(X2/Z2 mode) 800

Y: 1

= EURO STATUS (B)

= EURO STATUS (C)

= EURO STATUS (D)

5) Convert the HALO amount and HALO digits from LOCAL currency
to EURO.
If new HALO amount is over the max digits, its price is set as 0.00.

TL

6) Change PGM function EX1 AMOUNT PRINTING FOR TOTAL


AND CHANGE YES/NO.
7) Change PGM function EX1 CALCULATTION METHOD DIVISION/
MULTIPLICATION.

About EURO STATUS are shown the following pages.


It is executing automatically to change from status (A) to status (B), (C), (D).
Selectable type is one of below 4 types.
And the selectable type is decided as below for each status.

8) Set Domestic currency symbol as EURO SYMBOL.


9) Set Domestic TAB as 2.
10) Set EX1 currency symbol as the suitable data.
11) Set EX1 TAB as the suitable data.
12) Set Rounding SYSTEM (Denmark/Sweden/Normal) as Normal.

Selectable STATUS

CURRENT STATUS
4

(A)

(B)

(C)

(D)

(A)

------

(B)

------

------

(C)

------

------

------

(D)

------

------

------

------

13) Set Rounding up/down of the unit digits of AMOUNT" as No.


14) Set Lowest digit entering limitation of item as Arbitrary.
15) Set Lowest digit entering limitation of payment as Arbitrary.
16) Set Difference memory as No.
17) Set Rounding of foreign currency for EX as Round off (4-DOWN,
5-UP). (EURO Regulation)
Notes:

Marked u is selectable

a) This JOB cannot set below additional EURO function automatically.


Below items must be set by each PGM JOB after this job.
(1) EX1 RATE
(2) CHECK, CREDIT operation for EX1

Yes/No

b) When the unit price is converted, the rounding method of EURO


currency is fixed as Round off (4-DOWN, 5-UP).
[EURO Regulation]

[Selecting type and its action]


Current status (A) :
Selected STATUS

CURRENT STATUS (A)

(B)

(C)

(D)

1) General Z1 report

ISSUE

ISSUE

ISSUE

2) General Z2 report

ISSUE

ISSUE

ISSUE

3) GT1/2/3

------

CLEAR

CLAER

4) Convert the unit price of DEPT/PLU

------

CONVERTING

CONVERTING

5) Convert the HALO amount and HALO digits


6) EX1 AMOUNT PRINTING FOR TOTAL AND CHANGE
7) EX1 CALCULATTION METHOD

------

CONVERTING

CONVERTING

YES

YES

NO

DIVISION

MULTI.

MULTI.

8) Domestic currency symbol

------

[EURO]

[EURO]

9) Domestic TAB

------

[EURO]

The Current "Domestic


currency symbol"

------

11) EX1 TAB

"2"

The Current Domestic TAB

------

12) Rounding SYSTEM (Denmark/Sweden/Normal)

------

Normal

Normal

13) Rounding up/down of the unit digits of AMOUNT

------

No

No

14) Lowest digit entering limitation of item

------

Arbitrary

Arbitrary

15) Lowest digit entering limitation of payment

------

Arbitrary

Arbitrary

16) Difference memory

------

No

No

10) EX1 currency symbol

17) Rounding of foreign currency for EX

ROUND OFF (4DOWN-5UP) ROUND OFF (4DOWN-5UP) ROUND OFF (4DOWN-5UP)


Marked ------ is remaining the current data.
XE-A303 (V)

OP X/Z, X1/Z1, X2/Z2 MODE

33

Current status (B):


Selected STATUS

CURRENT STATUS (B)


1) General Z1 report

(C)

(D)

ISSUE

ISSUE

2) General Z2 report

ISSUE

ISSUE

3) GT1/2/3

CLEAR

CLAER

4) Convert the unit price of DEPT/PLU

CONVERTING

CONVERTING

5) Convert the HALO amount and HALO digits

CONVERTING

CONVERTING

YES

YES

7) EX1 CALCULATTION METHOD

6) EX1 AMOUNT PRINTING FOR TOTAL AND CHANGE

MULTI.

MULTI.

8) Domestic currency symbol

[EURO]

[EURO]

The Current "Domestic


currency symbol"

[SPACE]

9) Domestic TAB
10) EX1 currency symbol
11) EX1 TAB

The Current "Domestic TAB"

------

Normal

"Normal"

12) Rounding SYSTEM (Denmark/Sweden/Normal)


13) Rounding up/down of the unit digits of AMOUNT

No

"No"

14) Lowest digit entering limitation of item

Arbitrary

Arbitrary

15) Lowest digit entering limitation of payment

Arbitrary

Arbitrary

No

No

16) Difference memory


17) Rounding of foreign currency for EX

ROUND OFF (4DOWN-5UP)

ROUND OFF (4DOWN-5UP)

Marked ------ is remaining the current data.


Current status (C):
Selected STATUS

CURRENT STATUS (C)

(D)

1) General Z1 report

ISSUE

2) General Z2 report

ISSUE

3) GT1/2/3, Training GT

------

4) Convert the unit price of DEPT/PLU

------

5) Convert the HALO amount and HALO digits

------

6) EX1 AMOUNT PRINTING FOR TOTAL AND CHANGE

NO

7) EX1 CALCULATTION METHOD

MULTI.

8) Domestic currency symbol

[EURO]

9) Domestic TAB

10) EX1 currency symbol

[SPACE]

11) EX1 TAB

------

12) Rounding SYSTEM (Denmark/Sweden/Normal)

------

13) Rounding up/down of the unit digits of AMOUNT

------

14) Lowest digit entering limitation of item

------

15) Lowest digit entering limitation of payment

------

16) Difference memory

------

17) Rounding of foreign currency for EX

ROUND OFF (4DOWN-5UP)


Marked ------ is remaining the current data.

XE-A303 (V)

OP X/Z, X1/Z1, X2/Z2 MODE

34

COPYRIGHT 2006 BY SHARP CORPORATION


All rights reserved.
Printed in Japan.
No part of this publication may be reproduced,
stored in a retrieval system, or transmitted.
In any form or by any means,
electronic, mechanical, photocopying, recording, or otherwise,
without prior written permission of the publisher.

SHARP CORPORATION
Information and Communication Systems Group

Quality Assurance Department


Yamatokoriyama, Nara 639-1186, Japan
2006 August Printed in Japan t

You might also like