LFR/en/version: 08 / 2007
Service Manual
11 - 2
MJFCIFSS
Service Manual
bar
Nm
LFR/en/version: 08 / 2007
kW
cm
l/min
bar
MJFCIFSS
11 - 3
Service Manual
To simplify the oil refilling procedure, the drain of major components on the uppercarriage are centrally connected via a service center compartment.
They are :
the engine oil
the splitterbox
the two swing gears
the fuel tank
the hydraulic tank
11 - 4
MJFCIFSS
LFR/en/version: 08 / 2007
Service Manual
LFR/en/version: 08 / 2007
The service trap is electrically driven. It can be extended and retracted via the control box E1022_2, which is
installed at the bottom of the access ladder.
MJFCIFSS
11 - 5
Service Manual
Schematics
11.1Schematics
LFR/en/version: 08 / 2007
11.1.1Hydraulic
11 - 6
MJFCIFSS
Service Manual
LFR/en/version: 08 / 2007
Schematics
MJFCIFSS
11 - 7
Service Manual
Schematics
Description
CLL
CLS
CP3
COP1
COP2
CSS
M10
P12
PRV
RCL
SP
Y64
Y65
Y66
Y67
Y68
Y69
Y70
Y71
LFR/en/version: 08 / 2007
Pos.
11 - 8
MJFCIFSS
Service Manual
LFR/en/version: 08 / 2007
Schematics
MJFCIFSS
11 - 9
Service Manual
Schematics
LFR/en/version: 08 / 2007
11.1.2Electric
11 - 10
MJFCIFSS
Service Manual
Pos.
Description
Pos.
Description
A1008.1
A1008.4
A1008.5
A1020
K110
K113
K137
B92
B100
B101
B105
B106
KT9
M10
S122
E16.5
E21
E22.4
E57
E1003
E1005
E1022.1
E1022.2
E1037
E1039.1
E1039.2
S125
S126
S127
S141
S155
S156
S157
S158
S159
S160
S161
S162
F138
F139
F140
F144
F163
F164
X134
X310
X320
H15.4
H67
H68
Y64
Y65
Y66
Y67
Y68
Y69
Y70
Y71
LFR/en/version: 08 / 2007
H69
H70
MJFCIFSS
11 - 11
Service Manual
Location of components
11.2Location of components
LFR/en/version: 08 / 2007
11 - 12
MJFCIFSS
Service Manual
LFR/en/version: 08 / 2007
MJFCIFSS
11 - 13
Service Manual
LFR/en/version: 08 / 2007
Location of components
11 - 14
MJFCIFSS
Service Manual
LFR/en/version: 08 / 2007
MJFCIFSS
11 - 15
Service Manual
Location of components
LFR/en/version: 08 / 2007
11 - 16
MJFCIFSS
Service Manual
LFR/en/version: 08 / 2007
MJFCIFSS
11 - 17
Service Manual
Functional description
11.3Functional description
11.3.1Electrical part
11.3.1.1Ladder
Ladder up motion
The ladder up motion is driven electrically via a remote control, or via the push button S155 on the control box
E1022-1.
The solenoid valve Y64 is supplied via the plate A1008-4 and E1037.
The relay K110 for M10 is supplied via the plate A1008-5.
If the temperature switch B92 is opened (the temperature of the motor M10 is too high), nothing happens.
If the temperature switch B92, is closed, the motor M10 is supplied and it drives the pump P12. The
rotating cylinder RCL of the ladder is supplied. The ladder goes up.
The relay B02 in the plate A1008-5 is switched and then the warm light alarm E22-4 and the horn alarm
H15-4 are in motion while the button S155 is pushed.
When the ladder is coming near its upper position, its movement is automatically broken thanks to a system included in the rotating cylinder (see components).
The proximity switch (ladder in upper position) is not in motion.
The indicator H67 (ladder not in upper position) is on.
The switch S156 (ladder locking) is not supplied.
The proximity switch B106 (ladder locked) is not in motion.
The indicator H68 (ladder not locked) is on.
No current is sent to the plate A1008.5 (the excavator can not be actuated).
Ladder locking
As the proximity switch B105 is in motion, the solenoid valve Y65 is supplied via the plate A1008-4 and
E1037 (as the ladder is in upper position, it can be locked).
The relay K110 for M10 is supplied via the plate A1008-5 and the connector X134.
If the temperature switch B92 is opened (the tempereture of the motor M10 is too high), nothing happens.
If the temperature switch B92 is closed, the motor M10 is supplied and it drives the pump P12. The
locker cylinder CLL of the ladder is supplied. The ladder is locking.
The relay B02 in the plate A1008-5 is switched and then the warm light alarm E22-4 and the horn alarm
H15-4 are in motion while the button S156 is pushed.
The proximity switch B106 (ladder locked) is not in motion.
The indicator H68 (ladder not locked) is on.
No current is sent to the plate A1008.5 (the excavator can not be actuated).
11 - 18
MJFCIFSS
LFR/en/version: 08 / 2007
The ladder locking is driven electrically via a remote control, or via a the push button S156 on the control box
E1022-1 (see connection box E1022.1 (ladder control)).
Service Manual
Ladder locked
When the ladder is locked, the proximity switch B106 is in motion.
The relay ST1 in the plate A1008-4 is switched.
The indicator H68 (ladder not locked) is switched off.
A current is sent to the plate A1008.5.
The relay B02 in the plate A1008-4 is switched.
The switch S158 (ladder descending motion) is not supplied.
The solenoid valve Y67 which controls the ladder descending motion can not be supplied anymore
: as ladder is in locked position, it can not go down.
Ladder unlocking
The ladder unlocking is driven electrically via a remote control, or via the push button S157 on the control box
E1022-1 (see connection box E1022.1 (ladder control)).
The solenoid valve Y66 is supplied via the plate A1008-4 and E1037.
The relay K110 for M10 is supplied via the plate A1008-5 and the connector X134.
If the temperature switch B92 is opened (the temperature of the motor M10 is too high), nothing happens.
If the temperature switch B92 is closed, the motor M10 is supplied and it drives the pump P12. The
locker cylinder CLL of the ladder is supplied. The ladder is unlocking.
The relay B02 in the plate A1008-5 is switched and then the warn light alarm E22-4 and the horn alarm
H15-4 are in motion while the button S157 is pushed.
Ladder unlocked
The proximity switch B106 is not in motion anymore.
The relay ST1 in the plate A1008-4 is not switched anymore.
The indicator H68 is switched on.
No current is sent to the plate A1008.5 (the excavator can not be actuated).
The relay B02 in the plate A1008-4 is not switched anymore.
The solenoid valve Y67 that controls the ladder descending motion can be supplied.
LFR/en/version: 08 / 2007
The ladder descending motion is driven electrically via a remote control, or via the push button S158 on the
control box E1022-1 (see connection box E1022.1 (ladder control)).
As the proximity switch B106 is not in motion, the solenoid valve Y67 is supplied via the relay B02 in the
plate A1008-4 and E1037 (as the ladder is not locked, it can be lowered).
The relay K110 for M10 is supplied via the plate A1008-5 and the connector X134.
If the temperatue switch B92 is opened (the temperature of the motor M10 is too high), nothing happens.
If the temperature switch B92 is closed, the motor M10 is supplied and it drives the pump P12. The
rotating cylinder RCL of the ladder is supplied. The ladder goes down.
The relay B02 in the plate A1008-5 is switched and then the warn light alarm E22-4 and the horn alarm
H15-4 are in motion while the button S158 is pushed.
When the ladder is coming near its low position, its movement is automatically slowed down thanks to a
system included in the rotating cylinder (see components).
The proximity switch B105 (ladder in upper position) is not in motion.
The indicator H67 (ladder not in upper position) is on.
The switch S156 (ladder locking) is not supplied.
The proximity switch B106 (ladder locked) is not in motion.
The indicator H68 (ladder not locked) is on.
No current is sent to the plate A1008.5 (the excavator can not be actuated).
MJFCIFSS
11 - 19
Service Manual
Functional description
11.3.1.2Service trap
Trap unlocking
The trap unlocking is driven electrically via a remote control, or via the push button S161 on the control box
E1022-2 (see connection box E1022.2 (trap control)).
The solenoid valve Y70 is supplied via the plate A1008-5 and E1037.
The relay K110 for M10 is supplied via the plate A1008-5 and the connector X134.
If the temperature switch B92 is opened (the temperature of the motor M10 is too high), nothing happens.
If the temperature switch B92 is closed, the motor M10 is supplied and it drives the pump P12. The
locker cylinder CLS of the trap is supplied. The trap is unlocking.
The relay B02 in the plate A1008-5 is switched and then the warn light alarm E22-4 and the horn alarm
H15-4 are in motion while the button S161 is pushed.
Trap unlocked
The proximity switch B101 is not in motion anymore.
The relay ST1 in the plate A1008-5 is not switched anymore.
The indicator H70 (service trap not locked) is switched on.
The current issued of the relay ST1 in the plate A1008-4 can not be sent to the FSG plate A1020
(the excavator can not be actuated).
The relay K137 in E1003 is not switched anymore.
The solenoid valve Y71, which controls the service trap descending motion, can be supplied.
As the proximity switch B101 is not in motion, the relay K137 is not switched and then the solenoid valve
Y71 is supplied via the relay K137 and E1037 (as the trap is unlocked, it can be lowered).
The relay K110 for M10 is supplied via the plate A1008-5 and the connector X134.
If the temperature switch B92 is opened (the temperature of the motor M10 is too high), nothing happens.
If the temperature switch B92 is closed, the motor M10 is supplied and it drives the pump P12. The
cylinder CSS of the trap is supplied. The trap goes down.
The relay B02 in the plate A1008-5 is switched and then the warn light alarm E22-4 and the horn alarm
H15-4 are in motion while the button S162 is pushed.
When the trap is coming near its low position, its movement is automatically slowed down thanks to a system included in the cylinder (see components).
The proximity switch B100 (trap in upper position) is not in motion.
The indicator H69 (trap not in upper position) is on.
The switch S160 (trap locking) is not supplied.
The service trap lightening E57 is on.
The proximity switch B101 (trap locked) is not in motion.
The indicator H70 (trap not locked) is on.
The current issued of the relay ST1 in the plate A1008-4 can not be sent to the FSG plate A1020
(the excavator can not be actuated).
Trap up motion
The trap up motion is driven electrically via a remote control, or via the push button S159 on the control box
E1022-2 (see connection box E1022.2 (trap control)).
The solenoid valve Y68 is supplied via the plate A1008-5 and E1037.
The relay K110 for M10 is supplied via the plate A1008-5 and the connector X134.
If the temperature switch B92 is opened (the temperature of the motor M10 is too high), nothing happens.
11 - 20
MJFCIFSS
LFR/en/version: 08 / 2007
The trap descending motion is driven electrically via a remote control, or via the push button S162 on the control
box E1022-2 (see connection box E1022.2 (trap control)).
Service Manual
If the temperature switch B92 is closed, the motor M10 is supplied and it drives the pump P12. The
cylinder CSS of the trap is supplied. The trap goes up.
The relay B02 in the plate A1008-5 is switched and then the warn light alarm E22-4 and the horn alarm
H15-4 are in motion while the button S159 is pushed.
When the trap is coming near its upper position, its movement is automatically slowed down thanks to a
system included in the cylinder (see components).
The proximity switch B100 (trap in upper position) is not in motion.
The indicator H69 (trap not in upper position) is on.
The switch S160 (trap locking) is not supplied.
The service trap lightening E57 is on.
The proximity switch B101 (trap locked) is not in motion.
The indicator H70 (trap not locked) is on.
The current issued of the relay ST1 in the plate A1008-4 can not be sent to the FSG plate A1020
(the excavator can not be actuated).
Trap locking
The trap locking is driven electrically via a remote control, or via the push button S160 on the control box
E1022-2 (see connection box E1022.2 (trap control)).
As the proximity switch B100 is in motion, the solenoid valve Y69 is supplied via the plate A1008-5 and
E1037 (if the trap is not in upper position, B100 is not in motion and Y69 can not be supplied).
The relay K110 for M10 is supplied via the plate A1008-5 and the connector X134.
If the temperature switch B92 is opened (the temperature of the motor M10 is too high), nothing happens.
If the temperature switch B92 is closed, the motor M10 is supplied and it drives the pump P12. The
locker cylinder CLS of the trap is supplied. The trap is locking.
The relay B02 in the plate A1008-5 is switched and then the warn light alarm E22-4 and the horn alarm
H15-4 are in motion while the button S160 is pushed.
Trap locked
LFR/en/version: 08 / 2007
MJFCIFSS
11 - 21
Service Manual
Functional description
11.3.1.3Safety measure
The excavator can only be operated if the ladder and the service trap are locked in their upper position. It
means that if the proximity switches B106 and B101 are not in motion, no movements are allowed.
When the ladder is locked, the proximity switch B106 is in motion. The relay ST1 in the plate A1008-4 is
switched and sends a current to the plate A1008.5.
When the trap is locked, the proximity switch B101 is in motion. The relay ST1 in the plate A1008-5 is
switched. The current issued of the relay ST1 in the plate A1008-4 can now be sent to the FSG plate
A1020.
While the FSG plate A1020 receives no current, no movements are possible.
This safety measure can be bypassed momentarily by pushing and holding the switch S122.
LFR/en/version: 08 / 2007
By pushing S122, a current will be directly sent to the FSG plate A1020 and the excavator will be able to be
operated.
11 - 22
MJFCIFSS
Service Manual
11.3.2Hydraulic part
The hydraulic part consists in :
The pressure relief valve limits the pressure value at 110 bar in order to prevent the mechanical damages.
This figure shows the hydraulic schematic of the ladder descending motion.
LFR/en/version: 08 / 2007
The pump P12 supplies the port B of the rotating cylinder RCL threw a non-return valve. Then the oil flows to
the brake valve. While the pressure issued of the rotating cylinder is not sufficiency, the oil can not flow to the
collecting pipe CP3 : the ladder does not move. When the pressure is sufficiently strong, the brake valve allows
to control the speed of the ladder down motion and so to prevent that the ladder falls abruptly due to its weight.
MJFCIFSS
11 - 23
Service Manual
Functional description
LFR/en/version: 08 / 2007
The pump P12 supplies the port A of the rotating cylinder RCL threw a non-return valve. Another part of the oil
opens the non-return valve. The oil flows out the rotating cylinder and flows to the collecting pipe CP3 through
the non-return valve, which has been opened by the high pressure.
11 - 24
MJFCIFSS
Service Manual
11.4Troubleshooting
11.4.1Ladder
Problem : the ladder does not go up.
-
When you press the button S155 that controls the ladder up motion, the ladder doesnt go up.
Does the motor M10 work?
N
-
Verify if the led corresponding to the solenoid valve Y64 on the connection box E1037 is on when
you push the button S155.
N
-
The solenoid valve Y64 is defective or is not supplied (broken wire between E1037 and Y64).
Control the adjustment value of the pressure control valve. Is the value set at 110 bar?
N
-
Adjust the pressure control valve (see adjustment of the pressure control valve).
LFR/en/version: 08 / 2007
The button S155 or the wire between S155 and E1037 is broken.
MJFCIFSS
11 - 25
Service Manual
Troubleshooting
When you press the button S156 that controls the ladder locking, the ladder gets not locked.
Is the indicator H67 (ladder not in upper position) off?
N
-
Push the button S156 until the ladder has reached its top position.
The ladder can now be locked.
N
-
Verify if the led corresponding to the solenoid valve Y65 on the connection box E1037 is on when
you push the button S156.
N
-
The solenoid valve Y65 is defective or is not supplied (broken wire between E1037 and Y65).
Control the adjustment value of the pressure control valve. Is the value set at 110 bar?
N
-
Adjust the pressure control valve (see adjustment of the pressure control valve).
LFR/en/version: 08 / 2007
11 - 26
MJFCIFSS
Service Manual
When you press the button S157 that controls the ladder unlocking, the ladder gets not unlocked.
Does the motor M10 work?
N
-
Verify if the led corresponding to the solenoid valve Y66 on the connection box E1037 is on when
you push the button S157.
N
-
The solenoid valve Y66 is defective or is not supplied (broken wire between E1037 and Y66).
Control the adjustment value of the pressure control valve. Is the value set at 110 bar?
N
-
Adjust the pressure control valve (see adjustment of the pressure control valve).
LFR/en/version: 08 / 2007
The button S157 or the wire between S157 and E1037 is broken.
MJFCIFSS
11 - 27
Service Manual
Troubleshooting
When you press the button S158 that controls the ladder descending motion, the ladder doesnt go
down.
Is the indicator H68 (ladder unlocked) on?
N
-
N
-
Verify if the led corresponding to the solenoid valve Y67 on the connection box E1037 is on when
you push the button S158.
N
-
The solenoid valve Y67 is defective or is not supplied (broken wire between E1037 and Y67).
Control the adjustment value of the pressure control valve. Is the value set at 110 bar?
N
-
Adjust the pressure control valve (see adjustment of the pressure control valve).
One or several components of the rotating cylinder RCL are defective. You can nevertheless make
the ladder go down by switching the valve on the rotating cylinder.
LFR/en/version: 08 / 2007
11 - 28
MJFCIFSS
Service Manual
11.4.2Service trap
Problem : the service trap can not be unlocked
-
When you press the button S161 that controls the service trap unlocking, the trap gets not unlocked.
Does the motor M10 work?
N
-
Verify if the led corresponding to the solenoid valve Y70 on the connection box E1037 is on when
you push the button S161.
N
-
The solenoid valve Y70 is defective or is not supplied (broken wire between E1037 and Y70).
Control the adjustment value of the pressure control valve. Is the value set at 110 bar?
N
-
Adjust the pressure control valve (see adjustment of the pressure control valve).
The lock service trap cylinder CLS is defective or is blocked by an intruding object.
LFR/en/version: 08 / 2007
The button S161 or the wire between S161 and E1037 is broken.
MJFCIFSS
11 - 29
Service Manual
Troubleshooting
When you press the button S162 that controls the service trap descending motion, the trap doesnt
go down.
Is the indicator H70 (service trap unlocked) on?
N
-
N
-
Verify if the led corresponding to the solenoid valve Y71 on the connection box E1037 is on when
you push the button S162.
N
-
The solenoid valve Y71 is defective or is not supplied (broken wire between E1037 and Y71).
Control the adjustment value of the pressure control valve. Is the value set at 110 bar?
N
-
Adjust the pressure control valve (see adjustment of the pressure control valve).
LFR/en/version: 08 / 2007
11 - 30
MJFCIFSS
Service Manual
When you press the button S159 that controls the service trap descending motion, the trap doesnt
go down.
Does the motor M10 work?
N
-
Verify if the led corresponding to the solenoid valve Y68 on the connection box E1037 is on when
you push the button S159.
N
-
The solenoid valve Y68 is defective or is not supplied (broken wire between E1037 and Y68).
Control the adjustment value of the pressure control valve. Is the value set at 110 bar?
N
-
Adjust the pressure control valve (see adjustment of the pressure control valve).
LFR/en/version: 08 / 2007
The button S159 or the wire between S159 and E1037 is broken.
MJFCIFSS
11 - 31
Service Manual
Troubleshooting
When you press the button S160 that controls the service trap locking, the trap gets not locked.
Is the indicator H69 (service trap not in top position) on?
N
-
Push the button S160 until the service trap is in top position.
The service trap can now be locked.
N
-
Verify if the led corresponding to the solenoid valve Y69 on the connection box E1037 is on when
you push the button S160.
N
-
The solenoid valve Y69 is defective or is not supplied (broken wire between E1037 and Y69).
Control the adjustment value of the pressure control valve. Is the value set at 110 bar?
N
-
Adjust the pressure control valve (see adjustment of the pressure control valve).
The lock service trap cylinder CLS is defective or is blocked by an intruding object.
LFR/en/version: 08 / 2007
11 - 32
MJFCIFSS
Service Manual
11.5Adjustment instructions
11.5.1Adjustment of the pressure control valve
LFR/en/version: 08 / 2007
MJFCIFSS
11 - 33
Service Manual
11.6.1.1Description
The electro gear pump consists in two main parts :
The direct current motor.
The geared pump.
O-ring
Direct current motor
Plain washer
Hex. screw
Driver
7
10
30
31
32
LFR/en/version: 08 / 2007
2
3
4
5
6
11 - 34
MJFCIFSS
Service Manual
11.6.1.2Function
LFR/en/version: 08 / 2007
MJFCIFSS
11 - 35
Service Manual
Oil seal
Spring clip
Seal kit
Spring ring
Hex. HD screw
Protecting cap
Locking plug
LFR/en/version: 08 / 2007
3
5
10
15
16
24
25
11 - 36
MJFCIFSS
Service Manual
11.6.2Rotating cylinder
11.6.2.1Functional description
The oil pressure that is supplied through connections P1 and P2 causes a rotary movement on the actuator
shaft. The linear movement of the piston K is converted into a rotary movement by means of multiple helical
gears in the housing, piston and shaft.
LFR/en/version: 08 / 2007
11.6.2.3Cushioning adjustment
After loosening the self-sealing lock nut, the throttle section can be adjusted by an Allen key.
Turn the tapered throttle valve screw right in and loosen it one turn. The fine adjustment of the cushioning can
now be made.
MJFCIFSS
11 - 37
Service Manual
1
2
3
Piston rod
Cylinder
Guide but
4
5
6
Piston
Seal kit
Hex. nut
LFR/en/version: 08 / 2007
When there is an oil leak in a hydraulic cylinder, check the seal kit.
11 - 38
MJFCIFSS
Service Manual
11.6.4.2Function
During operation, the system pressure pushes against the front side of piston 31.
The same pressure is simultaneously applied via orifice A on the backside of piston 31, and via orifice B to
poppet 33. Springs 32 and 14 move piston 31 and poppet 33 into closed position.
LFR/en/version: 08 / 2007
As soon as the system pressure exceeds the pressure setting of spring 14, the poppet 33 is lifted off its seat,
and some fluid escapes into the return line via orifice D. The previous static condition is now dynamic as fluid
is trying to flow via orifice A in order to compensate the loss of volume and pressure. The size of the orifice
prevents immediate compensation, and a temporary difference in pressure between the upper and the bottom
of the main piston 31 exists.
The difference in pressure causes the system pressure, which is still pushing against the front of the piston 31,
to lift the piston from its seat and large amounts of fluid can return to the tank via connection C.
11.6.4.3Pressure adjustment
To adjust pressure, remove cap 23, loosen lock nut 35 and turn the adjustment screw 34 clock - or counterclockwise to lower or raise the pressure. After the adjustment has been made, secure screw with lock nut (torque to 10 Nm) and install a lead seal.
MJFCIFSS
11 - 39
Service Manual
11.6.5Solenoid-valve
Note : before removing the solenoid-valve observe all safety requirements :
Turn the motor M10 off.
Relieve the hydraulic lines by moving the servo control valve several times.
Verify that no one can manipulate the ladder during the removal of the solenoid-valve.
11.6.5.1Description
LFR/en/version: 08 / 2007
The piston slide valve can move in different positions with the magnet A or B. The pressure arrives from P, and
will go out from the hole A or B (it depends in which position is the piston slide valve), and will feed in oil the
cylinders. The other hole (A or B), evacuate the pressure oil which is coming back from the cylinders to the oil
tank T. The neutral position of the piston slide valve is set with return springs.
11 - 40
MJFCIFSS