FAIZOL82

Vertical and Horizontal Hydrotest Position

Commentator

11/23/2008 11:41 PM

Join Date: Oct 2008


Posts: 56

Dear Members,
What is diffrent between Vertical & Horizontal Hydrotest Position. I always used Horizontal hydrotest position for any type of vessel. Could
anyone interpret to me litte bit regarding this matter.

Interested in this topic? By joining CR4 you can "subscribe" to


this discussion and receive notification when new comments are added.
Join CR4, The Engineer's Place for News and Discussion!

Garyvan
Associate

#1

Re: Vertical and Horizontal Hydrotest Position


11/25/2008 1:46 AM

Hi Faizol,

Join Date: Jun 2008


Posts: 26
Good Answers: 5

HarryBurt
Power-User

I assume that you are talking about vessels that are fairly tall. If so, then the only difference when hydrotesting the vessel in the vertical
position is that you must take the static head of the water into account. The top of the vessel must obviously experince the full hydrotest
pressure, so the bottom of the vessel will experince this pressure plus the static head. The pressure guage is usually at the bottom of the
vessel, so when testing ensure that the guage reads the total pressure (test pressure plus static head).

#2

Re: Vertical and Horizontal Hydrotest Position


11/25/2008 11:03 AM

I would think that the better position would be the one the vessel will be used in. As stated above, a tall vertical vessel will have a higher
pressure at the bottom that at the top, while a horizontal vessel will have the same pressure throughout.
__________________
"Just a little off the top" - Marie Antoinette

Join Date: Jul 2007


Location: Cleveland, OH
Posts: 447
Good Answers: 10

FAIZOL82

#3

Re: Vertical and Horizontal Hydrotest Position

Commentator

11/25/2008 7:38 PM

Join Date: Oct 2008


Posts: 56

Dear Members,
anybody know how to calculate stress for every parts like bottom head, shell and top head using manual calculation. Could someone guide
me and provide a stress formula.
Thank you.

Anonymous
Poster

#4

Re: Vertical and Horizontal Hydrotest Position


10/27/2009 5:18 PM

For vertical vessels tested horizontally, we have always added the static head to the required hydro pressure. Per interpretation
VIII-1-95-27, this is not required. The test pressure regardless of position is 1.3P times the materials stress ratio. Interpretation:
VIII-1-95-27 Subject: Section VIII, Division 1 (1992 Edition, 1993 Addenda); UG-99(b) Date Issued: January 12, 1995 File Number:
BC94-414 Related Documents: Question (1): Does the last sentence of UG-99(b) of Section VIII, Division 1, "All loadings that may exist
during this test shall be given consideration," require that the static head that exists in a tower in the vertical position must be considered
when determining the test pressure in the horizontal position? Reply (1): No. Question (2): Does UG-99 specify in which position a vertical
tower must be hydrotested? Reply (2): No.

Anonymous
Poster

#5

Re: Vertical and Horizontal Hydrotest Position


07/28/2010 4:31 AM

Register to Reply

5 comments

Back to top
Interested in this topic? By joining CR4 you can "subscribe" to
this discussion and receive notification when new comments are added.
Join CR4, The Engineer's Place for News and Discussion!

Users who posted comments:

Engineering Newsletter Signup

Copy to Clipboard

02/02/2016 5:57 PM

CR4 - Thread: Vertical and Horizontal Hydrotest Position

2 of 2

http://cr4.globalspec.com/thread/29695/Vertical-and-Horizontal-Hydro...

Anonymous Poster (2); FAIZOL82 (1); Garyvan (1); HarryBurt (1)

Previous in Forum: Video Direction Next in Forum: Ratings for Socket Welded Fittings
You might be interested in: Vertical Conveyors, Linear Position Sensors, Rotary Position Sensors

Advertisement

"It doesn't matter who you are, where you come from. The ability to triumph begins with you. Always." -- Oprah Winfrey
All times are displayed in US/Eastern (EST) (Register to change time zone)
2016 IHS. All rights reserved. Reproduction in whole or in part without permission is prohibited. The information contained on this site is by users for users and is provided for information
purposes only and does not constitute advice. Any views or opinions expressed by users are personal to them and do not represent the views or opinions of IHS. You should check any information
and use your own judgment or seek expert advice before doing or not doing anything on the basis of what you read here. IHS does not verify or warrant the accuracy or completeness of any
information on this site and, to the extent permitted by law, IHS shall not be liable for any loss, damage or expense incurred by reliance on it or for any dealings you have with users or other third
parties that take place using or facilitated by this site.