Professional Documents
Culture Documents
Features
If you need any transformer
bushing proven in operation
conditions around the world,
Trench has it !
experience in manufacturing
of bushings for more than
100 years
inclination in service up to
30 from vertical.
For COT(C) 125 and
COT(C) 170 even
horizontal operation is
possible
computer optimized
electrical field distribution
proven high electrical
withstand against transient
or impulse stresses
excellent long term stability
due to extremely low partial
discharge and power loss
factor
electrode embedded in
the lower epoxy resin part
- avoids external shielding
- reduces distance to ground
- lower transformer costs
To preserve our
environment the free oil
volume in COT-bushings
is minimized
Page 2 / 24
40497230_00
Cut view
General design
Design
10
2
1
Top terminal
Assembly
Head
Oil filling
Insulator
Active part
Flange
CT-Pocket
End-shielding
Page 3 / 24
9
10
40497230_00
Page 4 / 24
measurement
40497230_00
Insulation
See page 16
Cable
Page 5 / 24
40497230_00
08
09
10
Connection to Transformer
kV
kV
kV
kV
kV
kV
36
14
21
55
77
50
125
70
170
800
cable )
1250
rem.Co-cond. )
35
1600
fixed Co-cond.
2500
fixed Co-cond.
3150
fixed Co-cond.
800
52
30
105
95
250
COT 450
72,5
100
42
58
155
205
140
325
185
450
kg
235
600
22
2000
22
2000
28
2000
29
2000
32
2000
36
3150
*1116
31
2000
400
*1116
31
2000
400
1
cable )
2
340
rem.Co-cond. )
35
*1116
38
2000
1600
fixed Co-cond.
*1116
44
2000
2500
fixed Co-cond.
*1116
49
2000
3150
fixed Co-cond.
*1116
53
3150
1300
26
2000
26
2000
35
2000
36
2000
54
3150
75
4000
31
2000
31
2000
800
cable
400
1
cable )
400
2
1250
rem.Co-cond. )
35
1600
fixed Co-cond.
2500
fixed Co-cond.
3150
fixed Co-cond.
800
cable
400
1
1000
cable )
1250
rem.Co-cond. )
35
1600
fixed Co-cond.
2500
fixed Co-cond.
3150
fixed Co-cond.
800
465
600
1820
400
2
cable
400
820
2540
400
40
2000
44
2000
62
3150
88
4000
40
2000
40
2000
52
2000
1000
cable )
1250
rem.Co-cond. )
35
1600
fixed Co-cond.
56
2000
2500
fixed Co-cond.
80
3150
3150
fixed Co-cond.
106
4000
mm
1250
1000
COT 325
cable
15
mm
400
2
14
mm
400
1
1000
1000
COT 250
cable
13
/ kV
COT 170
24
12
25 mm
25mm/kV
COT 125
mm
mm
11
07
Mass Approx.
06
05
25mm/kV
04
03
02
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
01
Type
Page 6 / 24
40497230_00
08
16
17
18
19
20
21
22
24
25
26
27
28
29
30
31
32
33
L1
L2
L3
L6
L7
D2
D3
D4
D5
D6
D7
min
see
fig.
A
800
1000
1250
1600
2500
3150
800
1000
1250
1600
2500
3150
800
1000
1250
1600
2500
3150
800
1000
1250
1600
2500
3150
800
1000
1250
1600
2500
3150
12, 13:
15:
mm
761
761
140
140
621
621
452
452
761
140
621
729
140
589
729
140
729
140
895
895
mm
80
80
60
60
80
80
184
184
240
240
210
210
190
190
30
30
40
40
24
24
4
4
12
12
19
19
80
60
80
184
240
210
190
30
24
12
20
125
60
80
184
240
210
190
40
24
12
21
589
125
60
80
184
240
210
190
40
24
12
21
589
125
60
80
184
240
210
190
40
24
12
21
169
169
726
726
557
557
80
80
60
60
80
80
184
184
240
240
230
230
190
190
30
30
40
40
24
24
4
4
12
12
19
19
895
169
726
80
60
80
184
240
230
190
30
24
12
20
863
169
694
125
60
80
184
240
230
190
40
24
12
21
863
169
694
125
60
80
184
240
230
190
40
24
12
21
863
169
694
125
60
80
184
240
230
190
40
24
12
21
1090
1090
140
140
950
950
760
760
80
80
100
100
100
100
185
185
225
225
200
200
170
170
30
30
35
35
16
16
6
6
14
14
22
22
1090
140
950
80
100
100
185
225
200
170
30
16
14
23
1135
140
995
125
100
100
185
225
200
170
40
16
14
24
1095
140
955
125
110
120
200
240
231
170
60
22
15
25
1105
140
965
125
110
130
290
335
242
170
60
16
12
16
26
1210
175
1035
845
80
100
100
185
225
210
170
30
35
16
14
22
1210
1210
175
175
1035
1035
845
-
80
80
100
100
100
100
185
185
225
225
210
210
170
170
30
30
35
-
16
16
6
6
14
14
22
23
1255
175
1080
125
100
100
185
225
210
170
40
16
14
24
1275
175
1100
125
110
120
200
240
231
170
60
22
15
25
1285
175
1110
125
110
130
290
335
242
170
60
16
12
16
26
1503
1503
230
230
1273
1273
1085
1085
80
80
100
100
100
100
185
185
225
225
210
210
170
170
30
30
35
35
16
16
6
6
14
14
22
22
1503
230
1273
80
100
100
185
225
210
170
30
16
14
23
1548
230
1318
125
100
100
185
225
210
170
40
16
14
24
1543
230
1313
125
110
120
200
240
231
170
60
22
15
25
1553
230
1323
125
110
130
290
335
242
170
60
16
12
16
26
16, 17:
24, 25, 29, 32:
Page 7 / 24
40497230_00
255
230
550
kV
10
Connection to Transformer
800
cable
11
13
14
15
mm
mm
mm
kg
1050
3100
62
3150
400
1
12
kV
09
Mass Approx.
71
kV
08
123
kV
07
COT 550
06
05
04
03
02
01
01
Type
02
1000
cable )
400
62
3150
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
1250
rem.Co-cond.2)
35
74
3150
1600
fixed Co-cond.
2500
fixed Co-cond.
3150
fixed Co-cond.
COT 750
170
84
98
305
355
275
325
650
750
800
COT 1050
245
300
142
173
505
560
460
510
1050
1050
400
1000
cable )
400
1250
rem.Co-cond.2)
35
1600
fixed Co-cond.
2500
fixed Co-cond.
3150
fixed Co-cond.
800
1000
COT 1050
cable
cable
400
1
cable )
500
2
1250
rem.Co-cond. )
35
1600
fixed Co-cond.
2500
fixed Co-cond.
3150
fixed Co-cond.
750
800
cable
400
1
1250
1460
4000
173
4000
81
3150
81
3150
3625
98
3150
101
3150
190
4000
198
4000
92
4000
92
4000
111
4000
117
4000
315
5000
223
5000
236
4000
4250
*5270
2150
3150
25mm / kV
145
COT 650
79
165
6125
750
1000
cable )
500
236
4000
750
1250
rem.Co-cond.2)
38
266
4000
750
1600
fixed Co-cond.
285
4000
750
2500
fixed Co-cond.
328
5000
750
3150
fixed Co-cond.
332
5000
850
1000
Cable
350
5000
850
1600
fixed Co-cond.
440
5000
850
2500
fixed Co-cond.
445
5000
630
2400
7500
Page 8 / 24
40497230_00
08
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
L1
L2
L3
L6
L7
D1
D2
D3
D4
D5
D6
D7
min
see
fig.
mm
800
1000
1250
1600
2500
3150
1805
1805
310
310
1495
1495
1306
1306
1805
310
1495
1850
310
1540
2089
310
2052
310
800
1000
1250
1600
2500
3150
2055
2055
800
1000
1250
1600
2500
3150
mm
80
80
110
110
120
120
250
250
290
290
231
231
170
170
30
30
35
35
16
16
8
8
15
15
27
27
80
110
120
250
290
231
170
30
16
15
28
125
110
120
250
290
231
170
40
16
15
29
1779
125
195
175
290
290
295
300
60
20
12
20
30
1742
125
195
175
400
450
295
300
60
22
12
22
31
360
360
1695
1695
1506
1506
80
80
110
110
130
130
290
290
335
335
242
242
170
170
30
30
35
35
16
16
12
12
16
16
27
27
2055
360
1695
80
110
130
290
335
242
170
30
16
12
16
28
2100
360
1740
125
110
130
290
335
242
170
40
16
12
16
29
2339
360
1979
125
195
175
290
335
295
300
60
20
12
20
30
2302
360
1942
125
195
175
400
450
295
300
60
22
12
22
31
2325
2325
420
420
1905
1905
1716
1716
80
80
110
110
130
130
290
290
335
335
242
242
170
170
30
30
35
35
16
16
12
12
16
16
27
27
2325
420
1905
80
110
130
290
335
242
170
30
16
12
16
28
2370
420
1950
125
110
130
290
335
242
170
40
16
12
16
29
2609
420
2189
125
195
175
290
335
335
300
60
20
12
20
30
2572
420
2152
125
195
175
400
450
295
300
60
22
12
22
31
800
1000
1250
1600
2500
3150
3518
684
2834
2500
80
195
175
400
450
295
300
30
40
22
12
22
32
3518
3518
684
684
2834
2834
2500
-
80
80
195
195
175
175
400
400
450
450
295
295
300
300
30
30
40
-
22
22
12
12
22
22
32
33
3563
684
2879
125
195
175
400
450
295
300
40
22
12
22
34
3563
684
2879
125
195
200
400
450
340
300
60
22
12
22
35
3407
684
2842
125
195
200
400
450
340
300
60
22
12
22
36
1000
1600
2500
3813
3813
684
684
3129
3129
2750
-
80
125
195
195
200
200
400
400
450
450
350
350
300
300
40
40
55
-
22
22
12
12
22
22
37
38
3742
650
3092
125
195
200
400
450
350
300
50
22
12
22
39
12, 13:
15:
16, 17:
24, 25, 29, 32:
Page 9 / 24
40497230_00
09
10
kV
kV
362
209
560
510
1175
950
1000
cable
02
1600
03
15
mm
kg
630
2800
9115
480
5000
Fixed cond.
2800
2500
Fixed cond.
2800
1000
cable
630
2800
05
1600
Fixed cond.
2800
06
2500
Fixed cond.
2800
1000
cable
630
3300
08
1600
Fixed cond.
09
2500
Fixed cond.
1000
cable
11
1600
Fixed cond.
12
2500
Fixed cond.
1000
cable
14
1600
15
04
07
10
13
COT 1175
COT 1300
COT 1425
COT 1550
420
550
243
318
695
750
630
680
1425
1550
1050
1175
5000
530
5000
560
5000
*13750
865
5000
3300
*13750
930
5000
3300
*13750
990
5000
3800
14350
940
5000
1000
5000
1030
5000
980
5000
1060
5000
1100
5000
1050
5000
1150
5000
1200
5000
3800
3800
Fixed cond.
3800
1000
cable
630
4200
17
1600
Fixed cond.
4200
18
2500
Fixed cond.
4200
1800
1175
630
500
2500
790
1675
950
3800
870
680
1300
318
750
570
Fixed cond.
550
318
625
3800
COT 1800
550
209
5000
630
16
COT 1675
362
5000
540
9115
25 mm / kV
01
25m m/kV
mm
mm
mm
mm
kV
14
Mass Approx.
kV
13
kV
12
kV
11
08
07
06
Connection to Transformer
05
Transformer Power frequency voltage
withstand (AC)
04
Bushing Dry Power frequency voltage
withstand (AC)
03
02
01
Type
14350
14350
Page 10 / 24
40497230_00
08
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
L1
L2
L3
L6
L7
D1
D2
D3
D4
D5
D6
D7
see
fig.
mm
mm
1000
4270
720
3550
3240
125
250
235
400
450
390
330
40
55
22
12
22
40
1600
4230
720
3510
125
250
235
400
450
390
330
40
22
12
22
41
2500
4230
720
3510
125
250
235
400
450
390
330
40
22
12
22
41
1000
4270
720
3550
3240
125
250
235
400
450
390
330
40
55
22
12
22
40
1600
4230
720
3510
125
250
235
400
450
390
330
40
22
12
22
41
2500
4230
720
3510
125
250
235
400
450
390
330
40
22
12
22
41
1000
5055
820
4235
3995
125
280
291
380
530
590
477
400
40
68
23
12
25
42
1600
4965
820
4145
125
280
291
380
530
590
477
400
40
23
12
25
43
2500
4965
820
4145
125
280
291
380
530
590
477
400
50
23
12
25
43
1000
5790
1055
4735
4495
125
280
291
380
530
590
455
500
40
68
23
12
25
42
1600
5700
1055
4645
125
280
291
380
530
590
455
500
40
23
12
25
43
2500
5700
1055
4645
125
280
291
380
530
590
455
500
50
23
12
25
43
1000
5935
1200
4735
4495
125
280
291
380
530
590
455
500
40
68
23
12
25
42
1600
5845
1200
4645
125
280
291
380
530
590
455
500
40
23
12
25
43
2500
5845
1200
4645
125
280
291
380
530
590
455
500
50
23
12
25
43
1000
6345
1200
5145
4895
125
280
291
380
530
590
455
500
40
68
23
12
25
42
1600
6245
1200
5045
125
280
291
380
530
590
455
500
40
23
12
25
43
2500
6255
1200
5055
125
280
291
380
530
590
455
500
50
23
12
25
43
12, 13:
15:
16, 17:
24, 25, 29, 32:
Page 11 / 24
40497230_00
Dimensional Drawing
D6
View A
L6
D5
L3
L2
AD
Fig. 1
Fig. 2
D4
e L7
L4
D1
Only for COT
420 kV
L1
30
L1
D7
Fig. 3
D
Fig. 4
Page 12 / 24
Fig. 5
40497230_00
Gray color
(ANSI gray N70)
D4
Alternate sheds
(ANSI gray N70)
D4
Helicoil sheds
(ANSI gray N70)
D4
D4
All COT(C) can be equipped with silicone rubber insulators upon request without affecting dimensions
except D4
Page 13 / 24
40497230_00
Standard
Oil level indicator
COT 125, COT 170
20
60
Fig. 6
Fig. 7
O-ring gasket
22
6
Flat gasket
Fig. 8
Fig. 9
Page 14 / 24
40497230_00
Options
Magnetic oil level indicator (95)
COT 250 COT 1800
Arcing horns
Type
S
min
max
mm
COT 125
COT 170
COT 250
220
270
COT 325
300
390
COT 450
430
520
COT 550
420
650
COT 650
500
750
COT 750
500
850
COT 1050
750
1200
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Page 15 / 24
40497230_00
External shield
These
bushings
are
equipped on the lower
end with a cone shaped
epoxy resin tube and an
embedded
electrode.
Therefore,
additional
barriers or electrodes
may be omitted and
distance to ground is
reduced
R1
Oil conditions:
Mineral oil with less than 10ppm water content and
dielectric strength higher than 60kV (acc. to IEC 60156)
Fig. 14
Fig. 15
COT 1050
40
35,7
Type
Min.
insulation
thickness
S
Min. distance to
grounded parts
R
R1
mm
28
50
S
15
30
S
80 (Um=245kV)
94 (Um=300kV)
Fig. 16
COT 125
65
COT 170
75
COT 250
10
85
COT 325
10
120
COT 450
12
135
COT 550
12
145
250
COT 650
15
180
275
COT 750
15
225
300
COT 1050
20
300
375
COT 1175
to
COT 1800
See spec
40497124
Fig. 17
Page 16 / 24
40497230_00
Removable
split conductor
30
3 fixing screws
30
29
Fig. 18
1250A
1000A
40
40
30
29
125
Conductor 35
80
80
Cable
40
Fig. 19
Page 17 / 24
80
Fig. 20
Fixed copper-conductor
Fig. 21
40497230_00
1250A
1000A
30
29
90
Conductor 35
35,7
35
80
Cable
80
Removable copper conductor
Fig. 22
80
Fig. 23
Fixed copper-conductor
3150A
2500A
125
125
40
40
94
104
Fixed copper-conductor
Fig. 24
Fixed copper-conductor
Fig. 25
Page 18 / 24
Fig. 26
40497230_00
1250A
1000A
30
41
28
29
15
90
Conductor 35
35,7
35
68
Cable
68
68
Fig. 27
Fig. 28
Fixed copper-conductor
Fig. 29
3150A
2500A
15
22,5
125
125
150
195
40
86
40
114
160
240
Fixed copper-conductor
Fig. 30
Page 19 / 24
40497230_00
1250A
1000A
30
30
14
78
50
29
40
90
25
Conductor 38
80
119
119
119
Cable
35
Fig. 32
Fixed copper-conductor
Fig. 33
Fig. 34
3150A
2500A
230
125
125
170
40
40
95
180
260
134
Fixed copper-conductor
Fig. 35
Page 20 / 24
40497230_00
1600A
30
14
50
55
90
25
35
95
95
134
134
Cable
Fixed copper-conductor
Fig. 37
Fig. 38
2500A
230
125
170
40
180
260
Fixed copper-conductor with removable screwed shield
Page 21 / 24
Fig. 39
40497230_00
1600A
120
80
55
110
125
190
Cable with fixed shield
Fig. 40
Fig. 41
1600A
68
280
210
160
210
160
330
Cable with fixed shield
Fig. 42
Page 22 / 24
Fig. 43
40497230_00
FIXED SHIELD
SCREWED SHIELD
Detail A
Connection according to
customer drawing
Fig. 45
Fig. 46
Page 23 / 24
40497230_00
Product Range
Quality
Bushings for
Power Transformers
up to 550 kV, 5000A
High Current Application
up to 52 kV, 40000 A
Transformer to SF6
connection up to 550kV
Gas-insulated Switchgear
(GIS) up to 800 kV, 6000A
Generators
up to 36 kV, 50000 A
Railways
Buildings , Wall
up to 245 kV, 5000 A
Bushings according
Standard IEC 60137
Bushings according to
customers special specification
Trench China
MWB (Shanghai) Co., Ltd
No. 3658, Jiancheng Road
Minhang, Shanghai
Peoples Republic of China
200245
Phone: +86-21-54720088
Fax: +86-21-54723118
Trench Limited
Bushing Division
40497230_00
www.trenchgroup.com
Sales-bushing.fr@trench-group.com