You are on page 1of 19

Page : 1

SERVICE MANUAL
1

Refrigerator

FOR EXPORT 2010

Specifications

1-1) Specific parts for specific countries


Item
No.
1.

Model
HR-953F

PRINTED : Jun2010

Destination
VENEZUELA (VE)

Power Source
(Voltage-ac / Hz)
115 / 60

Power Cord

Internal Volume (Litre)


(by ISO 8561;1995)

J2 (USA Style)

522

REF NO. SM7710154-00_11

Page : 2

1-2) Product
Model

HR-953F

Classification
Temperature Control
Defrost System
Drain
Evaporator
Condenser
Cabinet
Insulation
Freezer Door
Refrigerator Door
Refrigerant
Refrigerant Charge (g.)
Overall Dimension (WxDxH (mm.))
Packing Dimension (WxDxH (mm.))
Net Weight (kg.)
Gross Weight (kg.)

2 Doors No Frost
Thermostat
Automatic
Automatic (Heat by transfer from the Condenser)
Aluminum Coil With Bond
Pipe Condenser
Rigid Polyurethane Foam ( Cyclopentane )
Rigid Polyurethane Foam ( Cyclopentane )
Rigid Polyurethane Foam ( Cyclopentane )
HFC-134a
150
798 x 708 x 1780
852 x 775 x 1961
91.0
100.0

1-3) Characteristic of Thermostat


Operating Temperature (C) 1013hPa (mb)
Temperature
Control

Model
Dial Position
WARM

MM1-8053
C

NORMAL

COLD

ON
-18.4

OFF
- 21.7

-21 1.5
- 26.7

-24.5 1.5
-30.9

1-4) Electrical Parts


1-4-1) MODEL HR-953F
Model
Compressor

Power Supply Range

Starting Relay
Overload Protector
Starting Capacitor
Running Capacitor
Interior Light

PRINTED : Jun2010

C-BZN 176L2Z
115-127 V / 50-60 Hz
MTRP4615
4TM 427PHBYY-53
60 F / 160 VAC
240 V / 10 W

REF NO. SM7710154-00_11

Page : 3

Wiring Diagram

FIXED CAPACITOR(S)

R LAMP

PRINTED : Jun2010

REF NO. SM7710154-00_11

Page : 4

1
2
3
4
5
6
7
8

Refrigerant Circuit

COMPRESSOR
TUBE CHARGE
TUBE CONNECT 139
ACCUMULATOR / MUFFER
TUBE CONNECT 145
TUBE CONNECT 143
CONDENSER PIPE
CONDENSER PLATE

PRINTED : Jun2010

9
10
11
12
13
14
15

DRYER ASSY
TUBE DISCHARGE
TUBE FRAME
TUBE CREST
TUBE CREST S
EVAPORATOR ASSY
SUCTION TUBE ASSY

REF NO. SM7710154-00_11

Page : 5

Trouble Shooting

4-1) MODEL HR-953F (VENEZUELA)


Part Name
Compressor

Starting Relay

Overload Protector

Picture

Check Method and Criterion


Measure the resistance with a tester.
(Ambient temperature : Room temperature 25C)
Model
Main Wiring
Auxiliary Wiring
- (Approx.)
- (Approx.)
Normal
C-BZN176 L2Z Abnormal Open( ) or Short Circuited (0 )
Measure the resistance with a tester.
(Ambient temperature : Room temperature 25C)
Model
MTRP4615
Pick up current
3.50
max.(A)
Drop out
3.05
current min.(A)
Measure the resistance with a tester.
(Ambient temperature : Room temperature 25C)
Model
4TM427PHBYY-53
Normal
Abnormal

Stating Capacitor

Open() or Short Circuited (0)

Measure the resistance with a tester.


(Ambient temperature : Room temperature 25C)
Model
60 F / 160 VAC
Normal
Abnormal

PRINTED : Jun2010

Less than 1 (Approx.)

Open()
Short Circuited (0)

REF NO. SM7710154-00_11

Page : 6

Replacement of Parts

Unplug the power cord before servicing.


1. Model : HR-953F
Part Name
Thermostat

Operating Procedure

1. Release Freezer Corner lock.

2. Remove Freezer Corner.

3.Turn Knob Thermo F to Min position.

4. Dig Knob Thermo F out.

5. Pull out Knob Thermo F.

6. Dig Cover Cap out.

7. Release screw form FF.Cover.

8. Lift FF.Cover out.

9. Pull out Thermostat from Plate MTG.


Motor.

PRINTED : Jun2010

REF NO. SM7710154-00_11

Page : 7
12. Pull out Thermostat from Plate MTG.
Motor.

10. Pull out Socket of Thermostat.

11. Press Thermostat to remove lock.

13. Pull out Terminal.

14. After replacing Thermostat, reverse the steps above.

Part Name

Operating Procedure

Fan Blade.

- Follow step 1-8 of replacing Thermostat.

1. Use Pliers to catch at Fan Ring.

2. Pull out Fan Blade F from Plate MTG


Motor.

3. Pull out Fan Ring from Fan Blade F.

4. After replacing Fan Blade F, reverse the steps above.

PRINTED : Jun2010

REF NO. SM7710154-00_11

Page : 9
Part Name

Fan Motor

Operating Procedure
- Follow step 1-8 replacing Thermostat.
- Follow step 1-2 replacing Fan Blade.

1. Release screw form Plate MTG. Motor. 2. Lift Plate MTG. Motor out.

3. Release screw form Cover Fan Motor.

4. Pull out Cover Fan Motor form Plate


MTG. Motor.

6. After replacing Fan Motor, reverse the


steps above.

PRINTED : Jun2010

5. Lift Fan Motor out.

REF NO. SM7710154-00_11

Page : 10
Part Name

Heater

Operating Procedure
- Follow step 1-8 replacing Thermostat.
- Follow step 1-2 replacing Fan Blade.
- Follow step 1-2 replacing Fan Motor.

1. Pull out Socket of Heater.

2. Pull out Socket of Heater.

3. Hold firmly and life Evaporator Assy up.

4. Remove Aluminium tape that cover


electrical wire.

5. Lift up Heater set form its lock.

6. After replacing Heater, reverse the


steps above.

PRINTED : Jun2010

REF NO. SM7710154-00_11

Page : 11
Part Name

Thermal Fuse Assy

Operating Procedure

1. Pull out Socket of Thermal Fuse

Assy.

2. Cut out Cable Tie from Evaporator


tube.

4. Remove Thermal Fuse Assy.

5. After replacing Thermal Fuse Assy, reverse the steps above.

PRINTED : Jun2010

Follow step 1-8 replacing Thermostat.


Follow step 1-2 replacing Fan Blade.
Follow step 1-2 replacing Fan Motor.
Follow step 1-3 replacing Heater.

3. Cut out Cable Tie from Evaporator


tube.

REF NO. SM7710154-00_11

Page : 12
Part Name
Bimetal Thermo

1. Pull out Socket of D Sensor Assy.

Operating Procedure
-

Follow step 1-8 replacing Thermostat.


Follow step 1-2 replacing Fan Blade.
Follow step 1-2 replacing Fan Motor.
Follow step 3 replacing Heater.

2. Cut out Cable Tie from Evaporator


tube.

3. Remove Aluminium tape that cover D


Sensor Assy.

4. After replacing D Sensor Assy, reverse the steps above


Part Name
Door Switch.

Operating Procedure

1. Dig Door Switch out.

2. Pull Door Switch form Inner Box.

* Use a small flatten screwdriver to prize Door Switch.

3. Hold recept Socket.

4. After replacing Door Switch, reverse the steps above.

PRINTED : Jun2010

REF NO. SM7710154-00_11

Page : 13
Part Name
Lamp.

Operating Procedure

1. Pull out Coated Shelf.

2. Unlock Shield Light R out.

3. Remove Shield Light R from Duct.

4. Turn Lamp counterclockwise to


remove.

5. Remove Lamp from Lamp socket.

6. After Replacing Lamp, Reverse steps


above.

PRINTED : Jun2010

REF NO. SM7710154-00_11

Page : 14
Part Name
Damper Thermostat

Operating Procedure

1. Remove Tray Chiller.

2. Release Door.

3. Remove Coated Shelf.

4. Remove Crisper .

5. Remove Tray Chiller.

6. Dig Cover Cap out.

7. Release screw from Cover Thermo .

8. Dig Knob Thermo R.

9. Pull out Knob Thermo R from Cover


Thermo.

PRINTED : Jun2010

REF NO. SM7710154-00_11

10. Lift out Cover Thermo.

11. Lift out Insulation.

Page : 15
12. Remove paper tape from Insulation.

13. Remove Seal from Insulation.

14. Remove paper tape from Damper


Thermostat.

15. Straighten Damper Thermostat


sensing tube.

16. Separate Insulation from each other.

17. Pull Case Damper from Insulation.

18. Release screws that hold Damper

Thermostat and Case Damper.

19. Pull Damper Thermostat from Case 20. After Replacing Damper Thermostat, Reverse steps above.
Damper.

PRINTED : Jun2010

REF NO. SM7710154-00_11

Page : 16
Part Name
Lamp Socket.

Operating Procedure
- Follow stop 1-11 of replacing Damper Thermostat.

1. Release screws form Duct.

2. Lift out Duct and Insulation L-R.

3. Release screws form Plate MTG.

4. Pull out Socket.

5. Remove paper tape form Plate MTG.

6. Press R Lamp Socket to remove lock.

7. Lift out R Lamp Socket.

8. After replacing R Lamp Socket, reverse the steps above.

PRINTED : Jun2010

REF NO. SM7710154-00_11

Page : 17
Part Name
Timer.

Operating Procedure

1. Release screw form Case Elec Cover. 2. Lift out Case Elec Cover.

4. Pull out Terminal.

PRINTED : Jun2010

3. Release screw that hold Timer trom


the Case Elec Cover.

5. After replacing Fan Motor R, reverse the steps above.

REF NO. SM7710154-00_11

Page : 18
Part Name
Running Capacitor.

Operating Procedure
- Follow stop 1-2 of replacing Timer.

1. Pull out Starting Capacitor Form Case 2. Pull out Terminal form Starting
Elec.
Capacitor.

Part Name
Fan Motor Relay

Operating Procedure
- Follow stop 1-2 of replacing Timer.

1. Remove Fan Motor Relay.

2. Pull out Terminal form Fan Motor


Relay.

PRINTED : Jun2010

3. After Replacing Running Capacitor,


Reverse steps above.

3. After Replacing Fan Motor Relay,


Reverse steps above.

REF NO. SM7710154-00_11

Page : 19
Part Name
Starting Relay.

Operating Procedure

1. Release Relay Cover Fixing Clip.

2. Remove Relay Cover.

4. Hold Recept Terminal then pull


electical wires from Starting Relay.

5. After Replacing Starting Relay, Reverse steps above.

PRINTED : Jun2010

3. Remove Starting Relay.

REF NO. SM7710154-00_11

Page : 20
Part Name
Overload Protector

Operating Procedure
- Follow stop 1-3 of replacing Starting Relay.

1. Remove Overload Protector.

2. Hold Recept Terminal then pull


electical wires from Overload Protector.

PRINTED : Jun2010

3. After Replacing Overload Protector,


Reverse steps above.

REF NO. SM7710154-00_11