Professional Documents
Culture Documents
CS
Easy
Tough
Safe
Durability improved by
tough body
Relief Valve
prevents accidents.
[Water Treatment]
Algicides
Corrosion/rust
inhibitors
Slime inhibitors
Scale inhibitors
Sulfuric acid
Hydrochloric acid
Caustic soda
Polyaluminum chloride (PAC)
Polymer molecule flocculants
[Boiler]
Relief Valve
[Sterilization]
Rust inhibitors
Deoxidizers
pH conditioners
Corrosion/rust
inhibitors
Sodium hypochlorite
. . . etc
OPEN
For Injection of
Boiler Chemicals
Relief
Valve
For Injection of
High-viscosity Chemicals
Relief
Valve
For Injection of
Sodium Hypochlorite
Relief
Valve
(hose type)
VTCE/ VTCF
FTCE/FTCF/FTCT
STCT/6TCT
VTCE
VT6E
ATCF (CLCS )
Material: PVC
Application: Transfer/
injection of general
(flange type)
chemicals
Material: PVDF
Application: Transfer/injection of
special chemicals
(e.g. strong and mixed acids)
Material: PVC
Application: Transfer/injection of
boiler chemicals
Material: PVC
Application: Transfer/injection of
high-viscosity chemicals
(e.g. polymer coagulants)
Material: PMMA
Application: Transfer/injection of
chemicals that easily cause gas lock
(e.g. sodium hypochlorite)
Model Code
CS
10
1
1 Series name
When selecting the pump model, refer to the "Liquid-end Material & Corrosion-resistance Table".
VTCE
2 Model
(discharge volume standard)
3 Liquid-end
material
HW
4
4 Joint
specification
CS
w/ Relief Valve
10R :
30R :
60R :
100R :
300R :
10 mL
30 mL
60 mL
100 mL
300 mL
VTCE
VTCF
10N : 10 mL
30N : 30 mL
60N : 60 mL
100N : 100 mL
300N : 300 mL
600 : 600 mL
1000 :1000 mL
10R :
30R :
60R :
100R :
300R :
10 mL
30 mL
60 mL
100 mL
300 mL
FTCE
FTCF
FTCT
6TCT
STCT
VTCE
10
30
60
100
300
:
:
:
:
:
10 mL
30 mL
60 mL
100 mL
300 mL
w/ Relief Valve
10R :
30R :
60R :
100R :
300R :
10 mL
30 mL
60 mL
100 mL
300 mL
10
30
60
100
300
600
1000
: 10 mL
: 30 mL
: 60 mL
: 100 mL
: 300 mL
: 600 mL
:1000 mL
10
30
60
100
300
:
:
:
:
:
10 mL
30 mL
60 mL
100 mL
300 mL
600 : 600 mL
1000 :1000 mL
CS
w/ Relief Valve
10R :
30R :
60R :
100R :
10 mL
30 mL
60 mL
100 mL
10N :
30N :
60N :
100N :
10 mL
30 mL
60 mL
100 mL
CS
VT6E
30N : 30 mL
60N : 60 mL
100N : 100 mL
300N : 300 mL
600 : 600 mL
1000 :1000 mL
CLCS
w/ Relief Valve
10R :
30R :
60R :
100R :
10 mL
30 mL
60 mL
100 mL
10N :
30N :
60N :
100N :
10 mL
30 mL
60 mL
100 mL
ATCF
5 Motor specification
(voltage + phases)
6 Paint
color
[1-phase]
100V1 : 100 V/110 V
120V1 : 115 V/120 V
200V1 : 200 V/220 V
230V1 : 230 V/240 V
Y:
S : Standard
(w/out cable or
terminal block)
C : w/ cable
(2 m)
[3-phase]
200V3 : 200 V/220 V/230 V
400V3 : 346 V/380 V/400 V/
415 V/440 V
w/ Relief Valve
100V1
Yellow
T : w/ terminal block
S : Standard
Specification
For Injection of General Chemicals
Model
10R
VTCE/
VTCF
Item
Max. discharge
50 Hz
volume*1
60 Hz
(mL/min)
Max. discharge pressure*1 MPa
Stoke speed 50 Hz
(strokes/min) 60 Hz
Stroke length (mm)
60R
FTCE/
FTCF/
FTCT
VTCE/
VTCF
10
12
VTCE/
VTCF
30
36
100R
FTCE/
FTCF/
FTCT
60
72
0.7*2
0 to 2
4x9
6x8
4x9
6x8
5.0
5.2
5.0
6 x 11
6x8
100
120
300
360
104
125
102
122
0 to 6
6 x 11
4x6
100 mPa.s
0 to 40
/ FTCE/FTCF/FTCT: 0 to 60
IEC529-IPX3 (water-proof)
5.2
5.0
FTCE/
FTCF/
FTCT
VTCE/
VTCF
0 to 3
VTCE/VTCF: 0 to 40
300R
FTCE/
FTCF/
FTCT
VTCE/
VTCF
56
67
30R
FTCE/
FTCF/
FTCT
w/ Relief Valve
6x8
6 x 11
6x8
5.0
5.2
5.2
5.0
5.2
2 Though the max. discharge pressure of the pump is 1.0 MPa, the Relief Valve operates when 0.7 MPa is exceeded. In applications requiring a discharge pressure of 0.7 MPa or more,ask for a model w/out the Relief Valve, and install a
separate relief valve for extra safety.
Model
10N
10
30N
30
60N
60
100N
100
300N
300
600
1000
VTCE/ FTCE/
VTCE/ FTCE/
VTCE/ FTCE/
VTCE/
VTCE/ FTCE/
VTCE/ FTCE/
VTCE/
FTCF/ 6TCT
FTCF/ 6TCT
FTCF/ 6TCT
FTCF/ 6TCT
FTCF/ 6TCT
FTCT STCT
FTCT STCT
VTCF FTCT
VTCF FTCT
VTCF FTCT
VTCF
VTCF FTCT
VTCF FTCT
VTCF
Item
Max. discharge 50 Hz
30
100
10
60
300
600
1000
volume*
120
12
36
60 Hz
72
360
720
1200
(mL/min)
1.0
0.5
Max. discharge pressure* MPa
1.0
0.5
1.0
0.5
1.0
0.5
1.0
0.5
0.5
0.3
56
104
102
Stoke speed 50 Hz
(strokes/min) 60 Hz
125
67
122
0 to 2
0 to 3
Stroke length (mm)
0 to 6
Discharge side
4x9
6 x 11
6x8
6x8
6 x 11
6x8
6 x 11
6 x 8 12 x 18 12 x 15 12 x 18 12 x 15
6x8
Connection Suction side 4 x 9
(hose/tube:
4x6
4x6
4x6
4x6
4x6
I.D x O.D) Air Release
JIS 10K15A
JIS 10K15A
JIS 10K15A
JIS 10K15A
JIS 10K15A
JIS 10K15A
JIS 10K15
Flange
50 mPa.s
Max. allowable viscosity
100 mPa.s
Ambient
0 to 40
Allowable
temperature Liquid
VTCE/VTCF: 0 to 40 / FTCE/FTCF/FTCT/6TCT/STCT: 0 to 60 (no freezing allowed)
IEC529-IPX3 (water-proof)
Environmental protection
5.2 6.3
5.2 6.3
5.2 6.3
5.2 6.3
5.2 6.3
5.7 7.3
6.3 7.9
5.0
5.0
5.0
5.0
5.6
6.2
Hose 5.0
Weight (kg)
5.1
5.1
5.1
5.1
5.7
6.3
Flange 5.1
For Injection of
Boiler Chemicals
w/out Relief Valve
w/ Relief Valve
Item
Max. discharge
50 Hz
volume*1
60 Hz
(mL/min)
Max. discharge pressure*1 MPa
Stoke speed 50 Hz
(strokes/min) 60 Hz
Stroke length (mm)
Connection Discharge side
(hose/tube: Suction side
I.D x O.D) Relief Valve/Air Release
Max. allowable viscosity
Ambient
Allowable
temperature Liquid
Environmental protection
Weight (kg)
For Injection of
High-viscosity Chemicals
w/out Relief Valve
w/ Relief Valve
1000
10R 30R 60R 100R 10N 30N 60N 100N
10R 30R 60R 100R 10N 30N 60N 100N 30N 60N 100N 300N 600
VTCE
VT6E
ATCF
1000
10 30 60 100 10 30 60 100
10 30 60 100 10 30 60 100 30 60 100 300 600
1200
12 36 72 120 12 36 72 120
12 36 72 120 12 36 72 120 36 72 120 360 720
0.5
0.3
1.0
1.0
0.7*2
1.5
56
104
56
104
104
56
102
56
104
56
104
67
125
67
125
125
67
122
67
125
67
125
0 to 2
0 to 3
0 to 2
0 to 3 0 to 2 0 to 3
0 to 6
0 to 2
0 to 3
0 to 2
0 to 3
4x6
6x8
4x6
6x8
4x9
6 x 11
4x9
6 x 11
12 x 18
19 x 26
4x9
6 x 11
4x9
6 x 11
4x6
4x6
4x6
2000 mPa.s*3
1000 mPa.s*3
100 mPa.s
100 mPa.s
0 to 40
0 to 40 (no freezing allowed)
IEC529-IPX3 (water-proof)
5.0
5.0
5.7
6.3
5.1
VTCE
Pump head
Diaphragm
Check ball
VTCF
FTCE
FTCF
PVDF
PVC
FTCT
6TCT
SUS316
PTFE
STCT
SUS304
VTCE
Ceramic
O-ring
EPDM
Valve seat
Joint
Ball stopper
Ball guide
Compressed coil spring
EPDM
Fluoro-rubber
EPDM
Special fluoro-rubber
EPDM
PVC
PVC
PTFE
PTFE
PTFE
SUS316
SUS304
PTFE (valve stopper)
VT6E
ATCF
Acrylic (PMMA)
SUS316
Ceramic
PVC
EPDM
Fluoro-rubber
EPDM
PVC
Special fluoro-rubber
PVC
PVC
PVC
SUS304
Corrosion-resistance Table (0 to 40
to 20 %
to 38 %
to 60 %
to 80 %
to 98 %
to 20 %
to 80 %
Hydrochloric acid
Sulfuric acid
Acetic acid
Sodium hydroxide
Aqueous ammonia
CH3COOH
Sodium
hypochlorite
NaC O
to 12 %
to 12 %
to 30 %
to 30 %
HC
to 60 %
H2SO4
to 20 %
to 80 %
to 20 %
PVC
)
98 %
NaOH
NH4OH
to 12 %
to 90 %
to 2000 mPa.s*2
Motor Specification
1-phase
Item
50 Hz
200 V
220 V
10 W
0.30 A
0.35 A
0.59 A
0.67 A
4
Model
Output
Rated motor current
Starting current
Number of poles
100 V
120 V
0.62 A
1.22 A
0.52 A
1.00 A
230 V
240 V
100 V
110 V
0.26 A
0.51 A
0.28 A
0.54 A
0.62 A
1.12 A
0.65 A
1.26 A
60 Hz
115 V
120 V
10 W
0.59 A
0.61 A
0.92 A
0.97 A
4
200 V
220 V
0.30 A
0.56 A
0.32 A
0.64 A
400 V
440 V
0.13 A
0.36 A
0.15 A
0.40 A
3-phase
Item
50 Hz
380 V
10 W
0.15 A
0.36 A
4
Model
Output
Rated motor current
Starting current
Number of poles
200 V
346 V
0.23 A
0.56 A
0.14 A
0.33 A
400 V
415 V
200 V
220 V
0.16 A
0.38 A
0.17 A
0.40 A
0.19 A
0.53 A
0.21 A
0.58 A
60 Hz
230 V
380 V
10 W
0.22 A
0.13 A
0.61 A
0.34 A
4
Accessory
For Injection of For Injection of For Injection of
High-viscosity Sodium Hypochlorite
Boiler Chemicals
(CLCS )
Chemicals
Model
For Injection of General Chemicals
Item
Hose/Tube
VTCE/VTCF
Not available on flange model
FTCE/FTCF
FTCT
VTCE
1m
(installed only on w/ Relief Valve )
1 set (R1/2)
VT6E
ATCF
1m
Not available on 600/1000
1m
(installed only on w/ Relief Valve )
1 set (R1/2)
1 set
1 set (R1/2)
1 set
1m
( w/ Relief Valve only)
1m
( w/ Relief Valve only)
1 piece
6TCT/STCT
FEP tube (3 m) PTFE tube (3 m) PVC braided hose (1 m) PVC braided hose (3 m) PVC braided hose (3 m)
PTFE on 600/1000
Nylon tube (2 m)
1m
(
w/ Relief Valve
only)
Performance Curve
: VTCE/VTCF/FTCE/FTCF/FTCT/ATCF (CLCS ) * 1
30R
90.0
50.0
0.7 MPa
10.0
5.0
1.5
0.7 MPa
30.0
20.0
10.0
0.5
10N/10
120.0
45.0
30.0
15.0
0.5
1.5
90.0
60.0
30.0
2.5
0.5
1.5
400
0.7 MPa
300
200
100
2.5
60N/60
10.0
5.0
1.5
40.0
1.0 MPa
1.0 MPa
30.0
20.0
10.0
0.5
100N/100
90.0
0.1 MPa
0.5
0.1 MPa
0.7 MPa
50.0
0.1 MPa
60.0
30N/30
20.0
15.0
150.0
0.7 MPa
500
0.1 MPa
1.5
500
0.1 MPa
150.0
1.0 MPa
60.0
0.1 MPa
1.0 MPa
120.0
45.0
30.0
15.0
300N/300
180.0
0.1 MPa
75.0
0.5
600
1.5
90.0
60.0
30.0
2.5
0.5
1.5
2.5
400
1.0 MPa
300
200
100
1000
900
1400
0.1 MPa
750
0.1 MPa
1.5
180.0
0.1 MPa
75.0
300R
0.5
40.0
0.1 MPa
0.1 MPa
15.0
100R
20.0
60R
10R
w/ Relief Valve
0.5 MPa
600
450
300
150
0.3 MPa
1050
700
350
For performance curves for the 6TCT/STCT/VTCE (for injection of boiler chemicals),
consult TACMINA separately.
1
(A)
B
C
D
E
F
(G)
(A)
B
C
D
E
F
G
(H)
214
C
174
140
10
55
Acceptable
cable diameter
5 to 10
All models
6.5
68
120
The figure is for the VTCE/VTCF type. Sizes are as indicated above. However, the shape of
the pump head and joint differ slightly depending on model and liquid-end materials.
10
174
214
C
D
110
130
68
The shape and dimensions differ slightly depending on the liquid-end material and connection type.
For details on the external dimensions of other models, consult TACMINA separately.
Pump head
w/ Relief Valve
Main piping
Main piping
Anti-siphonal
check valve
3-way joint
Relief valve
Metering pump
Metering pump
DANGEROUS
&
COMPLICATED
Discharge side
Anti-siphonal
check valve
Relief piping
(doubles as Air Release hose)
Relief Valve
Simple Piping
Cost Saving
Easy
Maintenance
Pressure Release
Suction side
Main piping
w/ Relief Valve
Safe
CS
When abnormal pressure occurs, the relief mechanism integrated into the pump head works to automatically relieve pressure.
Related equipment
PTU
Compact design enables simple fitting into equipment and easy installation.
Just connect the power supply and piping to start operation.
Ideal layout for preventing defective discharge caused by gas lock, etc.
Large supply port for easy filling of chemicals
Reliably protected against chemicals, dirt and dust by pump cover
Entry of foreign matter prevented by suction valve w/ strainer
Easy pump removal and maintenance by slide-type pump stand*
. . . and more
Tank capacity
25 / 50 / 100 L
* 50/100 L only
Option
Flow Checker
Level Switch
Flow Indicator
CS - 30R/60R/100R/30/60/100/300
Applicable
pumps CLCS - 30R/60R/100R/30/60/100
Relief Valve
Parts Kit
Defoaming Joint
Installed on the suction
side of the pump, this joint
separates air bubbles and
fluid to prevent air bubbles
from entering the pump
head.
Solution tank
PE tank
PVC tank
The phenomenon that the force (inertia) of the discharge during chemical flow with pulsation causes chemicals to continue flowing when chemical flow should stop, resulting in excessive chemical discharge beyond the specified volume.
**12 Overfeed:
Siphoning: The phenomenon that chemicals continue to be sucked out naturally and continue flowing when the tip of the pump's discharge-side piping is lower than the level of liquid in the suction-side tank.
Product designs and specifications are subject to change without prior notice for product improvement.
Head Office:
2-4-8 Minami-Semba, Chuo-ku,
Osaka 542-0081 Japan
Tel.
+81(0)6-6271-3974
Fax.
+81(0)6-6271-4677
URL
http://www.tacmina.com
E-mail trade@tacmina.com
EC-046(2)1
ISO14001 Registration
ISO 9001 Registration
JQA1274 Production Division JQAEM0637 Production Division
2007/11/CSS