UPS

MGE Galaxy 3500 10-20kVA 400V, 3Ph In 3Ph Out, Narrow Tow er

8-11

SBP

MGE Galaxy 3500 System Bypass Panel, Wall Mount, 60kVA, 400V

12-13
14

MGE Galaxy 3500 10-20kVA, 3:3 2 MOD Narrow w ith SBP Draw ing Guide
MGE Galaxy 3500 Narrow Tow er 10-20kVA 2 MOD, SBP, 400V.

System One Line Diagram MGE Galaxy 3500 10-20kVA 400V 2MOD w ith SBP System One Line Diagram
System Wiring Diagram

MGE Galaxy 3500 10-20kVA 400V 2MOD w ith SBP System Control Wiring Diagram

15kVA

20kVA

2 x G35T15KH2B2S

2 x G35T20KH2B2S

T ota l N o . of
b a t t e ry
m o d u le s

10kVA

Battery
Modules in
UPS(SYBT4)

2 x G35T10KH1B2S

2 x G35T10KH2B2S

Net
Net
Net
Net
Weight in Runtime in Weight in Runtime in Weight in Runtime in Weight in Runtime in
Kg
Min
Kg
Min
Kg
Min
Kg
Min

428

N.A

N.A

N.A

N.A

N.A

N.A

612

18

612

18

804

10

804

Rating
10kVA
15kVA
20kVA

SKU Number
G35T10KH1B2S
G35T10KH2B2S
G35T15KH2B2S
G35T20KH2B2S

COG Details in mm
X-Distance Y-Distance Z-Distance
176
655
400
176
650
398
176
650
398
176
650
398

Galaxy 3500 10K and 40K UPS Frame (2 Module) Site Planning Data - with MBP
Battery - Nominal Voltage : +/-192V DC
Input and output Voltage : 400V AC
System Mains Input

UPS Rating

G35T10KH1B2S
G35T10KH2B2S
G35T10KH1B4S
G35T10KH2B4S
G35T10KH3B4S
G35T10KH4B4S
G35T15KH2B2S
G35T15KH2B4S
G35T15KH3B4S
G35T15KH4B4S
G35T20KH2B2S
G35T20KH2B4S
G35T20KH3B4S
G35T20KH4B4S
G35T30KH3B4S
G35T30KH4B4S
G35T40KH4B4S

Maximum
Current(A)

Nominal
Current(A)

Recom m ended Over current Protection


Device Ratings

System Output

SKU Number
Nominal
Current(A)

10kVA/8kW

System
Bypass
Input

System output
Power

Nominal
Current(A)

Battery
Current(A)
(in UPS
Cabinet)

UPS Mains
Input (A)

UPS
Bypass
Input (A)

Floor
Typical
UPS
weight
Loading
Dimensions
(Kg) see
System
data in
H x W x D (mm)
Output (A)
Note 14
see note 14
Kg/m2

24.6

27

28.8

10kVA/8kW

28.8

27.5

16

16

16

37

40.6

43.4

15kVA/12kW

43.4

41.2

25

25

25

49.4

54.4

57.8

20kVA/16kW

57.8

55

32

32

32

73.4

80.6

86.6

30kVA/24kW

86.6

82.5

50

50

50

40kVA/32kW
98.2
108
115.4
40kVA/32kW
115.4
110.1
63
63
Notes.
1. Nominal Input current based on nominal mains voltage + batteries fully charged at 100% ohmic load.
2. Maximum Input current based on fully battery recharge + nominal mains voltage at 100% ohmic load.
3. Suggested input overcurrent protection based on continuous full load.
4. Nominal battery voltage assumed to be 2.0 volts/ cell (lead technology)
5. Over current protection device rating selection based on Nominal input current is acceptable provided battery recharge time is short.
Consult Schneider Electric for application specific assistance.
6. Voltage tolerance is 304 - 477V, 47 - 53Hz nominal 50Hz.
7. Input power-factor is > 0.98 for > 50% loading.
8. Cable installation to comply with EN60364-5-52, max ambient 30 deg C, cable sizes shown
refer to 600V rated,90 degree C multicore copper conductors with thermosetting insulation unless otherwise mentioned
9. AC input & output to be L1, L2, L3, N & PE depending on 400/230V configuration, PE may be separate or SWA of armored cable
10. Overcurrent protective devices (OCPD) may be either gL fuse type or MCB/MCCB rated at 30kA fault rating
11. DC cabling should be sized to give < 1% voltage drop at the nominal battery discharge current
using three-wire separate conductors in positive, centre-tap and negative poles
12. Top or bottom cable entry with removable gland plates
13. Control wiring to be run separately using screened conductors away from power cabling preferably in a separate conduit or cable tray
14. Weights and dimensions are with internal batteries, with extended battery cabinets use battery discharge current
in conjunction with cable drop to size cabling from cabinet to UPS
15. Heat loss refers to max loading and fully charged batteries
16. Refers to maximum battery recharge conditions
17. Input : THD < 5% at Full Load
18. Input : THD < 1.5% Linear Load, <3.5% Non Linear Load

63

15kVA/12kW

20kVA/16kW

30kVA/24kW

SYSTEM
10KVA 400V
15KVA 400V
20KVA 400V
30KVA 400V
40KVA 400V

EFFICIENCY DETAILS
25% LOAD 50% LOAD 75% LOAD 100% LOAD
92.9
94.8
94.9
94.9
92.9
95.3
95.5
95.5
94.4
95.5
95.5
95.4
94.1
96
95.9
96.1
95
96
95.9
95.5

UPS Mechanical Data

1491x352x838
1491x352x838
1491x523x838
1491x523x838
1491x523x838
1491x523x838
1491x352x838
1491x523x838
1491x523x838
1491x523x838
1491x352x838
1491x523x838
1491x523x838
1491x523x838
1491x523x838
1491x523x838
1491x523x838

214
306
351
443
535
627
402
443
535
627
402
443
535
627
570
662
662

725
1037
801
1011
1221
1431
1363
1011
1221
1431
1363
1011
1221
1431
1301
1510
1510

Heat
Loss /
watts
See
Note 15

440

516

751

839
1279