You are on page 1of 2

notice dry contact

10/03/03

16:23

Page 1

Ref.5006405A

INSTALLATIONguide
inteo

DRY CONTACT TRANSMITTER

The DRY CONTACT TRANSMITTER is a RTS control that can be controlled driven by a key switch, a paddle switch, a Centralis IB or a dry contacts rain sensor.
The UP or DOWN radio commands are achieved when the UP or DOWN inputs ( ) are connected with the common input (C). The STOP command is achieved when the three inputs ( C)
are conected together.

Characteristics

Built-in manual
security control

Supply : 220-240V 2,5A 50/60Hz


Fuse : 3,15A
Transmission timing : min0,5 sec.
max10 sec.
Frequency : 433.42 MHz
Protection index : IP30
Temperature : +5C to +40C

PROG

80 mm

Programing
button
LED

45 mm

,S,,S
R

80 mm

Hereby, SOMFY, declares that this


equipment is in compliance with the
essential requirements and other relevant provisions of Directive 1999/5/EC.
A Declaration of Conformity is available
at the web address www.somfy.com
Heading CE

usable in EU, CH

Class II product

Installation
This device must be installed and programmed by qualified installers for whom this instruction is intended. Before connecting the unit, read the instructions carefully.

Cabling of a CENTRALIS IB

MAINS
230V - 50Hz

2 x 1,5 mm2

Neutral
Phase

+
-

5 4 3

Set the switch on

the "-" position


C

CENTRALIS IB

= UP
= DOWN

NL

SUPPLY
230V 50Hz
Phase
Neutral
Earth

Dry contacts TRANSMITTER

MAINS
230V - 50Hz

Cabling of a Key switch

2 x 1,5 mm2

Brown
Blue
3

2 1

L = Mains phase
N = Mains neutral
C = common

Brown
Blue

KEY SWITCH

We reserve the right to make changes due to technical improvements.

NL

Dry contacts TRANSMITTER

Neutral
Phase

L = Mains phase
N = Mains neutral
C = common
= UP
= DOWN

5 4 3
C

SUPPLY
230V 50Hz
Phase
Neutral
Earth

DRY CONTACT TRANSMITTER

2 1

notice dry contact

10/03/03

16:23

Page 2

Cabling of a rain sensor


MAINS
230V - 50Hz

2 x 1,5 mm2

Earth

Rain sensor

Neutral

Rain sensor

OR

Phase

Brown
Blue

Brown
Blue

RAIN SENSOR

L = Mains phase
N = Mains neutral
C = common

yellow/green
brown

= UP
= DOWN

NL

blue

yellow/green
brown

blue

blue

brown

blue
brown

Dry contacts TRANSMITTER


5 4 3

2 1

5 4 3

SUPPLY
230V 50Hz

Mounting

2 1

SUPPLY
230V 50Hz

Phase
Neutral
Earth

Phase
Neutral
Earth

RECESSED mounting

2x

Screw the support on the


recessed box.

Complete the cabling and clip


the receiver on the support.

Clip the front cover.

SURFACE mounting

2x

3
A

Screw the flush mounting box


onto the wall.

2x

Screw the support on the box.

Complete the cabling and clip


the receiver on the support.

Programming

INITIAL INSTALLATION To record the first DRY CONTACT TRANSMITTER

Set the RTS receiver in its programming mode (refer to the relevant instruction guide).
Press the programming button on the frontside of the DRY CONTACT TRANSMITTER RTS until the
reaction of the RTS receiver (blinking of a light or movement of the end-product). The address of the
transmitter is memorized by the RTS receiver which automatically quits its programming mode.

Clip the front cover

Programing
button
LED

PROG

,S,,S
R

EXISTING INSTALLATION To add a new DRY CONTACT TRANSMITTER

Press more than two seconds on the programming button of a RTS transmitter already memorized in the RTS receiver in order to wake
up the receiver.
Record the new control by pressing the programming button on the frontside of the transmitter until the reaction of the RTS receiver (blinking of a light or movement of the end-product).
The address of the transmitter is memorized by the RTS receiver which automatically quits its programming mode.

C DELETE A DRY CONTACT TRANSMITTER


Carry out the same procedure as described in chapter 3A :
Set the RTS receiver in its programming mode, then press the prog button of the transmitter you wish to delete.

DRY CONTACT TRANSMITTER

We reserve the right to make changes due to technical improvements.


SOMFY SAS, capital 20.000.000 Euros, RCS Bonneville 303.970.230

You might also like