The Idle Shutdown Timer will shutdown the engine if it remains idling for a specified period of
time. The options that can operate with Idle Shutdown Timer are Idle Shutdown Override, Vehicle
Power Shutdown or Shutdown on Variable Speed Governor (VSG).
5.8.1
OPERATION
Certain conditions must be met for the entire time-out period for shutdown to occur. These
conditions include:
Coolant temperature above 14 F (10 C)
Engine operation at idle
The parking brake interlock digital input switched to battery ground
OEM supplied interlocks enabled
Ignition ON
Fueling is stopped after the specified idle time; the ignition circuit remains active after the engine
shuts down. The AWL will flash 20 seconds before the shutdown occurs. The RSL will flash 10
seconds before shutdown occurs. The AWL will blink until the ignition is turned off to indicate
shutdown has occurred. The ignition switch must be cycled to OFF (wait 10 seconds) and back to
ON before the engine will restart, if shutdown occurs.
5-63
FEATURES
A Park Brake Switch must be installed (see Figure 5-13). Idle Shutdown Timer operates with a
digital input configured as a park brake and switched to battery ground. The time can range from
1 to 1000 seconds (approximately 16 minutes).
Figure 5-13
5-64
Figure 5-14
All electrical loads that should be turned OFF when the engine shuts down should be wired
through this relay.
5-65
FEATURES
5.8.2
To program the Idle Shutdown timer, the digital input listed in Table 5-43 must be configured.
Description
Pin
Park Brake
Table 5-43
21/16
Type
Setting
Default
Parameter ID
Digital Input
0 = Disabled
1 = Enabled
1 13 07
The Idle Shutdown timer options listed in Table 5-44 can be programmed by VEPS or minidiag2.
Parameter
IDLE SHUTDOWN
ENABLED
IDLE SHUTDOWN TIME
(MIN)
ENABLED VSG
SHUTDOWN
Table 5-44
5-66
Description
Choice / Range
Default
Parameter
ID
0 = Disable
1 = Enable
1 02 01
1 to 1000 seconds
60 sec
1 02 02
0 = Disable
1 = Enable
1 02 03
1 to 1000 seconds
60 sec
1 02 04
3120 sec
20 sec
1 02 06
3120 sec
10 sec
1 02 07
-40 C to 200 C
-10 C
1 02 08
0 = Disable
1 = Enable
1 02 09