Characteristic
Fast software interrupt timing is 0.25ms apply to control, enhance the accuracy of more
than 2 times the displacement
It is simple to update all of program via USB memory driver
DCS control (HMI and Remote I/O module) for easy access of external device and/or
controller
Various HMI size options: 5.6", 8", 10.4" and 12.1" or touch panel(10.4" & 12.1")
3 of high speed 32 bits CPU (266MHz)
High speed Ethernet communication between HMI and Remote I/O module
RS485 and SKY-Link(Option) Interface
State-of-the-art window system HMI Screen Editor design by ARICO
PLC ladder editor for process program
The Demolished architecture, CPU board can be upgraded to more powerful new one on
base main control board
It is non-industrial personal computer board, because the CPU of PC update very fast,
face stop manufacture and version change, software maintain and cost will go high
I/O function define self and shift function
(1) Change the defect I/O to another by setting, to solve problem at once
(2) For some multi function valve, use program control them, it can use one program
to apply the timing of the different hydraulic valve in extent permitted
(3) For some multi function valve, use program control them, and collect them to front
I/O to save the I/O ports (D/O have to consider the 2A/port, 16 ports max. is 10A)
(4) Define different D/ID/OA/IA/O for different model machine, no need to modify
the wiring, just setting to suitable hardware(example: it can be applied at old
machine replace new controller, no need re-wire the all wires)
Flip up icon of screen and alarm message
PLC Real-Time control
The 10 levels control for user
The present screen picture can be saved via USB port to external memory device (USB
memory device)
Back to Contents
Injection Curve
Operation Record
Temperature Curve
Back to Contents
Standard
Standard
Digital
Input port
Digital
Output port
8"
32 ports
32 ports
Mechanical Keys
FDA Output
Port (0~10V)
Temperature
IN(TC)
5 channels
8 zones
Heater
Output(HT)
6 channels
RPM Count
Ethernet
64 keys
USB Host port
1 port
8 zones
Extended module
1 port
Module Memory
Digital
Input port
Option
100 sets
RS-485, 2 line
1 port
+8 ports
Digital
Output port
+2 channels
+8 ports
Extended Module
Option
TFT LCD Size
5.6"/10.4"/12.1"
SKY-Link
W207.3mm H345mm
RS-485
Temperature
IN(TC)
Cooling
output(CL)
8 zones
8 zones
1 set
Heater
Output(HT)
Touch Panel
8 zones
RS-485
Temperature of
15 groups can
be cascaded I/O
10.4"
Extended Keys
64 keys
RS-485, 4 line
1 port
Back to Contents
HMI
Standard
Standard
Digital
Input port
Digital
Output port
32 ports
32 ports
8 channels
8 channels
1 port
Module Memory
FDA
Output Port
(0~10V)
Temperature
IN(TC)
100 sets
10 channels
13 zones
RS-485, 2 line
RPM Count
Heater
Output(HT)
1 port
4 ports
13 zones
W209mm H393.4mm
Ethernet
Servo control
Extended
Module
Encoder
Input port
8 channels
MagBridge
Option
TFT LCD Size
(+16/+16)or(+32/+32)or(+48/+48)or(+64/+64) ports
8 channels
Encoder 32 bit
(+16/+16)or(+32/+32)or(+48/+48)or(+64/+64) ports
4 channels
5.6"/10.4"/12.1"
(+16/+16)or(+32/+32)or(+48/+48)or(+64/+64) ports
SKY-Link
1 set
Touch Panel
10.4"
Extended Module
Extended Keys
64 keys
RS-485, 4 line
1 port
RS-485
Temperature
IN(TC)
Cooling
output(CL)
8 zones
8 zones
Heater
Output(HT)
Temperature
of 15 groups
RS-485
can be
cascaded
I/O
8 zones
Back to Contents
HMI
W243mm H356mm
Standard
Standard
TFT LCD Size
Digital
Input port
Digital
Output port
8"
32/48 ports
32/48 ports
FDA Output
Port (0~10V)
6 channels
4 channels
PWM Output
RPM Count
1 port
1 port
Option
Temperature
IN(TC)
Heater
Output(HT)
8 zones
8 zones
Mechanical Keys
Ethernet
64 keys
USB Host port
1 port
Module Memory
100 sets
RS-485, 2 line
CAN
1 port
4 channels
S/S Interface
1 set
4 sets
MagBridge
Option
TFT LCD Size
5.6"/10.4"/12.1"
(+16/+16)or(+32/+32)or(+48/+48)or(+64/+64) ports
SKY-Link
1 set
Touch Panel
(+16/+16)or(+32/+32)or(+48/+48)or(+64/+64) ports
10.4"
Extended Module
Extended Keys
64 keys
RS-485, 4 line
1 port
RS-485
Temperature
IN(TC)
Cooling
output(CL)
8 zones
8 zones
Heater
Output(HT)
Temperature
of 15 groups
RS-485
can be
cascaded
I/O
8 zones
Back to Contents
HMI
W243mm H386mm
Standard
Standard
Digital
Input port
Digital
Output port
32/48 ports
32/48 ports
8 channels
8/12 channels
RPM Count
Temperature
IN(TC)
100 sets
3 ports
8 zones
Extended Module
RS-485, 2 line
CAN
Heater
Output(HT)
Encoder
Input port
1 port
1 set
8 zones
8 channels
Ethernet
MagBridge
Option
TFT LCD Size
5.6"/10.4"/12.1"
SKY-Link
1 set
Servo control
Encoder
Extended Module
A/D Input Port
16 bit, range:
0~10V
(+16/+16)or(+32/+32)or(+48/+48)or(+64/+64) ports
I/O Extended Module #5~#8
(+16/+16)or(+32/+32)or(+48/+48)or(+64/+64) ports
8 channels
Encoder 32 bit
(+16/+16)or(+32/+32)or(+48/+48)or(+64/+64) ports
4 channels
Touch Panel
10.4"
Extended Module
Extended Keys
64 keys
RS-485, 4 line
1 port
RS-485
Temperature
IN(TC)
Cooling
output(CL)
8 zones
8 zones
Temperature
of 15 groups
RS-485
can be
cascaded
Heater
Output(HT)
I/O
8 zones
Back to Contents
HMI
HMI CPU
266MHz
Internet Connection
(Optional)
Yes
Able to expand with an Ethernet card
Yes
Touch Panel
(Optional)
AR1260
AR1860
PLC CPU
AR2000
AR2100
266MHz
266MHz
Time base = 0.25ms
Control CPU
IO Connection
NPN
NPN
NPN
PNP
Temperature
PID Control
13
32
32
32 / 48
32 / 48
32
32
32 / 48
32 / 48
14 bit * 6
16 bit * 8
16 bit * 6
16 bit * 8
Start/Stop Input
0/4/8
12 bit *
5(0~+10v)
12 bit *
10(0~+10v)
12 bit *
4(0~+10v)
12 bit *
0/2(0~10v)
12 bit *
8(0~10v)
12 bit *
0/4(0~10v)
12 bit *
8/12(0~10v)
PWM Output
RPM Count
FPGA
PLC CPU & Control CPU data transmitted through a parallel FPGA
connection; allows more precise control accuracy
10
Back to Contents
AR1260
AR1860
AR2000
AR2100
Temperature
Module
IO Expansion
Module
DI / DO*8(Max)
AD/Encoder
Compound Module
AD 16 bit*8
Encoder 32 bit*4
AD 16 bit*8
Encoder 32 bit*4
Encoder
32 bit * 8
32 bit * 8
HMI Dimension
5.6"
8"
10.4"
H370.6W193 mm
H417.8W237.5 mm
H469.1W 285 mm
H507.9W237.5 mm
Multi-Injection
molding 10.4"
12.1"
H505.3W288.9 mm
H517.8W332 mm
H244.8W287.6 mm
H196W257 mm
Note: 5.6" is VGA (640x480); other LCD modules are all SVGA (800x600)
11
Back to Contents
1. XP System:
CPU: Intel Core i3 or above
RAM4G
HARD DISK1TB
2. WIN7 64 bit system:
CPU: Intel Core i5 or above
RAM: 8G or above
HARD DISK1TB
3. HUB: 10/100Mbs high speed Ethernet
switch
4. Network cable specification CAT.6 or
above
1. Operating System:
XP Professional or Window 7
Professional 64 bit
2. IIS information services installation
required (if external webpage browsing
needs to be permitted, MIS needs to
set the real IP and communication port)
3. Local area network properties must
include Client Microsoft Networks and
TCP/IP
4. Office 97 or above (Excel must be
installed)
5. Framework 4.0 or above
System Architecture
Machine 01
Machine 02
Machine 09
Machine 10
Machine xx
Machine xx
HUB
HUB
Tablet
computer
Manufacture
Department
PC
Production
Insurance
Section PC
12
Manager
Computer
Mobile phone
Back to Contents
13
Back to Contents
(connect HMI)
24V
E DI O- 0 1
E DI O- 0 2
I N
(extension)
24V
OUT
1 9 1 9
CN 1
2 10 210
3 11 311
ETC-08
4 12 412
6 14 614
1 1
CN 1
Run
2 2
7 15 715
4 4
CN 2
1
2
3
4
1 1
2 2
3 3
4 4
Tx
5 5
HT
6 6
CL
7 7
8 8
5 5
Rx
HT
CN 2
1
2
9
HT
5
6
7
8
5
5
6
6
7
7
8
8
AR1860 / AR2100
S1 ~8
1
2
3
CL 4
5
6
7
8
G
NC
12V
4
5
6
7
8
1
2
3
CL 4
5
6
7
8
G
G
G
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
NC
12G
FG
12G
FG
Expansion Board
1 2 3 4 5 6 7 8
12V
Rx
1
2
HT
4
4
Main Board
Tx
24V
3
3
ON
S1 ~8
1 2 3 4 5 6 7 8
G
G
ON
Run
Debug1
Debug2
CN 2
1
1
2
2
24V
6
7
10
11
12
13
14
15
16
6 6
CL
7 7
8 8
TC
TC
12V 24V
CN 1
Debug1
Debug2
3 3
8 16 816
ETC-08
12V 24V
5 13 513
(Cable Standard= 5m or
(Cable Standard=
___m)
0.45m)
AR1260
A3
A5
A7
A1
A3
A5
A7
B1
B3
B5
B7
A
1
B
1
B1
B3
B5
B7
Z1
Z3
Z5
Z7
Z1
Z3
Z5
Z7
A2
A4
A6
A8
A2
A4
A6
A8
B2
B4
B6
B8
B2
B4
B6
B8
Z2
Z4
Z6
Z8
Z2
Z4
Z6
Z8
VI 33 35 37 39
G I34 36 38 40
ED I-S08
Line Driver
Open Collector
AR1860
AR1260
Source,NPN
Sink, NPN
Source,NPN
Sink, NPN
Sink,PNP
Source, PNP
Sink,PNP
Source, PNP
14
Back to Contents
Other Accessories
FPV-01
FPV-01N
ARPV-01
ARPV-04
AC Auxiliary Power
15Vac/0Vac/15Vac
AC Input Power
50Vac(40)/24Vac(10)
DC Auxiliary Power
24Vdc
DC Input Power
Power Output(Max.)
25.6W(40) / 6.4W(10)
Jumper Select
Load Impedance
40/10
10
Output Current(Max.)
0.8A
4A
48Vdc
160W
0~10 Vdc
Fuse
2A
5A
Vibration Frequency
120 Hz
Ascending Speed
Descent Speed
Output Value(Max.)
Output Value(Min.)
Fine
Adjustment
(25 rpm)
Control Input
Control Output
Relay-04
Fine
Adjustment
(25 rpm)
12A
Nominal Voltage
15mA
10mA 5VDC
Nominal Current
15mA
Max. Allowable
Voltage
250VAC/30VDC
Pick Up Voltage
>18VDC
Rated Load
12A/120VAC
10A/24VDC
10A/240VAC
<2.4VDC
Max. Applicable
Voltage
26.4VDC
Operate Time
10ms
Release Time
5ms
Power Consumption
0.36W
15
Back to Contents
Specification
DC Voltage
Rated Current
Current Range
Rated Power
OUTPUT
INPUT
Voltage Range
Frequency Range
Efficiency(Typ.)
AC Current(Typ.)
Inrush Current(Typ.)
ENVIRONMENT
PROTECTION
Leakage Current
note. 7
Over Load
Over Voltage
Work Temp.
Working Humidity
Storage Temp., Humidity
Temp. Coefficient
Vibration
Safety
Standards note. 6
12V
3A
0~3A
36W
12mVp-p
10.8~13.2V
1.0%
0.5%
0.5%
500ms, 30ms/230VAC
1200ms, 30ms/115VAC(at full load)
50ms/230VAC
10ms/115VAC (at full load)
85~264VAC 120~370VDC
47~63Hz
81%
0.75A/115VAC 0.5A/230VAC
Cold Start: 45A
<2mA/240VAC
110%~150% rated output power
Derating Curve
13.8~16.2V
Withstand Voltage
Isolation Resistance
EMC Emission
EMC Immunity
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. For the request of GB4943.1, the power supply is only suitable for use in the altitude 2000m below and the non tropical climate condition.
7. The power supply is considered a component which will be installed into a final equipment.
The final equipment must be re-confirmed that is still meets EMC directives.
16
Back to Contents
Features:
AC input range selectable by switch
Protections: Short circuit/Overload/Over voltage/Over temperature
Forced air cooling by built-in DC fan
Withstand 300VAC surge input for 5 second
Built-in cooling Fan ON-OFF control
Built-in constant current limiting circuit
100% full load burn-in test
LED indicator for power on
Fixed switching frequency at 90KHz
Low cost, high reliability
OUTPUT
Specification
DC Voltage
Rated Current
Current Range
Rated Power
Ripple & Noise(max.) note. 2
Voltage Adj. Range
Voltage Tolerance note. 3
Line Regulation
Load Regulation
Setup, Rise Time
Hold Up Time(Typ.)
INPUT
SAFETY
ENVIRONMENT
FUNCTION
PROTECTION
Over Load
Over Voltage
Over Temperature
24V
14.6A
0~14.6A
350.4W
150mVp-p
20~26.4V
1.0%
0.5%
0.5%
1000ms, 50ms/230VAC
1000ms, 50ms/115VAC(at full load)
20ms/230VAC
16ms/115VAC(at full load)
90~132VAC/180~264VAC
(selected by switch) or 254~370VDC
47~63Hz
87%
7A/115VAC 4A/230VAC
40A/115VAC 60A/230VAC
<3.5mA / 240VAC
105~135% rated output power
Static Characteristics
27.6 ~ 32.4V
Work Temp.
Working Humidity
Storage Temp., Humidity
Temp. Coefficient
Vibration
20~90%RH non-condensing
-40~+85C, 10~95%RH
0.03%/C(0~50C)
Safety Standards
UL60950-1 approved
Withstand Voltage
Isolation Resistance
Derating Curve
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Please connect positive pole of input voltage with mark "L" of terminal block, connect negative pole of input voltage with mark "N" of
terminal block, using DC voltage for input voltage.
17
Back to Contents
OUTPUT
Specification
DC Voltage
Rated Current
Current Range
Rated Power
Ripple & Noise(max.) note. 2
Voltage Adj. Range
Voltage Tolerance note. 3
Line Regulation note. 4
Load Regulation note. 5
Setup, Rise Time
Hold Up Time(Typ.)
INPUT
Frequency Range
Efficiency(Typ.)
AC Current(Typ.)
Inrush Current(Typ.)
Leakage Current
PROTECTION
Voltage Range
Over Load
Over Voltage
ENVIRONMEN
T
Work Temp.
Working Humidity
Storage Temp., Humidity
Temp. Coefficient
Vibration
note. 7
48V
2.3A
0~2.3A
110.4W
150mVp-p
45.6~52.8V
1.0%
0.5%
0.5%
1000ms, 20ms/230VAC
1000ms, 20ms/115VAC(at full load)
30ms/230VAC
25ms/115VAC(at full load)
85~132VAC/176~264VAC
(selected by switch) or 248~373VDC
47~63Hz
86%
2A/115VAC 1.2A/230VAC
Cold Start: 45A
<2mA/240VAC
110%~150% rated output power
Deration Curve
Static Characteristics
55.2~64.8V
Withstand Voltage
Isolation Resistance
EMC Emission
EMC Immunity
Compliance to EN61000-4-2,3,4,5,6,8,11,
EN55024, EN61000-6-1, light industry level, criteria A
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. For the request of GB4943.1, the power supply is only suitable for use in the altitude 2000m below and the non tropical climate condition.
7. The power supply is considered a component which will be installed into a final equipment.
The final equipment must be re-confirmed that is still meets EMC directives.
8. Please connect positive pole of input voltage with mark "L" of terminal block, connect negative pole of input voltage with mark "N" of
terminal block, using DC voltage for input voltage.
18
Back to Contents
2.
3.
4.
19
Back to Contents
1.
2.
Auto/Manual function
3.
4.
5.
6.
7.
8.
9.
20
Back to Contents
6 Zones (3 Modules)
12 Zones (6 Modules)
21
Back to Contents
Products Overview
GEFRAN AGENT & OTHER PRODUCTS
Melt pressure
Transducers
M3/W3/K3 Series
ME/WE/KE Series
MN/WN/KN Series
MD/WD/KD Series
MX/WX Series
MX4
MF/WF Series
M6/W6 Series
IE1/IN1/I3
IX
M50
M51
M52
Pressure
KS
TK
TKDA
TSA
TPS
TPSA
TPSADA
TPF
Transducers
TPFADA
TPH
LT
Displacement
PC
TPHADA
PK
XPSA
PA1
XSA
TDP
PZ Series
PME12
PMI12
PMISL
PMISLE
PMA12
LT67
PC67
PZ67A
PZ67S
ONP1-A
PY Series
IC
PCIR
Transducers
MK4 Series
Encode
IK4 Series
Controller / Alarm
unit / Programmer
RK2 Series
PS Series
EG
400
401
600
1000
1001
1101
4T48
4T96
40B48
40T72
40B96
40TB
2300
2308
2400
2500
/ Indicator
Ceramic Band
Heater
Ceramic Band Heater
Products Overview
Temperature
Controllers
V Series
Temperature
Controllers
C Series
Temperature
Controllers
A Series
Temperature
Controllers
TC Series
V100
V200
V300
V400
V500
C100
C200
C300
C400
C500
A1AN
A2DD
A3AA
A3DA
A3DD
A4DA
A4DD
TC2DA
TC3AO
TC3AA
TC3DA
TC3DD
TC4AA
TC4DD
Hot Runner
Temperature
Controllers
TC5H Series
Multi-Cavity
Hot Runner
Temperature
Controllers
TC5E Series
Valve gate
Controller
TC5200
TC5100
TC500
TC5V Series
Plastic Machine
Controllers
AR1260
AR1860
AR2000
AR2100
AR Series
ARD48 Series
ARV24 Series
ARA24 Series
Signal
transmitter
Heatsoft
SY Series
SV Series
SW Series
23
ARA48 Series
SB Series
TR100
Back to Contents
DISTRIBUTORS
Headquarters
23145 235 1 1 8
8F., No. 1, Alley 1, Lane 235, Baoqiao Rd.,
Xindian Dist., New Taipei City 23145, Taiwan
TEL:+886-2-2910-1266
FAX:+886-2-2915-9434
info@arico.com.tw
www.arico.com.tw
Taipei Factory
TEL:+886-2-2910-1077
FAX:+886-2-2910-1056
Taichung Branch Dong Guan
TEL:+886-4-2291-7011
TEL:+86-769-8390-2101~3
FAX:+886-4-2292-4021
FAX:+86-769-8398-8791
Tainan Branch
TEL:+886-6-253-9940
FAX:+886-6-253-9945
Shanghai
TEL:+86-21-6111-5256~9
FAX:+86-21-6227-0065
24
Back to Contents
ARICO Technology Co., Ltd. Reserves the right to make any kind of design or functional modification at any moment without prior notice.