The following underground structures and above ground structure are protected by SACP

system
No.

1
2
3

Descriptio
n

Locatio
n

Outside

Length

Pipe
Operating
Temperature

Coating Type

Diameter
Closed Drain (DC/TD/WP) & Amine Drain (AD) Pipes
PE Wrapping
Pipe 4"
U/G
4.5"
865 m
Tape
PE Wrapping
Pipe 3"
U/G
3.5/'
100 m
Tape
PE Wrapping
Pipe 2"
U/G
2.375"
345 m
Tape

30C
30C
30C

Magnesium Anode Chemical


Composition
Element
Content (%)
Alumunium (Al)
5,3-6,7 max
Zinc (Zn)
2,5-3,5 max
Manganese (Mn)
0,15-0,70 max
Silicon (Si)
0,30 max
Copper (Cu)
0,005 max
Iron (Fe)
0,03 max
Nickel (Ni)
0,003 max
Others
0,30 max
Magnesium (Mg)
Balance

Magnesium Anode Characteristic


Anode Characteristic
Desian Life Time (years)
Open Circuit Potential (volt) *
vs Cu/CuS04 in soil/fresh water
Closed Circuit Potential (volt) **
vs Cu/CuS04 in soil/fresh water
Driving Voltage (volt)
Anode Current Capacity (A-Hr/kg) *
Design Utilization Factor(%)
Anode Shape
Anode Dimension
Length (mm)
width (mm)
Height (mm)
Length with backfill (mm)
Diameter with Backfill (mm)
Gross Weight (kgs)
Net Weght (kgs)

Onshore Pipe
25
-1,5
-1,4
0,65
1,1
0,8
Prepackaged
620
90
95
750
150
Appr. 17
7,7

DESIGN CALCULATION
1. Area To Be Protected
Area to be-protected is calculated as follow :
A = 1t x D x L x CB

(Underground Pipe)

Where A = Area to be protected (m2)


D = Outside diameter of pipe (m)
L = Length of pipe (m)
Cb = Estimate Coating Breakdown (5% for wrapping tape)

No.

Protected Stucture

Outside
Diameter

1
2
3

Closed Drain
(DC/TD/WP)
& Amine Drain (AD)
Pipes
Pipe 4"
Pipe 3"
Pipe 2"

Protecte
d
Length

0,1143 865 m
0,0889 100 m
0,0603 345 m

Estimate
Coating
Breakdown

5%
5%
5%

Protected
Area
(m2)

30C
30C
30C

Protective Current Requirement


The current requirement for protecting the object is calculated as follow
Ip = A x Cd x (1+ SF)
Cd= Cd30 + Cd30 x (Tp- 30) x i/10
Ip = Protective current requirement
A
= Area to be protected
Cd30 = Bare Steel Current density at 30C
i = Increment of Bare Steel Current density at temperature
Tp = Average Temperature of Pipes
Cd = Bare Steel Current density at TpC
SF= calculation safety factor

Protected
No.

1
2
3

Protected Stucture
Closed Drain
(DC/TD/WP)
& Amine Drain
(AD) Pipes
Pipe 4"
Pipe 3"
Pipe 2"

Current
Density

Calculation
Safety

Pipe Opr.

Area
(m2)

(A/m2)

Factor (%)

Temp.
('C)

15,53
1,4
3,27

0,06
0,06
0,06

10
10
10

30
30
30

Required Prot.
Current
(Ampere)

1,025
0,092
0,216

Weight of Anode
The weight of anode is calculated based on total required protective
current, design life time, anode current capacity, and utilization factor as
per following formula:
Ix L x 8760
W=uxC

No
.

1
2
3

Protected Stucture

Require
Prot.

Dsn.
Life
Time

Utilization

Anode
Current

Current
(Ampere
)

(Years)

Factor

Capacity
(AmpHr/kg)

Net Weight
(kgs)

0,8
0,8
0,8

1100
1100
1100

255,09
22,94
53,7

Closed Drain
(DC/TD/WP)
& Amine Drain (AD)
Pipes
Pipe 4"
1,025
25
Pipe 3"
0,092
25
Pipe 2"
0,216
25
Where
W = required anode net weight
I = required protective current
L = anode design life time

8760 = conversion factor for year to hour


u = anode utilization factor
C = anode current capacity

Required
Anode

No.

1
2
3

Protected Stucture
Closed Drain
(DC/TD/WP)
& Amine Drain (AD)
Pipes
Pipe 4"
Pipe 3"
Pipe 2"

Net weight (kgs)

Individual Anode
Net
Weight (kgs)

Calculated
Number of
Anode (pcs)

255,09
22,94
53,7

7,7
7,7
7,7

34
3
7

Require Anode

Require
Prot.
No
.

1
2
3

No.

Protected Stucture
Current
(Ampere)
Closed Drain
(DC/TD/WP)
& Amine Drain (AD)
Pipes
Pipe 4"
Pipe 3"
Pipe 2"
Total

Protected Stucture
Closed Drain
(DC/TD/WP)

1,025
0,092
0,216

Protected
Length
(m)

Calculated
Number of
Anode (pcs)
Curre
nt
Weight
Metho method
d

9
1
2

34
3
7

Deisgn
Number of
Anode (pcs)

Design
Number of
Anode (pcs)

34
3
7
44

Anode
Spacing
(m)

1
2
3

No.
A

& Amine Drain (AD)


Pipes
Pipe 4"
Pipe 3"
Pipe 2"

Parameter
Design
Parameter
Design Life
1 Time

34
3
7

865
100
345

symbo
l

Formula

---

Unit

25
33
50

Value

25

Value

25

Va

2
3
4
5
6
B
1
2
3
4
5
6
7
C

2 CP Criteria
(vs CSE)
Average Soil
Resistivity
Soil
Corrosivity
Bare Steel
Current
Density
Calculation
Allowance
Factor
Pipe &
Coating Data
U/G Pipe
Description
Pipe Outside
Diameter
U/G Pipe
Protected
Length
Pipe Coating
type
Joint Pipe
Coating Type
Estimate
Coating
Breakdown
Portected
Surface Area

Ep

---

Volt

----

ohm.cm

----

----

----

SF

amps/m
2

-0,85

-0,85

-0

1000

1000

10

Extrimely
Corrosive

Extrimely
Corrosive

0,06

0,06

0,

10%

10%

10

Pipe d=4" x
865m

Pipe d=3"
x 100m

Extri
Corr

----

OD

Lp

0,1143

Pipe
x3

0,0889

0,0

100
Wrapping
tape
Wrapping
tape

3
Wrap
ta
Wrap
ta

865
Wrapping
tape
Wrapping
tape
5
CB
A

%
A= X od X Lp x
CB

m2

5
15,53

1,4

3,

Anode Data
1 Material
Natural
potensial (vs
2 CSE)
Anode Driving
3 Voltage
Current
4 Capacity
Consumption
5 Rate
Design
Utilisation
6 Factor
Unit Net
7 Weight

Magnesium
Sp

----En

Volts

Ea

Volts

A-Hr/Kg

Cr

8760/C

Kg/A-yr

Magnesium Magn
Sp
S

-1,5

-1,5

-1

0,65

0,65

0,

1100

1100

11

7,96

7,96

7,

0,8

0,8

7,7

7,7

U
Wa

Kgs

Package
8 Anode Lenght
Package
Anode
9 Diameter
D
1
2
3

Anode
Calculation
BY WEIGHT
Required
Protective
Current
Total Anode
Weight
Minimum
Quantity of
anode

4
5
6 By current
Groundbed
7 anode position
Anode Soil
8 resistance
current output
9 capacity
minimum
quantity of
10 anode

La

cm

Da

cm

75

75

15

15

0,092

0,2

22,94

53

1,025
lp
Wt

Ip = A x i x (1+SF)
Wt= Ip x Y x CR /
U

Amps
kgs

255,09
34

Naw

Naw = Wt/ Wa

pcs

Ra

Ra=px(ln(4xLa/Da)1/(2pixLa)

Ohm

Ia

Ia=Ea/Ra

Amps/pc

Single
Vertical

Single
Vertical

Sin
Ver

6,706

6,706

6,7

0,114

0,114

0,1

9
Nai

Nai=Ip.Ia

pcs

E
Anode
Qty/Grounded
1 Point
Average
Calculated
2 Spacing
Design Anode
3 Spacing

1
Ng

pcs

1
25,4

S
Sp

S= Ngx Lp x Nd

m
m

-25

33,3

49

-33

-5