You are on page 1of 1

Fiber Optic Cable

CentraCore OPGW
CentraCore Optical Ground Wire is available in fiber counts up to 96, and due to its
small size, offers a unique solution to the diameter and weight concerns on many of
todays overloaded towers. A central stainless steel tube houses the optical fibers. The
stainless steel tube is then inserted into an aluminum pipe which provides added crush
protection while increasing the conductivity. The fibers are protected from environmental
conditions (lightning, short circuit, loading) to ensure reliability and longevity.
Features
Fiber counts up to 96
aluminum
clad steel
wire
Very
small
diameter,
low weight
aluminum alloy wire hermetically sealed
Laser-welded,
stainless
steel tubes provide mechanical
aluminum pipe
and
protection for optical fibers
opticalthermal
unit
Central tube provides mechanical and
thermal protection for optical fibers
Excellent crush resistance and high fault
current rating capability
Unique designs have maximum
allowable tension to control fiber strain
Stranded wires selected to optimize
mechanical and electrical properties
of cable

Temperature Range
Operating - 40C to + 85C
Storage

Cable Components

- 50C to + 85C

Installation - 30C to + 85C

aluminum clad steel wire


aluminum alloy wire
aluminum pipe
stainless steel tube
optical fibers

Typical Designs
FIBERS
(max)

OPGW
SIZE

48
48
48
48
48
48
48
48
72
72
72
72
72
72
96
96
96
96
96
96

CC-57/465
CC-29/29/465
CC-54/472
CC-27/27/472
CC-72/504
CC-32/40/504
CC-75/528
CC-38/38/528
CC-54/472
CC-27/27/472
CC-63/507
CC-32/32/507
CC-75/528
CC-38/38/528
CC-65/500
CC-30/36/500
CC-75/528
CC-38/38/528
CC-86/563
CC-34/51/563

FAULT
CURRENT
(kA)sec
43
54
53
63
58
73
77
96
51
61
71
85
75
94
51
64
62
81
86
106

OVERALL
TOTAL CONDUCTOR AREA
aluminum clad DIAMETER
steel wire
in
0.1248
0.1248
0.1339
0.1339
0.1482
0.1482
0.1663
0.1663
0.1318
0.1318
0.1547
0.1547
0.1646
0.1646
0.1393
0.1393
0.1550
0.1550
0.1803
0.1803

mmaluminum alloy
inwire
80.52
0.465
shaped aluminum core
80.52
0.465
86.39helically wrapped
0.472
aluminum tape
86.39
0.472
95.64optical unit0.504
95.64
0.504
107.28
0.528
107.28
0.528
85.01
0.472
85.01
0.472
99.80
0.507
99.80
0.507
106.20
0.528
106.20
0.528
89.86
0.500
89.86
0.500
100.00
0.528
100.00
0.528
116.31
0.563
116.31
0.563

mm
11.80
11.80
12.00
12.00
12.80
12.80
13.40
13.40
12.00
12.00
12.90
12.90
13.40
13.40
12.70
12.70
13.40
13.40
14.30
14.30

WEIGHT
lbs/ft
0.314
0.238
0.317
0.244
0.382
0.296
0.411
0.310
0.316
0.243
0.367
0.282
0.410
0.310
0.381
0.301
0.426
0.325
0.482
0.563

kg/m
0.467
0.354
0.471
0.364
0.568
0.441
0.612
0.462
0.470
0.362
0.546
0.420
0.611
0.461
0.566
0.448
0.634
0.484
0.718
0.582

RBS
lbs
16,626
10,755
16,089
10,523
20,740
14,144
21,845
14,106
16,067
10,501
18,677
12,195
21,831
14,092
19,194
13,104
21,953
14,214
24,879
17,768

kgf

SAG10
CHART #

aluminum
7,541alloy wire
1-1421

4,878
1-1455
7,298
1-1450
stainless
steel tube1-1438
4,773
with optical fibers
9,408
1-1442
6,416
1-1440
9,909
1-1453
6,398
1-1439
7,288
1-1457
4,763
1-1438
8,472
1-1450
5,532
1-1438
9,903
1-1421
6,392
1-1455
8,706
1-1442
5,944
1-1440
9,958
1-1442
6,448
1-917
11,285
1-1425
8,060
1-1460
aluminum clad steel wire

MAX SHIP LENGTH


(per reel type)
Wood (m)
7000
7000
7000
7000
6350
7000
5950
7000
7000
7000
6650
7000
5950
7000
4800
4800
4800
4800
4800
4800

Steel (m)
7000
7000
7000
7000
7000
7000
7000
7000
7000
7000
7000
7000
7000
7000
4800
4800
4800
4800
4800
4800

This information denotes the input data needed for Sag10 (sag and tension calculation) software. WIR files of all these catalog designs can be found on PLS-CADD web page.
NOTE: The designs above are only a sampling of the options available from AFL. Contact customer service for a cable designed to your exact specifications.

www.AFLglobal.com or (800) 235-3423

2002, AFL, all rights reserved. PP-1-00006, Revision 5, 8.17.15