I. INTRODUCTION
Wearable wireless communication system is exciting new
frontier techniques. There are many devices worked in the
proximity or contact of the human body, such as the watch
phone, wearable computing devices, RFID and health care or
monitoring devices, in our life [1][4]. As the devices are used
widely in the human life, the health risks from the
electromagnetic fields are important issue. The study of the
health problem by the electromagnetic wave generated from a
mobile device is in progress in several years [5][6]. To find
out the health problem, the thermal interaction effect of the
human body caused by the electromagnetic wave should be
considered. To investigate the phenomenon, the specific
absorption rate (SAR) which is a defined parameter for
evaluating power absorption in a human tissue is tested. If the
mobile devices have communication services, such as cellular,
PCS and WCDMA, the SAR test must be done by official
certification center and the SAR value must not over the limit
regulated by the international community [7].
Since previous wearable devices are served a low power
consumption services, such as WLAN or RFID, the health
problem from EM waves is not researched widely. But the
wearable devices are offered the communication services such
as WCDMA and it is worn on contact of the body for a long
time, the health problem may be such a important issue in the
future.
The electromagnetic bandgap (EBG) technique is a kind of
handling the electromagnetic properties. Since the EBG has
1433
(a)
Parameter
W
T
L
Value [mm]
17.5
0.6
3
Parameter
G
S
R
Value [mm]
0.4
0.5
2.4
(b)
Fig. 3. Geometry of the proposed PIFA: (a) Top view, (b) side view
TABLE II
SIZE OF THE PROPOSED PIFA STRUCTURE
Parameter
Wa
Ws
We
Wt
Wf
Wu
Value [mm]
15.5
54
17.5
19.9
2.5
22.4
Parameter
La
Ls
Le
Lf
Wr
Value [mm]
10
24
3
7
3
(a)
1434
(b)
(c)
Fig. 4. The porposed wearable communication device: (a) Geometry of the
proposed structure, (b) Simulation set up of the porposed strucuture, (c)
Picture of the proposed the wearable communication test device.
III. RESULTS
Fig. 5 shows a return loss of the proposed PIFA with the
EBG structure. The bandwidth at -10 dB of return loss of the
conventional PIFA and the proposed PIFA with the EBG is
1.95 GHz 1.98 GHz and 1.96 GHz 1.99 GHz, respectively.
All results are satisfied the WCDMA operation band.
(a)
(b)
Fig. 5. Return loss of the proposed antenna
1435
REFERENCES
[1]
[2]
[3]
[4]
[5]
[6]
[7]
TABLE III
SAR VALUES
Type
Conventional
PIFA
The Proposed
PIFA with the
EBG
[8]
[9]
[10]
[11]
IV. CONCLUSIONS
This paper presents a wearable communication device
antenna with the EBG structure for the protection of the
human body from the EM fields at a WCDMA band. The
EBG structure has high impedance surfaces and band stop
characteristics at arbitrary frequency, the characteristic of
electromagnetic wave propagation can change. The proposed
structure is a PIFA based on the slotted square type of the
EBG structure, a frequency generator for the SAR testing and
[12]
[13]
[14]
[15]
1436
C.-H. Wu, K.-L. Wong, Y.-C. Lin and S.-W. Su, Conformal Bluetooth
antenna for watch-type wireless communication device application,
IEEE Antennas Propag. Int. Symp., pp.4156-4159, June 2007.
S.Zhu and R. Langley, Dual-band wearable textile antenna on an EBG
substrate, IEEE Trans. Antennas Propag., Vol. 57, No. 4, Apr. 2009.
Z.Duan, D. Linton, W. Scanlon and G. Conway, Improving wearable
slot antenna performance with EBG structures, 2008 Loughborough
Antenna & Propag. Conf., pp.173-176, Mar. 2008.
L. Yang, L.J. Martin, D.Staiculescu, C. P. Wong and M. M. Tentzeris,
Conformal magnetic composite RFID for wearable RF and biomonitoring applications, IEEE Trans. Microw. Theory Tech., Vol. 56,
No. 12, Dec. 2008.
IEEE standard for Safety Levels with Respect to Human Exposure to
Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz, 1992,
IEEE C95.1-1991, Institute of Electrical and Electronics Engineers, Inc.
New York.
S.I. Kwak, D.U. Sim, J. H. Kwon and H.D. Choi, Experimental tests
of SAR reduction on mobile using EBG structures, Electronics Lett.,
Vol. 44, No.9, pp. 568-570, Apr. 2008.
Guidelines on limits of exposure to radio frequency electromagnetic
fields in the frequency range from 100 kHz to 300 GHz, Health Phys.,
vol. 54, no.1, pp. 115-123, 1988, International Non-Ionizing Radiation
Committee of the International Radiation protection Association.
D. Sivenpiper, L. Zhang, R. F. Broas, N. G. Alexopoulos and E.
Yablonovitch, High-impedance electromagnetic surface with a
forbidden frequency band. IEEE Trans Microw. Theory Tech.,Vol. 47,
No. 11, pp.2059-2074, Nov. 1999.
B. Kim and D.-W.
Kim, "Bandwidth Enhancement for SSN
Suppression Using a Spiral-Shaped Power Island and a Modified EBG
Structure for a /4 Open Stub," ETRI Journal, Vol.31, No.2, pp. 201208, Apr. 2009.
J. H. Kwon, S.I. Kwak, D.-U. Sim and J.G. Yook, Partial EBG
structure with decap for ultra-wideband suppression of simultaneous
switching noise in a high speed system, ETRI Journal, Vol. 32, No. 6,
pp. 209-213, Apr. 2010.
J.-M. Baracco, L. S.-Drioli and P. de Maagt, AMC low profile
wideband reference antenna for GPS and GALILEO systems, IEEE
Trans. Antennas Propag., Vol. 56, No. 8, Aug. 2008.
P. de Maagt, R. Gonzalo, Y. C. Vardaxoglou and J.M. Baracco,
Electromagnetic Bandgap Antennas and Components for Microwave
and (Sub)Millimeter Wave Applications, IEEE Trans. Antennas
Propag., Vol. 51, No. 10, Oct. 2003.
S. I. Kwak, D.U. Sim, J.H. Kwon and J.H. Yun, SAR reduction of
PIFA with EBG structures for mobile applications, IEIEC Trans.
Commun., Vol.E92-B, No.11, pp. 3550-3553, Nov. 2009.
F. Yang and Y. Ramat-Samii, Reflection phase characterization of the
EBG ground plane for low profile wire antenna applications, IEEE
Trans. Antennas Propag., Vol. 51, No. 10, Oct 2003.
CST Microwave Studio V2009, www.cst.com.