You are on page 1of 3

Technical Datasheet of LT Motor

Project Name
Equipment Name
SL No.

Bar Mill, Phase -1b, JSPL, Angul


15T Below Magnet EOT Crane

Description

Bidder To Fill Up

General

Make

kW Rating

Application

Tag No

NA

Pump/Load Model

NA

Qty. (Nos)

Reference Standard

Location of Motor (Indoor/Outdoor)

Canopy ( For Outdoor Installation)

Technical

10

Type

SCIM

11

Energy Efficiency

94%

12

Mounting

B3

13

Enclosure

TEFC Squirrel Cage

14

Protection

IP 55

15

Duty

16

Cooling

17

Ambient Temp

50 Deg C

18

Insulation Class

19

Temp. Rise Limitation

F
F

20

Method Of Starting

21

Direction Of Rotation

22

Voltage W ith Variation

415 10%

23

Frequency W ith Variation

50 5%

24

Phase

25

Combined Variation

26

Unbalance In Supply System

27

Min Voltage for Start & Run

28

Motor Connection
(Motor with frame size 90 shall be connected in STAR and
of frame sizes more than 90 shall be connected in DELTA,
for delta connected motors 6 leads shall be brought out)

29

Output At 40 Deg C

30

Output At 50 Deg C

31

No. Of Poles

32

Rated Speed Rpm

33

Frame Size

34

Efficiency at 100%, 75%, 50%

35

PF at 100% , 75% , 50%

36

No Load Power Factor

37

Rated Torque (Kgm)

38

Starting Current (X FLA) At 100% Vr

39

Starting Current (X FLA) At 110% Vr

40

Starting Current (X FLA) At 80% Vr

Siemens Ltd

90 KW
Gantry Crane
2

IEC60034-1
Suitable for indoor application
NA

S4
IC411

VFD
Bidirectional

3
10% absolute
NA

85% of Rated Voltage at Terminal


Delta , 6 leads

NA
90 KW

8
737
315M
94%/94%/93%
081/0.78/0.61
NA
119 kgfm
902 A
NA
NA

Page 1 of 3

SL No.

Description

41

Starting Torque At 100% Vr(X FLT)

42

Starting Torque At 80% Vr(X FLT)

43

Pull Up Torque (X FLT)

44

Maximum Torque (X FLT)

45

Full Load Current (Amps)

46

No Load Current - Approx.(A)

47

Rotor Gd Sq. Value (Kgm2)

48

Load Gd Sq. Values (Kgm2)

49

Thermal Withstand Time (Hot / Cold)

50

Thermal Withstand Time (Hot / Cold) At 80% & 110% Vr

51

Motor Hot & Cold Thermal Withstand Constant


Starting Time At 100% & 80% Rated Voltage (Without

52

Bidder To Fill Up

226.1kgfm
NA
249.9 kgfm
249.9 kgfm
164A
NA
12 kgfm2
NA
9S/27S
NA
9S/27S
NA

53

Load)
Starting Time At 100% & 80% Rated Voltage (With Load)

54

Permissible Over Load Capacity

60% overload for 15 Sec

55

Whether Motor Is Tropicalised & Fungicidal Treated

56

Maximum Over Speed Permissible

Tropicalised
120% over speed for 2 minutes for Inverter Duty
Grade, as per
IS-325

57

Bearing Type

C3

58

Bearings (DE/NDE)

6319C3/6319 Insulated

59

Bearing Make

SKF/FAG

60

Details RTD & BTD

RTD-3XPT100 Simplex

61

Greasing point of bearing

Grease Nipple

62

Details Of Space Heater (No. & Watt)

220V/98W

63

No. Of Start Per Hour

150 Start Per Hour

64

Maximum Permissible Cable Size For Termination

2R 3 and Half Core 240 mm2

65

Safe Stall Time (Hot/Cold) at 100% voltage

NA

66

Paint Shade

RAL 7037

67

Motor Weight (Kg) - Approx.

900 KG

68

Terminal Box Design Type

TOP

69

Terminal Box Fault Level (For PSTB) Only

45 KA for 0.25 Sec

70

Location of Terminal Box from viewed from DE

TOP

71

Main Terminal Box

TOP

72

Space heater terminal box (where applicable)

TOP

73

Thermister terminal box (where applicable)

74

Method Of Coupling

Direct

75

General Assly. Drawing

attached

76

Terminal Box Assly. Drawings

Yes

77

Earthing stud

2 nos on motor body


- 1 no inside terminal box

78

Motor Space Heater

Yes

79

Motor Constructional features

Stator Frame

315M

Motor Body

CI

Casing Feet

Integral

Body design

CI

Protection of Motor,terminal box and bearing

NR

Shaft

Steel With Al Diec Cast

Balancing

Half Key Balancing

Stator core

Laminated Sheet

NA

SL No.

Description

Bidder To Fill Up

NOTE:

Windings insulating material shall be Dual Coated Winding wire, impregnated with VPI process

All Above Performance Figures Are Subject To IS Tolerance

Noise Level Will Be Limited To As Per IS: 12065

Vibration Level Will Be Limited To IS: 12075

Balancing will be As per IS/ ISO -1940

Terminal Box Rotable In Steps Of 90 Deg Through 360 Deg

Motor shall be greased for life time - Motor shall be regreased at periodic intervals
Drawing to be submitted with Motor Datasheet

Motor and Terminal Box GA


Characteristic Curve

Load Performance Curve

Load Current & Speed Vs Time Curve

Torque & Current /Speed Curve

Thermal withstand time curve

Page 3 of 3

You might also like