PILOT OPERATED SOLENOID VALVE CEME 2/2 ESM 87 NO

MAIN CHARACTERISTICS
The
solenoid valve is a 2/2 piloted valve dedicated to
the shut off of clean and non-aggressive fluids. The operation
way is normally opened. The standard construction includes
quality brass body and cover, internal parts in stainless steel
and diaphragm is NBR. This solenoid valve is also available
with several diaphragm materials and various coil voltages.
The
W version 1/2 ", 3/4 " and 1 " have the French
homologation ACS for the drinking water.

AVAILABLE MODELS
ESM87 : G 3/8" to G 3"
ESM87W : G 1/2" to G 1"
Diaphragm : NBR, EPDM et FPM.
Voltages : See on page 3.
BSP Screwed end connections.

LIMITS OF USE
Electric protection

IP 65

Max allowed fluid pressure : PS


Max allowed fluid temperature : TS

Room temperature

0 - 10 bar
NBR

EPDM

FPM

+80C

+110C

+150 C

IP
65

ISO
9001

-10C / +80C

* In direct current, over 40C, the maximum differential


pressure can be reduced.

P (Bar) - NBR

P (Bar) - EPDM

P (Bar) - FPM

12

Pressure (bar)

10
8
6
4
2
0
-10 0

10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160


Temperature (C)

Modifications reserved
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER FRANCE
Tl : +33 4 74 94 90 70 Fax : +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr

Nbr. pages
Ref.
Rev.
Date

1/4
FT8700 ENG
0
03/14

PILOT OPERATED SOLENOID VALVE CEME 2/2 ESM 87 NO


REGULATIONS AND STANDARDS OF CONSTRUCTION
Item

Standard

Item

Pressure Equipement Directive


CE 97/23

3/8 to 1 : A3 3 excluded

Low voltage directive CE 73/23

category I

1"1/4 to 3 : category I

Standard

Brass materials

EN 1503-4

BSP thread

ISO 228
1/2" : 10 ACC LY 343

Connector

DIN 43650

Drinking water (ESM87 W)

3/4" : 10 ACC LY 343


1" : 10 ACC LY 343

PRESSURE LOSS DIAGRAM (BAR)


12-20-25-32-39-51-65-75

Flowrate (m3/h)

DIMENSIONS (mm) AND WEIGHT (kg)


DN
G 3/8
G 1/2"
G 3/4"
G 1
G 1 1/4
G 1 1/2
G 2
G 2 1/2
G 3

A
61
61
87
100
131
146
174
245
250

B
95
95
107
113
128
135
151
186
196

C
48
48
69
80
112
128
146
184
184

D
83
83
91
93
101
105
114
140
145

Weight (Kg)
0,6
0,6
1
1,2
2,8
3,5
4,8
11,4
12

Modifications reserved
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER FRANCE
Tl : +33 4 74 94 90 70 Fax : +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr

Nbr. pages
Ref.
Rev.
Date

2/4
FT8700 ENG
0
03/14

PILOT OPERATED SOLENOID VALVE CEME 2/2 ESM 87 NO


HYDRAULIC CHARACTERISTICS
DN

Kv
(m3/h)
1,86
2,1
5,7
9,6
22
27
35
63
83

Port (mm)

G 3/8
G 1/2"
G 3/4"
G 1
G 1 1/4
G 1 1/2
G 2
G 2 1/2
G 3

10
12
20
25
32
39
51
65
75

Min diff.
pressure (bar)
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3

Max diff. pressure


(bar)
10
10
10
10
10
10
10
10
10

Coil

Operating time

20-60 ms

B6
50-80 ms

ELECTRIC CARACTERISTICS
Coil classified H. Duty 100%. Connecting by connector T30.
Coil
B6

Current
AC Coil
DC Coil

Available voltages (V)


12
12

24
24

48
48

110
110

230

Frequency
400

50 Hz

60 Hz

Power consumption
Holding

Rush

15 VA
16 W

25 VA

CONSTRUCTION
N
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Item

Material

Lock nut
Coil
Tube guide
Plunger
Spring
Tube guide
Shutter
Spring
Support
Seal
Spring
Screw

Zincated steel
PBT + 30% G.F.
Stainless steel AISI 430
Stainless steel AISI 430
Stainless steel AISI 430
Stainless steel AISI 430
Stainless steel AISI 303
Steel
Stainless steel
NBR
Steel
Stainless steel

Cover

Brass CW 617 N
Steel
NBR/EPDM/EPDM KTW/FPM
Brass
Brass CW 617 N

Spring
Diaphragm
Bush
Body

Modifications reserved
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER FRANCE
Tl : +33 4 74 94 90 70 Fax : +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr

Nbr. pages
Ref.
Rev.
Date

3/4
FT8700 ENG
0
03/14

PILOT OPERATED SOLENOID VALVE CEME 2/2 ESM 87 NO


USE ON DRINKING WATER
The W version of the
in diameters 1/2 ", 3/4 " and 1 " can be used on the networks of drinking water.
It has the French homologation ACS.

MOUNTING
Installation in every position except horizontal pipe with coil towards the bottom.
Respect the sense of flow indicated by the arrow marked on the body.
For an use on liquids, the installation of a strainer for upstream protection is recommended.
Conform to the assembly instructions supplied with the solenoid valve.

SPARE PARTS
B 6 coil type (Number A)
Voltage
Code
Voltage
Code

230V 50Hz
980310
230V 60Hz
980320

24V 50Hz
980311
24V 60Hz
980321

48V 50Hz
980313
48V cc
980317

Connector

110V 50Hz
980314
110V cc
980318

12V cc
980315
12V 50 Hz
980312

24V cc
980316
380V 50Hz
980319

T30
980696

Diaphragm (Number 15)


DN

3/8

NBR
EPDM
FPM
EPDM W

1/2"

980604
980614
980624
980661

3/4"

1 1/4

1 1/2

2 1/2

980632
980642
980652
980662

980605
980615
980625
980663

980634
980644
980654

980606
980616
980626

980607
980617
980627

980608

CEME TRANSLATIONS REFERENCES


Diameter

3/8

1/2

3/4

CEME
SECTORIEL

8713

8714

8715

1 1/4

8716
8717
See WEB catalog

1 1/2

2 1/2

8718

8719

8720

8721

Modifications reserved
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER FRANCE
Tl : +33 4 74 94 90 70 Fax : +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr

Nbr. pages
Ref.
Rev.
Date

4/4
FT8700 ENG
0
03/14

You might also like