BEAM to COLUMN SHEAR CONNECTION HI300-8-10*200:

PL15 / 4M24 bolts

h := 300 mm

Sectional Properties:

b := 200 mm

W = 658453
N := 120

Loading:

V := 18

kN

s := 8

As = 6240

mm3

kN

Aw = 2240

mm2

Beam 27

tf := 10 mm

mm

Comb 101 C01

Connection Properties:
tp := 15

Plate Thickness:

mm

d b := 24 mm

Bolt Diameter:

Number of bolts:

n b := 4

k := 1

Double shear factor:

Bolt Threaded
Area:

Bolt
Area:
d b

Ab :=

-->

Ab = 452.4

mm2

Abn = 353

Sectional Capacities according to SNIP II-23-81


Ryn := 335 MPa
Run := 480 MPa
m := 1.1

According to table 2

c := 1.0

According to table 6

u := 1.3

Ryn

Axial Capacity:

Ncap := max

Shear Capacity:

Vcap :=

Run

3
c As 10 --> Ncap = 2095

0.58 Ryn
3

c Aw 10
m

Cases:
1) External Loading
2) 10 % Axial Tension Capacity + 60 % Shear Capacity
*Bolt Shear and Tension Check:
Rbs := 320

MPa (according to Table 58)

Rbt := 400

MPa (according to Table 58)

b := 0.75

kN

m m u

(according to Table 35)

--> Vcap = 396

kN

mm2

mm2

Nb := Rbs b Ab 10
Nb := Rbt Abn 10

-->

-->

Nb = 109

kN >

Nb = 141

kN >

max( V , 0.6 Vcap)


nb

= 59

max( N , 0.1 Ncap)


nb

= 52

kN

OK

kN

OK

*Plate Bearing Check:


Rbp := 670

MPa (according to Table


59)
3
--> Nb = 181
Nb := Rbp b d b tp 10

max( V , 0.6 Vcap)

kN >

nb

= 59

kN

OK

*Plate Bending Check:


a := 150 mm -->

2a = 300

mm

b := 100 mm

2a
a

= 1.5

-->

:= 0.0817

max( N , 0.1 Ncap) 10

b
q :=

M := q b

2a b

-->

q = 3.491

N/mm2

2
2

Ryn tp
M cappl :=
c 6
m

M cappl = 11420 Nmm/mm

>

M = 2852

Nmm/mm

OK