Professional Documents
Culture Documents
Product Catalog
57th Edition
Arizona
Tolleson, Arizona
Northern California
Livermore, California
Southern California
Corona, California
Texas Warehouse
Humble, Texas
Florida
Largo, Florida
Canada
Thornhill, ON Canada
MONTGOMERY, MN
THORNHILL, ON, CA
LUMBERTON, NJ
LIVERMORE, CA
CORONA, CA
TOLLESON, AZ
HUMBLE, TX
LARGO, FL
USP Structural Connectors Corporate Office: 14305 Southcross Drive-Suite 200, Burnsville, Minnesota 55306
(952) 898-8772 (800) 328-5934 www.USPconnectors.com
Follow us on:
www.facebook.com/uspconnectors
www.twitter.com/uspconnectors
2013 MiTek USA, Inc. USP 2240-131
57th Edition
Table of Contents
Corrosion Information . . . . . . . . . . . . 7-8
Design Notes. . . . . . . . . . . . . . . . . . 11
Installation Notes. . . . . . . . . . . . . . . 12
Product Information. . . . . . . . . . . . . . . . 9
Product Notes. . . . . . . . . . . . . . . . . 10
Reference Number Index . . . . . . . . . 6
USP Index. . . . . . . . . . . . . . . . . . . . 4-5
Fasteners
Angles. . . . . . . . . . . . . . . . . . . . . . 201
Bolt Down . . . . . . . . . . . . . . . . . . . 189
Bridging. . . . . . . . . . . . . . . . . . 183-184
Closet Rods. . . . . . . . . . . . . . . . . . 202
Concealed Stringer Hanger. . . . . . 194
Corner Tie. . . . . . . . . . . . . . . . . . . 204
Deck Clip. . . . . . . . . . . . . . . . . . . . 185
Deck Ties . . . . . . . . . . . . . . . . . . . 193
Deck Tie Back. . . . . . . . . . . . . . . . 192
Drywall Clip. . . . . . . . . . . . . . . . . . 197
Fence Brackets. . . . . . . . . . . . . . . 190
Fence Post Connectors. . . . . . . . . 188
Fence Rail Hanger . . . . . . . . . . . . 196
Hardy Frame. . . . . . . . . . . . . . 206-209
Insulation Supports. . . . . . . . . . . . 203
Mending Plates. . . . . . . . . . . . . . . 198
Nail Plates. . . . . . . . . . . . . . . . . . . 198
Pipe Rail Ties . . . . . . . . . . . . . . . . 191
Plastic Post Caps . . . . . . . . . . . . . 204
Plywood Clips. . . . . . . . . . . . . . . . 197
Protection Plates. . . . . . . . . . . . . . 186
Ridge Rafter . . . . . . . . . . . . . . . . . 199
Shelf Brackets. . . . . . . . . . . . . . . . 203
Stair Angles. . . . . . . . . . . . . . . . . . 195
Step Flashing . . . . . . . . . . . . . . . . 196
Stud Shoes. . . . . . . . . . . . . . . . . . 189
Tough Tie Products. . . . . . . . . 199-200
Wall Bracing . . . . . . . . . . . . . . . . . 187
Wall Ties. . . . . . . . . . . . . . . . . . . . 201
Manufactured Housing. . . . . . . 205
Lateral Systems . . . . . . . . . . 206-209
Specialty Options. . . . . . . . . . . . 210-213
Corrosion Resistant Products
. .
. . . . . . . . . . . . . . . . . . . . . . . . 214-215
Plated Truss
Section Overview . . . . . . . . . 163-164
Alternate Installations . . . . . . . . . . 182
Blocking Supports. . . . . . . . . . . . . 179
Drag Strut Connectors. . . . . . . . . . 181
Girder Truss Hangers. . . . . . . 174-176
Hip/Jack Connectors. . . . . . . . 172-173
Roof Truss Ties. . . . . . . . . . . . . . . 179
Skewed Truss Hangers. . . . . . 170-171
WARRANTY
MiTek USA, Inc. (MiTek) warrants its USP catalog Products to be free from material
defects in manufacture and design, and further warrants that they will perform within the
design limitations of its published building code approvals for the applications described,
when properly installed and maintained. These warranties do not cover Product
deterioration due to environmental conditions, Products that have be modified or damaged,
improperly installed or used outside of published design limitations or for other applications. In the event any Product is shown to not conform to these warranties, USPs sole
obligation, and Customers sole and exclusive remedy, shall be, at USPs option, to replace
the non-conforming product or refund the full purchase price paid by Customer to USP
therefor. USP MAKES NO OTHER PRODUCT WARRANTIES, EXPRESS OR IMPLIED,
1-800-328-5934 www.USPconnectors.com
Miscellaneous
Hangers
Section Overview . . . . . . . . . . . . . 13
Bearing Plates. . . . . . . . . . . . . . . . . 20
Nails. . . . . . . . . . . . . . . . . . . . . . 14-15
Wood Screws . . . . . . . . . . . . . . . 16-19
LumberLok Screws. . . . . . . . . . . . . . 20
HARDY
FRAME
USP Index
GEL Epoxy (CIA-GEL Series) . . . . .23
GHF Glulam Face Mount Hangers .146
GT Girder Truss Hangers . . . . .174-175
GTD Girder Truss Hangers . . .174-175
* GTQ/GTQM Girder Truss Hangers .176
GTS Girder Truss Hangers . . . .174-175
GTWS Girder Truss Hangers . . . . .175
Hanger Selector Guide . . . . . . . . . .87
HBPS Bearing Plates . . . . . . . . . . . . 20
HC520 Hurricane/Seismic Anchor160,162
* HCPRS Rafter Ties . . . . . . . . .160, 162
HD Face Mount Hangers . . . . . . . . . . . .
. . . . . . . . . . . . . . . .90-96, 118, 122-123
HDO Top Mount Hangers . . .97, 99-101
HDQIF Inverted Flange Hangers . . . . . .
. . . . . . . . . . . . . . . .90, 92-96, 119, 123
* HFX Hardy Frame Panels & Brace
Frames . . . . . . . . . . . . . . . . . . . . .206
HGA Hurricane Gusset Angles . . . .158
* HGU Girder Hangers . . . . . . . . . . . 145
HH Header Hangers . . . . . . . . . . . . .75
HHC Hip/Hip Connectors . . . . . . . . .173
HHCP2 Hurricane/Seismic Anchor . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .160,162
HJC Hip/Jack Connectors . . . . . . . .173
HJHC Hip/Jack Connectors . . . . . . .173
HL Light Gauge Purlin Hangers . .98-99
HLBH Beam Hangers . . . . . . . . . . . . . .
. . . . . . . . . . . . .126, 132-136, 138-142
* HPAHD Foundation Straps . . . . . .48-49
* HRS Strap Ties . . . . . . . . . . . . . .77, 79
HTC4 Heavy Truss Clip . . . . . . . . . .179
HTHJ Hip/Jack Connectors . . . . . . 173
* HTP Strap Ties . . . . . . . . . . . . . . .77-78
HTT Tension Ties . . . . . . . . . . . . . . . .45
HTW Twist Straps . . . . . . . . . . . . .81-82
HTWM Twist Straps . . . . . . . . . . . . . .85
HUGT Girder Tiedowns . . . . . . . . . 156
HUS Slant Nail Hangers . . . . . . . . . . . .
. . . . . . . . . . . . .89, 91-95, 119, 123,167
HWUH
Top Flange Hangers . . 106-107
*
ICPL Protection Plates . . . . . . . . . .186
IS Insulation Supports . . . . . . . . . . .203
JA Framing Angles . . . . . . . . . . . .69-70
* JDS Purlin Hangers . . . . . . . . . . . . .112
* JH Multi-Purpose Joist Hangers . . .102
JL Standard Joist Hangers . . . . .88, 91
JLIF Inverted Flange Hangers . .88, 91
* JN Power Nail Hangers . . . . . . . . . .205
* JN(E) Power Nail Hangers . . . . . . .205
JNP Mending Plates . . . . . . . . . . . .198
JP Adjustable Support Post . . . . . . . .37
JPF Purlin Hangers . . . . . . . . . . . . .110
JUS Slant Nail Joist Hangers .89, 91-95
KB Hanger . . . . . . . . . . . . .97, 100-101
KCBQ Column Bases . . . . . . . . . . . .56
* New Products
1-800-328-5934 www.USPconnectors.com
USP Index
MP_F Multi-Lateral Plate Ties . . .66-67
MPH Masonry Hangers . .108, 126-141
* MRT7 Power Nail Hangers . . . . . . .205
MSH Strap Hangers . . . . . . . . .168-169
MSHL/R Skewed Truss Hangers . . .170
MSSH Skewed Hanger . . . . . . .170-171
MSTA Strap Ties . . . . . . . . . . . . . .77-78
MSTAM Masonry Strap Tie . . . . . . . .84
MSTC Strap Ties . . . . . . . . . . . . .77-79
MSTCB Pre-Bent Strap . . . . . . . . . . .80
MSTCM Masonry Strap Tie . . . . . . . .84
* MTHF Power Nail Hangers . . . . . . .205
MTW Twist Straps . . . . . . . . . . . . .81-82
MUGT15 Girder Tiedown . . . . . . . . .155
MUS Slant Nail Joist Hangers . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .89, 91, 167
N Bridging . . . . . . . . . . . . . . . . . . . .183
NA Nails . . . . . . . . . . . . . . . . . . . .14-15
NOP Moisture Barrier Plates . . . . . .152
NP Nail Plates . . . . . . . . . . . . . . . . .198
NSR Nail Stake . . . . . . . . . . . . . . . . .29
O Bridging . . . . . . . . . . . . . . . . . . . .183
Ornamental series . . . . . . . . . . . . . .74
PA Post Anchors . . . . . . . . . . . . . . . .52
PA Purlin Anchors . . . . . . . . . . . . . . .50
PA(E) Post Anchors . . . . . . . . . . . . . .52
* PAHD Foundation Straps . . . . . . .48-49
PAI Purlin Anchors . . . . . . . . . . . . . . .50
PAU Post Anchors . . . . . . . . . . . . . . .52
PB Post Caps . . . . . . . . . . . . . . . . . .58
PBC Post Beam Corner . . . . . . . . . .59
PBES Post Caps . . . . . . . . . . . . . . . .58
PBS Post Caps . . . . . . . . . . . . . . . . .58
PCM Post Caps . . . . . . . . . . . . . . . . .57
PCP Plastic Post Caps . . . . . . . . . .204
PHD Predeflected Holdowns . . . . . . .41
PHDA Predeflected Holdowns . . . . . .41
PHM Top Flange Hangers . . . . . . . . . . .
. . . . . . . . . . . . . . . . .126-131, 133-141
PHXU Top Flange Hangers . . . . . . . . . .
. . . . . . . . . .126-129, 132-136, 138-142
PL4 Protection Plate . . . . . . . . . . . .186
* Power-Stud HD5 . . . . . . . . . . . . . .26
* PRT Pipe Rail Ties . . . . . . . . . . . . .191
PWFS24 Wood Foundation Strap . . .83
RBC Roof Boundary Clip . . . . . . . . . .68
RC Plywood Clips . . . . . . . . . . . . . .197
RCD Rod Chair . . . . . . . . . . . . . . . . .28
RCT Rod Chair . . . . . . . . . . . . . . . . .28
RFUS Uplift Girder Tie . . . . . . . . . . .153
RKS200 Kwik Strip Ties . . . . . . . . . . .30
1-800-328-5934 www.USPconnectors.com
* New Products
1-800-328-5934 www.USPconnectors.com
Corrosion Information
Hot-Dip Galvanized
Use
Example
Environment
Applications
Continuously protected from
General framing,
weather or other sources of
interior construction
moisture
Protected from weather, but may be Sill plates
subject to sources of moisture
Preservatives and
Minimum Coating
Retentions6,7
Requirements1,2,3,4
Untreated
G90
SBX-DOT, Organic
ACQ-D (0.25), CA-B (0.10),
CA-C (0.06), MCQ (0.25),
CA-C (0.05)
Exterior construction, Exposed to all weather cycles, not Exposed exterior beams ACQ-D (0.25), MCQ (0.25),
exposed
to
prolonged
wetting
CA-B
(0.10), CA-C (0.06),
or columns in an open,
Above ground,
CA-C (0.05), Organic
covered structure
Rapid water runoff
G90
Triple Zinc (G-185)8,9
UC3B
UC4A
Exterior construction,
Ground contact,
General use
Exterior construction,
Ground contact,
Critical structural
Deck posts
UC3A
UC4B
Notes:
Gold Coat
Stainless Steel
1. G90 and G185 refer to galvanization requirements for ASTM A653 material.
2. Connectors galvanized to ASTM A123 may be used in place of either G90 or G185 coatings.
3. Other coating may be suitable for a given environment if the conditions are known and predictable.
For Gold Coat connectors use Gold Coat fasteners, and for
4. For
G90 or G185 connectors use fasteners galvanized per ASTM A153. For Gold Coat connectors use Gold Coat fasteners, and for stainless steel
stainless steel connectors use stainless steel fasteners.
connectors use stainless steel fasteners.
5
5. If the environment has the potential to contain elements which may make it more corrosive, the use of stainless steel is recommended.
6. MCQ is a micronized copper treatment such as Micro Pro by Osmose. CA-C is a dispersed copper treatment manufactured by Arch Treatment Technologies.
Organic preservatives include L3 from Arch Treatment Technologies and EcoLife II from Viance, LLC.
7. For wood treatments not shown contact USP or the wood preservative manufacturer for recommended coatings.
8. Testing
by USPwith
hasMCQ
found
that intreated
interior
G90 connectors
or CA-C
woodapplications
is appropriate.where the treated wood will remain relatively dry during its service life the use of G90 connectors with
MCQ or CA-C treated wood is appropriate.
1-800-328-5934 www.USPconnectors.com
USP2240-131
Corrosion Information
USP recommendation
and standards
met with Triple
Zinc coating.
Bin Card
Part number is
referenced with
a TZ at the
end for Triple
Zinc products.
Product Label
Part number is referenced
with a TZ at the end for
Triple Zinc products.
, FL821.42
Carton Label
Part number is
referenced with a TZ
at the end for Triple
Zinc products.
1-800-328-5934 www.USPconnectors.com
Product Information
U.S. Standard Steel gauge
Equivalents in Nominal Dimensions
Approximate Dimensions
Gauge
3
7
10
11
12
14
16
18
20
22
Inches
1/4
3/16
9/64
1/8
7/64
5/64
1/16
3/64
1/32
1/32
Decimals (inches)
Millimeters
6.0
4.5
3.4
3.0
2.7
2.0
1.5
1.2
1.0
0.8
Uncoated Steel
0.238
0.171
0.129
0.114
0.099
0.070
0.055
0.044
0.033
0.029
*Actual steel dimensions will vary from nominal dimensions according to industry tolerances.
Lbs
Nom
Dim
2x4
2x6
2x8
2 x 10
kN
DF
4
100%
1476
1910
2158
2524
SPF
3
115%
1697
2197
2482
2903
DF
3
100%
1165
1508
1703
1992
115%
1340
1734
1958
2291
S-P-F
3
100%
6.57
8.50
9.60
11.23
115%
7.55
9.77
11.04
12.91
100%
5.18
6.71
7.58
8.86
115%
5.96
7.71
8.71
10.19
1) Applies to nominally dimensioned joist as listed in dry service conditions and temperatures less than 38 C.
2) Loads apply to: DF-L: Douglas Fir-Larch (G=0.49), fv=1.9 Mpa; S-P-F: Spruce-Pine-Fir (G=0.42), fv=1.5 Mpa
3) 115% loads are increased for short term loading in accordance with the code. Kd = 1.15.
4) Assumes system factor Kh = 1.00.
Roof Pitch
If common Rafter
Roof Pitch is . . .
Rise / Run
(inches)
Slope
(degrees)
1/12
2/12
3/12
4/12
5/12
6/12
7/12
8/12
9/12
10/12
11/12
12/12
5
10
14
18
23
27
30
34
37
40
42
45
Then Hip/Valley
Slope
Rafter Roof Pitch
Conversion
Table
becomes . . .
Rise / Run
(inches)
Slope
(degrees)
Rise / Run
(inches)
Slope
(degrees)
1/17
2/17
3/17
4/17
5/17
6/17
7/17
8/17
9/17
10/17
11/17
12/17
3
7
10
13
16
19
22
25
28
30
33
35
0/12
1/12
2/12
3/12
4/12
5/12
6/12
7/12
8/12
9/12
10/12
11/12
12/12
Flat
5
10
14
18
23
27
30
34
37
40
42
45
1) Use this conversion table only for hip/valley rafters that are
skewed 45 right or left. All other skews or dual pitch roofs
will cause the slope to change from that listed above.
1 5/8
37
1 5/8
3/16
(9)
Uplift
Per
F2
pen
F1
dic
ula
l
era
Lat
Ou
t
F1
F2 or F3
Download
1-800-328-5934 www.USPconnectors.com
22
Product Notes
1) This catalogue reflects the most current information
regarding USP product line. However, product revisions and
new product additions occur on an ongoing basis. USP
Structural Connectors reserves the right to change
specifications, designs, and models at any time without
notice and liability for such changes. This catalogue may not
be reproduced in whole or in part without the prior written
approval of USP Structural Connectors.
design load
information
information
valid until
9) Load values for 8d, 10d, 16d, and 20d designations in the
fastener schedules throughout this catalogue refer to common wire nails unless noted otherwise. Nails shall conform
to a recognized national standard, such as ASTM F1667, as
prescribed by the model building codes.
10) Diamond holes are for optional nailing.
10
1-800-328-5934 www.USPconnectors.com
Design Notes
1) Factored resistances for more than one direction for a
single connection cannot be added together. A design load
which can be divided into components in the directions given
must be evaluated as follows:
Factored uplift / Factored uplift resistance + Factored
parallel to plate / Factored parallel to plate resistance +
Factored perpendicular to plate / Factored perpendicular
to plate <= 1.0
2) Connector ratings may exceed the tensile strength or other
aspects of the wood members involved in the connection.
A qualified designer should verify wood member capacities
when specifying connectors.
3) Verify that the size of the supporting member can
accommodate the connectors specified fasteners.
4) Some illustrations in this catalogue may not reflect
additional mechanical reinforcements which may be required
to reduce cross grain tension or wood member bending under
loading. The design professional is responsible for
determining if additional mechanical reinforcement is
required.
5) USP recommends the hanger height be a minimum of 60%
of the joist height for stability.
Limit States Design
The factored resistance values presented in this catalogue
are for Limit States Design (LSD) in accordance with the
2010 National Building Code of Canada (NBCC). The values
have been developed by either testing to CSA O86-09, or soft
converted from working stress design. These procedures are
summarized as follows:
(a) Testing to CSA O86
Products that have been evaluated to the CSA Standard
are listed under the Codes heading in each product series
section if applicable. Visit USPs Web Site,
<http://www.USPconnectors.com/>, or specific code
agencies web site for current listing. Code evaluation
numbers listed in this catalogue may not apply to all stock
numbers or product series listed.
Material
USP selects steel for its various products in accordance with
application needs and steel properties, including tensile
strength, ductility, corrosion resistance, gauge, and
weldability. See specific code evaluations or consult USP for
1-800-328-5934 www.USPconnectors.com
USP2240-131
11
Installation Notes
1) Use proper safety equipment during connector
installations. Always wear gloves when handling connectors.
12
1-800-328-5934 www.USPconnectors.com
Fasteners
Nails. . . . . . . . . . . . . . . . . . . . . . Pages 14-15
N & NA Series
USP structural nails and common nail design information.
Fasteners
NA
WS Series
USP self-drilling wood screws.
WS
LL
BP/LBP
1-800-328-5934 www.USPconnectors.com
HBPS/LBPS
USP2240-131
13
Fasteners
Wire
Gauge
6d
8d
10d
16d Sinker
12d
16d
20d
11-1/2
10-1/4
9
9
9
8
6
Minimum
Shank
Penetration
Diameter for Full Load
(inches)
(inches)
0.113
0.131
0.148
0.148
0.148
0.162
0.192
Minimum
Penetration for
2
Reduced Load
(inches)
1.13
1.31
1.48
1.48
1.48
1.62
1.92
0.68
0.79
0.89
0.89
0.89
0.97
1.15
HDG
GC
SS
2+)*4
USP
7
Stock No.
NA11
NA9D
N10C
NA16D
N16C
NA20D
N8-GC
N10-GC
N10C-GC
N16C-GC
SSNA8D
SSNA10D
SSN8C
SSN10C
SSN16C
8d Common
10d Common
16d Sinker
NA16D-RS
16d Common
20d Common
;0..0/!1+2#;0..0/!1+2# ;0..0/!1+2#
;0..0/!1+2#-
Ref. No.
N8
N10
10DHDG
N16, N16EG
16DHDG
-- --- --- --- --- -SSN8
SSN10
SS8D
SS10D
SS16D
-- --- --- --- --- --- --- --- --- --- --
Description (in)
8d (0.131) x 1-1/2
10d (0.148) x 1-1/2
10d (0.148) x 3
16d (0.162) x 2-1/2
16d (0.162) x 3-1/2
20d (0.192) x 2-1/2
8d (0.131) x 1-1/2
10d (0.148) x 1-1/2
10d (0.148) x 3
16d (0.162) x 3-1/2
8d (0.131) x 1-1/2
10d (0.148) x 1-1/2
8d (0.131) x 2-1/2
10d (0.148) x 3
16d (0.162) x 3-1/2
8d (0.131) x 2-1/2
10d (0.148) x 3
16d (0.148) x 3-1/4
16d (0.148) x 3-1/2 Ring Shank
16d (0.162) x 3-1/2
20d (0.192) x 4
& 8
!1+2#-!*#/,
&
8!1+2#-!*#/,
&
8 !1+2#-!*#/,
&
8
!1+2#-!*#/,
Dia
3.33
3.76
3.76
4.11
4.11
4.88
3.33
3.76
3.76
4.11
3.33
3.76
3.33
3.76
3.76
3.33
3.76
3.76
3.76
4.11
4.88
2.77
3.10
3.10
3.86
Length
38.1
38.1
76.2
63.5
88.9
63.5
38.1
38.1
76.2
88.9
38.1
38.1
63.5
76.2
82.6
63.5
76.2
82.6
88.9
88.9
101.6
63.5
76.20
82.60
88.9
14
1-800-328-5934 www.USPconnectors.com
Installation:
Factored shear values assume nail embedment into the wood of the entire nail or 8 nail diameters (whichever is less).
Load reductions may occur if nails are used other than those specified. See the chart Optional Nails for Face Mount Hangers
on page 15 for load reduction factors regarding nail substitutions.
NA9D/NA10D
N10-GC
N10C
N10C-GC NA16D-RS
.148 x 3
NA16D
N16C
N16C-GC
NA20D
Fasteners
Replacement
Fastener
Resistance
Adjustment Factor
0.88
0.82
0.73
0.90
0.71
0.86
0.86
0.61
0.61
0.90
0.78
1.00
1) This chart does not apply to hangers modified to skew and/or slope, or
steel thinner than 14 gauge.
2) This chart does not apply to HUS, JUS, MSH, MUS or THDH slant nail hangers.
How to Use:
The base value is the catalogue listed nail in
Douglas Fir-Larch and the adjustment factor is the
multiplier for the applicable replacement nail and
wood combination.
JL210 listed factored vertical resistance is 2180 lbs when connected onto
SPF header, using 10d common nails.
If substituting:
8d common: 2180 lbs x 0.82 = 1787 lbs
10d spiral: 2180 lbs x 0.73 = 1591 lbs
1-800-328-5934 www.USPconnectors.com
USP2240-131
15
Fasteners
Serrations
Screw shear capacities are based on a diameter of 0.242 when the shear plane
is on the screw shank (SH) and 0.185 when the shear plane is on the knurl or
threads (T). USP WS Wood Screws have a bending yield strength of 180,000
psi.
SH
1/4 Beveled reamer
on 2 1/2 or longer
Wood Screws
L
T
Cut threads
Installation:
Screws are self-drilling.
Install using a low speed clutch drill with 3/8 hex head driver. The washer
head should be flat to the surface and the serrations will oppose turning and
release the clutch. Do not over-tighten the screws.
Installing the screw at an angle may introduce additional bending and tension
forces into the fastener if the screw head is not flat on the bearing surface. Care
should be given to ensure the fastener is installed perpendicular to the plane of
the side plate.
WS
USP name
Screw length
3/8
Description
Dimensions (in)
2,3,4,5
DF-L
Wood
to Wood
USP
Stock No.
in
mm
SH
Finish
SDS25112
6.1 x 38
1-1/2
1/4
1-1/4
Zinc
-- --
6.1 x 38
1-1/2
1/4
1-1/4
GC
WS2
SDS25200
6.1 x 50.8
1/4
1-3/4
Zinc
WS25
SDS25212
6.1 x 63.5
2-1/2
1/4
Zinc
WS3
SDS25300
6.1 x 76.2
3/4
Zinc
WS35
SDS25312
6.1 x 88.9
3-1/2
3/4
2-1/2
Zinc
WS45
SDS25412
1-1/4
Zinc
WS6
SDS25600
1-3/4
Zinc
WS15
WS15-GC
16
Ref. No.
6.1 x 152.4
Unit
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
(DF-L
to DF-L)
-- --- --- --- --- --- -323
1.44
387
1.72
452
2.01
543
2.42
543
2.42
S-P-F
Steel to Wood
14
Gauge
10
Gauge
7
Gauge
3
Gauge
100%
358
1.59
358
1.59
423
1.88
487
2.17
552
2.46
616
2.74
680
3.02
680
3.02
100%
496
2.21
496
2.21
561
2.49
625
2.78
690
3.07
754
3.36
825
3.67
825
3.67
100%
660
2.93
660
2.93
724
3.22
789
3.51
853
3.80
918
4.08
997
4.44
997
4.44
100%
807
3.59
807
3.59
1031
4.58
1031
4.58
1031
4.58
1031
4.58
1031
4.58
1031
4.58
1-800-328-5934 www.USPconnectors.com
Wood
to Wood
(S-P-F
to S-P-F)
-- --- --- --- --- --- -277
1.23
332
1.48
387
1.72
480
2.14
480
2.14
Steel to Wood
14
Gauge
10
Gauge
7
Gauge
3
Gauge
100%
332
1.48
332
1.48
387
1.72
443
1.97
498
2.21
553
2.46
618
2.75
618
2.75
100%
471
2.09
471
2.09
526
2.34
582
2.59
637
2.83
692
3.08
763
3.40
763
3.40
100%
635
2.83
635
2.83
691
3.07
746
3.32
801
3.56
857
3.81
890
3.96
890
3.96
100%
692
3.08
692
3.08
900
4.00
900
4.00
900
4.00
900
4.00
900
4.00
900
4.00
Fasteners
The installation instructions and design example shown below are intended for a design professional who will be
responsible for determining the location and number of wood screws to adequately transfer all loads on the truss.
Installation:
Screw spacing shall not be greater than 24 on centre and less than 4 on centre. However, the location of any
individual screw may be adjusted up to one-half the required screw spacing to avoid lumber defects or interference
with other hardware.
Load or hanger spacing shall not be greater than 24 centre-to-centre.
The last truss ply must have a minimum of 11/4 of screw penetration and no more than 1/8 gap between each ply.
Screws cannot be installed through metal truss plates unless the Truss Engineer approves predrilling.
On 2x4 members, use one row of wood screws. On 2x6 and 2x8 use two rows, and on 2x10 use three rows. Stagger
all rows.
The truss bottom chord shall have lateral bracing installed as called out by the Truss Engineer to prevent any
displacement from torsional forces.
1 min. Recommended (Typ)
Install screws from one side
4 min
End of
without flipping the truss.
chord
Top and bottom chords
require screws and in some
1 1/2 Min.
cases the webs may require
1
/
2 2 Min.
screws.
All lateral bracing should be
1 1/2 Min.
attached to each truss ply.
Increase edge and end
Spacing
Spacing
distances if wood splitting
Start screws on
4 min. 24 max.
4 min. 24 max.
occurs.
face that carries
hanger on load
Description
USP
Stock No.
WS3
WS45
WS6
Ref. No.
in
mm
SDS25300
0/ 0
/
SDS25412
0/
0 /
SDS25600
0/0 /
Length (in)
L
3
6
SH
3/4
Shear
Plane
Finish Location
Zinc
SH, T
Zinc
SH, T
Zinc
SH, T
T
2
3
4
S-P-F
kN
1.72
2.42
2.42
Lbs
332
480
480
kN
1.48
2.14
2.14
+')*"*+&-$,*+)%"&"&')&."+!$,*
2) The Truss Engineer shall apply all applicable adjustment factors.
'*)*'&0+!"#.''*"%%)*"&%"&%%)*' *%.''*("*
*).*!&#+!)*
New products or updated product information are designated in red font.
Design Example
Required Loads:
Bottom Chord Load: 500 plf
Top Chord Load: 60 plf
1-800-328-5934 www.USPconnectors.com
17
Fasteners
Serrations
Installation Notes:
For 2 ply members, wood screws shall be installed with
the screw heads in the loaded ply.
For 3 or 4 ply members, wood screws shall be installed in
both outer plies.
Designer shall specify all wood screws locations.
Increase edge and end distances if wood splitting occurs.
Stagger all screws installed into the opposite face.
A minimum of 2 rows of screws shall be used for all
members with H = 5 1/2 and larger.
Wood Screws
L
T
Cut threads
USP
Stock No.
Ref. No.
Description (in)
SH
WS35
SDS25312
<9 <
3-1/2
3/4
2-1/2
WS6 8
SDS25600
<9<
1-3/4
Multiple
Members
Installation
Figure3,9,10
1
2
4
5
3
6
kN/m
24.74
18.53
18.53
16.49
21.23
74.43
3 Rows
Lbs/ft
2545
1910
1910
1695
2185
7640
kN/m
37.14
27.87
27.87
24.74
31.89
111.50
2 Rows
Lbs/ft
1130
850
850
755
970
3400
kN/m
16.49
12.40
12.40
11.02
14.16
49.62
3 Rows
Lbs/ft
1695
1270
1270
1130
1455
5100
kN/m
24.74
18.53
18.53
16.49
21.23
74.43
2 Rows
Lbs/ft
850
635
635
565
730
2550
3 Rows
kN/m
12.40
9.27
9.27
8.25
10.65
37.21
Lbs/ft
1270
955
955
850
1090
3820
kN/m
18.53
13.94
13.94
12.40
15.91
55.75
1) Factored Resistance values determined in accordance with CSA O86-09 Clause 10.11.
0#&4#3'$#4'&0/8+5*#/'26+7#-'/5
#/+&'.'.$'35*+%,/'440(/05-'445*#/
<#$-'7#-6'4.#:$'+/%3'#4'&$:8*'/64+/)8+5*#/'26+7#-'/5
0#&7#-6'4&'1+%5'ƾ.'5*#55*'6/+(03.-0#&+4#11-+'&505*'.045/#33080654+&'1-:0/-:
4) Except for Figure 6 installation, load values neglect any contribution of screws installed to opposite side, even if they extend significantly into the loaded ply.
0#&4#3'(03/03.#-
&63#5+0/0(-0#&#/&.#:$'+/%3'#4'&+/#%%03&#/%'8+5*5*'%0&'
/+(03.-0#&4+/5#$-'3'13'4'/55*'%#1#%+5:0(5*'(#45'/'34*'%#1#%+5:0(5*'!03$'#..#:$'-'44#/&4*06-&$'%*'%,'&$:#26#-+(+'&&'4+)/'3038+5*5*'.#/6(#%563'34-+5'3#563'
26#-+(+'&&'4+)/'34*#--'/463'5*'#&'26#%:0(#<8+&'$'#.503'4+455*'#11-+'&-0#&0/0/''&)'05*'38+4'5*'-0#&44*#--$'6/+(03.-:&+453+$65'&#%30445*'8+&5*03#11-+'&'26#--:0/$05*4+&'4
"00&4%3'84-0/)'35*#/
<#3'/053'%0..'/&'&(0364'8+5*#3#--#.;03+.$'353#/&;
03+)63'*'*'#&0(5*'800&4%3'8+40/5*'4#.'4+&'#45*'-0#&'&1-:
03+)63'4
#/&5#))'35*'4%3'840/01104+5'(#%'$:*#-(.+/+.6.41#%+/)3'26+3'.'/54
'8130&6%540361'&130&6%5+/(03.#5+0/#3'&'4+)/#5'&+/red font.
Figure 2
Figure 1
Figure 3
Figure 4
Figure 5
Figure 6
WS6 installed
in (4) 13/4 Ply
WS35 installed
in (1) 13/4,
(1) 31/2 Ply
WS35 installed
in (2) 13/4,
(1) 31/2 Ply
WS6 installed
in (2) 31/2 Ply
1 1/2
min
H
2 1/2
min
End of member
2 1/2
min
1 1/2
min
18
Spacing
4 min. 24 max.
Spacing
4 min. 24 max.
1-800-328-5934 www.USPconnectors.com
4 min
Dimensions (in)
SH
Uniform/Distributed Load
Fasteners
The following information pertains to the use of the USPs WS6 Wood Screws to fasten together a two-ply 4x2 floor truss
girder, such that the induced loads are supported by both truss plies. Screw spacing and the location of each specific
screw may vary depending on the design criteria for each application, and therefore must be determined by the truss or
building designer. However, in the determination of screw locations, the following criterion shall also be considered.
These criterion are varying dependent upon how trusses are loaded as follows:
Uniform/Distributed Load
Concentrated/Point Load
Applied Concentrated Load
WS6 Wood Screw
Concentrated/Point Load
Additional
WS6 Wood Screw
if necessary
12
max
Truss Members
3 1/2
3 1/2
DF-L
Ref. No.
SDS25600
Lbs
672
kN
2.99
S-P-F
Lbs
591
kN
2.63
Typ. @ all
members
1 1/2
1-800-328-5934 www.USPconnectors.com
5/8 - 7/8
Screw Detail
USP2240-131
19
Fasteners
T20 Torx
head
Screw
length
Screw shear capacities are based on a diameter of 0.162 when the shear plane
is on the screw shoulder (SH) and 0.109 when the shear plane is on the
threads (T). LumberLok Structural Connector Screws have a bending yield
strength of 180,000 psi.
SH
Installation:
Screws are self-drilling.
Install using a low speed clutch drill with T20 Torx bit. The washer head
should be flat to the surface. Do not over-tighten the screws.
Installing the screw at an angle may introduce additional bending and tension
forces into the fastener if the screw head is not flat to the bearing surface. Care
should be given to ensure the fastener is installed perpendicular to the plane of
the fastener hole.
LL915
Dimensions (in.)
DF-L
Shear
USP
Stock No. Ref. No.
Description
SH
Finish2
LL915
SD9112
#9 x 1-3/8
1-3/8
1/4
1-1/8
GC
LL930
SD9212
#9 x 2-7/8
2-7/8
1-3/8
1-1/2
GC
Unit
Lbs
kN
Lbs
kN
S-P-F
Steel-to-Wood
Twin-lead
threads
Steel-to-Wood
Shear
Shear
Shear
Wood-to- Withdrawal
Wood-to- Withdrawal
Wood
Capacity 18 Ga 16 Ga Wood
Capacity 18 Ga 16 Ga
237
190
208
180
173
191
-- --- -1.05
0.85 0.93
0.80
0.77 0.85
-- --- -228
288
249
265
196
219
226
243
1.01
1.28
1.11 1.18
0.87
0.97
1.01 1.08
Sharp Gimlet
point
1) Factored Resistance values determined in accordance with CSA O86-09 Section 10.11.
2) GC = Gold Coat over Clear Zinc Trivalent.
3) Factored shear resistance for steel-to-wood assumes a side plate tensile strength of 45 ksi.
4) Withdrawal loads for steel-to-wood connections assume a side plate thickness of 1/4" or less.
1
5) Shear loads for wood-to-wood connections assume a side member thickness of 1 /2".
6) Loads are for 100% duration of load factors, and may be increased for other duration factors allowed per governing building code.
New products or updated product information are designated in red font.
LL930
Dimensions (in)
USP
Stock No.
LBP12-TZ
LBP58-TZ
LBPS12-TZ
LBPS58-TZ
HBPS12
HBPS34
HBPS58
BP12
BP582
T
PT
BP583
BP343
L
W
Typical Bearing
Plate installation
20
BP/LBP
Standard
Bearing Plate
L
W
HBPS/LBPS
Slotted Bearing Plate
1-800-328-5934 www.USPconnectors.com
Ref. No.
LBP1/2,
LBP1/2Z
LBP5/8,
LBP5/8Z
LBPS1/2,
LBPS1/2Z
LBPS5/8,
LBPS5/8Z
BPS1/2-3
BPS3/4-3
BPS5/8-3
BP1/2
BP5/8-2
BP5/8,
BP5/8-3
BP3/4-3
Plate
Thickness
(T)
Bolt
Dia.
(in)
10 Ga
9/64
1/2
10 Ga
9/64
5/8
10 Ga
9/64
1/2
10 Ga
9/64
5/8
3 Ga
3 Ga
3 Ga
7 Ga
7 Ga
1/4
1/4
1/4
3/16
3/16
3
3
3
2
2
3
3
3
2
2
1/2
3/4
5/8
1/2
5/8
3 Ga
1/4
5/8
3 Ga
1/4
3/4
CIA-GEL 7000-C
CIA-GEL 7000
CIA-GEL 6000-GP
CIA-EA Series
Epoxy acrylate structural adhesive.
Miracle Bond
Multi-purpose bonding and repair epoxy.
DUC Series
Ductile Undercut Anchors.
Miracle Bond
CIA-EA
Wedge-Bolt+ Series
Screw anchor.
DUCSB
DUC
Power-Stud HD5
Wedge-Bolt+
WM Series
Welded wire mesh.
CR Series
Concrete reinforcing rod.
CR
WM48
SAL
RCD &RCT
Rod chairs hold reinforcing bars for proper placement during the
pouring or application of concrete.
SCV &SCH
Safety caps to protect against injuries from rebar.
TWTT
TW
RCT
RCD
ABS12
Anchor bolt stabber for placement in wet concrete.
THR Series
Threaded rod.
SCV
CRE24
Epoxy coated rebar.
SCH
CRE24
NSR
RP6
ABS12
NSR
Nail stake secures form boards to prevent movement and bowing.
RP6
Oversized plate to distribute forces on masonry surface.
THR
FT
WG
Wedge for FT tie.
RKS
Kwik strip tie for foundation applications.
1-800-328-5934 www.USPconnectors.com
WG
RKS
USP2240-131
21
STB/STBL
AB
ABP
SFA
SFJA
FA3
ST1-TZ
ST2-TZ
KGLB
KGLBT
Type 2 Series
Heavy-duty adjustable support post for maximum loads.
JP
22
1-800-328-5934
1-800-328-5934www.USPconnectors.com
www.USPconnectors.com
Type 2
KHGLB
Applications:
Anchors All-Thread rod and deformed rebar into concrete
Hold downs into concrete for high seismic zones
Horizontal and overhead anchoring applications (requires special inspection)
NEW
CIA-GEL 7000-C Epoxy is an adhesive designed to attach anchor bolts into concrete that is, or may
become, cracked due to cyclic loading from wind or earthquakes. It may also be used with fully grouted CMU construction. It is a low odor, solvent free, non-shrink, non-sag adhesive. The two-component (resin and hardener) epoxy is supplied in equal volume cartridges, which are combined in a 1:1
ratio when dispensed through the attached mixing nozzle. Either a hand powered or air-powered
dispenser may be used. The cartridges are sealed with a D-plug which opens easily on the jobsite
and allows partially used cartridges to be saved for later use. The epoxy has a two year shelf life when
stored in unopened containers at temperatures between 10C/50F and 25C/77F.
Available in:
10 oz. GEL7C-10
22 oz. GEL7C-22
NEW
Available in:
10 oz. GEL7-10
22 oz. GEL7-22
NEW
Available in:
22 oz. GEL6GP-22
USP2240-131
23
CIA-EA Adhesive Anchoring System is an epoxy acrylate specifically designed to be a high strength,
fast cure structural adhesive for anchoring threaded rod and deformed rebar into uncracked concrete.
It has the added advantage of being formulated to be used in colder temperatures (0C/32F) while
maintaining excellent flowability. CIA-EA may also be used with fully grouted CMU and reinforced
brick construction. It is a 2-component, 100% solids, moisture insensitive adhesive that is ideally suited for a wide range of applications. It is composed of a proprietary blend of solvent free epoxy acrylate resin and is backed by independent research and testing. The epoxy has a 15 month shelf life
when stored in unopened containers at temperatures between 5C/41F to 25C/77F.
Applications:
Anchors All-Thread rod into concrete
May also be used to anchor rebar, started bars and dowels
Applications requiring fast cure times
Cold weather applications
Can be used in horizontal anchoring applications
Can be used in overhead anchoring applications (requires special inspection)
NEW
Available in:
10 oz. EA-10
28 oz. EA-28
24
NEW
Available in:
8.6 oz. MB-9
DUC
Undercut Anchor
UCB
Undercut Drill Bit
Mechanical anchor expanded into a hole that has been undercut at the
bottom using an undercutting drill bit creating a true bearing type anchor
that performs like a cast-in-place headed anchor. Load is transferred into
the concrete through bearing, not friction like traditional expansion
anchors. Excellent performance in seismic and dynamic loading
conditions. Meets ACI 318-02 Appendix D requirements as a code
anchor, including seismic loading, tension zone, and cracked concrete
provisions.
Installation:
Clean the
hole using a
blow-out bulb
or compressed
air.
Insert the
undercut bit
and start the
rotohammer.
Undercutting is
complete when
the stopper
sleeve is fully
compressed
(gap closed).
Insert anchor
into hole. Place
setting sleeve
over anchor
and drive the
expansion
sleeve over
the expansion
coupling.
Apply proper
torque.
lb
dc
db
in
3/8
1/2
5/8
3/4
mm
9.5
12.7
15.9
19
hef
ho
Effective
Expansion
Drilled Hole
Coupling Dia. dc Depth of Stop Bit ho Embedment hef
in
5/8
3/4
1-1/8
mm
Anchor
Length, lb
Ultimate
Tensile
Capacity, Ns
Ultimate
Shear
Capacity, Vs
in
mm
in
mm
in
mm
Lbs
kN
Lbs
kN
3-1/8
79.4
2-3/4
69.9
5-1/2
139.7
4650
20.69
2790
12.41
4-3/8
111.1
101.6
6-3/4
171.5
9690
43.10
5815
25.87
4-1/4
107.9
101.6
177.8
8515
37.88
5110
22.73
5-1/4
133.4
127
203.2
17740
78.91
10645
47.35
177.8
6-3/4
171.5
9-3/4
247.6
127
4-1/2
114.3
7-3/4
196.9
13560
60.32
8135
36.19
203.2
7-1/2
190.5
10-3/4 273.1
28250
125.67
16950
75.40
9-1/2
241.3
228.6
12-1/4 311.2
5-7/8
149.2
127
8-5/8
219.1
20040
89.15
12025
53.49
10-7/8
276.2
10
254
13-5/8 346.1
41750
185.72
25050
111.43
15.9
19
25.4
28.6
1) Factored resistance and shear capacities are for anchors installed at standard edge distance and spacing in
uncracked concrete. For cracked concrete capacities, see the USP Anchoring Systems Design Guide.
1-800-328-5934 www.USPconnectors.com
USP2240-131
25
NEW
nchor
USP
x 1-1/4
x 1-3/4
x 2-1/4
/4 x 3
x 1-3/4
x 2-1/2
/8 x 3
/8 x 4
/8 x 5
/8 x 6
/2 x 2
x 2-1/2
/2 x 3
/2 x 4
Zinc
Plated
Mechanically
Galvanized
7764SD
USP
1314
1318
1384
1322
1354
1394
1324
1326
1356
1396
1328
1358
Usable
SDS 1/4" x 6"
SDS 3/8" x 8"
HD Straight Shank 3/8" x 13"
SDS 1/2" x 10"
SDS-Max 1/2" x 13"
HD Straight Shank 1/2" x 13"
SDS 5/8" x 8"
SDS 5/8" x 12"
SDS-Max 5/8" x 13"
HD Straight Shank 5/8" x 13"
SDS 3/4" x 8"
SDS-Max 3/4" x 13"
Wedge-Bolt+
(Zinc Plated)
3/4 x 4
3/4 x 5
3/4 x 6
3/4 x 8
3/4 x 10
3/8 x 4
3/8 x 5
3/8 x 6
1/2 x 4
1/2 x 5
1/2 x 6
1/2 x 6-1/2
1/2 x 8
USP
Stock No.
1314
1318
1384
1322
1354
1394
1324
1326
1356
1396
1328
1358
Description
SDS 1/4" x 6"
SDS 3/8" x 8"
HD Straight Shank 3/8" x 13"
SDS 1/2" x 10"
SDS-Max 1/2" x 13"
HD Straight Shank 1/2" x 13"
SDS 5/8" x 8"
SDS 5/8" x 12"
SDS-Max 5/8" x 13"
HD Straight Shank 5/8" x 13"
SDS 3/4" x 8"
SDS-Max 3/4" x 13"
Usable
Length
4"
6"
4"
8"
8"
11"
6"
10"
8"
11"
6"
8"
Wedge-Bolt+
(Mechanically Galvanized)
5/8 x 5
/2 x 6
/8 x 3
7282SD
7284SD
7286SD
7288SD
7290SD
7726SD
7728SD
7730SD
7746SD
7748SD
7750SD
7751SD
7752SD
Ref. No.
THD75400H
THD75500H
THD75600H
-- -THD75100H
THD37400HMG
THD37500HMG
THD37600HMG
THD50400HMG
THD50500HMG
THD50600HMG
THD50612HMG
THD50800HMG
THD62500HMG,
Anchor
USP
Anchor
USP
2
1
2
1
Finish Stock No.
Ref. No.
Size (in)
Finish
Stock No.
Ref. No.
Size (in)
7204SD
-- -1/4 x 1-1/4
7282SD
THD75400H
3/4 x 4
7206SD
THD25134H 1/4 x 1-3/4
7284SD
THD75500H
3/4 x 5
Zinc
7208SD
THD25214H 1/4 x 2-1/4
7286SD
THD75600H
3/4 x 6
Plated
7210SD
THD25300H
1/4 x 3
7288SD
-- -3/4 x 8
7220SD
THD37134H 3/8 x 1-3/4
7290SD
THD75100H
3/4 x 10
7222SD
THD37212H 3/8 x 2-1/2
7726SD
THD37400HMG
3/8 x 4
7224SD
THD37300H
3/8 x 3
7728SD
THD37500HMG
3/8 x 5
7226SD
THD37400H
3/8 x 4
7730SD
THD37600HMG
3/8 x 6
7228SD
THD37500H
3/8 x 5
7746SD
THD50400HMG
1/2 x 4
7230SD
THD37600H
3/8 x 6
7748SD
THD50500HMG
1/2 x 5
7240SD
THD50200H
1/2 x 2
7750SD
THD50600HMG
1/2 x 6
Zinc
7242SD
THD50212H 1/2 x 2-1/2
7751SD
THD50612HMG 1/2 x 6-1/2
Plated 7244SD
THD50300H
1/2 x 3
7752SD
THD50800HMG
1/2 x 8
Mechanically
THD62500HMG,
7246SD
THD50400H
1/2 x 4
7764SD
5/8 x 5
Galvanized
THDB62500HMG
7248SD
THD50500H
1/2 x 5
THD62612HMG,
7250SD
THD50600H
1/2 x 6
7766SD
5/8 x 6
THDB62600HMG
7268SD
THD50800H 1/2 x 6-1/2
7252SD
THDA62300H 1/2 x 8
7768SD
THDB62612HMG 5/8 x 6-1/2
THD62800HMG,
7260SD
THD62400H
5/8 x 3
7770SD
5/8 x 8
THDB62800HMG
7262SD
THD62500H
5/8 x 4
7264SD
THD62600H
5/8 x 5
7786SD
-- -3/4 x 6
7266SD
THD50612H
5/8 x 6
7789SD
THD75812HMG 3/4 x 8-1/2
7270SD
THD62800H
5/8 x 8
7790SD
THD75100HMG
3/4 x 10
7280SD
-- -3/4 x 3
1) The anchor size includes the diameter and length of the anchor measured from under the head.
2) Wedge-Bolt+ is marked with a blue tip and must be installed with a matched tolerance Wedge-Bit.
Wedge-Bit
Anchor
Wedge-Bolt+
7766SD
5/8 x 6
8
The 7770SD
Power-Stud HD55/8 xanchor
is a fully
threaded, torque-controlled, wedge expansion
anchor. Suitable base materials include normal-weight concrete and structural sand-lightweight concrete. The anchor is manufactured
with a hot-dip galvanized carbon steel body
and stainless steel expansion clip. Nut and
washer are included.
NEW
26
USP
Stock No.2
7723HD5
7724HD5
7726HD5
7733HD5
7734HD5
7738HD5
Ref. No.
WA50414MG
WA50512MG
WA50700MG
-- -WA62600MG
-- --
Anchor
Size (in)1
1/2 x 4-1/2
1/2 x 5-1/2
1/2 x 7
5/8 x 5
5/8 x 6
5/8 x 8-1/2
Thread
Length (in)
2-3/4
3-3/4
5-1/4
3
4
6-1/2
Power-Stud HD5
1-800-328-5934 www.USPconnectors.com
4"
6"
4"
8"
8"
11"
6"
10"
8"
11"
6"
8"
USP
Steel
Stock No. Ref. No. Gauge
SAL36
-- -3
SAL42
-- -3
SAL48
-- -3
SAL60
-- -3
SAL72
-- -3
SAL91
-- -3
W1
Dimensions (in)
W1
3-1/2
3-1/2
3-1/2
3-1/2
3-1/2
3-1/2
W2
3-1/2
3-1/2
3-1/2
3-1/2
3-1/2
3-1/2
L
W2
L
36
42
48
60
72
91
SAL
Typical SAL
installation
Ref. No.
Steel
Gauge
-- --- --
9
9
Materials: 3 gauge
Finish: Red primer
Dimensions (in)
W
48
60
96
600
Typical WM
installation
WM
Concrete Reinforcing Rod provides added strength and stability for any
concrete projects.
Materials: Carbon steel conforms to A615 Steel
Finish: None
USP
Stock No.
CR12
CR24
CR36
CR48
CR72
CR96
Dimensions
Ref. No.
-- --- --- --- --- --- --
D
10 mm
10 mm
10 mm
10 mm
10 mm
10 mm
L
CR
Typical CR
installation
USP
Stock No. Ref. No.
TW1
-- -TW3
-- --
Steel
Gauge
Length
18
16
6"
340'
TW
Typical TW
Installation
1-800-328-5934 www.USPconnectors.com
TWTT
Typical TWTT
Installation
USP2240-131
27
USP
Stock No. Ref. No.
Description
RCD
-- -Double Rod Chair
RCT
-- -Triple Rod Chair
RCD
Typical RCD
installation
RCT
Typical RCT
installation
Dimensions
(in)
4 x 5 x 8-1/4
3-1/2 x 4 x 12
Bright orange safety caps protect against injuries from vertical rebar.
Materials: Composite Plastic
Finish: None
USP
Stock No. Ref. No.
SCH
-- -SCV
-- --
Description
Horizontal Safety Cap
Vertical Safety Cap
SCV
Typical SCV
installation
SCH
Typical SCH
installation
Dimensions (in)
2-3/8 x 2-1/2 x 2-1/2
3-1/4 x 3-3/4 x 3-3/4
For accurate placement of 1/2 (12.7 mm) anchor bolts in wet concrete. The
outstanding legs are different lengths, with the shorter leg centering the anchor
bolt in a 2 x 4 sill plate and the longer leg centering the anchor bolt in a 2 x 6
sill plate.
Materials: Composite Plastic
Finish: See chart
Patents: Pending
Installation:
Slide ABS over anchor bolt and screw on cap.
Place bolt in wet concrete using guides for proper edge distance.
USP
Stock No.1
ABS12
Bolt Dia.
(in)
Ref. No.
Color
-- -1/2 orange
Typical ABS12
installation
ABS12
28
1-800-328-5934
1-800-328-5934www.USPconnectors.com
www.USPconnectors.com
USP
Stock No.
THR125-HDG
THR126-HDG
THR128-HDG
THR1218-HDG
THR1224-HDG
THR1236-HDG
THR585-HDG
THR588-HDG
THR5812-HDG
THR5816-HDG
Bolt Dia.
(in)
Ref. No.
RFB#4X5HDG
1/2
RFB#4X6HDG
1/2
RFB#4X8HDG
1/2
-- -1/2
-- -1/2
-- -1/2
RFB#5X5HDG
5/8
RFB#5X8HDG
5/8
RFB#5X12HDG
5/8
RFB#5X16HDG
5/8
NEW
SIZES
L
(in)
5
6
8
18
24
36
5
8
12
16
Typical THR
installation
THR
" THR
Threaded
Rod
DTB-TZ
Page 195
Typical THR
Deck to ledger installation
Installation:
Install into wet concrete or drill minimum 116" oversized hole and secure
with anchor epoxy.
Nuts and washers are included.
USP
Stock No.
CRE24
Dimensions
Ref. No.
-- --
Dia
10 mm
L
24"
Typical CRE24
installation
CRE24
Nail stakes are used to secure form boards to prevent movement and
bowing.
Materials: Steel
Finish: Black Primer
Installation:
Fastener holes will accommodate up to a 16d duplex nail.
USP
Stock No.
NSR
Dimensions (in)
Ref. No.
-- --
Dia
3/4
L
18
Typical NSR
installation
NSR
Installation:
Install with a 3/4 diameter steel threaded rod.
USP
Stock No. Ref. No.
RP6
RP6
3
3/4 dia.
threaded rod
3
6
RP6
1-800-328-5934 www.USPconnectors.com
Typical RP6
installation
USP2240-131
29
11/16
3 5/8
Installation:
Use the Spacing Guide chart to determine spacing between
FT units. Each level in chart assumes 12 form boards. Wall
thickness from 6 to 12.
Install with V facing up.
Use (2) WG wedges for each tie. Insert wedge into inside slots
for 1x nominal forms and outside slots for 2x nominal forms.
No walers or stiff-backs are used.
Vertical ties to keep forms from separating are not included.
Form deflection may be substantial. Check deflection, if it is
critical, and move ties to compensate.
Forming lumber is assumed to have fb of 1,000 psi.
Not recommended for pours greater than 4 feet in height.
3/16
must order
separately
WG Wedge
Typical FT/WG
installation
W
FT
Spacing Guide chart
USP
Stock No.
FT6
FT8
FT10
FT12
WG
Steel
Ref. No. Gauge
WT6
18
WT8
18
WT10
18
WT12
18
W1
14
Dimensions (in)
W
5/8
5/8
5/8
5/8
11/16
L
10-5/8
12-5/8
14-5/8
16-5/8
3-5/8
Concrete
Lift Height
Wedge
Qty
2
2
2
2
-- --
Footing Width
Type or Wall Thickness
WG
6
WG
8
WG
10
WG
12
-- --- --
Level 1
1x
2x
Level 2
1x
-- -
Level 3
2x
-- -
1x
-- --- -
2x
-- --- -
Level 4
1x
-- --- --- -
2x
-- --- --- -
Water
bar
installed
Materials: 18 gauge
Finish: G90 galvanizing
Stake every
2 feet
1 x 3 cleat
every 2 feet
RKS
USP
Steel
Stock
Ref. No. Gauge
No.
RKS200
-- -18
30
Dimensions
W
Footing Width or
Wall Tickness
3/4
12-1/8
approximates 8"
1-800-328-5934
1-800-328-5934www.USPconnectors.com
www.USPconnectors.com
Typical RKS
installation
Installation:
Select appropriate STB or STBL Anchor Bolt.
Use normal weight concrete with minimum compressive strength of 2,500 psi.
Minimum centre-to-centre spacing between bolts is 3(E) for anchors acting
simultaneously in tension.
Match embedment depth with embedment line on the STB or STBL shaft.
The STB or STBL does not need to be tied to the rebar.
Nuts and washers are not included.
Use USPs ABS12 anchor bolt stabber to hold anchor bolt in place during installation.
STBL Designed for use with 3x sill plates. Excellent choice for
use with taller holdown washers like those in the PHD/PHDA
series.
Monolithic or Stem Wall Foundations Prior to pour, install the STB or STBL in an upright
position and at a 45 angle to the wall. Install one horizontal #4 rebar at a depth of 4 (minimum). (See illustrations.)
Concrete Block Applications Prior to cell pour, install the STB or STBL in an upright
position and at a 45 angle to the wall. (See illustrations.) Use the embossed angle guide
on the end of the STB or STBL shaft as a guide. Install one horizontal #4 rebar at a depth
of 4 and one vertical #4 rebar maximum 48 o.c. spacing. Fill all cells with concrete having
a minimum 2,000 psi compressive strength.
USP2240-131
31
Typical STB/STBL
concrete block installation
Mono Pour
STB16
STBL16
Corner
installation
STB20
STBL20
STB24
STBL24
Non-Corner
installation
Corner
installation
STB28
STBL28
* Recommend installation of
washer under nut of anchor bolt.
1) STBL model are recommended
for use with PHD and UPHD8
holdowns on (2) 2x and 3x
sill plates.
0 Outside edge
of concrete
Dimensions (in)
USP
Stock No.
Ref. No.
Stemwall
Width
Dia.
Min.
Embed. (E)
STB16
SSTB16
5/8
17-13/16
12-13/16
STB20
SSTB20
5/8
21-13/16
16-13/16
STB24
SSTB24
5/8
25-13/16
20-13/16
STB28
SSTB28
7/8
31
26
STB34
SSTB34
7/8
36
30
STB36
SSTB36
7/8
38
30
STBL16
SSTBL16
5/8
19-9/16
6-3/4
12-13/16
STBL20
SSTBL20
5/8
23-9/16
6-3/4
16-13/16
STBL24
SSTBL24
5/8
27-9/16
6-3/4
20-13/16
STBL28
SSTBL28
7/8
32-3/4
6-3/4
26
Midwall
5920
26.33
7170
31.90
8385
37.30
14140
62.90
15980
71.09
15980
71.09
5920
26.33
7170
31.90
8385
37.30
14140
62.90
32
1-800-328-5934
1-800-328-5934www.USPconnectors.com
www.USPconnectors.com
Materials: Bolt: ASTM F 844, Nut: ASTM A 563, Washers: ASTM F 844
Finish: AB126-HDG, AB128-HDG, AB1212-HDG, AB5812-HDG
Hot-dip galvanized; All others none
Installation:
Select appropriate AB or ABP Anchor Bolt.
Use concrete with minimum compressive strength of
2,000 psi at 28 days
Nuts and standard washers are included.
Anchor bolts intended for use to satisfy code
prescribed anchoring of mudsill plates, and shall be
installed as defined in the code.
Factored resistance shall be derived in accordance
with the code.
Typical AB
installation
L
USP
Stock No.
AB126-HDG
AB128-HDG
AB1212-HDG
AB5812-HDG
AB6NW
AB8NW
ABP6NW
ABP8NW
Ref. No.
-- --- --- --- --- --- --- --- --
Bolt
Dia. (in)
1/2
1/2
1/2
5/8
1/2
1/2
1/2
1/2
L
(in)
6
8
12
12
6
8
6
8
Anchor Bolts are used to secure wood plates to foundation walls. Washers are
available in various package combinations.
ABP
AB
F1
Materials: 12 gauge
Finish: G90 galvanizing
Installation:
Use all specified fasteners. See Product Notes, page
10.
A design professional must specify anchor bolt type, length,
and embedment. Anchor bolts are laterally loaded. Follow
installation instructions for epoxy adhesive.
Factored resistance assume a minimum concrete compressive
strength of 2,000 psi.
USP
Steel
Stock No. Ref. No. Gauge
SFJA
FJA
12
SFA8
-- -12
Framing
Qty
1
2
Dia.
5/8
1/2
Nails2,4
Qty
-- -7
Type
-- -10d x 1-1/2
SFA8
Factored Resistance1
Fastener Schedule
Anchor
Bolts
DF-L
Bolts3
Qty
2
-- --
Dia.
5/8
-- --
S-P-F
F1
Uplift
F1
Uplift
115%
-- -1085
115%
1620
-- --
115%
-- -915
115%
1360
-- --
1) The 115% values are short-term loads such as wind and earthquake.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) Bolts shall conform to ASTM A 307 or better.
4) NAILS:
red font.
1-800-328-5934 www.USPconnectors.com
1 1/2
6
Uplift
6 1/2
Typical SFJA
installation
1 1/2
SFJA
USP2240-131
33
Materials: 16 gauge
Finish: G90 galvanizing
Options: FA3 is available in Triple Zinc.
To order, add TZ to end of stock number,
as in FA3-TZ.
Codes: Load values are derived from data submitted to
various North American building code
evaluators.
4 5/8
5 3/4
1,9
USP
Stock No
Ref. Steel
No. Ga.
Stud
Side Top
W
IE
D Qty Qty
Type
Qty
Uplift
F2
Fastener Schedule
Sill Plate
Plate
Size
F1
Alternate FA3
installation
Dimensions (in)
FA3
Installation:
Use all specified fasteners. See Product Notes, page 10.
Use a minimum of two anchors per mudsill. An anchor should always be
within 12 of the end of each mudsill section.
Do not rely on these anchors to secure concrete sections together between
cold joints.
Insert into wet concrete (minimum strength of 2,000 psi). Place mudsill after
concrete cures. Secure flanges to sill (and stud, if applicable), bending flanges
as needed to achieve a tight fit. Fasten as directed in chart.
Embossed lines
provide guide for
matching to edge
of form board
Type
For installation into concrete slabs. The FA3 features a split flange for nailing
to both mudsill and stud for greater framing versatility.
1 1/2
2,3,5,6,7
Uncracked Concrete
FA3
2 x4
Mudsill Only
MAS
or
FA3
2x6
Mudsill & Stud
16
1-1/2 4-5/8
-- --
4 10d x 1-1/2 -- --
1
6
Lbs
kN
Lbs
kN
1045
4.65
780
3.47
645
2.87
635
2.82
760
3.38
480
2.14
1045
4.65
780
3.47
645
2.87
635
2.82
760
3.38
480
2.14
900
4.00
670
2.98
555
2.47
545
2.42
655
2.91
415
1.85
900
4.00
670
2.98
555
2.47
545
2.42
655
2.91
415
1.85
1010 62
755
61
1020
4.54
780
3.47
565
2.51
565
2.51
760
3.38
480
2.14
875
3.89
780
3.47
485
2.16
485
2.16
670
2.98
480
2.14
875
3.89
670
2.98
485
2.16
485
2.16
655
2.91
415
1.85
755
3.36
670
2.98
415
1.85
415
1.85
575
2.56
415
1.85
985
54
755
54
FA3
2 x4
Mudsill Only
MAS
or
FA3
2x6
Mudsill & Stud
2
16
1-1/2 4-5/8
1
2
Cracked Concrete
Lbs
4 10d x 1-1/2 -- --- -6
kN
Lbs
2 10d x 1-1/2 2 10d x 1-1/2
6
kN
34
1-800-328-5934
1-800-328-5934www.USPconnectors.com
www.USPconnectors.com
Materials: 18 gauge
Finish: G-185 galvanizing
Codes: Load values are derived from data submitted to
various North American building code evaluators.
Typical
ST1-TZ
installation
in concrete
Installation:
Use all specified fasteners. See Product Notes, page 10.
Use a minimum of two anchors per mudsill. An anchor should always be
within 12 of the end of each mudsill section.
Do not rely on these anchors to secure concrete sections together between
cold joints.
Spread sill flanges to mudsill width prior to insertion into wet concrete
(minimum strength of 2,000 psi or 13.8 MPa). Alternate installation is
possible by inserting unbent flanges through 3/4 center hole predrilled in
mudsill. Foundation anchors may also be attached to mudsill and then
inserted into wet concrete. When installing ST2-TZ into concrete block, fill cells
with grout with a minimum strength of 2,000 psi or 13.8 MPa. Concrete block
edges may need to be beveled to facilitate installation.
ST2-TZ in masonry construction shall be installed in the core of the block and
grouted with concrete grout designed for that purpose. In no case, shall they
be installed in a mortar joint.
Uplift
F2
Drill 34" dia.
hole
F1
Alternate
ST1-TZ
installation with
3/4center hole
10
DO NOT install
ST1-TZ and ST2-TZ
without pre-bending
sill flanges in Y
configuration
ST2-TZ
ST1-TZ
2,3
Fastener Schedule
Plate
Size
USP
Stock No.
ST1-TZ
2x4-6
ST2-TZ
Alternate
ST2-TZ
installation with
3/4 center hole
in mudsill
Mudsill Top
Mudsill Side
Steel
Ref. No. Gauge Qty
Type
Qty
Type
MAB15,
4 8d x 1-1/2 HDG 4 8d x 1-1/2 HDG
18
MAB15Z
MAB23,
18
4 8d x 1-1/2 HDG 4 8d x 1-1/2 HDG
MAB23Z
Min.
Embed. (in)
(E)
Unit
!
!
Lbs
kN
Lbs
kN
S-P-F
F1
F2
Uplift
F1
F2
Uplift
979
4.36
979
4.36
1134
5.04
1134
5.04
1310
5.83
1310
5.83
839
3.73
839
3.73
972
4.32
972
4.32
1123
4.99
1123
4.99
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase is allowed.
For standard term loads divide the values by 1.15.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) NAILS
!
!
red font.
1-800-328-5934 www.USPconnectors.com
USP2240-131
35
1/2 Min.
clearance
KGLBT Double bolt with Structural Tee provides uplift and horizontal resistance.
Materials: Flanges 1/ 4 steel
Bearing Plate See chart
Anchor dowels 3 4 x 12 rebar
Finish: USP primer
Options: Consult USP for non-catalogue variations.
Codes: Load values are derived from data
submitted to various North American
building code evaluators.
F2
3
W
Dimensions (in)
Bolt Schedule
Rebar welded to
bearing plate
Qty
KGLB5A
KGLB5B
KGLB5C
KGLB5D
KGLB7A
KGLB7B
KGLB7C
KGLB7D
GLB5A
GLB5B
GLB5C
GLB5D
GLB7A
GLB7B
GLB7C
GLB7D
5-1/4
5-1/4
5-1/4
5-1/4
6-7/8
6-7/8
6-7/8
6-7/8
7
7
7
7
9
9
9
9
1/4
3/8
3/8
3/8
1/4
3/8
3/8
3/8
5
6
7
8
5
6
7
8
1
1
1
1
1
1
1
1
Dia.
(in)
5/8
5/8
5/8
5/8
3/4
3/4
3/4
3/4
D
L
1 1/2
1 1/4
12
W
3
3
3 1/2
D
L
4 12
3 1/2
Structural
tee
Concrete3
Lbs
kN
Lbs
kN
16980
20370
23765
27160
22355
26825
31300
35770
75.53
90.61
105.72
120.82
99.44
119.33
139.23
159.12
16980
20370
23765
27160
22355
26825
31300
35770
75.53
90.61
105.72
120.82
99.44
119.33
139.23
159.12
KGLBT
1 1/4
1 1/2
USP
Stock No.
36
Ref. No.
Range
W
Bolt
Schedule
L
KHGLBA
HGLBA
3-1/4 to 9
10
3/8
KHGLBB
HGLBB
3-1/4 to 9
10
3/8
KHGLBC
HGLBC
3-1/4 to 9
10
3/8
KHGLBD
HGLBD
3-1/4 to 9
10
3/8
KGLBT512
GLBT512
3-1/4 to 11
5-1/2
12
1/3
KGLBT612
GLBT612
3-1/4 to 11
6-1/2
12
3/8
KGLBT516
GLBT516
3-1/4 to 15
5-1/2
16
1/3
KGLBT616
GLBT616
3-1/4 to 15
6-1/2
16
3/8
KGLBT520
GLBT520
3-1/4 to 19
5-1/2
20
1/3
KGLBT620
GLBT620
3-1/4 to 19
6-1/2
20
3/8
Dia.
Qty (in) Unit
Lbs
2
3/4
kN
Lbs
2
3/4
kN
Lbs
2
3/4
kN
Lbs
2
3/4
kN
Lbs
2
3/4
kN
Lbs
2
3/4
kN
Lbs
2
3/4
kN
Lbs
2
3/4
kN
Lbs
2
3/4
kN
Lbs
2
3/4
kN
T
D
L
2 1/2
2 1/2
1,5
6-3/4
22355
99.44
26825
119.33
31300
139.23
35770
159.12
24595
109.41
29065
129.29
24595
109.41
29065
129.29
24595
109.41
29065
129.29
KGLB
Concrete pilaster
Installation:
Use all specified fasteners. See Product
Notes, page 10.
Bolt holes shall be a minimum of 1 32 to a
maximum of 1 16 larger than the bolt diameter.
Concrete or masonry walls must be checked
by a design professional for adequacy to resist
lateral or uplift loads transferred from the beam
seat anchor.
USP
Stock
No.
Bearing Plate
8-3/4
28980
128.91
34775
154.69
40570
180.47
46370
206.27
31880
141.81
37680
167.62
31880
141.81
37680
167.62
31880
141.81
37680
167.62
10-3/4
-- --- --- --- --- --- --- --- -39170
174.24
46290
205.92
39170
174.24
46290
205.92
39170
174.24
46290
205.92
F2
3,4
100%
9445
42.02
9445
42.02
9445
42.02
9445
42.02
9445
42.02
9445
42.02
9445
42.02
9445
42.02
9445
42.02
9445
42.02
1-800-328-5934
1-800-328-5934www.USPconnectors.com
www.USPconnectors.com
Min. 3-1/8
Beam Width (W)
Uplift 115%3
4045
17.99
4045
17.99
4045
17.99
4045
17.99
4045
17.99
4045
17.99
4045
17.99
4045
17.99
4045
17.99
4045
17.99
KHGLB
Uplift
Adjustable Support Posts may be used to support carport roofs and beams
carrying loads not more than two wood frame floors, where the length of joists
carried by such beams does not exceed 16 and a live load on any floor does not
exceed 50 lbs/ft2.
Installation:
Elevate top tubing to approximate height and insert locking pin. Rotate jack screw
to desired height, then fasten top plate in position. Ensure top and bottom plates are
properly fastened to supported beam members and properly aligned to the
supported base footing. Always ensure product is installed 90 to beam and footing.
Adjustable Height
USP
Steel
Stock No. Ref. No. Gauge
in
mm
JP24
-- -3
17 - 24 432 - 610
JP60
-- -3
36 - 60 914 - 1524
JP96
-- -3
60 - 96 1524 - 2438
JP108
-- -3
72 - 108 1829 - 2743
Allowable Load1,2
Lbs
8555
8555
8555
8177
kN
38.06
38.06
38.06
36.37
JP
Factored Resistance1,2
Lbs
12319
12319
12319
11775
kN
54.80
54.80
54.80
52.38
1) The loads given above the established in accordance with CAN/CGSB-7-2 for allowable
load design. The factored resistances given above are for Limit States Design in
accordance with the 1995 National Building Code of Canada.
2) The bearing resistance of the supported beam should be checked by the building designer
using the appropriate CSA standard.
Description
Setting Pin
Screw & Nut Assembly
6" x 7" Steel Plate
Screw & Nut Assembly
Top Plate
Qty/
Package
1
1
15
1
1
Typical JP
installation
JPSP
JPSN
JPSSN
JPTP
1-800-328-5934 www.USPconnectors.com
JPCP
USP2240-131
37
&
NEW VED
O
R
IMP SIGN
DE
Copyright 2013 USP Structural Connectors
Meets or exceeds CCMC requirements for a Type 2 Adjustable Steel Column and
may be used to support carport roofs and beams carrying not more than two woodframe floors where the length of the joists carried by such beams does not exceed
16 feet and the live load on any floor does not exceed 50 lbs/ft 2. May also be used
on projects exceeding the prescriptive requirements where a professional engineer
is directly involved and the factored resistance requirements are met.
Installation:
Elevate supported beam to the proper height. Turn threaded collar to extend
post to the desired length. Ensure that the top and bottom plates are properly
fastened to the supported beam and aligned properly with the supporting
foundation. Always ensure product is installed 90 to the beam and footing.
Light Duty Type 2 Column
Adjustable Height
USP
in
Stock No
T2JPLD84
80 - 84
T2JPLD88
84 - 88
T2JPLD90
86 - 90
T2JPLD96
92 - 96
T2JPLD102 98 - 102
T2JPLD108 104 - 108
T2JPLD120 116 - 120
2,3
mm
in
mm
kN
Lbs
kg
kN
Lbs
kg
2032 - 2134
2134 - 2235
2184 - 2286
2337 - 2438
2489 - 2591
2642 - 2743
2946 - 3048
84
88
90
96
102
108
120
2134
2235
2286
2438
2591
2743
3048
75.2
68.9
66.7
60.5
56.9
54.3
48.5
16900
15500
15000
13600
12800
12200
10900
7665
7030
6805
6170
5805
5535
4945
115.8
108.1
105.4
97.4
89.2
82.2
69.8
26000
24300
23700
21800
20050
18400
15600
11813
11020
10750
9936
9095
8385
7119
Type 2 Post
9/16" hole
for height
adjustment
USP
in
Stock No
T2JPHD84
80 - 84
T2JPHD88
84 - 88
T2JPHD90
86 - 90
T2JPHD96
92 - 96
T2JPHD102 98 - 102
T2JPHD108 104 - 108
T2JPHD120 116 - 120
mm
in
mm
kN
Lbs
kg
kN
2032 - 2134
2134 - 2235
2184 - 2286
2337 - 2438
2489 - 2591
2642 - 2743
2946 - 3048
84
88
90
96
102
108
120
2134
2235
2286
2438
2591
2743
3048
176.1
162.8
157.9
142.8
133.4
125.9
119.2
39600
36600
35500
32100
30000
28300
26800
17960
16600
16100
14560
13610
12835
12155
222.5
210.4
206.4
193.5
179.3
167.7
145.5
Lbs
49900
47300
46400
43400
40300
37600
32700
2,3
kg
22687
21455
21045
19728
18280
17104
14838
1) The Allowable Load values have been determined thru testing standards prescribed in
the National Research Council Evaluation Directive for Adjustable Steel Columns using a
safety factor of 2.25.
" !!"&$#! !"! %""
" !!!" !"" #"# !#!!!"" &
3) The bearing resistance of the supported beam should be checked by the building designer
using the appropriated CSA standard.
New products or updated product information are designated in red font.
HEAVY DUTY
ADJUSTMENT ASSEMBLY
FOR MAXIMUM LOADS
MODULAR DESIGN FOR
GREATEST JOB SITE
FLEXIBILITY
SQUARE POST FOR EASY
AND ACCURATE CUT DOWN
38
Adjustment
Assembly
Square Tube
Design
Universal Plate
Type 2 Heavy- Duty Support
Post Accessories on next page
Installation:
Place Heavy-Duty Top Plate on top of standard Type 2 Top Plate.
Align holes in Heavy-Duty Top Plate with holes in standard Type 2 Top Plate.
Install appropriate lag screws through stacked top plates into bottom of
supported beam.
Dimensions (in)
USP
Steel
Stock No. Ref. No. Gauge
T2TP527
-- -3
T2TP79
-- -3
Fastener Schedule
NEW
T2TP79
(T2TP527 similar)
Factored Resistance
DF-L
S-P-F
Bearing (100%)
Bearing (100%)
Qty
Type
Lbs
kN
Lbs
kN
5-1/4
7
7
9
4
4
29300
38500
131
173
22600
34000
101
152
1) Factored resistances are for standard term loading; reduce or increase for other load durations in accordance with the code.
2) Bearing loads are based on compression perpendicular to grain values published in the Canadian Standards Association
CSA-O86-09 and having the top plate in full contact with the supported member.
3) Factored resistances are based on lumber with a specific gravity of DF-L = 0.49 and S-P-F = 0.42 and
a moisture content of 19% or less.
4) Lag Screws are not supplied. WS2 Wood Screws (1/4" dia. x 2" long) may be ordered separately and used in lieu of lag screws.
5) Beams shall be designed to support the required loads. Beam shear may limit loads to less than listed loads for device.
6) The factored resistance of the T2TP may exceed the column capacity. Refer to the Type 2 Column load tables for the
maximum factored resistance based on column length.
7) Spliced conditions must be detailed by the specifier to transfer tension loads between spliced members by means
other than the column top plate.
8) The factored resistance must be reduced according to code when supporting the end of the beam.
New products or updated product information are designated in red font.
Typical T2TP79
installation
(T2TP527 similar)
NEW
Installation:
Replaces standard Type 2 Top Plate.
Slide column cap tube into top of existing threaded pipe component for complete
adjustability.
WS3 Wood Screws, dia. x 3 long, are supplied with T2CC Column Caps.
Dimensions (in)
USP
Stock No.
T2CC35
T2CC525
T2CC71
Ref. No.
----
Steel
Gauge
7
3
3
W
3-5/8
5-1/4
7-1/8
H
6-1/2
8
6-1/2
L
11
13
11
DF-L
S-P-F
Beam
Bearing (100%)
Bearing (100%)
Type
WS3
WS3
WS3
T2CC35
Factored Resistance
Fastener
Schedule4
Qty
16
16
16
Lbs
31270
54115
62540
kN
139.1
240.7
278.2
Lbs
23675
40970
47350
kN
105.3
182.2
210.6
1) Factored resistances are for standard term loading; reduce or increase for other load durations in accordance with the code.
2) Bearing loads are based on compression perpendicular to grain values published in CSA O86-09 and having the bucket base in full contact
with the supported member.
3) Factored resistances are based on lumber with a specific gravity of DF-L = 0.49 and S-P-F = 0.42 and a moisture content of 19% or less.
4) WS3 Wood Screws (1/4" dia. x 3" long) are included with T2CC Column Caps.
5) Beams shall be designed to support the required loads. Beam shear may limit loads to less than listed loads for device.
6) The factored resistance of the T2CC may exceed the column capacity. Refer to the Type 2 Column load tables for the maximum factored
resistance based on column length.
7) Spliced conditions must be detailed by the specifier to transfer tension loads between spliced members by means other than the column cap.
8) The factored resistance must be reduced according to code when supporting the end of the beam.
New products or updated product information are designated in red font.
1-800-328-5934 www.USPconnectors.com
Typical T2CC
installation
USP2240-131
39
Holdowns
PHD
PHDA
TDX
TD
UPHD Series
High capacity holdown. Connects to post with wood screws.
UPHD
Holdowns
HTT
LTS
LTTI31
TDL Series
Light- capacity foundation strap. Bolts to foundation and nails or bolts to
post.
TDL
LSTAD/
STAD
HPAHD
PA
40
1-800-328-5934
1-800-328-5934www.USPconnectors.com
www.USPconnectors.com
PAI
PAHD42
TA
Installation:
Use all specified fasteners. See Product Notes, page 10.
Place the PHD/PHDA over the anchor bolt. No washer is
required.
Install with USPs code evaluated WS3 (1/4 x 3) Wood
Screws, which are provided with the holdown.
Tighten anchor bolt nuts finger tight snug to base, plus 1/3
to 1/2 additional turns with a wrench. To prevent loosening of
the anchor nut during critical loading, use a locking nut or
tighten a second nut over the first to lock nuts in place.
PHD/PHDA Predeflected Holdowns may be installed off
sill plate with no load reduction.
The design engineer may specify any alternate anchorage
calculated to resist the tension load for a specific application.
Anchorage exposure length should take the bearing plate
height of 1 5/8 into account, anchor bolt thread should visibly
extend above nut.
If used to anchor a built-up post, such as a double 2 x 4, the
post component shall be designed to act as a single unit.
Holdown fasteners specified shall not be considered to attach
multiple plies together.
For anchorage options see STBL Anchor Bolt section on
pages 31-32.
Typical PHD5A
installation
H
1 5/8
Holdowns
CL
D
PHD5A
PHD8
USP
Stock No.
PHD2A
PHD4A
PHD5A
PHD8
Ref. No.
HDU2-SDS2.5
HDU4-SDS2.5
HDU5-SDS2.5
HDU8-SDS2.5
Steel
Gauge
14
14
14
12
Anchor Bolts
W
3
3
3
3-1/4
H
7-3/4
9-3/4
11-11/16
16-1/2
D
2-5/8
2-5/8
2-5/8
3
Fastener Schedule
Dimensions (in)
CL
1-3/8
1-3/8
1-3/8
1-3/8
Qty
1
1
1
1
Dia.
5/8
5/8
5/8
7/8
DF-L
Wood Screws
Qty
6
10
14
24
Type
WS3
WS3
WS3
WS3
Lbs
3330
5400
6755
8470
kN
14.81
24.02
30.05
37.68
S-P-F
Lbs
2795
4535
5670
7115
kN
12.43
20.17
25.22
31.65
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) The designer must specify anchor bolt type, length, and embedment.
3) The PHD may be elevated off the sill.
""$#$!"
! $ !
$
1-800-328-5934 www.USPconnectors.com
USP2240-131
41
Holdowns
Installation:
Use all specified fasteners. See Product Notes, page 10.
Do not use lagbolts. Washers are not required for anchor bolts or between holdown and bolt
hex head, but standard washers should be used against stud or post under the nut. See page
20 for BP/LBP Bearing Plates.
Bolt holes should be a minimum of 1 32 to a maximum of 1 16 larger than the bolt diameter.
See pages 31-32 for STB Anchor Bolt section for anchorage options. A design
professional may specify alternate anchorage with conventional anchor bolts.
A design professional shall determine the adequacy of the stud to resist published loads. When
installing to multi-ply 2x studs, the designer must specify the fasteners required to bind the plies
together and resist splitting.
Self-jigging models are designed to provide the required minimum end distance of 7 bolt
diameters from the bottom of the stud or post to the centerline of the first bolt hole.
Tighten anchor bolt nuts to finger tight, plus 1/3 to 1/2 additional turns with a wrench. Wood
members may shrink over time; if possible, nut tightness should be checked periodically. To
prevent loosening of the anchor bolt nut during critical loading, use a locking nut or tighten a
second nut over the first to lock nuts in place.
If used to anchor a built-up post, such as a double 2 x 4, the post component shall be designed
to act as a single unit. Holdown fasteners specified shall not be considered to attach multiple
plies together.
Typical TDX2-TZ
installation
Typical TDX2-TZ
back-to-back
installation
3 1/2
H
End
dist.
9/16
CL
TDX6
Washer required
under anchor
bolt nut
TD15 = 3 3/8
TD9 &
TD12 = 3 1/2
Holdown installation
between floors
42
Typical TD15
installation
Typical TDX6
installation
Moisture barrier
may be required
Dimensions (in)
USP
Stock No.11
TD5
TD7
TD9
TD12
TD15
TDX2-TZ
TDX5
TDX6
TDX8
TDX10
TDX14
continued
Factored Resistance (115%)1,2
Length of Bolt in Vertical Member
1-1/2"
Lbs
1560
1230
2725
2150
-- --- --- --- --- --- -1300
1025
1560
1230
1815
1440
2725
2150
3635
2870
4150
3275
3"
kN
6.94
5.47
12.12
9.56
-- --- --- --- --- --- -5.78
4.56
6.94
5.47
8.07
6.41
12.12
9.56
16.17
12.77
18.46
14.57
Lbs
3115
2460
5450
4300
6225
4915
8310
6555
10385
8195
2525
1795
3115
2460
3635
2870
5450
4300
7270
5740
8310
6555
3-1/2"
kN
13.86
10.94
24.24
19.13
27.69
21.86
36.96
29.16
46.19
36.45
11.23
7.98
13.86
10.94
16.17
12.77
24.24
19.13
32.34
25.53
36.96
29.16
Lbs
3635
2870
6360
5020
7270
5740
9690
7645
12110
9560
2525
1795
3635
2870
4240
3345
6360
5020
8480
6695
9690
7645
kN
16.17
12.77
28.29
22.33
32.34
25.53
43.10
34.01
53.87
42.52
11.23
7.98
16.17
12.77
18.86
14.88
28.29
22.33
37.72
29.78
43.10
34.01
4-1/2"
Lbs
-- --- --- --- -9345
7375
12460
9835
15570
12295
-- --- --- --- --- --- --- --- --- --- --- --- --
5-1/2"
kN
-- --- --- --- -41.57
32.81
55.42
43.75
69.26
54.69
-- --- --- --- --- --- --- --- --- --- --- --- --
Lbs
5710
4510
9995
7890
11420
9015
15225
12025
19035
15025
2525
1795
5695
4510
6665
5260
9995
7890
13325
10515
15225
12025
kN
25.40
20.06
44.46
35.10
50.80
40.10
67.72
53.49
84.67
66.83
11.23
7.98
25.33
20.06
29.65
23.40
44.46
35.10
59.27
46.77
67.72
53.49
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) The designer must specify stud or post to resist published load values.
3) The designer must specify anchor bolt type, length, and embedment.
4) All models may be installed with greater than the required anchor end distance with no chart load reduction.
5) The designer shall consider the effect of compression, bearing, tension, and combined bending due to device eccentricity when applicable.
6) Holdowns raised off of the sill plate may have higher deflection values.
Holdowns
Min.
Required
Bolt End
Anchor
5
Bolt
Steel
Wood
Distance
Ref. No. Gauge
W
H
D
CL
Dia.
Qty Dia.
(in)
Species
DF-L
7
-- -3
6-3/8 3-3/4 2-1/8
3/4
2
3/4
5-1/4
S-P-F
DF-L
3
-- -3-3/8 11-7/8 3-5/8 2-1/8 1-1/8
3
7/8
6-1/8
S-P-F
DF-L
3
-- -3-3/8 16-1/2 4-1/4 2-1/8 1-1/8
3
1
7
S-P-F
DF-L
HD12
3
3-1/2 20-1/2 4-1/4 2-1/8 1-1/8
7
4
1
S-P-F
DF-L
-- -3
1
7
3-1/2
25
4-3/8 2-1/8 1-1/4
5
S-P-F
DF-L
HD3B
12
2
5/8
4-1/2
2-1/16 8-1/8 2-3/4 1-1/2
5/8
S-P-F
DF-L
-- -10
2
2
3/4
5-1/4
2-1/2 9-3/8 3-7/8
3/4
S-P-F
DF-L
7
HD5B
2
7/8
2
6-1/8
3-1/2 11-1/8 3-3/4
7/8
S-P-F
DF-L
7
HD8A
2
7/8
3
6-1/8
3-1/2 14-5/8 3-3/4
7/8
S-P-F
DF-L
7
HD7B
2
7/8
6-1/8
3-1/2 18-1/8 3-3/4
7/8
4
S-P-F
DF-L
HD9B
3
1
3-1/2 20-1/2 3-5/8 2-1/8
7
1
4
S-P-F
E. Nut spin anchor bolt nuts that are not restrained can spin loose during
cyclic loading, allowing movement; the use of steel nylon locking nuts or
thread adhesive may prevent nut spin.
Bearing
Plates
Shearwall
End Post
D
E
H
Holdown
F
G
F. Loose nuts increased movement can occur when nuts are not
sufficiently tightened.
H. Wood Shrinkage due to drying, wood may shrink and cause bolted
connections to become loose; periodic retightening may be required.
1-800-328-5934 www.USPconnectors.com
I
Wood
Sill Plate
Holdown
Anchor Bolt
1
4 x 3 x 3
Steel Plate
Foundation
Concrete
USP2240-131
43
Typical UPHD
installation
CL
D
UPHD
Typical UPHD
concrete
wall installation
Dimensions (in)
USP
Stock No.
Ref. No.
Steel
Gauge
Anchor Bolts
W
Fastener Schedule
CL
3-1/4 17-1/4 3
1-3/8
3-1/4 17-1/4 3-1/2 1-1/2
DF-L
Wood Screws
Dia.(in)
Qty
Type
Lbs
kN
Lbs
kN
1
1
7/8
1
24
24
WS3
WS3
9485
11665
42.19
51.89
7965
9800
35.43
43.59
UPHD8
UPHD9
HDQ8-SDS3
HDU11-SDS2.5
10
10
UPHD11
HHDQ11-SDS2.5
24
WS3
14900
66.28
12515
55.67
UPHD14
HDU14-SDS2.5,
HHDQ14-SDS2.5
30
WS3
17280
76.87
14515
64.57
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other
load durations in accordance with the code.
2) The designer must specify anchor bolt type, length, and embedment.
3) The UPHD may be elevated off the sill.
$! $! &%& #$"
!
#!""!!!& " !#"
!""!!!""! # "!
44
S-P-F
Qty
1-800-328-5934
1-800-328-5934www.USPconnectors.com
www.USPconnectors.com
Holdowns
Engineered for high capacity with minimum deflection and low eccentricity.
HTT series Secures multi-ply studs or posts to mudsills or foundation. Nail fastening
makes for a convenient connection to studs or posts in cramped retrofit installations.
LTS series The LTS19 is designed for nail-on installation to 2x joists or studs, and
the LTS20B provides a nail or bolt fastening option. The LTS20B will accommodate
wood I-Joists if 10d x 11 2 nails are used instead of the specified 16d nails.
LTTI31 An open web joist tension tie designed for use with masonry or concrete
construction.
NEW
1 3/4
Holdowns
CL
D
W
LTTI31
6 1/4
L
3 3/4
2 1/2
1/4
CL
CL
transfer
plate
HTT16
(HTT22 similar)
HTT4
(HTT5 similar)
Steel Gauge
Typical HTT4
installation
Typical HTT45
installation
HTT45
Dimensions (in)
Fastener Schedule
USP
Stock No.
HTT45 (Min)
HTT4,
HTT5
10
-- --
2-1/2
HTT4
HTT4
12
-- --
HTT5
HTT5
12
-- --
HTT45 (Max)
HTT16
-- --
10
-- --
2-1/2
HTT22
-- --
10
-- --
2-1/2
21-1/2
LTTI31
4
LTS19
LTTI31
LTT19
18
16
3
3
3-3/4
1-3/4
31
22-1/4
LTS20B
LTT20B
12
20
DF-L
Lbs
5700
6710
7515
8505
4695
5690
6025
5625
7980
7390
5355
kN
25.35
29.85
33.43
37.83
20.89
25.33
26.81
25.02
35.50
32.88
23.82
S-P-F
Lbs
4905
5780
6465
7315
4025
4880
5165
4820
6840
6335
3800
kN
21.82
25.71
28.76
32.54
17.91
21.71
22.98
21.45
30.43
28.18
16.90
1-3/8
1-3/4
5/8
32
10d
5180
23.04
3680
16.37
2-5/8 1-3/8
3 1-1/2
3
2-1/2
1
1
5/8
3/4
3-3/4
3/4
18
8
10
10
2
10d x 1-1/2
10d
10d x 1-1/2
16d
1/2
2905
1245
1140
1145
1215
12.92
5.54
5.07
5.09
5.40
2440
1045
960
960
1020
10.85
4.65
4.27
4.27
4.54
1-1/2
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) 16d sinkers may be substituted for the specified 10d common nails with no load reduction.
3) The designer must specify anchor bolt type, length and embedment depth.
4) LTTI and LTS holdowns shall be installed tight to the sill plate.
5) NAILS:
New products or updated product information are designated in red font.
1-800-328-5934 www.USPconnectors.com
LTS20B
2,5
Strap
Anchor
Nail
3
Bolt
Spacing
L
D
CL
Qty Dia. (in) Qty
Type
(in)
10d
18
16d x 2-1/2
16
2 1-3/8 1-3/4
1
5/8
10d
26
16d x 2-1/2
10d x 1-1/2
10-7/16 2-3/4 1-3/8 1-3/4
1
5/8
20
10d
16d x 2-1/2
10d x 1-1/2
13-15/16 2-3/4 1-3/8 1-3/4
1
5/8
28
10d
16d x 2-1/2
15-5/8
2 1-3/8 1-3/4
1
5/8
18
10d
CL
1/4 transfer
plate
CL
LTS19
Hanger not shown
Typical LTS
Installation
USP2240-131
45
4 Min.
4,5,6
Dimensions (in)
Fastener Schedule
Holdowns
Qty
Dia.
(in)
TDL5
A24
12
5-3/16 2-1/4
1/2
TDL10
A311
12
9-3/4
1/2
2-1/4
1,2,3
Factored Resistance
Strap
Anchor Bolts
USP
Steel
Stock No. Ref. No. Gauge
Uplift 115%
DF-L
Qty
4
1
4
1
Type
16d
1/2
16d
1/2
Typical TDL5
interior installation
Lbs
975
1140
975
1140
kN
4.34
5.07
4.34
5.07
S-P-F
Lbs
840
980
840
980
kN
3.74
4.36
3.74
4.36
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake;
reduce for other load durations in accordance with the code.
2) Values given are based on the use of either nails or bolts; nail and bolt values cannot be combined.
!
4) Minimum nail embedment shall be 8 nail diameters (typ).
5) Designer must specify anchor bolt type, length, and embedment.
6) NAILS:
! !
D
W
TDL10
The coined dimples below the embedment line allow for increased concrete bonding. These holdowns retain
high uplift capacity even when installed at corners of foundation stemwalls. Ideal for use with built up 2x end posts.
LSTAD 14 gauge one-piece design allows labor effective installation without holdowns.
RJ after the model indicates LSTAD or STAD for rim joist applications as in STAD8RJ.
Rim joist models provide for a 17 clear span without the loss of strap nailing.
46
Typical TDL10
embedded interior
installation
Installation:
Use all specified fasteners. See Product Notes, page 10.
The TDL10 can be embedded into concrete. Minimum
embedment depth is 4 to achieve allowable loads.
Moisture barrier may be required.
Nailed
portion
W
12 Min.
rebar length
Install (1) #4
rebar in
2x embedment length, shear cone
Install (1)
#4 rebar in
shear cone
CS
12 Min.
rebar length
30 Min.
rebar length
CS
Edge distance
IE
Qty
Type
lE
24
16d
Sinker
3 21-5/8
LSTAD8RJ LSTHD8RJ 24
16d
Sinker
3 35-1/8
LSTAD8
LSTHD8
Min.
Stem
Wall
D CS (in) Unit
Lbs
6
kN
5 4-5/8
Lbs
8
kN
Lbs
6
kN
5 18-1/8
Lbs
8
kN
DF-L
S-P-F
2000 psi
2765
12.30
2765
12.30
2765
12.30
2765
12.30
2765
12.30
2765
12.30
2765
12.30
2765
12.30
2500 psi
lE
4000
17.79
4000
17.79
4000
17.79
4000
17.79
2765
12.30
2765
12.30
2765
12.30
2765
12.30
2765
12.30
2765
12.30
2765
12.30
2765
12.30
3000 psi
lE
4000
17.79
4000
17.79
4000
17.79
4000
17.79
2765
12.30
2765
12.30
2765
12.30
2765
12.30
2765
12.30
2765
12.30
2765
12.30
2765
12.30
2000 psi
lE
4000
17.79
4000
17.79
4000
17.79
4000
17.79
2320
10.32
2320
10.32
2320
10.32
2320
10.32
2320
10.32
2320
10.32
2320
10.32
2320
10.32
2500 psi
lE
3360
14.95
3360
14.95
3360
14.95
3360
14.95
2320
10.32
2320
10.32
2320
10.32
2320
10.32
2320
10.32
2320
10.32
2320
10.32
2320
10.32
3000 psi
lE
3360
14.95
3360
14.95
3360
14.95
3360
14.95
2320
10.32
2320
10.32
2320
10.32
2320
10.32
1) Factored resistances have been increased 15% for short-term load duration; no further increased is allowed.
2) 10d common (0.148" x 3" long) nails may be substituted with no load reduction.
4) The 115% values are short-term loads such as wind and earthquake.
5) RJ after the model indicates LSTADs for rim joist applications as in LSTAD8RJ.
6) Interpolate allowable loads for edge distances between those listed. Nail quantities may be reduced for
less than lE corner distance design loads- use the code allowable loads for fasteners in shear.
7) Where fewer fasteners are used in the structural wood member, reduce loads according to the code.
8) Minimum nail embedment shall be 8 nail diameters (typ).
9) NAILS: 16d Sinker nails are 0.148" dia. x 3-1/4" long.
2320
10.32
2320
10.32
2320
10.32
2320
10.32
lE
3360
14.95
3360
14.95
3360
14.95
3360
14.95
Holdowns
Ref. No.
Dimensions (in)
Fastener
2,3,8,9
Schedule
Typical STAD14RJ
corner rim joist installation
Typical STAD10
corner installation
Typical STAD10
edge installation
LSTAD8
USP
5
Stock No.
Edge distance
1/2 Min. from corner
L
CS
Dimensions (in.)
Fastener
1,2,10,11
Schedule
USP
Stock No
Ref. No.
Min
DF-L
Stemwall
Thickness
Steel
Ga.
Qty
Type
IE
(in.)
STAD8
STHD8
12
24
16d Sinker
21-5/8
STAD8RJ
STHD8RJ
12
24
16d Sinker
35-1/8
STAD10
STHD10
12
28
16d Sinker
21-5/8
10
STAD10RJ
STHD10RJ
12
28
16d Sinker
36
10
STAD14
STHD14
12
38
16d Sinker
32-1/8
14
STAD14RJ
STHD14RJ
12
38
16d Sinker
39-5/8
14
Edge
Distance 4,5
1
/2"
1.5 x IE
1
/2"
1.5 x IE
1
/2"
1.5 x IE
1
/2"
1.5 x IE
1
/2"
1.5 x IE
1
/2"
1.5 x IE
Lbs
3465
5660
3465
5660
3465
5660
3465
5660
7250
8035
7250
8035
kN
Lbs
kN
15.41
25.18
15.41
25.18
15.41
25.18
15.41
25.18
32.25
35.74
32.25
35.74
2980
4870
2980
4870
2980
4870
2980
4870
6235
6910
6235
6910
13.26
21.66
13.26
21.66
13.26
21.66
13.26
21.66
27.74
30.74
27.74
30.74
1-800-328-5934 www.USPconnectors.com
IE
S-P-F
STAD
W
L
CS
IE
D
STAD_RJ
USP2240-131
47
NEW
Installation:
Use all specified fasteners. See Product Notes, page 10.
Bending the strap horizontally 90 to facilitate wall placement may cause
concrete behind the embedded strap to break away at the top edge (spalling).
If the spall is 1 or less from the top edge of the concrete, no load reduction is
necessary. If the spall is between 1 and 4, the allowable load is 0.90 of the
published chart load.
When installing on lumber less than 312 wide, wood splitting may occur. To
reduce splitting, use 10d x 112 nails or fill every other hole with 16d common
nails. Reduce factored resistances in accordance with code requirements.
Straps are to be installed at the edge of concrete. Install prior to pour by nailing
to form. Drive temporary nails through lowest two nail holes into form. Concrete
level should reach embedment line; minimum embedment depths are listed in
chart.
Do not rely on these straps to secure concrete sections together between cold
joints; take other measures to transfer the load. If there is a cold joint between slab
and foundation, the minimum embedment must be made into the foundation.
Fastening opportunities may be reduced because the slab pour level may be
higher than some nail holes. Using fewer fasteners will reduce factored
resistances. Reduce factored resistance by the code capacity for each fastener
not installed.
Factored resistances based on a minimum concrete compressive strength of
2,500 psi at 28 days, with one #4 horizontal rebar in the shear cone. Rebar should
be a minimum length of 2x embedment depth plus 12 (see chart for exceptions in
corner installations).
Where fewer fasteners are used in the structural wood member, reduce loads
according to the code.
There may be an increase in the amount of deflection if the strap is installed on
the outside of the sheathing, versus directly to the framing members.
Strap may be bent one complete cycle to aid installation.
2x embedment
length + 12 Min.
rebar length
Install (1)
#4 rebar in
shear cone
Holdowns
Typical HPAHD22
single pour edge
installation
Install (1) #4
rebar in
shear cone
12 Min.
rebar
length
30 Min.
rebar length
1/2 Min.
from corner
Typical HPAHD22
single pour corner and
endwall installation
Nailed
portion
H1
H1
Embedment
line
(1) #4 rebar
in shear
cone
H1
13 1/2
Embedment
line
lE
LE
lE
lE
1/2 min.
HPAHD
48
PAHD42
1-800-328-5934
1-800-328-5934www.USPconnectors.com
www.USPconnectors.com
from corner
Typical HPAHD22
single pour rim joist
installation
Schedule
USP
Stock No
Ref.
No.
Steel
Ga. Qty
Type
HPAHD22
-- --
10
23
16d
PAHD42
-- --
12
15
16d
Dimensions (in.)
Min
Stemwall
Edge
Thickness
4,5
9,10
Distance
W
L
IE
D
(in.)
Concrete
Uncracked
1
/2"
Cracked
6
2-1/16 24-3/4 9-1/2 4-1/8
Uncracked
1.5 x IE
Cracked
Uncracked
1
/2"
Cracked
2-1/16 16-5/8 8 5-3/4
6
Uncracked
1.5 x IE
Cracked
DF-L
S-P-F
Lbs
kN
4780
3345
5345
3745
2555
1785
4675
3275
21.262
14.879
23.776
16.659
11.365
7.9401
20.795
14.568
Lbs
4330
3345
4330
3745
2555
1785
3495
3275
kN
19.261
14.879
19.261
16.659
11.365
7.9401
15.547
14.568
1) A 16d Common nail has a diameter of 0.162 inch and a length of 3-1/2 inches.
2) Predrilled holes are not required
3) Minimum nail embedment shall be 8 nail diameters (typ).
4) An edge distance of 1/2" implies that the distance from the corner of the wall to the edge of the strap is no less than 1/2".
5) An edge distance of 1.5 x IE implies that the minimum distance from the corner of the wall to the centerline of the strap is
no less than 1.5 times the embedment depth.
6) For edge distances between 1/2" and 1.5 x lE calculate loads using straight line interpolation.
7) Minimum anchor spacing for full capacity is 2 x lE. For spacing less than that reduce capacity proportionally.
8) The allowable loads are based on lumber with a specific gravity of 0.49 for DF-L and 0.42 for S-P-F with a moisture content of 19% or less.
9) Minimum concrete strength f'c = 2500 psi
10) Minimum 1-#4 rebar shall be installed in the shear cone
New products or updated product information are designated in red font.
Holdowns
Double
2 X 10
rim joist
NEW
Materials: 12 gauge
Finish: G90 galvanizing
Finish: TA51 and TA71 are available in Triple Zinc. To order
add TZ to stock number, as in TA51-TZ
Codes: Load values are derived from data submitted to
various North American building code evaluators.
6 Min.
Double
2 X 10
rim joist
Typical TA
installation
Installation:
Use all specified fasteners. See Product Notes, page 10.
Factored resistances are based on either nail fastening or bolt fastening; nail and bolt values
cannot be combined.
Install by inserting product into footings wet concrete. All models require a 6 embedment into
concrete foundations. Courses of concrete block must be laid over connector. Notch mudsill at
connector locations. Wrap strap over rim joist and fasten.
Do not rely on these straps to secure concrete sections together between cold joints; take other
measures to transfer the load. If there is a cold joint between block and foundation, the minimum
embedment must be made into the foundation.
Based on product embedment the exposed number of fastener holes may be reduced. Using
fewer fasteners will reduce allowable loads. Reduce factored resistance by the code prescribed
factored resistance per fastener, for each fastener not installed.
Factored resistances are based on a minimum concrete compressive strength of 2,000 psi at
28 days.
Dimensions (in)
Fastener
1,3,4,5
Schedule
W
L1
2 1/4
L1
USP
Ref.
Stock No. No.
Typical TA
stud to foundation
installation
Qty
Type
2 x 10
Uplift2
DF-L
Fastener
1,3,4,5
Schedule
S-P-F Qty
Type
2 x 12
Uplift2
DF-L
2 x 14
Uplift2
Fastener
1,3,4,5
Schedule
S-P-F Qty
Type
Fastener
1,3,4,5
Schedule
Type
Uplift2
DF-L S-P-F
Bolt Uplift Values & Schedules for Rim Joist Sizes Below
TA51
TA71
PA51
48-1/4
2-1/16
22-1/8 2
PA68
68-1/4
TA51
TA71
PA51
48-1/4
2-1/16
22-1/8 8
0
PA68
68-1/4
1/2
3335
2615
1/2
2615
2615
2615
14
0
3635
16
0
3635
1/2
1/2
Nail Uplift Values & Schedules for Rim Joist Sizes Below
1965
0
1965
'$,.$-+*'*2, !#*!%"'!+,$'(*(&!-$*,'*!&
,'**+!+,&+ .&!&*+
'*+ '*,,*%$'++- +/!&&*, )-#&'-*, *!&*+!+$$'/
!&!%-%&!$%%&,+ $$&!$!%,*+,1(
,'*($!,+!+,&'*'$,'&&,!'&++'&-((*%'+,+,&*
*'%,'('*!%'*
5) Nails:
0
&!$+*
!%,*1
2$'&
/(*'-,+'*-(,(*'-,!&'*%,!'&*+!&,!&red font.
1-800-328-5934 www.USPconnectors.com
TA
USP2240-131
49
PAI series For wood I-Joist applications. An expanded 3 on-centre nail spacing reduces splitting along
I-Joist flange.
Materials: 12 gauge
Finish: G90 galvanizing
Options: PA18, PA23 and PA28 are available in Triple Zinc.
To order, add TZ to end of stock number, as in PA18-TZ.
Codes: Load values are derived from data submitted to various
North American building code evaluators.
Concrete
Masonry
Holdowns
50
Minimum
Embedment
PA18
PA18
18-1/2
PA23
PA23
23-3/4
PA28
PA28
29
PA35
PA35
35
PAI18
PAI23
PAI28
PAI35
PAI18
PAI23
PAI28
PAI35
18-1/2
23-1/2
28-1/2
35-1/2
4
4
4
4
6
6
6
6
PA18
PA18
18-1/2
PA23
PA23
23-3/4
PA28
PA28
29
PA35
PA35
35
PAI18
PAI23
PAI28
PAI35
PAI18
PAI23
PAI28
PAI35
18-1/2
23-1/2
28-1/2
35-1/2
4
4
4
4
6
6
6
6
PA18
PA18
18-1/2
PA23
PA23
23-3/4
PA28
PA28
29
USP
Stock No.
Ref. No.
L
(in)
PA35
PA35
35
PAI18
PAI23
PAI28
PAI35
PAI18
PAI23
PAI28
PAI35
18-1/2
23-1/2
28-1/2
35-1/2
4
4
4
4
6
6
6
6
Fastener
4,5,6,8
Schedule
Min
7
Qty
12
2
15
3
15
4
15
4
12
18
24
26
12
2
15
3
15
4
15
4
12
18
24
26
12
2
15
3
15
4
15
4
12
18
24
26
Type
Lbs
kN
Maximum Capacity
16d
3200 14.23
1/2
2340 10.41
16d
4175 18.57
1/2
3380 15.04
16d
4175 18.57
1/2
4185 18.62
16d
4175 18.57
1/2
4185 18.62
10d x 1-1/2 2565 11.41
10d x 1-1/2 3845 17.10
10d x 1-1/2 4595 20.44
10d x 1-1/2 4595 20.44
2x & 3x Ledger
16d
3200 14.23
1/2
2340 10.41
16d
4175 18.57
1/2
3380 15.04
16d
4175 18.57
1/2
4185 18.62
16d
4175 18.57
1/2
4185 18.62
10d x 1-1/2 2565 11.41
10d x 1-1/2 3635 16.17
10d x 1-1/2 4595 20.44
10d x 1-1/2 4595 20.44
4x Ledger
16d
3200 14.23
1/2
2340 10.41
16d
4175 18.57
1/2
3380 15.04
16d
4175 18.57
1/2
4185 18.62
16d
4175 18.57
1/2
4185 18.62
10d x 1-1/2 2355 10.48
10d x 1-1/2 3205 14.26
10d x 1-1/2 4595 20.44
10d x 1-1/2 4595 20.44
Typical PA holdown
installation
1,3
S-P-F
Masonry
Concrete
Masonry
Lbs
kN
Lbs
kN
Lbs
kN
3200
2340
3770
3380
3770
3770
3770
3770
2565
3770
3770
3770
14.23
10.41
16.77
15.04
16.77
16.77
16.77
16.77
11.41
16.77
16.77
16.77
2685
1965
3505
2840
3505
3515
3505
3515
2155
3230
3860
3860
11.94
8.74
15.59
12.63
15.59
15.64
15.59
15.64
9.59
14.37
17.17
17.17
2685
1965
3165
2840
3165
3165
3165
3165
2155
3165
3165
3165
11.94
8.74
14.08
12.63
14.08
14.08
14.08
14.08
9.59
14.08
14.08
14.08
3200
2340
3770
3380
3770
3770
3770
3770
1925
3635
3770
3770
14.23
10.41
16.77
15.04
16.77
16.77
16.77
16.77
8.56
16.17
16.77
16.77
2685
1965
3505
2840
3505
3515
3505
3515
2155
3050
3860
3860
11.94
8.74
15.59
12.63
15.59
15.64
15.59
15.64
9.59
13.57
17.17
17.17
2685
1965
3165
2840
3165
3165
3165
3165
1615
3050
3165
3165
11.94
8.74
14.08
12.63
14.08
14.08
14.08
14.08
7.18
13.57
14.08
14.08
3200
2340
3770
3380
3770
3770
3770
3770
1925
3205
3770
3770
14.23
10.41
16.77
15.04
16.77
16.77
16.77
16.77
8.56
14.26
16.77
16.77
2685
1965
3505
2840
3505
3515
3505
3515
1975
2690
3860
3860
11.94
8.74
15.59
12.63
15.59
15.64
15.59
15.64
8.79
11.97
17.17
17.17
2685
1965
3165
2840
3165
3165
3165
3165
1615
2690
3165
3165
11.94
8.74
14.08
12.63
14.08
14.08
14.08
14.08
7.18
11.97
14.08
14.08
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
"
3) Values are based on the use of either nails or bolts; nail and bolt values cannot be combined.
4) 16d sinkers or 10d common nails may be substituted for the specified 16d common nails at 0.85 of the table loads.
5) Minimum nail embedment shall be 8 nail diameters (typ).
6) For alternate nail schedule and load values consult USP.
7) Minimum quantity of fasteners to be installed. Product may have additional fastener holes not needed to meet published allowable load of product.
8) NAILS: !
"
!"
1-800-328-5934
1-800-328-5934www.USPconnectors.com
www.USPconnectors.com
4 Min. concrete
20 Min. concrete block
edge distance
#4 rebar
min.
4
Typical PAI
I-Joist purlin
face installation
Ledger
2 1/16
PAI
2 1/16
1 1/2
4 1/2
L
PA
Installation:
Typical PA purlin
Use all specified fasteners. See Product Notes, page 10.
installation
Minimum concrete strength is 2,000 psi.
The factored resistance for bolts are based on parallel to grain loading with a 3 minimum
member thickness. Reduce load per code requirements when minimum member thickness is
not achieved.
Minimum concrete edge distance is 4 for PA & PAI series.
Minimum concrete block edge distance is 20.
Designer may specify alternate fastening schedules. Refer to Nail Specification Table on
page 14 for nail shear values. Load values shall not exceed published factored resistance.
No anchor bolts are needed for achieving efficient stress transfer from framing to concrete
walls or foundations.
PA
PA(E)
PAU
WAS Series
Wood-to-concrete post base with 1 stand-off installs in wet
concrete.
WE Series
Wood-to-concrete post base installs in wet concrete.
WE
WAS
EBG/EPB
APB
EPBH
RSCH
CBSQ
KCBQ
CBE
EPCM
PCM
BC
PB
PBES
PBS
PBC Series
Light-capacity corner post to beam connector.
CBE Series
Light capacity column base bolts or nails to column.
PBC
CPB
KCCQ
1-800-328-5934 www.USPconnectors.com
KECCQ
USP2240-131
51
NEW
SIZE
PA(E) 2-sided post anchors with high uplift and bearing capacity.
PA High capacity utilizing 4-sided design.
Typical PA
installation
PAU
cross-section
Stand-off
plate
Washer
H
2
Base
2 3/4
L
PA
Steel Gauge
3,4
Dimensions (in)
4x4
4x4
Rough
4x4
4x4
4x6
4x6
Rough
4x6
4x6
6x6
6x6
Rough
6x6
52
USP
Stock No.
PA44
PA44R
PA44E
PA44E-GC
PAU44
PA46
PA46R
PA46E
PA46E-GC
PAU46
PA66
PA66R
PA66E
PA66E-GC
Ref. No.
-- --- --- --- -ABU44
-- --- --
Stand-off
Base Plate
W
18
12
3-9/16
18
12
4-1/16
DF-L (Lbs)
Uplift1
S-P-F (kN)
Uplift1
Uplift1
L
3-1/2
Qty
1
Dia.
1/2
Qty
8
Type
16d
Qty
-- --
3-1/2
1/2
12
16d
-- --
-- --
8410
720
-- --
37.41
3.20
-- --- -1/2
-- --
11095
11095
11095
10290
1655
1655
4770
955
-- --- -3790
-- --
49.35
49.35
49.35
45.77
-- --
10290
955
-- --
45.77
4.25
1025
1025
4770
785
-- --- -3790
-- --
16
3-9/16
3-1/2
3-1/2
1/2
12
18
16
12
3-9/16 5-7/16
3-9/16 3-1/2
3
5-1/2
1
1
5/8
1/2
18
14
10
4-1/16
3-1/2
1/2
18
12
3-9/16
3-1/2
5-1/2
5/8
10
18
12
12
3-9/16
5-9/16
6
3-1/2
5
5-1/2
1
1
-- --
18
12
6-1/16
3-1/4
6-1/16
5-1/2
S-P-F (Lbs)
H
2-1/8
18
12
Uplift1
Bolts
6
16d
-- -6 N16C-GC -- -12
16d
2
14
16d
-- --
14
DF-L (kN)
Bearing Nails Bolts Bearing Nails Bolts Bearing Nails Bolts Bearing Nails Bolts
Dia. 100% 115% 115% 100% 115% 115% 100% 115% 115% 100% 115% 115%
-- -8410
720
-- -- 37.41 3.20 -- -5970
510
-- -- 26.56 2.27 -- --
ABA46
-- -ABU46
-- --
ABA66
-- --
Post
Nails
PAU
Factored Resistance
Fastener Schedule
Anchor Bolt
Post/
Column
Size
Installation:
Use all specified fasteners. Install with supplied washer.
See Product Notes, page 10.
Anchor bolts and nails are not furnished.
Not recommended for fence posts or other
unrestrained (not fixed or fastened at top) applications.
These anchors are not designed to resist overturning
(moment) loads.
Anchor bolt installation position specified diameter
anchor bolt at desired location with minimum 4 embedment
into 2000 psi concrete. A minimum 2 edge distance is
required to achieve factored resistance.
For hardened concrete or retrofit installations
use 5/8 diameter threaded rod with epoxy adhesive,
follow installation instructions.
Typical PA44E
installation
3-1/2
5-1/2
16d
-- --
-- --
-- --
5970
510
-- --
26.56
2.27
7875
7875
7875
7305
1175
1175
3385
680
-- --- -2690
-- --
35.03
35.03
35.03
32.49
-- --
7305
680
-- --
32.49
3.02
17110
17110
16065
8085
880
880
3385
555
-- --- -2690
-- --
76.11
76.11
71.46
35.96
-- --
5/8
1/2
8
16d
-- -8 N16C-GC
12
16d
2
16
16d
-- --
1/2
-- --
19895
19895
22625
11385
1/2
16
-- --
11385
785
-- --
50.64
3.49
-- --
8085
555
-- --
35.96
2.47
-- --
5/8
8
8
-- --
26215
26215
1770
1770
-- --- --
116.61
116.61
7.87
7.87
-- --- --
18615
18615
1255
1255
-- --- --
82.81
82.81
5.58
5.58
-- --- --
18615
1255
-- --
82.81
5.58
-- --
18615
9650
2820
3775
2690
-- --
82.81
42.93
12.54 11.97
16.79 -- --
9650
3775
-- --
42.93
16.79
16d
-- --
16d
-- -N16C-GC
-- --
6x6
PA66ER-TZ ABA66R
14
12
6
3-1/4 5-1/2 1
5/8
8
16d
-- -- -- -- 26215 1770 -- -- 116.61 7.87 -- -Rough
6x6
PAU66
ABU66
10
12
5-1/2
6
5
1
5/8
12
16d
2
1/2 26215 3975 3790 116.61 17.68 16.86
8x8
PAU88
ABU88
12
12
7-1/2 7-3/16 7-1/16 2
5/8
14
16d
-- -- -- -- 13595 5320 -- -- 60.48 23.67 -- -8x8
PAU88R
ABU88R
12
12
8-1/16 6-15/16 7-1/16 2
5/8
14
16d
-- -- -- -- 13595 5320 -- -- 60.48 23.67 -- -Rough
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) Factored resistances are based on the use of either nails or bolts; nail and bolt values cannot be combined.
3) Minimum nail embedment shall be 8 nail diameters (typ).
4) NAILS:
New products or updated product information are designated in red font.
1-800-328-5934 www.USPconnectors.com
-- --
Uplift
2 Min.
edge distance
USP
Stock No. Ref. No.
WE44
PB44
Base
12
Strap
12
Dimensions (in)
W1
W2
-- --
H1
H2
WE44R
PB44R
12
12
-- --
WE46
PB46
12
12
-- --
Rough
WE46R
Rough
W1
H1
H1
11 3/16
WAS
WE
Qty
Type
12
16d
12
16d
12
16d
12
12
-- --
12
16d
WE66
PB66
12
12
-- --
12
16d
WE66R
PB66R
12
12
-- --
12
16d
14
16d
WAS44
PBS44A
16
14
2
14
16d
14
16d
WAS46
WAS66
PBS46
PBS66
12
12
14
12
W2
H2
H2
-- --
W1
Rough
Typical WAS
installation
Typical WE
installation
Fastener
Schedule3,5,6
2
1 Stand-off
plate
2 Min.
edge
distance
Factored Resistance4,5
Wood
Species
DF-L
S-P-F
DF-L
S-P-F
DF-L
S-P-F
DF-L
S-P-F
DF-L
S-P-F
DF-L
S-P-F
DF-L
S-P-F
DF-L
S-P-F
DF-L
S-P-F
DF-L
S-P-F
DF-L
S-P-F
DF-L
S-P-F
DF-L
S-P-F
DF-L
S-P-F
Bearing 100%
F1 (115%)1
Lbs
-- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- -9755
8390
9755
8390
19895
17110
19895
17110
23045
19820
23045
19820
Lbs
1415
1215
1135
975
1470
1265
1415
1215
1135
975
1470
1265
-- --- --- --- -1750
1505
1760
1515
1750
1505
1850
1590
2615
2250
2695
2320
kN
-- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- -43.39
37.32
43.39
37.32
88.50
76.11
88.50
76.11
102.51
88.17
102.51
88.17
kN
6.29
5.40
5.05
4.34
6.54
5.63
6.29
5.40
5.05
4.34
6.54
5.63
-- --- --- --- -7.78
6.69
7.83
6.74
7.78
6.69
8.23
7.07
11.63
10.01
11.99
10.32
F2 (115%)1
Lbs
1470
1265
1270
1090
1415
1215
1470
1265
1270
1090
1415
1215
2790
2400
2790
2400
1620
1395
1620
1395
1620
1395
1620
1395
1915
1645
1915
1645
kN
6.54
5.63
5.65
4.85
6.29
5.40
6.54
5.63
5.65
4.85
6.29
5.40
12.41
10.68
12.41
10.68
7.21
6.21
7.21
6.21
7.21
6.21
7.21
6.21
8.52
7.32
8.52
7.32
Uplift (115%)1
Lbs
1750
1505
1780
1530
1750
1505
1750
1505
1780
1530
1750
1505
2615
2250
2615
2250
3235
2780
3235
2780
3235
2780
3235
2780
3420
2940
4530
3895
kN
7.78
6.69
7.92
6.81
7.78
6.69
7.78
6.69
7.92
6.81
7.78
6.69
11.63
10.01
11.63
10.01
14.39
12.37
14.39
12.37
14.39
12.37
14.39
12.37
15.21
13.08
20.15
17.33
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) H2 is mimimum embedment length of anchor into concrete.
3) Minimum nail embedment shall be 8 nail diameters (typ).
4) Minimum concrete compressive strength shall be 2,000 psi at 28 days.
5) Factored resistances are based on the use of either nails or bolts; nail and bolt values cannot be combined.
6) NAILS:
1-800-328-5934 www.USPconnectors.com
USP2240-131
Steel Gauge
F2
F1
53
NEWS
SIZE
These post bases allow installers to pre-align posts and pre-set post
heights above concrete floors or footings. By eliminating
post-to-concrete contact, moisture damage is reduced. Elevated
post bases are ideal for building carports, decks or porches. All
series feature convenient nail fastening to post.
Dimensions (in)
Post
Size
USP
Stock No.
4x4
EPBH44
4x6
Rough
6x6
6x6
Rough
EPBH46R
Fastener
3,4
Schedule
RCPS46HDG
H1
S-P-F
F21,2
F21,2
Uplift2
H1
H2
Qty
Type
Unit
100%
115%
115%
115%
100%
115%
115%
115%
3-1/2
3-3/8
2-3/4
16d HDG
-- --
-- --
-- --
-- --
-- --
-- --
-- --
-- --
-- --
4-1/8
5-3/8
16d HDG
-- --
-- --
-- --
-- --
-- --
-- --
-- --
-- --
-- --
5-1/2
5-3/8
16d HDG
-- --
-- --
-- --
-- --
-- --
-- --
-- --
-- --
-- --
6-1/8
5-3/8
16d HDG
-- --
-- --
-- --
-- --
-- --
-- --
-- --
-- --
-- --
3-9/16
16d
3-9/16
12
16d
5-9/16
3-3/16
12
16d
3-9/16
2-3/4
2-3/8
7-1/2
16d HDG
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
3045
13.55
3045
13.55
4665
20.75
2485
11.05
1115
4.96
2270
10.10
2270
10.10
1100
4.89
1075
4.78
1695
7.54
1695
7.54
1180
5.25
1140
5.07
1560
6.94
1560
6.94
1085
4.83
2620
11.65
2620
11.65
4010
17.84
2135
9.50
960
4.27
1950
8.67
1950
8.67
945
4.20
925
4.11
1460
6.49
1460
6.49
1015
4.52
980
4.36
1340
5.96
1340
5.96
935
4.16
EPB4608
6x6
EPB6608
4x4
EBG44-TZ
EPB44A
Typical EPB
installation
EPBH
2
RCPS5.5HDG
4x6
3" Min.
edge
distance
H2
RCPS6HDG
EPB44,
EPB44-12
EPB46,
EPB46-12
EPB66,
EPB66-12
Bearing
F2
EPBH66
EPB4408
Uplift
F1
EPBH66R
4x4
Typical EBG44-TZ
installation
DF-L
Bearing F11,2
Ref. No.
EPB44PHDG,
RCPS3.5HDG
Typical EPBH
installation
H1
H2
EPB/EBG
similar
1) Lateral loads (F1 and F2) are for conditions where pipe extends no more than 1" above the concrete surface.
2) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for
other load durations in accordance with the code.
3) Minimum nail embedment shall be 8 nail diameters (typ).
4) NAILS:
New products or updated product information are designated in red font.
Allows height adjustments of post after installation. A maximum height adjustment of 4 can be achieved
with this product. Adjustments may be required if original installation is not exact, if there is a greater slope
on a deck than estimated, or if there is heaving or sinking of the post beyond the initial installation. Embed
in concrete a minimum of 6. Useful for reducing moisture damage.
Materials: 16 gauge tube; 12 gauge steel U-bracket
Finish: Hot-dip galvanized
Installation:
Use all specified fasteners. See Product Notes, page 10.
Not recommended for fence posts or other unrestrained
(not fixed or fastened at top) applications. These anchors are not
designed to resist overturning (moment) loads
USP
Post Size Stock No. Ref. No.
4x4
6x6
54
APB44
APB66
-- --- --
H1
H2
Qty
Type
4
4
16d HDG
16d HDG
H1
H2
Fastener Schedule1,2
Dimensions (in)
W
6 3/8
APB
1-800-328-5934 www.USPconnectors.com
Typical APB
installation
1 Max.
elevation
NEW
SIZE
F1
Post
Size
4x4
4 x 4 Rough
4x6
4 x 6 Rough
6x6
6 x 6 Rough
8x8
Steel
USP
Stock No. Ref. No. Gauge
BC40,
D44-TZ
18
BC40Z
RSCH44
-- -12
D44R
BC40R
18
D46
BC460
18
D46R-TZ
-- -18
D66
BC60
18
RSCH66
-- -12
D66R
BC60R
18
D88
BC80
18
Qty
16d HDG
16d HDG
16d HDG
16d
16d
16d HDG
16d
16d HDG
16d
16d
1
4
5
5
5
1
5
5
-- -1/2"
16d
-- -16d
-- -16d HDG -- -16d
-- --- -1/2"
16d
-- -16d
-- --
D
RSCH
Factored Resistance1 (115%)
Beam
Nails
Typical D
installation
Fastener Schedule2,3
Post
Qty
Nails
Uplift
Installation:
Use all specified fasteners. See Product Notes, page 10.
Not recommended for fence posts or other unrestrained (not fixed or
fastened at top) applications. These anchors are not designed to resist
overturning (moment) loads.
While D series post anchors offer some lateral and uplift resistance, they
are not recommended as a primary means of anchorage for posts in
railings. They may be used only for intermediate posts between fully
anchored corner / end posts in rail systems.
Dimensions (in)
F2
Bolts
-- --
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
F1
F2 Uplift F1
F2 Uplift F1
F2 Uplift F1
F2 Uplift
1920 2065 1345 8.54 9.19 5.98 1365 1465 955
-- -1920
1920
1920
1920
-- -1920
1920
-- -6.07
6.07
6.07
6.07
-- -6.07
6.07
-- -2065
2065
2065
2065
-- -2065
2065
-- -1345
1345
1345
1345
-- -1345
1345
-- -8.54
8.54
8.54
8.54
-- -8.54
8.54
-- -9.19
9.19
9.19
9.19
-- -9.19
9.19
-- -5.98
5.98
5.98
5.98
-- -5.98
5.98
-- -1365
1365
1365
1365
-- -1365
1365
-- -1465
1465
1465
1465
-- -1465
1465
-- -955
955
955
955
-- -955
955
-- -6.52
6.52
6.52
6.52
-- -6.52
6.52
-- -4.25
4.25
4.25
4.25
-- -4.25
4.25
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) NAILS:
New products or updated product information are designated in red font.
1
3 Min. edge
distance
These column bases install using USPs WS2-HDG Wood Screws, reducing installation time
and cost. Designed for high uplift in high wind or seismic applications. Includes a stand-off
plate to protect the wood from ground contact moisture.
Materials: See chart
Finish: G-185 galvanizing
Options: CBSQ44, CBSQ46, and CBSQ66 are available in Hot-dip galvanized.
To order, add HDG to stock number, as in CBSQ44-HDG.
Typical CBSQ44-TZ
installation
L
Installation:
Use all specified fasteners. See Product Notes, page 10.
WS2-HDG Wood Screws, 1/4 dia. x 2 long, are supplied with CBSQ Bases.
All models require a minimum edge distance of 3.
Embed the column base until the concrete surface meets the bottom edge of the stand-off
plate.
Not recommended for fence posts or other unrestrained (not fixed or fastened at top)
applications. These bases are not designed to resist overturning (moment) loads.
Steel Gauge
Column
Size
USP
Stock No.
Ref. No.
Dimensions (in)
standoff
W2
7 3/16
W1
CBSQ44-TZ
Factored Resistance
Fastener
Schedule2,3
DF-L
S-P-F
Bearing 100%
Uplift 115%1
Bearing 100%
Uplift 115%1
Strap
Base
W1
W2
Qty
Type
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
3-1/2
4x4
CBSQ44-TZ
CBSQ44-SDS2
10
16
3-9/16
8-3/4
2-1/4
14
WS2-HDG
9725
43.26
9895
44.02
8365
37.21
8510
37.86
4x6
6x6
CBSQ46-TZ
CBSQ66-TZ
CBSQ46-SDS2
CBSQ66-SDS2
10
10
12
12
2-1/4
3
14
14
WS2-HDG
WS2-HDG
19895
23045
88.50
102.51
9895
9895
44.02
44.02
17110
19820
76.11
88.17
8510
8510
37.86
37.86
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
! !
3) Concrete compressive strength shall be 2,000 psi or greater at 28 days.
1-800-328-5934 www.USPconnectors.com
USP2240-131
55
3 3/16
W2
W1
Installation:
Use all specified fasteners. See Product Notes, page 10.
WS2 Wood Screws, 1/4 dia. x 2 long, are supplied with KCBQ
Column Bases.
Not recommended for fence posts or other unrestrained (not
fixed or fastened at top) applications. These bases are not
designed to resist overturning (moment) loads.
All models require a minimum edge distance of 3.
Bolted models feature diamond holes for temporary nail fastening
to facilitate drilling and bolting.
Embed column base with bottom of base plate flush to concrete.
Typical CBE
installation
CBE
L
3 Min.
edge distance
W2
W1
8
KCBQ66
Fastener
Factored Uplift Resistance (115%)1,5
Schedule2,3,4,5,6,7
DF-L
S-P-F
Dimensions (in)
Column
Size
USP
Stock No.
Steel
Gauge
W1
W2
CBE44
LCB44
12
3-9/16
3-1/2
7-1/2
KCBQ44
CB44,
CBQ44-SDS2
10
3-9/16
3-1/2
8-3/4
4x4
CBE46
4x6
Ref. No.
LCB46
4x8
6x4
KCBQ48
KCBQ64
CB46,
CBQ46-SDS2
CB48
-- --
6x6
CBE66
LCB66
KCBQ46
6x6
KCBQ66
6x8
7-1/8 x 3-1/2
7-1/8 x 5-1/2
7-1/8 x 7-1/8
8x6
8x8
10 x 10
10 x 12
12 x 12
KCBQ68
KCBQ71-4
KCBQ71-6
KCBQ71-7
KCBQ86
KCBQ88
KCBQ1010
KCBQ1012
KCBQ1212
CB66,
CBQ66-SDS2
CB68
CB71/8-4
CB71/8-6
CB71/8-7
CB86
CB88
CB1010
CB1012
CB1212
Qty
2
12
Type
1/2
16d
Lbs
6305
4060
kN
28.05
18.06
Lbs
5420
3490
kN
24.11
15.52
2-1/4
14
WS2
14345
63.81
10605
47.17
1/2
16d
6295
4060
28.00
18.06
5415
3490
24.09
15.52
12
3-9/16
5-1/2
7-1/2
2
12
10
3-9/16
5-1/2
8-3/4
2-1/4
14
WS2
14345
63.81
10605
47.17
10
10
3-9/16
5-1/2
7-1/2
3-1/2
8-3/4
8-3/4
2-1/4
2-1/4
12
5-1/2
5-1/2
7-1/2
14
14
2
12
WS2
WS2
1/2
16d
14345
14345
6280
4060
63.81
63.81
27.93
18.06
10605
10605
5400
3490
47.17
47.17
24.02
15.52
10
5-1/2
5-1/2
8-3/4
2-1/4
14
WS2
14345
63.81
10605
47.17
10
10
10
10
10
10
10
10
10
2-1/4
2-1/4
2-1/4
2-1/4
2-1/4
2-1/4
2-1/4
2-1/4
2-1/4
14
14
14
14
14
14
14
14
14
WS2
WS2
WS2
WS2
WS2
WS2
WS2
WS2
WS2
14345
14345
14345
14345
14345
14345
14345
14345
14345
63.81
63.81
63.81
63.81
63.81
63.81
63.81
63.81
63.81
10605
10605
10605
10605
10605
10605
10605
10605
10605
47.17
47.17
47.17
47.17
47.17
47.17
47.17
47.17
47.17
5-1/8
CB5-4.5,
KCBQ5
10
5-1/4 Spec. 8-3/4 2-1/4
14
WS2
14345 63.81 10605 47.17
glulam
CB5-6
6-3/4
CB7-6, CB7-7.5,
KCBQ7
10
6-7/8 Spec. 8-3/4 2-1/4
14
WS2
14345 63.81 10605 47.17
glulam
CB7-9, CB7-10.5
8-3/4
CB9-6, CB9-7.5,
KCBQ9
10
8-7/8 Spec. 8-3/4 2-1/4
14
WS2
14345 63.81 10605 47.17
glulam
CB9-9, CB9-10.5
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) Concrete compressive strength shall be 2,000 psi or greater at 28 days.
!
#"# !
5) Factored resistances are based on the use of either nails or bolts; nail and bolt values cannot be combined.
6) Bolts shall conform to ASTM A 307 or better.
7) NAILS:#" #
56
1-800-328-5934 www.USPconnectors.com
Typical KCBQ66
installation
H1
L2
F2
Uplift
W1
3 3/4
L1
F1
W2
PCM
Installation:
Use all specified fasteners. See Product Notes, page 10.
PCM 16 gauge post caps should not be substituted for PCM 12
gauge post caps unless approved by the Engineer of Record.
Typical PCM46
installation
W1
L2
H1
1,2
Fastener Schedule
USP
Series
Ref.
Series
Post
Steel
Gauge
Beam
Qty
Type
Qty
PCM_16
PC_16
16
8
16d
12
PCM
PC
12
8
16d
12
EPCM_16 EPC_16
16
8
16d
8
EPCM
EPC
12
8
16d
8
1) Minimum nail embedment shall be 8 nail diameters (typ).
2) NAILS:
PCM86
PCM8816
PCM88
EPCM4416
EPCM44
EPCM46
EPCM4616
EPCM4816
EPCM48
EPCM6416
EPCM64
EPCM6616
EPCM66
EPCM6816
EPCM68
EPCM8416
EPCM84
EPCM8616
EPCM86
EPCM8816
EPCM88
PC44
PC46
PC48
PC64
PC66
PC68
PC84
PC86
PC88
EPC44
EPC46
EPC48
EPC64
EPC66
EPC68
EPC84
Qty
Beam Post
W1
W2
H1
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
L1
L2
F1
F2
Centre Column Caps
11
11
11
11
11
11
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
Uplift
F1
F2
Uplift
F1
F2
Uplift
F1
F2
Uplift
1600
1600
1600
1140
1140
1140
1160
1860
1160
1860
1160
1860
1860
1160
1860
1160
8.12
8.12
8.12
8.12
8.12
6.81
6.81
6.81
8.12
8.12
8.12
8.12
8.12
1840
1840
1840
1840
1840
1610
1610
1610
,
1860
1840
,
,
1160
8.12
8.12
,
,
End Column Caps
1860
1840
1610
1610
1610
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
Steel
Gauge
1600
1600
1600
1140
1140
1140
1160
1860
1160
1860
1160
1860
1860
1160
1860
1160
8.12
8.12
8.12
8.12
8.12
6.81
6.81
6.81
8.12
8.12
8.12
8.12
8.12
EPC86
,
1860
,
,
1160
8.12
8.12
EPC88
,
,
1860
PCM4416
PCM44
PCM46
PCM4616
PCM4816
PCM48
PCM6416
PCM64
PCM6616
PCM66
PCM6816
PCM68
PCM8416
PCM84
PCM8616
Ref.
Series
Typical EPCM
installation
EPCM
DF-L (Lbs)
Ref. No.
USP
Series
W2
L1
Dimensions (in)
USP
Stock No.
Fas
3 3/4
Type
16d
16d
16d
16d
1-800-328-5934 www.USPconnectors.com
USP2240-131
57
PB Two-piece design.
PBES &PBS Two-piece design with extended side plates and wrap around post design. Easy retrofit installations.
Installation:
Use all specified fasteners. See Product Notes, page 10.
These products are designed to work with single, solid-sawn beams, but can be used with built-up beams. When installed to
multiple beams made up of 2x lumber and shims, fasten the plys and shims together to act as a unit.
PB, PBES, and PBS post caps are to be installed in pairs.
F2
Uplift
W1
L2
W2
L1
Typical PB-TZ
installation
Typical C44
installation
Typical BC400-TZ
installation
Typical PBS
installation
H2
H2
H2
H1
H1
H1
W1
W2
L1
4x4
BC400-TZ
4x4
4x4
Rough
4x6
4x6
Rough
6x6
6x6
Rough
8x8
C44
4x4-6
6x6-6
W1
W1
PB44-6TZ
C44
BC400-TZ
USP
Stock No.
L2
H1
H2
Post
Size
Typical PBES
installation
H2
L2
L1
Post
Ref. No.
BCS2-2/4,
BCS2-2/4Z
BC4
W2
H1
H2
L1
L2
Qty
Type
Qty
3-9/16
3-1/8
2-3/8
3-5/16
-- --
10
3-9/16
3-9/16
2-7/8
2-7/8
3-1/4
3-1/4
16d
L1
W1
PBS
PBES
Factored Resistance (115%)1,2
Beam
W1
H1
L1
Fastener Schedule2,3,4
Dimensions (in)
58
F1
Type
DF-L (Lbs)
F1
2220
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
F2
Uplift
F1
F2
Uplift
F1
F2
Uplift
F1
F2
845
1005
5.69
3.76
4.47
905
60
715
4.03
0.27
Uplift
3.18
2220
1885
9.88
9.88
8.39
1575
1575
1340
7.01
7.01
5.96
C44R
BC4R
2-5/8
2-5/8
3-1/4
3-1/4
16d
16d
2220
2220
1885
9.88
9.88
8.39
1575
1575
1340
7.01
7.01
5.96
C46
BC46
3-9/16
5-1/2
2-9/16
2-5/8
3-3/8
5-1/4
16d
10
16d
2220
2220
1885
9.88
9.88
8.39
1575
1575
1340
7.01
7.01
5.96
2-3/4
2-3/4
3-1/4
5-1/4
16d
10
16d
2220
2220
1885
9.88
9.88
8.39
1575
1575
1340
7.01
7.01
5.96
C66
C46R
BC6
5-1/2
5-1/2
2-7/8
2-7/8
5-1/4
5-1/4
12
16d
12
16d
4125
4125
2270
18.35
18.35
10.10
2925
2925
1610
13.01
13.01
7.16
C66R
BC6R
5-1/4
5-1/4
10
16d
10
16d
4360
4360
2055
19.40
19.40
9.14
3095
3095
1455
13.77
13.77
6.47
C88
BC8
LPC4Z
-- -LPC6Z
-- -ACE4,
LCE4
ACE6
AC4
7-1/2
1-1/2
1-1/2
1-1/2
1-1/2
7-1/2
-- --- --- --- --
16
8
8
8
8
16d
16d HDG
N16C-GC
16d HDG
N16C-GC
16
8
8
8
8
16d
16d HDG
N16C-GC
16d HDG
N16C-GC
4360
1885
1885
1885
1885
4360
665
665
665
665
2120
1210
1210
1210
1210
19.40
8.39
8.39
8.39
8.39
19.40
2.96
2.96
2.96
2.96
9.43
5.38
5.38
5.38
5.38
3095
1340
1340
1340
1340
3095
470
470
470
470
1505
855
855
855
855
13.77
5.96
5.96
5.96
5.96
13.77
2.09
2.09
2.09
2.09
6.69
3.80
3.80
3.80
3.80
1-1/2
1-1/2
1-7/16
PB44-6TZ2
2
PB44-6GC
PB66-6TZ2
2
PB66-6GC
4x4
PBES442
6x6
4x4
4x4
Rough
6x6
6x6
Rough
PBES662
PBS442
PBS44R2
-- --
2-13/16 2-13/16
5
2-1/8
2-1/8
2-1/2
2-1/2
5
1-1/2
1-1/2
3
3
7-3/8
3-5/8
3-5/8
5-9/16
5-9/16
7-3/8
-- --- --- --- --
-- --
2-3/8
2-3/4
3-1/4
4-3/4
16d
16d
1915
1050
4150
8.52
4.67
18.46
1355
745
2950
6.03
3.31
13.12
-- --- --
2-3/8 2-1/8
5-1/2
2-5/16 2-13/16 3-9/16
7
6-1/2
8
12
16d
16d
8
12
16d
16d
2400
3800
1685
2250
3480
5850
10.68
16.90
7.50
10.01
15.48
26.02
1700
2695
1195
1600
2475
4150
7.56
11.99
5.32
7.12
11.01
18.46
AC4R
1-1/2
-- --
2-5/16
2-3/16
16d
16d
1915
1050
4150
8.52
4.67
18.46
1355
745
2950
6.03
3.31
13.12
PBS662
AC6
1-1/4
-- --
2-5/16
2-7/8
5-1/2
14
16d
12
16d
3785
2190
4295
16.84
9.74
19.11
2685
1560
3045
11.94
6.94
13.55
PBS66R
AC6R
1-1/4
-- --
2-5/16
2-3/16
8-1/2
10
16d
10
16d
2400
1685
3480
10.68
7.50
15.48
1700
1195
2475
7.56
5.32
11.01
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) Factored resistances and nail schedules for two-piece models are per pair of post caps.
3) Minimum nail embedment shall be 8 nail diameters (typ).
4) NAILS:
New products or updated product information are designated in red font.
1-800-328-5934 www.USPconnectors.com
Materials: 18 gauge
Finish: G90 galvanizing, BC400-TZ, PB44-6TZ &PB66-6TZ G-185 galvanizing; PB44-6GC & PB66-6GC Gold Coat
Options: C44, C46, C46R, C66, C66R, PBS44, PBS66, PBS66R, PBES44, & PBES66 are available in Triple Zinc.
To order, add TZ to stock number, as in PBS44-TZ. C44, PBES44, PBES66, PBS44 & PBS66 are available in
Stainless Steel. To order, add SS to stock number, as in C44-SS.
Codes: Load values are derived from data submitted to various North American building code evaluators.
Materials: 18 gauge
Finish: G-185 galvanizing
Installation:
Use all specified fasteners. See Product Notes, page 10.
Install PBC on outside corner of post forming tabs to inner side
of post.
Assumes beam members are bevel cut at corner.
Typical PBC
installation
W
Dimensions (in)
2,3
Post
Post
Size
4x4
6x6
USP
Steel
Stock No. Ref. No. Gauge
W
PBC44-TZ -- -18
4-15/16
PBC66-TZ -- -18
6-15/16
Fastener Schedule
Factored Resistance
Beam
DF-L (115%)
F1
F2
S-P-F (115%)
Uplift
F1
F2
Uplift
L Qty Type Qty Type Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN
6-1/2 8 16d HDG 8 16d HDG 900 4.00 900 4.00 1800 8.01 775 3.45 775 3.45 1555 6.92
6-1/2 8 16d HDG 8 16d HDG 900 4.00 900 4.00 1800 8.01 775 3.45 775 3.45 1555 6.92
PBC
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for
other load durations in accordance with the code.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) NAILS:
Installation:
Attach base to post with (4) 10d HDG nails.
Attach post to concrete using 1/2 diameter rod into concrete and
extend into wood member.
Not recommended for fence posts or other unrestrained (not
fixed or fastened at top) applications. These anchors are not
designed to resist overturning (moment) loads.
Dimensions (in)
Post
Size
4x4
4x6
5x5
6x6
8x8
USP
Stock No. Ref. No.
CPB44
CPS4
CPB46
CPS46
CPB55
CPS5
CPB66
CPS6
CPB88
CPS7
W1
3-1/4
3-5/16
4-1/8
5-5/16
7-1/4
W2
3-1/4
5-5/16
4-1/8
5-5/16
7-1/4
Bottom
Surface
Bearing
Area
2.2
3.3
3.0
3.9
6.4
Fastener Schedule5
Qty
4
4
4
4
4
Type
10d HDG
10d HDG
10d HDG
10d HDG
10d HDG
Typical CPB
installation
Factored
Resistance1,2
Concrete Bearing
Strength3,4
Lbs
5235
6810
6295
8570
12490
Lbs
6545
9820
8925
11600
19040
kN
23.29
30.29
28.00
38.12
55.56
kN
29.11
43.68
39.70
51.60
84.70
1
W2
W1
CPB
1-800-328-5934 www.USPconnectors.com
USP2240-131
59
Typical KCCQ44
centre cap
installation
Installation:
Use all specified fasteners. See Product Notes, page 10.
WS3 Wood Screws, 1/ 4 dia. x 3 long, are supplied with KCCQ and KECCQ
Column Caps.
Beams shall be designed to support the required loads. Beam shear may limit
loads to less than listed loads for device. A design professional shall determine
the adequacy of the stud to resist published loads.
W2
KCCQ44
W1
L
H
Typical KECCQ44
end cap
installation
W2
KECCQ44
Fastener Schedule4
Dimensions (in)
Beam
USP
Stock No.
Ref. No.
Steel
Gauge
W1
W2
Column
or Post
Factored Resistance3
DF-L
Bearing
(100%)2
Lbs
kN
S-P-F
Uplift
(115%)1,8
Lbs
kN
Bearing
(100%)2
Lbs
kN
Uplift
(115%)1,8
Lbs
kN
KCCQ325-4
CCQ3-4SDS2.5
11
16
WS3
14
KCCQ325-6
CCQ3-6SDS2.5
11
16
WS3
14
KCCQ44
CCQ44SDS2.5
11
16
WS3
14
11
16
WS3
14
11
16
WS3
14
KCCQ45
KCCQ46
-- -CCQ46SDS2.5
KCCQ47
-- --
11
16
WS3
14
KCCQ47X
-- --
13
16
WS3
14
KCCQ48
CCQ48SDS2.5
11
16
WS3
14
KCCQ525-4
CCQ5-4SDS2.5
5-1/4 3-5/8
13
16
WS3
14
KCCQ525-6
CCQ5-6SDS2.5
5-1/4 5-1/2
13
16
WS3
14
KCCQ525-8
CCQ5-8SDS2.5
5-1/4 7-1/2
13
16
WS3
14
11
16
WS3
14
KCCQ57
-- --
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) Bearing loads are based on compression perpendicular to grain values published in the 2001 NDS and soft converted to Limit States Design.
3) Factored resistances are based on lumber with a specific gravity of DF-L = 0.49 and S-P-F = 0.42 and a moisture content of 19% or less.
5) Beams shall be designed to support the required loads. Beam shear may limit loads to less than listed loads for device.
6) The designer shall check post for required loads.
7) Spliced conditions must be detailed by the specifier to transfer tension loads between spliced members by means other than the column cap.
8) Uplift loads do not apply to splice conditions.
60
1-800-328-5934 www.USPconnectors.com
W1
continued
Installation:
Use all specified fasteners. See Product Notes, page 10.
WS3 Wood Screws, 1/ 4 dia. x 3 long, are supplied with KCCQ and KECCQ Column
Caps.
Beams shall be designed to support the required loads. Beam shear may limit loads to
less than listed loads for device. A design professional shall determine the adequacy of
the stud to resist published loads.
Fastener Schedule4
Dimensions (in)
Beam
USP
Stock No.
Ref. No.
Steel
Gauge W1
W2
Column
or Post
Factored Resistance3
DF-L
Bearing
(100%)2
Lbs
kN
S-P-F
Uplift
(115%)1,8
Lbs
kN
Bearing
(100%)2
Lbs
kN
Uplift
(115%)1,8
Lbs
kN
KCCQ64
CCQ64SDS2.5
11
16
WS3
14
40.79
KCCQ66
CCQ66SDS2.5
11
16
WS3
14
40.79
KCCQ67X
CCQ6-7.13SDS2.5
11
16
WS3
14
40.79
KCCQ68
CCQ68SDS2.5
11
16
WS3
14
40.79
KCCQ74
CCQ74SDS2.5
11
16
WS3
14
40.79
KCCQ76
CCQ76SDS2.5
11
16
WS3
14
40.79
KCCQ77
CCQ77SDS2.5
11
16
WS3
14
40.79
KCCQ78
CCQ78SDS2.5
11
16
WS3
14
40.79
KCCQ71-4
CCQ7.1-4SDS2.5
11
16
WS3
14
40.79
KCCQ71-6
CCQ7.1-6SDS2.5
11
16
WS3
14
40.79
KCCQ71-71
CCQ7.1-7.1SDS2.5
11
16
WS3
14
40.79
KCCQ71-8
CCQ7.1-8SDS2.5
11
16
WS3
14
40.79
11
16
WS3
14
40.79
11
16
WS3
14
40.79
KCCQ84
-- --
KCCQ86
CCQ86SDS2.5
KCCQ88
CCQ88SDS2.5
KCCQ94
-- --
11
16
WS3
14
40.79
11
16
WS3
14
40.79
CCQ96SDS2.5
11
16
WS3
14
40.79
KCCQ98
CCQ98SDS2.5
11
16
WS3
14
40.79
KCCQ106
CCQ106SDS2.5
11
16
WS3
14
40.79
40.79
KCCQ96
WS3
14
8370
WS3
14
8370
40.79
WS3
14
9505
40.79
-- -
WS3
14
9505
40.79
WS3
14
8370
40.79
40.79
-- --
WS3
14
9505
-- --
WS3
14
9505
40.79
WS3
14
8370
40.79
5-1/4 3-5/8
9-1/2 16
WS3
14
40.79
5-1/4 5-1/2
9-1/2 16
WS3
14
40.79
5-1/4 7-1/2
9-1/2 16
WS3
14
40.79
WS3
14
40.79
-- --
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) Bearing loads are based on compression perpendicular to grain values published in the 2001 NDS and soft converted to Limit States Design.
3) Factored resistances are based on lumber with a specific gravity of DF-L = 0.49 and S-P-F = 0.42 and a moisture content of 19% or less.
"&#" ('( "%&$ %!#
5) Beams shall be designed to support the required loads. Beam shear may limit loads to less than listed loads for device.
6) The designer shall check post for required loads.
7) Spliced conditions must be detailed by the specifier to transfer tension loads between spliced members by means other than the column cap.
8) Uplift loads do no apply to splice conditions.
USP2240-131
61
continued
Installation:
Use all specified fasteners. See Product Notes, page 10.
WS3 Wood Screws, 1/ 4 dia. x 3 long, are supplied with KCCQ and KECCQ Column
Caps.
Beams shall be designed to support the required loads. Beam shear may limit loads to
less than listed loads for device. A design professional shall determine the adequacy of
the stud to resist published loads.
Dimensions (in)
Beam
W1
W2
S-P-F
DF-L
Bearing
(100%)2
Lbs
kN
Uplift
(115%)1,8
Lbs
kN
Bearing
(100%)2
Lbs
kN
Uplift
(115%)1,8
kN
Lbs
KECCQ64
ECCQ64SDS2.5
WS3
14
KECCQ66
ECCQ66SDS2.5
WS3
14
KECCQ67X
ECCQ6-7.13SDS2.5
WS3
14
KECCQ68
ECCQ68SDS2.5
WS3
14
KECCQ74
ECCQ74SDS2.5
WS3
14
KECCQ76
ECCQ76SDS2.5
WS3
14
KECCQ77
ECCQ77SDS2.5
WS3
14
KECCQ78
ECCQ78SDS2.5
WS3
14
KECCQ71-4
ECCQ7.1-4SDS2.5
WS3
14
KECCQ71-6
ECCQ7.1-6SDS2.5
WS3
14
KECCQ71-71
ECCQ7.1-7.1SDS2.5
WS3
14
KECCQ71-8
ECCQ7.1-8SDS2.5
WS3
14
-- --
WS3
14
KECCQ84
KECCQ86
ECCQ86SDS2.5
WS3
14
KECCQ88
ECCQ88SDS2.5
WS3
14
WS3
14
KECCQ94
Ref. No.
Steel
Gauge
Column
or Post
-- --
KECCQ96
ECCQ96SDS2.5
WS3
14
KECCQ98
ECCQ98SDS2.5
WS3
14
KECCQ106
ECCQ106SDS2.5
WS3
14
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) Bearing loads are based on compression perpendicular to grain values published in the 2001 NDS and soft converted to Limit States Design.
3) Factored resistances are based on lumber with a specific gravity of DF-L = 0.49 and S-P-F = 0.42 and a moisture content of 19% or less.
5) Beams shall be designed to support the required loads. Beam shear may limit loads to less than listed loads for device.
6) The designer shall check post for required loads.
7) Spliced conditions must be detailed by the specifier to transfer tension loads between spliced members by means other than the column cap.
8) Uplift loads do not apply to splice conditions.
Speciality Options:
For end column caps, add an E after the K in the stock number, as in KECCQ325-4.
Straps may be rotated 90 on special order where the W2 dimension is less than or equal to
the W1 dimension.
KCCQO/KECCQO Cap only, no strap design for field welding to pipe or other columns.
KCCQOB For cross beam connections. Any two buckets can be welded together for a wide
variety of applications. Allowable load shall be the lesser of the two components.
KCCQT For T beam intersections, consult USP. Specify beam/column conditions,
dimensions, and loading requirements.
KCCQC For X beam intersections, consult USP. Specify beam/column conditions,
dimensions, and loading requirements.
KECCQLL/R For L beam intersections, consult USP. Specify left (L) or right (R) beam/column
conditions, dimensions, and loading requirements.
Dimension call-outs not shown in the table must be specified at time of ordering for
specialty options, non-catalog, or rough/full size lumber sizes.
62
USP
Stock No.
Factored Resistance3
Fastener Schedule4
continued
4
Typ.
W3
L
L1
H2
H3
H1
L
H1
W4
H
H2
W1
L2
W2
KCCQC
W2
W1
KCCQO
KCCQOB
4 Typ.
H2
1/4
unless
otherwise
specified
H2
H1
H1
W3
W3
W1
W1
W2
Optional KECCQ
Rotated Straps 90
KECCQLL
left shown
W2
KCCQT
Caps & Bases
KECCQLL
rotated 90 left
KCCQ
offset left
KECCQLR
rotated 90 right
KCCQ
offset right
left
right
KECCQ
rotated 45 left
1-800-328-5934 www.USPconnectors.com
KECCQ
offset left
KECCQ
offset right
KECCQ
rotated 45 right
USP2240-131
63
MP Series
Field adjustable framing angle.
MPA1
MP34
MP
MP_F
RBC
A3
AC
JA1
RSPT
SPT22
MP_F Series
Multi-purpose framing plate.
A3 & AC Series
Framing angles for joist support.
JA Series
Heavier-capacity framing angle for joist support.
SPT
SPTH
LJQ Series
Higher capacity sill plate to floor joist connector.
LJC-TZ
LJQ-TZ
ANJ44S-HDG
B & BL Series
L-shaped corner braces.
KHL Series
Heavy-capacity corner framing angle.
BL
Ornamental Series
Connectors with ornamental notching.
L/LH
KHL
T/TH
KHL33-O
64
SFC
HH
RBC
Field adjustable roof boundary clip.
CMST/CMSTC
RS Series
114 wide coiled strapping.
RS
LSTA/MSTA
ST
HRS Series
13 8 or 31 4 wide flat strapping.
HRS
KST
HTP Series
3 wide flat strapping.
KSTI
MSTC Series
3 wide flat strapping.
HTP
LSTI
3 34 wide flat strapping for open web trusses.
MSTC
KRPS Series
Protection strap for pipes placed in partitions.
LSTI
MSTCB Series
Pre-bent strap.
KRPS
MSTCB
LTW Series
Light-capacity twist strap.
MTW Series
Medium-capacity twist strap.
HTW Series
Heavy-capacity twist strap.
LFTA6
LTW
MTW/HTW
KTS
PWFS24
KTS Series
Medium-capacity angled twist strap.
HTWMSeries
Heavy-capacity twist strap.
MSTAM
1-800-328-5934 www.USPconnectors.com
MSTCM
HTWM
USP2240-131
65
2 13/16
Figure 1
MP34
4 1/2
4 1/2
1 7/16
1 1/2
MPA1-GC
Figure 2
1 7/16
1 1/2
MPA1
Figure 3
A2
F1
A1
C1
B2
C2
F2
Typical MPA1
joist / header installation
B1
Typical MPA1
rafter / plate installation
Typical MPA1
stud / plate installation
Figure 4
F1
Hangers
F2
66
F3
F3
Typical MP34
joist / header installation
continued on next page
1-800-328-5934 www.USPconnectors.com
Installation:
Use all specified fasteners. See Product Notes, page 10.
Bend tabs only once.
MP4F connects 2x framing with floor sheathing up to 5 8.
MP6F connects 3x framing with floor sheathing up to 34. Better choice for
connections where floor sheathing is between sole plate and rim board.
1 1/2
1 7/16
MP4F
Type 1
MP4F = 3
MP6F = 3 3/4
MP4F = 1
MP6F = 1 3/4
Type 2
MP4F
Sheathing
4 1/4
MP_F
Typical MP_F
installation
Fastener Schedule3,5,6
USP
Stock No.
Steel Installation
Type2
Ref. No. Gauge
Figure 1
MPA1
A35
18
Figure 2
Figure 3
Figure 1
MPA1-GC
-- --
18
Figure 2
Figure 3
MP34
A34
18
Figure 4
Type 2
MP4F
LTP4
20
Type 1
Type 2
Type 1
Type 2
MP6F
LTP5
20
Type 1
Type 2
Factored Resistance1,3,4
Joist or Plate
Qty
Type
Qty
Type
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
N8-GC
N8-GC
N8-GC
N8-GC
N8-GC
N8-GC
N8-GC
N8-GC
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d
8d
8d
8d
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d
8d
8d
8d
6
6
3
3
3
6
6
6
6
6
3
3
3
6
6
6
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
N8-GC
N8-GC
N8-GC
N8-GC
N8-GC
N8-GC
N8-GC
N8-GC
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d
8d
8d
8d
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d x 1-1/2
8d
8d
8d
8d
Direction
2
of Load
F1
F2
A1
B1
C1
A2
B2
C2
F1
F2
A1
B1
C1
A2
B2
C2
F1
F2
F3
V
H
V
H
V
H
V
H
V
H
V
H
V
H
V
H
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
100%
115%
100%
115%
100%
115%
100%
115%
1115
1300
685
510
525
830
460
610
1115
1300
685
510
525
830
460
610
855
1025
555
1380
1380
1380
1380
1380
1380
1380
1380
995
995
995
995
995
995
995
995
1280
1300
785
585
600
955
525
705
1280
1300
785
585
600
955
525
705
985
1025
635
1585
1585
1585
1585
1585
1585
1585
1585
1145
1145
1145
1145
1145
1145
1145
1145
4.96
5.78
3.05
2.27
2.34
3.69
2.05
2.71
4.96
5.78
3.05
2.27
2.34
3.69
2.05
2.71
3.80
4.56
2.47
6.14
6.14
6.14
6.14
6.14
6.14
6.14
6.14
4.43
4.43
4.43
4.43
4.43
4.43
4.43
4.43
5.69
5.78
3.49
2.60
2.67
4.25
2.34
3.14
5.69
5.78
3.49
2.60
2.67
4.25
2.34
3.14
4.38
4.56
2.82
7.05
7.05
7.05
7.05
7.05
7.05
7.05
7.05
5.09
5.09
5.09
5.09
5.09
5.09
5.09
5.09
790
925
485
360
370
590
325
435
790
925
485
360
370
590
325
435
610
725
395
980
980
980
980
980
980
980
980
705
705
705
705
705
705
705
705
910
925
555
415
425
675
375
500
910
925
555
415
425
675
375
500
700
725
450
1125
1125
1125
1125
1125
1125
1125
1125
815
815
815
815
815
815
815
815
3.51
4.11
2.16
1.60
1.65
2.62
1.45
1.94
3.51
4.11
2.16
1.60
1.65
2.62
1.45
1.94
2.71
3.23
1.76
4.36
4.36
4.36
4.36
4.36
4.36
4.36
4.36
3.14
3.14
3.14
3.14
3.14
3.14
3.14
3.14
4.05
4.11
2.47
1.85
1.89
3.00
1.67
2.22
4.05
4.11
2.47
1.85
1.89
3.00
1.67
2.22
3.11
3.23
2.00
5.00
5.00
5.00
5.00
5.00
5.00
5.00
5.00
3.63
3.63
3.63
3.63
3.63
3.63
3.63
3.63
Type 1
Header or Stud
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) Refer to drawings for installation type and definition of the various load directions.
3) If installing MP4F or MP6F over plywood, use 8d common nails for 100% of table load.
4) Factored resistances are shown per angle. When using a single anchor, joist must be constrained from rotation.
5) Minimum nail embedment shall be 8 nail diameters (typ).
6) NAILS:
1-800-328-5934 www.USPconnectors.com
USP2240-131
67
Materials: 20 gauge
Finish: G90 galvanizing
Codes: Load values are derived
from data submitted to
various North American
building code evaluators.
Typical RBC
Top-Plate to Outside of Blocking
installation
Typical RBC
Top-Plate to Inside of Blocking
installation
Typical RBC
1 foamboard installation
Typical RBC
Concrete Blockwall to Blocking
installation
RBC
Fastener Schedule2,3,4
Dimensions (in)
Top Plate
USP
Steel
Stock No. Ref. No. Gauge
RBC
RBC
20
4-1/4
Installation
Type
Qty
Wood to Wood 6
Wood to CMU 3
Factored Resistance1
Blocking
F1 (115%)
DF-L
Type2
10d x 1-1/2
1/4" Tapcon
Qty
Type2
6 10d x 1-1/2
6 10d x 1-1/2
Lbs
990
735
kN
4.40
3.27
S-P-F
Lbs
615
525
68
1-800-328-5934 www.USPconnectors.com
kN
2.74
2.34
Installation:
Use all specified fasteners.See
Product Notes, page 10.
Field adjustable from 0 to 90.
Bend angle only once.
Load
direction
Typical MP
installation
2 1/4
2 1/4
Typical MP
Rafter Support
Typical JA1
installation
F2
MP
F1
F1
W2
W1
JA3
W2
W2
W1
A3
AC
continued on next page
1-800-328-5934 www.USPconnectors.com
Typical AC
installation
Typical JA7
installation
W1
F2
USP2240-131
69
Dimensions (in)
USP
Stock No.
A3
MP5
MP7
MP7-GC
MP9
MP9-GC
A23, GA1,
GA2, L30,
S/A23
LS30
LS50,
S/LS50
LS70,
S/LS70
-- -LS90
-- --
Steel
Gauge
Header
W1
W2
Qty
Type
Factored Resistance
Joist
Qty
Type
S-P-F (kN)
100%
115%
100%
115%
100%
115%
F1
970
1115
4.31
4.96
690
792
3.07
3.52
F2
985
1130
4.38
5.03
700
802
3.11
3.57
2-3/4
10d x 1-1/2
10d x 1-1/2
18
2-1/4
2-1/4
3-3/8
10d
10d
F1
750
860
3.34
3.83
535
615
2.38
2.74
18
2-1/4
2-1/4
4-5/8
10d
10d
F1
1335
1535
5.94
6.83
950
1095
4.23
4.87
18
2-1/4
2-1/4
5-7/8
10d
10d
5
6
6
N10C-GC
10d
N10C-GC
5
6
6
N10C-GC
10d
N10C-GC
18
2-1/4
2-1/4
6-7/8
16
1-5/16
2-3/8
4-7/8
10d
10d
AC7
L70
16
1-5/16
2-3/8
6-15/16
10d
10d
16
1-5/16
2-3/8
6-15/16
N10C-GC
N10C-GC
AC9
L90
16
1-5/16
2-3/8
8-7/8
10d
10d
JA1
A21
16
1-1/2
1-1/2
1-1/4
10d x 1-1/2
10d x 1-1/2
JA3
-- --
14
2-1/2
2-1/2
16d
10d x 1-1/2
JA5
-- --
14
2-1/2
2-1/2
16d
10d x 1-1/2
JA7
-- --
14
2-1/2
2-1/2
16d
10d x 1-1/2
JA9
-- --
14
2-1/2
2-1/2
10
16d
10
10d x 1-1/2
F1
F1
F1
F2
F1
F2
F1
F2
F1
F2
F1
F2
F1
F2
F1
F2
F1
F2
F1
F2
1740
2005
7.74
8.92
1235
1420
5.49
6.32
1740
1980
1980
995
930
1120
1335
1120
1335
1860
1335
421
562
963
874
1556
1665
3058
2664
3767
2697
2005
2280
2280
1145
1070
1285
1535
1285
1535
2135
1535
484
647
1108
1005
1790
1915
3517
3064
4333
3102
7.74
8.81
8.81
4.43
4.14
4.98
5.94
4.98
5.94
8.27
5.94
1.87
2.50
4.28
3.89
6.92
7.41
13.60
11.85
16.76
12.00
8.92
10.14
10.14
5.09
4.76
5.72
6.83
5.72
6.83
9.50
6.83
2.15
2.88
4.93
4.47
7.96
8.52
15.64
13.63
19.27
13.80
1235
1405
1405
705
660
795
950
795
950
1320
950
299
399
684
620
1105
1182
2171
1892
2675
1915
1420
1615
1615
815
760
910
1090
910
1090
1515
1090
344
459
786
713
1271
1360
2497
2176
3076
2202
5.49
6.25
6.25
3.14
2.94
3.54
4.23
3.54
4.23
5.87
4.23
1.33
1.78
3.04
2.76
4.91
5.26
9.66
8.42
11.90
8.52
6.32
7.18
7.18
3.63
3.38
4.05
4.85
4.05
4.85
6.74
4.85
1.53
2.04
3.50
3.17
5.65
6.05
11.11
9.68
13.68
9.80
70
S-P-F (Lbs)
115%
1-7/16 1-7/16
L50
-- --
DF-L (kN)
100%
18
AC5
AC7-GC
DF-L (Lbs)
Direction
of Load
1-800-328-5934 www.USPconnectors.com
MP3
Ref. No.
Fastener Schedule
F1
Uplift
F2
Typical SPT24
installation
Typical SPT4
installation
Installation:
Use all specified fasteners. See Product Notes, page 10.
H
H
H
W
RSPT6
1 1/4
SPT22
SPT
RSPT6-2
Nailing concentrated on
top plate for greater
resistance
Locator
tab
Reinforcement
ribs
F2
F1
Uplift
USP
Stud
3
Size Stock No.
2x
SPT22
2x
SPT24
4x
SPT44
2x
RSPT4
2x
RSPT6
(2) 2x RSPT6-2
4x
SPT4
6x
SPT6
8x
SPT8
SPTH4
4x
SPTHW4
SPTH6
6x
SPTHW6
8x
SPTH8
Ref. No.
SP1
SP2
-- -RSP4
SSP
DSP
SP4
SP6
SP8
SPH4
SPH4R
SPH6
SPH6R
SPH8
Steel
Gauge
20
20
20
20
18
18
20
20
20
18
18
18
18
18
Plate
DF-L
F1
W
H
L
1-9/16 4-3/8 3-1/2
1-9/16 5-5/8 3-1/2
3-9/16 6-3/4 6-1/2
1-1/2 4-1/8 -- -1-1/2 5-7/16 -- -2-3/4 5-7/16 -- -3-9/16 6-7/8 -- -5-9/16 7-5/8 -- -7-5/16 8-1/2 -- -3-9/16 8-5/8 -- -4-1/16 8-3/8 -- -5-9/16 9-3/8 -- -6-1/16 9-1/8 -- -7-5/16 8-1/2 -- --
Qty
4
6
6
4
4
8
6
6
6
12
12
12
12
12
Type
10d
10d
16d
8d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
Qty
4
6
6
4
4
6
-- --- --- --- --- --- --- --- --
Type
10d
10d
16d
8d x 1-1/2
10d x 1-1/2
10d x 1-1/2
-- --- --- --- --- --- --- --- --
SPTH
SPTHW similar
RSPT4
Fastener Schedule2,4
Dimensions (in)
1 1/4
Lbs
695
695
845
285
-- --- --- --- --- --- --- --- --
F2
kN
3.09
3.09
3.76
1.27
-- --- --- --- --- --- --- --- --- --- --
Lbs
325
325
310
315
-- --- --- --- --- --- --- --- --- --- --
S-P-F
Uplift
kN
1.45
1.45
1.38
1.40
-- --- --- --- --- --- --- --- --- --- --
Lbs
755
1125
1355
585
740
1115
960
960
960
1275
1275
1275
1275
1275
kN
3.36
5.00
6.03
2.60
3.29
4.96
4.27
4.27
4.27
5.67
5.67
5.67
5.67
5.67
F1
Lbs
600
600
725
245
-- --- --- --- --- --- --- --- --- --- --
F2
kN
2.67
2.67
3.23
1.09
-- --- --- --- --- --- --- --- --- --- --
Lbs
280
280
265
270
-- --- --- --- --- --- --- --- --- --- --
Uplift
kN
1.25
1.25
1.18
1.20
-- --- --- --- --- --- --- --- --- --- --
Lbs
650
970
1165
505
635
960
825
825
825
1095
1095
1095
1095
1095
kN
2.89
4.31
5.18
2.25
2.82
4.27
3.67
3.67
3.67
4.87
4.87
4.87
4.87
4.87
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) SPT22, SPT24, and SPT44: the two nails fastened to the wide face of the stud must be driven 30 from the perpendicular on the horizontal plane.
4) NAILS:
1-800-328-5934 www.USPconnectors.com
USP2240-131
71
LJC-TZ fastens the top side of the sill plate to the underside of the floor joist preventing splitting of the bottom chord flanges,
and can be installed after the floor system has been installed. The product is load rated for use with dimension lumber floor
joists as well as I-joist. It can also be used with cantilevered floor joists.
LJQ-TZ is a higher capacity connector designed for higher loads. It is similar in design to a joist hanger with a seat for the
floor joist to bear against and utilizes wood screws to fasten to the sill plate. USPs WS15-GC Wood Screws (included) provide
quick installation without the need to pre-drill holes.
Installation:
Use all specified fasteners. See Product Notes, page 10.
LJC-TZ Installs after the floor joist has been placed with a minimum of (12) 8d x 1-1/2 HDG nails.
LJQ-TZ Installs with (4) USP WS15-GC Wood Screws. WS15-GC Wood Screws are 1/4 diameter x 1-1/2 long and are
included with LJQ-TZ connectors.
L
3 3/16
L
1/2
USP
Stock No.
LJC-TZ
LJQ15-TZ
LJQ17-TZ
LJQ20-TZ
LJQ23-TZ
LJQ25-TZ
LJQ35-TZ
Steel
Ref. No. Gauge
-- -18
-- -16
-- -16
-- -16
-- -16
-- -16
-- -16
3-3/16
1-9/16
1-13/16
2-1/8
2-5/16
2-9/16
3-9/16
8
3
3
3
3
3
3
-- -1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
Qty
12
4
4
4
4
4
4
LJQ-TZ
Fastener
Schedule1,2,3
DF-L
2x
LJC-TZ
Type
8d x 1-1/2 HDG
WS15-GC
WS15-GC
WS15-GC
WS15-GC
WS15-GC
WS15-GC
S-P-F
I-Joist
2x
I-Joist
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
1310
1880
1880
1880
1880
1880
2205
5.83
8.36
8.36
8.36
8.36
8.36
9.81
1310
1880
1880
1880
1880
1880
2205
5.83
8.36
8.36
8.36
8.36
8.36
9.81
930
1335
1335
1335
1335
1335
1565
4.14
5.94
5.94
5.94
5.94
5.94
6.96
930
1335
1335
1335
1335
1335
1565
4.14
5.94
5.94
5.94
5.94
5.94
6.96
Installation:
Install with (2) 1/2 x 2 lag screws into each leg.
4
3 1/2
ANJ44S-HDG
Fastener Schedule1
Dimensions (in)
Header
USP
Stock No.
ANJ44S-HDG
Steel
Ref. No. Gauge W
-- -7
3-1/2
H
4
L
4
Qty
2
Factored Resistance
Joist
Lag
Screw
Qty
2
Lag
Screw
DF-L
S-P-F
F1
115%
F1
115%
Lbs
845
kN
3.76
Lbs
600
kN
2.67
72
1-800-328-5934 www.USPconnectors.com
F1
Typical ANJ44S-HDG
installation
Installation:
Use all specified fasteners. See Product Notes, page 10.
Dimensions (in)
USP
Steel
Stock No. Ref. No. Gauge
B23
-- -12
B24
BL3
BL4
BL6
BL8
B66
B88
-- -A33
A44
-- --- -A66
A88
12
12
12
12
12
12
12
Fastener Schedule
1,3
Nails
Bolts
W
2
L
2-5/8
Qty
6
Type
16d
Qty
-- --
Dia.
-- --
2
1-1/4
1-1/4
1-1/4
1-1/4
1-1/2
2
3-5/8
3-1/16
4-13/16
6-9/16
8-5/16
6
8
8
8
10
12
14
-- --- --
16d
16d
16d
16d
16d
-- --- --
Typical B66
installation
Some model
designs may
vary from
illustration
shown
B66
L
W
B23
NEWS
SIZE
BL4
D2
D1
W2
D4
W1
D3
KHL55
USP
Stock No.
KHL33
KHL35
KHL35G
KHL37
KHL335
KHL43
KHL46
KHL49
KHL53
KHL55
KHL57
KHL73
KHL76
KHL79
Steel
Gauge
Ref. No.
HL33
7
HL35
7
HL35G
7
HL37
7
SPECANGLE
3
HL43
3
HL46
3
HL49
3
HL53
7
HL55
7
HL57
7
HL73
3
HL76
3
HL79
3
Fastener Schedule
Bolts1
W1
3-1/4
3-1/4
3-1/4
3-1/4
3-1/2
4-1/4
4-1/4
4-1/4
5-3/4
5-3/4
5-3/4
7-1/4
7-1/4
7-1/4
W2
3-1/4
3-1/4
3-1/4
3-1/4
5-1/4
4-1/4
4-1/4
4-1/4
5-3/4
5-3/4
5-3/4
7-1/4
7-1/4
7-1/4
L
2-1/2
5
5
7-1/2
3-1/2
3
6
9
2-1/2
5
7-1/2
3
6
9
D1
1-1/4
1-1/4
1-1/4
1-1/4
-- -1-1/2
1-1/2
1-1/2
1-1/4
1-1/4
1-1/4
1-1/2
1-1/2
1-1/2
D2
-- -2-1/2
2-1/2
2-1/2
-- --- -3
3
-- -2-1/2
2-1/2
-- -3
3
D3
D4
2
-- -2
-- -2
-- -2
-- --- --- -2-3/4 -- -2-3/4 -- -2-3/4 -- -2
2-1/2
2
2-1/2
2
2-1/2
2-3/4
3
2-3/4
3
2-3/4
3
Qty
2
4
4
6
4
2
4
6
4
8
12
4
8
12
Dia.
5/8
5/8
5/8
5/8
1/2
3/4
3/4
3/4
5/8
5/8
5/8
3/4
3/4
3/4
Dimensions (in)
Gussets
Qty
-- --- -1
-- --- --- --- --- --- --- --- --- --- --- --
Typical KHL35
installation
gusset
KHL35G
1-800-328-5934 www.USPconnectors.com
USP2240-131
73
Materials: 14 gauge
Finish: G90 galvanizing; TH12-HDG Hot-dip galvanized
Options: L6 and T6 are available in Triple Zinc. To order, add
TZ to stock number, as in L6-TZ.
LH12 is available in Hot-dip galvanized. To order, add
HDG to stock number, as in LH12-HDG.
H
L
TH12-HDG
TH16
LH12
LH16
Ref. No.
66T
-- -128T
1212T
66L
88L
1212L
1212HT,
1212HTHDG
1616HT
1212HL
1616HL
Steel
Gauge W
14
1-1/2
14
2
14
2
14
2
14
1-1/2
14
2
14
2
T6
USP
Stock No.
T6
T8
T12
T1212
L6
L8
L12
Installation:
Use all specified fasteners. See Product Notes, page 10.
Straps are not load rated.
Dimensions (in)
L6
Fastener Schedule
2
1,3
Bolts
Nails
H
5
8
8
12
6
8
12
L
6
8-1/2
12
12
6
8
12
Qty
3
3
3
3
2
2
4
Dia.
1/2
1/2
1/2
1/2
1/2
1/2
1/2
Qty
12
12
12
12
8
8
12
Type
16d
16d
16d
16d
16d
16d
16d
2-1/2
12
12
5/8
-- --
-- --
7
7
7
2-1/2
3
2-1/2
16
12
16
16-1/4
12
16
6
5
7
5/8
5/8
5/8
-- --- --- --
-- --- --- --
TH16
LH12
Ornamental series
Ornamental notching provides architectural appearance for
exposed applications.
3 1/4
Installation:
Use all specified fasteners. See Product Notes, page 10.
Connectors are not load rated.
L
2 1/2
KHL33-O
1
Dimensions (in)
Bolt Schedule
USP
Steel
Stock No. Ref. No. Gauge Description W
H
L
Qty
Dia.
KHL33-O
OHA33
7
Heavy Angle 3-1/4 -- -- 2-1/2
2
5/8
KHL36-O
OHA36
7
Heavy Angle 3-1/4 -- -6
4
5/8
KHST64-O OHS135
7
Strap Tie
6
-- -- 13-1/2
4
3/4
ST12-O
OS
12
Strap Tie
2
-- -12
4
1/2
L12-O
OL
12
'L' Strap
2-1/2 11-7/8 11-7/8
5
1/2
LH12-O
OHL
7
'L' Strap
2-1/2 11-7/8 11-7/8
5
5/8
T1212-O
OT
12
'T' Strap
2-1/2 11-7/8 14-1/2
6
1/2
TH12-O
OHT
7
'T' Strap
2-1/2 11-7/8 11-1/8
4
5/8
TH16-O
-- -7
'T' Strap
2-1/2 11-7/8 16-1/8
6
5/8
1) All bolts shall meet or exceed the specifications of ASTM A 307.
74
H
3 1/4
Some model
designs may
vary from
illustration
shown
1-800-328-5934 www.USPconnectors.com
Installation:
Use all specified fasteners. See Product Notes, page 10.
F1
1,2
Dimensions (in)
Header
USP
Steel
Stock No. Ref. No. Gauge W
H
D
SFC6
FC6
16
5-1/2 2-1/2 2-1/2
Joist
DF-L
F1
Qty
5
Type
16d
Qty
5
Uplift
Factored Resistance
Fastener Schedule
Type
16d
Typical SFC6
installation
S-P-F
F1
Uplift
Uplift
SFC6
F3
Materials: 16 gauge
Finish: G90 galvanizing
Codes: Load values are derived from data submitted to
various North American building code evaluators.
F2
3 3/4
Installation:
Use all specified fasteners. See Product Notes, page 10.
F1
HH66
Dimensions (in) Fastener Schedule1,2
Header
USP
Steel
Stock No. Ref. No. Gauge
W
HH44
HH4
16
3-9/16
HH66
HH6
16
5-1/2
Factored Resistance
DF-L
Stud
F1 (100%)
H
3-1/4
5-1/4
kN
7.94
10.61
S-P-F
F2 (115%)
Lbs
915
1365
Typical HH44
installation
kN
4.07
6.07
F3 (115%)
Lbs
850
1365
kN
3.78
6.07
F1 (100%)
Lbs
1500
2000
kN
6.67
8.90
F2 (115%)
Lbs
590
885
kN
2.62
3.94
F3 (115%)
Lbs
715
1150
kN
3.18
5.12
1-800-328-5934 www.USPconnectors.com
USP2240-131
75
1 1/4
1/2
1 1/2
Clear
Span Cut
Length
USP
Stock No.
Ref. No.
CMSTC16
CMSTC16
16
CMST14
CMST14
14
CMST12
CMST12
Steel Coil
Gauge Length
12
RS300
CS22
22
RS250
CS20
20
RS200
CS18
18
RS100
CS18S
18
RS150
CS16
16
RS14-100
CS14
14
RS22-R
CS22-R
22
RS20-R
CS20-R
20
RS18-R
CS18-R
18
RS16-R
CS16-R
16
RS14-R
CS14-R
14
Cut Length
%
%
%
52-1/2'
%
%
%
40' %
%
%
300'
%
%
250'
%
%
200'
%
%
100'
%
%
150'
%
%
100'
%
%
25'
%
%
25'
%
%
25'
%
%
25'
%
%
25'
%
54'
End
Length
(in)
21"
42"
28"
68"
134"
40"
92"
184"
6"
7"
7"
8"
8"
9"
8"
9"
9"
11"
12"
15"
6"
7"
7"
8"
8"
9"
9"
11"
12"
15"
Fastener
2,3,4,5
Schedule
Qty
Type
56
10d
64
16d
76
10d
88
16d
104
10d
16
18
18
20
20
24
20
24
24
28
30
38
16
18
18
20
20
24
24
28
30
38
10d
8d
10d
8d
10d
8d
10d
8d
10d
8d
10d
8d
10d
8d
10d
8d
10d
8d
10d
8d
10d
8d
Nail
Spacing DF-L (Lbs)
O.C. 100% 115%
%
7070 7070
%
% 9945 9945
%
9945 9945
%
% 13975 13975
%
13975 13975
%
% 1415 1415
% 1415 1415
% 1595 1595
% 1595 1595
% 2100 2100
% 2100 2100
% 2100 2100
% 2100 2100
% 2645 2645
% 2645 2645
% 3920 3920
% 3920 3920
% 1415 1415
% 1415 1415
% 1595 1595
% 1595 1595
% 2100 2100
% 2100 2100
% 2645 2645
% 2645 2645
% 3920 3920
% 3920 3920
1 Min. End
Length
RS
Typical RS
rim joist installation
CMST similar
Factored Resistance
1
Allowable Tension
DF-L (kN)
SPF (Lbs)
SPF (kN)
3
2 1/4
3/4
1 1/2
3 Typ.
6.29
6.29
7.10
7.10
9.34
9.34
9.34
9.34
11.77
11.77
17.44
17.44
6.29
6.29
7.10
7.10
9.34
9.34
11.77
11.77
17.44
17.44
1390
1295
1595
1500
2010
2010
2010
2010
2645
2610
3565
3605
1390
1295
1595
1500
2010
2010
2645
2610
3565
3605
1415
1415
1595
1595
2100
2100
2100
2100
2645
2645
3920
3920
1415
1415
1595
1595
2100
2100
2645
2645
3920
3920
6.18
5.76
7.10
6.67
8.94
8.94
8.94
8.94
11.77
11.61
15.86
16.04
6.18
5.76
7.10
6.67
8.94
8.94
11.77
11.61
15.86
16.04
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Fasteners to be installed with equal fasteners at each end of the connection.
3) 16d sinker nails may be substituted for 10d nails with no load reduction.
4) Minimum nail embedment shall be 8 nail diameters (typ).
5) NAILS:
%$ % %$
%
%$
%
#"! "!"!! ! red font.
76
3/4
6.29
6.29
7.10
7.10
9.34
9.34
9.34
9.34
11.77
11.77
17.44
17.44
6.29
6.29
7.10
7.10
9.34
9.34
11.77
11.77
17.44
17.44
CMSTC16
3
1 1/2
1
1 3/4
3 1/2
CMST
1-800-328-5934 www.USPconnectors.com
Installation:
Use all specified fasteners. See Product Notes,
page 10.
For safety, always wear gloves when handling or
cutting coiled strapping.
CMST installations: Install to a minimum 2 ply 2x
edge. Increase nail spacing if wood begins to split.
Designer may specify alternate nailing schedules. Refer
to Nail Specification table on page 14 for nail shear
values. Load values shall not exceed published factored
resistance.
3/8
End
Length
Optional nails
(wood shrinkage
may occur and
cause strap to
buckle outward)
KSTI 2 1/16 wide strapping. Straps are designed for installation to wood I-Joist flanges.
New
3
1 1/2
HTP37-TZ
1 1/4
4 1/2
3 3/4
2 1/16
New
1 1/2
KSTI226 26
KSTI236 36
KSTI248 48
KSTI260 60
KSTI272 72
3 14
1 1/2
1 1/2
KST29 9 7/16
KST213 12 11/16
KST216 15 15/16
KST218 19 3/16
KST224 22 7/16
KST234 32 3/16
2 1/16
2 1/16
KST227 27
KST237 37 1/2
KST248 48
KST260 60
KST272 72
3/8
typ.
KST scalloped
design
KST
straight edge
design
1 1/4
3/4
LSTI49 49
LSTI73 73
1 1/2
HRS
HRS8
HRS6
16 5/16
ST9 9
ST12 11 5/8
ST18 17 3/4
ST22 21 5/8
New
LSTA/MSTA 9
LSTA/MSTA 12
LSTA/MSTA 15
LSTA/MSTA 18
LSTA/MSTA 21
LSTA/MSTA 24
LSTA/MSTA 30
LSTA/MSTA 36
MSTA 48
1 3/8
HRS416-TZ
MSTC28 28 1/4
MSTC40 40 1/4
MSTC52 52 1/4
MSTC66 65 3/4
MSTC78 77 3/4
HRS12
Strap Ties HRS, HTP, KST, KSTI, LSTA, LSTI, MSTA, MSTC & ST series
LSTA/MSTA
KSTI
MSTC
1-800-328-5934 www.USPconnectors.com
LSTI
KST116
ST
USP2240-131
77
Strap Ties HRS, HTP, KST, KSTI, LSTA, LSTI, MSTA, MSTC & ST series cont.
Installation:
Use all specified fasteners. See Product Notes, page 10.
Designer may specify alternate nailing schedules. Refer to Nail Specification table on
page 14 for nail shear values. Load values shall not exceed published factored
resistance. The quantity of nails installed shall be equally distributed to both ends of
the strap.
The quantity of nails installed shall be equally distributed to both ends of the strap.
Dimensions (in)
Steel
Gauge
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
16
16
16
16
16
16
16
16
16
16
W
3/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-3/4
1-3/4
1-3/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
3-3/4
3-3/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-3/4
1-3/4
3
L
16-5/16
9
12
15
18
21
24
9-7/16
12-11/16
15-15/16
30
36
9
12
15
18
21
24
49
73
9
11-5/8
17-3/4
21-5/8
30
36
48
19-3/16
22-7/16
7
MSTC28
16
28-1/4
MSTC40
MSTC40
16
40-1/4
MSTC52
MSTC52
16
52-1/4
USP
Stock No.
KST116
LSTA9
LSTA12
LSTA15
LSTA18
LSTA21
LSTA24
KST29
KST213
KST216
LSTA30
LSTA36
MSTA9
MSTA12
MSTA15
MSTA18
MSTA21
MSTA24
LSTI49
LSTI73
ST9
ST12
ST18
ST22
MSTA30
MSTA36
MSTA48
KST218
KST224
HTP37-TZ
Ref. No.
ST2115
LSTA9
LSTA12
LSTA15
LSTA18
LSTA21
LSTA24
ST292
ST2122
ST2215
LSTA30
LSTA36
MSTA9
MSTA12
MSTA15
MSTA18
MSTA21
MSTA24
LSTI49
LSTI73
ST9
ST12
ST18
ST22
MSTA30
MSTA36
MSTA49
ST6215
ST6224
HTP37Z
MSTC28
1,5
Fastener Schedule
Total
Qty3
10
8
10
12
14
16
18
14
18
22
22
26
8
10
12
14
16
18
32
48
8
10
14
18
22
26
32
26
30
20
36
36
52
52
70
70
Min
Qty4
8
8
10
12
14
16
16
14
18
18
22
22
8
10
12
14
16
18
32
48
8
10
14
18
22
26
26
26
30
20
36
34
52
46
60
52
Type
16d
10d
10d
10d
10d
10d
10d
16d
16d
16d
10d
10d
10d
10d
10d
10d
10d
10d
10d x 1-1/2
10d x 1-1/2
16d
16d
16d
16d
10d
10d
10d
16d
16d
10d x 1-1/2
10d
16d
10d
16d
10d
16d
Factored Resistance
Uplift 115%
DF-L (Lbs)
995
1085
1355
1630
1855
1855
1855
1320
2680
2680
2460
2460
1085
1355
1630
1900
2170
2445
4340
6515
1325
1655
2095
2095
2985
3100
3070
2640
4440
2330
4380
6295
6570
7795
7795
7795
DF-L (kN)
4.43
4.83
6.03
7.25
8.25
8.25
8.25
5.87
11.92
11.92
10.94
10.94
4.83
6.03
7.25
8.45
9.65
10.88
19.31
28.98
5.89
7.36
9.32
9.32
13.28
13.79
13.66
11.74
19.75
10.36
19.48
28.00
29.23
34.68
34.68
34.68
S-P-F (Lbs)
940
775
970
1165
1360
1555
1555
940
2110
2110
2140
1945
775
970
1165
1360
1555
1750
3090
4635
1100
1375
1925
2095
2140
2525
2525
1875
3520
2110
3110
4435
4665
6305
6220
7795
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) Total number of nail and/or bolt holes provided in the strap.
4) Minimum quantity of fasteners to be installed with equal fasteners at each end of the connection. Product
may have additional nail holes not needed to meet published allowable load of product.
! ! !" $!
6) NAILS:# $# $ $#
$
$#
$
New products or updated product information are designated in red font.
78
USP
KST234
MSTC66
14
14
1-800-328-5934
www.USPconnectors.com
Min
Total
Steel
ST6236
S-P-F (kN)
4.18
3.45
4.31
5.18
6.05
6.92
6.92
4.18
9.39
9.39
9.52
8.65
3.45
4.31
5.18
6.05
6.92
7.78
13.75
20.62
4.89
6.12
8.56
9.32
9.52
11.23
11.23
8.34
15.66
9.39
13.83
19.73
20.75
28.05
27.67
34.68
1-3/4
3
32-3/16
65-3/4
42
36
16d
5665
25.20
4225
18.79
88
72
10d
9945
44.24
8165
36.32
Strap Ties HRS, HTP, KST, KSTI, LSTA, LSTI, MSTA, MSTC & ST series cont.
Fastener Schedule2,6
Dimensions (in)
Steel
Gaug
e
14
W
1-3/4
L
32-3/16
MSTC66
14
65-3/4
MSTC78
MSTC78
14
77-3/4
HRS6
HRS6
12
1-3/8
HRS8
HRS8
12
HRS12
HRS12
Total
Qty3
42
Factored Resistance1,5
Uplift 115%
Min
Qty4
36
Type
16d
DF-L (Lbs)
5665
DF-L (kN)
25.20
S-P-F (Lbs)
4225
S-P-F (kN)
18.79
88
72
10d
9945
44.24
8165
36.32
88
62
16d
9945
44.24
9945
44.24
104
76
10d
9945
44.24
8550
38.03
104
66
16d
9945
44.24
9945
44.24
10d
815
3.63
580
2.58
1-3/8
10
10
10d
1355
6.03
970
4.31
12
1-3/8
12
14
14
10d
1900
8.45
1355
6.03
KST227
MST27,
S/MST27
12
2-1/16
27
34
26
16d
4290
19.08
3050
13.57
KST237
MST37,
S/MST37
12
2-1/16
37-1/2
48
38
16d
6270
27.89
4455
19.82
KST248
MST48,
S/MST48
12
2-1/16
48
62
50
16d
8110
36.08
5865
26.09
KSTI226
MSTI26
12
2-1/16
26
26
26
10d x 1-1/2
2985
13.28
2125
9.45
KSTI236
MSTI36
12
2-1/16
36
36
36
10d x 1-1/2
4340
19.31
3090
13.75
KSTI248
MSTI48
12
2-1/16
48
48
48
10d x 1-1/2
5970
26.56
4250
18.91
KSTI260
MSTI60
12
2-1/16
60
60
60
10d x 1-1/2
7600
33.81
5410
24.07
KSTI272
MSTI72
12
2-1/16
72
72
60
10d x 1-1/2
8110
36.08
6570
29.23
HRS416-TZ
HRS416Z
12
3-1/4
16
16
16
WS15-GC
4057
18.05
3329
14.81
KST260
MST60,
S/MST60
10
2-1/16
60
72
64
16d
10560
46.98
7505
33.39
KST272
MST72,
S/MST72
10
2-1/16
72
72
64
16d
10605
47.18
8445
37.57
USP
Stock No.
KST234
Ref. No.
ST6236
MSTC66
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) Total number of nail and/or bolt holes provided in the strap.
4) Minimum quantity of fasteners to be installed with equal fasteners at each end of the connection. Product may have
additional nail holes not needed to meet published allowable load of product.
! ! !" $!
6) NAILS:# $# $ $#
$
$#
$
New products or updated product information are designated in red font.
MSTC28
MSTC28
MSTC40
MSTC40
MSTC52
MSTC52
MSTC66
MSTC66
MSTC78
MSTC78
KST237
KST248
KST260
KST272
S/MST37
S/MST48
S/MST60
S/MST72
KSTI236
MSTI36
KSTI248
MSTI48
KSTI260
MSTI60
KSTI272
MSTI72
18
16
18
16
18
16
18
16
18
16
18
16
18
16
18
16
18
16
18
16
18
16
18
16
18
16
Uplift (115%)
Qty
Type
12
16
28
32
44
48
62
64
64
66
20
22
32
34
46
48
46
48
14
16
26
28
38
40
50
52
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
16d
16d
16d
16d
16d
16d
16d
16d
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
7.30
9.70
16.90
19.30
26.60
29.00
37.40
38.60
38.60
39.90
14.70
16.10
23.50
24.90
33.70
35.20
33.70
35.20
8.50
9.70
15.70
16.90
22.90
15.90
29.00
29.00
1155
1540
2700
3085
4240
4625
5975
6165
6165
6360
2340
2575
3745
3980
5380
5615
5380
5615
1355
1550
2520
2715
3685
3585
4845
5040
5.10
6.90
12.00
13.70
18.90
20.60
26.60
27.40
27.40
28.30
10.40
11.50
16.70
17.70
23.90
25.00
23.90
25.00
6.00
6.90
11.20
12.10
16.40
15.90
21.60
22.40
Optional nails
(wood shrinkage may
occur and cause strap
to buckle outward)
1-800-328-5934 www.USPconnectors.com
End length
Clear
span
End length
USP
Stock No.
Factored Resistance1
Fasteners Total2,3
1 Min.
Typical KST237
floor-to-floor installation
USP2240-131
79
2,4
Dimensions (in)
USP
Stock No.
Steel
Ref. No. Gauge
KRPS18
KRPS22
KRPS28
RPS18
RPS22
RPS28
16
16
16
1,3
S-P-F
DF-L
Notch
Width
Qty
Type
Lbs
kN
Lbs
kN
18-5/16 $
22-5/16 < $
28-5/16 < $
12
16
16
16d
16d
16d
1375
1785
1785
6.12
7.94
7.94
1185
1535
1535
5.27
6.83
6.83
1-1/2
1-1/2
1-1/2
Fastener Schedule
Installation:
Use all specified fasteners. See Product Notes, page 10.
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
" $!
4) NAILS:
$#
$
New products or updated product information are designated in red font.
1 1/2
KRPS
NEW
SIZE
Minimum
(2) 2x or 4x
W
Stud
Fastening
Minimum
Length 22
Installation:
Use all specified fasteners. See Product
Notes, page 10.
No Nails
Required
Face Nailing
3 Minimum
Bearing Area
Typical MSTC66B3
installation
Sideview
Dimensions (in)
USP
Stock No.
MSTC48B3
MSTC66B3
80
Steel
Gauge
Ref. No.
MSTC48B3
14
MSTC66B3
14
Minimum
Beam
Dimensions
(in)
Fastener Schedule2,7
Beam
Face
Stud/Post
Tension
Bottom
DF-L
Lbs.
W
3
3
L
B
44-7/8 2-7/8
62-7/8 2-7/8
W
3
3
D
9-1/4
11-1/4
Qty
12
14
Type
10d
10d
Qty
4
4
Type
10d
10d
Qty
24
24
MSTC66B3
Factored Resistance
3,5,6
Type
10d
10d
kN
S-P-F
Lbs.
kN
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) Minimum strap length on stud/post for quantity of nails is 19" for MSTC48B3 and 22" for MSTC66B3.
4) The 3" wide beam may be double for 2x members.
5) Fewer fasteners in the stud/post than listed will reduce the capacity of the connection.
6) Nails in the stud/post to be installed symmetrically in pairs starting a minimum of 1-1/2" from the end.
7) NAILS:
New products or updated product information are designated in red font.
1-800-328-5934 www.USPconnectors.com
Materials: 16 gauge
Finish: G90 galvanizing
Options: KRPS22 and KRPS28 are is available in
Triple Zinc. To order, add TZ to stock
number, as in KRPS22-TZ.
Installation:
Use all specified fasteners. See Product Notes, page 10.
Consult I-Joist manufacturer for web stiffener
requirements, and uplift limitations on joist and application.
Uplift
8 3/8
19 1/8
2 1/4
6 1/2
LFTA6
L1
L
1 Typ.
1
Typ.
L2
1 1/4
1 1/4
LTW12/MTW12
LTW18/MTW18
other models similar
USP2240-131
F1
Place strap so all
nail holes align
with rim joist
Uplift
81
Dimensions (in)
USP
6
Stock No.
Steel
Gauge
DF-L
L
L1
L2
LTS12
18
1-1/4
12
4-1/2
4-1/2
LTW16
LTS16
18
1-1/4
16
6-1/2
6-1/2
LTW18
LTS18
18
1-1/4
18
7-1/2
7-1/2
LTW20
LTS20
18
1-1/4
20
8-1/2
8-1/2
KTS9
KTS12
TS9
TS12
16
16
1-1/4
1-1/4
9
11-1/2
-- --- --
-- --- --
MTW12
MTS12
16
1-1/4
12
4-1/2
4-1/2
MTW16
MTS16
16
1-1/4
16
6-1/2
6-1/2
KTS17
TS18
16
1-1/4
17-1/2
-- --
-- --
MTW18
MTS18
16
1-1/4
18
7-1/2
7-1/2
16
2-1/4
19-1/8
8-3/8
6-1/2
MTW20
MTS20
16
1-1/4
20
8-1/2
8-1/2
KTS24
TS22
16
1-1/4
21-3/4
-- --
-- --
MTW24C
MTS24C
16
1-1/4
24
10-7/16 10-7/16
MTW28C
-- --
16
1-1/4
28
12-7/16 12-7/16
MTW30
MTS30
16
1-1/4
30
8-5/16
MTW30C
MTS30C
16
1-1/4
30
13-7/16 13-7/16
HTW16
HTS16
14
1-1/4
16
5-1/8
5-1/8
HTW20
HTS20
14
1-1/4
20
7-1/8
7-1/8
HTW24
HTS24
14
1-1/4
24
9-1/8
9-1/8
HTW28
HTS28
14
1-1/4
28
11-1/8
11-1/8
HTW30
HTS30
14
1-1/4
30
17-1/4
HTW30C
HTS30C
14
1-1/4
30
12-1/8
12-1/8
18-9/16
Qty
12
12
12
12
12
12
12
12
8
10
14
14
14
14
14
14
14
16
16
14
14
18
14
14
14
14
14
14
14
14
16
16
24
20
24
20
24
20
24
20
24
20
Type
10d x 1-1/2
10d
10d x 1-1/2
10d
10d x 1-1/2
10d
10d x 1-1/2
10d
16d
16d
10d x 1-1/2
10d
10d x 1-1/2
10d
16d
10d x 1-1/2
10d
8d
8d x1-1/2
10d x 1-1/2
10d
16d
10d x 1-1/2
10d
10d x 1-1/2
10d
10d x 1-1/2
10d
10d x 1-1/2
10d
10d x 1-1/2
10d
10d x 1-1/2
10d
10d x 1-1/2
10d
10d x 1-1/2
10d
10d x 1-1/2
10d
10d x 1-1/2
10d
Lbs
1465
1465
1465
1465
1465
1465
1465
1465
915
1145
2250
2250
2250
2250
1370
2250
2250
1265
1265
2250
2250
1580
2250
2250
2250
2250
2250
2250
2250
2250
2340
2340
2880
2880
2880
2880
2880
2880
2880
2880
2880
2880
S-P-F
kN
6.52
6.52
6.52
6.52
6.52
6.52
6.52
6.52
4.07
5.09
10.01
10.01
10.01
10.01
6.09
10.01
10.01
5.63
5.63
10.01
10.01
7.03
10.01
10.01
10.01
10.01
10.01
10.01
10.01
10.01
10.41
10.41
12.81
12.81
12.81
12.81
12.81
12.81
12.81
12.81
12.81
12.81
Lbs
1040
1040
1040
1040
1040
1040
1040
1040
785
985
1595
1595
1595
1595
1175
1595
1595
1075
1075
1595
1595
1580
1595
1595
1595
1595
1595
1595
1595
1595
1660
1660
2045
2045
2045
2045
2045
2045
2045
2045
2045
2045
kN
4.63
4.63
4.63
4.63
4.63
4.63
4.63
4.63
3.49
4.38
7.10
7.10
7.10
7.10
5.23
7.10
7.10
4.78
4.78
7.10
7.10
7.03
7.10
7.10
7.10
7.10
7.10
7.10
7.10
7.10
7.38
7.38
9.10
9.10
9.10
9.10
9.10
9.10
9.10
9.10
9.10
9.10
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) 16d sinker nails may be substituted for 10d common nails with no reduction in load.
&(
.#+$(+)&*##&&( %"#)%&( %"#)
5) Fasteners shall be distributed equally on each end of the connection.
6) C after the model number designates center twist as in MTW30C.
")#)%
#)&!", #*(##&)*!(%"#)$+)*"%)*##&%!)"&%*!)*('#&*
closest to the bend line. Lateral F1 and F2 load directions do not apply to roof truss-to-top plate installations.
8) NAILS:-
%"#)( ."-
.#&% %"#)( ."-
.#&% -
.%"#)( ."-
.#&%
%"#)( ."-.#&% %"#)(
."-
.#&%
New products or updated product information are designated in red font.
Typical MTW20
I-Joist Rafter
installation
Typical MTW30
installation
L1
L1
L
L2
L2
1 1/4
1 1/4
KTS
82
1-800-328-5934 www.USPconnectors.com
MTW30C
MTW30/
HTW30
LTW12
LFTA6
Ref. No.
cont.
Materials: 20 gauge
Finish: G90 galvanizing
Load direction
Installation:
Use all specified fasteners. See Product Notes, page 10.
Centre strap on top plate over the stud.
Attach centre nail and bend inside end of strap downward.
Install nails on inside of wall.
Install floor system or place manufactured home on foundation.
Form outside end of strap up the outside of rim and install nails.
Typical PWFS24
installation
1 1/2
Dimensions (in)
USP
Stock No.
PWFS24
Steel
Ref. No. Gauge
PWF24
20
Fastener Schedule1,3
W
1-1/2
L
24
Qty
9
Type
8d
Lbs
1115
S-P-F
kN
4.96
Lbs
930
kN
4.14
24
PWFS24
Angles & Straps
1-800-328-5934 www.USPconnectors.com
USP2240-131
83
NEW
SIZE
1 1/ 2
5/8
L
L
3 minimum
3 minimum
3 minimum
3 minimum
1/2
12 1/212
minimum
minimum
Typical MSTCM40
installation
Typical MSTAM36
installation
Dimensions (in)
Concrete
Uplift (115%)
Nails
DF-L
W
1-1/4
1-1/4
L
24
36
Qty
5
8
Type
5+*)
5+*)
Qty
5
8
Type
5+*)
5+*)
16
40-1/4
14
5+*)
14
5+*)
MSTCM60
16
60
14
5+*)
14
5+*)
Qty
9
10
24
22
24
22
Type
10d
10d
10d
16d
10d
16d
Fastener Schedule
1
CMU
USP
Stock No.
MSTCM60
Clear
Span
16
18
16
18
16
18
Concrete
Nails
kN
10.30
12.99
Lbs
2315
2820
kN
10.30
12.54
6905
30.72
4905
21.82
6905
30.72
4905
21.82
Factored Resistance3
Uplift (115%)
DF-L
Qty
5
5
14
14
14
14
Type
5+*)
5+*)
5+*)
5+*)
5+*)
5+*)
Qty
5
5
14
14
14
14
Type
5+*)
5+*)
5+*)
5+*)
5+*)
5+*)
Qty
8
7
14
14
22
22
Type
10d
10d
16d
16d
16d
16d
Lbs
1825
1825
4700
4700
6905
6905
kN
8.12
8.12
20.91
20.91
30.72
30.72
S-P-F
Lbs
1445
1445
4380
4380
4905
4905
kN
6.43
6.43
19.48
19.48
21.82
21.82
.!0%' !3
53
5+*)"./!)!-.*-!,0'%)./''! %)*- )!2%/$
/$!()0"/0-!-..+!%"%/%*)
%)%(0()%'!(! (!)/.$''!)%' %(!/!-./4+
/*-! -!.%./)!.-! !-%1! "-*(/!./.+!-"*-(! 0.%)#$*''*2 *)-!/!'*&
!2+-* 0/.*-0+ /! +-* 0/%)"*-(/%*)-! !.%#)/! %) red font.
84
S-P-F
Lbs
2315
2920
/*-! !.%./)!.-! !-%1! "-*(/!./.+!-"*-(! 0.%)#$*''*2 *)-!/!'*&
%)%(0()%'!(! (!)/.$''!)%' %(!/!-./4+
.!0%' !3
53
5+*)"./!)!-.*-!,0'%)./''! %)*- )!2%/$()0"/0-!-..+!%"%/%*)
!2+-* 0/.*-0+ /! +-* 0/%)"*-(/%*)-! !.%#)/! %) red font.
MSTCM40
Factored Resistance1
CMU
Steel
Ref. No. Gauge
MSTAM24
18
MSTAM36
16
Fastener Schedule
3
USP
Stock No.
MSTAM24
MSTAM36
3
3
14 14
minimum
minimum
1-800-328-5934 www.USPconnectors.com
MSTAM36
Installation:
Use all specified fasteners. See Product Notes, page 10.
Materials: 14 gauge
Finish: G90 galvanizing
Codes: Load values are derived from data submitted
to various North American building code
evaluators.
Installation Instructions:
Use all specified fasteners. See Product Notes pages 10.
Strap may be attached to either side of grouted masonry or
concrete wall with a minimum of (1) #5 horizontal rebar.
Drill hole in concrete or masonry with manufacturers
prescribed 3/16 masonry drill. Install fasteners into concrete or
masonry per manufacturers specification.
Grout or concrete compressive strength shall be 2,000 psi at
28 days.
Twist straps do not have to be wrapped over the truss to
achieve the factored resistance.
Moisture barrier may be required.
Typical HTWM
installation
L1
L1
W
HTWM
Factored Resistance1
Fastener Schedule
CMU2
Concrete2
Dimensions (in)
Truss/Rafter2,3
Uplift (115%)
DF-L
USP
Steel
Nail
Stock No.
Gauge W
Type
Ref. No.
L
L1
Qty Wedge Bolts Qty Wedge Bolts Qty
Lbs
kN
Lbs
HTWM16
HTSM16, MTSM16
14
1-1/4 16 5-3/4
4
., .
4
., .
8 ,
6.76
1335
14
1-1/4
7-3/4
4
., .
4
., .
8 ,
6.76
1335
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
($+'(()#'( ., .$!)-$'&*! #()!! #$'#+ )"#*)*''((% ) $#
3) NAILS: ,
# !(' . ,
.!$#
1-800-328-5934 www.USPconnectors.com
S-P-F
kN
5.94
5.94
USP2240-131
85
Hangers
Hanger Selector Guide . . . . . . . . . . Page 87
Face Mount Joist Hangers . . Pages 88-96
ST
SUH
HD
JL
DT
JUS
MUS
JLIF
HUS
HDQIF
KLB Series
Light-capacity 14 gauge top mount hanger with uplift capacity.
KB Series
Medium-capacity 12 gauge top mount hanger with uplift capacity.
HDO Series
Medium-capacity 12 gauge top mount hanger with uplift capacity.
SW Series
Light-capacity welded hanger with primer finish.
SWH Series
Medium-capacity welded hanger with primer finish.
KHW Series
Heavy-capacity welded hanger with primer finish.
HL Series
Light-capacity 18 gauge 2x top mount hanger.
JH Series
Medium-capacity strap style hanger.
KLB
KB
SWH
KHW
HL
JH
LSSH
SKH
SKHH
LS
HWUH
MPH
UMH
HDO
SW
Hangers
86
LSSH Series
Field adjustable slope and skew hanger.
SKH Series
Light-capacity 45 skewed hanger.
SKHH Series
Medium-capacity 45 skewed hanger.
LS Series
Light-capacity hanger for slopes from 0 up to 30 down.
1-800-328-5934 www.USPconnectors.com
ST Series
Light-capacity 22 gauge joist hanger.
DT Series
Light-capacity 22 gauge joist hanger.
JL Series
Light-capacity 20 gauge joist hanger.
JLIF Series
Inverted flange 18 gauge joist hanger.
SUH Series
Medium-capacity 16 gauge joist hanger.
JUS Series
Medium-capacity 18 gauge joist hanger with slant nailing.
MUS Series
Medium-capacity 18 gauge joist hanger with slant nailing.
HUS Series
Heavy-capacity 14 or 16 gauge joist hanger with slant nailing.
HD Series
Heavy-capacity 14 gauge joist hanger.
HDQIF Series
Inverted flange 14 gauge joist hanger.
Hangers
FHD26
Medium-capacity purlin saddle hanger.
JPF Series
Medium-capacity purlin hanger with double shear nailing.
JDS Series
Medium-capacity purlin saddle hanger.
DTUS & TUS Series
Medium-capacity 16 gauge joist hanger.
FHD26
JDS
JPF
TUS
DTUS
-- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --
4,760
3,235
-- --
-- --
7,625 - 7,680
5,185 - 5,225
-- --
-- --
1,830 - 2,290
3,565 - 4,750
1,370 - 1,765
1,340 - 2,775
2,985 - 5,230
825 - 5,065
2,575 - 7,405
2,175 - 5,240
785 - 2,735
1,575
1,755 - 1,995
980
980
1,245 -1,925
2,745 - 3,375
1,180 - 1,520
950 - 1,970
2,120 - 3,715
585 - 3,595
1,830 - 5,260
1,880 - 4,530
560 - 1,940
1,120
1,245 - 1,420
695
695
-- --- --
-- --- --
-- --
-- --
5,010 - 8,625
3,555 - 6,125
-- --- --
-- --- --
3,745 - 6,165
11,875
3,220 - 5,300
8,430
Masonry
-- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --
Glulam
670 - 1,520
1,380 - 1,640
689 - 2,180
1,122 - 3,671
2,305 - 3,125
475 - 1,305
985 - 4,070
3,891 - 6,408
1,512 - 4,505
1,090 - 5,194
3,775 - 6,005
1,585
2,960 - 3,605
2,625 - 6,625
2,265 - 2,470
Truss
SPF Masonry
670 - 1,520
1,380 - 1,640
970 - 3,070
1,580 - 5,170
3,245 - 4,400
670 - 1,835
1,390 - 5,730
5,480 - 9,025
2,130 - 6,345
1,535 - 7,315
5,315 - 8,460
2,235
4,165 - 5,075
3,125 - 7,885
3,335 - 3,630
EWP
Dimensional Wood
Truss
DF-L Masonry
EWP
Formed
Glulam
SPF
Masonry
1-800-328-5934 www.USPconnectors.com
USP2240-131
Hangers
Panel and
Purlin
DF-L
Slope
and
Skew
Dimensional Wood
Top
Mount
Steel
Gauge
22
22
20
18
18
18
16
16
HUS
14
HD
14
HDQIF
14
KLB
14
KB
12
HDO
12
SW
12
7 - Top Flange
SWH
12 - Stirrup
3 - Top Flange
KHW
10 - Stirrup
HL
18
JH
18
LS
18
18
LSSH
16
16
SKH
14
SKHH
14
JDS
18
FHD
18
JPF
20
DTUS
20
TUS
20
1/4"- Top Flange,
HWUH
7 - Stirrup
MPH
12
1
1/4"
UMH
Welded
Face
Mount
USP
Series
ST
DT
JL
JUS
MUS
JLIF
SUH
Sloped / Skewed
Hanger
Type
Top Mount
Header Material
Face Mount
87
Installation:
Use all specified fasteners. See Product Notes, page 10.
Factored
Resistance
Ordering
Skewed1,3
WR
when width is
RUOHVV
WRRQDOORWKHUV
100% of table value.
RIXSOLIWYDOXH
on skews greater
WKDQ
Add SK angle required,
and right (R) or left (L),
to product number.
Ex. SUH210-SK45R
Sloped Seat2,3
Sloped / Skewed1,2,3
WR
Typical SUH26-2
installation
A
JL26
Typical ST
installation
SUH26-2
Typical DT
installation
A
ST
DT
1) Skewed hangers with skews greater than 15 may have all joist nailing on outside flange.
2) Sloped or sloped / skewed hangers with slopes greater than 15 may have additional joist nails.
3) All sloped, skewed, or combinations require bevel cut on joist in all applications and web stiffeners with I-Joists.
4) Some SUH option hangers may be manufactured as welded products to achieve listed values.
Hangers
Typical JLIF
installation
88
JLIF
1-800-328-5934 www.USPconnectors.com
Typical JL26
installation
The HUS, JUS, & MUS hanger series offers double shear nailing. USPs dimple allows for
30 to 45 nailing through the joist into the header resulting in higher loads and less
nailing. Slant nailing also eliminates the need for shorter joist nails in 2x applications.
Installation:
Use all specified fasteners. See Product Notes, page 10.
Joist nails must be driven at a 30 to 45 angle through the joist or truss into the
header to achieve listed loads. Standard length double shear nails must be used to
achieve listed load values.
JUS & MUS 16d sinkers (9 gauge x 314 ) may be used where 10d commons are
specified with no load reduction.
Typical JUS46
installation
A
Dimple
allows 30
to 45
nailing
D
JUS28
Uses standard
length nails
MUS
HUS Specialty Options Chart
refer to Specialty Options pages
210 to 211 for additional details.
Option
Range
Factored
Resistance
Ordering
Inverted Flange
Not available in
# %
"!
65% of table value when
nailing into the support
Add IF
! !
$
Typical HUS46
installation
1-800-328-5934 www.USPconnectors.com
HUS28-2
Hangers
Typical HUS410IF
inverted flange installation
USP2240-131
89
Installation:
Use all specified fasteners. See Product Notes, page 10.
Some HD models feature nail holes along bend line that must
be filled to achieve factored resistance. Verify proper
header width to accomplish this for inverted models.
Typical HD210-2
installation
Typical HD610
installation
A
Bend line
nailing
D
W
HD610
Typical HD3212
glulam installation
Inverted Flange
Skewed1,3
Sloped Seat2,3
Sloped / Skewed1,2,3
when width is
See Sloped Seat and
Not available in
Range
Skewed
100% of table value.
80% of table value.
100% of table value.
75% of uplift value
75% of uplift value
65% of table value when
Factored
100% of table value
Resistance
on skews greater
on skews greater
nailing into the support
members end grain.
Add SK, angle required, Add SL, slope required,
Add IF
See Sloped Seat and
and right (R) or left (L), and up (U) or down (D),
Ordering
to product number.
Skewed.
to product number.
to product number.
Ex. HD410IF
Ex. HD410-SK45RSL30D
Ex. HD410-SK45R
Ex. HD410-SL30D
1) Skewed hangers with skews greater than 15 may have all joist nailing on outside flange.
2) Sloped or sloped / skewed hangers with slopes greater than 15 may have additional joist nails.
3) All sloped, skewed, or combinations require bevel cut on joist in all applications and web stiffeners with I-joists.
4) Modifications of HD hangers may be manufactured as hot rolled, welded, or primed.
Typical HD210-2IF
inverted flange
installation
HD51135
Hangers
Installation:
Use all specified fasteners. See Product Notes, page 10.
WS15 and WS3 WoodScrews are supplied with HDQIF hangers.
90
HDQIF
1-800-328-5934 www.USPconnectors.com
Up to
gap
3/4
Typical HDQIF
installation
Materials: 14 gauge
Finish: G90 galvanizing
Options: HD28-2IF, HD210-2IF, HD210-3IF, HD44IF,
HD46, HD46IF, HD48, HD48IF, HD410,
HD410IF, HD412, HD412IF, HD68, HD68IF,
HD610, HD610IF, HD612 & HD612IF are
available in Triple Zinc. To order, add TZ to
stock number, as in HD28-2IFTZ.
HD210-2IF is available in Stainless Steel. To
order, add SS to stock number,
as in HD210-2IFSS.
All nominal lumber sizes are available
rough/full size lumber. See Specialty Options
Chart.
Codes: Load values are derived from data submitted to
various North American building code
evaluators.
Dimensions (in)
Joist Size
2x4
2x6
2x8
2 x 10
2 x 12
USP
Stock No.
JL24
ST24
JL24IF-TZ
JUS24
JUS24-GC
SUH24
HD26
JL26
ST26
JL26IF-TZ
JUS26
JUS26-GC
MUS26
SUH26
HUS26
HD26
HD28
JL26
JL28
ST26
ST28
JL26IF-TZ
JL28IF-TZ
JUS26
JUS26-GC
JUS28
JUS28-GC
MUS26
MUS28
SUH26
SUH28
HUS26
HUS28
HD28
HD210
JL28
JL210
ST28
ST210
JL28IF-TZ
JL210IF-TZ
JUS28
JUS28-GC
JUS210
JUS210-GC
MUS28
SUH28
SUH210
HUS28
HUS210
HD210
JL210
ST210
JL210IF-TZ
JUS210
JUS210-GC
SUH210
HUS210
HD210
HD212
HD212IF
Ref. No.
LU24, LU24L
-- --- -LUS24
-- -U24
HU26
LU26, LU26L
-- -LUC26Z
LUS26
-- -MUS26
U26
HUS26
HU26
HU28
LU26, LU26L
LU28
-- --- -LUC26Z
-- -LUS26
-- -LUS28
-- -MUS26
MUS28
U26
-- -HUS26
HUS28
HU28
HU210
LU28
LU210
-- --- --- -LUC210Z
LUS28
-- -LUS210
-- -MUS28
-- -U210
HUS28
HUS210
HU210
LU210, LU210L
-- -LUC210Z
LUS210
-- -U210
HUS210
HU210
HU212
HUC212
Steel
Gauge
20
22
18
18
18
16
14
20
22
18
18
18
18
16
16
14
14
20
20
22
22
18
18
18
18
18
18
18
18
16
16
16
16
14
14
20
20
22
22
18
18
18
18
18
18
18
16
16
16
16
14
20
22
18
18
18
16
16
14
14
14
Factored Resistance
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
H
3
3-1/4
3-1/8
3-1/8
3-1/8
3-1/4
3-1/2
4-3/4
5
4-1/2
4-13/16
4-13/16
5-1/16
5-1/8
5-7/16
3-1/2
5-1/4
4-3/4
6-3/8
5
6-3/4
4-1/2
6-1/8
4-13/16
4-13/16
6-5/8
6-5/8
5-1/16
7-1/16
5-1/8
6-5/8
5-7/16
7-3/16
5-1/4
7-3/16
6-3/8
8-1/4
6-3/4
8
6-1/8
8-7/32
6-5/8
6-5/8
7-3/4
7-3/4
7-1/16
6-5/8
8
7-3/16
9-3/16
7-3/16
8-1/4
8
8-7/32
7-3/4
7-3/4
8
9-3/16
7-3/16
9-1/4
9-1/4
D
1-1/2
1-7/8
1-1/2
1-3/4
1-3/4
2
2
1-1/2
1-7/8
1-1/2
1-3/4
1-3/4
2
2
3
2
2
1-1/2
1-1/2
1-7/8
1-7/8
1-1/2
1-1/2
1-3/4
1-3/4
1-3/4
1-3/4
2
2
2
2
3
3
2
2
1-1/2
1-1/2
1-7/8
1-7/8
1-1/2
1-1/2
1-3/4
1-3/4
1-3/4
1-3/4
2
2
2
3
3
2
1-1/2
1-7/8
1-1/2
1-3/4
1-3/4
2
3
2
2
2
A
15/16
1-1/4
-- -1
1
1-3/16
1-1/8
15/16
1-1/4
-- -1
1
1
1-3/16
2
1-1/8
1-1/8
15/16
15/16
1-1/4
1-1/4
-- --- -1
1
1
1
1
1
1-3/16
1-3/16
2
2
1-1/8
1-1/8
15/16
15/16
1-1/4
1-1/4
-- --- -1
1
1
1
1
1-3/16
1-3/16
2
2
1-1/8
15/16
1-1/4
-- -1
1
1-3/16
2
1-1/8
1-1/8
-- --
Qty
4
4
4
4
4
4
4
6
6
6
4
4
6
6
14
4
8
6
10
6
8
6
8
4
4
6
6
6
8
6
8
14
22
8
12
10
14
8
10
8
11
6
6
8
8
8
8
10
22
30
12
14
10
11
8
8
10
30
12
16
16
Type
10d
10d x 1-1/2
10d HDG
10d
N10C-GC
10d
16d
10d
10d x 1-1/2
10d HDG
10d
N10C-GC
10d
10d
16d
16d
16d
10d
10d
10d x 1-1/2
10d x 1-1/2
10d HDG
10d HDG
10d
N10C-GC
10d
N10C-GC
10d
10d
10d
10d
16d
16d
16d
16d
10d
10d
10d x 1-1/2
10d x 1-1/2
10d HDG
10d HDG
10d
N10C-GC
10d
N10C-GC
10d
10d
10d
16d
16d
16d
10d
10d x 1-1/2
10d HDG
10d
N10C-GC
10d
16d
16d
16d
16d
Qty
2
3
2
2
2
2
2
4
5
4
4
4
6
4
6
2
4
4
6
5
7
4
4
4
4
4
4
6
8
4
6
6
8
4
4
6
8
7
8
4
6
4
4
4
4
8
6
6
8
10
4
8
8
6
4
4
6
10
4
6
6
Type
100%
10d x 1-1/2
970
8d x 1-1/2
670
10d x 1-1/2 HDG 670
10d
1595
N10C-GC
1595
10d x 1-1/2
1390
10d x 1 1/2
1975
10d x 1-1/2
1430
8d x 1-1/2
1000
10d x 1-1/2 HDG 1000
10d
2855
N10C-GC
2855
10d
3245
10d x 1-1/2
2345
16d
5480
10d x 1 1/2
1975
10d x 1 1/2
2720
10d x 1-1/2
1430
10d x 1-1/2
2120
8d x 1-1/2
1000
8d x 1-1/2
1340
10d x 1-1/2 HDG 1000
10d x 1-1/2 HDG 1340
10d
2855
N10C-GC
2855
10d
2855
N10C-GC
2855
10d
3245
10d
4400
10d x 1 1/2
2345
10d x 1 1/2
2345
16d
5480
16d
7115
10d x 1 1/2
2720
10d x 1 1/2
3820
10d x 1-1/2
2120
10d x 1-1/2
3070
10d x 1-1/2
1340
10d x 1-1/2
1520
10d x 1-1/2 HDG 1340
10d x 1-1/2 HDG 1835
10d
2855
N10C-GC
2855
10d
2855
N10C-GC
2855
10d
4400
10d x 1-1/2
2345
10d x 1-1/2
4080
16d
7115
16d
9025
10d x 1 1/2
3820
10d x 1-1/2
3070
8d x 1-1/2
1520
10d x 1-1/2 HDG 1835
10d
2855
N10C-GC
2855
10d x 1-1/2
4080
16d
9025
10d x 1 1/2
3820
10d x 1 1/2
4545
10d x 1 1/2
4545
115%
460
370
380
960
960
795
545
915
620
755
2100
2100
1625
1505
3625
545
1555
915
1665
620
870
755
755
2100
2100
2100
2100
1625
2315
1505
1505
3625
4840
1555
1555
1665
2065
870
990
755
1135
2100
2100
2100
2100
2315
1505
2505
4840
6035
1555
2065
990
1135
2100
2100
2505
6035
1555
2005
2005
100%
4.31
2.98
2.98
7.10
7.10
6.18
8.79
6.36
4.45
4.45
12.70
12.70
14.44
10.43
24.38
8.79
12.10
6.36
9.43
4.45
5.96
4.45
5.96
12.70
12.70
12.70
12.70
14.44
19.57
10.43
10.43
24.38
31.65
12.10
16.99
9.43
13.66
5.96
6.76
5.96
8.16
12.70
12.70
12.70
12.70
19.57
10.43
18.15
31.65
40.15
16.99
13.66
6.76
8.16
12.70
12.70
18.15
40.15
16.99
20.22
20.22
115%
2.05
1.65
1.69
4.27
4.27
3.54
2.42
4.07
2.76
3.36
9.34
9.34
7.23
6.69
16.13
2.42
6.92
4.07
7.41
2.76
3.87
3.36
3.36
9.34
9.34
9.34
9.34
7.23
10.30
6.69
6.69
16.13
21.53
6.92
6.92
7.41
9.19
3.87
4.40
3.36
5.05
9.34
9.34
9.34
9.34
10.30
6.69
11.14
21.53
26.85
6.92
9.19
4.40
5.05
9.34
9.34
11.14
26.85
6.92
8.92
8.92
100%
689
670
475
1132
1132
985
1402
1015
1000
710
2027
2027
2305
1665
3891
1402
1931
1015
1505
1000
1340
710
950
2027
2027
2027
2027
2305
3125
1665
1665
3891
5052
1931
2712
1505
2180
1340
1520
950
1305
2027
2027
2027
2027
3125
1665
2895
5052
6408
2712
2180
1520
1305
2027
2027
2895
6408
2712
3227
3227
115%
327
370
270
682
682
565
387
650
620
535
1491
1491
1155
1070
2574
387
1104
650
1182
620
870
535
535
1491
1491
1491
1491
1155
1645
1070
1070
2574
3436
1104
1104
1182
1466
870
990
535
805
1491
1491
1491
1491
1645
1070
1780
3436
4285
1104
1466
990
805
1491
1491
1780
4285
1104
1424
1424
100%
3.06
2.98
2.11
5.04
5.04
4.38
6.24
4.52
4.45
3.16
9.02
9.02
10.25
7.41
17.31
6.24
8.59
4.52
6.69
4.45
5.96
3.16
4.23
9.02
9.02
9.02
9.02
10.25
13.90
7.41
7.41
17.31
22.47
8.59
12.06
6.69
9.70
5.96
6.76
4.23
5.81
9.02
9.02
9.02
9.02
13.90
7.41
12.88
22.47
28.51
12.06
9.70
6.76
5.81
9.02
9.02
12.88
28.51
12.06
14.35
14.35
115%
1.45
1.65
1.20
3.03
3.03
2.51
1.72
2.89
2.76
2.38
6.63
6.63
5.14
4.76
11.45
1.72
4.91
2.89
5.26
2.76
3.87
2.38
2.38
6.63
6.63
6.63
6.63
5.14
7.32
4.76
4.76
11.45
15.28
4.91
4.91
5.26
6.52
3.87
4.40
2.38
3.58
6.63
6.63
6.63
6.63
7.32
4.76
7.92
15.28
19.06
4.91
6.52
4.40
3.58
6.63
6.63
7.92
19.06
4.91
6.33
6.33
Hangers
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) 16d sinkers may be used at 0.84 of the table load where 16d commons are specified.
4) NAILS:!" "!"!"
"!"
"! ""! "
red font.
USP2240-131
91
continued
Fastener Schedule2,3,4
Dimensions (in)
Header
Joist Size
2 x 14
2 x 16
(2) 2 x 6
(2) 2 x 8
(2) 2 x 10
Hangers
(2) 2 x 12
Ref. No.
U214
HU212
HUC212
HU214
U214
HU212
HUC212
HU214
HU216
LUS24-2
U24-2
HU24-2
-- --- --- -LUS26-2
-- -U26-2
HU24-2
HUS26-2
HUSC26-2
HU26-2
HUC26-2
-- --- -LUS26-2
-- -LUS28-2
U26-2
-- -HUS26-2
HUSC26-2
HUS28-2
HUSC28-2
HU26-2
HUC26-2
HU28-2
HUC28-2
-- --- -LUS28-2
LUS210-2
-- --- -U210-2
HUS28-2
HUSC28-2
HU28-2
HUC28-2
HUS210-2
HUSC210-2
HU210-2
HUC210-2
HUCQ210-2-SDS
-- -LUS210-2
-- -U210-2
HUS210-2
HUSC210-2
HU210-2
HUC210-2
HUS212-2
HUSC212-2
HU212-2
HUC212-2
HUCQ210-2-SDS
Steel
Gauge
16
14
14
14
16
14
14
14
14
18
16
14
14
14
22
18
18
16
14
14
14
14
14
22
22
18
18
18
16
16
14
14
14
14
14
14
14
14
22
22
18
18
18
16
16
14
14
14
14
14
14
14
14
14
22
18
18
16
14
14
14
14
14
14
14
14
14
Factored Resistance
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
W
1-9/16
1-9/16
1-9/16
1-9/16
1-9/16
1-9/16
1-9/16
1-9/16
1-9/16
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/16
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/16
3-1/16
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/16
3-1/16
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/4
3-1/16
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/8
3-1/4
H
10
9-1/4
9-1/4
11-1/2
10
9-1/4
9-1/4
11-1/2
13-1/2
3-7/16
3-1/8
3-1/2
3-7/16
3-7/16
5
5-1/4
5-1/4
5-1/16
3-1/2
5-1/4
5-1/4
5-1/8
5-1/8
5
6-3/4
5-1/4
5-1/4
7-1/8
5-1/16
6-1/4
5-1/4
5-1/4
7-1/8
7-1/8
5-1/8
5-1/8
7-1/8
7-1/8
6-3/4
7-7/8
7-1/8
9-1/8
9-1/8
6-1/4
8-9/16
7-1/8
7-1/8
7-1/8
7-1/8
9-1/8
9-1/8
9
9
9
7-7/8
9-1/8
9-1/8
8-9/16
9-1/8
9-1/8
9
9
11-1/8
11-1/8
11
11
9
D
2
2
2
2
2
2
2
2
2
2
2
2-1/2
2
2
2
2
2
2
2-1/2
2
2
2-1/2
2-1/2
2
2
2
2
2
2
2
2
2
2
2
2-1/2
2-1/2
2-1/2
2-1/2
2
2
2
2
2
2
2
2
2
2-1/2
2-1/2
2
2
2-1/2
2-1/2
3
2
2
2
2
2
2
2-1/2
2-1/2
2
2
2-1/2
2-1/2
3
A
1-1/8
1-1/8
-- -1-1/8
1-1/8
1-1/8
-- -1-1/8
1-1/8
1
1-1/8
1-1/8
1
1
1-1/4
1
1
1-1/8
1-1/8
1
-- -1-1/8
1-1/8
1-1/4
1-1/4
1
1
1
1-1/8
1-1/8
1
-- -1
-- -1-1/8
1-1/8
1-1/8
-- -1-1/4
1-1/4
1
1
1
1-1/8
1-1/8
1
-- -1-1/8
-- -1
-- -1-1/8
-- -1-1/2
1-1/4
1
1
1-1/8
1
-- -1-1/8
-- -1
-- -1-1/8
-- -1-1/2
Qty
12
16
16
20
12
16
16
20
24
4
6
4
4
4
8
4
4
8
4
4
4
12
12
8
10
4
4
6
8
10
4
4
6
6
12
12
14
14
10
12
6
8
8
10
14
6
6
14
14
8
8
18
18
12
12
8
8
14
8
8
18
18
10
10
22
22
12
Type
10d
16d
16d
16d
10d
16d
16d
16d
16d
16d
10d
16d
16d
16d
16d x 2-1/2
16d
N16C-GC
10d
16d
16d
16d
16d
16d
16d x 2-1/2
16d x 2-1/2
16d
N16C-GC
16d
10d
10d
16d
16d
16d
16d
16d
16d
16d
16d
16d x 2-1/2
16d x 2-1/2
16d
16d
N16C-GC
10d
10d
16d
16d
16d
16d
16d
16d
16d
16d
WS3
16d x 2-1/2
16d
N16C-GC
10d
16d
16d
16d
16d
16d
16d
16d
16d
WS3
Qty
8
6
6
6
8
6
6
6
8
2
2
2
2
2
5
4
4
4
2
4
4
6
6
5
7
4
4
4
4
4
4
4
6
6
6
6
6
6
7
8
4
6
6
4
6
6
6
6
6
8
8
10
10
6
8
6
6
6
8
8
10
10
10
10
10
10
6
Type
10d x 1-1/2
10d x 1 1/2
10d x 1 1/2
10d x 1-1/2
10d x 1-1/2
10d x 1 1/2
10d x 1 1/2
10d x 1-1/2
10d x 1-1/2
16d
10d
10d
16d
16d
8d x 1-1/2
16d
N16C-GC
10d
10d
16d
16d
10d
10d
8d x 1-1/2
8d x 1-1/2
16d
N16C-GC
16d
10d
10d
16d
16d
16d
16d
10d
10d
10d
10d
8d x 1-1/2
8d x 1-1/2
16d
16d
N16C-GC
10d
10d
16d
16d
10d
10d
16d
16d
10d
10d
WS3
8d x 1-1/2
16d
N16C-GC
10d
16d
16d
10d
10d
16d
16d
10d
10d
WS3
100%
4105
4545
4545
5915
4105
4545
4545
5915
5915
1580
1910
1535
2130
2130
1380
2000
2000
3135
1535
2130
2130
3430
3430
1380
1510
2000
2000
3240
3135
3135
2130
2130
3795
3795
3430
3430
4675
4675
1510
1640
3240
5170
5170
3135
5730
3795
3795
4675
4675
5185
5185
7215
7215
8460
1640
5170
5170
5730
5185
5185
7215
7215
6345
6345
7215
7215
8460
115%
2505
2005
2005
2005
2505
2005
2005
2005
2005
610
825
535
935
935
620
2550
2550
1665
535
2095
2095
2685
2685
620
870
2550
2550
2550
1665
1665
2095
2095
3405
3405
2685
2685
2685
2685
870
990
2550
3735
3735
1665
2920
3405
3405
2685
2685
4165
4165
4435
4435
4970
990
3735
3735
2920
4165
4165
4435
4435
5765
5765
4435
4435
4970
100%
18.26
20.22
20.22
26.31
18.26
20.22
20.22
26.31
26.31
7.03
8.50
6.83
9.48
9.48
6.14
8.90
8.90
13.95
6.83
9.48
9.48
15.26
15.26
6.14
6.72
8.90
8.90
14.41
13.95
13.95
9.48
9.48
16.88
16.88
15.26
15.26
20.80
20.80
6.72
7.30
14.41
23.00
23.00
13.95
25.49
16.88
16.88
20.80
20.80
23.06
23.06
32.10
32.10
37.63
7.30
23.00
23.00
25.49
23.06
23.06
32.10
32.10
28.23
28.23
32.10
32.10
37.63
115%
11.14
8.92
8.92
8.92
11.14
8.92
8.92
8.92
8.92
2.71
3.67
2.38
4.16
4.16
2.76
11.34
11.34
7.41
2.38
9.32
9.32
11.94
11.94
2.76
3.87
11.34
11.34
11.34
7.41
7.41
9.32
9.32
15.15
15.15
11.94
11.94
11.94
11.94
3.87
4.40
11.34
16.61
16.61
7.41
12.99
15.15
15.15
11.94
11.94
18.53
18.53
19.73
19.73
22.11
4.40
16.61
16.61
12.99
18.53
18.53
19.73
19.73
25.65
25.65
19.73
19.73
22.11
100%
2915
3227
3227
4200
2915
3227
3227
4200
4200
1122
1355
1090
1512
1512
1380
1420
1420
2225
1090
1512
1512
2435
2435
1380
1510
1420
1420
2300
2225
2225
1512
1512
2694
2694
2435
2435
3319
3319
1510
1640
2300
3671
3671
2225
4070
2694
2694
3319
3319
3681
3681
5123
5123
6005
1640
3671
3671
4070
3681
3681
5123
5123
4505
4505
5123
5123
6005
115%
1780
1424
1424
1425
1780
1424
1424
1425
1425
433
585
380
664
664
620
1811
1811
1180
380
1487
1487
1906
1906
620
870
1811
1811
1811
1180
1180
1487
1487
2418
2418
1906
1906
1906
1906
870
990
1811
2652
2652
1180
2075
2418
2418
1906
1906
2957
2957
3149
3149
3530
990
2652
2652
2075
2957
2957
3149
3149
4093
4093
3149
3149
3530
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) 16d sinkers may be used at 0.84 of the table load where 16d commons are specified.
4) NAILS:!" "!"!"
"!"
"! ""! "
red font.
92
S-P-F (kN)
1-800-328-5934 www.USPconnectors.com
100%
12.97
14.35
14.35
18.68
12.97
14.35
14.35
18.68
18.68
4.99
6.03
4.85
6.73
6.73
6.14
6.32
6.32
9.90
4.85
6.73
6.73
10.83
10.83
6.14
6.72
6.32
6.32
10.23
9.90
9.90
6.73
6.73
11.98
11.98
10.83
10.83
14.76
14.76
6.72
7.30
10.23
16.33
16.33
9.90
18.10
11.98
11.98
14.76
14.76
16.37
16.37
22.79
22.79
26.71
7.30
16.33
16.33
18.10
16.37
16.37
22.79
22.79
20.04
20.04
22.79
22.79
26.71
115%
7.92
6.33
6.33
6.34
7.92
6.33
6.33
6.34
6.34
1.93
2.60
1.69
2.95
2.95
2.76
8.06
8.06
5.25
1.69
6.61
6.61
8.48
8.48
2.76
3.87
8.06
8.06
8.06
5.25
5.25
6.61
6.61
10.76
10.76
8.48
8.48
8.48
8.48
3.87
4.40
8.06
11.80
11.80
5.25
9.23
10.76
10.76
8.48
8.48
13.15
13.15
14.01
14.01
15.70
4.40
11.80
11.80
9.23
13.15
13.15
14.01
14.01
18.21
18.21
14.01
14.01
15.70
(2) 2 x 4
USP
Stock No.
SUH214
HD212
HD212IF
HD214
SUH214
HD212
HD212IF
HD214
HD216
JUS24-2
SUH24-2
HD24-2
HUS24-2
HUS24-2IF
DT26
JUS26-2
JUS26-2GC
SUH26-2
HD24-2
HUS26-2
HUS26-2IF
HD26-2
HD26-2IF
DT26
DT28
JUS26-2
JUS26-2GC
JUS28-2
SUH26-2
SUH28-2
HUS26-2
HUS26-2IF
HUS28-2
HUS28-2IF
HD26-2
HD26-2IF
HD28-2
HD28-2IF
DT28
DT210
JUS28-2
JUS210-2
JUS210-2GC
SUH28-2
SUH210-2
HUS28-2
HUS28-2IF
HD28-2
HD28-2IF
HUS210-2
HUS210-2IF
HD210-2
HD210-2IF
HDQ210-2IF
DT210
JUS210-2
JUS210-2GC
SUH210-2
HUS210-2
HUS210-2IF
HD210-2
HD210-2IF
HUS212-2
HUS212-2IF
HD212-2
HD212-2IF
HDQ210-2IF
Joist
continued
Fastener Schedule2,3,4,5
Header
Joist
Dimensions (in)
Joist Size
(2) 2 x 14
(2) 2 x 16
3x4
3x6
3x8
3 x 10
3 x 12
3 x 14
Ref. No.
LUS210-2
-- -LUS214-2
U210-2
HUS210-2
HUSC210-2
HU210-2
HUC210-2
HUS212-2
HUSC212-2
HU212-2
HUC212-2
HU214-2
HUCQ210-2-SDS
LUS214-2
HU212-2
HUC212-2
HU214-2
HU216-2
U34
HU34
HUC34
LUS36
U34
U36
HU36
HUC36
LUS36
-- -U36
HU36
HUC36
HU38
HUC38
-- -LUS310
U310
HU38
HUC38
HU310
HUC310
HUCQ310-SDS
LUS310
U310
HU38
HUC38
HU310
HUC310
HUCQ310-SDS
HU312
U314
HU310
HUC310
HUCQ310-SDS
HU312
HUC312
HU314
HUC314
U314
HU312
HUC312
HU314
HUC314
HU316
HUC316
Steel
Gauge
18
18
18
16
14
14
14
14
14
14
14
14
14
14
18
14
14
14
14
16
14
14
18
16
16
14
14
18
18
16
14
14
14
14
18
18
16
14
14
14
14
14
18
16
14
14
14
14
14
14
16
14
14
14
14
14
14
14
16
14
14
14
14
14
14
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
H
9-1/8
9-1/8
13-1/8
8-9/16
9-1/8
9-1/8
9
9
11-1/8
11-1/8
11
11
13
9
13-1/8
11
11
13
15
3-3/8
3
3
5-5/16
3-3/8
5-5/16
4-3/4
4-3/4
5-5/16
6-3/4
5-5/16
4-3/4
4-3/4
6-3/4
6-3/4
6-3/4
9-1/8
8-7/8
6-3/4
6-3/4
7-7/16
7-7/16
9
9-1/8
8-7/8
6-3/4
6-3/4
7-7/16
7-7/16
9
9-5/16
10-9/16
7-7/16
7-7/16
9
9-5/16
9-5/16
11-5/16
11-5/16
10-9/16
9-5/16
9-5/16
11-5/16
11-5/16
13-5/16
13-5/16
D
2
2
2
2
2
2
2-1/2
2-1/2
2
2
2-1/2
2-1/2
2-1/2
3
2
2-1/2
2-1/2
2-1/2
2-1/2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2-1/2
2-1/2
3
2
2
2
2
2-1/2
2-1/2
3
2-1/2
2
2-1/2
2-1/2
3
2-1/2
2-1/2
2-1/2
2-1/2
2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
A
1
1
1
1-1/8
1
-- -1-1/8
-- -1
-- -1-1/8
-- -1-1/8
1-1/2
1
1-1/8
-- -1-1/8
1-1/8
1-1/8
1-1/8
-- -1
1-1/8
1-1/8
1-1/8
-- -1
1
1-1/8
1-1/8
-- -1-1/8
-- -1
1
1-1/8
1-1/8
-- -1-1/8
-- -1-3/16
1
1-1/8
1-1/8
-- -1-1/8
-- -1-3/16
1-1/8
1-1/8
1-1/8
-- -1-3/16
1-1/8
-- -1-1/8
-- -1-1/8
1-1/8
-- -1-1/8
-- -1-1/8
-- --
Type
16d
N16C-GC
16d
10d
16d
16d
10d
10d
16d
16d
10d
10d
10d
WS3
16d
10d
10d
10d
10d
10d x 1 1/2
10d x 1 1/2
10d x 1 1/2
16d
10d x 1 1/2
10d x 1 1/2
10d x 1 1/2
10d x 1 1/2
16d
16d
10d x 1 1/2
10d x 1 1/2
10d x 1 1/2
10d x 1 1/2
10d x 1 1/2
16d
16d
10d x 1 1/2
10d x 1 1/2
10d x 1 1/2
10d x 1 1/2
10d x 1 1/2
WS15
16d
10d x 1 1/2
10d x 1 1/2
10d x 1 1/2
10d x 1 1/2
10d x 1 1/2
WS15
10d x 1 1/2
10d x 1-1/2
10d x 1 1/2
10d x 1 1/2
WS15
10d x 1 1/2
10d x 1 1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1 1/2
10d x 1 1/2
10d x 1-1/2
10d x 1-1/2
10d x 1 1/2
10d x 1 1/2
100%
5170
5170
5120
5730
5185
5185
7215
7215
6345
6345
7215
7215
7215
8460
5120
7215
7215
7215
7215
1390
1975
1975
2000
1390
2345
2720
2720
2000
3240
2345
2720
2720
3820
3820
3240
5170
4080
3820
3820
7215
7215
5315
5170
4080
3820
3820
7215
7215
5315
7215
4105
7215
7215
5315
7215
7215
7215
7215
4105
7215
7215
7215
7215
7215
7215
115%
3735
3735
3735
2920
4165
4165
4435
4435
5765
5765
4435
4435
4435
4970
3735
4435
4435
4435
4435
795
545
545
2550
795
1505
1555
1555
2550
2550
1505
1555
1555
1555
1555
2550
3735
2505
1555
1555
2005
2005
3025
3735
2505
1555
1555
2005
2005
3025
2005
2505
2005
2005
3025
2005
2005
2005
2005
2505
2005
2005
2005
2005
2005
2005
100%
23.00
23.00
22.78
25.49
23.06
23.06
32.10
32.10
28.23
28.23
32.10
32.10
32.10
37.63
22.78
32.10
32.10
32.10
32.10
6.18
8.79
8.79
8.90
6.18
10.43
12.10
12.10
8.90
14.41
10.43
12.10
12.10
16.99
16.99
14.41
23.00
18.15
16.99
16.99
32.10
32.10
23.64
23.00
18.15
16.99
16.99
32.10
32.10
23.64
32.10
18.26
32.10
32.10
23.64
32.10
32.10
32.10
32.10
18.26
32.10
32.10
32.10
32.10
32.10
32.10
115%
16.61
16.61
16.61
12.99
18.53
18.53
19.73
19.73
25.65
25.65
19.73
19.73
19.73
22.11
16.61
19.73
19.73
19.73
19.73
3.54
2.42
2.42
11.34
3.54
6.69
6.92
6.92
11.34
11.34
6.69
6.92
6.92
6.92
6.92
11.34
16.61
11.14
6.92
6.92
8.92
8.92
13.46
16.61
11.14
6.92
6.92
8.92
8.92
13.46
8.92
11.14
8.92
8.92
13.46
8.92
8.92
8.92
8.92
11.14
8.92
8.92
8.92
8.92
8.92
8.92
100%
3671
3671
3635
4070
3681
3681
5123
5123
4505
4505
5123
5123
5125
6005
3635
5123
5123
5125
5125
985
1402
1402
1420
985
1665
1931
1931
1420
2300
1665
1931
1931
2712
2712
2300
3671
2895
2712
2712
5123
5123
3775
3671
2895
2712
2712
5123
5123
3775
5123
2915
5123
5123
3775
5123
5123
5125
5125
2915
5123
5123
5125
5125
5123
5123
115%
2652
2652
2650
2075
2957
2957
3149
3149
4093
4093
3149
3149
3150
3530
2650
3149
3149
3150
3150
565
387
387
1810
565
1070
1104
1104
1810
1810
1070
1104
1104
1104
1104
1810
2652
1780
1104
1104
1424
1424
2150
2652
1780
1104
1104
1424
1424
2150
1424
1780
1424
1424
2150
1424
1424
1425
1425
1780
1424
1424
1425
1425
1424
1424
100%
16.33
16.33
16.17
18.10
16.37
16.37
22.79
22.79
20.04
20.04
22.79
22.79
22.80
26.71
16.17
22.79
22.79
22.80
22.80
4.38
6.24
6.24
6.32
4.38
7.41
8.59
8.59
6.32
10.23
7.41
8.59
8.59
12.06
12.06
10.23
16.33
12.88
12.06
12.06
22.79
22.79
16.79
16.33
12.88
12.06
12.06
22.79
22.79
16.79
22.79
12.97
22.79
22.79
16.79
22.79
22.79
22.80
22.80
12.97
22.79
22.79
22.80
22.80
22.79
22.79
115%
11.80
11.80
11.79
9.23
13.15
13.15
14.01
14.01
18.21
18.21
14.01
14.01
14.01
15.70
11.79
14.01
14.01
14.01
14.01
2.51
1.72
1.72
8.05
2.51
4.76
4.91
4.91
8.05
8.05
4.76
4.91
4.91
4.91
4.91
8.05
11.80
7.92
4.91
4.91
6.33
6.33
9.56
11.80
7.92
4.91
4.91
6.33
6.33
9.56
6.33
7.92
6.33
6.33
9.56
6.33
6.33
6.34
6.34
7.92
6.33
6.33
6.34
6.34
6.33
6.33
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) 16d sinkers may be used at 0.84 of the table load where 16d commons are specified.
!!#'$#)(
)! # &'% #$
5) NAILS:
( ) $#
)( )! ( ) $#
)( )! $#
)(
)! $# )(
)!
'"#!&%$!#&"%"#!&% !#%! #$ % red font.
1-800-328-5934 www.USPconnectors.com
USP2240-131
Hangers
3 x 16
USP
Stock No.
JUS210-2
JUS210-2GC
JUS214-2
SUH210-2
HUS210-2
HUS210-2IF
HD210-2
HD210-2IF
HUS212-2
HUS212-2IF
HD212-2
HD212-2IF
HD214-2
HDQ210-2IF
JUS214-2
HD212-2
HD212-2IF
HD214-2
HD216-2
SUH34
HD34
HD34IF
JUS36
SUH34
SUH36
HD36
HD36IF
JUS36
JUS38
SUH36
HD36
HD36IF
HD38
HD38IF
JUS38
JUS310
SUH310
HD38
HD38IF
HD310
HD310IF
HDQ310IF
JUS310
SUH310
HD38
HD38IF
HD310
HD310IF
HDQ310IF
HD312
SUH314
HD310
HD310IF
HDQ310IF
HD312
HD312IF
HD314
HD314IF
SUH314
HD312
HD312IF
HD314
HD314IF
HD316
HD316IF
Factored Resistance
DF-L (Lbs)
93
Fastener Schedule2,3,4,5
Header
Joist
Dimensions (in)
Joist Size
(2) 3 x 8
(2) 3 x 10
(2) 3 x 12
(2) 3 x 14
(3) 2 x 6
(3) 2 x 10
(3) 2 x 12
(3) 2 x 14
(3) 2 x 16
(4) 2 x 8
(4) 2 x 10
(4) 2 x 12
(4) 2 x 14
4x4
Hangers
4x6
Ref. No.
HU38-2
HU38-2
HU310-2
HU312-2
HU312-2
LUS26-3
U26-3
HU26-3
HUC26-3
LUS26-3
LUS28-3
U26-3
HU26-3
HUC26-3
-- --- -LUS28-3
LUS210-3
U210-3
-- --- -HU210-3
HUC210-3
HUCQ210-3-SDS
LUS210-3
U210-3
HU210-3
HUC210-3
HUCQ210-3-SDS
HU212-3
HUC212-3
LUS210-3
U210-3
HU210-3
HUC210-3
HUCQ210-3-SDS
HU212-3
HUC212-3
HU214-3
HU212-3
HUC212-3
HU214-3
HU216-3
HU28-4
HU210-4
HU210-4
HU210-4
LUS44
U44
HU44
HUC44
LUS46
U44
U46
HUS46
HUSC46
HU46
HUC46
Steel
Gauge
14
14
14
14
14
18
16
14
14
18
18
16
14
14
14
14
18
18
16
14
14
14
14
14
18
16
14
14
14
14
14
18
16
14
14
14
14
14
14
14
14
14
14
14
14
14
14
18
16
14
14
18
16
16
14
14
14
14
Factored Resistance
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
A
1-1/8
1-1/8
1-1/8
1-1/8
1-1/8
1
1
1-1/8
-- -1
1
1
1-1/8
-- -1-1/8
-- -1
1
1
1-1/8
-- -1-1/8
-- -1-1/2
1
1
1-1/8
-- -1-1/2
1-1/8
-- -1
1
1-1/8
-- -1-1/2
1-1/8
-- -1-1/8
1-1/8
-- -1-1/8
1-1/8
1-3/4
2
2
2
1
1-1/8
1-1/8
-- -1
1-1/8
1-1/8
1
-- -1-1/8
-- --
Qty
14
14
18
22
4
8
12
12
4
6
8
12
12
12
12
6
8
14
12
12
18
18
12
8
14
18
18
12
22
22
8
14
18
18
12
22
22
24
22
22
24
26
14
24
24
24
4
6
4
4
4
6
8
4
4
12
12
Type
16d
16d
16d
16d
16d
16d
10d
16d
16d
16d
16d
10d
16d
16d
16d
16d
16d
16d
10d
16d
16d
16d
16d
WS3
16d
10d
16d
16d
WS3
16d
16d
16d
10d
16d
16d
WS3
16d
16d
16d
16d
16d
16d
16d
16d
16d
16d
16d
16d
10d
16d
16d
16d
10d
10d
16d
16d
16d
16d
Qty
6
6
10
10
10
4
2
6
6
4
4
2
6
6
6
6
4
6
6
6
6
10
10
6
6
6
10
10
6
10
10
6
6
10
10
6
10
10
10
10
10
10
12
6
6
6
6
2
2
2
2
4
2
4
4
4
6
6
Type
10d
10d
10d
10d
10d
16d
10d
10d
10d
16d
16d
10d
10d
10d
10d
10d
16d
16d
10d
10d
10d
10d
10d
WS3
16d
10d
10d
10d
WS3
10d
10d
16d
10d
10d
10d
WS3
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
16d
10d
10d
10d
16d
10d
10d
16d
16d
10d
10d
100%
4675
4675
7215
7215
7215
2000
3135
3430
3430
2000
3240
3135
3430
3430
4675
4675
3240
5170
5730
4675
4675
7215
7215
8460
5170
5730
7215
7215
8460
7215
7215
5170
5730
7215
7215
8460
7215
7215
7215
7215
7215
7215
7215
4675
7215
7215
7215
1580
1910
1535
1535
2000
1910
3135
2130
2130
3430
3430
115%
2685
2685
4435
4435
4435
2550
1665
2685
2685
2550
2550
1665
2685
2685
2685
2685
2550
3735
2920
2685
2685
4435
4435
4970
3735
2920
4435
4435
4970
4435
4435
3735
2920
4435
4435
4970
4435
4435
4435
4435
4435
4435
4435
2685
4435
4435
4435
610
825
535
535
2550
825
1665
2095
2095
2685
2685
100%
20.80
20.80
32.10
32.10
32.10
8.90
13.95
15.26
15.26
8.90
14.41
13.95
15.26
15.26
20.80
20.80
14.41
23.00
25.49
20.80
20.80
32.10
32.10
37.63
23.00
25.49
32.10
32.10
37.63
32.10
32.10
23.00
25.49
32.10
32.10
37.63
32.10
32.10
32.10
32.10
32.10
32.10
32.10
20.80
32.10
32.10
32.10
7.03
8.50
6.83
6.83
8.90
8.50
13.95
9.48
9.48
15.26
15.26
115%
11.94
11.94
19.73
19.73
19.73
11.34
7.41
11.94
11.94
11.34
11.34
7.41
11.94
11.94
11.94
11.94
11.34
16.61
12.99
11.94
11.94
19.73
19.73
22.11
16.61
12.99
19.73
19.73
22.11
19.73
19.73
16.61
12.99
19.73
19.73
22.11
19.73
19.73
19.73
19.73
19.73
19.73
19.73
11.94
19.73
19.73
19.73
2.71
3.67
2.38
2.38
11.34
3.67
7.41
9.32
9.32
11.94
11.94
100%
3320
3320
5123
5125
5125
1420
2225
2435
2435
1420
2300
2225
2435
2435
3319
3319
2300
3671
4070
3319
3319
5123
5123
6005
3671
4070
5123
5123
6005
5123
5123
3671
4070
5123
5123
6005
5123
5123
5125
5123
5123
5125
5125
3320
5125
5125
5125
1122
1355
1090
1090
1420
1355
2225
1512
1512
2435
2435
115%
1905
1905
3149
3150
3150
1811
1180
1906
1906
1811
1811
1180
1906
1906
1906
1906
1811
2652
2075
1906
1906
3149
3149
3530
2652
2075
3149
3149
3530
3149
3149
2652
2075
3149
3149
3530
3149
3149
3150
3149
3149
3150
3150
1905
3150
3150
3150
433
585
380
380
1811
585
1180
1487
1487
1906
1906
100%
14.77
14.77
22.79
22.80
22.80
6.32
9.90
10.83
10.83
6.32
10.23
9.90
10.83
10.83
14.76
14.76
10.23
16.33
18.10
14.76
14.76
22.79
22.79
26.71
16.33
18.10
22.79
22.79
26.71
22.79
22.79
16.33
18.10
22.79
22.79
26.71
22.79
22.79
22.80
22.79
22.79
22.80
22.80
14.77
22.80
22.80
22.80
4.99
6.03
4.85
4.85
6.32
6.03
9.90
6.73
6.73
10.83
10.83
115%
8.47
8.47
14.01
14.01
14.01
8.06
5.25
8.48
8.48
8.06
8.06
5.25
8.48
8.48
8.48
8.48
8.06
11.80
9.23
8.48
8.48
14.01
14.01
15.70
11.80
9.23
14.01
14.01
15.70
14.01
14.01
11.80
9.23
14.01
14.01
15.70
14.01
14.01
14.01
14.01
14.01
14.01
14.01
8.47
14.01
14.01
14.01
1.93
2.60
1.69
1.69
8.06
2.60
5.25
6.61
6.61
8.48
8.48
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) 16d sinkers may be used at 0.84 of the table load where 16d commons are specified.
$! &%
& #$" !
5) NAILS:
% &!
&% &% &!
&% &!
&%
&! &%
&
red font.
94
1-800-328-5934 www.USPconnectors.com
(3) 2 x 8
USP
Stock No.
HD38-2
HD38-2
HD310-2
HD312-2
HD312-2
JUS26-3
SUH26-3
HD26-3
HD26-3IF
JUS26-3
JUS28-3
SUH26-3
HD26-3
HD26-3IF
HD28-3
HD28-3IF
JUS28-3
JUS210-3
SUH210-3
HD28-3
HD28-3IF
HD210-3
HD210-3IF
HDQ210-3IF
JUS210-3
SUH210-3
HD210-3
HD210-3IF
HDQ210-3IF
HD212-3
HD212-3IF
JUS210-3
SUH210-3
HD210-3
HD210-3IF
HDQ210-3IF
HD212-3
HD212-3IF
HD214-3
HD212-3
HD212-3IF
HD214-3
HD216-3
HD28-4
HD210-4
HD210-4
HD210-4
JUS44
SUH44
HD44
HD44IF
JUS46
SUH44
SUH46
HUS46
HUS46IF
HD46
HD46IF
continued
Fastener Schedule2,3,4,5
Header
Joist
Dimensions (in)
Joist Size
%
%
%
%
%
%
%
Ref. No.
LUS46
LUS48, LUS48Z
U46
HUS46
HUSC46
HUS48
HUSC48
HU46
HUC46
HU48
HUC48
LUS48, LUS48Z
LUS410, LUS410Z
U410
HUS48
HUSC48
HU48
HUC48
HUS410
HUSC410
HU410
HUC410
HUCQ410-SDS
LUS410, LUS410Z
U410
HU48
HUC48
HUS410
HUSC410
HU410
HUC410
HUCQ410-SDS
HUS412
HUSC412
HU412
HUC412
HUCQ412-SDS
LUS414
U414
HU410
HUC410
HUCQ410-SDS
HUS412
HUSC412
HU412
HUC412
HUCQ412-SDS
HU414
HUC414
LUS414
U414
HU412
HUC412
HUCQ412-SDS
HU414
HUC414
HU416
HUC416
HU414
HUC414
HU416
HUC416
-- -U66
HU66
HUC66
U66
HU66
HUC66
HU68
HUC68
Steel
Gauge
18
18
16
14
14
14
14
14
14
14
14
18
18
16
14
14
14
14
14
14
14
14
14
18
16
14
14
14
14
14
14
14
14
14
14
14
14
18
16
14
14
14
14
14
14
14
14
14
14
18
16
14
14
14
14
14
14
14
14
14
14
14
14
16
14
14
16
14
14
14
14
Factored Resistance
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
H
5
6-7/8
4-13/16
5
5
7
7
4-15/16
4-15/16
6-7/8
6-7/8
6-7/8
8-7/8
8-3/8
7
7
6-7/8
6-7/8
8-7/8
8-7/8
8-13/16
8-13/16
9
8-7/8
8-3/8
6-7/8
6-7/8
8-7/8
8-7/8
8-13/16
8-13/16
9
10-7/8
10-7/8
10-13/16
10-13/16
11
12-7/8
10-1/16
8-13/16
8-13/16
9
10-7/8
10-7/8
10-13/16
10-13/16
11
12-13/16
12-13/16
12-7/8
10-1/16
10-13/16
10-13/16
11
12-13/16
12-13/16
14-13/16
14-13/16
12-13/16
12-13/16
14-13/16
14-13/16
16-1/2
5
3-15/16
3-15/16
5
3-15/16
3-15/16
5-15/16
5-15/16
D
2
2
2
2
2
2
2
2-1/2
2-1/2
2-1/2
2-1/2
2
2
2
2
2
2-1/2
2-1/2
2
2
2-1/2
2-1/2
3
2
2
2-1/2
2-1/2
2
2
2-1/2
2-1/2
3
2
2
2-1/2
2-1/2
3
2
2
2-1/2
2-1/2
3
2
2
2-1/2
2-1/2
3
2-1/2
2-1/2
2
2
2-1/2
2-1/2
3
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2
2-1/2
2-1/2
2
2-1/2
2-1/2
2-1/2
2-1/2
A
1
1
1-1/8
1
-- -1
1
1-1/8
-- -1-1/8
-- -1
1
1-1/8
1
1
1-1/8
-- -1
-- -1-1/8
-- -1-1/2
1
1-1/8
1-1/8
-- -1
-- -1-1/8
-- -1-1/2
1
-- -1-1/8
-- -1-1/2
1
1-1/8
1-1/8
-- -1-1/2
1
-- -1-1/8
-- -1-1/2
1-1/8
-- -1
1-1/8
1-1/8
-- -1-1/2
1-1/8
-- -1-1/8
-- -1-1/8
-- -1-1/8
-- -1-1/4
1
1-1/8
-- -1
1-1/8
-- -1-1/8
-- --
Qty
4
6
8
4
4
6
6
12
12
14
14
6
8
14
6
6
14
14
8
8
18
18
12
8
14
14
14
8
8
18
18
12
10
10
22
22
14
12
16
18
18
12
10
10
22
22
14
24
24
12
16
22
22
14
24
24
26
26
24
24
26
26
28
8
12
12
8
12
12
14
14
Type
16d
16d
10d
16d
16d
16d
16d
16d
16d
16d
16d
16d
16d
10d
16d
16d
16d
16d
16d
16d
16d
16d
WS3
16d
10d
16d
16d
16d
16d
16d
16d
WS3
16d
16d
16d
16d
WS3
16d
10d
16d
16d
WS3
16d
16d
16d
16d
WS3
16d
16d
16d
10d
16d
16d
WS3
16d
16d
16d
16d
16d
16d
16d
16d
16d
10d
16d
16d
10d
16d
16d
16d
16d
Qty
4
4
4
4
4
6
6
6
6
6
6
4
6
6
6
6
6
6
8
8
10
10
6
6
6
6
6
8
8
10
10
6
10
10
10
10
6
6
6
10
10
6
10
10
10
10
6
10
10
6
6
10
10
6
10
10
12
12
10
10
12
12
8
4
6
6
4
6
6
6
6
Type
16d
16d
10d
16d
16d
16d
16d
10d
10d
10d
10d
16d
16d
10d
16d
16d
10d
10d
16d
16d
10d
10d
WS3
16d
10d
10d
10d
16d
16d
10d
10d
WS3
16d
16d
10d
10d
WS3
16d
10d
10d
10d
WS3
16d
16d
10d
10d
WS3
10d
10d
16d
10d
10d
10d
WS3
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
100%
2000
3240
3135
2130
2130
3795
3795
3430
3430
4675
4675
3240
5170
5730
3795
3795
4675
4675
5185
5185
7215
7215
8460
5170
5730
4675
4675
5185
5185
7215
7215
8460
6345
6345
7215
7215
8460
5120
5730
7215
7215
8460
6345
6345
7215
7215
8460
7215
7215
5120
5730
7215
7215
8460
7215
7215
7215
7215
7215
7215
7215
7215
7215
3135
3430
3430
3135
3430
3430
4675
4675
115%
2550
2550
1665
2095
2095
3405
3405
2685
2685
2685
2685
2550
3735
2920
3405
3405
2685
2685
4165
4165
4435
4435
4970
3735
2920
2685
2685
4165
4165
4435
4435
4970
5765
5765
4435
4435
4970
3735
2920
4435
4435
4970
5765
5765
4435
4435
4970
4435
4435
3735
2920
4435
4435
4970
4435
4435
4435
4435
4435
4435
4435
4435
2685
1665
2685
2685
1665
2685
2685
2685
2685
100%
8.90
14.41
13.95
9.48
9.48
16.88
16.88
15.26
15.26
20.80
20.80
14.41
23.00
25.49
16.88
16.88
20.80
20.80
23.06
23.06
32.10
32.10
37.63
23.00
25.49
20.80
20.80
23.06
23.06
32.10
32.10
37.63
28.23
28.23
32.10
32.10
37.63
22.78
25.49
32.10
32.10
37.63
28.23
28.23
32.10
32.10
37.63
32.10
32.10
22.78
25.49
32.10
32.10
37.63
32.10
32.10
32.10
32.10
32.10
32.10
32.10
32.10
32.10
13.95
15.26
15.26
13.95
15.26
15.26
20.80
20.80
115%
11.34
11.34
7.41
9.32
9.32
15.15
15.15
11.94
11.94
11.94
11.94
11.34
16.61
12.99
15.15
15.15
11.94
11.94
18.53
18.53
19.73
19.73
22.11
16.61
12.99
11.94
11.94
18.53
18.53
19.73
19.73
22.11
25.65
25.65
19.73
19.73
22.11
16.61
12.99
19.73
19.73
22.11
25.65
25.65
19.73
19.73
22.11
19.73
19.73
16.61
12.99
19.73
19.73
22.11
19.73
19.73
19.73
19.73
19.73
19.73
19.73
19.73
11.94
7.41
11.94
11.94
7.41
11.94
11.94
11.94
11.94
100%
1420
2300
2225
1512
1512
2694
2694
2435
2435
3319
3319
2300
3671
4070
2694
2694
3319
3319
3681
3681
5123
5123
6005
3671
4070
3319
3319
3681
3681
5123
5123
6005
4505
4505
5123
5123
6005
3635
4070
5123
5123
6005
4505
4505
5123
5123
6005
5123
5123
3635
4070
5123
5123
6005
5123
5123
5123
5123
5123
5123
5123
5123
5123
2225
2435
2435
2225
2435
2435
3319
3319
115%
1811
1811
1180
1487
1487
2418
2418
1906
1906
1906
1906
1811
2652
2075
2418
2418
1906
1906
2957
2957
3149
3149
3530
2652
2075
1906
1906
2957
2957
3149
3149
3530
4093
4093
3149
3149
3530
2650
2075
3149
3149
3530
4093
4093
3149
3149
3530
3149
3149
2650
2075
3149
3149
3530
3149
3149
3149
3149
3149
3149
3149
3149
1906
1180
1906
1906
1180
1906
1906
1906
1906
100%
6.32
10.23
9.90
6.73
6.73
11.98
11.98
10.83
10.83
14.76
14.76
10.23
16.33
18.10
11.98
11.98
14.76
14.76
16.37
16.37
22.79
22.79
26.71
16.33
18.10
14.76
14.76
16.37
16.37
22.79
22.79
26.71
20.04
20.04
22.79
22.79
26.71
16.17
18.10
22.79
22.79
26.71
20.04
20.04
22.79
22.79
26.71
22.79
22.79
16.17
18.10
22.79
22.79
26.71
22.79
22.79
22.79
22.79
22.79
22.79
22.79
22.79
22.79
9.90
10.83
10.83
9.90
10.83
10.83
14.76
14.76
115%
8.06
8.06
5.25
6.61
6.61
10.76
10.76
8.48
8.48
8.48
8.48
8.06
11.80
9.23
10.76
10.76
8.48
8.48
13.15
13.15
14.01
14.01
15.70
11.80
9.23
8.48
8.48
13.15
13.15
14.01
14.01
15.70
18.21
18.21
14.01
14.01
15.70
11.79
9.23
14.01
14.01
15.70
18.21
18.21
14.01
14.01
15.70
14.01
14.01
11.79
9.23
14.01
14.01
15.70
14.01
14.01
14.01
14.01
14.01
14.01
14.01
14.01
8.48
5.25
8.48
8.48
5.25
8.48
8.48
8.48
8.48
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) 16d sinkers may be used at 0.84 of the table load where 16d commons are specified.
$! &%
& #$" !
5) NAILS:
% &!
&% &% &!
&% &!
&%
&! &%
&
red font.
1-800-328-5934 www.USPconnectors.com
USP2240-131
Hangers
%
USP
Stock No.
JUS46
JUS48
SUH46
HUS46
HUS46IF
HUS48
HUS48IF
HD46
HD46IF
HD48
HD48IF
JUS48
JUS410
SUH410
HUS48
HUS48IF
HD48
HD48IF
HUS410
HUS410IF
HD410
HD410IF
HDQ410IF
JUS410
SUH410
HD48
HD48IF
HUS410
HUS410IF
HD410
HD410IF
HDQ410IF
HUS412
HUS412IF
HD412
HD412IF
HDQ412IF
JUS414
SUH414
HD410
HD410IF
HDQ410IF
HUS412
HUS412IF
HD412
HD412IF
HDQ412IF
HD414
HD414IF
JUS414
SUH414
HD412
HD412IF
HDQ412IF
HD414
HD414IF
HD416
HD416IF
HD414
HD414IF
HD416
HD416IF
HD418
SUH66
HD66
HD66IF
SUH66
HD66
HD66IF
HD68
HD68IF
continued
95
Joist Size
6 x 10
6 x 14
6 x 16
6 x 18
8x6
8x8
8 x 10
8 x 12
8 x 14
8 x 16
Hangers
2x4
2x6-8
2 x 8 - 10
2 x 10 - 14
2 x 14 - 16
4x6
4x8
4 x 10
6x8
6 x 10
Ref. No.
U610
HU68
HUC68
HU610
HUC610
HUCQ610-SDS
U610
HU610
HUC610
HUCQ610-SDS
HU612
HUC612
HUCQ612-SDS
HU610
HUC610
HUCQ610-SDS
HU612
HUC612
HUCQ612-SDS
HU614
HUC614
HU612
HUC612
HUCQ612-SDS
HU614
HUC614
HU616
HUC616
HU614
HUC614
HU616
HUC616
-- --- -HU88
HUC88
HU810
HUC810
HU812
HUC812
HU814
HUC814
HU816
HUC816
SUH24R
SUH26R
SUH28R
SUH210R
SUH214R
SUH44R
SUH46R
SUH410R
SUH66R
SUH610R
LU24R-18, U24R
LU26R-18, U26R
LU28R-18
LU210R-18, U210R
-- -U44R
U46R
U410R
U66R
U610R
Steel
Gauge
16
14
14
14
14
14
16
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
Fastener Schedule2,3,4,5
Header
Joist
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
14
14
W
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
5-1/2
7-1/2
7-1/2
7-1/2
7-1/2
7-1/2
7-1/2
7-1/2
7-1/2
7-1/2
7-1/2
7-1/2
7-1/2
H
9
5-15/16
5-15/16
7-13/16
7-13/16
9
9
7-13/16
7-13/16
9
9-13/16
9-13/16
11
7-13/16
7-13/16
9
9-13/16
9-13/16
11
11-13/16
11-13/16
9-13/16
9-13/16
11
11-13/16
11-13/16
13-13/16
13-13/16
11-13/16
11-13/16
13-13/16
13-13/16
5-1/8
5-1/8
6-5/8
6-5/8
8-3/8
8-3/8
10-1/8
10-1/8
11-7/8
11-7/8
13-5/8
13-5/8
D
2
2-1/2
2-1/2
2-1/2
2-1/2
3
2
2-1/2
2-1/2
3
2-1/2
2-1/2
3
2-1/2
2-1/2
3
2-1/2
2-1/2
3
2-1/2
2-1/2
2-1/2
2-1/2
3
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
16
16
16
16
16
16
16
16
16
16
2
2
2
2
2
4
4
4
6
6
3-1/16
4-15/16
6-7/16
7-13/16
9-13/16
2-11/16
4-11/16
8-3/16
5
9
2
2
2
2
2
2
2
2
2
2
2
4
6
6
6
2
4
6
4
6
Type
10d
10d
10d
10d
10d
WS3
10d
10d
10d
WS3
10d
10d
WS3
10d
10d
WS3
10d
10d
WS3
10d
10d
10d
10d
WS3
10d
10d
10d
10d
10d
10d
10d
10d
16d
16d
16d
16d
16d
16d
16d
16d
16d
16d
16d
16d
100%
5730
4675
4675
7215
7215
8460
5730
7215
7215
8460
7215
7215
8460
7215
7215
8460
7215
7215
8460
7215
7215
7215
7215
8460
7215
7215
7215
7215
7215
7215
7215
7215
2525
2525
4900
4900
7315
7315
7315
7315
7315
7315
7315
7315
115%
2920
2685
2685
4435
4435
4970
2920
4435
4435
4970
4435
4435
4970
4435
4435
4970
4435
4435
4970
4435
4435
4435
4435
4970
4435
4435
4435
4435
4435
4435
4435
4435
4435
4435
4435
4435
4435
4435
4435
4435
5260
5260
5260
5260
100%
25.49
20.80
20.80
32.10
32.10
37.63
25.49
32.10
32.10
37.63
32.10
32.10
37.63
32.10
32.10
37.63
32.10
32.10
37.63
32.10
32.10
32.10
32.10
37.63
32.10
32.10
32.10
32.10
32.10
32.10
32.10
32.10
11.23
11.23
21.80
21.80
32.54
32.54
32.54
32.54
32.54
32.54
32.54
32.54
115%
12.99
11.94
11.94
19.73
19.73
22.11
12.99
19.73
19.73
22.11
19.73
19.73
22.11
19.73
19.73
22.11
19.73
19.73
22.11
19.73
19.73
19.73
19.73
22.11
19.73
19.73
19.73
19.73
19.73
19.73
19.73
19.73
19.73
19.73
19.73
19.73
19.73
19.73
19.73
19.73
23.40
23.40
23.40
23.40
100%
4070
3319
3319
5123
5123
6005
4070
5123
5123
6005
5123
5123
6005
5123
5123
6005
5123
5123
6005
5123
5123
5123
5123
6005
5123
5123
5123
5123
5123
5123
5123
5123
1793
1793
3479
3479
5194
5194
5194
5194
5194
5194
5194
5194
115%
2075
1906
1906
3149
3149
3530
2075
3149
3149
3530
3149
3149
3530
3149
3149
3530
3149
3149
3530
3149
3149
3149
3149
3530
3149
3149
3149
3149
3149
3149
3149
3149
3149
3149
3149
3149
3149
3149
3149
3149
3735
3735
3735
3735
100%
18.10
14.76
14.76
22.79
22.79
26.71
18.10
22.79
22.79
26.71
22.79
22.79
26.71
22.79
22.79
26.71
22.79
22.79
26.71
22.79
22.79
22.79
22.79
26.71
22.79
22.79
22.79
22.79
22.79
22.79
22.79
22.79
7.98
7.98
15.48
15.48
23.10
23.10
23.10
23.10
23.10
23.10
23.10
23.10
115%
9.23
8.48
8.48
14.01
14.01
15.70
9.23
14.01
14.01
15.70
14.01
14.01
15.70
14.01
14.01
15.70
14.01
14.01
15.70
14.01
14.01
14.01
14.01
15.70
14.01
14.01
14.01
14.01
14.01
14.01
14.01
14.01
14.01
14.01
14.01
14.01
14.01
14.01
14.01
14.01
16.61
16.61
16.61
16.61
10d x 1 1/2
10d x 1 1/2
10d x 1-1/2
10d x 1 1/2
10d x 1-1/2
16d
16d
16d
16d
16d
1390
2345
2345
4080
4105
1910
3135
5730
3135
5730
795
1505
1505
2505
2505
825
1665
2920
1665
2920
6.18
10.43
10.43
18.15
18.26
8.50
13.95
25.49
13.95
25.49
3.54
6.69
6.69
11.14
11.14
3.67
7.41
12.99
7.41
12.99
985
1665
1665
2895
2915
1355
2225
4070
2225
4070
565
1070
1070
1780
1780
585
1180
2075
1180
2075
4.38
7.41
7.41
12.88
12.97
6.03
9.90
18.10
9.90
18.10
2.51
4.76
4.76
7.92
7.92
2.60
5.25
9.23
5.25
9.23
7215
4435
32.10
19.73
5123
3149
22.79
14.01
7215
4435
32.10
19.73
5123
3149
22.79
14.01
7215
4435
32.10
19.73
5123
3149
22.79
14.01
7215
4435
32.10
19.73
5123
3149
22.79
14.01
3-1/8 x
HD32105
HU3.25/10.5
14
3-1/4 9-15/16 2-1/2 1-1/8 22
16d
10
10d
10-1/2 - 19-1/2
3-1/8 x
HD3212
HU3.25/12
14
3-1/4 11-7/8 2-1/2 1-1/8 24
16d
10
10d
12 - 21
5-1/8 x
HD5112
HU5.125/12
14
5-1/4 9-15/16 2-1/2 1-1/8 22
16d
10
10d
10-1/2 - 19-1/2
5-1/8 x
HD51135
HU5.125/13.5
14
5-1/4 12-15/16 2-1/2 1-1/8 26
16d
12
10d
14-1/2 - 21
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) 16d sinkers may be used at 0.84 of the table load where 16d commons are specified.
!%"!'&
'!$%#!"
5) NAILS:& '"!
'& '"!
'&
'"! '&
'
% !$#"!$ # !$#!#!"# red font.
96
Factored Resistance
DF-L (Lbs)
1-800-328-5934 www.USPconnectors.com
6 x 12
USP
Stock No.
SUH610
HD68
HD68IF
HD610
HD610IF
HDQ610IF
SUH610
HD610
HD610IF
HDQ610IF
HD612
HD612IF
HDQ612IF
HD610
HD610IF
HDQ610IF
HD612
HD612IF
HDQ612IF
HD614
HD614IF
HD612
HD612IF
HDQ612IF
HD614
HD614IF
HD616
HD616IF
HD614
HD614IF
HD616
HD616IF
HD86
HD86IF
HD88
HD88IF
HD810
HD810IF
HD812
HD812IF
HD814
HD814IF
HD816
HD816IF
continued
TF
KLB 14 gauge.
KB 12 gauge.
KB
Installation:
Use all specified fasteners. See Product Notes, page 10.
NA20D and NA25 nails are included with hangers where
applicable.
KB models are not recommended for use with LVL, PSL,
or LSL members.
TF
KLB
1 1/4
Materials: 12 gauge
Finish: G90 galvanizing
Options: All nominal lumber sizes are available for
rough/fullsize lumber. See Specialty Options
Chart.
Codes: Load values are derived from data
submitted to various North American
building code evaluators.
TF
HDO28-2
Installation:
Use all specified fasteners. See Product Notes, page 10.
Check top flange dimensions to ensure compatibility with
header widths.
Do not use for welded or nailer applications.
Reference Specialty Options chart below for hanger
options.
Specialty Options Chart refer to Specialty Options pages 210 to 211 for
additional details.
Skewed1,3
Sloped Seat2,3
Sloped / Skewed1,2,3
Inverted Flange
Range
Not available in
Factored
Resistance
Ordering
Typical HDO410IF
inverted flange installation
Add IF
to product number.
Ex. HDO610IF
1) Skewed hangers with skews greater than 15 may have all joist nailing on outside flange.
2) Sloped or sloped / skewed hangers with slopes greater than 15 may have additional joist nails.
3) All sloped, skewed, or combinations require bevel cut on joist in all applications and web stiffeners with I-joists.
1-800-328-5934 www.USPconnectors.com
USP2240-131
Hangers
Option
97
Fastener Schedule
USP
Stock No.
SW
SWH
KHW
Nailer
Size
2X
2X
3X
3X
Header
Qty
2
2
2
4
Joist
Type
10d x 1-1/2
10d x 1-1/2
16d x 2-1/2
16d x 2-1/2
Qty
2
2
2
2
Type
10d x 1-1/2
10d
10d
10d
DF-L
Lbs
2355
3745
4825
7460
kN
10.48
16.66
21.46
33.19
2 1/2
2 1/2
L
2 1/2
H
H
SWH410
Typical KHW46
installation
Typical SW210
installation
KHW46
SW210
S-P-F
Lbs
1605
2550
3285
5075
kN
7.14
11.34
14.61
22.58
Specialty Options Chart refer to Specialty Options pages 210 and 212 for additional details.
Option
Skewed1
Sloped Seat2
Sloped / Skewed1,2
See Sloped Seat
and Skewed
Range
&"
&
&"
&
Saddle
Ridge
0 to 35
-- --
-- --
%"
%
Factored
Resistance
#"
values using
straight-line interpolation
Ordering
Add DA,
angle required
to product number.
Ex. SW212-DA30
Hanger Width
' !!
'"'
'"
'
% of table value:
60%
75%
1) Skewed hangers with skews greater than 15 may have all joist nailing on outside flange.
2) Sloped or sloped / skewed hangers with slopes greater than 15 may have additional joist nails.
3) Sloped top flanges with greater than 15 may have additional header nails.
TF
Hangers
These top mount hangers are designed for supporting floor joists or 2x purlins.
The top mount style allows builders to drop in joists or purlins quickly.
Materials: 18 gauge
Finish: G90 galvanizing
Codes: Load values are derived from data submitted to
various North American building code evaluators.
Installation:
Use all specified fasteners. See Product Notes, page 10.
98
1-800-328-5934 www.USPconnectors.com
HL210
KHW Heavy-duty hanger installs with NA20D nails for higher load
capacities.
Materials: SW top flange - 12 gauge; stirrup - 12 gauge;
SWH top flange - 7 gauge; stirrup - 12 gauge;
KHW top flange - 3 gauge; stirrup - 10 gauge.
Finish: USP primer
Options: All nominal lumber sizes are available for
rough/full size lumber. See Specialty
Options Chart.
Codes: Load values are derived from data
L
submitted to various North American
building code evaluators.
Installation:
Use all specified fasteners. See Product
Notes, page 10.
NA20D nails are supplied with KHW hangers
For welded installations see page 213.
KHW models are not recommended for
use with LVL, PSL, or LSL members.
Dimensions (in)
Header
Joist
DF-L
Qty
Beam/
Joist Size
2x4
2x6
2x8
2 x 10
2 x 12
2 x 14
2 x 16
3x4
3x6
3x8
3 x 10
3 x 12
3 x 14
3 x 16
(2) 2 x 4
(2) 2 x 6
Ref. No.
HU24TF
HL26
JB26
18
1-9/16
5-3/8
KLB26
LB26
14
1-9/16
5-3/8
SW26
W26
12
1-9/16
HDO26
HU26TF
12
1-9/16
HL28
JB28
KLB28
LB28
SW28
HDO28
TF
2-1/2
1-1/2
-- --
1-5/16
1-1/2
-- --
1-3/8
5-3/8
2-1/2
6-1/2
2-1/2
5-3/8
2-1/4
-- --
2-1/2
18
-- --
14
1-9/16
1-3/4
-- --
W28
12
1-9/16
7-1/8
2-1/2
HU28TF
12
1-9/16
7-1/8
2-1/4
HL210
JB210
18
1-9/16 9-5/16
KLB210
LB210
14
1-9/16
SW210
W210
12
1-9/16
HDO210
HU210TF
12
1-9/16
HL212
JB212
KLB212
LB212
SW212
HDO212
Lbs
kN
Type
16d
Qty
2
Type
10d x 1-1/2
100%
3125
16d
16d
prongs
1830
-- --
10d x 1-1/2
3325
670
-- --
10d
10d x 1-1/2
3335
-- --
14.84
-- --
2265
-- --
10.08
-- --
16d
10d x 1-1/2
3730
795
16.59
3.54
3135
670
13.95
2.98
1-5/16
1-3/8
16d
prongs
2290
-- --
10.19
-- --
1555
-- --
6.92
-- --
16d
10d x 1-1/2
3325
670
14.79
2.98
2905
585
12.92
2.60
6-1/2
2-1/2
-- --
2-1/2
-- --
10d
10d x 1-1/2
3335
-- --
14.84
-- --
2265
-- --
10.08
-- --
16d
10d x 1-1/2
3730
780
16.59
3.47
3135
655
13.95
2.91
-- --
-- --
1-5/16
16d
prongs
2290
-- --
10.19
-- --
1555
-- --
6.92
-- --
1-3/8
16d
10d x 1-1/2
3325
670
14.79
2.98
2905
585
12.92
2.60
9-1/8
2-1/2
9-1/8
2-1/4
6-1/2
2-1/2
-- --
10d
10d x 1-1/2
3335
-- --
14.84
-- --
2265
-- --
10.08
-- --
-- --
2-1/2
16d
10d x 1-1/2
3730
750
16.59
3.34
3135
630
13.95
2.80
18
14
-- --
1-5/16
16d
prongs
2290
-- --
10.19
-- --
1555
-- --
6.92
-- --
1-9/16 11-1/8
-- --
1-3/8
16d
10d x 1-1/2
3325
670
14.79
2.98
2905
585
12.92
2.60
W212
12
HU212TF
12
1-9/16
6-1/2
2-1/2
-- --
10d
10d x 1-1/2
3335
-- --
14.84
-- --
2265
-- --
10.08
-- --
-- --
2-1/2
10
16d
10d x 1-1/2
3390
1190
15.08
5.29
2850
1000
12.68
4.45
1.40
7-1/4
9-1/4
11
2
2-1/4
115%
325
100%
13.90
115%
1.45
100%
2625
115%
275
100%
11.68
115%
1.22
8.14
-- --
1245
-- --
5.54
-- --
14.79
2.98
2905
585
12.92
2.60
HL214
JB214, LB214
18
1-9/16 13-1/8
-- --
2-1/2
16d
10d x 1-1/2
2290
375
10.19
1.67
1925
315
8.56
W214
12
6-1/2
2-1/2
-- --
10d
10d x 1-1/2
3335
-- --
14.84
-- --
2265
-- --
10.08
-- --
HDO214
HU214TF
12
1-9/16
2-1/4
-- --
2-1/2
12
16d
10d x 1-1/2
4075
1085
18.13
4.83
3425
910
15.24
4.05
13
Top Face
4
2
SW214
SW216
W216
12
6-1/2
2-1/2
-- --
10d
10d x 1-1/2
3335
-- --
14.84
-- --
2265
-- --
10.08
-- --
HDO216
HU216TF, LB216
12
1-9/16
-- --
2-1/2
14
16d
10d x 1-1/2
4420
1590
19.66
7.07
3715
1335
16.53
5.94
1.22
15
2-1/4
HDO34
HU34TF
12
-- --
2-1/2
16d
10d x 1-1/2
3840
325
17.08
1.45
3225
275
14.35
SW36
W36
12
2-9/16
5-3/8
2-1/2
6-1/2
2-1/2
-- --
10d
10d x 1-1/2
3335
-- --
14.84
-- --
2265
-- --
10.08
-- --
HDO36
HU36TF
12
2-9/16
5-3/8
2-1/2
-- --
2-1/2
16d
10d x 1-1/2
4335
795
19.28
3.54
3640
670
16.19
2.98
SW38
W38
12
2-9/16
7-1/8
2-1/2
6-1/2
2-1/2
-- --
10d
10d x 1-1/2
3335
-- --
14.84
-- --
2265
-- --
10.08
-- --
HDO38
B38, HU38TF
12
2-9/16
7-1/8
2-1/2
-- --
2-1/2
16d
10d x 1-1/2
5190
780
23.09
3.47
4360
655
19.40
2.91
SW310
W310
12
2-9/16
9-1/8
2-1/2
6-1/2
2-1/2
-- --
10d
10d x 1-1/2
3335
-- --
14.84
-- --
2265
-- --
10.08
-- --
HDO310
B310, HU310TF
12
2-9/16
9-1/8
2-1/2
-- --
2-1/2
10
16d
10d x 1-1/2
6000
1190
26.69
5.29
5040
1000
22.42
4.45
SWH312
WNP312
HDO312
B312, HU312TF
SWH314
WNP314
HDO314
B314, HU314TF
SWH316
WNP316
HDO316
B316, HU316TF
HDO24-2
HU24-2TF
SWH26-2
WNP26-2
HU26-2TF,
HUS26-2TF
WNP28-2
HU28-2TF,
HUS28-2TF
WNP210-2
HU210-2TF,
HUS210-2TF
HUC210-2TF,
HUSC210-2TF
HDO26-2
HDO28-2
SWH210-2
(2) 2 x 10
S-P-F
kN
SWH28-2
(2) 2 x 8
Steel
Gauge
W
H
D
12
1-9/16 3-7/16 2-1/4
USP
Stock No.
HDO24
Lbs
HDO210-2
HDO210-2IF
7/12
12
7/12
12
7/12
12
11
2-1/2
13
2-1/2
15
2-1/2
-- --
10d
10d x 1-1/2
4760
-- --
21.17
-- --
3235
-- --
14.39
-- --
-- --
2-1/2
12
16d
10d x 1-1/2
6445
1190
28.67
5.29
5415
1000
24.09
4.45
2-1/2
-- --
10d
10d x 1-1/2
4760
-- --
21.17
-- --
3235
-- --
14.39
-- --
-- --
2-1/2
14
16d
10d x 1-1/2
6445
1360
28.67
6.05
5415
1140
24.09
5.07
2-1/2
-- --
10d
10d x 1-1/2
4760
-- --
21.17
-- --
3235
-- --
14.39
-- --
2-1/2
-- --
2-1/2
16
16d
10d x 1-1/2
7005
1590
31.16
7.07
5885
1335
26.18
5.94
1.58
12
3-1/8
3-7/16 2-1/4
-- --
2-1/2
16d
10d
3520
420
15.66
1.87
2955
355
13.15
7/12
3-1/8
5-3/8
2-1/2
2-1/2
-- --
10d
10d
4760
-- --
21.17
-- --
3235
-- --
14.39
-- --
12
3-1/8
5-3/8
2-1/4
-- --
2-1/2
16d
10d
4390
845
19.53
3.76
3690
710
16.41
3.16
7/12
3-1/8
7-1/8
2-1/2
2-1/2
-- --
10d
10d
4760
-- --
21.17
-- --
3235
-- --
14.39
-- --
12
3-1/8
7-1/8
2-1/4
-- --
2-1/2
16d
10d
5510
845
24.51
3.76
4630
710
20.60
3.16
7/12
3-1/8
9-1/8
2-1/2
2-1/2
-- --
10d
10d
4760
-- --
21.17
-- --
3235
-- --
14.39
-- --
12
3-1/8
9-1/8
2-1/2
-- --
2-1/2
10
16d
10d
6575
1265
29.25
5.63
5525
1065
24.58
4.74
12
3-1/8
9-1/8
2-1/2
-- --
2-1/2
10
16d
10d
6575
1265
29.25
5.63
5525
1065
24.58
4.74
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) HL, SW, and SWH products do not provide uplift resistance, except for the HL214.
3) Minimum nail embedment shall be 8 nail diameters (typ).
4) NAILS:
New products or updated product information are designated in red font.
2 1/2
Hangers
USP2240-131
99
continued
Fastener Schedule3,5
Dimensions (in)
Header
Joist
DF-L
Qty
Beam/
Joist Size
(2) 2 x 12
(2) 2 x 14
4x4
4x6
HDO212-2
SWH214-2
WNP214-2
HU214-2TF,
HUS214-2TF
3-1/8
7/12
3-1/8
12
3-1/8
WNP216-2
7/12
3-1/8
12
3-1/8
HDO44
HU44TF
12
3-9/16
SW46
W46
HU46TF,
HUS46TF
HW46
12
3-9/16
12
3-9/16
HDO48
W48
B48, BA48,
HU48TF,
HUS48TF
kN
H
D
11-1/8 2-1/2
11
2-1/2
13-1/8 2-1/2
13
2-1/2
15-1/8 2-1/2
L
7
TF
2-1/2
-- --
2-1/2
Top Face
2 -- -4
12
Type
10d
Qty
2
Type
10d
100%
4760
115%
-- --
100%
21.17
115%
-- --
100%
3235
115%
-- --
100%
14.39
115%
-- --
16d
10d
7025
1265
31.25
5.63
5900
1065
26.25
4.74
2-1/2
-- --
10d
10d
4760
-- --
21.17
-- --
3235
-- --
14.39
-- --
-- --
2-1/2
14
16d
10d
7450
1680
33.14
7.47
6260
1410
27.85
6.27
2-1/2
-- --
10d
10d
4760
-- --
21.17
-- --
3235
-- --
14.39
-- --
-- --
2-1/2
16
16d
10d
7885
1680
35.08
7.47
6625
1410
29.47
6.27
3-7/16 2-1/4
-- --
2-1/2
16d
10d
3520
420
15.66
1.87
2955
355
13.15
1.58
5-3/8
2-1/2
6-1/2
2-1/2
-- --
10d
10d
3630
-- --
16.15
-- --
2470
-- --
10.99
-- --
5-3/8
2-1/4
-- --
2-1/2
16d
10d
4390
845
19.53
3.76
3690
710
16.41
3.16
15
2-1/2
3/10
3-9/16
5-3/8
2-1/2
10
2-1/2
-- --
NA20D
10d
7680
-- --
34.16
-- --
5225
-- --
23.24
-- --
12
3-9/16
7-1/8
2-1/2
6-1/2
2-1/2
-- --
10d
10d
3630
-- --
16.15
-- --
2470
-- --
10.99
-- --
12
3-9/16
7-1/8
2-1/4
-- --
2-1/2
16d
10d
5510
845
24.51
3.76
4630
710
20.60
3.16
KHW48
HW48
3/10
3-9/16
7-1/8
2-1/2
10
2-1/2
-- --
NA20D
10d
7680
-- --
34.16
-- --
5225
-- --
23.24
-- --
SW410
W410
12
3-9/16
9-1/8
2-1/2
6-1/2
2-1/2
-- --
10d
10d
3630
-- --
16.15
-- --
2470
-- --
10.99
-- --
HDO410
B410, HU410TF,
HUI49.5TF,
HUS410TF
12
3-9/16
9-1/8
2-1/4
-- --
2-1/2
10
16d
10d
6575
1265
29.25
5.63
5525
1065
24.58
4.74
-- --
7/12
3-9/16
9-1/8
2-1/2
2-1/2
-- --
10d
10d
4760
-- --
21.17
-- --
3235
-- --
14.39
-- --
3/10
3-9/16
9-1/8
2-1/2
10
2-1/2
-- --
NA20D
10d
7680
-- --
34.16
-- --
5225
-- --
23.24
-- --
12
3-9/16
11-1/8 2-3/8
12
3-9/16
KHW410
HW410
KB412
SWH412
B412
HU412TF,
HUS412TF
WNP412
7/12
3-9/16
11-1/8 2-1/2
2-1/2
-- --
10d
10d
4760
-- --
21.17
-- --
3235
-- --
14.39
-- --
KHW412
HW412
3/10
3-9/16
11-1/8 2-1/2
10
2-1/2
-- --
NA20D
10d
7680
-- --
34.16
-- --
5225
-- --
23.24
-- --
HDO414
B414, HHB414,
HU414TF,
HUI414TF,
HUS414TF
12
3-9/16
-- --
2-1/2
14
16d
10d
7450
1680
33.14
7.47
6260
1410
27.85
6.27
HDO412
4 x 14
4 x 16
12
HU216-2TF
SWH410
4 x 12
W
3-1/8
SWH216-2
HDO46
Lbs
Steel
Gauge
7/12
HDO216-2
KHW46
4 x 10
HU212-2TF,
HUS212-2TF
HDO214-2
SW48
4x8
Ref. No.
WNP212-2
S-P-F
kN
11
13
2-1/4
2-1/2
-- --
2-1/2
NA20D
NA20D
4165
810
18.53
3.60
2960
750
13.17
3.34
-- --
2-1/2
12
16d
10d
7025
1265
31.25
5.63
5900
1065
26.25
4.74
SWH414
WNP414
7/12
3-9/16
13-1/8 2-1/2
2-1/2
-- --
10d
10d
4760
-- --
21.17
-- --
3235
-- --
14.39
-- --
KHW414
HW414
3/10
3-9/16
13-1/8 2-1/2
10
2-1/2
-- --
NA20D
10d
7680
-- --
34.16
-- --
5225
-- --
23.24
-- --
HDO416
B416, HHB416,
HU416TF
12
3-9/16
-- --
2-1/2
16
16d
10d
7885
1680
35.08
7.47
6625
1410
29.47
6.27
15
2-1/2
SWH416
WNP416
7/12
3-9/16
15-1/8 2-1/2
2-1/2
-- --
10d
10d
4760
-- --
21.17
-- --
3235
-- --
14.39
-- --
KHW416
HW416
3/10
3-9/16
15-1/8 2-1/2
10
2-1/2
-- --
NA20D
10d
7680
-- --
34.16
-- --
5225
-- --
23.24
-- --
(3) 2 x 10
HDO210-3
HU210-3TF
12
4-11/16
9-1/8
2-1/2
-- --
2-1/2
10
16d
16d
6575
1480
29.25
6.58
5525
1245
24.58
5.54
(3) 2 x 12
HDO212-3
HU212-3TF
12
4-11/16
11
2-1/2
-- --
2-1/2
12
16d
16d
7025
1480
31.25
6.58
5900
1245
26.25
5.54
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) KHW, SW, and SWH products do not provide uplift resistance.
3) Minimum nail embedment shall be 8 nail diameters (typ).
4) KHW Glulam load values are based on 560 psi perpendicular to grain loading.
5) NAILS:
$# $$# $
$#$!"
New products or updated product information are designated in red font.
2 1/2
Hangers
100
1-800-328-5934 www.USPconnectors.com
(2) 2 x 16
USP
Stock No.
SWH212-2
Lbs
continued
3,5
Dimensions (in)
Fastener Schedule
Header
Joist
DF-L
Qty
USP
Stock No.
HDO214-3
Ref. No.
HU214-3TF
Steel
Gauge
12
W
4-11/16
(3) 2 x 16
HDO216-3
HU216-3TF
12
HDO66
HU66TF
12
SWH66
WNP66
KHW66
HW66
HDO68
HHB68, HU68TF
SWH68
WNP68
KHW68
HW68
3/10
KB610
12
5-1/2
9-1/4
2-3/8
-- --
2-1/2
12
5-1/2
9-1/8
2-1/2
-- --
2-1/2
SWH610
B610
HHB610,
HU610TF
WNP610
7/12
5-1/2
9-1/8
2-1/2
2-1/2
KHW610
HW610
3/10
5-1/2
9-1/8
2-1/2
10
2-1/2
KB612
11-1/8 2-3/8
KHW616
B612
HHB612,
HU612TF
HW612
B614, HHB614,
HU614TF
HW614
B616, HHB616,
HU616TF
HW616
KHW86
HW86
6x8
6 x 10
6 x 12
HDO610
HDO612
KHW612
6 x 14
HDO614
KHW614
6 x 16
8x6
HDO616
S-P-F
kN
Lbs
kN
Beam/
Joist Size
(3) 2 x 14
6x6
Lbs
H
13
D
2-1/2
L
-- --
TF
2-1/2
4-11/16
15
2-1/2
-- --
2-1/2
5-1/2
5-3/8
2-1/2
-- --
2-1/2
7/12
5-1/2
5-3/8
2-1/2
2-1/2
3/10
5-1/2
5-3/8
2-1/2
10
12
5-1/2
7-1/8
2-1/2
7/12
5-1/2
7-1/8
2-1/2
5-1/2
7-1/8
2-1/2
12
5-1/2
12
5-1/2
3/10
5-1/2
12
5-1/2
3/10
5-1/2
Top Face
4
14
Type
16d
Qty
8
Type
16d
100%
7450
115%
1770
100%
33.14
115%
7.87
100%
6260
115%
1485
100%
27.85
115%
6.61
16
16d
16d
7885
1970
35.08
8.76
6625
16d
16d
4390
990
19.53
4.40
3690
1655
29.47
7.36
830
16.41
-- --
10d
10d
4760
-- --
21.17
-- --
3.69
3235
-- --
14.39
2-1/2
-- --
NA20D
10d
7680
-- --
34.16
-- --
-- --
5225
-- --
23.24
-- --
-- --
2-1/2
16d
16d
5510
990
24.51
2-1/2
-- --
10d
10d
4760
-- --
21.17
4.40
4630
830
20.60
3.69
-- --
3235
-- --
14.39
10
2-1/2
-- --
NA20D
10d
7680
-- --
34.16
-- --
-- --
5225
-- --
23.24
-- --
NA20D
NA20D
5075
810
22.58
3.60
10
16d
16d
6575
1480
29.25
6.58
3605
750
16.04
3.34
5525
1245
24.58
-- --
10d
10d
4760
-- --
21.17
-- --
5.54
3235
-- --
14.39
-- --
NA20D
10d
7680
-- --
34.16
-- --
-- --
5225
-- --
23.24
-- --
-- --
2-1/2
NA20D
NA20D
5075
810
22.58
3.60
3605
750
16.04
3.34
2-1/2
-- --
2-1/2
12
16d
16d
7025
1480
31.25
6.58
5900
1245
26.25
5.54
11-1/8 2-1/2
10
2-1/2
-- --
NA20D
10d
7680
-- --
34.16
-- --
5225
-- --
23.24
-- --
2-1/2
-- --
2-1/2
14
16d
16d
7450
1770
33.14
7.87
6260
1485
27.85
6.61
13-1/8 2-1/2
10
2-1/2
-- --
NA20D
10d
7680
-- --
34.16
-- --
5225
-- --
23.24
-- -7.36
11
13
12
5-1/2
2-1/2
-- --
2-1/2
16
16d
16d
7885
1970
35.08
8.76
6625
1655
29.47
3/10
5-1/2
15-1/8 2-1/2
15
10
2-1/2
-- --
NA20D
10d
7680
-- --
34.16
-- --
5225
-- --
23.24
-- --
3/10
7-1/2
5-3/8
10
2-1/2
-- --
NA20D
10d
7680
-- --
34.16
-- --
5225
-- --
23.24
-- --
2-1/2
8x8
KHW88
HW88
3/10
7-1/2
7-1/8
2-1/2
10
2-1/2
-- --
NA20D
10d
7680
-- --
34.16
-- --
5225
-- --
23.24
-- --
8 x 10
KHW810
HW810
3/10
7-1/2
9-1/8
2-1/2
10
2-1/2
-- --
NA20D
10d
7680
-- --
34.16
-- --
5225
-- --
23.24
-- --
8 x 12
KHW812
HHB812, HW812
3/10
7-1/2
11-1/8 2-1/2
10
2-1/2
NA20D
10d
7680
-- --
34.16
-- --
5225
-- --
23.24
-- --
8 x 14
KHW814
HHB814, HW814
3/10
7-1/2
13-1/8 2-1/2
10
2-1/2
NA20D
10d
7680
-- --
34.16
-- --
5225
-- --
23.24
-- --
8 x 16
KHW816
HHB816, HW816
3/10
7-1/2
15-1/8 2-1/2
10
2-1/2
NA20D
10d
7680
-- --
34.16
-- --
5225
-- --
23.24
-- --
Glulam Sizes5
2-1/2 glulam
KHW26
3/10
2-11/16
specify
10
2-1/2
-- --
NA20D
10d x 1-1/2
7625
-- --
33.92
-- --
5185
-- --
23.06
-- --
3-1/8 glulam
KHW3
HW3.25
-- --
3/10
3-1/4
specify
10
2-1/2
-- --
NA20D
10d
7625
-- --
33.92
-- --
5185
-- --
23.06
-- --
5-1/8 glulam
KHW5
HW5.25
3/10
5-1/4
specify 2-1/2
10
2-1/2
-- --
NA20D
10d
7625
-- --
33.92
-- --
5185
-- --
23.06
-- --
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) KHW and SWH products do not provide uplift resistance.
3) Minimum nail embedment shall be 8 nail diameters (typ).
4) KHW Glulam load values are based on 560 psi perpendicular to grain loading.
5) Consult USP for additional Glulam sizes.
6) NAILS:
$# $$# $
$#$!"
New products or updated product information are designated in red font.
2 1/2
Hangers
1-800-328-5934 www.USPconnectors.com
USP2240-131
101
NEW
Materials: 18 gauge
Finish: G90 galvanizing
Codes: Load values are derived from data submitted to
various North American building code evaluators.
TF
Raised
dimple allows
30 to 45
nailing
JH20
Uses standard
length nails
Fastener Schedule2,3,4
Dimensions (in)
Header
USP
Steel
Joist Size Stock No. Ref. No. Gauge
)
JH20
-- --
18
Factored Resistance
Joist
DF-L
Qty Qty
TF
Size
Type
Qty
Type
)
10d
10d
)
10d
10d
)
12
10d
10d
-- --
)
-- --
14
10d
10d
Unit
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
100%
3565
15.86
3565
15.86
4750
21.13
3770
16.77
115%
1065
4.74
1065
4.74
2415
10.74
2415
10.74
Hangers
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
$&$%#' %+%!
, %#!&%!$%!#%#&$$ %!#%!'%%!$
4) NAILS: $# -)-! $ #$ ) -! *&$(# !! $#$"(% !#&%! !
("#!&%$!#&"%"#!&% !#%! #$ % red font.
102
S-P-F
1-800-328-5934 www.USPconnectors.com
100%
2745
12.21
3060
13.61
3375
15.01
3375
15.01
115%
955
4.25
955
4.25
1715
7.63
1715
7.63
Installation:
Use all specified fasteners. See Product Notes, page 10.
Joist nails must be driven at a 30 to 45 angle through the joist
or truss into the header to achieve listed loads. Standard length
double shear nails must be used to achieve listed load
values.
If installing in top mount configuration, field bend top flange over
header.
16d sinkers (9 gauge x 3 1/4) may be used where 10d common
are specified with no load reduction.
3&4
Fastener Schedule2,3
Dimensions (in)
Header
Rafter
Width
USP
Stock No.
1-1/2
LSSH15-TZ
1-1/2
1-3/4
LSSH210
LSSH179
2 - 2-1/8
LSSH20
2-1/4 - 2-5/16
2-1/2
2-5/8
3
3-1/2
LSSH23
LSSH25
LSSH26
LSSH31
LSSH35
1-1/2
LSSH15-TZ
1-1/2
1-3/4
LSSH210
LSSH179
LSSH20
2-1/4 - 2-5/16
2-1/2
2-5/8
3
3-1/2
LSSH23
LSSH25
LSSH26
LSSH31
LSSH35
LSU26, LSU26Z,
LSSU28, LSSU28Z
LSSU210
LSSUI25
LSSUI2.06,
LSSU2.1
LSSUI35
LSSUH310
-- -LSSU210-2
LSSU410
LSU26, LSU26Z,
LSSU28, LSSU28Z
LSSU210
LSSUI25
LSSUI2.06,
LSSU2.1
LSSUI35
LSSUH310
-- -LSSU210-2
LSSU410
W2
W1
W2
Slope to
45 up
or down
LSSH35
Factored Resistance
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
Steel
Gauge
W1
W2
18
1-9/16
1-3/4
18
18
1-9/16 1-3/4
1-13/16 1-5/8
18
Rafter
Typical LSSH179
installation
2-1/8
2-1/2
5-1/16
Type
100%
115%
100%
115%
100%
115%
100%
115%
1640
1395
7.30
6.21
1165
995
5.18
4.43
8-13/16 10
8-13/16 10
10d
10d
7
7
10d x 1-1/2
10d x 1-1/2
2775
2775
2005
2005
12.34
12.34
8.92
8.92
1970
1970
1425
1425
8.76
8.76
6.34
6.34
8-13/16 10
10d
10d x 1-1/2
2620
1845
11.65
8.21
1860
1310
8.27
5.83
18
16
16
16
16
2620
4260
4260
5230
5230
1845
2250
2250
2985
2985
11.65
18.95
18.95
23.27
23.27
8.21
10.01
10.01
13.28
13.28
1860
3025
3025
3715
3715
1310
1600
1600
2120
2120
8.27
13.46
13.46
16.53
16.53
5.83
7.12
7.12
9.43
9.43
18
1-9/16
18
18
1-9/16 1-3/4
1-13/16 1-5/8
1-3/4
1340
1395
5.96
6.21
950
995
4.23
4.43
8-13/16 10
8-13/16 10
5-1/16
7
7
10d x 1-1/2
10d x 1-1/2
2775
2775
2005
2005
12.34
12.34
8.92
8.92
1970
1970
1425
1425
8.76
8.76
6.34
6.34
18
2-1/8
2-1/2
8-13/16 10
10d
10d x 1-1/2
2620
1845
11.65
8.21
1860
1310
8.27
5.83
18
16
16
16
16
2-5/16
2-9/16
2-11/16
3-1/8
3-9/16
2-3/8
2-3/4
2-5/8
3-3/4
3-1/2
8-13/16
8-13/16
8-13/16
8-13/16
8-13/16
10d
16d
16d
16d
16d
7
12
12
12
12
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
2620
2985
2985
3145
3145
1845
2250
2250
2985
2985
11.65
13.28
13.28
13.99
13.99
8.21
10.01
10.01
13.28
13.28
1860
2120
2120
2235
2235
1310
1600
1600
2120
2120
8.27
9.43
9.43
9.94
9.94
5.83
7.12
7.12
9.43
9.43
10
14
14
14
14
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) NAILS:G[QDLOVDUHGLD[ORQJGQDLOVDUHGLD[ORQJGQDLOVDUHGLD[ORQJ
1HZSURGXFWVRUXSGDWHGSURGXFWLQIRUPDWLRQDUHGHVLJQDWHGLQred font.
1-800-328-5934 www.USPconnectors.com
USP2240-131
Hangers
2 - 2-1/8
Ref. No.
103
SKH26R
Right skew
SKH26L
Left skew
Installation:
Use all specified fasteners. See Product Notes, page 10.
The hangers listed are for standard sizes and will accommodate a 40 to 50
skew range.
Most sizes do not require a miter cut for installation. Refer to chart
footnote identified with an asterisk.
Illustrations show left and right skews. (SKH_L = skewed left; SKH_R =
skewed right)
For I-Joist installations, web stiffeners are required.
Refer to illustration for staggered I-Joist application for double 2, 2 5/16, and
2 1/2 models.
For double I-Joist installations, web stiffeners between I-Joists are required.
Right skew
2x4
2x6-8
2 x 8 - 10 - 12
Hangers
2 x 10 - 12 - 14
USP
Stock No.
SKH24L/R
SKH26L/R
SKH26L/R-GC
SKH28L/R
SKH210L/R
1 3/4 x 9-1/4 - 14
SKH210L/R-GC
SKH1720L/R
1-3/4 x 11-1/4 - 18
SKH1724L/R
2 - 2-1/8 x 9-1/4 - 14
SKH2020L/R
2 - 2-1/8 x 11-1/4 - 18
SKH2024L/R
2-1/4 - 2-5/16 x
9-1/4 - 14
2-1/4 - 2-5/16 x
11-1/4 - 18
3x6-8
3 x 8 - 10 - 12
3 x 10 - 12 - 14
3 x 12 - 14 - 16
2-1/2 x 9-1/4 - 14
SKH2320L/R
SKH2324L/R
SKH36L/R
SKH38L/R
SKH310L/R
SKH312L/R
SKH2520L/R
2-1/2 x 11-1/4 - 16
SKH2524L/R
2-5/8 x 9-1/4 - 14
2-5/8 x 11-1/4 - 16
SKH2620L/R
SKH2624L/R
Ref. No.
SUR/L24
SUR/L26
-- --- -SUR/L210,
SUR/L214
-- -SUR/L1.81/9
SUR/L1.81/11,
SUR/L1.81/14
SUR/L2.06/9,
SUR/L2.1/9
SUR/L2.06/11,
SUR/L2.1/11
SUR/L2.37/9
SUR/L2.37/11,
SUR/L2.37/14
-- --- --- --- -SUR/L2.56/9
SUR/L2.56/11,
SUR/L2.56/14
-- --- --
Typical SKH2520R-2
staggered I-Joist installation
Right skew
2,3
Dimensions (in)
Beam /
Joist Size
Typical SKH26L
installation
Left skew
Left skew
Drive nails
at angle
Factored Resistance
Fastener Schedule
Joist
Header
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
1
Vertical Uplift1 Vertical Uplift1 Vertical Uplift1 Vertical Uplift
Steel
Gauge
16
W
1-9/16
H
3-1/4
D
1-7/8
16
1-9/16
5-1/4
1-7/8
16
1-9/16
7-1/4
1-7/8
16
1-9/16
9-1/4
1-7/8
16
1-13/16
9-1/8
1-7/8
14
14
N16C-GC
10d
10
10
N10-GC
10d x 1-1/2
2905
3515
2910
2910
16
1-13/16
11-1/8
1-7/8
16
10d
10
10d x 1-1/2
4740
16
2-1/8
1-7/8
14
10d
10
10d x 1-1/2
16
2-1/8
11
1-7/8
16
10d
10
16
2-3/8
8-7/8
1-7/8
14
10d
16
2-3/8
10-7/8
1-7/8
16
16
16
16
16
16
2-9/16
2-9/16
2-9/16
2-9/16
2-9/16
4-3/4
6-3/4
8-3/4
10-3/4
8-5/8
1-3/8
1-3/8
1-3/8
1-3/8
1-7/8
6
10
14
16
14
16
2-9/16
10-3/4
1-7/8
16
16
2-11/16 8-11/16
2-11/16 10-11/16
1-7/8
1-7/8
Qty
Type
Qty
4
16d
4
6
16d
6
6 N16C-GC 6
8
16d
10
Type
10d x 1-1/2
10d x 1-1/2
N10-GC
10d x 1-1/2
100%
825
1445
1445
2375
115%
1055
2530
2530
2530
100%
3.67
6.43
6.43
10.56
115%
4.69
11.25
11.25
11.25
100%
585
1025
1025
1685
115%
750
1795
1795
1795
100%
2.60
4.56
4.56
7.50
115%
3.34
7.98
7.98
7.98
10
10d x 1-1/2
2905
2910
12.92
12.94
2065
2065
9.19
9.19
12.92
15.64
12.94
12.94
2065
2495
2065
2065
9.19
11.10
9.19
9.19
2910
21.09
12.94
3365
2065
14.97
9.19
2175
2910
9.68
12.94
1545
2065
6.87
9.19
10d x 1-1/2
4740
2910
21.09
12.94
3365
2065
14.97
9.19
10
10d x 1-1/2
2175
2910
9.68
12.94
1545
2065
6.87
9.19
10d
10
10d x 1-1/2
4740
2910
21.09
12.94
3365
2065
14.97
9.19
16d
16d
16d
16d
10d
6
8
10
10
10
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
1490
2565
3265
3630
3265
2530
2530
2910
2910
2910
6.63
11.41
14.52
16.15
14.52
11.25
11.25
12.94
12.94
12.94
1060
1820
2320
2575
2320
1795
1795
2065
2065
2065
4.72
8.10
10.32
11.45
10.32
7.98
7.98
9.19
9.19
9.19
16
10d
10
10d x 1-1/2
3265
2910
14.52
12.94
2320
2065
10.32
9.19
14
16
10d
10d
10
10
10d x 1-1/2
10d x 1-1/2
3265
3265
2910
2910
14.52
14.52
12.94
12.94
2320
2320
2065
2065
10.32
10.32
9.19
9.19
14
16d
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) NAILS:
104
1-800-328-5934 www.USPconnectors.com
SKH210L/R
2 x 10 - 12 - 14
1-3/4 x 11-1/4 - 18
SKH1724L/R
SUR/L1.81/14
16
1-9/16
9-1/4
1-7/8
16
1-13/16
11-1/8
1-7/8
14
16d
10
10d x 1-1/2
2905
2910
12.92
12.94
2065
2065
9.19
9.19
16
10d
10
10d x 1-1/2
4740
2910
21.09
12.94
3365
2065
14.97
9.19
2 - 2-1/8 x 9-1/4 - 14
SKH2020L/R
16
2-1/8
1-7/8
14
10d
10
10d x 1-1/2
2175
2910
9.68
12.94
1545
2065
6.87
9.19
2 - 2-1/8 x 11-1/4 - 18
SKH2024L/R
16
2-1/8
11
1-7/8
16
10d
10
10d x 1-1/2
4740
2910
21.09
12.94
3365
2065
14.97
9.19
16
2-3/8
8-7/8
1-7/8
14
10d
10
10d x 1-1/2
2175
2910
9.68
12.94
1545
2065
6.87
9.19
16
2-3/8
10-7/8
1-7/8
16
10d
10
10d x 1-1/2
4740
2910
21.09
12.94
3365
2065
14.97
9.19
10.32
D
9.19
SKH2320L/R
SUR/L2.37/9
SKH2324L/R
2-1/2 x 11-1/4 - 16
SKH2524L/R
2-9/16
10-3/4
1-7/8
SKH210R
16
10d
10
SKH2020L/R-2 *
(2) 2 - 2-1/8 x
11-1/4 - 18
SKH2024L/R-2 *
SKH2320L/R-2 *
(2) 2-5/16 x
11-1/4 - 18
SKH2324L/R-2 *
SKH2520L/R-2 *
SKH2524L/R-2 *
2x6-8
2 x 8 - 10 - 12
2 x 10 - 12 - 14
SKHH26L/R
SKHH28L/R
SKHH210L/R
SKHH26L/R-2
SKHH26L/R-2IF
(2) 2 x 6 - 8
(2) 2 x 10 - 12 - 14
4x6-8
4 x 10 - 12 - 14
4 x 14 - 16 - 18
SKHH210L/R-2
SKHH210L/R-2IF
SKHH46L/R
SKHH46L/RIF
SKHH410L/R
SKHH410L/RIF
SKHH414L/R
SKHH414L/RIF
Ref. No.
SUR/L26-2
-- -SUR/L210-2
SUR/L214-2
SUR/L410
SUR/L414
SUR/L46
SUR/L410
SUR/L414
HSUR/L4.12/9,
HSUR/L4.28/9
HSUR/L4.12/11,
HSUR/L4.12/14,
HSUR/L4.12/16,
HSUR/L4.28/11
2910
14.52
12.94
2320
2065
SKHH210L-2
SKHH210L
Fastener Schedule
Header
USP
Stock No.
SKH26L/R-2 *
SKH28L/R-2 *
SKH210L/R-2 *
SKH212L/R-2 *
SKH410L/R *
SKH414L/R *
SKH46L/R *
SKH410L/R *
SKH414L/R *
3265
Dimensions (in)
Beam /
Joist Size
(2) 2 x 6 - 8
(2) 2 x 8 - 10 - 12
(2) 2 x 10 - 12 - 14
(2) 2 x 12 - 14 - 16
3-1/2 x 8 - 14
3-1/2 x 12 - 18
4x6-8
4 x 10 - 12 - 14
4 x 14 - 16 - 18
(2) 2 - 2-1/8 x
9-1/4 - 14
10d x 1-1/2
SKH210L
Copyright 2013 USPStructural Connectors
16
SUR/L2.56/14
2,3
SKH2520R-2
Factored Resistance
Joist
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
Steel
Gauge
16
16
16
16
14
14
14
14
14
W
3-1/16
3-1/16
3-1/16
3-1/16
3-9/16
3-9/16
3-9/16
3-9/16
3-9/16
H
4-1/2
6-1/2
8-1/2
10-1/2
8-1/2
12-1/2
4-3/4
8-1/2
12-1/2
D
1-3/8
1-3/8
1-3/8
1-3/8
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
Qty
6
10
14
16
16
22
10
16
22
Type
16d
16d
16d
16d
16d
16d
16d
16d
16d
Qty
6
8
10
10
10
10
6
10
10
Type
10d
10d
10d
10d
16d
16d
16d
16d
16d
100%
1795
3920
5065
4930
3690
7405
2575
3690
7405
115%
2530
2530
3565
3565
3560
3560
2530
3560
3560
100%
7.98
17.44
22.53
21.90
16.41
32.94
11.45
16.41
32.94
115%
11.25
11.25
15.86
15.90
15.84
15.84
11.25
15.84
15.84
100%
1275
2785
3595
3500
2620
5260
1830
2620
5260
115%
1795
1795
2530
2530
2530
2530
1795
2530
2530
100%
5.67
12.39
15.99
15.60
11.65
23.40
8.14
11.65
23.40
115%
7.98
7.98
11.25
11.25
11.25
11.25
7.98
11.25
11.25
14
4-3/16
9-1/4
3-1/2
14
10d
10
10d
5430
3565
24.15
15.86
3855
2530
17.15
11.25
14
4-3/16
11-1/4
3-1/2
16
10d
10
10d
5055
3560
22.49
15.84
3590
2530
15.97
11.25
14
4-7/8
9-1/4
3-1/2
14
10d
10
10d
5430
3565
24.15
15.86
3855
2530
17.15
11.25
14
4-7/8
11-1/4
3-1/2
16
10d
10
10d
5055
3560
22.49
15.84
3590
2530
15.97
11.25
14
5-1/8
9-1/4
3-1/2
14
10d
10
10d
5430
3565
24.15
15.86
3855
2530
17.15
11.25
14
5-1/8
11-1/4
3-1/2
16
10d
10
10d
5055
3560
22.49
15.84
3590
2530
15.97
11.25
14
14
14
14
14
1-5/8
1-5/8
1-5/8
3-1/16
3-1/16
5-1/8
7
9
5-1/4
5-1/4
3-1/4
3-1/4
4-1/4
2
2
18
26
34
12
12
16d
16d
16d
16d
16d
12
16
20
4
4
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
16d x 2-1/2
16d x 2-1/2
2195
3170
4140
2435
2435
2370
3155
3940
935
935
9.76
14.10
18.42
10.83
10.83
10.54
14.03
17.53
4.16
4.16
1880
2720
3555
2090
2090
2045
2730
3410
805
805
8.36
12.10
15.81
9.30
9.30
9.10
12.14
15.17
3.58
3.58
HSUR/L4.75/9
HSUR/L4.75/11,
HSUR/L4.75/14,
HSUR/L4.75/16
HSUR/L5.12/9
HSUR/L5.12/11,
HSUR/L5.12/14,
HSUR/L5.12/16
-- --- --- -HSUR/L26-2
HSUR/LC26-2
HSUR/L210-2,
HSUR/L214-2
HSUR/LC210-2
HSUR/L46
HSUR/LC46
HSUR/L410
HSUR/LC410
HSUR/L414
HSUR/LC414
14
3-1/16
8-1/2
20
16d
16d x 2-1/2
4060
1400
18.06
6.23
3485
1200
15.50
5.34
14
14
14
14
14
14
14
3-1/16
3-9/16
3-9/16
3-9/16
3-9/16
3-9/16
3-9/16
8-1/2
5-1/4
5-1/4
8-1/2
8-1/2
12-1/2
12-1/2
2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
20
12
12
20
20
26
26
16d
16d
16d
16d
16d
16d
16d
6
6
6
10
10
10
10
16d x 2-1/2
16d
16d
16d
16d
16d
16d
4060
2435
2435
4060
4060
5280
5280
1400
1400
1400
2335
2335
2335
2335
18.06
10.83
10.83
18.06
18.06
23.49
23.49
6.23
6.23
6.23
10.39
10.39
10.39
10.39
3485
2090
2090
3485
3485
4530
4530
1200
1200
1200
2005
2005
2005
2005
15.50
9.30
9.30
15.50
15.50
20.15
20.15
5.34
5.34
5.34
8.92
8.92
8.92
8.92
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) NAILS:
"!
('(
"!
('
(
'
"
('
(
#!$#! $!"##%""
&!$#"!$#!$#!#!"# red font.
Header
USP
Steel
W
Joist Size Stock No. Ref. No. Gauge
LS268
-- -18
1-9/16
2x6-8
LS210
-- -18
1-9/16
LS268
Fastener Schedule2,4
Dimensions (in)
Joist
Typical LS268
installation
3
W
Hangers
Installation:
Use all specified fasteners. See Product Notes, page 10.
The LS can be field adjusted to slopes from 0 to 30 down.
Factored Resistance
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
Qty
7
9
Type
16d
16d
Qty
Type
7 10d x 1-1/2
9 10d x 1-1/2
100%
1370
1765
115%
840
1290
100%
6.09
7.85
115%
3.74
5.74
100%
1180
1520
115%
720
1110
100%
5.25
6.76
115%
3.20
4.94
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) A tie strap is required for all installations when sloped down at 7/12 to 12/12 pitch - use LSTA24 with (4) 10d x 1-1/2 nails per end.
4) NAILS:
1-800-328-5934 www.USPconnectors.com
USP2240-131
105
Header
Hangers
3 1/2
3 1/2
Ref. No.
2x4-6
-- --
1-5/8
5-3/8
2x8
HWUH28
-- --
1-5/8
7-1/8
2 x 10
HWUH210
-- --
1-5/8
9-1/8
2 x 12
HWUH212
-- --
1-5/8
11
2 x 14
HWUH214
-- --
1-5/8
13
2 x 16
HWUH216
-- --
1-5/8
16
3x6
HWUH36
-- --
2-5/8
5-3/8
3x8
HWUH38
-- --
2-5/8
7-1/8
3 x 10
HWUH310
-- --
2-5/8
9-1/8
3 x 12
HWUH312
-- --
2-5/8
11
3 x 14
HWUH314
-- --
2-5/8
13
3 x 16
HWUH316
-- --
2-5/8
16
(2) 2 x 6
HWUH26-2
-- --
3-1/8
5-3/8
(2) 2 x 8
HWUH28-2
-- --
3-1/8
7-1/8
(2) 2 x 10
HWUH210-2
-- --
3-1/8
9-1/8
(2) 2 x 12
HWUH212-2
-- --
3-1/8
11
Qty
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
Type
10d
1/2 x 6 Emb. J-Bolt
10d
1/2 x 6 Emb. J-Bolt
10d
1/2 x 6 Emb. J-Bolt
10d
1/2 x 6 Emb. J-Bolt
10d
1/2 x 6 Emb. J-Bolt
10d
1/2 x 6 Emb. J-Bolt
10d
1/2 x 6 Emb. J-Bolt
10d
1/2 x 6 Emb. J-Bolt
10d
1/2 x 6 Emb. J-Bolt
10d
1/2 x 6 Emb. J-Bolt
10d
1/2 x 6 Emb. J-Bolt
10d
1/2 x 6 Emb. J-Bolt
10d
1/2 x 6 Emb. J-Bolt
10d
1/2 x 6 Emb. J-Bolt
10d
1/2 x 6 Emb. J-Bolt
10d
1/2 x 6 Emb. J-Bolt
Factored Resistance
Joist
Qty
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
DF-L (Lbs)
Type
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
100%
6700
5010
6700
5010
6700
5010
6700
5010
6700
5010
6700
5010
6700
5010
6700
5010
6700
5010
6700
5010
6700
5010
6700
5010
6700
5010
6700
5010
6700
5010
6700
5010
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
100%
29.80
22.29
29.80
22.29
29.80
22.29
29.80
22.29
29.80
22.29
29.80
22.29
29.80
22.29
29.80
22.29
29.80
22.29
29.80
22.29
29.80
22.29
29.80
22.29
29.80
22.29
29.80
22.29
29.80
22.29
29.80
22.29
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) NAILS:
red font.
106
Typical HWUH410
wood-to-masonry installation
HWUH410
Vertical
HWUH26
3 1/2
Fastener Schedule2,3
Dimensions (in)
USP
Stock No.
Typical HWUH410
wood-to-wood installation
10
1-800-328-5934 www.USPconnectors.com
115%
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
100%
4760
3555
4760
3555
4760
3555
4760
3555
4760
3555
4760
3555
4760
3555
4760
3555
4760
3555
4760
3555
4760
3555
4760
3555
4760
3555
4760
3555
4760
3555
4760
3555
115%
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
100%
21.17
15.81
21.17
15.81
21.17
15.81
21.17
15.81
21.17
15.81
21.17
15.81
21.17
15.81
21.17
15.81
21.17
15.81
21.17
15.81
21.17
15.81
21.17
15.81
21.17
15.81
21.17
15.81
21.17
15.81
21.17
15.81
115%
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
Installation:
Use all specified fasteners. See Product Notes, page 10.
NA21 nails are included with hangers where specified.
NA21 nails are not recommended for use with LVL,
PSL, or LSLheaders.
Masonry design load values apply to both solid concrete
tie beams and grout-filled CMU walls.
Alternate installation Use (2) 1/2 x 4 Powers
Fasteners Wedge-Bolts or equal for loads up to 2,400 lbs.
when attaching to CMU. Loads shall not exceed table loads.
Beam/
Joist Size
NEW
Dimensions (in)
Header
Beam/
Joist Size
USP
Stock No.
Ref. No.
(2) 2 x 14
HWUH214-2
-- --
3-1/8
13
(2) 2 x 16
HWUH216-2
-- --
3-1/8
16
4x6
HWUH46
-- --
3-9/16
5-3/8
4x8
HWUH48
-- --
3-9/16
7-1/8
4 x 10
HWUH410
-- --
3-9/16
9-1/8
4 x 12
HWUH412
-- --
3-9/16
11
4 x 14
HWUH414
-- --
3-9/16
13
4 x 16
HWUH416
-- --
3-9/16
16
6x6
HWUH66
-- --
5-1/2
5-3/8
6x8
HWUH68
-- --
5-1/2
7-1/8
6 x 10
HWUH610
-- --
5-1/2
9-1/8
6 x 12
HWUH612
-- --
5-1/2
11
6 x 14
HWUH614
-- --
5-1/2
13
6 x 16
HWUH616
-- --
5-1/2
16
8x6
HWUH86
-- --
7-1/2
5-3/8
8x8
HWUH88
-- --
7-1/2
7-1/8
8 x 10
HWUH810
-- --
7-1/2
9-1/8
8 x 12
HWUH812
-- --
7-1/2
11
8 x 14
HWUH814
-- --
7-1/2
13
8 x 16
HWUH816
-- --
7-1/2
16
Qty
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
Type
10d
1/2 x 6 Emb. J-Bolt
10d
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
NA21
1/2 x 6 Emb. J-Bolt
Factored Resistance
Joist
Qty
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Type
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
DF-L (Lbs)
DF-L (kN)
1
Vertical
Uplift
100%
6700
5010
6700
5010
8625
5010
8625
5010
8625
5010
8625
5010
8625
5010
8625
5010
8625
5010
8625
5010
8625
5010
8625
5010
8625
5010
8625
5010
8625
5010
8625
5010
8625
5010
8625
5010
8625
5010
8625
5010
115%
1240
2035
1240
2035
1240
2035
1240
2035
1240
2035
1240
2035
1240
2035
1240
2035
1240
2035
1240
2035
1240
2035
1240
2035
1240
2035
1240
2035
1240
2035
1240
2035
1240
2035
1240
2035
1240
2035
1240
2035
S-P-F (Lbs)
S-P-F (kN)
115%
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
5.52
9.05
100%
4760
3555
4760
3555
6125
3555
6125
3555
6125
3555
6125
3555
6125
3555
6125
3555
6125
3555
6125
3555
6125
3555
6125
3555
6125
3555
6125
3555
6125
3555
6125
3555
6125
3555
6125
3555
6125
3555
6125
3555
115%
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
1090
1445
100%
21.17
15.81
21.17
15.81
27.25
15.81
27.25
15.81
27.25
15.81
27.25
15.81
27.25
15.81
27.25
15.81
27.25
15.81
27.25
15.81
27.25
15.81
27.25
15.81
27.25
15.81
27.25
15.81
27.25
15.81
27.25
15.81
27.25
15.81
27.25
15.81
27.25
15.81
27.25
15.81
115%
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
4.85
6.43
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) NAILS:!
&% &!
&%
& #$"
%%% !
$ #"! #" #" " !" red font.
Specialty Options Chart refer to Specialty Options pages 210 and 212 for additional details.
Option
Skewed1,3
Sloped Seat2,3
Sloped / Skewed1,2,3
Range
81, 8
81, 8
""),-"!"1+!("4"!
Factored
Resistance
,#1)"),!
,#1)"),!
""),-"!"1+!("4"!
5
Hanger Width
9,/)"00
91,
9
91,
9
% of table load:
!!OS, +!
/&$%1(R) ,/)"#1(L),
1,-/,!2 1+2*"/
5
Saddle
,#1)"),!
-"/0&!"
!!SA, +!0!!)"
4&!1%/".2&/"!
1,-/,!2 1+2*"/
5
9
Hangers
Ordering
,#1)"),!
("4"!%+$"/04&1%0("40$/"1"/1%+
7*6%3"))',&01+&)&+$,+,210&!"#)+$"
),-"!,/0),-"!0("4"!%+$"/04&1%0),-"0$/"1"/1%+
7*6%3"!!&1&,+)',&01+&)0
))0),-"!0("4"!,/ ,*&+1&,+0/".2&/""3") 21,+',&01&+))--)& 1&,+0
1-800-328-5934 www.USPconnectors.com
USP2240-131
107
Typical MPH
single ply installation
Installation:
Use all specified fasteners. See Product Notes, page 10.
16d duplex nails are not supplied with MPH hangers.
Place hanger into position on top of concrete block. Install (2) 16d duplex
nails (8 gauge or 0.162 dia. x 312 double head) through the top flange
nail holes. Then continue laying the next course of block.
A minimum of one course shall be laid over hanger top flange and one
course below hanger top flange. Courses adjacent to the top flange shall
be subsequently grouted.
These products do not provide uplift resistance.
2,4
Dimensions (in)
Fastener Schedule
Block
Beam/
Joist Size
2 x 10
2 x 12
2 x 14
2 x 16
(2) 2 x 10
(2) 2 x 12
(2) 2 x 14
(2) 2 x 16
3 x 10
3 x 12
3 x 14
3 x 16
4 x 10
4 x 12
4 x 14
4 x 16
6 x 10
USP
Stock No.
MPH210
MPH212
MPH214
MPH216
MPH210-2
MPH212-2
MPH214-2
MPH216-2
MPH310
MPH312
MPH314
MPH316
MPH410
MPH412
MPH414
MPH416
MPH610
3-1/8 x glulam
5-1/8 x glulam
MPH325
MPH525
Ref. No.
WM210
WM212
WM214
WM216
WM210-2
WM212-2
WM214-2
WM216-2
WM310
WM312
WM314
WM316
WM410
WM412
WM414
WM416
WM610
Steel
Gauge
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
W
1-9/16
1-9/16
1-9/16
1-9/16
3-1/8
3-1/8
3-1/8
3-1/8
2-9/16
2-9/16
2-9/16
2-9/16
3-9/16
3-9/16
3-9/16
3-9/16
5-9/16
-- --- --
12
12
3-1/4
5-1/4
H
L
9-1/4
7
11-1/4
7
13-1/8
7
15-1/8
7
9-1/4
7
11-1/4
7
13-1/8
7
15-1/8
7
9-1/4
7
11-1/4
7
13-1/8
7
15-1/8
7
9-1/4
7
11-1/4
7
13-1/8
7
15-1/8
7
9-1/4
7
Glulam Sizes
specify
7
specify
7
Qty
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Joist
S-P-F
Vertical
Vertical
Type
Qty
Type
16d duplex 2 10d x 1-1/2
16d duplex 2 10d x 1-1/2
16d duplex 2 10d x 1-1/2
16d duplex 2 10d x 1-1/2
16d duplex 2
10d
16d duplex 2
10d
16d duplex 2
10d
16d duplex 2
10d
16d duplex 2 10d x 1-1/2
16d duplex 2 10d x 1-1/2
16d duplex 2 10d x 1-1/2
16d duplex 2 10d x 1-1/2
16d duplex 2
10d
16d duplex 2
10d
16d duplex 2
10d
16d duplex 2
10d
16d duplex 2
10d
Lbs
3745
3745
3745
3745
6165
6165
6165
6165
4665
4665
4665
4665
6165
6165
6165
6165
6165
kN
16.66
16.66
16.66
16.66
27.42
27.42
27.42
27.42
20.75
20.75
20.75
20.75
27.42
27.42
27.42
27.42
27.42
Lbs
3220
3220
3220
3220
5300
5300
5300
5300
4010
4010
4010
4010
5300
5300
5300
5300
5300
kN
14.32
14.32
14.32
14.32
23.58
23.58
23.58
23.58
17.84
17.84
17.84
17.84
23.58
23.58
23.58
23.58
23.58
16d duplex
16d duplex
6165
6165
27.42
27.42
5300
5300
23.58
23.58
2
2
10d
10d
Hangers
Specialty Options Chart refer to Specialty Options pages 210 and 212 for additional details.
Option
Range
Skewed1
6/*6
Factored
Resistance
*!/' 1'0
Ordering
Sloped Seat2
6/*
6
Sloped / Skewed1,2
'*+ /)& 2
108
1-800-328-5934 www.USPconnectors.com
Typical MPH
double ply installation
L
3 3/4
MPH
2 1/2
Materials: 12 gauge
Finish: USP primer
Options: All nominal lumber sizes are available for
rough/full size lumber. See Specialty Options
Chart.
Codes: Load values are derived from data submitted to
various North American building code evaluators.
NEW
Installation:
Use all specified fasteners. See Product Notes, page 10.
Fully grouted and reinforced concrete block or cast-in-place
concrete with a minimum of (1) #5 rebar continuous to
footing with standard hook at bolt locations.
Minimum joist bearing length is 31/2.
3 1/2 Min.
joist bearing
Typical UMH
installation
15 1/2
UMH
Fastener Schedule
Header2,3
USP
Stock No.
Joist4,5
W
(in)
3-5/8
3/4
16
16d
-- --
4-5/8
3/4
16
16d
UMH538
-- --
5-3/8
3/4
16
16d
UMH558
5-5/8
3/4
16
16d
UMH718
-- --
7-1/8
3/4
16
16d
UMH358
UMH458
Ref. No.
Bolt
Qty Dia. (in) Qty
Type
Masonry (Lbs)
2500 psi
Masonry (kN)
2500 psi
Cast-in-Place
Concrete (Lbs)
3000 psi
Cast-in-Place
Concrete (Lbs)
3000 psi
1
1
1
1
Wood Vertical Uplift Vertical Uplift Vertical Uplift Vertical Uplift
Species 100%
115%
100%
115%
100%
115%
100%
115%
DF-L
11875
8205
52.82
36.50 11875
8205
52.82
36.50
S-P-F
8430
5825
37.50
25.91
8430
5825
37.50
25.91
DF-L
11875
8205
52.82
36.50 11875
8205
52.82
36.50
S-P-F
8430
5825
37.50
25.91
8430
5825
37.50
25.91
DF-L
11875
8205
52.82
36.50 11875
8205
52.82
36.50
S-P-F
8430
5825
37.50
25.91
8430
5825
37.50
25.91
DF-L
11875
8205
52.82
36.50 11875
8205
52.82
36.50
S-P-F
8430
5825
37.50
25.91
8430
5825
37.50
25.91
DF-L
11875
8205
52.82
36.50 11875
8205
52.82
36.50
S-P-F
8430
5825
37.50
25.91
8430
5825
37.50
25.91
Hangers
Steel
Gauge
Factored Resistance
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
./")%)$"-/* *) -"/"./-0 /0-"1&/%/1*
5!&*1"-../")"-."!$"*'/.4*-",0'1&/%5(&)&(0("("!(")/
*'/..%''"&)./''"!&)(.*)-31&/%$-*0/"! "''.&) *-!) "1&/%()0# /0-"-.&)./''/&*).+" &#& /&*).
*'/.(0./ *)#*-(/* *-"//"-
&)&(0()&'"("!(")/.%''")&'!&("/"-./3+
5) NAILS:
!)&'.-"
5!&2
5'*)$
"1+-*!0 /.*-0+!/"!+-*!0 /&)#*-(/&*)-"!".&$)/"!&) red font.
1-800-328-5934 www.USPconnectors.com
USP2240-131
109
3 3/4
Materials: 18 gauge
Finish: G90 galvanizing
Installation:
Use all specified fasteners. See Product Notes, page 10.
In panelized construction, installers are allowed to nail through
both the sheathing and the hanger top flange with (1) 10d nail.
The nail should be centered in the top flange and be no closer
than 1/4 from the back or front edge of the top flange.
USP
Steel
Stock No. Ref. No. Gauge
FHD26
-- --
18
5-3/8
1-1/2 specify
Factored Resistance
DF-L
S-P-F
Fastener Schedule
Header
Joist
Top Face
Qty Qty Type Qty
Type
TF4
Unit
Lbs
10d x 1-1/2
kN
100%
1575
7.01
FHD
Uplift
115%
335
1.49
100%
1120
4.98
Uplift
115%
235
1.05
NEW
Typical JPF24
back-to-back installation
Typical JPF24
installation
Installation:
Use all specified fasteners. See Product Notes, page
10.
Diamond holes allow optional header nailing.
Joist nails must be driven at a 30 to 45 angle
through the purlin into the header to achieve listed
loads. Standard length double shear nails must
be used to achieve listed load values.
16d sinkers (9 gauge x 3 1/4 ) may be used where
10d commons are specified with no load reduction.
TF
Raised
dimple allows
30 to 45
nailing
1 1/2
JPF24
Fastener Schedule3,4
Dimensions (in)
Header2
Hangers
Purlin
USP
Steel
Size Stock No. Ref. No. Gauge
JPF24
PF24
20
JPF26
PF26
20
Top
Face
Qty
2
2
2
1-9/16 5-3/8 1-1/16
2
Qty
-- -2
-- -2
TF
Joist
Type Qty Type
10d 2 10d
10d 2 10d
10d 2 10d
10d 2 10d
Factored Resistance
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
Floor
Uplift1
Floor
Uplift1
Floor
Uplift1
Floor
Uplift1
100%
1755
1995
1755
1995
115%
675
890
675
890
100%
7.81
8.87
7.81
8.87
115%
3.00
3.96
3.00
3.96
100%
1245
1420
1245
1420
115%
480
630
480
630
100%
5.54
6.32
5.54
6.32
115%
2.14
2.80
2.14
2.80
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) JPF cannot be used back to back on a single ply header when optional nailing is used.
3) Minimum nail embedment shall be 8 nail diameters (typ).
4) NAILS:
New products or updated product information are designated in red font.
110
1-800-328-5934 www.USPconnectors.com
Uses standard
length nails
3,5
Dimensions (in)
Joist
Size
NEW
TF
NEW
Materials: 20 gauge
Finish: G90 galvanizing
Uplift
Installation:
Use all specified fasteners. See Product Notes, page 10.
Attachs with standard 11/2 joist hanger nails that can be
installed with a positive placement nail gun or be
hand driven.
Other 1-1/2 fasteners with a shear value equal or greater
than a 10d nail may be used.
F2
Typical TUS24
installation
F2
Typical DTUS24
installation
H
H
3"
TUS24S
Fastener Schedule2,3
Header
USP
Steel
Joist Size Stock No. Ref. No. Gauge
Qty
W
20
1-9/16
Download Uplift1
Type
Face Bottom
10d x 1-1/2
-- --
20
1-9/16
10d x 1-1/2
LL915
8d x 1-1/2
2x4-6
saddle
DTUS24
-- --
20
1-9/16
10d x 1-1/2
LL915
Unit
Lbs
kN
Lbs
10d x 1-1/2
kN
Lbs
LL915
kN
Lbs
8d x 1-1/2
kN
Lbs
10d x 1-1/2
kN
Lbs
LL915
kN
Lbs
8d x 1-1/2
kN
Lbs
10d x 1-1/2
kN
Lbs
LL915
kN
100%
980
4.36
980
4.36
980
4.36
980
4.36
980
4.36
980
4.36
980
4.36
980
4.36
980
4.36
115%
955
4.25
955
4.25
955
4.25
955
4.25
955
4.25
955
4.25
955
4.25
955
4.25
955
4.25
S-P-F (Lbs)
F2
115%
385
1.71
385
1.71
385
1.71
1120
4.98
1120
4.98
1120
4.98
1120
4.98
1120
4.98
1120
4.98
Download Uplift1
100%
695
3.09
695
3.09
695
3.09
695
3.09
695
3.09
695
3.09
695
3.09
695
3.09
695
3.09
F2
115% 115%
680
275
3.02 1.22
680
275
3.02 1.22
680
275
3.02 1.22
680
795
3.02 3.54
680
795
3.02 3.54
680
795
3.02 3.54
680
795
3.02 3.54
680
795
3.02 3.54
680
795
3.02 3.54
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) NAILS:$
%
%$
%
$
%
%$
%
#
%$
%
#"! "!"!! ! red font.
1-800-328-5934 www.USPconnectors.com
USP2240-131
Hangers
8d x 1-1/2
TUS24
Type
8d x 1-1/2
LL915
2x4-6
saddle
DF-L (Lbs)
Qty
Face Bottom
Factored Resistance1
Joist
8d x 1-1/2
-- --
TUS24
DTUS24
Dimensions (in)
TUS24S
2x4-6
Bottom
View
111
NEW
TF
TF
H
H
provides a
witness hole
W
W
Typical JDS26
installation
Raised dimple
allows 30 to
45 nailing
JDS24S
1 3/4
Header
Starburst prong
for temporary
attachment to
truss
Typical JDS24S
installation
JDS26-175
installation
JDS26
(JDS24 similar)
JDS26-175
Fastener Schedule2,3
Dimensions (in)
Hangers
Header
Purlin
Size
2x4
2x6
2x4
saddle
2x6
saddle
USP
Stock No.
JDS24S Min
JDS24S Max
JDS26S Min
JDS26S Max
JDS24 Min
JDS24 Max
JDS26-175
JDS26 Min
JDS26 Max
Steel
Ref. No. Gauge
PF24A
18
PF26A
18
PFD24
18
-- --
18
PFD26
18
Each Purlin
TF
Qty
1
2
1
1-9/16 5-1/2 3/4
2
2
1-9/16 3-1/2 1-9/16
4
1-9/16 5-7/16 1-3/4
2
2
1-9/16 5-1/2 1-9/16
4
3/4
Qty
2
-- -2
-- -4
-- -4
4
-- --
Factored Resistance
DF-L (Lbs)
DF-L (kN)
Type
Qty
Type
10d x 1-1/2 2 10d x 1-1/2
10d x 1-1/2 2
10d
10d x 1-1/2 4 10d x 1-1/2
10d x 1-1/2 4
10d
10d x 1-1/2 2 10d x 1-1/2
10d x 1-1/2 2
10d
10d x 1-1/2 4 10d x 1-1/2
10d x 1-1/2 4 10d x 1-1/2
10d x 1-1/2 4
10d
100%
785
945
905
1365
1575
1890
1805
1805
2735
115%
340
640
665
730
685
1285
1330
1330
1465
100%
3.49
4.20
4.03
6.07
7.01
8.41
8.03
8.03
12.17
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) NAILS:
red font.
112
Uses standard
length nails
S-P-F (Lbs)
S-P-F (kN)
Top Face
1-9/16 3-1/2
Raised dimple
allows 30 to
45 nailing
1-800-328-5934 www.USPconnectors.com
115%
1.51
2.85
2.96
3.25
3.05
5.72
5.92
5.92
6.52
100%
560
670
640
970
1120
1340
1280
1280
1940
115%
245
455
470
520
485
910
945
945
1040
100%
2.49
2.98
2.85
4.31
4.98
5.96
5.69
5.69
8.63
115%
1.09
2.02
2.09
2.31
2.16
4.05
4.20
4.20
4.63
Installation:
Use all specified fasteners. See Product Notes, page 10.
Joist nails must be driven at a 30 to 45 angle through the
purlin into the header to achieve listed loads. Standard length
double shear nails must be used to achieve listed load
values.
EWP Hangers
EWP Hanger Selector Guide
Style
Supported Member
Supporting Member
5,420 - 6,735
5,420 - 6,735
3,848 - 4,782
-- --
9,025
9,025
6,408
-- --
4,545 - 7,215
4,545 - 7,215
3,225 - 5,123
-- --
5,315 - 8,460
5,315 - 8,460
3,775 - 6,005
-- --
11,540
11,540
8,193
-- --
HD
14
HDQ-IF
14
14
12
THDH
12
TFL
18
18
16
12
TFI
16
BPH
12
MPH
PHXU
12
7 - Top Flange,
10 - Stirrup
7
HLBH
HGU
KLEG 1
KMEG 1
KHHB
7
Flange,
7
KGB
KHGB
LGU
7
3 - Top Flange,
7 - Stirrup
3 - Top Flange,
7 - Stirrup
3 - Top Flange,
7 - Stirrup
3 - Top Flange,
7 - Stirrup
3 - Top Flange,
7 - Stirrup
3 - Top Flange,
7 - Stirrup
10
MGU
10
18
16
KEG
KGLT
KHGLT
KGLS
KHGLS
KGLST
KHGLST
LSSH
8,843 - 9,787
-- --
9,365 - 13,355
-- --
Masonry
DF-L
SPF
LVL
Masonry
-- --
Glulam
I-Joist
-- --
2,350 - 4,867
Truss
Dimensional Wood
2,166 - 3,720
3,310 - 6,855
Glulam
3,050 - 5,240
3,310 - 6,855
Truss
3,050 - 5,240
Welded
Formed
Sloped
Skewed
16
PHM
Slope / Skew
12
THO
Glulam
16
HUS
THD
Top
Mount
Face
Mount
I-Joist
THF
Steel
Gauge
18
Top Mount
USP
Series
Face Mount
Hanger
Type
2,370
2,495
1,771
-- --
1,935 - 3,910
1,645 - 4,450
1,170 - 3,160
-- --
1,485 - 3,355
1,690 - 4,820
1,200 - 3,425
-- --
3,355 - 5,090
6,005 - 9,500
4,265 - 6,745
-- --
3,685 - 4,675
4,190 - 5,315
2,975 - 3,775
-- --
4,415 - 5,300
3,780 - 5,055
2,865 - 4,725
-- --
-- --
-- --
-- --
3,745 - 6,165
5,090 - 5,395
4,125 - 4,880
4,125 - 4,880
-- --
6,370 - 9,575
6,370 - 7,610
4,420 - 5,170
-- --
14,725 - 15,295
13,825
12,840
15,060
15,060
12,950
-- --
17,555
17,555
15,095
-- --
7,035
7,035
5,910
-- --
9,300
9,300
7,810
-- --
-- --- --
-- --
10,845
10,845
9,110
-- --
10,865
10,865
9,125
-- --
-- --
-- --
-- --
-- --
-- --
10,760
10,760
7,640
17,465
17,465
12,400
-- --
1,340 - 2,775
1,340 - 2,775
950 - 1,970
-- --
2,985 - 5,230
2,985 - 5,230
2,120 - 3,715
-- --
EWP Hangers
Header Material
-- --
1) KEG, KLEG, KMEG hangers assume factored resistences with top flange.
New products or updated product information are designated in red font.
1-800-328-5934 www.USPconnectors.com
USP2240-131
113
EWP Hangers
EWP Hangers
HD Series
Medium capacity hanger for LVL, LSL, and PSL beams.
THF
HD
HDQIF
HUS Series
Medium capacity hanger for LVL, LSL, and PSL beams with deep seat.
THD Series
Medium-to-heavy capacity hanger for LVL, LSL, and PSL beams.
THDH Series
Heavy capacity hanger for LVL, LSL, and PSL beams.
HUS
THD
THDH
THO Series
Light-to-medium capacity top mount hanger.
TFI Series
Medium capacity I-Joist hanger.
BPH Series
Medium capacity top mount hanger for LVL, LSL, and PSL beams.
TFL
THO
TFI
BPH
HLBH
PHM
HLBH Series
Heavy capacity hanger for LVL, LSL, and PSL beams.
PHM Series
Medium capacity welded hanger for LVL, LSL, and PSL beams with
7 gauge top flanges.
PHXU Series
Medium capacity formed hanger for LVL, LSL, and PSL beams with
uplift capacity.
MPH Series
Medium capacity masonry hanger for I-Joists, LVL, LSL, and
PSL beams.
PHXU
114
1-800-328-5934 www.USPconnectors.com
MPH
HDQIF Series
Inverted flange medium capacity hanger for LVL, LSL, and PSL beams.
EWP Hangers
TMP Series
Adjustable for pitches from 1/12 to 6/12.
TMPH Series
Adjustable for pitches from 6/12 to 14/12.
TMP
EWP Hangers
Adjustable Rafter-to-Plate
Connectors. . . . . . . . . . . . . . . . . . . Page 143
TMPH
LSSH
GHF Series
Face mount glulam hanger fastens with WS wood screws.
KEG, KLEG, & KMEG Series
Top flange glulam hanger fastens with bolts.
GHF
KLEG
KGLT
KGLS
1-800-328-5934 www.USPconnectors.com
KHHB
USP2240-131
115
EWP Hangers
Backer Blocks
The thickness of the hanger metal and nail heads on top mount hangers must be evaluated for the effect on
subsequent sheathing. Ensure that the top mount hanger is installed so the flanges of the hanger are not
over-spread which tends to elevate the supported I-Joist causing uneven floor surfaces and squeaking. Similarly, ensure that
the hanger is installed plumb such that the face flanges of the hanger are mounted firmly against the
wide-face surface of the header.
Flush framing
Correct Slant Nail Installation
Hanger over-spread
! Wrong Angle
Always secure
wood I-Joist using
10d x 1 1 2
nail driven at a
30 to 45 angle
and firmly seated
116
1-800-328-5934 www.USPconnectors.com
Fasteners
maximum gap
Joist
depth
60% min. of
joist depth
EWP Hangers
(Top flange support requirements can be verified in this sections charts under the Web Stiffener Reqd. column.)
Nailer Installations
The nailer must be sized to fit the support width as shown and be of sufficient thickness
to satisfy recommended top flange nailing requirements. A design professional must
specify nailer attachment to steel beams.
1/4
(6.35
mm)
Max.
! Too Narrow
Top flange not fully supported can
cause nail breakout. Or, by fully
supporting top flange, hanger is
tilted back, causing lifting of carried
member which results in uneven
surfaces and squeaky floors.
! Too Wide
Loading can cause cross grain
breaking of nailer. The
recommended nailer overhang
is 1 4 maximum per side.
1-800-328-5934 www.USPconnectors.com
! Too Thin
Top flange nailing cannot fully
penetrate nailer, causing reduced
factored resistance. Never use
hangers which require multiple face
nails since the factored resistance
are dependent on all nail holes being
used.
USP2240-131
117
EWP Hangers
Option
Range
Additional diamond
nail holes for
maximum nailing
Standard round
nail holes for
minimum nailing
THF single
Dimple allows
30 to 45
nailing
Sloped Seat2,3
Sloped / Skewed1,2,3
Inverted Flange
Not available in
!
Factored
Resistance
Ordering
Add IF,
to product number.
Example: THF23925IF
THF double
D
Raised Dimple
nail holes allow
30 to 45
nailing into
I-Joist bottom
flange.
Seat Cleat
helps lock
I-Joist into place
for
positive seating
and nailing ease.
1) Skewed hangers with skews greater than 15 may have all joist nailing on outside flange.
2) Sloped or sloped / skewed hangers with slopes greater than 15 may have additional joist nails.
3) All sloped, skewed, or combinations require bevel cut on joist in all applications.
4) Modifications to THF hangers do not feature seat cleats.
Designed to to support LVL, LSL, and PSL beams and headers in medium load conditions.
Materials:
Finish:
Options:
Codes:
Installation:
Use all specified fasteners. See Product Notes, page 10.
Drive bend line nails into header at 45 to achieve listed loads
Typical HD
bend line nail installation
Specialty Options Chart refer to Specialty Options pages 210 to 211 for additional details.
Option
Range
118
1,3
Skewed
Sloped Seat
2,3
Sloped / Skewed
1,2,3
Inverted Flange
Not available in
100% of table load.
65% of table load when
nailing into the support
members end grain.
Factored
Resistance
Ordering
Typical HD
installation
Bend line
nailing
Add IF,
to product number.
Example: HD410IF
1) Skewed hangers with skews greater than 15 may have all joist nailing on outside flange.
2) Sloped or sloped / skewed hangers with slopes greater than 15 may have additional joist nails.
3) All sloped, skewed, or combinations require bevel cut on joist in all applications and web stiffeners with I-joists.
Hangers for square-cut joists are available as a Custom. Further reductions in allowable loads may apply.
4) Modifications of HD hangers may be manufactured as hot rolled, welded, or primed.
1-800-328-5934 www.USPconnectors.com
HD
EWP Hangers
Materials: 14 gauge
Finish: G90 galvanizing
Codes: Load values are derived from data
submitted to various North American
building code evaluators.
Installation:
Use all specified fasteners. See Product Notes, page 10.
WS15 and WS3 WoodScrews are supplied with
HDQIF hangers.
Up to 3/4
gap
Typical HDQIF
installation
HDQIF
Designed for medium load conditions. Extended 3 deep seat provides extra truss bearing.
Materials: 16 gauge
Finish: G90 galvanizing
Codes: Load values are derived from data submitted to various North American
building code evaluators.
Installation:
Use all specified fasteners. See Product Notes, page 10.
Joist nails must be driven at a 30 to 45 angle through
the joist into the header to achieve listed loads.
Typical HUS
installation
2
Dimple allows
30 to 45
nailing
H
Typical HUS
double shear installation
1-800-328-5934 www.USPconnectors.com
HUS
USP2240-131
119
EWP Hangers
Installation:
Use all specified fasteners. See Product Notes, page 10.
THD Drive bend line nails into header at 45 to achieve listed loads.
THDH Drive joist nails into header at 30 to 45 to achieve listed loads.
Some model
designs may
vary from
illustration
shown
Typical THD
installation
Typical THDH
double shear installation
THD single
W
Typical THD
bend line nail installation
3
Left
flange
Specialty Options Chart refer to Specialty Options pages 210 to 211 for additional details.
Option
Range
Factored
Resistance
USP Series
Skewed
Sloped Seat
2,3
Sloped / Skewed
1,2,3,4
THD
81, 8
81, 8
""),-"!"1+!("4"!
THDH
81, 8
81, 8
""),-"!"1+!("4"!
THD
,#1)"3)2"
,#1)"3)2"
,#1)"3)2"
,#1)"3)2"
,#1)"3)2"
,#1)"2-)
)2"
THDH
Ordering
1,3
THD
THDH
,#1)"3)2"
,#1)"2-)
)2"
!!+$)"/".2&/"!
+!/&$%1(R) ,/)"#1(L),
1,-/,!2 1+2*"/
5*-)"
!!0),-"/".2&/"!
+!2-(U) ,/!,4+(D),
1,-/,!2 1+2*"/
5*-)"
""),-"!"1+!("4"!
5*-)"
Inverted Flange
,13&))"&+4&!1%0
)"001%+9&!1%0$/"1"/
+%3",+"#)+$"&+3"/1"!
N/A
,#1)"3)2"
,#1)"3)2"4%"+
+&)&+$&+1,1%"02--,/1
*"*"/0"+!$/&+
D Right
flange
THD double
or larger
2 1/2
N/A
!!1IF, ,+"#)+$"
/&$%1(R) +!)"#1(L),
5*-)"
N/A
("4"!%+$"/04&1%0("40$/"1"/1%+
7*6%3"))',&01+&)&+$,+,210&!"#)+$"))0("4"!%+$"/0%3"+&)0,+,+"0&!",+)6
),-"!,/0),-"!0("4"!%+$"/04&1%0),-"0$/"1"/1%+
7*6%3"!!&1&,+)',&01+&)0
*,!")0))0),-"!0("4"!,/ ,*&+1&,+0/".2&/""3") 21,+',&01&+))--)& 1&,+0
*,!")0))0),-"!0("4"!,/ ,*&+1&,+0/".2&/""3") 21,/0.2/" 21,+',&01&+))--)& 1&,+0
W
Dimple allows
30 to 45
nailing
THDH26-2
120
1-800-328-5934 www.USPconnectors.com
THF15925 Min
1-1/2 x 9 -1/4 - 9-1/2
THF15925 Max
THF15112 Min
1-1/2 x 11-1/4 - 11-7/8
Copyright 2013 USPStructural Connectors
THF15112 Max
1-1/2 x 14
1-5/8 x 9-1/4 - 9-1/2
1-5/8 x 11-1/4 - 12
1-5/8 x 14
1-3/4 x 9-1/4 - 9-1/2
THF15140 Min
THF15140 Max
THF16925 Min
THF16925 Max
THF16112 Min
THF16112 Max
THF16140 Min
THF16140 Max
THF17925 Min
THF17925 Max
THF17112 Min
Ref. No.
IUS1.56/9.5,
LF159
IUT29,
MIU1.56/9
IUS1.56/11.88,
LF1511
IUT211,
MIU1.56/11
LF1514
IUT214
-- -IUT1.68/9
-- -IUT1.68/11
-- -IUT1.68/14
IUS1.81/9.5,
LF179
IUT9
IUS1.81/11.88,
LF1711
THF17112 Max
IUT11
1-3/4 x 14
THF17140 Min
IUS1.81/14,
LF1714
1-3/4 x 16
THF17140 Max
THF17157
2 - 2-1/8
x 9-1/4 - 9-1/2
THF20925 Min
2 - 2-1/8
x 11-1/4 - 11-7/8
THF20112 Min
2 - 2-1/8 x 14
THF20140 Min
THF20925 Max
THF20112 Max
THF20140 Max
2 - 2-1/8 x 16
THF20157
2-1/4 - 2-5/16
x 9-1/4 - 9-1/2
THF23925
2-1/4 - 2-5/16
x 11-1/4 - 11-7/8
THF23118
2-1/4 - 2-5/16 x 14
THF23140
2-1/4 - 2-5/16 x 16
THF23160
2-1/4 - 2-5/16 x 18 - 28
THF23180
THF25925
THF25112
IUT14
IUS1.81/16
IUS2.06/9.5,
LF209
IUT2.06/9
IUS2.06/11.88,
LF2011
IUT2.06/11
IUS2.06/14,
LF2014
IUT2.06/14
IUS2.06/16,
IUT2.06/16
LF239,
HU359,
IUS2.37/9.5,
IUT3510,
MIU2.37/9,
U3510/14
LF2311,
HU3511,
IUS2.37/11.88,
IUT3512,
MIU2.37/11
LF2314,
HU3514,
IUS2.37/14,
IUT3514,
MIU2.37/14
HU3516/22,
IUS2.37/16,
IUT3516,
MIU2.37/16
HU3524/30,
MIU2.37/18,
MIU2.37/20
LF259,
IUS2.56/9.5,
IUT310,
MIU2.56/9
LF2511,
IUS2.56/11.88,
IUT312,
MIU2.56/11
--
--
Steel Gauge
USP
StockNo.
Fastener Schedule2,3
Header
Joist
Dimensions (in)
18
18
W
1-1/2
1-1/2
H
9-1/16
11-1/16
13-1/2
1-1/2
--
18
1-5/8
--
18
1-5/8
11
--
18
1-5/8
13-7/16
--
18
1-3/4
8-15/16
--
18
1-3/4
1-3/4
10-15/16
13-3/8
Uplift1
Vertical
Uplift1
Type
100%
115%
100%
115%
100%
115%
100%
115%
10d
10dx1-1/2
3050
525
13.57
2.34
2166
373
9.63
1.66
12
10d
10dx1-1/2
3225
525
14.35
2.34
2290
373
10.19
1.66
10d
10dx1-1/2
3050
525
13.57
2.34
2166
373
9.63
1.66
16
10d
10dx1-1/2
4135
525
18.39
2.34
2936
373
13.06
1.66
12
20
8
12
8
16
12
20
10d
10d
10d
10d
10d
10d
10d
10d
2
2
2
2
2
2
2
2
10dx1-1/2
10dx1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
3815
4045
3050
3225
3050
4135
3815
4045
525
525
525
525
525
525
525
525
16.97
17.99
13.57
14.35
13.57
18.39
16.97
17.99
2.34
2.34
2.34
2.34
2.34
2.34
2.34
2.34
2709
2872
2166
2290
2166
2936
2709
2872
373
373
375
375
375
375
375
375
12.05
12.78
9.63
10.19
9.63
13.06
12.05
12.78
1.66
1.66
1.67
1.67
1.67
1.67
1.67
1.67
1.66
10dx1-1/2
3050
525
13.57
2.34
2166
373
9.63
10dx1-1/2
3225
525
14.35
2.34
2290
373
10.19
1.66
10d
10dx1-1/2
3050
525
13.57
2.34
2166
373
9.63
1.66
16
10d
10dx1-1/2
4135
525
18.39
2.34
2936
373
13.06
1.66
12
10d
10dx1-1/2
3815
525
16.97
2.34
2709
373
12.05
1.66
20
24
10d
10d
2
2
10dx1-1/2
10dx1-1/2
4045
4435
525
525
17.99
19.73
2.34
2.34
2872
3149
373
373
12.78
14.01
1.66
1.66
1.66
--
18
8-7/8
11-3/16
Vertical
10d
3-1/2
2-1/8
Uplift1
10d
15-3/4
18
Vertical
18 1-13/16
--
Uplift1
12
--
2-1/8
Vertical
18
18
--
--
Factored Resistance
DF-L Header (Lbs)
EWP Hangers
Joist Size
10d
10dx1-1/2
3050
525
13.57
2.34
2166
373
9.63
12
10d
10dx1-1/2
3225
525
14.35
2.34
2290
373
10.19
1.66
10d
10dx1-1/2
3050
525
13.57
2.34
2166
373
9.63
1.66
16
10d
10dx1-1/2
4135
525
18.39
2.34
2936
373
13.06
1.66
12
10d
10dx1-1/2
3815
525
16.97
2.34
2709
373
12.05
1.66
--
18
2-1/8
13-1/4
20
10d
10dx1-1/2
4045
525
17.99
2.34
2872
373
12.78
1.66
--
18
2-1/8
15-3/4
3-3/8
24
10d
10dx1-1/2
4435
525
19.73
2.34
3149
373
14.01
1.66
--
18
2-5/16
9-3/16
2-1/2
12
10d
10dx1-1/2
3310
335
14.72
1.49
2350
238
10.45
1.06
--
18
2-5/16
11-3/16
2-1/2
14
10d
10dx1-1/2
3310
720
14.72
3.20
2350
511
10.45
2.27
--
16
2-5/16
13-1/2
2-1/2
18
10d
10dx1-1/2
4405
720
19.60
3.20
3128
511
13.91
2.27
--
16
2-5/16
15-9/16
2-1/2
22
10d
10dx1-1/2
4405
720
19.60
3.20
3128
511
13.91
2.27
16
2-5/16
17-1/8
2-1/2
24
10d
10dx1-1/2
6235
2435
27.74
10.83
4427
1729
19.69
7.69
--
18
2-1/2
9-1/8
2-1/2
12
10d
10dx1-1/2
3310
335
14.72
1.49
2350
238
10.45
1.06
--
18
2-1/2
11-1/8
2-1/2
14
10d
10dx1-1/2
3310
720
14.72
3.20
2350
511
10.45
2.27
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) NAILS
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
H
USP2240-131
121
THF25140
2-1/2 x 16
THF25160
2-1/2 x 18 - 24
THF25160
THF26925
THF26112
THF26140
THF26160
THF15925-2
THF15112-2
THF15140-2
THF16925-2
THF16112-2
THF16140-2
3-1/2 x 9-1/4 - 14
THF35925
3-1/2 x 11-7/8 - 16
THF35112
3-1/2 x 14 - 20
THF35140
3-1/2 x 16 - 22
THF17157-2
3-1/2 x 16 - 22
THF35157
3-1/2 x 18 - 26
THF35165
THF20925-2
4 - 4-3/16
x 11-1/4 - 11-7/8
THF20112-2
4 - 4-3/16 x 14
THF20140-2
4-1/2 - 4-5/8
x 9-1/4 - 14
4-1/2 - 4-5/8
x 11-1/4 - 16
LF3511,
IUS3.56/11.88,
IUT412
LF3514,
IUS3.56/14,
IUT414
-- -IUS3.56/16,
IUT416
-- -HU4.12/9,
HU4.28/9,
HU4.75/9,
MIU4.12/9,
MIU4.28/9
HU4.12/11,
HU4.28/11,
HU4.75/11,
MIU4.12/11,
MIU4.28/11
MIU4.12/14,
MIU4.12/16,
MIU4.28/14,
MIU4.28/16
Factored Resistance
Steel Gauge
2-1/2 x 14
Ref. No.
IUT313
LF2514,
IUS2.56/14,
IUT314,
MIU2.56/14
IUS2.56/16,
IUT316,
MIU2.56/16,
MIU2.56/18,
MIU2.56/20
IUS2.56/16,
IUT316,
MIU2.56/16,
MIU2.56/18,
MIU2.56/20
IUT2.68/10
IUT2.68/12
-- --- -MIU3.12/9
MIU3.12/11
-- --- -HU3.31/11
-- -LF359,
IUS3.56/9.5,
IUT410
--
16
W
2-1/2
H
12-1/4
D
2-1/2
100%
3310
115%
720
100%
14.72
115%
3.20
100%
2350
115%
511
100%
10.45
115%
2.27
--
16
2-1/2
13-7/16
2-1/2
18
10d
10dx1-1/2
4405
720
19.60
3.20
3128
511
13.91
2.27
--
16
2-1/2
15-1/2
2-1/2
22
10d
10dx1-1/2
4405
720
19.60
3.20
3128
511
13.91
2.27
16
2-1/2
15-1/2
2-1/2
22
10d
10dx1-1/2
4405
720
19.60
3.20
3128
511
13.91
2.27
----x
x
x
x
x
x
18
18
16
16
16
16
12
16
16
12
2-5/8
2-5/8
2-5/8
2-5/8
3-1/8
3-1/8
3-1/8
3-3/8
3-3/8
3-3/8
9-1/16
11-1/16
13-3/8
15-7/16
9-3/16
10-13/16
12-3/4
9-1/16
10-3/4
12-5/8
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
12
14
18
22
12
14
18
12
14
18
10d
10d
10d
10d
10d
10d
10d
10d
10d
10d
2
2
2
2
6
6
6
6
6
6
10dx1-1/2
10dx1-1/2
10dx1-1/2
10dx1-1/2
10d
10d
10d
10d
10d
10d
3310
3310
4405
4405
5180
5420
5420
5180
5420
5420
2300
720
720
720
3325
3325
3325
3325
3325
3325
14.72
14.72
19.60
19.60
23.04
24.11
24.11
23.04
24.11
24.11
10.23
3.20
3.20
3.20
14.79
14.79
14.79
14.79
14.79
14.79
2350
2350
3128
3128
3678
3848
3848
3678
3848
3848
1633
511
511
511
2361
2361
2360
2360
2360
2360
10.45
10.45
13.91
13.91
16.36
17.12
17.12
16.36
17.12
17.12
7.26
2.27
2.27
2.27
10.50
10.50
10.50
10.50
10.50
10.50
--
18
3-1/2
8-5/8
2-1/2
12
10d
10dx1-1/2
5240
465
23.31
2.07
3720
330
16.55
1.47
--
18
3-1/2
11-1/8
2-1/2
16
10d
10dx1-1/2
5240
465
23.31
2.07
3720
330
16.55
1.47
--
16
3-1/2
12-15/16
2-1/2
20
10d
10dx1-1/2
6680
465
29.72
2.07
4743
330
21.10
1.47
Dimensions (in)
Vertical
Uplift1
Vertical
Uplift1
Vertical
Uplift1
Vertical
Uplift1
12
3-5/8
15-3/4
2-1/2
22
10d
10d
6735
3325
29.96
14.79
4782
2360
21.27
10.50
--
16
3-1/2
15
2-1/2
22
10d
10dx1-1/2
6680
465
29.72
2.07
4743
330
21.10
1.47
16
3-1/2
16-9/16
2-1/2
24
10d
10dx1-1/2
6680
2435
29.72
10.83
4743
1729
21.10
7.69
--
16
4-3/16
8-11/16
2-1/2
12
10d
10d
5255
3325
23.38
14.79
3731
2361
16.60
10.50
--
16
4-3/16
11
2-1/2
16
10d
10d
6855
3325
30.49
14.79
4867
2361
21.65
10.50
--
16
4-3/16
13-5/8
2-1/2
20
10d
10d
6735
3325
29.96
14.79
4782
2360
21.27
10.50
THF23925-2
-- --
16
4-3/4
8-3/8
2-1/2
14
10d
10d
5240
3325
23.31
14.79
3720
2361
16.55
10.50
THF23118-2
-- --
16
4-3/4
10-11/16
2-1/2
16
10d
10d
6855
3325
30.49
14.79
4867
2361
21.65
10.50
14.79
4743
2361
21.10
10.50
14.79
4743
2361
21.10
10.50
14.79
14.79
3720
3720
2361
2361
16.55
16.55
10.50
10.50
14.79
4743
2361
21.10
10.50
14.79
4743
2361
21.10
10.50
19.73
19.73
19.73
5123
5123
5123
3149
3149
3149
22.79
22.79
22.79
14.01
14.01
14.01
HU3514-2,
4-1/2 - 4-5/8 x 14 - 22
THF23140-2
x 12 4-3/4
13-5/16 2-1/2 20 10d
6
10d
6680
3325
29.72
MIU4.75/14
HU3516-2,
HU3520-2,
MIU4.75/16,
x 12 4-3/4 15-15/16 2-1/2 24 10d
6
10d
6680
3325
29.72
4-1/2 - 4-5/8 x 16 - 26
THF23160-2
MIU4.75/18,
MIU4.75/20
5 x 9-1/4 - 12
THF25925-2
MIU5.12/9
x 16 5-1/8
8-3/16
2-1/2 12 10d
6
10d
5240
3325
23.31
5 x 11-1/4 - 16
THF25112-2
MIU5.12/11
x 16 5-1/8
10-7/16 2-1/2 16 10d
6
10d
5240
3325
23.31
HU314-2,
5 x 14 - 20
THF25140-2
x 12 5-1/8
13-1/8
2-1/2 20 10d
6
10d
6680
3325
29.72
MIU5.12/14
HU5.125/16,
MIU5.12/16,
x 12 5-1/8
15-3/4
2-1/2 24 10d
6
10d
6680
3325
29.72
5 x 16 - 26
THF25160-2
MIU5.12/18,
MIU5.12/20
7 x 9-1/4 - 14
HD7100
HU410-2
x 14 7-1/8
9
2-1/2 12 16d
6
10d
7215
4435
32.10
7 x 11-1/4 - 16
HD7120
HU412-2
x 14 7-1/8
10-5/8
2-1/2 16 16d
6
10d
7215
4435
32.10
7 x 14 - 20
HD7140
HU414-2
x 14 7-1/8
13-1/8
2-1/2 20 16d
8
10d
7215
4435
32.10
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) NAILS
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
122
1-800-328-5934 www.USPconnectors.com
Joist Size
2-1/2 x 13
USP
StockNo.
THF25130
Fastener Schedule2,3
Header
Joist
continued
EWP Hangers
HD17925IF
HDQ179IF
HUS179
HD17112
1-3/4 x 11-1/4 - 11-7/8
HD17112IF
HDQ17112IF
HUS179
HD1714
1-3/4 x 14
HD1714IF
HDQ1714IF
HUS179
HD1714
1-3/4 x 16
2-11/16 x 9-1/4 - 14
2-11/16 x 11-1/4 - 16
2-11/16 x 14 - 16
HDQ1714IF
HUS179
HD27925
THDH27925
HD27112
THDH27112
HD2714
THDH2714
HD410
3-1/2 x 9-1/4 - 14
HDQ410IF
THD410
THDH410
HD412
3-1/2 x 11-1/4 - 16
HDQ412IF
THD412
THDH412
HD414
3-1/2 x 14 - 20
3-1/2 x 16 - 22
THD414
THDH414
HD416
3-1/2 x 18 - 26
HD418
HD5210
HDQ5210IF
THD610
THDH610
5-1/4 x 11-1/4 - 16
HD5212
HDQ5212IF
THD612
THDH612
5-1/4 x 16 - 22
HD5214
THD614
THDH614
HD5216
6-3/4 x 9-1/4 - 14
THDH6710
5-1/4 x 14 - 20
6-3/4 x 11-1/4 - 18
6-3/4 x 14 - 20-1/2
7 x 9-1/4 - 14
7 x 11-1/4 - 16
7 x 14 - 20
7 x 16 - 22
7 x 18 - 26
THDH6712
THDH6714
HD7100
THD7210
THDH7210
HD7120
THDH7212
HD7140
THDH7214
HD7160
HD7180
HGUS212-4,
HGUS6.88/12
HGUS214-4,
HGUS6.88/14
HU410-2
HHUS7.25/10
HGUS7.25/10
HU412-2
HGUS7.25/12
HU414-2
HGUS7.25/14
-- --- --
Steel Gauge
HD17925
1-3/4 x 9-1/4 - 9-1/2
Ref. No.
HU7
HU9,
MIU1.81/9
-- -HUCQ1.81/9-SDS
HUS1.81/10
HU11,
MIU1.81/11
-- -HUCQ1.81/11-SDS
HUS1.81/10
HU14,
MIU1.81/14,
MIU1.81/16,
MIU1.81/18,
U14
-- --- -HUS1.81/10
HU14,
MIU1.81/14,
MIU1.81/16,
MIU1.81/18,
U14
-- -HUS1.81/10
HU2.75/10
-- -HU2.75/12
-- -HU2.75/14
-- -HU410,
MIU3.56/9
HUCQ410-SDS
HHUS410
HGUS410
HU412,
MIU3.56/11
HUCQ412-SDS
-- -HGUS412
HU414,
MIU3.56/14
-- -HGUS414
HU416,
MIU3.56/16
MIU3.56/18,
MIU3.56/20
HU5.31/9
HUCQ5.25/9-SDS
HHUS5.50/10
HGUS5.25/10,
HGUS5.50/10
HU5.31/11
HUCQ5.25/11-SDS
-- -HGUS5.25/12,
HGUS5.50/12
HU5.31/14
-- -HGUS5.50/14
HU5.31/16
HGUS210-4,
HGUS6.88/10
Factored Resistance
USP
StockNo.
HD1770
14
W
1-13/16
H
7-1/8
D
2
100%
7215
115%
2005
100%
32.10
115%
8.92
100%
5123
115%
1424
100%
22.79
115%
6.33
14 1-13/16
9-1/8
18
16d
10d x 1-1/2
7215
2005
32.10
8.92
5123
1424
22.79
6.33
x
x
14 1-13/16
14 1-13/16
16 1-13/16
9-1/8
9
9-1/8
2
3
3
18
8
30
16d
WS3
16d
6 10d x 1-1/2
4
WS15
10
16d
7215
5315
9025
2005
3025
6035
32.10
23.64
40.15
8.92
13.46
26.85
5123
3775
6408
1424
2150
4285
22.79
16.79
28.50
6.33
9.56
19.06
14 1-13/16
11-3/8
22
16d
10d x 1-1/2
5915
2005
26.31
8.92
4200
1424
18.68
6.33
x
x
14 1-13/16
14 1-13/16
16 1-13/16
11-3/8
11
9-1/8
2
3
3
22
10
30
16d
WS3
16d
6 10d x 1-1/2
6
WS15
10
16d
5915
5470
9025
2005
2975
6035
26.31
24.33
40.15
8.92
13.23
26.85
4200
3885
6408
1424
2110
4285
18.68
17.28
28.50
6.33
9.39
19.06
14 1-13/16
13-5/16
26
16d
10d x 1-1/2
5915
2005
26.31
8.92
4200
1424
18.68
6.33
x
x
14 1-13/16
14 1-13/16
16 1-13/16
13-5/16
13-3/8
9-1/8
2
3
3
26
12
30
16d
WS3
16d
8 10d x 1-1/2
6
WS15
10
16d
5915
5470
9025
2005
2975
6035
26.31
24.33
40.15
8.92
13.23
26.85
4200
3885
6408
1424
2110
4285
18.68
17.28
28.50
6.33
9.39
19.06
14 1-13/16
13-5/16
26
16d
10d x 1-1/2
5915
2005
26.31
8.92
4200
1424
18.68
6.33
x
x
x
x
x
x
x
14
16
14
12
14
12
14
12
1-13/16
1-13/16
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
13-3/8
9-1/8
8-5/8
9-1/8
10-7/8
10-7/8
12-7/8
12-1/4
3
3
2
4
2
4
2
4
12
30
18
46
22
56
26
66
WS3
16d
16d
16d
16d
16d
16d
16d
6
WS15
10
16d
6 10d x 1-1/2
12
16d
6 10d x 1-1/2
14
16d
8 10d x 1-1/2
16
16d
5470
9025
4545
13525
5915
16130
5915
16130
2975
6035
2005
6575
2005
9845
2005
11335
24.33
40.15
20.22
60.16
26.31
71.75
26.31
71.75
13.23
26.85
8.92
29.25
8.92
43.79
8.92
50.42
3885
6408
3225
9605
4200
11450
4200
11450
2110
4285
1425
4670
1425
6990
1425
8050
17.28
28.50
14.35
42.73
18.68
50.93
18.68
50.93
9.39
19.06
6.34
20.77
6.34
31.09
6.34
35.81
14
3-9/16
8-13/16
2-1/2
18
16d
10
10d
7215
4435
32.10
19.73
5123
3149
22.79
14.01
x
x
14
14
12
3-9/16
3-5/8
3-4/7
9
9-1/16
9-1/8
3
3
4
12
38
46
WS3
16d
16d
6
20
12
WS3
10d
16d
8460
11540
14760
4970
7250
7480
37.63
51.33
65.66
22.11
32.25
33.27
6005
8193
10480
3530
5148
5310
26.71
36.45
46.62
15.70
22.90
23.62
14
3-9/16
10-13/16
2-1/2
22
16d
10
10d
7215
4435
32.10
19.73
5123
3149
22.79
14.01
x
x
14
14
12
3-9/16
3-5/8
3-4/7
11
11
10-1/2
3
3
4
14
48
56
WS3
16d
16d
6
20
14
WS3
10d
16d
8460
11540
16130
4970
7250
9845
37.63
51.33
71.75
22.11
32.25
43.79
6005
8193
11450
3530
5148
6989.95
26.71
36.45
50.93
15.70
22.90
31.09
14
3-9/16
12-13/16
2-1/2
24
16d
10
10d
7215
4435
32.10
19.73
5123
3149
22.79
14.01
x
x
14
12
3-5/8
3-4/7
12-7/8
12-1/4
3
4
58
66
16d
16d
20
16
10d
16d
11540
16130
7250
11335
51.33
71.75
32.25
50.42
8193
11450
5148
8050
36.45
50.93
22.90
35.81
14
3-9/16
14-13/16
2-1/2
26
16d
12
10d
7215
4435
32.10
19.73
5123
3149
22.79
14.01
14
3-9/16
16-1/2
2-1/2
28
16d
10d
7215
2685
32.10
11.94
5123
1906
22.79
8.48
x
x
14
14
12
5-3/8
5-1/4
5-1/2
7-7/8
9
9
2-1/2
3
3
18
12
38
16d
WS3
16d
10
6
20
10d
WS3
10d
7215
8460
12455
4435
4970
6425
32.10
37.63
55.40
19.73
22.11
28.58
5123
6005
8843
3149
3530
4562
22.79
26.71
39.34
14.01
15.70
20.29
12
5-1/2
46
16d
16
16d
13190
7030
58.67
31.27
9365
4990
41.66
22.20
x
x
14
14
12
5-3/8
5-1/4
5-1/2
9-7/8
11
11
2-1/2
3
3
22
14
48
16d
WS3
16d
10
6
20
10d
WS3
10d
7215
8460
13785
4435
4970
9850
32.10
37.63
61.32
19.73
22.11
43.82
5123
6005
9787
3149
3530
6994
22.79
26.71
43.54
14.01
15.70
31.11
12
5-1/2
11
56
16d
20
16d
15465
9105
68.79
40.50
10980
6465
48.84
28.76
x
x
x
14
12
12
14
5-3/8
5-1/2
5-1/2
5-3/8
11-7/8
12-7/8
13
13-7/8
2-1/2
3
4
2-1/2
24
58
66
30
16d
16d
16d
16d
10
20
22
12
10d
10d
16d
10d
7215
13785
18810
7215
4435
9850
10760
4435
32.10
61.32
83.67
32.10
19.73
43.82
47.86
19.73
5123
9787
13355
5123
3149
6994
7640
3149
22.79
43.54
59.41
22.79
14.01
31.11
33.99
14.01
12
6-7/8
8-13/16
46
16d
12
16d
13525
6575
60.16
29.25
9605
4670
42.73
20.77
12
6-7/8
10-13/16
56
16d
14
16d
16130
9845
71.75
43.79
11450
6990
50.93
31.09
12
6-7/8
12-13/16
66
16d
16
16d
16130
11335
71.75
50.42
11450
8050
50.93
35.81
x
x
x
x
x
x
x
x
x
14
12
12
14
12
14
12
14
14
7-1/8
7-1/4
7-1/4
7-1/8
7-1/4
7-1/8
7-1/4
7-1/8
7-1/8
9
9
9
10-5/8
10-1/2
13-1/8
12-1/4
15-5/8
17-3/4
2-1/2
3
4
2-1/2
4
2-1/2
4
2-1/2
2-1/2
12
38
46
16
56
20
66
24
28
16d
16d
16d
16d
16d
16d
16d
16d
16d
6
20
12
6
14
8
16
8
8
10d
10d
16d
10d
16d
10d
16d
10d
10d
7215
12455
14760
7215
16130
7215
16130
7215
7215
4435
6425
7480
4435
9845
4435
11335
4435
4435
32.10
55.40
65.66
32.10
71.75
32.10
71.75
32.10
32.10
19.73
28.58
33.27
19.73
43.79
19.73
50.42
19.73
19.73
5123
8843
10480
5123
11450
5123
11450
5123
5123
3149
4562
5310
3149
6990
3149
8050
3149
3149
22.79
39.34
46.62
22.79
50.93
22.79
50.93
22.79
22.79
14.01
20.29
23.62
14.01
31.09
14.01
35.81
14.01
14.01
Header
Joist
Vertical
Uplift1
Vertical
Uplift1
Vertical
Uplift1
Vertical
Uplift1
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) Minimum nail embedment shall be 8 nail diameters (typ).
!!#'$#)( )
!!#'$#)(
) # &'% #$
4) NAILS( ) $#)( )! $#)(
)!
$#
)(
)!
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
'"#!&%$!#&"%"#!&% !#%! #$ % red font.
1-800-328-5934 www.USPconnectors.com
USP2240-131
EWP Hangers
Joist Size
1-3/4 x 7-1/4
Fastener Schedule2,3,4
Dimensions (in)
123
EWP Hangers
Typical TFL
installation
2
1 1/2
Installation:
Use all specified fasteners. See Product Notes, page 10.
Refer to the top mount chart for applications requiring web stiffeners.
Requirements for web stiffener from the I-Joist manufacturer should be followed,
even if web stiffeners are not required in USP literature.
For BPH welded installation, see page 213.
TFL
TFI
Typical BPH
installation
Typical THO
installation
TF
Slant Nailing
via dimple
nail holes
TF
H
H
Diamond
holes
BPH
124
THO
BPH These hangers are used to support LVL, LSL,and PSL beams and
headers in light-to-medium load conditions.
Top Mount Hangers BPH, TFI, TFL, & THO series continued
Fastener Schedule
Header
USP
Series
TFL
THO
THO (Double)
THO (Double)
TFI
BPH
EWP Hangers
Joist
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
Nailer
Size
Qty
Type
Qty
Type
100%
115%
100%
115%
100%
115%
100%
115%
2X
3X
(2) 2X
4X
2X
3X
(2) 2X
4X
2X
3X
(2) 2X
4X
2X
3X
(2) 2X
4X
4X
4X
2X
3X
(2) 2X
4X
6
6
6
6
6
6
6
6
6
6
10
10
6
6
10
10
6
10
6
8
8
8
10d x 1-1/2
16d x 2-1/2
10d
16d
10d x 1-1/2
16d x 2-1/2
10d
16d
10d x 1-1/2
16d x 2-1/2
10d
16d
10d x 1-1/2
16d x 2-1/2
10d
16d
16d
16d
10d x 1-1/2
16d x 2-1/2
10d
16d
2
2
2
2
2
2
2
2
6
6
6
6
6
6
6
6
2
2
4
4
4
4
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d
10d
10d
10d
10d
10d
10d
10d
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
1830
2305
1845
2535
1960
2115
1965
2210
2095
3360
3415
3840
2095
3360
3415
3840
3685
4675
2995
3400
3325
3235
265
265
265
265
375
375
375
375
375
520
520
520
375
520
520
520
375
375
240
555
555
555
8.14
10.25
8.21
11.28
8.72
9.41
8.74
9.83
9.32
14.95
15.19
17.08
9.32
14.95
15.19
17.08
16.39
20.80
13.32
15.12
14.79
14.39
1.18
1.18
1.18
1.18
1.67
1.67
1.67
1.67
1.67
2.31
2.31
2.31
1.67
2.31
2.31
2.31
1.67
1.67
1.07
2.47
2.47
2.47
1575
1980
1585
2180
1685
1820
1690
1900
1800
2890
2935
3300
1800
2890
2935
3300
3170
4020
2575
2925
2860
2780
230
230
230
230
325
325
325
325
325
445
445
445
325
445
445
445
325
325
205
475
475
475
7.01
8.81
7.05
9.70
7.50
8.10
7.52
8.45
8.01
12.86
13.06
14.68
8.01
12.86
13.06
14.68
14.10
17.88
11.45
13.01
12.72
12.37
1.02
1.02
1.02
1.02
1.45
1.45
1.45
1.45
1.45
1.98
1.98
1.98
1.45
1.98
1.98
1.98
1.45
1.45
0.91
2.11
2.11
2.11
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake;
reduce for other load durations in accordance with the code.
2) Listed loads shall not be increased.
3) Minimum nail embedment shall be 8 nail diameters (typ).
4) NAILS:
Skewed1,3
5.)
5
Sloped Seat2,3
5.)
5
Sloped / Skewed1,2,3
&)*.(%1
Factored
Resistance
) .&0&/
) .&0&/
) .&0&/
/.&0&/-/-#(!
-.,#!".&#(#(.,*)&.#)(
Ordering
SK, (!&,+/#,
(,#!".(R) ),& .(L),
.)*,)/.(/',
2
SL, &)*,+/#,
(/*(U) ),)1((D),
.)*,)/.(/',
2
&)*.(%1
2
SF, (!&,+/#,
(,#!".(R) ),& .(L),
.)*,)/.(/',
2
1-800-328-5934 www.USPconnectors.com
USP2240-131
125
EWP Hangers
USP Nailer
Series Size
4X
HLBH
4X
Joist
L
4 3/8
TF
Factored Resistance
Fastener Schedule
Header
Typical HLBH
installation
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
1
1
1
1
Vertical Uplift Vertical Uplift Vertical Uplift Vertical Uplift
Qty
Type
Qty
Type
100% 115% 100% 115% 100% 115% 100% 115%
6.36 12840 1235 57.12
15 NA16D-RS 6 10d x 1-1/2 13825 1430 61.50
5.49
7.87 12840 1430 57.12
15 NA16D-RS 6
16d
13825 1770 61.50
6.36
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake;
reduce for other load durations in accordance with the code.
2) Listed loads shall not be increased.
3) NAILS% &!
&% &!
% ! &%
&
$ #"! #" #" " !" red font.
HLBH
Specialty Options Chart refer to Specialty Options pages 210 and 212 for additional details.
Option
Range
Skewed1,3
<50 <
Sloped Seat2,3
<50 <
Sloped / Skewed1,2,3
&& -01&% &"5"/% ,&8&%
Factored
Resistance
-#4"9
0'61-*'5-0"%0/
4,&8(3&"5&35)"/
<
-#4"9
-#4"9
0'61-*'5-0"%0/
4,&8(3&"5&35)"/
<
Ordering
%%SK, "/(-&3&26*3&%
"/%3*()5(R) 03-&'5(L),
50130%6$5/6.#&3
9
%%SL, 4-01&3&26*3&%
"/%61(U) 03%08/(D),
50130%6$5/6.#&3
9
0'5"#-&-0"%
%%S, "/%
3*()5(R) 03-&'5(L),
50130%6$5/6.#&3
9
Saddle5
Ridge
<50
<
0'5"#-&-0"%
1&34*%&
See footnote 5.
0'5"#-&-0"%
%%SA, "/%4"%%-&
8*%5)3&26*3&%
50130%6$5/6.#&3
9
=
%%DA, "/%
"/(-&3&26*3&%
50130%6$5/6.#&3
9
,&8&%)"/(&348*5)4,&84(3&"5&35)"/
;.":)"7&"--+0*45/"*-*/(0/0654*%&'-"/(&
-01&%034-01&%4,&8&%)"/(&348*5)4-01&4(3&"5&35)"/
;.":)"7&"%%*5*0/"-+0*45/"*-4
--4-01&%4,&8&%03$0.#*/"5*0/43&26*3&#&7&-$650/+0*45*/"--"11-*$"5*0/4"/%8-*''&/&348*5)+0*454
-01&%501'-"/(&48*5)4-01&4(3&"5&35)"/
;.":)"7&"%%*5*0/"-)&"%&3/"*-4
*/*.6.)&"%&35)*$,/&444)"--#&%06#-&5)&501'-"/(&!%*.&/4*0/'03
5"#-&-0"%
MPH Designed to work with standard 6 or larger grouted concrete block wall construction. Eliminates
the need for masons to fabricate special seats to support I-Joists or composite wood beams.
PHM & PHXU Used to connect LVL, LSL,and PSLbeams to headers in medium load conditions
using standard nails.
Materials:
Finish:
Options:
Codes:
Installation:
Use all specified fasteners. See Product Notes, page 10.
For MPH series: 16d duplex nails are not provided. Place hanger on top of concrete block. Install
(2) 16d duplex nails (8 gauge or 0.162 dia. x 312 double head) in the grouted cavity, and then
continue laying the next course of block. Larger holes on top flange are provided to aid grout flow. A
minimum of one course must be laid over hanger top flange and one course below hanger top
flange. Courses adjacent to the top flange shall be subsequently grouted.
For PHM & PHXU welded installations, see page 213.
126
1-800-328-5934 www.USPconnectors.com
Typical MPH
installation
3 3/4
TF
PHM
2 1/2
EWP Hangers
TF
Typical PHXU
installation
PHXU
MPH
PHM & PHXU Nailer Options chart represents maximum factored resistance
for hangers used on wood nailers. Reference page 117.
Factored Resistance2
Fastener Schedule3
Header
USP
Series
PHM
PHXU
-+('
PHXU
-
Nailer
Size
2X
3X
(2) 2X
4X
Joist
DF-L (Lbs)
Qty
Type
Qty
Type
2 10d x 1-1/2 2 10d x 1-1/2
2 16d x 2-1/2 2 10d x 1-1/2
2
10d
2 10d x 1-1/2
2
16d
2 10d x 1-1/2
DF-L (kN)
1
S-P-F (Lbs)
1
S-P-F (kN)
1
Vertical
100%
4335
5140
4790
4685
Uplift
115%
-- --- --- --- --
Vertical
100%
19.28
22.86
21.31
20.84
Uplift
115%
-- --- --- --- --
Vertical
100%
3730
4420
4120
4030
Uplift
115%
-- --- --- --- --
Vertical
100%
16.59
19.66
18.33
17.93
Uplift
115%
-- --- --- --- --
4X
16d
10d x 1-1/2
6370
1210
28.34
5.38
4420
920
19.66
4.09
4X
4X
8
8
16d
16d
6
6
10d x 1-1/2
10d
7610
7610
1005
1290
33.85
33.85
4.47
5.74
5170
5170
865
1150
23.00
23.00
3.85
5.12
Specialty Options Chart refer to Specialty Options pages 210 and 212 for additional details.
Option
USP Series
Skewed1,3,5
?83 ?
Range
PHM
PHXU
MPH
?83 ?
Sloped Seat2,3
Sloped / Skewed1,2,3
?83 ?
!))!034)(!)%8
%2(!/);)(
>83>
PHM
Factored
Resistance
PHXU
3*8%&0)03%(
3*8%&0)03%(
MPH
PHM
Ordering
PHXU
MPH
((SK,
%2+0)6)59-6)(%2(
6-+,8(R) 360)*8(L),
83463(9'8291&)6
<$#
!
((SL,
7034)6)59-6)(%2(
94(U) 36(3;2(D),
83463(9'8291&)6
<$#
!
3*8%&0)03%(9483
%<03%(3* 0&7
3*8%&0)03%(9483
%<03%(3* 0&7
3*8%&0)03%(
)(9')
%003;%&0)8%&0)
03%(797-2+
786%-+,80-2)
-28)6430%8-32
!))!034)(!)%8
%2(!/);)(
<
$#
!
!
((SF,
%2+0)6)59-6)(%2(
6-+,8(R) 360)*8(L),
83463(9'8291&)6
<$#
!
Saddle5,6
N/A
@83
@
((OS, and
6-+,8(R) 360)*8(L),
83463(9'8291&)6
<$#
!
3*8%&0)03%(
See footnote 6.
((SA,
%2(7%((0)
;-(8,6)59-6)(
83463(9'8291&)6
<$#
!
@
N/A
Ridge
?83
?
N/A
N/A
3*8%&0)03%(
((DA, and
%2+0)6)59-6)(83
83463(9'8291&)6
<$#
N/A
N/A
!/);)(,%2+)67;-8,7/);7+6)%8)68,%2
>1%=,%:)%00.3-782%-0-2+323987-()*0%2+)
!034)(367034)(7/);)(,%2+)67;-8,7034)7+6)%8)68,%2
>1%=,%:)%((-8-32%0.3-782%-07
007034)(7/);)(36'31&-2%8-3276)59-6)&):)0'9832.3-78-2%00%440-'%8-327%2(;)&78-**)2)67;-8,.3-787
!034)(834*0%2+)7;-8,7034)7+6)%8)68,%2
>1%=,%:)%((-8-32%0,)%()62%-07
!/);)(834*0%2+)3**7)8367%((0)348-327;-00,%:)%730-(;)0()(834*0%2+)
-2-191,)%()68,-'/2)777,%00&)(39&0)8,)834*0%2+)"(-1)27-32*36
8%&0)03%(
7) PHXU offset option - hanger will be welded with a closed top angle, not formed.
);463(9'873694(%8)(463(9'8-2*361%8-32%6)()7-+2%8)(-2 red font.
1-800-328-5934 www.USPconnectors.com
USP2240-131
127
Qty
Type
Qty
Type
9-1/4
--
1-1/2
10d
10d x 1-1/2
BPH15925
LBV1.56/9.25
12
1-9/16
9-1/4
2-3/8
--
1-1/2
10
16d
10d x 1-1/2
MPH210
WM29.25
--
12
1-9/16
9-1/4
2-1/2
3-3/4
16d duplex
10d x 1-1/2
THO15950
LT159
--
18
1-1/2
9-1/2
--
1-1/2
10d
10d x 1-1/2
BPH1595
LBV1.56/9.5,
MIT29.5
12
1-9/16
9-1/2
2-3/8
--
1-1/2
10
16d
10d x 1-1/2
MPH1595
WM29.5
--
12
1-9/16
9-1/2
2-1/2
3-3/4
16d duplex
10d x 1-1/2
BPH15112
LBV1.56/11.25
12
1-9/16
11-1/4
2-3/8
--
1-1/2
10
16d
10d x 1-1/2
MPH212
WM211.25
--
12
1-9/16
11-1/4
2-1/2
3-3/4
16d duplex
10d x 1-1/2
THO15118
LT151188,
MIT211.88
--
18
1-1/2
11-7/8
--
1-9/16
10d
10d x 1-1/2
BPH15118
LBV1.56/11.88
12
1-9/16
11-7/8
2-3/8
--
1-1/2
10
16d
10d x 1-1/2
MPH15118
WM211.88
--
12
1-9/16
11-7/8
2-1/2
3-3/4
16d duplex
10d x 1-1/2
--
16
1-9/16
14
2-3/8
--
1-1/2
10
10d
10d x 1-1/2
12
1-9/16
14
2-3/8
--
1-1/2
10
16d
10d x 1-1/2
1-1/2 x 11-7/8
-- --
THO15140
1-1/2 x 14
BPH1514
LBV1.56/14
MPH1514
-- --
--
12
1-9/16
14
2-1/2
3-3/4
16d duplex
10d x 1-1/2
1-5/8 x 9-1/2
THO16950
-- --
--
18
1-11/16
9-1/2
--
1-1/2
10d
10d x 1-1/2
1-5/8 x 11-1/4
THO16112
-- --
--
16
1-11/16
11-1/4
--
1-1/2
10d
10d x 1-1/2
1-5/8 x 11-7/8
THO16118
-- --
--
16
1-11/16
11-7/8
--
1-1/2
10d
10d x 1-1/2
1-5/8 x 14
THO16140
-- --
--
16
1-11/16
14
--
1-3/4
10
10d
10d x 1-1/2
1-3/4 x 7-1/4
PHXU17725
LBV1.81/7.25,
WP1.81/7.25
1-13/16
7-1/4
3-1/4
10
2-1/2
16d
10d x 1-1/2
1-3/4 x 9-1/4
BPH17925
LBV1.81/9.25
1-13/16
9-1/4
2-3/8
--
1-11/16
10
16d
PHM17925
WP9.25
x 7/10 1-13/16
9-1/4
2-1/2
16d
1-13/16
9-1/4
3-1/4
10
2-1/2
16d
PHXU17925 WPU1.81/9.25
1-3/4 x 9-1/2
12
THO17950
LT179,
ITS1.81/9.5
--
18
1-3/4
9-1/2
--
1-1/2
10d
BPH1795
LBV1.81/9.5,
MIT9.5
12
1-13/16
9-1/2
2-3/8
--
1-11/16
10
16d
PHM1795
WP9
x 7/10 1-13/16
9-1/2
2-1/2
16d
PHXU1795
MPH1795
-- -WM9
1-13/16
9-1/2
3-1/4
10
2-1/2
16d
--
12
1-13/16
9-1/2
2-1/2
3-3/4
16d duplex
DF-L
I-Joist2
1860
8.27
4415
19.64
--1860
8.27
4415
19.64
--4415
19.64
---
1920
8.54
4415
19.64
--1920
8.54
4415
19.64
--4415
19.64
---
1645 1170
-7.32 5.20
-3780 2865
-16.81 12.74
---3745
--16.66
1790 1270
-7.96 5.65
-3780 2865
-16.81 12.74
---3745
--16.66
3780 2865
-16.81 12.74
---3745
--16.66
Lbs
1880
1935
1860
1920
1975
1405
--
505
kN
8.36
8.61
8.27
8.54
8.79
6.25
--
2.25
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
-4415
-19.64
----1485 1485
6.61 6.61
-4415
-19.64
----1445 1935
6.43 8.61
1485 1935
6.61 8.61
1485 1935
6.61 8.61
1485 1485
6.61 6.61
4415
19.64
--1485
6.61
4415
19.64
--1860
8.27
1860
8.27
1860
8.27
1485
6.61
4415
19.64
--1485
6.61
4415
19.64
--1920
8.54
1920
8.54
1920
8.54
1485
6.61
3780 2865
-16.81 12.74
---3745
--16.66
1690 1200
-7.52 5.34
-3780 2865
-16.81 12.74
---3745
--16.66
1645 1170
-7.32 5.20
-1690 1200
-7.52 5.34
-1690 1200
-7.52 5.34
-1690 1200
-7.52 5.34
--
780
3.47
--435
1.94
780
3.47
--435
1.94
435
1.94
435
1.94
435
1.94
LVL
Unit
Lbs 1445 1935
kN 6.43 8.61
Lbs
-4415
kN
-19.64
Lbs
--kN
--Lbs 1815 1935
kN 8.07 8.61
Lbs
-4415
kN
-19.64
Lbs
--kN
--Lbs
-4415
kN
-19.64
Lbs
--kN
---
LSL
1-1/2 x 11-1/4
435
1.94
780
3.47
--505
2.25
780
3.47
--780
3.47
---
Lbs
--
6370
6370
6370
6370
4420
--
1210
kN
--
28.34
28.34
28.34
28.34 19.66
--
5.38
Lbs
10d x 1-1/2
kN
Lbs
10d x 1-1/2
kN
Lbs
10d x 1-1/2
kN
-------
4890
21.75
5090
22.64
6370
28.34
4890
21.75
4795
21.33
6370
28.34
4890
21.75
4435
19.73
6370
28.34
4320 3235
19.22 14.39
4125 4125
18.35 18.35
6370 4420
28.34 19.66
-------
780
3.47
--1210
5.38
Lbs
1570
1935
1860
1920
2195
1560
--
505
kN
6.98
8.61
8.27
8.54
9.76
6.94
--
2.25
---------
4890
21.75
5090
22.64
6370
28.34
---
4890
21.75
4795
21.33
6370
28.34
---
4890
21.75
4435
19.73
6370
28.34
---
4320 3235
-780
19.22 14.39
-3.47
4125 4125
--18.35 18.35
--6370 4420
-1210
28.34 19.66
-5.38
--4305
---19.15
--
10d x 1-1/2
Lbs
kN
Lbs
10d x 1-1/2
kN
Lbs
10d x 1-1/2
kN
Lbs
10d x 1-1/2
kN
10d x 1-1/2
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) When I-joist is used as a header, all nails must be 10d x 1-1/2.
3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.
4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
5) Minimum nail embedment shall be 8 nail diameters (typ.).
6) NAILS
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
L
TF
H
W
128
DF-L 115%
TF
1-9/16
Masonry3
18
Uplift1
SPF
--
Ref. No.
DF-L
LT15925
Joist
1-1/2 x 9-1/2
THO15925
USP
Stock No.
Header
PSL
1-1/2 x 9-1/4
Joist Size
Factored Resistance4
Header Material (100%)
Fastener Schedule2,5,6
Dimensions (in)
Steel Gauge
EWP Hangers
PHXU17112 WPU1.81/11.25
1-3/4 x 11-7/8
Type
12
1-13/16
11-1/4
2-3/8
--
1-11/16
10
16d
10d x 1-1/2
x 7/10 1-13/16
11-1/4
2-1/2
16d
10d x 1-1/2
1-13/16
11-1/4
3-1/4
10
2-1/2
16d
BPH17118
BA1.81/11.88,
LBV1.81/11.88
1-13/16
11-7/8
2-3/8
--
1-11/16
10
16d
PHM17118
WP11
x 7/10 1-13/16
11-7/8
2-1/2
16d
--
x
--
18
12
7
12
1-3/4
1-13/16
1-13/16
11-7/8
11-7/8
11-7/8
3-1/4
2-1/2
--
10
7
1-9/16
2-1/2
3-3/4
8
2
10d
16d
16d duplex
10d x 1-1/2
10d x 1-1/2
2-1/2
16d
PHXU1714
WPU1.81/14
1-13/16
14
3-1/4
10
2-1/2
16d
10d x 1-1/2
MPH1714
WM14
--
12
1-13/16
14
2-1/2
3-3/4
16d duplex
10d x 1-1/2
TFL1716
LT1716,
ITS1.81/16
BPH1716
B1.81/16,
LBV1.81/16,
MIT1.81/16
1-13/16
16
2-3/8
--
1-11/16
10
16d
10d x 1-1/2
PHM1716
WP16
x 7/10 1-13/16
16
2-1/2
16d
10d x 1-1/2
MPH1716
WM16
--
16
2-1/2
3-3/4
16d duplex
10d x 1-1/2
TFL2095
LT209,
ITS2.06/9.5
2 - 2-1/8
TFL20118
x 11-7/8
LT2011.88,
ITS2.06/11.88
--
--
12
12
18
18
1-13/16
2-1/8
2-1/8
9-1/2
11-7/8
--
--
1-1/2
1-1/2
10d
10d
10d
kN
--
5.38
--
505
kN
7.72
10d x 1-1/2
14
--
Lbs
--
x 7/10 1-13/16
1-1/2
1210
1210
WP14
--
--
--
PHM1714
--
16
--
16d
1-3/4
--
Lbs
10
18
--
--
--
1-11/16
--
--
--
--
--
Lbs
2-3/8
10d
--
kN
780
3.47
--
14
Lbs
2.25
1-13/16
12
1-1/2
3.47
--
--
780
--
----
BPH1714
--
6.92
LBV1.81/14,
MIT1.81/14
14
--
TFL1714
1-3/4
--
kN
----
LT1714,
ITS1.81/14
18
Lbs
Lbs
10d x 1-1/2
kN
Lbs
10d x 1-1/2
kN
WM11
--
Unit
10d x 1-1/2
MPH17118
DF-L 115%
Qty
Masonry3
Type
Uplift1
SPF
Qty
THO17118
1-3/4 x 16
2 - 2-1/8
x 9-1/2
TF
LT171188,
ITS1.81/11.88,
MIT11.88
PHXU17118 WPU1.81/11.88
1-3/4 x 14
DF-L
-- --
LSL
PHM17112
Joist
LVL
LBV1.81/11.25
Header
DF-L
I-Joist2
BPH17112
Ref. No.
Steel Gauge
1-3/4 x 11-1/4
USP
Stock No.
Factored Resistance4
Header Material (100%)
Fastener Schedule2,5,6
Dimensions (in)
EWP Hangers
Joist Size
continued
PSL
10d x 1-1/2
8.61
8.27
8.54
9.76
kN
--
--
5.38
Lbs
--
--
--
--
--
--
4305
--
kN
--
--
--
--
--
--
19.15
--
--
265
Lbs
kN
--
1.18
Lbs
10d x 1-1/2
kN
Lbs
10d x 1-1/2
kN
----
----
780
3.47
--
--
--
--
Lbs
--
--
1210
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
kN
--
--
5.38
Lbs
--
--
--
--
--
--
4305
--
kN
--
--
--
--
--
--
19.15
--
Lbs
--
265
kN
--
1.18
Lbs
--
--
780
kN
--
--
3.47
Lbs
--
--
--
kN
--
--
--
Lbs
--
--
--
--
--
--
4305
--
kN
--
--
--
--
--
--
19.15
--
--
265
1.18
Lbs
kN
--
Lbs
--
265
kN
--
1.18
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) When I-joist is used as a header, all nails must be 10d x 1-1/2.
3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.
4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
5) Minimum nail embedment shall be 8 nail diameters (typ.).
6) NAILS
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
L
TF
H
W
USP2240-131
129
TF
Qty
Type
Qty
Type
--
18
2-1/8
14
--
1-1/2
10d
10d x 1-1/2
TFL2016
LT2016
--
18
2-1/8
16
--
1-1/2
10d
10d x 1-1/2
TFL2395
LT239,
ITS2.37/9.5
--
18
2-5/16
9-1/2
--
1-1/2
10d
10d x 1-1/2
--
12
2-3/8
9-1/2
2-1/2
3-3/4
16d duplex
10d x 1-1/2
2-1/4 - 2-5/16
x 9-1/2
MPH2395
2-1/4 - 2-5/16
x 11-7/8
2-1/4 - 2-5/16
x 14
2-1/4 - 2-5/16
x 16
TFL23118
LT231188,
ITS2.37/11.88
--
18
2-5/16
11-7/8
--
1-1/2
10d
10d x 1-1/2
MPH23118
WM3511.88
--
12
2-3/8
11-7/8
2-1/2
3-3/4
16d duplex
10d x 1-1/2
TFL2314
LT2314,
ITS2.37/14
--
18
2-5/16
14
--
1-1/2
10d
10d x 1-1/2
THO23140
LBV2.37/14
--
18
2-3/8
14
2-3/8
--
12
10d
10d x 1-1/2
TFI3514
MIT3514
--
16
2-3/8
14
2-1/2
--
2-1/16
16d
10d x 1-1/2
PHM2314
WP3514
x 7/10
2-3/8
14
2-1/2
16d
10d x 1-1/2
MPH2314
-- --
--
12
2-3/8
14
2-1/2
3-3/4
16d duplex
10d x 1-1/2
TFL2316
-- --
--
18
2-5/16
16
--
1-1/2
10d
10d x 1-1/2
16
2-3/8
16
2-1/2
--
2-1/16
16d
10d x 1-1/2
TFI3516
MIT3516
--
PHM2316
WP3516
x 7/10
2-3/8
16
2-1/2
16d
10d x 1-1/2
MPH2316
2-1/4 - 2-5/16
x 18
-- --
--
12
2-3/8
16
2-1/2
3-3/4
16d duplex
10d x 1-1/2
TFI3518
HIT3518,
LBV2.37/18,
MIT3518
--
16
2-3/8
18
2-1/2
--
2-1/16
16d
10d x 1-1/2
PHM2318
WP3518
x 7/10
2-3/8
18
2-1/2
16d
10d x 1-1/2
Lbs
1795
2370
2305
2450
2495
1771
--
265
kN
7.98
10.54
10.25
10.90
11.10
7.88
--
Lbs
1795
2370
2305
2450
2495
1771
--
265
kN
7.98
10.54
10.25
10.90
11.10
7.88
--
1.18
Lbs
--
--
--
--
--
--
5565
--
kN
--
--
--
--
--
--
24.76
--
Lbs
1795
2370
2305
2450
2495
1771
--
265
kN
7.98
10.54
10.25
10.90
11.10
7.88
--
1.18
Lbs
kN
---
---
---
---
---
---
5565
24.76
---
Lbs
1795
2370
2305
2450
2495
1771
--
265
kN
7.98
10.54
10.25
10.90
11.10
7.88
--
1.18
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
3865
17.19
------1795
7.98
-------
3865
17.19
3685
16.39
5140
22.86
--2370
10.54
3685
16.39
5140
22.86
---
3865
17.19
3220
14.32
5140
22.86
--2305
10.25
3220
14.32
5140
22.86
---
3865
17.19
3260
14.50
4435
19.73
--2450
10.90
3260
14.50
4435
19.73
---
4450
19.80
4190
18.64
4125
18.35
--2495
11.10
4190
18.64
4125
18.35
---
3160
14.06
2975
13.23
4125
18.35
--1771
7.88
2975
13.23
4125
18.35
---
------5565
24.76
------5565
24.76
500
2.22
545
2.42
----265
1.18
545
2.42
-----
4190
2975
--
545
18.64
13.23
--
2.42
Lbs
kN
Lbs
10d x 1-1/2
kN
-----
5140
22.86
---
5140
22.86
---
4435
19.73
---
4125
18.35
---
4125
18.35
---
--5565
24.76
-----
16d duplex
TFI3520
--
16
2-3/8
20
2-1/2
--
2-1/16
16d
10d x 1-1/2
PHM2320
WP3520
x 7/10
2-3/8
20
2-1/2
16d
10d x 1-1/2
12
2-3/8
20
2-1/2
3-3/4
16d duplex
10d x 1-1/2
--
18
2-1/2
9-1/4
--
1-1/2
10d
10d x 1-1/2
-- --
--
12
2-1/2
9-1/4
2-1/2
3-3/4
16d duplex
10d x 1-1/2
TFL25938
LT259375
--
18
2-1/2
9-3/8
--
1-1/2
10d
10d x 1-1/2
TFL2595
LT259,
ITS2.56/9.5
--
18
2-1/2
9-1/2
--
1-1/2
10d
10d x 1-1/2
--
12
2-1/2
9-1/2
2-1/2
3-3/4
16d duplex
10d x 1-1/2
-- --
1.18
3260
MPH2595
265
--
14.50
3-3/4
2-1/2 x 9-1/2
--
7.88
3220
2-1/2 x 9-1/4
2-1/2 x 9-3/8
1771
11.10
14.32
MPH25925
2495
10.90
3685
2-1/2
LT25925
2450
10.25
16.39
18
TFL25925
2305
10.54
--
2-3/8
-- --
2370
7.98
--
12
MPH2320
1795
kN
kN
-- --
Lbs
Lbs
HIT3520,
LBV2.37/20,
MIT3520
MPH2318
2-1/4 - 2-5/16
x 20
-- --
SPF
2 - 2-1/8 x 16
DF-L
TFL2014
Unit
Lbs
--
3685
3220
3260
4190
2975
--
545
kN
--
16.39
14.32
14.50
18.64
13.23
--
2.42
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
----1795
7.98
--1795
7.98
1795
5140
22.86
--2370
10.54
--2370
10.54
2370
5140
22.86
--2305
10.25
--2305
10.25
2305
4435
19.73
--2450
10.90
--2450
10.90
2450
4125
18.35
--2495
11.10
--2495
11.10
2495
4125
18.35
--1771
7.88
--1771
7.88
1771
--5565
24.76
--5990
26.65
----
----265
1.18
--265
1.18
265
kN
Lbs
kN
7.98
---
10.54
---
10.25
---
10.90
---
11.10
---
7.88
---
-5990
26.65
1.18
---
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) When I-joist is used as a header, all nails must be 10d x 1-1/2.
3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.
4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
5) Minimum nail embedment shall be 8 nail diameters (typ.).
6) NAILS
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
New products or updated product information are designated in red font.
L
TF
H
W
130
2 - 2-1/8 x 14
DF-L 115%
Uplift1
Masonry3
LSL
LT214,
ITS2.06/14
PSL
Joist
LVL
Ref. No.
Header
DF-L
I-Joist2
USP
Stock No.
Factored Resistance4
Header Material (100%)
Fastener Schedule2,5,6
Dimensions (in)
Joist Size
continued
Steel Gauge
EWP Hangers
LT251125
--
18
2-1/2
11-1/4
--
1-1/2
10d
10d x 1-1/2
-- --
--
12
2-1/2
11-1/4
2-1/2
3-3/4
16d duplex
10d x 1-1/2
Qty
Type
Qty
Type
2-1/2 x 11-1/4
MPH25112
TFL25118
2-1/2 x 11-7/8
2-1/2 x 13
--
18
2-1/2
11-7/8
--
1-1/2
10d
10d x 1-1/2
THO25118
MIT311.88
--
16
2-9/16
11-7/8
2-3/8
--
1-15/16
10
10d
10d x 1-1/2
MPH25118
-- --
--
12
2-1/2
11-7/8
2-1/2
3-3/4
16d duplex
10d x 1-1/2
--
18
2-1/2
13
--
1-1/2
10d
10d x 1-1/2
TFL2513
TFL2514
THO25140
2-1/2 x 14
ITS2.56/11.88
LT2513
ITS2.56/14
--
18
2-1/2
14
--
1-1/2
10d
10d x 1-1/2
-- --
--
18
2-9/16
14
2-3/8
--
12
10d
10d x 1-1/2
16
2-9/16
14
2-1/2
--
16d
10d x 1-1/2
TFI314
MIT314
--
PHM2514
WPI314
-- 7/10
2-9/16
14
2-1/2
16d
10d x 1-1/2
--
12
2-1/2
14
2-1/2
3-3/4
16d duplex
10d x 1-1/2
--
18
2-1/2
16
--
1-1/2
10d
10d x 1-1/2
--
16
2-9/16
16
2-1/2
--
16d
10d x 1-1/2
2-9/16
16
2-1/2
16d
10d x 1-1/2
MPH2514
TFL2516
TFI316
2-1/2 x 16
PHM2516
MPH2516
TFI318
2-1/2 x 18
MPH2518
TFI320
2-1/2 x 20
MPH2520
TFI322
2-1/2 x 22
MPH2522
-- -LT2516
MIT316
WPI316
-- -
MIT318
-- -
MIT320
-- -
WPI322
-- --
-- 7/10
--x
-x
12
16
12
16
12
2-1/2
2-9/16
2-1/2
2-9/16
2-1/2
16
18
18
20
20
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
7
-7
-7
3-3/4
2
3-3/4
2
3-3/4
2
6
2
6
2
16d duplex
16d
16d duplex
16d
16d duplex
2
2
2
2
2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
--
16
2-9/16
22
2-1/2
--
10
16d
10d x 1-1/2
12
2-1/2
22
2-1/2
3-3/4
16d duplex
10d x 1-1/2
Unit
Masonry3
TF
SPF
DF-L
Lbs
1795
2370
2305
2450
2495
1771
--
265
kN
7.98
10.54
10.25
10.90
11.10
7.88
--
1.18
Lbs
--
--
--
--
--
--
5990
--
kN
--
--
--
--
--
--
26.65
--
Lbs
1795
2370
2305
2450
2495
1771
--
265
1.18
LVL
Uplift1
DF-L
I-Joist2
Joist
DF-L 115%
Ref. No.
Header
LSL
TFL25112
Steel Gauge
USP
Stock No.
Factored Resistance4
Header Material (100%)
Fastener Schedule2,5,6
Dimensions (in)
kN
7.98
10.54
10.25
10.90
11.10
7.88
--
Lbs
2950
2535
2535
2535
3005
2130
--
435
kN
13.12 11.28
11.28
11.28
13.37
9.48
--
1.94
--
Lbs
--
--
--
--
--
--
5990
kN
--
--
--
--
--
--
26.65
--
Lbs
1795
2370
2305
2450
2495
1771
--
265
1.18
kN
7.98
10.54
10.25
10.90
11.10
7.88
--
Lbs
1795
2370
2305
2450
2495
1771
--
265
kN
7.98
10.54
10.25
10.90
11.10
7.88
--
1.18
Lbs
3865
3865
3865
3865
4450
3160
--
435
kN
17.19 17.19
17.19
17.19
19.80
14.06
--
1.94
Lbs
--
3685
3220
3260
4190
2975
--
545
kN
--
16.39
14.32
14.50
18.64
13.23
--
2.42
Lbs
--
5140
5140
4435
4125
4125
--
--
kN
--
22.86
22.86
19.73
18.35
18.35
--
--
Lbs
--
--
--
--
--
--
5990
--
kN
--
--
--
--
--
--
26.65
--
Lbs
1795
2370
2305
2450
2495
1771
--
265
1.18
kN
7.98
10.54
10.25
10.90
11.10
7.88
--
Lbs
--
3685
3220
3260
4190
2975
--
545
kN
--
16.39
14.32
14.50
18.64
13.23
--
2.42
Lbs
--
5140
5140
4435
4125
4125
--
--
kN
--
22.86
22.86
19.73
18.35
18.35
--
--
Lbs
--
--
--
--
--
--
5990
--
kN
--
--
--
--
--
--
26.65
--
Lbs
--
3685
3220
3260
4190
2975
--
545
kN
--
16.39
14.32
14.50
18.64
13.23
--
2.42
Lbs
--
--
--
--
--
--
5990
--
kN
--
--
--
--
--
--
26.65
--
Lbs
--
3685
3220
3260
4190
2975
--
545
kN
--
16.39
14.32
14.50
18.64
13.23
--
2.42
Lbs
--
--
--
--
--
--
5990
--
kN
--
--
--
--
--
--
26.65
--
Lbs
--
4675
4205
4250
5315
3775
--
545
2.42
kN
--
20.80
18.71
18.91
23.64
16.79
--
Lbs
--
--
--
--
--
--
5990
--
kN
--
--
--
--
--
--
26.65
--
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.
3) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
4) Minimum nail embedment shall be 8 nail diameters (typ.).
6) NAILS!"
"!"
"! " !"! "
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
New products or updated product information are designated in red font.
EWP Hangers
Joist Size
continued
PSL
L
TF
H
W
USP2240-131
131
TFI324
2-1/2 x 24
MPH2524
TFI326
-- -HIT326,
LBV2.56/26,
WPI326
--
10
16d
10d x 1-1/2
12
2-1/2
24
2-1/2
3-3/4
16d duplex
10d x 1-1/2
--
16
2-9/16
26
2-1/2
--
10
16d
10d x 1-1/2
Qty
Type
MPH2526
-- --
12
2-1/2
26
2-1/2
3-3/4
16d duplex
10d x 1-1/2
2-5/8 x 9-1/2
THO26950
-- --
--
18
2-11/16
9-1/2
2-3/8
--
10
10d
10d x 1-1/2
2-5/8 x 11-7/8
THO26118
-- --
--
16
2-11/16
11-7/8
2-3/8
--
10
10d
10d x 1-1/2
2-5/8 x 14
THO26140
-- --
--
18
2-11/16
14
2-3/8
--
12
10d
10d x 1-1/2
2-5/8 x 16
THO26160
-- --
--
18
2-11/16
16
2-3/8
--
12
10d
10d x 1-1/2
2-11/16
x 9-1/4
2-11/16
x 9-1/2
2-11/16
x 11-1/4
2-11/16
x 11-7/8
Lbs
--
4675
4205
4250
5315
3775
--
545
kN
--
20.80
18.71
18.91
23.64
16.79
--
2.42
Lbs
--
--
--
--
--
--
5990
--
kN
--
--
--
--
--
--
26.65
--
Lbs
--
4675
4205
4250
5315
3775
--
545
kN
--
20.80
18.71
18.91
23.64
16.79
--
2.42
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
--2340
10.41
2640
11.74
3910
17.39
3910
17.39
------------------------------3785
16.84
-------
--2340
10.41
2640
11.74
3910
17.39
3910
17.39
8670
38.57
14725
65.50
8670
38.57
14725
65.50
8670
38.57
14725
65.50
8670
38.57
14725
65.50
8670
38.57
14725
65.50
8670
38.57
14725
65.50
5265
23.42
8670
38.57
--3355
14.92
5265
23.42
8670
38.57
---
--2340
10.41
2640
11.74
3910
17.39
3910
17.39
8330
37.06
15180
67.53
8330
37.06
15180
67.53
8330
37.06
15180
67.53
8330
37.06
15180
67.53
8330
37.06
15180
67.53
8330
37.06
15180
67.53
5055
22.49
8330
37.06
--3585
15.95
5055
22.49
8330
37.06
---
--2340
10.41
2640
11.74
3910
17.39
3910
17.39
8670
38.57
13825
61.50
8670
38.57
13825
61.50
8670
38.57
13825
61.50
8670
38.57
13825
61.50
8670
38.57
13825
61.50
8670
38.57
13825
61.50
5435
24.18
8670
38.57
--3585
15.95
5435
24.18
8670
38.57
---
--2660
11.83
3005
13.37
4450
19.80
4450
19.80
7610
33.85
13825
61.50
7610
33.85
13825
61.50
7610
33.85
13825
61.50
7610
33.85
13825
61.50
7610
33.85
13825
61.50
7610
33.85
13825
61.50
5055
22.49
7610
33.85
--4180
18.59
5055
22.49
7610
33.85
---
--1890
8.41
2130
9.48
3160
14.06
3160
14.06
5170
23.00
12840
57.12
5170
23.00
12840
57.12
5170
23.00
12840
57.12
5170
23.00
12840
57.12
5170
23.00
12840
57.12
5170
23.00
12840
57.12
4055
18.04
5170
23.00
--2970
13.21
4055
18.04
5170
23.00
---
5990
26.65
------------------------------------6165
27.42
------6165
27.42
--500
2.22
500
2.22
500
2.22
500
2.22
1005
4.47
1430
6.36
1005
4.47
1430
6.36
1005
4.47
1430
6.36
1005
4.47
1430
6.36
1005
4.47
1430
6.36
1005
4.47
1430
6.36
780
3.47
1005
8670
--2210
9.83
780
3.47
1005
4.47
---
EWP
Top-- Mount
Charts
continued
2-3/4
3-1/4
10
HWU2.75/9.25
7
9-1/4 Hanger
2-1/2
8
16d
6 10d
x 1-1/2
PHXU27925
HLBH27925
GLTV2.75/9.25
2-3/4
9-1/4
12
2-3/4
15
10d x 1-1/2
PHXU2795
-- --
--
2-3/4
9-1/2
3-1/4
10
2-1/2
16d
10d x 1-1/2
HLBH2795
GLTV2.75/9.5
2-3/4
9-1/2
12
2-3/4
15
10d x 1-1/2
PHXU27112
-- --
--
2-3/4
11-1/4
3-1/4
10
2-1/2
16d
10d x 1-1/2
GLTV2.75/11.25 x
2-3/4
11-1/4
12
2-3/4
15
10d x 1-1/2
--
2-3/4
11-7/8
3-1/4
10
2-1/2
16d
10d x 1-1/2
GLTV2.75/11.88 x
2-3/4
11-7/8
12
2-3/4
15
10d x 1-1/2
--
2-3/4
14
3-1/4
10
2-1/2
16d
10d x 1-1/2
2-3/4
14
12
2-3/4
15
10d x 1-1/2
--
2-3/4
16
3-1/4
10
2-1/2
16d
10d x 1-1/2
HLBH27112
PHXU27118
HLBH27118
PHXU2714
-- --
-- --
2-11/16 x 14
HLBH2714
PHXU2716
GLTV2.75/14
-- --
2-11/16 x 16
3 x 9-1/4
Unit
HLBH2716
GLTV2.75/16
2-3/4
16
12
2-3/4
15
10d x 1-1/2
BPH31925
LBV3.12/9.25
12
3-1/8
9-1/4
--
2-3/32
10
16d
10d
PHXU31925
WP29.25-2
3-1/8
9-1/4
3-1/4
10
2-1/2
16d
10d x 1-1/2
MPH210-2
WM29.25-2
12
3-1/8
9-1/4
2-1/2
3-3/4
16d duplex
10d
THO15950-2
LT2-159,
MIT29.5-2
16
3-1/16
9-1/2
2-3/8
--
1-1/2
10
16d
10d
BPH3195
LBV3.12/9.5
12
3-1/8
9-1/2
--
2-3/32
10
16d
10d
PHXU3195
WP29.5-2
3-1/8
9-1/2
3-1/4
10
2-1/2
16d
10d x 1-1/2
MPH1595-2
WM29.5-2
12
3-1/8
9-1/2
2-1/2
3-3/4
16d duplex
10d
3 x 9-1/2
LVL
Type
DF-L 115%
2-1/2
Qty
Masonry3
24
TF
Uplift1
SPF
2-9/16
DF-L
16
LSL
--
PSL
Joist
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) When I-joist is used as a header, all nails must be 10d x 1-1/2.
3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.
4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
5) Minimum nail embedment shall be 8 nail diameters (typ.).
6) NAILS:
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
L
TF
H
W
132
2-1/2 x 26
Ref. No.
HIT324,
LBV2.56/24,
WPI324
Header
DF-L
I-Joist2
USP
Stock No.
Factored Resistance4
Header Material (100%)
Fastener Schedule2,5,6
Dimensions (in)
Joist Size
continued
Steel Gauge
EWP Hangers
TF
Qty
Type
Qty
Type
12
3-1/8
11-1/4
--
2-3/32
10
16d
10d
3-1/8
11-1/4
3-1/4
10
2-1/2
16d
10d x 1-1/2
MPH15112-2
WM211.25-2
12
3-1/8
11-1/4
2-1/2
3-3/4
16d duplex
10d
THO15118-2
LT2-151188,
MIT211.88-2
16
3-1/16
11-7/8
2-3/8
--
1-1/2
10
16d
10d
BPH31118
LBV3.12/11.88
12
3-1/8
11-7/8
--
2-3/32
10
16d
10d
PHXU31118
WP211.88-2
3-1/8
11-7/8
3-1/4
10
2-1/2
16d
10d x 1-1/2
3 x 11-7/8
MPH15118-2
BPH3114
WM211.88-2
LBV3.12/14
x
x
12
12
3-1/8
3-1/8
11-7/8
14
2-1/2
3
7
--
3-3/4
2-3/32
2
10
16d duplex
16d
2
4
10d
10d
3 x 14
PHXU3114
3-1/2 x 7-1/4
3-1/8
14
3-1/4
10
2-1/2
16d
10d x 1-1/2
PHXU35725
WPU3.56/7.25
3-9/16
7-1/4
3-1/4
10
2-1/2
16d
10d
THO35925
LT35925
--
16
3-9/16
9-1/4
2-3/8
--
2-1/2
10
10d
10d x 1-1/2
12
3-9/16
9-1/4
2-3/8
--
2-3/8
10
16d
10d
3-5/8
9-1/4
2-1/2
16d
10d
BPH35925
LBV3.56/9.25
PHM35925
WPI49.25
PHXU35925
HB3.56/9.25,
HWI49.25,
HWU3.56/9.25
3-1/2 x 9-1/4
HLBH35925
3-1/2 x 9-3/8
-- --
-- --
x 7/10
x
x
7
7
3-9/16
3-5/8
9-1/4
9-1/4
3-1/4
6
10
12
2-1/2
3-1/8
8
15
16d
6
6
10d
16d
MPH410
WM410
--
12
3-9/16
9-1/4
2-1/2
3-3/4
16d duplex
10d
THO35938
LT359375
--
16
3-9/16
9-3/8
2-3/8
--
2-9/16
10
10d
10d x 1-1/2
Masonry3
WP211.25-2
SPF
PHXU31112
Lbs
--
5265
5055
5435
5055
4055
--
780
kN
--
23.42
22.49
24.18
22.49
18.04
--
3.47
LVL
LBV3.12/11.25
Unit
DF-L
I-Joist2
BPH31112
Uplift1
DF-L 115%
Joist
DF-L
Ref. No.
Header
LSL
Steel Gauge
3 x 11-1/4
USP
Stock No.
Factored Resistance4
Header Material (100%)
Fastener Schedule2,5,6
Dimensions (in)
Lbs
--
8670
8330
8670
7610
5170
--
1005
kN
--
38.57
37.06
38.57
33.85
23.00
--
4.47
Lbs
--
--
--
--
--
--
6165
--
kN
--
--
--
--
--
--
27.42
--
Lbs
3785
3355
3550
3550
4150
2945
--
2210
9.83
kN
16.84
14.92
15.79
15.79
18.46
13.10
--
Lbs
--
5265
5055
5435
5055
4055
--
780
kN
--
23.42
22.49
24.18
22.49
18.04
--
3.47
Lbs
--
8670
8330
8670
7610
5170
--
1005
kN
--
38.57
37.06
38.57
33.85
23.00
--
4.47
Lbs
--
--
--
--
--
--
6165
--
kN
--
--
--
--
--
--
27.42
--
Lbs
--
5265
5055
5435
5055
4055
--
780
kN
--
23.42
22.49
24.18
22.49
18.04
--
3.47
Lbs
--
8670
8330
8670
7610
5170
--
1005
kN
--
38.57
37.06
38.57
33.85
23.00
--
4.47
Lbs
--
9575
8330
9245
7610
5170
--
1290
5.74
kN
--
42.59
37.06
41.13
33.85
23.00
--
Lbs
2950
2950
2950
2950
2975
2115
--
500
kN
13.12
13.12
13.12
13.12
13.23
9.41
--
2.22
Lbs
--
5300
5055
5435
5055
4725
--
830
kN
--
23.58
22.49
24.18
22.49
21.02
--
3.69
Lbs
--
5395
5140
4435
4685
4685
--
--
kN
--
24.00
22.86
19.73
20.84
20.84
--
--
Lbs
--
9575
8330
9245
7610
5170
--
1290
41.13
33.85
kN
--
42.59
37.06
23.00
--
5.74
Lbs
--
15295
--
1770
7.87
kN
--
68.04
67.68
61.50
61.50
57.12
--
Lbs
--
--
--
--
--
--
6165
--
kN
--
--
--
--
--
--
27.42
--
Lbs
2950
2950
2950
2950
2975
2115
--
500
kN
13.12
13.12
13.12
13.12
13.23
9.41
--
2.22
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) When I-joist is used as a header, all nails must be 10d x 1-1/2.
3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.
4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
5) Minimum nail embedment shall be 8 nail diameters (typ.).
6) NAILS: !
! !
!
!
!
!
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
New products or updated product information are designated in red font.
L
TF
H
W
EWP Hangers
Joist Size
continued
PSL
USP2240-131
133
TF
Qty
Type
Qty
Type
LT359
--
16
3-9/16
9-1/2
2-3/8
--
2-7/16
10
10d
10d x 1-1/2
THO17950-2
MIT49.5
16
3-9/16
9-1/2
2-3/8
--
1-9/16
10
16d
10d
BPH3595
LBV3.56/9.5
12
3-9/16
9-1/2
2-3/8
--
2-3/8
10
16d
10d
PHM3595
WPI49.5
x 7/10
3-5/8
9-1/2
2-1/2
16d
10d
PHXU3595
GLTV3.59,
HB3.56/9.5,
HWI49.5,
HWU3.56/9.5
3-9/16
9-1/2
3-1/4
10
2-1/2
16d
10d
3-1/2 x 11-1/4
9-1/2
12
3-1/8
15
MPH1795-2
WM3.56/9.5
--
12
3-5/8
9-1/2
2-1/2
3-3/4
16d duplex
THO35112
LT351125
--
16
3-9/16
11-1/4
2-3/8
--
2-1/2
10
10d
12
3-9/16
11-1/4
2-3/8
--
2-3/8
10
16d
3-9/16
11-1/4
3-1/4
10
2-1/2
16d
BPH35112
LBV3.56/11.25
GLTV3.56/11.25,
HB3.56/11.25,
PHXU35112 HWI411.25,
HWU3.56/11.25,
WPI411.25
3-5/8
11-1/4
12
3-1/8
15
16d
MPH412
WM412
--
12
3-9/16
11-1/4
2-1/2
3-3/4
16d duplex
10d
THO35118
LT351188
--
18
3-9/16
11-7/8
2-3/8
--
2-1/2
10
10d
10d x 1-1/2
THO17118-2
MIT411.88
16
3-9/16
11-7/8
2-3/8
--
1-9/16
10
16d
10d
12
3-9/16
11-7/8
2-3/8
--
2-3/8
10
16d
10d
PHM35118
WPI411.88
x 7/10
3-5/8
11-7/8
2-1/2
16d
10d
PHXU35118
GLTV3.511,
HB3.56/11.88,
HWI411.88,
HWU3.56/11.88,
WPU3.56/11.88
3-9/16
11-7/8
3-1/4
10
2.5
16d
10d
HLBH35118
HGLTV3.511
3-5/8
11-7/8
12
3-1/8
15
MPH17118-2
WM3.56/11.88
--
12
3-5/8
11-7/8
2-1/2
3-3/4
16d duplex
-- --
--
18
3-9/16
12
2-3/8
--
2-1/2
10
10d
BPH3512
HWI412,
LBV3.56/12
12
3-9/16
12
2-3/4
--
2-1/32
10
16d
PHXU3512
GLTV3.512,
HB3.56/12
3-9/16
12
3-1/4
10
2-1/2
16d
HLBH3512
HGLTV3.512
3-5/8
12
12
3-1/8
15
MPH3512
WMI412
--
12
3-1/2
12
2-1/2
3-3/4
16d duplex
THO35120
2115
9.41
3100
13.79
4725
21.02
4685
20.84
---------
500
2.22
2210
9.83
830
3.69
---
Lbs
--
9575
8330
9245
7610
5170
--
1290
kN
--
42.59
37.06
41.13
33.85
23.00
--
5.74
--6165
27.42
-----
1770
7.87
--500
2.22
830
3.69
1290
----2950
13.12
---
Lbs
--
LVL
2975
13.23
4370
19.44
5055
22.49
4685
20.84
DF-L
I-Joist2
2950
13.12
3680
16.37
5435
24.18
4435
19.73
8330
9245
7610
5170
--
42.59
37.06
41.13
33.85
23.00
--
5.74
--6165
27.42
---------
1770
7.87
--500
2.22
2210
9.83
830
3.69
---
5170
--
1290
--
10d
HGLTV3.56/11.25
3-1/2 x 11-7/8
2950
13.12
3680
16.37
5055
22.49
5140
22.86
Lbs
16d
kN
Lbs
10d
kN
Lbs
10d x 1-1/2
kN
Lbs
10d
kN
HLBH35112
LBV3.56/11.88
DF-L 115%
3-5/8
Masonry3
SPF
Unit
Lbs 2950 2950
kN 13.12 13.12
Lbs 3785 3355
kN 16.84 14.92
Lbs
-5300
kN
-23.58
Lbs
-5395
kN
-24.00
DF-L
HGLTV3.59
Uplift1
LSL
HLBH3595
BPH35118
3-1/2 x 12
Joist
PSL
3-1/2 x 9-1/2
Ref. No.
Header
kN
--
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
----2535
11.28
3785
16.84
-----
Lbs
--
kN
--
42.59
37.06
41.13
33.85
23.00
----2950
13.12
---------
15295
68.04
--2950
13.12
5300
23.58
9575
42.59
15295
68.04
---
15215
67.68
--2950
13.12
5055
22.49
8330
37.06
15215
67.68
---
13825
61.50
--2950
13.12
5435
24.18
9245
41.13
13825
61.50
---
13825
61.50
--2975
13.23
5055
22.49
7610
33.85
13825
61.50
---
12840
-57.12
--6165
-27.42
2115
-9.41
-4725
-21.02
-5170
-23.00
-12840
-57.12
--6165
-27.42
Lbs
16d
kN
Lbs
10d
kN
Lbs
10d x 1-1/2
kN
Lbs
10d
kN
Lbs
10d
kN
Lbs
16d
kN
Lbs
10d
kN
8330
9245
7610
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) When I-joist is used as a header, all nails must be 10d x 1-1/2.
3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.
4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
5) Minimum nail embedment shall be 8 nail diameters (typ.).
6) NAILS:! ""! ""!
"
!
!
"!
"
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
L
TF
H
W
134
5.74
1770
7.87
--500
2.22
1245
5.54
1335
5.94
1770
7.87
---
THO35950
USP
Stock No.
Factored Resistance4
Header Material (100%)
Fastener Schedule2,5,6
Dimensions (in)
Joist Size
continued
Steel Gauge
EWP Hangers
TF
Qty
Type
Qty
3-9/16
13
2-3/8
--
2-1/2
10
10d
THO35140
LT3514
--
18
3-9/16
14
2-3/8
--
2-1/2
12
10d
TFI414
MIT414
--
16
3-9/16
14
2-1/2
--
2-1/8
16d
12
3-9/16
14
2-3/4
--
2-1/32
10
16d
10d
BPH3514
B3.56/14,
LBV3.56/14
WPI414
7/10
3-5/8
14
2-1/2
16d
10d
PHXU3514
GLTV3.514,
HB3.56/14,
HWI414,
HWU3.56/14,
WPU3.56/14
3-9/16
14
3-1/4
10
2.5
16d
10d
3-5/8
14
12
3-1/8
15
MPH3514
WMI414
--
12
3-1/2
14
2-1/2
3-3/4
16d duplex
THO35160
LT3516
--
18
3-9/16
16
2-3/8
--
2-1/2
12
10d
TFI416
MIT416
--
16
3-9/16
16
2-1/2
--
2-1/8
16d
12
3-9/16
16
2-3/4
--
2-1/32
10
16d
10d
BPH3516
2115
9.41
3160
14.06
2975
13.23
-------
500
2.22
500
2.22
545
2.42
--
5300
5055
5435
5055
4725
--
1245
--
23.58
22.49
24.18
22.49
21.02
--
5.54
Lbs
kN
---
5395
24.00
5140
22.86
4435
19.73
4685
20.84
4685
20.84
---
---
Lbs
--
9575
8330
9245
7610
5170
--
1290
--
--
42.59
37.06
41.13
33.85
23.00
----3910
17.39
---
15295
68.04
--3910
17.39
3685
16.39
15215
67.68
--3910
17.39
3220
14.32
13825
61.50
--3910
17.39
3260
14.50
13825
61.50
--4450
19.80
4190
18.64
12840
-57.12
--6165
-27.42
3160
-14.06
-2975
-13.23
--
1770
7.87
--500
2.22
545
2.42
5.74
--
5300
5055
5435
5055
4725
--
1245
kN
--
23.58
22.49
24.18
22.49
21.02
--
5.54
Lbs
kN
---
5395
24.00
5140
22.86
4435
19.73
4685
20.84
4685
20.84
---
---
Lbs
--
9575
8330
9245
7610
5170
--
1290
kN
--
42.59
37.06
41.13
33.85
23.00
--
5.74
Lbs
kN
Lbs
10d
kN
Lbs
10d x 1-1/2
kN
Lbs
10d
kN
Lbs
10d
kN
-----------
15295
68.04
--3685
16.39
5300
23.58
5395
24.00
15215
67.68
--3220
14.32
5055
22.49
5140
22.86
13825
61.50
--3260
14.50
5435
24.18
4435
19.73
13825
61.50
--4190
18.64
5055
22.49
4685
20.84
12840
-57.12
--6165
-27.42
2975
-13.23
-4725
-21.02
-4685
-20.84
--
1770
7.87
--545
2.42
1245
5.54
---
Lbs
--
9575
8330
9245
7610
5170
--
1290
kN
--
42.59
37.06
41.13
33.85
23.00
--
5.74
Lbs
kN
Lbs
kN
-----
WPI416
7/10
3-5/8
16
2-1/2
16d
10d
PHXU3516
GLTV3.516,
HB3.56/16,
HWI416,
HWU3.56/16,
WPU3.56/16
3-9/16
16
3-1/4
10
2-1/2
16d
10d
HLBH3516
HGLTV3.516
3-5/8
16
12
3-1/8
15
MPH3516
WMI416
--
12
3-1/2
16
2-1/2
3-3/4
16d duplex
TFI418
HIT418,
MIT418
--
16
3-9/16
18
2-1/2
--
2-1/8
16d
BPH3518
LBV3.56/18
12
3-9/16
18
2-3/4
--
2-1/32
10
16d
PHM3518
WPI418
7/10
3-5/8
18
2-1/2
16d
PHXU3518
GLTV3.518,
HB3.56/18,
HWI418,
HWU3.56/18,
WPU3.56/18
3-9/16
18
3-1/4
10
2-1/2
16d
HLBH3518
HGLTV3.518
3-5/8
18
12
3-1/8
15
16d
MPH3518
WMI418
12
3-1/2
18
2-1/2
3-3/4
16d duplex
10d
3-1/2 x 18
2975
13.23
4450
19.80
4190
18.64
Lbs
PHM3516
3-1/2 x 16
2950
13.12
3910
17.39
3260
14.50
kN
kN
HGLTV3.514
2950
13.12
3910
17.39
3220
14.32
Lbs
Lbs
16d
kN
Lbs
10d
kN
Lbs
10d x 1-1/2
kN
Lbs
10d x 1-1/2
kN
HLBH3514
B3.56/16,
LBV3.56/16
LVL
Unit
Lbs 2950 2950
kN 13.12 13.12
Lbs 3910 3910
10d x 1-1/2
kN 17.39 17.39
Lbs
-3685
10d x 1-1/2
kN
-16.39
PHM3514
3-1/2 x 14
DF-L
I-Joist2
Type
10d x 1-1/2
DF-L 115%
18
Masonry3
--
Ref. No.
Uplift1
SPF
LT3513
Joist
DF-L
Steel Gauge
THO35130
Header
LSL
3-1/2 x 13
USP
Stock No.
Factored Resistance4
Header Material (100%)
Fastener Schedule2,5,6
Dimensions (in)
16d
EWP Hangers
Joist Size
continued
PSL
10d
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) When I-joist is used as a header, all nails must be 10d x 1-1/2.
3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.
4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
5) Minimum nail embedment shall be 8 nail diameters (typ.).
6) NAILS:! ""! ""!
"
!
!
"!
"
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
1770
7.87
---
L
TF
H
W
USP2240-131
135
TFI420
MIT420
--
16
3-9/16
20
2-1/2
--
2-1/8
16d
BPH3520
HIT420,
LBV3.56/20
12
3-9/16
20
2-3/4
--
2-1/32
10
16d
PHM3520
WPI420
7/10
3-5/8
20
2-1/2
16d
PHXU3520
HB3.56/20,
HWI420,
WPU3.56/20
3-9/16
20
3-1/4
10
2-1/2
16d
3-5/8
20
12
3-1/8
15
MPH3520
WMI420
12
3-1/2
20
2-1/2
3-3/4
16d duplex
TFI422
HIT422
--
16
3-9/16
22
2-1/2
--
2-1/8
10
16d
BPH3522
HIT3522,
LBV3.56/22
12
3-9/16
22
2-3/4
--
2-1/32
10
16d
PHM3522
HWI422,
WPI422
7/10
3-5/8
22
2-1/2
16d
PHXU3522
HB3.56/22
WPU3.56/22
3-9/16
22
3-1/4
10
2-1/2
16d
TFI424
HIT424,
LBV3.56/24
--
16
3-9/16
24
2-1/2
--
2-1/8
10
16d
BPH3524
-- --
12
3-9/16
24
2-3/4
--
2-1/32
10
16d
PHM3524
HWI424,
WPI424
7/10
3-5/8
24
2-1/2
16d
PHXU3524
HB3.56/24,
WPU3.56/24
3-9/16
24
3-1/4
10
2-1/2
16d
TFI426
HIT426
--
16
3-9/16
26
2-1/2
--
2-1/8
10
16d
BPH3526
LBV3.56/26
12
3-9/16
26
2-3/4
--
2-1/32
10
16d
PHM3526
HWI426,
WPI426
7/10
3-5/8
26
2-1/2
16d
PHXU3526
HB3.56/26,
WPU3.56/26
3-9/16
26
3-1/4
10
2-1/2
16d
BPH3528
LBV3.56/28
12
3-9/16
28
2-3/4
--
2-1/32
10
16d
PHM3528
HWI428,
WPI428
7/10
3-5/8
28
2-1/2
16d
PHXU3528
HB3.56/28,
WPU3.56/28
3-9/16
28
3-1/4
10
2-1/2
16d
BPH3530
LBV3.56/30
12
3-9/16
30
2-3/4
--
2-1/32
10
16d
PHM3530
HWI430,
WPI430
7/10
3-5/8
30
2-1/2
16d
PHXU3530
HB3.56/30
3-9/16
30
3-1/4
10
2-1/2
16d
3-1/2 x 26
BPH3532
-- --
12
3-9/16
32
2-3/4
--
2-1/32
10
16d
PHM3532
HWI432,
WPI432
7/10
3-5/8
32
2-1/2
16d
-- --
3-9/16
32
3-1/4
10
2-1/2
16d
PHXU3532
DF-L 115%
Unit
Lbs
10d x 1-1/2
kN
Lbs
10d
kN
Lbs
10d
kN
Masonry3
Type
SPF
Qty
DF-L
Type
LSL
Qty
PSL
TF
3-1/2 x 24
3-1/2 x 32
3-1/2 x 22
3-1/2 x 30
-- --
HLBH3520
3-1/2 x 28
Uplift1
LVL
3-1/2 x 20
Ref. No.
Factored Resistance4
Header Material (100%)
Joist
DF-L
I-Joist2
USP
Stock No.
Header
-------
3685
16.39
5300
23.58
5395
24.00
3220
14.32
5055
22.49
5140
22.86
3260
14.50
5435
24.18
4435
19.73
4190
18.64
5055
22.49
4685
20.84
2975
13.23
4725
21.02
4685
20.84
-------
545
2.42
1245
5.54
---
Lbs
--
9575
8330
9245
7610
5170
--
kN
--
42.59
37.06
41.13
33.85
23.00
--
Lbs
16d
kN
Lbs
10d
kN
Lbs
10d x 1-1/2
kN
Lbs
10d
kN
Lbs
10d
kN
Lbs
10d
kN
Lbs
10d x 1-1/2
kN
Lbs
10d
kN
Lbs
10d
kN
Lbs
10d
kN
Lbs
10d x 1-1/2
kN
Lbs
10d
kN
Lbs
10d
kN
Lbs
10d
kN
Lbs
10d
kN
Lbs
10d
kN
Lbs
10d
kN
Lbs
10d
kN
Lbs
10d
kN
Lbs
10d
kN
Lbs
10d
kN
Lbs
10d
kN
Lbs
10d
kN
-----------------------------------------------
15295
68.04
--4675
20.80
5300
23.58
5395
24.00
9575
42.59
4675
20.80
5300
23.58
5395
24.00
9575
42.59
4675
20.80
5300
23.58
5395
24.00
9575
42.59
5300
23.58
5395
24.00
9575
42.59
5300
23.58
5395
24.00
9575
42.59
5300
23.58
5395
24.00
9575
42.59
15215
67.68
--4205
18.71
5055
22.49
5140
22.86
8330
37.06
4205
18.71
5055
22.49
5140
22.86
8330
37.06
4205
18.71
5055
22.49
5140
22.86
8330
37.06
5055
22.49
5140
22.86
8330
37.06
5055
22.49
5140
22.86
8330
37.06
5055
22.49
5140
22.86
8330
37.06
13825
61.50
--4250
18.91
5435
24.18
4435
19.73
9245
41.13
4250
18.91
5435
24.18
4435
19.73
9245
41.13
4250
18.91
5435
24.18
4435
19.73
9245
41.13
5435
24.18
4435
19.73
9245
41.13
5435
24.18
4435
19.73
9245
41.13
5435
24.18
4435
19.73
9245
41.13
13825
61.50
--5315
23.64
5055
22.49
4685
20.84
7610
33.85
5315
23.64
5055
22.49
4685
20.84
7610
33.85
5315
23.64
5055
22.49
4685
20.84
7610
33.85
5055
22.49
4685
20.84
7610
33.85
5055
22.49
4685
20.84
7610
33.85
5055
22.49
4685
20.84
7610
33.85
12840
-57.12
--6165
-27.42
3775
-16.79
-4725
-21.02
-4685
-20.84
-5170
-23.00
-3775
-16.79
-4725
-21.02
-4685
-20.84
-5170
-23.00
-3775
-16.79
-4725
-21.02
-4685
-20.84
-5170
-23.00
-4725
-21.02
-4685
-20.84
-5170
-23.00
-4725
-21.02
-4685
-20.84
-5170
-23.00
-4725
-21.02
-4685
-20.84
-5170
-23.00
--
10d
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) When I-joist is used as a header, all nails must be 10d x 1-1/2.
3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.
4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
5) Minimum nail embedment shall be 8 nail diameters (typ.).
6) NAILS:
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
5.74
1770
7.87
--545
2.42
1245
5.54
--1335
5.94
545
2.42
1245
5.54
--1335
5.94
545
2.42
1245
5.54
--1335
5.94
1245
5.54
--1335
5.94
1245
5.54
--1335
5.94
1245
5.54
--1335
5.94
L
TF
H
W
136
1290
Joist Size
continued
Fastener Schedule2,5,6
Dimensions (in)
Steel Gauge
EWP Hangers
4 - 4-3/16
x 11-7/8
LBV4.12/11.88,
THO20118-2 LBV4.28/11.88,
MIT4.28/11.88
PHM42118
4 - 4-3/16
x 14
-- --
LBV4.12/14,
THO20140-2 LBV4.28/14,
MIT4.28/14
PHM4214
4 - 4-3/16
x 16
THO20160-2
PHM4216
-- -LBV4.12/16,
LBV4.28/16
-- --
TF
Qty
Type
Qty
Type
16
4-3/16
9-1/2
--
10
16d
10d
x
x
x
16
7/10
12
4-3/16
4-3/16
4-3/16
4-3/16
9-1/2
11-7/8
11-7/8
14
2-1/2
3
2-1/2
3
7
-7
--
3
2
3
1-15/16
2
10
2
10
16d
16d
16d
16d
2
6
2
6
10d
10d
10d
10d
7/10
4-3/16
14
2-1/2
16d
10d
12
4-3/16
16
--
1-15/16
10
16d
10d
7/10
4-3/16
16
2-1/2
16d
10d
THO23950-2
LBV4.75/9.5,
MIT359.5-2
12
4-3/4
9-1/2
--
10
16d
10d
PHM2395-2
WP359.5-2
7/10
4-3/4
9-1/2
2-1/2
16d
10d
THO23118-2
LBV4.75/11.88,
MIT3511.88-2
12
4-3/4
11-7/8
--
2-1/8
10
16d
10d
4-1/2 - 4-5/8
PHM23118-2 WP3511.88-2
x 11-7/8
7/10
4-3/4
11-7/8
2-1/2
16d
10d
MPH23118-2 WM3511.88-2
12
4-5/8
11-7/8
2-1/2
3-3/4
16d duplex
10d
12
4-3/4
14
--
2-1/8
12
16d
10d
4-1/2 - 4-5/8
x 9-1/2
4-1/2 - 4-5/8
x 14
4-1/2 - 4-5/8
x 16
THO23140-2
WM3514-2
12
4-5/8
14
2-1/2
3-3/4
16d duplex
10d
THO23160-2 LBV4.75/16
12
4-3/4
16
--
2-1/8
12
16d
10d
MPH2314-2
PHM2316-2
MPH2316-2
4-1/2 - 4-5/8
x 18
LBV4.75/14,
MIT3514-2
WP3516-2
7/10
4-3/4
16
2-1/2
16d
10d
WM3516-2
12
4-5/8
16
2-1/2
3-3/4
16d duplex
10d
THO23180-2 LBV4.75/18
12
4-3/4
18
--
2-1/8
14
16d
10d
PHM2318-2
MPH2318-2
WP3518-2
WM3518-2
x
x
7/10
12
4-3/4
4-5/8
18
18
2-1/2
2-1/2
7
7
3
3-3/4
2
2
16d
16d duplex
2
2
10d
10d
DF-L 115%
7/10
Masonry3
Uplift1
Lbs
3785
3355
3840
3840
4370
3100
--
2210
kN
16.84 14.92
17.08
17.08
19.44
13.79
--
9.83
--
Unit
SPF
DF-L
LSL
Joist
LVL
-- --
Header
DF-L
I-Joist2
PHM4295
Ref. No.
LBV4.12/9.5,
THO20950-2 LBV4.28/9.5,
MIT4.28/9.5
Steel Gauge
4 - 4-3/16
x 9-1/2
USP
Stock No.
Factored Resistance4
Header Material (100%)
Fastener Schedule2,5,6
Dimensions (in)
Lbs
--
5395
5140
4435
4685
4685
--
kN
--
24.00
22.86
19.73
20.84
20.84
--
--
Lbs
3785
3355
3890
3890
4820
3425
--
2210
kN
16.84 14.92
17.30
17.30
21.44
15.24
--
9.83
Lbs
--
5395
5140
4435
4685
4685
--
--
kN
--
24.00
22.86
19.73
20.84
20.84
--
--
Lbs
3785
3355
5330
5330
6060
4305
--
2210
kN
16.84 14.92
23.71
23.71
26.96
19.15
--
9.83
Lbs
--
5395
5140
4435
4685
4685
--
--
kN
--
24.00
22.86
19.73
20.84
20.84
--
--
Lbs
3785
3355
5330
5330
6060
4305
--
2210
kN
16.84 14.92
23.71
23.71
26.96
19.15
--
9.83
Lbs
--
5395
5140
4435
4685
4685
--
--
kN
--
24.00
22.86
19.73
20.84
20.84
--
--
Lbs
3785
5090
5235
5235
6005
4265
--
2210
kN
16.84 22.64
9.83
23.29
23.29
26.71
18.97
--
Lbs
--
5395
4685
4270
4685
4685
--
--
kN
--
24.00
20.84
18.99
20.84
20.84
--
--
Lbs
3785
5090
5280
5280
6005
4265
--
2210
kN
16.84 22.64
23.49
23.49
26.71
18.97
--
9.83
Lbs
--
5395
4685
4270
4685
4685
--
--
kN
--
24.00
20.84
18.99
20.84
20.84
--
--
Lbs
--
--
--
--
--
--
6165
--
kN
--
--
--
--
--
--
27.42
--
Lbs
3785
5090
6345
6345
7290
5175
--
2210
kN
16.84 22.64
28.23
28.23
32.43
23.02
--
9.83
Lbs
--
--
--
--
--
--
6165
--
kN
--
--
--
--
--
--
27.42
--
Lbs
3785
5090
6345
6345
7290
5175
--
2210
kN
16.84 22.64
28.23
28.23
32.43
23.02
--
9.83
Lbs
--
5395
4685
4270
4685
4685
--
--
kN
--
24.00
20.84
18.99
20.84
20.84
--
--
Lbs
--
--
--
--
--
--
6165
--
kN
--
--
--
--
--
--
27.42
--
Lbs
3785
5090
6745
6745
9500
6745
--
2210
kN
16.84 22.64
30.00
30.00
42.26
30.00
--
9.83
Lbs
--
5395
4685
4270
4685
4685
--
--
kN
--
24.00
20.84
18.99
20.84
20.84
--
--
Lbs
--
--
--
--
--
--
6165
--
kN
--
--
--
--
--
--
27.42
--
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) When I-joist is used as a header, all nails must be 10d x 1-1/2.
3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.
4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
5) Minimum nail embedment shall be 8 nail diameters (typ.).
6) NAILS:
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
L
TF
H
W
EWP Hangers
Joist Size
continued
PSL
USP2240-131
137
continued
TF
Qty
Type
Qty
Type
LBV4.75/20
12
4-3/4
20
--
2-1/8
14
16d
10d
PHM2320-2
WP3520-2
7/10
4-3/4
20
2-1/2
16d
10d
MPH2320-2
WM3520-2
12
4-5/8
20
2-1/2
3-3/4
16d duplex
10d
THO25925-2
LBV5.12/9.25
12
5-1/8
9-1/4
--
2-11/16
10
16d
10d
THO25950-2
MIT39.5-2,
LBV5.12/9.5
12
5-1/8
9-1/2
--
2-1/8
10
16d
10d
PHM2595-2
WPI39.5-2
7/10
5-1/8
9-1/2
2-1/2
16d
10d
5 x 11-1/4
THO25112-2
LBV5.12/11.25
12
5-1/8
11-1/4
--
2-1/8
10
16d
10d
5 x 11-7/8
THO25118-2
LBV5.12/11.88,
MIT311.88-2
12
5-1/8
11-7/8
--
2-1/8
10
16d
10d
THO25140-2
MIT314-2,
LBV5.12/14
12
5-1/8
14
--
2-1/8
12
16d
10d
PHM2514-2
WPI314-2
7/10
5-1/8
14
2-1/2
16d
10d
THO25160-2
MIT5.12/16,
LBV5.12/16
12
5-1/8
16
--
2-1/8
12
16d
10d
PHM2516-2
WPI316-2
7/10
5-1/8
16
2-1/2
16d
10d
THO25180-2
B5.12/18
12
5-1/8
18
--
2-1/8
14
16d
10d
PHM2518-2
WPI318-2
7/10
5-1/8
18
2-1/2
16d
10d
THO25200-2
B5.12/20
12
5-1/8
20
--
2-1/8
14
16d
10d
PHM2520-2
WPI320-2
7/10
5-1/8
20
2-1/2
16d
10d
5 x 22
PHM2522-2
WPI322-2
7/10
5-1/8
22
2-1/2
16d
10d
5 x 24
PHM2524-2
WPI324-2
7/10
5-1/8
24
2-1/2
16d
10d
5 x 26
PHM2526-2
WPI326-2
7/10
5-1/8
26
2-1/2
16d
10d
5-1/4 x 7-1/4
BPH55725
HB5.50/7.25
10
5-9/16
7-1/4
2-1/4
--
2-1/2
10
16d
10d
PHXU55925
GLTV5.50/9.25,
HB5.50/9.25,
HWU5.50/9.25
5-1/2
9-1/4
3-1/4 11-1/2
2-1/2
16d
10d
5-1/4 x 9-1/4
5-1/4 x 9-1/2
HLBH55925
-- --
5-9/16
9-1/4
12
3-1/8
15
16d
BPH5595
-- --
12
5-9/16
9-1/2
--
2-1/6
10
16d
10d
PHM5595
WP5.50/9.5
7/10
5-5/8
9-1/2
2-1/2
16d
10d
PHXU5595
GLTV5.59,
HB5.50/9.5,
HWU5.50/9.5
5-1/2
9-1/2
3-1/4
11.5
2-1/2
16d
10d
HLBH5595
HGLTV5.59
5-9/16
9-1/2
12
3-1/8
15
16d
MPH5595
WM5.50/9.5
12
5-5/8
9-1/2
2-1/2
3-3/4
16d duplex
10d
DF-L
I-Joist2
DF-L 115%
5 x 20
Masonry3
5 x 18
SPF
5 x 16
DF-L
5 x 14
Lbs 3785
kN 16.84
Lbs
-kN
-Lbs
-kN
-Lbs 3785
kN 16.84
Lbs 3785
kN 16.84
Lbs
-kN
-Lbs 3785
kN 16.84
Lbs 3785
kN 16.84
Lbs 3785
kN 16.84
Lbs
-kN
-Lbs 3785
kN 16.84
Lbs
-kN
-Lbs 3785
kN 16.84
Lbs
-kN
-Lbs 3785
kN 16.84
Lbs
-kN
-Lbs
-kN
-Lbs
-kN
-Lbs
-kN
-Lbs
-kN
--
LSL
5 x 9-1/2
Unit
Uplift1
PSL
5 x 9-1/4
Joist
LVL
4-1/2 - 4-5/8
x 20
USP
Stock No.
Header
5090
22.64
5395
24.00
--5090
22.64
5090
22.64
5395
24.00
5090
22.64
5090
22.64
5090
22.64
5395
24.00
5090
22.64
5395
24.00
5090
22.64
5395
24.00
5090
22.64
5395
24.00
5395
24.00
5395
24.00
5395
24.00
5300
23.58
6745
30.00
4685
20.84
--5280
23.49
5280
23.49
4685
20.84
5280
23.49
5280
23.49
6345
28.23
4685
20.84
6345
28.23
4685
20.84
6745
30.00
4685
20.84
6745
30.00
4685
20.84
4685
20.84
4685
20.84
4685
20.84
5055
22.49
6745
30.00
4270
18.99
--5280
23.49
5280
23.49
4270
18.99
5280
23.49
5280
23.49
6345
28.23
4270
18.99
6345
28.23
4270
18.99
6745
30.00
4270
18.99
6745
30.00
4270
18.99
4270
18.99
4270
18.99
4270
18.99
5435
24.18
9500
42.26
4685
20.84
--6005
26.71
6005
26.71
4685
20.84
6005
26.71
6005
26.71
6645
29.56
4685
20.84
6645
29.56
4685
20.84
9500
42.26
4685
20.84
9500
42.26
4685
20.84
4685
20.84
4685
20.84
4685
20.84
5055
22.49
6745
30.00
4685
20.84
--4265
18.97
4265
18.97
4685
20.84
4265
18.97
4265
18.97
4715
20.97
4685
20.84
4715
20.97
4685
20.84
6745
30.00
4685
20.84
6745
30.00
4685
20.84
4685
20.84
4685
20.84
4685
20.84
4725
21.02
----6165
27.42
-----------------------------------
2210
9.83
----2210
9.83
2210
9.83
--2210
9.83
2210
9.83
2210
9.83
--2210
9.83
--2210
9.83
--2210
9.83
--------1245
5.54
Lbs
--
9575
8330
9575
7610
5170
--
kN
--
42.59
37.06
42.59
33.85
23.00
--
5.74
Lbs
kN
Lbs
kN
Lbs
kN
-------
-------
1770
7.87
1245
5.54
---
Lbs
--
9575
8330
9575
7610
5170
--
1290
kN
--
42.59
37.06
42.59
33.85
23.00
--
5.74
Lbs
kN
Lbs
kN
-----
--6165
27.42
1770
7.87
---
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) When I-joist is used as a header, all nails must be 10d x 1-1/2.
3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.
4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
5) Minimum nail embedment shall be 8 nail diameters (typ.).
6) NAILS
!
!
!
!
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
New products or updated product information are designated in red font.
L
TF
H
W
138
1290
Ref. No.
THO23200-2
Joist Size
Factored Resistance4
Header Material (100%)
Fastener Schedule2,5,6
Dimensions (in)
Steel Gauge
EWP Hangers
TF
Qty
Type
Qty
Type
5-1/2
11-1/4
3-1/4
11.5
2-1/2
16d
10d
5-9/16
11-1/4
12
3-1/8
15
16d
HLBH55115 GLTV5.511
5-9/16
11-1/2
12
3-1/8
15
16d
BPH55118
-- --
12
5-9/16
11-7/8
2-1/2
--
2-1/32
10
16d
10d
PHM55118
-- --
7/10
5-5/8
11-7/8
2-1/2
16d
10d
5-1/2
11-7/8
3-1/4
11.5
2-1/2
16d
10d
GLTV5.511,
PHXU55118 HB5.50/11.88,
HWU5.50/11.88
HLBH55118 HGLTV5.511
5-9/16
11-7/8
12
MPH55118
WM5.50/11.88
12
5-5/8
11-7/8
2-1/2
PHXU5512
HB5.50/12
5-1/2
12
3-1/4
11.5
15
16d
16d duplex
10d
2-1/2
16d
10d
3-1/8
3-3/4
5-1/4 x 12
HLBH5512
-- --
5-9/16
12
12
3-1/8
15
16d
BPH5514
-- --
12
5-9/16
14
2-1/2
--
2-1/32
10
16d
10d
PHM5514
-- --
7/10
5-5/8
14
2-1/2
16d
10d
5-1/2
14
3-1/4
11.5
2-1/2
16d
10d
5-1/4 x 14
PHXU5514
HLBH5514
BPH5516
PHM5516
5-1/4 x 16
PHXU5516
HLBH5516
BPH5518
GLTV5.514,
HB5.50/14,
HWU5.50/14
5-9/16
14
12
3-1/8
15
16d
-- --
12
5-9/16
16
2-1/2
--
2-1/32
10
16d
10d
-- --
7/10
5-5/8
16
2-1/2
16d
10d
5-1/2
16
3-1/4
11.5
2-1/2
16d
10d
HGLTV5.514
GLTV5.516,
HB5.50/16,
HWU5.50/16
5-9/16
16
12
3-1/8
15
16d
-- --
12
5-9/16
18
2-1/2
--
2-1/32
10
16d
10d
HGLTV5.516
-- --
7/10
5-5/8
18
2-1/2
16d
10d
PHXU5518
GLTV5.518,
HB5.50/18
5-1/2
18
3-1/4
11.5
2-1/2
16d
10d
HLBH5518
HGLTV5.518
5-9/16
18
12
3-1/8
15
16d
PHM5518
5-1/4 x 18
9575
8330
9575
7610
5170
--
1290
--
42.59
37.06
42.59
33.85
23.00
--
5.74
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
---------
15295
68.04
15295
68.04
5300
23.58
5395
24.00
15215
67.68
15215
67.68
5055
22.49
5280
23.49
13825
61.50
13825
61.50
5435
24.18
4435
19.73
13825
61.50
13825
61.50
5055
22.49
4880
21.71
12840
57.12
12840
57.12
4725
21.02
4880
21.71
---------
1770
7.87
1770
8.00
1245
5.54
--1290
LVL
--
kN
DF-L
I-Joist2
Lbs
Unit
SPF
DF-L
LSL
Uplift1
DF-L 115%
5-1/4 x 11-7/8
Joist
-- --
HLBH55112
5-1/4 x 11-1/2
Steel Gauge
Ref. No.
GLTV5.50/11.25,
PHXU55112 HB5.50/11.25,
HWU5.50/11.25
Header
Masonry3
5-1/4 x 11-1/4
USP
Stock No.
Factored Resistance4
Header Material (100%)
Fastener Schedule2,5,6
Dimensions (in)
Lbs
--
9575
8330
9575
7610
5170
--
kN
--
42.59
37.06
42.59
33.85
23.00
--
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
-------------
15295
68.04
--9575
42.59
15295
68.04
5300
23.58
5395
24.00
15215
67.68
--8330
37.06
15215
67.68
5055
22.49
5280
23.49
13825
61.50
--9575
42.59
13825
61.50
5435
24.18
4435
19.73
13825
61.50
--7610
33.85
13825
61.50
5055
22.49
4880
21.71
12840
-57.12
--6165
-27.42
5170
-23.00
-12840
-57.12
-4725
-21.02
-4880
-21.71
--
1770
7.87
--1290
5.74
1770
7.87
1245
5.54
--1290
5.74
Lbs
--
9575
8330
9575
7610
5170
--
kN
--
42.59
37.06
42.59
33.85
23.00
--
5.74
Lbs
kN
Lbs
kN
Lbs
kN
-------
15295
68.04
5300
23.58
5395
24.00
15215
67.68
5055
22.49
5280
23.49
13825
61.50
5435
24.18
4435
19.73
13825
61.50
5055
22.49
4880
21.71
12840
57.12
4725
21.02
4880
21.71
-------
1770
7.87
1245
5.54
--1290
Lbs
--
9575
8330
9575
7610
5170
--
kN
--
42.59
37.06
42.59
33.85
23.00
--
5.74
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
-----------
15295
68.04
5300
23.58
5395
24.00
9575
42.59
15295
68.04
15215
67.68
5055
22.49
5280
23.49
8330
37.06
15215
67.68
13825
61.50
5435
24.18
4435
19.73
9575
42.59
13825
61.50
13825
61.50
5055
22.49
4880
21.71
7610
33.85
13825
61.50
12840
57.12
4725
21.02
4880
21.71
5170
23.00
12840
57.12
-----------
1770
7.87
1265
5.63
--1290
5.74
1770
7.87
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) When I-joist is used as a header, all nails must be 10d x 1-1/2.
3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.
4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
5) Minimum nail embedment shall be 8 nail diameters (typ.).
6) NAILS
!
!
!
!
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
New products or updated product information are designated in red font.
EWP Hangers
Joist Size
continued
PSL
L
TF
H
W
USP2240-131
139
TF
Qty
Type
Qty
Type
5-1/2
20
3-1/4
11.5
2-1/2
16d
10d
HLBH5520
-- --
5-9/16
20
12
3-1/8
15
16d
PHXU71725
-- --
7-1/8
7-1/4
3-1/4
13-1/8
2-1/2
16d
10d
BPH71925
-- --
12
7-1/8
9-1/4
--
2-3/8
10
16d
10d
-- --
7/10
7-1/8
9-1/4
2-1/2
10
16d
10d
7-1/8
9-1/4
3-1/4
13-1/8
2-1/2
16d
10d
-- --
7-1/8
9-1/4
12
3-1/8
15
16d
B7.12/9.5
12
7-1/8
9-1/2
--
2-3/8
10
16d
10d
-- --
7/10
7-1/8
9-1/2
2-1/2
10
16d
10d
7-1/8
9-1/2
3-1/4
13-1/8
2-1/2
16d
10d
BPH7195
PHM3595-2
7 x 9-1/2
PHXU7195
HLBH7195
MPH3595-2
WMI49.5-2
7-1/8
9-1/2
12
3-1/8
15
16d
12
7-1/8
9-1/2
2-1/2
3-3/4
16d duplex
10d
-- --
12
7-1/8
11-1/4
--
2-3/16
10
16d
10d
PHXU71112
GLTV411.25-2,
HB7.12/11.25
7-1/8
11-1/4
3-1/4
13-1/8
2-1/2
16d
10d
HLBH71112
HGLTV411.25-2
7-1/8
11-1/4
12
3-1/8
15
16d
MPH35112-2
WMI411.25-2
12
7-1/8
11-1/4
2-1/2
3-3/4
16d duplex
10d
BPH71118
B7.12/11.88
12
7-1/8
11-7/8
--
2-3/16
10
16d
10d
PHM35118-2
-- --
7/10
7-1/8
11-7/8
2-1/2
10
16d
10d
PHXU71118
GLTV411.88-2,
HB7.12/11.88,
HWU7.12/11.88,
WPI411.88-2
7-1/8
11-7/8
3-1/4
13-1/8
2-1/2
16d
10d
HLBH71118
HGLTV411.88-2
7-1/8
11-7/8
12
3-1/8
15
16d
MPH35118-2
WMI411.88-2
12
7-1/8
11-7/8
2-1/2
3-3/4
16d duplex
10d
BPH7114
B7.12/14
12
7-1/8
14
--
2-3/16
10
16d
10d
-- --
7/10
7-1/8
14
2-1/2
10
16d
10d
7-1/8
14
3-1/4
13-1/8
2-1/2
16d
10d
PHM3514-2
7 x 14
-- --
BPH71112
7 x 11-1/4
7 x 11-7/8
GLTV49.5-2,
HB7.12/9.5,
WPI49.5-2
PHXU7114
GLTV414-2,
HB7.12/14,
WPI414-2
HLBH7114
HGLTV414-2
7-1/8
14
12
3-1/8
15
16d
MPH3514-2
WMI414-2
12
7-1/8
14
2-1/2
3-3/4
16d duplex
10d
DF-L
HLBH71925
LSL
PHXU71925
HB7.12/9.25,
WPI49.25-2
PSL
PHM35925-2
7 x 9-1/4
LVL
7 x 7-1/4
DF-L
I-Joist2
5-1/4 x 20
Unit
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
-------------------
9575
42.59
15295
68.04
9575
42.59
5300
23.58
5395
24.00
9575
42.59
15295
68.04
5300
23.58
5395
24.00
8330
37.06
15215
67.68
8330
37.06
5055
22.49
5280
23.49
8330
37.06
14935
66.44
5055
22.49
5280
23.49
9575
42.59
13825
61.50
9575
42.59
5435
24.18
4435
19.73
9575
42.59
13825
61.50
5435
24.18
4435
19.73
7610
33.85
13825
61.50
7610
33.85
5055
22.49
4880
21.71
7610
33.85
13825
61.50
5055
22.49
4880
21.71
DF-L 115%
Uplift1
Masonry3
Ref. No.
Joist
SPF
HB5.50/20
Header
5170
23.00
12840
57.12
5170
23.00
4725
21.02
4880
21.71
5170
23.00
12840
57.12
4725
21.02
4880
21.71
-------------------
1290
5.74
1770
7.87
1290
5.74
1245
5.54
--1290
5.74
1930
8.59
1245
5.54
--1290
Lbs
--
9575
8330
9575
7610
5170
--
kN
--
42.59
37.06
42.59
33.85
23.00
--
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
-----------------
15295
68.04
--5300
23.58
9575
42.59
15295
68.04
--5300
23.58
5395
24.00
14935
66.44
--5060
22.51
8330
37.06
14935
66.44
--5060
22.51
5280
23.49
13825
61.50
--5435
24.18
9575
42.59
13825
61.50
--5435
24.18
4435
19.73
13825
61.50
--5055
22.49
7610
33.85
13825
61.50
--5055
22.49
4880
21.71
12840
-57.12
--6165
-27.42
4725
-21.02
-5170
-23.00
-12840
-57.12
--6165
-27.42
4725
-21.02
-4880
-21.71
--
1930
8.59
--1245
5.54
1290
5.74
1930
8.59
--1245
5.54
---
Lbs
--
9575
8330
9575
7610
5170
--
1290
--
kN
--
42.59
37.06
42.59
33.85
23.00
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
---------
15295
68.04
--5300
23.58
5395
24.00
14935
66.44
--5060
22.51
5280
23.49
13825
61.50
--5435
24.18
4435
19.73
13825
61.50
--5055
22.49
4880
21.71
12840
-57.12
--6165
-27.42
4725
-21.02
-4880
-21.71
--
1930
8.59
--1245
5.54
---
5.74
1290
Lbs
--
9575
8330
9575
7610
5170
--
kN
--
42.59
37.06
42.59
33.85
23.00
--
Lbs
kN
Lbs
kN
-----
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) When I-joist is used as a header, all nails must be 10d x 1-1/2.
3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.
4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
5) Minimum nail embedment shall be 8 nail diameters (typ.).
6) NAILS
!
!
!
!
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
New products or updated product information are designated in red font.
5.74
1930
8.59
---
L
TF
H
W
140
5.74
PHXU5520
USP
Stock No.
Factored Resistance4
Header Material (100%)
Fastener Schedule2,5,6
Dimensions (in)
Steel Gauge
Joist Size
continued
EWP Hangers
HLBH7116
MPH3516-2
BPH7118
PHM3518-2
7 x 18
PHXU7118
16
--
2-3/16
10
16d
10d
-- --
7/10
7-1/8
16
2-1/2
10
16d
10d
HGLTV416-2
WMI416-2
B7.12/18
-- -GLTV418-2,
HB7.12/18,
HWI418-2
x
x
x
x
x
x
7
7
12
12
7/10
7
7-1/8
7-1/8
7-1/8
7-1/8
7-1/8
7-1/8
Type
Qty
Type
16
16
16
18
18
18
3-1/4
6
2-1/2
3
2-1/2
3-1/4
13-1/8
12
8
-10
13-1/8
2-1/2
3-1/8
3-3/4
2-3/16
3
2-1/2
8
15
2
10
2
8
16d
16d duplex
16d
16d
16d
6
6
2
6
2
6
10d
16d
10d
10d
10d
10d
HGLTV418-2
7-1/8
18
12
3-1/8
15
16d
MPH3518-2
WMI418-2
12
7-1/8
18
2-1/2
3-3/4
16d duplex
10d
BPH7120
B7.12/20
12
7-1/8
20
--
2-3/16
10
16d
10d
-- --
7/10
7-1/8
20
2-1/2
10
16d
10d
7-1/8
20
3-1/4
13-1/8
2-1/2
16d
10d
7 x 20
PHXU7120
HLBH7120
BPH7122
GLTV420-2,
HB7.12/20
-- -B7.12/22
PHXU7122
HWI422-2
HLBH7122
GLTV422-2,
HB7.12/22,
HGLTV7.12/22
x
x
x
x
7
12
7
7
7-1/8
7-1/8
7-1/8
7-1/8
20
22
22
22
6
3
3-1/4
6
12
-13-1/8
12
3-1/8
2-3/16
2-1/2
3-1/8
15
10
8
15
16d
16d
6
6
6
6
16d
10d
10d
16d
Unit
Lbs
--
5300
5060
5435
5055
4725
--
1245
kN
--
23.58
22.51
24.18
22.49
21.02
--
5.54
Lbs
--
5395
5280
4435
4880
4880
--
--
kN
--
24.00
23.49
19.73
21.71
21.71
--
--
Lbs
--
9575
8330
9575
7610
5170
--
1290
37.06
42.59
33.85
LVL
Qty
DF-L 115%
GLTV416-2,
HB7.12/16,
WPI416-2
TF
DF-L
7-1/8
LSL
12
HLBH7118
PHM3520-2
7 x 22
Uplift1
Masonry3
PHXU7116
B7.12/16
Joist
SPF
7 x 16
Ref. No.
Header
DF-L
I-Joist2
PHM3516-2
BPH7116
Steel Gauge
USP
Stock No.
Factored Resistance4
Header Material (100%)
Fastener Schedule2,5,6
Dimensions (in)
kN
--
42.59
23.00
--
5.74
Lbs
--
--
1930
kN
--
68.04
66.44
61.50
61.50
57.12
--
8.59
Lbs
--
--
--
--
--
--
6165
--
kN
--
--
--
--
--
--
27.42
--
Lbs
--
5300
5060
5435
5055
4725
--
1245
kN
--
23.58
22.51
24.18
22.49
21.02
--
5.54
Lbs
--
5395
5280
4435
4880
4880
--
--
kN
--
24.00
23.49
19.73
21.71
21.71
--
--
Lbs
--
9575
8330
9575
7610
5170
--
1290
37.06
42.59
33.85
kN
--
42.59
23.00
--
5.74
Lbs
--
--
1930
kN
--
68.04
66.44
61.50
61.50
57.12
--
8.59
Lbs
--
--
--
--
--
--
6165
--
kN
--
--
--
--
--
--
27.42
--
Lbs
--
5300
5055
5435
5055
4725
--
1245
kN
--
23.58
22.49
24.18
22.49
21.02
--
5.54
Lbs
--
5395
5280
4435
4880
4880
--
--
kN
--
24.00
23.49
19.73
21.71
21.71
--
--
Lbs
--
9575
8330
9575
7610
5170
--
1290
37.06
42.59
33.85
kN
--
42.59
23.00
--
5.74
Lbs
--
--
1930
kN
--
68.04
66.44
61.50
61.50
57.12
--
8.59
Lbs
--
5300
5055
5435
5055
4725
--
1245
kN
--
23.58
22.49
24.18
22.49
21.02
--
5.54
Lbs
--
9575
8330
9575
7610
5170
--
1335
37.06
42.59
33.85
kN
--
42.59
23.00
--
5.94
Lbs
--
--
1930
kN
--
68.04
--
66.44
61.50
61.50
57.12
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) When I-joist is used as a header, all nails must be 10d x 1-1/2.
3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.
4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
5) Minimum nail embedment shall be 8 nail diameters (typ.).
6) NAILS
!
!
!
!
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
8.59
L
TF
H
W
EWP Hangers
Joist Size
continued
PSL
USP2240-131
141
PHXU7124
HLBH7124
HLBH7126
GLTV426-2,
HB7.12/26
PHXU7128
B7.12/28,
HB7.12/28,
HWI428-2
HLBH7128
GLTV428-2,
HB7.12/28
7 x 28
PHXU7130
HWI430-2
HLBH7130
GLTV430-2,
HGLTV430-2
7 x 30
PHXU7132
HWI432-2
HLBH7132
GLTV432-2,
HGLTV432-2
7 x 32
Type
Qty
Type
12
7-1/8
24
--
2-3/16
10
16d
10d
x
x
x
x
x
x
x
x
x
x
7
7
7
7
7
7
7
7
7
7
7-1/8
7-1/8
7-1/8
7-1/8
7-1/8
7-1/8
7-1/8
7-1/8
7-1/8
7-1/8
24
24
26
26
28
28
30
30
32
32
3-1/4 13-1/8
6
12
3-1/4 13-1/8
6
12
3-1/4 13-1/8
6
12
3-1/4 13-1/8
6
12
3-1/4 13-1/8
6
12
2-1/2
3-1/8
2-1/2
3-1/8
2-1/2
3-1/8
2-1/2
3-1/8
2-1/2
3-1/8
8
15
8
15
8
15
8
15
8
15
16d
16d
16d
16d
16d
6
6
6
6
6
6
6
6
6
6
10d
16d
10d
16d
10d
16d
10d
16d
10d
16d
--
5300
5055
5435
5055
4725
--
1245
kN
--
23.58
22.49
24.18
22.49
21.02
--
5.54
Lbs
--
9575
8330
9575
7610
5170
--
1335
kN
--
42.59
37.06
42.59
33.85
23.00
--
5.94
Lbs
--
--
1930
kN
--
68.04
66.44
61.50
61.50
57.12
--
8.59
Lbs
--
9575
8330
9575
7610
5170
--
1335
37.06
42.59
33.85
LVL
Lbs
Unit
SPF
Qty
DF-L
TF
LSL
PSL
kN
--
42.59
23.00
--
5.94
Lbs
--
--
1930
kN
--
68.04
66.44
61.50
61.50
57.12
--
8.59
Lbs
--
9575
8330
9575
7610
5170
--
1335
37.06
42.59
33.85
kN
--
42.59
23.00
--
5.94
Lbs
--
--
1930
kN
--
68.04
66.44
61.50
61.50
57.12
--
8.59
Lbs
--
9575
8330
9575
7610
5170
--
1335
37.06
42.59
33.85
kN
--
42.59
23.00
--
5.94
Lbs
--
--
1930
kN
--
68.04
66.44
61.50
61.50
57.12
--
8.59
Lbs
--
9575
8330
9575
7610
5170
--
1335
37.06
42.59
33.85
kN
--
42.59
23.00
--
5.94
Lbs
--
--
1930
kN
--
68.04
--
8.59
66.44
61.50
61.50
57.12
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) When I-joist is used as a header, all nails must be 10d x 1-1/2.
3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.
4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
5) Minimum nail embedment shall be 8 nail diameters (typ.).
6) NAILS
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
L
TF
H
W
142
1-800-328-5934 www.USPconnectors.com
PHXU7126
7 x 26
HWI424-2
GLTV424-2,
HB7.12/24,
HGLTV7.12/24
B7.12/26,
HB7.12/26,
HWI426-2
Uplift1
DF-L 115%
7 x 24
B7.12/24
Joist
Masonry3
BPH7124
Ref. No.
Header
DF-L
I-Joist2
USP
Stock No.
Factored Resistance4
Header Material (100%)
Fastener Schedule2,5,6
Dimensions (in)
Joist Size
continued
Steel Gauge
EWP Hangers
EWP Hangers
Installation:
Use all specified fasteners. See Product Notes, page 10.
Position connector on top plate. Fasten connector to
outside of top plate with specified nails. Insert rafter into
rafter pocket. Adjust rafter and pocket to correct pitch.
Fasten rafter to connector with specified nails. Installing
the TMP requires driving specified nails through the
opposing slots in the pocket. TMPH installation involves
sliding the fulcrum until it supports the pocket at the
desired pitch and nailing down through the fulcrum base
into the top plate to lock the fulcrum into position.
Plate
Rafter Width
1-1/2
1-3/4
2 or 2-1/8
2-5/16
2-1/2 or 2-5/8
3
3-1/2
USP
Stock No. Ref. No.
TMP2
VPA2
TMP175 VPA25
VPA2.06,
TMP21
VPA2.1
TMP23
VPA35
TMP25
VPA3
TMP31
-- -TMP4
VPA4
D
3 1/2
H
fulcrum
4 11/16
W
L
TMPH
Fastener Schedule2,3
Dimensions (in)
Typical TMP
installation
Typical TMPH
installation
Pitch Range:
TMP 1/12 - 6/12
TMPH 6/12 - 14/12
TMP
Factored Resistance
Rafter
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
Steel
Gauge
18
18
W
1-9/16
1-13/16
L
Qty
5-9/16 6
5-9/16 6
Type
10d
10d
Qty
Type
4 10d x 1-1/2
4 10d x 1-1/2
100%
1425
1655
115%
230
230
100%
6.34
7.36
115%
1.02
1.02
100%
1225
1425
115%
195
195
100%
5.45
6.34
115%
0.87
0.87
18
2-1/8
6-3/8
10d
10d x 1-1/2
1860
230
8.27
1.02
1600
195
7.12
0.87
18
18
18
18
2-3/8
2-11/16
3-1/8
3-9/16
6-3/8
6-3/8
7-5/16
7-5/16
6
6
6
6
10d
10d
10d
10d
4
4
4
4
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
2835
2835
2835
2835
230
230
230
230
12.61
12.61
12.61
12.61
1.02
1.02
1.02
1.02
2440
2440
2440
2440
195
195
195
195
10.85
10.85
10.85
10.85
0.87
0.87
0.87
0.87
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase is allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) NAILS
3,4
Dimensions (in)
Factored Resistance
Fastener Schedule
Rafter2
Plate
DF-L
S-P-F
According to Pitch
USP
Rafter Width Stock No.
Ref. No.
Qty
Type
Qty
Type
1-1/2
TMPH2
VPA2
1-9/16
2-1/2
6-9/16
10
10d
10d x 1-1/2
1-3/4
TMPH175
VPA25
1-13/16
2-3/8
6-9/16
10
10d
10d x 1-1/2
2
or 2-1/8
TMPH21
VPA2.1
2-1/8
2-5/8
7-3/8
10
10d
10d x 1-1/2
2-5/16
TMPH23
VPA35
2-3/8
2-1/2
7-3/8
10
10d
10d x 1-1/2
2-1/2
or 2-5/8
TMPH25
VPA3
2-11/16 2-5/16
7-3/8
10
10d
10d x 1-1/2
TMPH31
-- --
3-1/8
2-11/16 4
8-9/16
10
10d
10d x 1-1/2
3-1/2
TMPH4
VPA4
3-9/16
8-9/16
10
10d
10d x 1-1/2
2-1/2
Unit
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
Lbs
kN
6/12
4595
20.44
4595
20.44
4595
20.44
4595
20.44
4595
20.44
4595
20.44
4595
20.44
7/12
4565
20.31
4565
20.31
4565
20.31
4565
20.31
4565
20.31
4565
20.31
4565
20.31
8/12
4480
19.93
4480
19.93
4480
19.93
4480
19.93
4480
19.93
4480
19.93
4480
19.93
10/12
4090
18.19
4090
18.19
4090
18.19
4090
18.19
4090
18.19
4090
18.19
4090
18.19
According to Pitch
12/12
3485
15.50
3485
15.50
3485
15.50
3485
15.50
3485
15.50
3485
15.50
3485
15.50
Uplift
115%
250
1.11
250
1.11
250
1.11
250
1.11
250
1.11
250
1.11
250
1.11
6/12
3950
17.57
3950
17.57
3950
17.57
3950
17.57
3950
17.57
3950
17.57
3950
17.57
7/12
3925
17.46
3925
17.46
3925
17.46
3925
17.46
3925
17.46
3925
17.46
3925
17.46
8/12
3855
17.15
3855
17.15
3855
17.15
3855
17.15
3855
17.15
3855
17.15
3855
17.15
10/12
3515
15.64
3515
15.64
3515
15.64
3515
15.64
3515
15.64
3515
15.64
3515
15.64
12/12
2995
13.32
2995
13.32
2995
13.32
2995
13.32
2995
13.32
2995
13.32
2995
13.32
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase is allowed.
2) Web stiffeners are required for all Wood I-Joist installations.
3) Minimum nail embedment shall be 8 nail diameters (typ).
4) NAILS
1-800-328-5934 www.USPconnectors.com
USP2240-131
Uplift
115%
215
0.96
215
0.96
215
0.96
215
0.96
215
0.96
215
0.96
215
0.96
143
EWP Hangers
skew
to45
45maximum
maximum
skew to
W2
1-1/2
LSSH15-TZ
1-1/2
1-3/4
LSSH210
LSSH179
2 - 2-1/8
LSSH20
2-1/4 - 2-5/16
2-1/2
2-5/8
3
3-1/2
LSSH23
LSSH25
LSSH26
LSSH31
LSSH35
1-1/2
LSSH15-TZ
1-1/2
1-3/4
LSSH210
LSSH179
2 - 2-1/8
LSSH20
2-1/4 - 2-5/16
2-1/2
2-5/8
3
3-1/2
LSSH23
LSSH25
LSSH26
LSSH31
LSSH35
LSU26, LSU26Z,
LSSU28, LSSU28Z
LSSU210
LSSUI25
LSSUI2.06,
LSSU2.1
LSSUI35
LSSUH310
-- -LSSU210-2
LSSU410
LSU26, LSU26Z,
LSSU28, LSSU28Z
LSSU210
LSSUI25
LSSUI2.06,
LSSU2.1
LSSUI35
LSSUH310
-- -LSSU210-2
LSSU410
W2
W2
W1
Slope to
45 up
or down
LSSH210
Rafter
Slope to
45 up
or down
LSSH35
Factored Resistance
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
Steel
Gauge
W1
W2
18
1-9/16
1-3/4
18
18
1-9/16 1-3/4
1-13/16 1-5/8
18
2-1/8
18
16
16
16
16
2-5/16
2-9/16
2-11/16
3-1/8
3-9/16
2-1/2
18
1-9/16
18
18
1-9/16 1-3/4
1-13/16 1-5/8
5-1/16
6 10d HDG 7
Type
100%
115%
100%
115%
100%
115%
100%
115%
1640
1395
7.30
6.21
1165
865
5.18
3.85
8-13/16 10
8-13/16 10
10d
10d
7
7
10d x 1-1/2
10d x 1-1/2
2775
2775
2005
2005
12.34
12.34
8.92
8.92
1970
1970
1240
1240
8.76
8.76
5.52
5.52
8-13/16 10
10d
10d x 1-1/2
2620
1845
11.65
8.21
1860
1030
8.27
4.58
2620
4260
4260
5230
5230
1845
2250
2250
2985
2985
11.65
18.95
18.95
23.27
23.27
8.21
10.01
10.01
13.28
13.28
1860
3025
3025
3715
3715
1030
1390
1390
1845
1845
8.27
13.46
13.46
16.53
16.53
4.58
6.18
6.18
8.21
8.21
2-3/8 8-13/16 10
10d
7
10d x 1-1/2
2-3/4 8-13/16 18
16d
12
10d x 1-1/2
2-5/8 8-13/16 18
16d
12
10d x 1-1/2
3-3/4 8-13/16 18
16d
12
10d x 1-1/2
3-1/2 8-13/16 18
16d
12
10d x 1-1/2
SKEWED HANGERS or SLOPED & SKEWED HANGERS
1-3/4
5-1/16
6 10d HDG 7
1340
1395
5.96
6.21
950
865
4.23
3.85
8-13/16 10
8-13/16 10
10d
10d
7
7
10d x 1-1/2
10d x 1-1/2
2775
2775
2005
2005
12.34
12.34
8.92
8.92
1970
1970
1240
1240
8.76
8.76
5.52
5.52
18
2-1/8
2-1/2
8-13/16 10
10d
10d x 1-1/2
2620
1845
11.65
8.21
1860
1140
8.27
5.07
18
16
16
16
16
2-5/16
2-9/16
2-11/16
3-1/8
3-9/16
2-3/8
2-3/4
2-5/8
3-3/4
3-1/2
8-13/16
8-13/16
8-13/16
8-13/16
8-13/16
10d
16d
16d
16d
16d
7
12
12
12
12
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
2620
2985
2985
3145
3145
1845
2250
2250
2985
2985
11.65
13.28
13.28
13.99
13.99
8.21
10.01
10.01
13.28
13.28
1860
2120
2120
2235
2235
1140
1390
1390
1845
1845
8.27
9.43
9.43
9.94
9.94
5.07
6.18
6.18
8.21
8.21
10
14
14
14
14
W2
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
2) Minimum nail embedment shall be 8 nail diameters (typ).
3) NAILS:G[QDLOVDUHGLD[ORQJGQDLOVDUHGLD[ORQJGQDLOVDUHGLD[ORQJ
144
Typical LSSH179
installation
Header
Ref. No.
W1
Fastener Schedule2,3
Dimensions (in)
USP
Stock No.
1-800-328-5934 www.USPconnectors.com
Rafter
Width
3&4
Installation:
Use all specified fasteners. See Product Notes, page 10.
WS structural screws supplied with connector.
Substituting with lag screws will reduce capacity.
Beams comprised of multiple plies must be laminated
to act as a single member.
Multi-ply carrying beams may require additional connection
of laminations at connector.
H1
NEW
EWP Hangers
LGU, MGU, and HGUs are high capacity girder to girder face mount
connectors. Fastening is by WS structural screws for ease of
installation. Fastenings are placed high on the connector to permit the
connection of a deep carried member to a shallower carrying member.
Very useful where tops of beams must be flush.
Fastener Schedule3
Header
Beam
Width
3-1/8
3-1/2
5-1/8
5-1/4
5-1/2
6-3/4
7
8-3/4
USP
Stock No.
LGU325
LGU363
MGU363
HGU363
LGU525
MGU525
HGU525
MGU550
HGU550
MGU562
HGU562
MGU700
HGU700
HGU725
HGU900
Ref. No.
LGU3.25-SDS
LGU3.63-SDS
MGU3.63-SDS
HGU3.63-SDS
LGU5.25-SDS
MGU5.25-SDS
HGU5.25-SDS
MGU5.50-SDS
HGU5.50-SDS
MGU5.62-SDS
HGU5.62-SDS
MGU7.00-SDS
HGU7.00-SDS
HGU7.25-SDS
HGU9.00-SDS
Steel
Gauge
10
10
10
7
10
10
7
10
7
10
7
10
7
7
7
Truss
H
(min)
8
8
9-1/4
11
8
9-1/4
11
9-1/4
11
9-1/4
11
9-1/4
11
11
11
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
W
3-1/4
3-5/8
3-5/8
3-5/8
5-1/4
5-1/4
5-1/4
5-1/2
5-1/2
5-5/8
5-5/8
7
7
7-1/4
9
Factored Resistance
DF-L (Lbs)
H1
7-3/8
7-3/8
8-5/8
10-3/8
7-3/8
8-5/8
10-3/8
8-5/8
10-3/8
8-5/8
10-3/8
8-5/8
10-3/8
10-3/8
10-3/8
D
4-1/2
4-1/2
4-1/2
5-1/4
4-1/2
4-1/2
5-1/4
4-1/2
5-1/4
4-1/2
5-1/4
4-1/2
5-1/4
5-1/4
5-1/4
100%
10760
10760
17465
24285
10760
17465
24285
17465
24285
17465
24285
17465
24285
24285
24285
115%
7835
7835
9605
13630
7835
9605
13630
9605
13630
9605
13630
9605
13630
13630
13630
100%
47.86
47.86
77.69
108.03
47.86
77.69
108.03
77.69
108.03
77.69
108.03
77.69
108.03
108.03
108.03
115%
34.85
34.85
42.73
60.63
34.85
42.73
60.63
42.73
60.63
42.73
60.63
42.73
60.63
60.63
60.63
100%
7640
7640
12400
17245
7640
12400
17245
12400
17245
12400
17245
12400
17245
17245
17245
115%
5565
5565
6820
9675
5565
6820
9675
6820
9675
6820
9675
6820
9675
9675
9675
100%
33.99
33.99
55.16
76.71
33.99
55.16
76.71
55.16
76.71
55.16
76.71
55.16
76.71
76.71
76.71
115%
24.76
24.76
30.34
43.04
24.76
30.34
43.04
30.34
43.04
30.34
43.04
30.34
43.04
43.04
43.04
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) "Specify" denotes the required supported beam height that must be specified at the time of ordering.
3) WS3 Wood Screws are 1/4" x 3" long and are included in hangers.
New products or updated product information are designated in red font.
Specialty Options Chart refer to Specialty Options pages 210 to 211 for additional details.
Option
Range
USP Series
LGU
MGU
HGU
LGU
Factored
Resistance
MGU
HGU
Ordering
LGU
MGU
HGU
Skewed1
Inverted Flange
One Inverted-Flange option
available on some sizes. See
footnotes 2 and 3.
1) Skewed hangers with skews greater than 15 may have all joist fasteners on outside flange.
2) One inverted-flange (1IF) is available on the following sizes.
LGU363, LGU525
MGU525, MGU550, MGU563, MGU700
HGU525, HGU550, HGU562,HGU700, HGU725, HGU900
3) The inverted flange option is not available on skewed LGU, MGU or HGU hangers.
1-800-328-5934 www.USPconnectors.com
USP2240-131
145
EWP Hangers
2 1/8
Installation:
Use all specified fasteners. See Product Notes, page 10.
Dimensions (in)
Header
Glulam
Size
3-1/8 x 6
3-1/8 x 7-1/2
3-1/8 x 9
3-1/8 x 10-1/2
3-1/8 x 12
3-1/8 x 13-1/2
3-1/8 x 15
3-1/8 x 16-1/2
3-1/8 x 18
3-1/4 x 9
3-1/4 x 12
5-1/8 x 6
5-1/8 x 7-1/2
5-1/8 x 9
5-1/8 x 10-1/2
5-1/8 x 12
5-1/8 x 13-1/2
5-1/8 x 15
5-1/8 x 16-1/2
5-1/8 x 18
5-1/8 x 19-1/2
5-1/8 x 21
5-1/8 x 24
5-1/4 x 9
5-1/4 x 12
6-3/4 x 6
6-3/4 x 7-1/2
6-3/4 x 9
6-3/4 x 10-1/2
6-3/4 x 12
6-3/4 x 13-1/2
6-3/4 x 15
6-3/4 x 16-1/2
6-3/4 x 18
6-3/4 x 19-1/2
6-3/4 x 21
6-3/4 x 22-1/2
6-3/4 x 24
USP
Stock No.
GHF31600
GHF31750
GHF31900
GHF31105
GHF31120
GHF31135
GHF31150
GHF31165
GHF31178
GHF32900
GHF32120
GHF51600
GHF51750
GHF51900
GHF51105
GHF51120
GHF51135
GHF51150
GHF51165
GHF51178
GHF51192
GHF51205
GHF51233
GHF52900
GHF52120
GHF67600
GHF67750
GHF67900
GHF67105
GHF67120
GHF67135
GHF67150
GHF67165
GHF67180
GHF67195
GHF67210
GHF67225
GHF67240
Steel
Ref. No. Gauge
W
-- -12
3-3/16
-- -12
3-3/16
-- -12
3-3/16
-- -12
3-3/16
-- -12
3-3/16
-- -12
3-3/16
-- -12
3-3/16
-- -12
3-3/16
-- -12
3-3/16
-- -12
3-5/16
-- -12
3-5/16
-- -12
5-3/16
-- -12
5-3/16
-- -12
5-3/16
-- -12
5-3/16
-- -12
5-3/16
-- -7
5-3/16
-- -7
5-3/16
-- -7
5-3/16
-- -7
5-3/16
-- -7
5-3/16
-- -7
5-3/16
-- -7
5-3/16
-- -12
5-5/16
-- -12
5-5/16
-- -12
6-7/8
-- -12
6-7/8
-- -12
6-7/8
-- -12
6-7/8
-- -7
6-7/8
-- -7
6-7/8
-- -7
6-7/8
-- -7
6-7/8
-- -7
6-7/8
-- -7
6-7/8
-- -7
6-7/8
-- -7
6-7/8
-- -7
6-7/8
Fastener Schedule
Joist
Factored Resistance
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
D
2-3/8
2-3/8
2-3/8
2-3/8
2-3/8
2-3/4
2-3/4
2-3/4
2-3/4
2-3/8
2-3/8
2-3/8
2-3/8
2-3/8
2-3/8
2-3/8
2-3/8
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
2-3/8
2-3/8
2-3/8
2-3/8
2-3/8
2-3/8
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
3
3
3
3
Qty
10
12
16
20
22
24
26
28
30
16
22
10
14
18
22
24
26
28
30
32
34
36
40
18
24
12
16
20
24
28
30
32
34
36
40
44
46
48
100%
14.03
16.84
22.44
28.05
30.87
33.65
36.48
39.26
42.08
22.44
30.87
14.03
19.64
25.24
30.87
33.65
41.64
44.84
48.04
51.25
54.45
57.65
64.06
25.24
33.65
16.84
22.44
28.05
33.65
44.84
48.04
51.25
54.45
57.65
64.06
70.46
73.67
76.87
115%
6.45
6.45
8.05
9.68
9.68
9.68
11.30
14.52
17.75
9.68
9.68
6.45
6.45
8.05
9.68
9.68
11.05
12.90
12.90
14.72
14.72
16.57
20.26
8.05
9.68
6.45
8.05
9.68
12.92
14.72
14.72
18.42
18.42
22.11
25.78
33.14
36.83
40.52
100% 115%
2650 1220
3180 1220
4240 1520
5295 1825
5830 1825
6355 1825
6890 2135
7415 2745
7945 3350
4240 1825
5830 1825
2650 1220
3710 1220
4765 1520
5830 1825
6355 1825
7860 2085
8465 2435
9070 2435
9675 2780
10280 2780
10885 3130
12095 3825
4765 1520
6355 1825
3180 1220
4240 1520
5295 1825
6355 2440
8465 2780
9070 2780
9675 3480
10280 3480
10885 4175
12095 4870
13305 6260
13910 6955
14515 7650
100%
11.79
14.15
18.86
23.55
25.93
28.27
30.65
32.98
35.34
18.86
25.93
11.79
16.50
21.20
25.93
28.27
34.96
37.66
40.35
43.04
45.73
48.42
53.80
21.20
28.27
14.15
18.86
23.55
28.27
37.66
40.35
43.04
45.73
48.42
53.80
59.19
61.88
64.57
115%
5.43
5.43
6.76
8.12
8.12
8.12
9.50
12.21
14.90
8.12
8.12
5.43
5.43
6.76
8.12
8.12
9.27
10.83
10.83
12.37
12.37
13.92
17.02
6.76
8.12
5.43
6.76
8.12
10.85
12.37
12.37
15.48
15.48
18.57
21.66
27.85
30.94
34.03
1) Factored resistances based on seat bearing calculated at 560 psi perpendicular to grain.
!
3) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
New products or updated product information are designated in red font.
Specialty Options Chart refer to Specialty Options pages 210 to 211 for additional details.
Option
Range
Factored
Resistance
Ordering
Skewed1,3
81,
8
,#1)"),!
,#2-)),!,+0("40
$/"1"/1%+
8
!!SK, +$)"/".2&/"!+!/&$%1(R)
,/)"#1(L), 1,-/,!2 1+2*"/
5
Sloped Seat2
81,
8
,#1)"),!
!!SL, 0),-"/".2&/"!+!
2-(U) ,/!,4+(D),
1,-/,!2 1+2*"/
5
Sloped / Skewed1,2
""),-"!"1+!("4"!
,#1)"),!
,+0("40$/"1"/
,#2-)),!1%+
8
Inverted Flange
,13&))"&+4&!1%0)"001%+
9
,#1)"),!
,#1)"),!4%"++&)&+$
&+1,1%"02--,/1*"*"/0"+!$/&+
""),-"!"1+!("4"!
5
("4"!%+$"/04&1%0("40$/"1"/1%+
7*6%3"))',&01+&)&+$,+,210&!"#)+$"
),-"!,/0),-"!0("4"!%+$"/04&1%0),-"0$/"1"/1%+
7*6%3"!!&1&,+)',&01+&)0
))0("4"!%+$"/0/".2&/"',&011,""3")*&1"/ 21
146
1-800-328-5934 www.USPconnectors.com
Typical
GHF51135IF
inverted flange
installation
Typical GHF51135
installation
GHF
L
TF
3
3
TH
4
Dimensions (in)
4
4
11 1/4
H
3
3
KMEG5
KEG5
Fastener Schedule
Factored Resistance
Joist
Bolt
Bolt
Qty Dia. Qty Dia.
TF
3-1/4 specify
2-1/2
12
3/4
3/4
KLEG5
LEG5
5-1/4 specify
2-1/2
12
3/4
3/4
KMEG5
MEG5
5-1/4 specify
2-1/2
12
3/4
3/4
KEG5
EG5
1/4
5-1/4 specify
2-1/2
12
KLEG7
LEG7
6-7/8 specify
2-1/2
12
3/4
3/4
KMEG7
MEG7
6-7/8 specify
2-1/2
12
3/4
3/4
KEG7
EG7
1/4
6-7/8 specify
2-1/2 13-1/2 8
8-3/4
KEG9
EG9
1/4
8-7/8 specify
2-1/2 15-1/2 8
10-3/4
KEG11
-- --
1/4
10-7/8 specify
2-1/2 17-1/2 8
6-3/4
17 1/2
H
LEG3
5-1/8
KLEG3
3-1/8
Header
3
TF
Installation:
Use all specified fasteners. See Product Notes,
page 10.
Bolts are not supplied unless ordered separately.
Bolts provided by other suppliers must meet or
exceed ASTM A 307 Grade A, or ASME SAE Grade 2,
or better.
Minimum header height is 10 for the KLEG;
13 for the KMEG; 20 for the KEG.
UBeam
USP
Top
Width Stock No. Ref. No Flange Strap
Typical KLEG5
installation
KLEG3
Steel Gauge
8 1/4
H
See chart
USPprimer
See Specialty Options Chart.
Load values are derived from data
submitted to various North American
building code evaluators.
EWP Hangers
DF-L
Application
With Top Flange
Without Top Flange
With Top Flange
Without Top Flange
With Top Flange
Without Top Flange
With Top Flange
Without Top Flange
With Top Flange
Without Top Flange
With Top Flange
Without Top Flange
With Top Flange
Without Top Flange
With Top Flange
Without Top Flange
With Top Flange
Without Top Flange
S-P-F
Vertical 100%
Uplift 115%2
Vertical 100%
Uplift 115%2
Lbs
15060
5125
15060
5125
17555
7620
23125
13190
15060
5125
17555
7620
24410
13235
26100
13270
27785
13300
Lbs
4040
4040
5910
5910
5915
5915
7625
7625
5910
5910
5910
5910
9595
9595
9580
9580
9570
9570
Lbs
12950
4410
12950
4410
15095
6555
19890
11345
12950
4410
15095
6555
20995
11380
22445
11410
23895
11440
Lbs
3475
3475
5085
5085
5085
5085
6560
6560
5085
5085
5085
5085
8250
8250
8240
8240
8230
8230
kN
66.99
22.80
66.99
22.80
78.09
33.90
102.87
58.67
66.99
22.80
78.09
33.90
108.59
58.87
116.10
59.03
123.60
59.16
kN
17.97
17.97
26.29
26.29
26.31
26.31
33.92
33.92
26.29
26.29
26.29
26.29
42.68
42.68
42.62
42.62
42.57
42.57
kN
57.61
19.62
57.61
19.62
67.15
29.16
88.48
50.47
57.61
19.62
67.15
29.16
93.39
50.62
99.84
50.76
106.29
50.89
kN
15.46
15.46
22.62
22.62
22.62
22.62
29.18
29.18
22.62
22.62
22.62
22.62
36.70
36.70
36.65
36.65
36.61
36.61
1) Factored resistances are for a supporting member with a width of 5-1/2", and 460 psi perpendicular to grain loading in single shear.
2) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
3) "Specify" denotes the required supported beam height that must be specified at the time of ordering.
Specialty Options Chart refer to Specialty Options pages 210 and 212 for additional details.
Option
Skewed3
Sloped Seat
Range
Factored
Resistance
Ordering
KMEG - 8160 lbs. Max.
Add OS, and
right (R) or left (L),
to product number.
Ex. KLEG3H112-OSL
1-800-328-5934 www.USPconnectors.com
USP2240-131
147
EWP Hangers
2 1/2
Installation:
Use all specified fasteners. See Product Notes, page 10.
Minimum height (H) is 71/2.
Beam
USP
Width Stock No.
KHHB3
3-1/8
KGB3
KHHB5
5-1/8 KGB5
KHGB5
KHHB7
6-3/4 KGB7
KHGB7
Steel
Ref. No. Gauge
HHB3
7
GB3
7
HHB5
7
GB5
7
HGB5
7
HHB7
7
GB7
7
HGB7
7
KHHB
5
Fastener Schedule
Header4
Factored Resistance
Joist
H
specify
specify
specify
specify
specify
specify
specify
specify
D
3
3-1/2
3
3-1/2
4
3
3-1/2
4
Qty
4
4
4
4
4
4
4
4
Qty
6
10
6
10
12
6
10
12
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
Top Face
W
3-1/4
3-1/4
5-1/4
5-1/4
5-1/4
6-7/8
6-7/8
6-7/8
Type
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
Qty
6
6
6
6
6
6
6
6
Type
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
100%
7035
9300
7035
9300
10845
7035
9300
10845
115%
2525
2525
2525
2525
2525
2525
2525
2525
100%
31.29
41.37
31.29
41.37
48.24
31.29
41.37
48.24
115%
11.23
11.23
11.23
11.23
11.23
11.23
11.23
11.23
100%
5910
7810
5910
7810
9110
5910
7810
9110
115%
2120
2120
2120
2120
2120
2120
2120
2120
100%
26.29
34.74
26.29
34.74
40.52
26.29
34.74
40.52
115%
9.43
9.43
9.43
9.43
9.43
9.43
9.43
9.43
148
1-800-328-5934 www.USPconnectors.com
Materials: 7 gauge
Finish: USPprimer
Codes: Load values are derived from data
submitted to various North American
building code evaluators.
EWP Hangers
These heavy beam hangers are designed for use with glulam
and timber beams. The continuous top mount flange offers high
load capacity with minimal nailing.
KGLT Medium-duty hanger.
L
2 1/2
Installation:
Use all specified fasteners. See Product Notes, page 10.
W
3-1/4
3-5/8
5-1/4
5-5/8
6-7/8
8-7/8
3-1/4
3-5/8
5-1/4
5-3/8
5-5/8
6-7/8
8-7/8
10-7/8
H
specify
specify
specify
specify
specify
specify
specify
specify
specify
specify
specify
specify
specify
specify
L
10
10
10
10
12
14
12
12
12
12
12
12
14
16
Qty
4
4
4
4
4
4
6
6
6
6
6
6
6
6
Qty
6
6
6
6
6
6
12
12
12
12
12
12
12
12
Factored Resistance2,5
FC^ = 625 psi
Uplift1
DF-L (100%) S-P-F (100%) DF-L (100%) S-P-F (100%) DF-L (115%) S-P-F (115%)
Top Face
Ref. No.
GLT3
GLT4, GLTV4
GLT5, GLTV5
GLT6, GLTV6
GLT7, GLTV7.12
-- -HGLT3
HGLT4, HGLTV4
HGLT5, HGLTV5
HGLTV5.37
HGLT6, HGLTV6
HGLT7, HGLTV7.12
HGLT9, HGLTV9
-- --
KGLT
Fastener Schedule4
Joist
KHGLT
Header
USP
Stock No.
KGLT3
KGLT4
KGLT5
KGLT6
KGLT7
KGLT9
KHGLT3
KHGLT4
KHGLT5
KHGLT537
KHGLT6
KHGLT7
KHGLT9
KHGLT11
2 1/2
6 3/4
Beam
Width
3-1/8
3-1/2
5-1/8
5-1/2
6-3/4
8-3/4
3-1/8
3-1/2
5-1/8
5-5/16
5-1/2
6-3/4
8-3/4
10-3/4
3 1/2
Type
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
Qty
8
8
8
8
8
8
6
6
6
6
6
6
6
6
Type
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
Lbs
10865
10865
10865
10865
10865
10865
14615
15105
15105
15105
15105
15105
16760
18420
kN
48.33
48.33
48.33
48.33
48.33
48.33
65.01
67.19
67.19
67.19
67.19
67.19
74.56
81.94
Lbs
9125
9125
9125
9125
9125
9125
12275
12690
12690
12690
12690
12690
14080
15475
kN
40.59
40.59
40.59
40.59
40.59
40.59
54.60
56.45
56.45
56.45
56.45
56.45
62.63
68.84
Lbs
------------18670
18670
18670
18670
18670
18670
19295
19295
kN
------------83.05
83.05
83.05
83.05
83.05
83.05
85.83
85.83
Lbs
------------15685
15685
15685
15685
15685
15685
16210
16210
kN
------------69.77
69.77
69.77
69.77
69.77
69.77
72.11
72.11
Lbs
2970
2970
2970
2970
2970
2970
2525
2525
2525
2525
2525
2525
2525
2525
kN
13.21
13.21
13.21
13.21
13.21
13.21
11.23
11.23
11.23
11.23
11.23
11.23
11.23
11.23
Lbs
2495
2495
2495
2495
2495
2495
2120
2120
2120
2120
2120
2120
2120
2120
kN
11.10
11.10
11.10
11.10
11.10
11.10
9.43
9.43
9.43
9.43
9.43
9.43
9.43
9.43
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) KGLT load values based on 460 psi perpendicular to grain loading. KHGLT load values based on 460 psi or 625 psi perpendicular to grain loading.
3) "Specify" denotes the required supported beam height that must be specified at time of ordering, withbeing the minimum.
5) No further increase for duration of load allowed.
New products or updated product information are designated in red font.
Specialty Options Chart refer to Specialty Options pages 210 and 212 for additional details.
Option
Range
Skewed1,3
92-
9
Sloped Seat2,3
92-
9
Sloped / Skewed1,2,3
##*-.#"#2,")#5#"
Factored
Resistance
-$3.*'$24*3#-,
1)#5%0#2#02&,
9
* 16
* 16
-$3.*'$24*3#-,
1)#5%0#2#02&,
9
#"3!#2 *#
4*3#131',%
120'%&2*',#',2#0.-*2'-,
Ordering
""SK, ,%*#0#/3'0#"
,"0'%&2(R) -0*#$2(L),
2-.0-"3!2,3+ #0
6
""SL, 1*-.#0#/3'0#"
,"3.(U) -0"-5,(D),
2-.0-"3!2,3+ #0
6
##*-.#"#2,")#5#"
6
""SF, ,%*#0#/3'0#"
,"0'%&2(R) -0*#$2(L),
2-.0-"3!2,3+ #0
6
Saddle
-$2 *#4*3#
.#01'"#
""SA, ,"1""*#
5'"2&0#/3'0#"
2-.0-"3!2,3+ #0
6
:
)#5#"&,%#015'2&1)#51%0#2#02&,
8+7&4#**(-'12,'*',%-,-321'"#$*,%#
*-.#"-01*-.#"1)#5#"&,%#015'2&1*-.#1%0#2#02&,
8+7&4#""'2'-,*(-'12,'*1
**1*-.#"1)#5#"-0!-+ ',2'-,10#/3'0# #4#*!32-,(-'12',**..*'!2'-,1
*-.#"2-.$*,%#15'2&1*-.#1%0#2#02&,
8+7&4#""'2'-,*&#"#0,'*1
1-800-328-5934 www.USPconnectors.com
USP2240-131
149
EWP Hangers
KGLS
TF
Installation:
Use all specified fasteners. See Product Notes, page 10.
Loads and nail schedule apply to each saddle hanger stirrup.
Minimum header height is 81 2 for the KGLS; 81 2 for the KGLST;
101 2 for the KHGLS, and 101 2 for the KHGLST.
KGLST and KHGLST models include seismic straps which must be
installed with (3) 34 thru-bolts in each supported member and (2) 34
thru-bolts into the supporting beams.
Typical KHGLST35
installation
H
W
D
KHGLST
Dimensions (in)
Supported
USP
Glulam
Beam Size Stock No.
KGLS35
KGLST35
KGLS37
3-1/8
KGLST37
KGLS39
KGLST39
KGLS55
KGLST55
KGLS57
5-1/8
KGLST57
KHGLS5
KHGLST5
KGLS77
KGLST77
KGLS79
6-3/4
KGLST79
KHGLS7
KHGLST7
KHGLS9
8-3/4
KHGLST9
Header
Ref. No.
GLS3-5
-- -GLS3-7
-- -GLS3-9
-- -GLS5-5
-- -GLS5-7
-- -HGLS5
-- -GLS7-7
-- -GLS7-9
-- -HGLS7
-- -HGLS9
-- --
W
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
5-1/4
5-1/4
5-1/4
5-1/4
5-1/4
5-1/4
6-7/8
6-7/8
6-7/8
6-7/8
6-7/8
6-7/8
8-7/8
8-7/8
H7
specify
specify
specify
specify
specify
specify
specify
specify
specify
specify
specify
specify
specify
specify
specify
specify
specify
specify
specify
specify
D
5
6-1/2
5
6-1/2
5
6-1/2
5
6-1/2
5
6-1/2
6-1/2
6
5
6-1/2
5
6-1/2
6
6-1/2
6
6-1/2
L
6
10
6
10
6
10
9
12
9
12
12
12
12
12
12
12
12
14
12
16
Factored Resistance2,6
Fastener Schedule
Wood Screws2,5
TF
5-1/4
5-1/4
6-7/8
6-7/8
8-7/8
8-7/8
5-1/4
5-1/4
6-7/8
6-7/8
specify
specify
6-7/8
6-7/8
8-7/8
8-7/8
specify
specify
specify
specify
Qty
6
6
6
6
6
6
6
6
6
6
14
14
6
6
6
6
14
14
14
14
Joist
Bolts
Header
DF-L (Lbs)
DF-L (kN)
S-P-F (Lbs)
S-P-F (kN)
Joist
100%
14795
18575
14795
18575
14795
18575
21180
27380
22860
29060
29785
27720
29410
35245
29410
37575
30220
34250
30220
38280
115%
2525
2525
2525
2525
2525
2525
2525
2525
2525
2525
3365
3365
2525
2525
2525
2525
3365
3365
3365
3365
100%
65.81
82.63
65.81
82.63
65.81
82.63
94.22
121.80
101.69
129.27
132.50
123.31
130.83
156.78
130.83
167.15
134.43
152.36
134.43
170.28
115%
11.23
11.23
11.23
11.23
11.23
11.23
11.23
11.23
11.23
11.23
14.97
14.97
11.23
11.23
11.23
11.23
14.97
14.97
14.97
14.97
100%
12430
15605
12430
15605
12430
15605
17790
23000
19200
24410
25020
23285
24705
29605
24705
31565
25385
28770
25385
32155
115%
2120
2120
2120
2120
2120
2120
2120
2120
2120
2120
2825
2825
2120
2120
2120
2120
2825
2825
2825
2825
100%
55.29
69.42
55.29
69.42
55.29
69.42
79.14
102.31
85.41
108.59
111.30
103.58
109.90
131.69
109.90
140.41
112.92
127.98
112.92
143.04
115%
9.43
9.43
9.43
9.43
9.43
9.43
9.43
9.43
9.43
9.43
12.57
12.57
9.43
9.43
9.43
9.43
12.57
12.57
12.57
12.57
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) Factored resistances and fastener schedules apply to each side of the saddled hanger.
%"$#(!"$
(!"$
4) Hangers with seismic straps may require a minimum joist depth. Consult USP for additional information.
!!"&#"
(' (! " %&$ "#
See Welded Installation
6) The bearing loads are based on 560 psi.
chart on page 213
7) "Specify" denotes the required supported beam height that must be specified at time of ordering.
KGLS & KHGLS Specialty Options Chart refer to Specialty Options pages 210 and 212 for additional details.
Option
Range
Factored
Resistance
Ordering
150
Skewed1
:3. :
+!2 7
+!2 7
.%4/+(%35 +4$
.-2*$62&1$ 3$13' -
9
##SK, -&+$1$04(1$#
-#1(&'3(R) .1+$%3(L),
3./1.#4"3-4,!$1
7
Sloped Seat2
:3. :
Sloped / Skewed1,2
$$+./$#$ 3 -#*$6$#
+!2 7
+!2 7
+!2 7
KHGLS - may not
be sloped/skewed.
$#4"$3 !+$
5 +4$242(-&
231 (&'3+(-$(-3$1/.+ 3(.-
##SL, 2+./$1$04(1$#
## -&+$1$04(1$#
-#4/(U) .1#.6-(D),
$$+./$#$ 3 -#*$6$#
-#1(&'3.1+$%3
3./1.#4"3-4,!$1
7
3./1.#4"3-4,!$1
7
7
*$6$#' -&$126(3'2*$62&1$ 3$13' -
9, 8' 5$ ++).(23- (+(-&.-.432(#$%+ -&$
+./$#.12+./$#2*$6$#' -&$126(3'2+./$2&1$ 3$13' -
9, 8' 5$ ##(3(.- +).(23- (+2
+./$#3./%+ -&$26(3'&1$ 3$13' -
9, 8' 5$ ##(3(.- +'$ #$1- (+2
1-800-328-5934 www.USPconnectors.com
Saddle
;,(-(,4,2 ##+$
;
NOP
LPTA
RFUS
RUSC
LUGT
MUGT15
LPTA
Low profile truss anchors provide uplift and lateral
load resistance.
HUGT
SHA
Hurricane Gusset
Angles . . . . . . . . . . . . . . . . . . . . . . .Page 158
HGA Series
Connects gable trusses to top plates.
HGA
Hurricane Retro-Fit
Connector . . . . . . . . . . . . . . . . . . .Page 159
RT16M
Retrofit connector for trusses installed on top plates.
RT16M
RT15
1-800-328-5934 www.USPconnectors.com
RT7
HCPRS
HHCP2
USP2240-131
LFTA6
151
NOP1
NOP4
Installation:
Use all specified fasteners. See Product Notes,
page 10.
Pre-attach to truss bottom chord or rafter using
prepunched prongs and/or 6d common nails to
prevent wood-to-concrete contact.
Typical NOP4
installation
NOP2X
W
USP
Size Stock No.
NOP2X
2x
NOP1
4x
NOP4
Fastener Schedule1,2
Dimensions
Steel
Gauge W
Ref. No.
TSS2, TBP8
26 1-7/16
-- -22
1-1/2
TSS2-2
26
3-1/2
L
8
8
8
Qty
-- -2
2
Type
-- -6d
6d
NOP4
F1
Uplift
F2
Installation:
Use all specified fasteners. See Product Notes, page 10.
Embed LPTA 4 into concrete tie beam or masonry bond
beam.
Anchors should be spaced no closer than 8 centre-to-centre.
Moisture barrier may be required.
W
Dimensions (in) Fastener Schedule
USP
Steel
Stock No. Ref. No. Gauge
LPTA
LTA2
18
W
5
H
8-1/4
Min
Qty2
10
DF-L (kN)
S-P-F (Lbs)
Uplift F1
F2 Uplift F1
F2 Uplift F1
F2 Uplift F1
F2
10d x 1-1/2 1555 1005 1865 6.92 4.47 8.30 1555 1005 1865 6.92 4.47 8.30
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other
load durations in accordance with the code.
2) Minimum quantity of fasteners to be installed. Product may have additional nail holes not needed to meet
published factored resistance of product.
3) Minimum nail embedment shall be 8 nail diameters (typ).
4) NAILS
152
S-P-F (kN)
3,4
Type
1-800-328-5934 www.USPconnectors.com
1 3/4
1 7/16
LPTA
Installation:
Always install in pairs.
Use all specified fasteners. See Product Notes, page 10.
Designer shall be responsible for design of masonry structure, including
any required reinforcement.
For 1 ply applications, add filler block. Refer to page 182 for wood filler
block installation.
Moisture barrier may be required.
Fastener Schedule3,5
USP
Steel
Stock No. Ref. No. Gauge
RFUS
FGTR
10
No. of
Plys6
2 Ply >
Rafter/Truss7
Qty
12
Qty
4
Concrete/Masonry2,4
Type
WS3
Typical RFUS
installation
DF-L
Type
868$#&$-*21
Lbs
5 1/2
Materials: 10 gauge
Finish: USP primer
Codes: Load values are derived from data submitted to various North
American building code evaluators.
S-P-F
kN
25.31
Lbs
4780
kN
30 1/2
"2-0$#3.*(%20$1(12 ,"$1' 4$!$$,(,"0$ 1$#%-01'-022$0+*- #113"' 15(,# ,#$ 02'/3 )$
0$#3"$%-0-2'$0*- ##30 2(-,1(, ""-0# ,"$5(2'2'$"-#$
1$-5$01 12$,$01
868$#&$-*21-0$/3 *(,12 **$#(, ""-0# ,"$5(2'+ ,3% "230$011.$"(%(" 2(-,1
12$,$011' **!$(,12 **$#2-%3**7&0-32$# ,#0$(,%-0"$#"-,"0$2$+ 1-,07-00$(,%-0"$#"-,"0$2$%"
RFUS
Installation:
Use all specified fasteners. See Product Notes, page 10.
The RUSC should be installed in pairs.
Install on minimum 2 ply with equal wall studs centred directly below.
Works with 2 x 4 bottom chord member and 2 x 4 wall studs.
Typical RUSC
installation
7
3 1/2
Fastener Schedule3,4
No, of
USP
Steel
Stock No. Ref. No. Gauge
Plies5
RUSC
-- -10 2 Ply or greater
Rafter/Truss
Qty
16
Type
WS3
Stud
Qty
16
Type
WS3
DF-L
Lbs
6250
S-P-F
kN
27.80
Lbs
5410
22 3/4
kN
24.07
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake;
no further increase is allowed.
2) Designer must specify stud or post to resist published load values.
4) Fastener schedule is for two straps used together. The RUSC shall be installed in pairs with a
minimum 2 ply truss and wall stud attachment.
5) Truss plies shall be fastened together to act as a unit.
3 1/8
3 1/8
1-800-328-5934 www.USPconnectors.com
RUSC
USP2240-131
153
Uplift
F1
F2
F1
F2
Typical LUGT1
installation
Typical LUGT4
masonry installation
(LUGT3 similar)
Typical LUGT2
masonry installation
Typical LUGTC2
installation
3 1/4
3 3/16
12 7/8
14 13/16
3"
LUGTC2
LUGT1
LUGT2
3,7,8,9,10
USP
Stock No.
154
Ref. No.
Fastener Schedule
Steel
Gauge
No.
of
Plies
Qty
Type
Qty
Type
Qty
Type
F1
F2
Uplift
8d x 1-1/2
Rafter/Truss
4,5,6
Plate
DF-L (Lbs)
Stud
LUGT4
LUGT3
DF-L (kN)
F1
1,2
S-P-F (Lbs)
S-P-F (kN)
F2
Uplift
F1
F2
Uplift
F1
425
1455 4.00
F2
Uplift
1.89
6.47
LUGT1
H10S
16
8d x 1-1/2
8d x 1-1/2
1045
495
1580 4.65
2.20
7.03
900
LUGT2
LUGTC2
LUGT3
LUGT4
LGT2
-- -LGT3-SDS2.5
LGT4-SDS3
14
14
12
12
2
2
3
4
16
16
12
16
10d
10d
WS25
WS3
2
2
4
5
455
595
1415
-- --
2340 4.67
2340 -- -6025 14.03
8340 -- --
2.02
2.65
6.29
-- --
10.41
10.41
26.80
37.10
LUGT2
LUGT3
LUGT4
LGT2
LGT3-SDS2.5
LGT4-SDS3
14
12
12
2
3
4
16
12
16
10d
WS25
WS3
-- --- --- --
10d
14
10d
1050
10d
14
10d
-- -16d Sinker 24 16d Sinker 3155
16d Sinker 32 16d Sinker -- -Concrete or Masonry Application
-- -5
1/4WB
1265
-- -4
3/8WB
-- --- -4
3/8WB
-- --
475
-- --- --
1915 5.63
5330 -- -6185 -- --
410
-- --- --
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.
2) Factored resistances apply where roof pitch is between 3:12 and 8:12.
3) Additional anchorage products to be designed by others.
4) 1/4WB denotes a 1/4" x 3" Powers "Wedge Bolt" or equivalent installed in a predrilled hole. Refer to manufacturer's literature for further information.
5) 3/8WB denotes a 3/8" x 5" Powers "Wedge Bolt" or equivalent installed in a predrilled hole. Refer to manufacturer's literature for further information.
6) Fasteners must be installed in fully grouted and reinforced concrete masonry (f'm = 1500 psi) or reinforced concrete (f'c = 2500 psi).
7) Minimum nail embedment shall be 8 nail diameters (typ).
8) For proper installation, the number of studs must be equal-to or greater-than the number of roof truss plies.
9) Wedge Bolts are not supplied with the LUGT2, LUGT3 or LUGT4.
10) NAILS: 8d x 1-1/2 are 0.131" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long, 16d Sinkers are 0.148" dia. x 3-1/4" long,
WS25 Wood Screws are 1/4" dia. x 2-1/2" long (supplied with LUGT3) and WS3 Wood Screws are 1/4" dia. x 3" long (supplied with LUGT4).
New products or updated product information are designated in red font.
1-800-328-5934 www.USPconnectors.com
1645 4.83
5260 -- -5300 -- --
1.82 7.32
-- -- 23.40
-- -- 23.58
The LUGT series is an extremely adaptable tiedown for girder trusses and offers several installation options to
accommodate different framing conditions. It is an ideal retrofit solution to reinforce truss connections to transfer
high wind loads to supporting walls and can be used on either wood framed, concrete or CMU block walls.
Install a minimum
of (12) 10d nails
into back
Install a minimum
of (4) 10d nails
into the top
Installation:
Use all specified fasteners. See Product Notes, page 10.
When straps are wrapped over the truss, install nails in backside of truss.
See MUGT15 installation diagram for minimum nail requirements into the
face and on top of the truss.
If installed straight-up with no wrap over the top of the truss, fill all nail
holes.
Moisture barrier may be required.
Install a minimum
of (6) 10d nails
into the face
1 1/4"
MUGT15
5/8" Bolt
Support Beam
Designed
By Others
Min 3"