Professional Documents
Culture Documents
$&02725&21752//(5
SN6F!Tfsjft!
FOREWORD
! ! Thank you for adopting RHYMEBUS “RM5E Series” high-
functioned simple type inverter. Prior to installation please peruse this
operation manual. For proper installation and safety use, the operation
manual should be attached to the machine. Meanwhile setting values
and parameters being set up should be recorded (on Attachment II) as
references for future maintenance or malfunction troubleshooting.
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
SAFETY PRECAUTION
! ! Please read this manual thoroughly and note safety precautions in
the contents and symbols or words marked with “DANGER” and
“CAUTION” prior to installation, wiring, operation maintenance and
troubleshooting.!!
!
! ! Following safety precautions require particular attentionǺ
DANGER
1. May not conduct wiring work during power transmission in order
to prevent electric shock.
2. R, S, and T terminals, connected to power source, are power input
terminals of inverter. U, V, and W terminals, connected to motor,
are power output terminals of inverter. The care that P, N, P1, and
PR terminals can not be connected to either power source or motor
must be made.
3. After turning power off, please do not touch the inverter or change
the wiring before CRG indicator light on the operation panel is
off.
4. The terminals of main power circuit and control circuit can not be
connected to PE terminals.
5. After wiring is completed, the inverter cover should be put on to
prevent other people’s touch.
6. RM5E inverter may not be connected to 346/380/415/ 440/460/
480V power source.
7. Operators should keep away from the motor before the inverter
transmitting power.
8. The wirings of main circuit and control circuit should be
separated; the ground wire should match with third grounding
method. (ground resistance under 100͈).
9. The wiring electrician should be a qualified professional.
10. The inverters do not equipped with explosion-proof devices,
therefore should be kept away from oil, gas…. explosible areas.
!!!!! CAUTION
1. During installation, the inverters should be kept away from areas
of high temperature, humidity, oil gas, cotton streaks, iron powder,
copper powder or corrosive substances.
2. While being installed in a control panel, ambient temperature may
not exceed 50к.
3. Isolated wires for control signals are recommended to prevent
noise interference, grounding should be noted as well.
4. Descriptions and installations of terminals of wiring drawings
(1) Wiring should be made according to the symbols of terminals,
and keep terminals connected tightly with screws.
(2) Appropriate wire diameter (refer to Electrical Code) should be
used for power source wiring. Connect main circuit R, S and T
terminals to power source (for single phase power source
connect to L1 and N terminals).
(3) Place appropriate specification of no fuse brake (NFB) or fuse
to power source input terminals of inverter; install a thermal
relay (THRY) between each motor and inverter when a high-
capacity inverter is used to drive multiple small rated power
loads.
(4) After output terminals (U, V, W) of inverters have been
disconnected, pressure resistance and insulation of motor can
be then tested. Note that pressure-resistance test to inverter can
be performed only by experienced personnel.
(5) Only qualified professionals could undertake tasks of
installation, wiring, test run or troubleshooting…, and etc.
!
!
!
!
!
!
!
INTRODUCTIONS
! FEATURES
ΘCompact
ΘLow noise
ΘAutomatic voltage regulation
ΘUser-friendly
ΘRestart after instantaneous power interruption
Θ9 speed level selections and 5 independent acceleration / de-
celeration time settings
Θ4 digit display
ΘProgrammable input and output
ΘFunctions of setting data copy and memory (function only when
KP-201C keypad is attached)
ΘSlideway
ΘLow noise!!
! Adopt IGBT of which maximum switching frequency up to 16KHz
to lower motor noises and smooth operation. Sinusoidal PWM
controls to acquire better efficiency.!
!
General Model
!
ʳ
ΘAutomatic voltage regulation (AVR)
Not to be influenced by the fluctuation of regional power source
voltage; voltage and torque remain unchanged while outputting.!
ΘUser-friendlyʳ
Besides an operation panel of the inverter, a digital keypad (KP-
201C) can be attached for remote control. Only general telephone
cable (8 pin) is needed, and the user may produce distant line
according to construction distance, time-saving and labor-saving
(maximum distance may reach 25 meter).!!
ΘRestart after instantaneous power interruptionʳ
During operation, the inverter may encounter instantaneous power
interruption, under such circumstance, may set up tracking motor
speed for automatic restart to resume operation status before
interruption.
Θ9 speed level selections and 5 independent acceleration / de-
celeration time settingsʳ
There are 5 independent acceleration / deceleration time settings
which ranges from 0.0 sec. to 320.0 sec. within nine speed level
selections. For acceleration from 0.0Hz to 60.0Hz the fastest is
0.015 sec. (excluding free running), the slowest 192000 sec.!!
Θ4 digit displayʳ
Can display 11 statuses (frequency, speed, voltage, current, and etc.)
ΘProgrammable input and outputʳ
For input terminal X1~X4 there are 25 programmable functions,
and one set of relay output terminal has 17.!!
ΘFunctions of setting data copy and memory!
The setting data of inverters can be stored in KP-201C keypad, then
rewrite to other inverter. This function applies to the condition of
multiple inverters with one single setting. Please note all software
versions should be consistent (software version setting item no.
F_000) in order to carry out parameter copy.!!
!
#ONFIRMATION OF PRODUCT
! ! !LTHOUGH THIS PRODUCT IS UNDER RIGOROUS QUALITY CONTROL
HOWEVER DAMAGES TO THE PRODUCT MAY BE MADE DURING
TRANSPORTATION CONSIDERING FACTORS LIKE IMPACT VIBRATION AND ETC
4HEREFORE UPON RECEIVING THIS PRODUCT CERTAIN CHECKUPS SHOULD BE
TAKEN )F THERE IS ANY DEFECT PLEASE CONTACT YOUR LOCAL DEALER
IMMEDIATELY
! #ONFIRMATION OF APPEARANCE
! #HECK IF THERE IS ANY DAMAGE DISTORTION TO THE APPEARANCE
" #HECK IF THE CONTENTS OF THE NAMEPLATE MATCH WITH THE PRODUCT
YOU ORDERED !
˜˦ˢʳˌ˃˃˄ʳ˖˘ʳ˜ˣ˅˃
˧ˬˣ˘ ˥ˠˈ˘ˀ˅˃˃˅ ʈ -ODEL NUMBER
6 1 9 1 1 1 2
# -ODEL NUMBER SCHEME
˥ˠˈ˘ʳʳʳʳˀʳʳʳʳ˅ʳʳ˃˃˅
Κ2ATED POWER (0
Κ)NDICATE 6
3ERIES NUMBERΚ2-% n %CONOMIC TYPE
BRAKING TRANSISTOR BUILT IN
$ #ONFIRMATION OF ACCESSORIES
'ENERALLY THERE IS ONE USERS MANUAL )F THERE ARE SOME
ACCESSORIES SUCH AS BRAKING RESISTOR ETC ARE ORDERED PLEASE
CHECK INCLUSIVELY
¨CHECK ITEMS BEFORE INSTALLATION
ʳ
E. Please refer to the standard specifications and confirm to your
requirements.
F. Dimensions (unitǺmm)
2
¨&+(&.,7(06%()25(,167$//$7,21
ʳ
,QYHUWHUVSHFLILFDWLRQ
$6WDQGDUGVSHFLILFDWLRQ
0RGHOQXPEHU
50(
5DWHGSRZHURI
WKHPRWRU
+3.:
5DWHGFRQWLQXRXV
RXWSXWSRZHU
.9$
5DWHGFRQWLQXRXV
RXWSXWFXUUHQW$
5DWHGRXWSXW
7KUHHSKDVHa9
YROWDJH
0D[LPXPRXWSXW
+]
IUHTXHQF\
6LQJOHSKDVHWKUHH 7KUHHSKDVHǵ
3RZHUVRXUFH
SKDVHǵ9 9
3Kǵ9ǵ+]
ǵ+] ǵ+]
7ROHUDQFHRI
SRZHUVRXUFH 9a9ǵ+]
YROWDJH
7ROHUDQFHRI
IUHTXHQF\ ʝ
IOXFWXDWLRQ
&+(&.,7(06%()25(,167$//$7,21
%&RPPRQVSHFLILFDWLRQV
%XLOWLQRSHUDWLRQSDQHOLQFOXGHIUHTXHQF\
VHWWLQJV95ǵ581ǵ67235(6(7ǵ352*ǵ
8VHULQWHUIDFH )81'$7$ǵɇǵɐǵIRXUGLJLW
GLVSOD\ǵ´+=´ǵ´9´ǵ´$´ǵ
´5(9´ǵ´581´ǵ´&5*´LQGLFDWLRQOLJKW
&RQWUROPHWKRG 6LQXVRLGDO3:0FRQWURO
5DQJHRI
ɴ+]
IUHTXHQF\VHWWLQJ
5HVROXWLRQRI 'LJLWDODQGDQDORJVLJQDOVHWWLQJVǺ+]ǵ
IUHTXHQF\VHWWLQJ 95VHWWLQJǺUHVROXWLRQ+]ȰXQGHU+]ȱ
5HVROXWLRQRI
+]
&RQWUROFKDUDFWHULVWLFV
RXWSXWIUHTXHQF\
'&9.͈ǵP$͈ǵ
$QDORJLQSXW
3RWHQWLRPHWHU.͈:%7<3(
2YHUORDGFDSDFLW\ UDWHGRXWSXWFXUUHQWIRUPLQXWH
)LYH VHFRQGIUHHUXQQLQJaVHFRQGV
DFFHOHUDWLRQ LQGLYLGXDODFFHOHUDWLRQGHFHOHUDWLRQVHWWLQJ
GHFHOHUDWLRQ WLPHUDQJHRIDFFHOHUDWLRQIURP+]WR+]LV
WLPH VHFRQGVWRVHFRQGV
'&EUDNLQJ $GMXVWDEOHWLPHIUHTXHQF\DQGOHYHO
$URXQGEUDNLQJUHVLVWDQFHDWWDFKHGPD\
%UDNLQJWRUTXH
UHDFKDURXQG
9)SDWWHUQ &DQVHWXS9)SDWWHUQDUELWUDULO\
6WDOOSUHYHQWLRQ 7KHFXUUHQWOHYHORIVWDOOSUHYHQWLRQFDQEHVHWXS
FKDUDFWHULVWLFV
2SHUDWLRQ
&RQWURORIGLUHFWLRQRIURWDWLRQIRUZDUGUHYHUVH
,QSXW
2SHUDWLRQ
URWDWLRQLVFRQWUROOHGE\XVLQJOLQHVXVWDLQLQJ
PHWKRG
FLUFXLWWRWDOVSHHGVHOHFWLRQV
¨&+(&.,7(06%()25(,167$//$7,21
ʳ
6WRSFRPPDQGE\XVLQJWKHOLQHVXVWDLQLQJ
FLUFXLWMRJJLQJRSHUDWLRQVHFRQGDU\
DFFHOHUDWLRQGHFHOHUDWLRQWLPHUHVHWFRPPDQG
PXOWLSOHOHYHOVSHHGFRPPDQGaH[WHUQDO
DEQRUPDOFRPPDQGFRPPDQGRILQKLELWLQJ
RXWSXWFRPPDQGRIVWRSYLDIUHHUXQQLQJ
0XOWLSOH FRPPDQGRIVSHHGVHDUFKIURPWKHPD[LPXP
IUHTXHQF\FRPPDQGRIVSHHGVHDUFKE\VHW
IXQFWLRQ
IUHTXHQF\DFFHOHUDWLRQGHFHOHUDWLRQLQKLELWLRQ
LQSXW FRPPDQGXSGRZQFRPPDQGXSGRZQVHW
VHWWLQJ IUHTXHQF\FOHDUFRQILUPDWLRQNH\'&EUDNLQJ
DFFHSWDQFHDWVWLOOVHOHFWLRQRIPDLQVHFRQGDU\
VHWIUHTXHQF\IRUZDUGFRPPDQGUHYHUVH
FRPPDQGLQSXWRI3/&DXWRPDWLFRSHUDWLRQ
FRPPDQGLQSXWRI3/&VXVSHQVLRQFRPPDQG
LQSXWRIFRXQWHUFRQWDFWVLJQDOFRXQWHUFOHDU
SURJUDPPDEOHLQSXWWHUPLQDOFRQWDFWDDQGE
$QDORJ 95DQG$,&209ȐP$ȑRU9
LQSXW ȐP$ȑ
5XQQLQJFRQVWDQWVSHHG]HURVSHHGIUHTXHQF\
GHWHFWLRQRYHUORDGGHWHFWLRQVWDOOSUHYHQWLRQ
XQGHUYROWDJHEUDNLQJUHVWDUWDIWHULQVWDQWDQHRXV
0XOWLSOH SRZHULQWHUUXSWLRQUHVWDUWDIWHUWURXEOHVKRRWLQJ
2XWSXW
IXQFWLRQ H[FHSWLRQDOFRQGLWLRQV3/&DXWRPDWLFRSHUDWLRQ
RXWSXW GHWHFWLRQRQHSKDVHUXQQLQJFRPSOHWHGRQH
VHWWLQJ F\FOHUXQQLQJFRPSOHWHGDXWRPDWLFRSHUDWLRQ
VXVSHQVLRQVHWWLQJYDOXHUHDFKHGLQGLFDWHGYDOXH
UHDFKHGSURJUDPPDEOHRXWSXWWHUPLQDOFRQWDFWD
DQGE
FKDUDFWHULVWLFV
2SHUDWLRQ
$QDORJ JDLQDQGELDVYROWDJHRXWSXWIUHTXHQF\VHWWLQJ
RXWSXW IUHTXHQF\DQGRXWSXWFXUUHQWFDQEHVHOHFWHGDV
UHSUHVHQWLQJLWHPDUELWUDULO\
¨#(%#+ )4%-3 "%&/2% ).34!,,!4)/.
ʳ
3TART FREQUENCY START VOLTAGE ADJUSTMENT !62
UPPER AND LOWER BOUND OF FREQUENCY FREQUENCY
/THER FUNCTIONS HOPPING EXTERNAL FREQUENCY COMMAND GAIN
ADJUSTMENT EXTERNAL FREQUENCY COMMAND BIAS
VOLTAGE ADJUSTMENT 6&