Ref.No.

- IDAX/QUO/ORHPL/2016-17/057A
To,
The Project Manager,
Date:- 04.08.2016
ORANGE RENEWABLE HOLDING PVT LTD.
#301B, 3rd Floor, D21 Corporate Park, Sector-21 Dwarka,
Landmark: Near Sec-8 Metro Station Dwarka, New Delhi-110075.
Mob: + 91-9013223869 | Tel: +91-011-30501110-13
SUB:- Quotation for Soil Investigation & Survey for 40MW solar Project at Charanka Solar Park Gujarat.
Ref:- email: Mon, Aug 1, 2016 at 2:48 PM
Kind Attn:- Mr. Rakesh Singh- Assistant Manager- Procurement (Solar).
Dear Sir,
With reference to the above said subject, the Quotation for Soil Investigation & Survey for 40MW solar
Project at Charanka Solar Park Gujarat.
UNIT
ITEM
AMOUN
SCOPE OF WORK
QTY UNIT
RATE
NO
T (Rs)
(Rs)
Mobilization
&
Demobilization:
One Time Mobilization and demobilization of Machinary1
1
Nos
25000
25000
equipments and personnel required to execute the job as per
specification.
Conducting Soil investigation (bore hole) as per IS : 1892
1997 & IS : 4464 by manual augering or calex type rotary
drilling machine of 100 - 150 mm diameter with casing pipe /
bentonite slurry if required, for supporting inner collapsible
stratum below water table with pot holes / helical auger in 30
2
Nos
6000
180000
soft / normal soil up to the depth of 5.0 mt or up to the depth
of refusal*. Drilling NX size diameter bore hold by using
calex type rotary drilling machine (with the help of TC bit) in
soft.
Conducting Soil investigation (bore hole) as per IS : 1892
1997 & IS : 4464 of 100 - 150 mm diameter by Drilling /
chiseling in rock including collection of core sample,RQD,
3
1
Nos
7500
7500
Crushing strength in all condition up to the depth of 3.0 mt
or up to the depth of refusal* for boulder / soft to hard rock
type soil .

Collection of disturb & undisturb (chunk sample through


shelby tube of 70 mm / 100 mm diameter) samples as per IS :
2132 : 1986 & IS : 1892 : 1979 at every 0.5 mt depth
interval or change of strata whichever is earlier up to
maximum specified depth or refusal* whichever is earlier, 30
including cleaning, sealing, sorting & Conducting standard
penetration test (SPT) N value as per IS : 2131 1987
to evaluate the penetration resistance of soil at every 0.5
mt depth or change of strata whichever is earlier and up to
maximum specified depth or refusal* whichever is earlier.
Conducting relevant laboratory test on the DS / UDS
samples collected during exploration work as per latest
Indian Standard or as specified in the scope of work.
Submission of proper analytical & graphical report with
detail calculation & design of soil bearing capacity, soil
bearing pressure etc as per codal provision.
Sl. No
Name
1.
Moisture content
2.
Specific gravity
3.
Bulk and dry density
4.
Grain size analyses
30
5.
Liquid, plastic and shrinking limits
6.
One dimensional consolidation
7.
Tri-axial comprehension : Unconsolidated
un-drained
8.
Unconfined comprehension
9.
Direct shear
10.
Unit weight of rock
11.
Crushing strength of rock
12.
Chemical analysis of soil
13.
Chemical analysis of ground water e.g.
Conducting Topography & Contour survey by using Total
station of Sokkia / Trimble make with
1 to 3 second accuracy. The survey includs marking of
important structure, utility lines (i.e electric line, telephone
line, water line, gas line) etc visible on ground only. The
ground levels will be collected in appropriate grid & contour 180
will be plotted at interval of 0.5 mt / 1.0 mt or as per
topography. Temporary benchmark will be established on
any existing structure. Submission of survey drawing in one
soft copy & one hard copy after approval by concern
authority only.
Conducting Electric Resistivity Test (based on Wenners
configuration) to evaluate the resistivity of soil up to
required depth at a pin spacing of 1m, 2m, 3m, 5m & 10m in
eight direction i.e (N, S, E, W, N-E, S-E, S-W and N- W) as
per IS : 3043. Submitting detail analysis of resistance R 15
(ohm mt) value (R = ration of potential V & current I),
polar curve for specific depth, graph of depth (mt) Vs
resistivity (ohm mt) etc as per codal provision.

Nos

250

7500

Nos

1000

30000

Acre

600

108000

NOs

1000

15000

Fixing the coordinates on the ground and Marking of


Boundary lines of the Plots, mapping of the plots and
providing the soft(Autocad)and hard copies of the plotlayout
with all dimansions and preparing minimum 50 numbers
180
TBM of 1000mm height above ground at site with North,
East and RL value clearly marked on it. Also all the TBM's
shown in AutoCAD drawing of Contour and Boundary
Survey
Chemical analysis of soil and water sample to foundation
material all complete Determination of ph value, Sulphate 2
and Chloride content etc
TOTAL

Acre

150

27000

Nos

1000

2000
402000

Terms and Conditions:


1- Service tax extra as applicable.
2- 25% of the total amount as advance along with the PO.
3- 50% of the total amount after completion of field activities.
4- 25% of the total amount after submission of reports.
5- Mobilization schedule is 7 days from the date of receiving the PO.
6- Completion schedule is 20 days from the date of start of work.
7- The above rates are applicable for this project area only.
8- Entry Pass/ Gate Pass / Exit Pass have to be provided by the client if needed.
9- The above quantities are are variable up to +/- 10%.
10- Any delay in work or damage due to local issue or any other unforeseen circumstances will be
compensated by the client.
Thanking you & assuring for best service always.
Yours Faithfully,
For IDAX CONSULTING & RESEARCH PVT. LTD.

(Authorized Signatory)