You are on page 1of 30

1995

1998

2000

About us
AIRMEEX was founded in 1995 in Valenton by Mr Caliskan, Mr
Erol and Mr Biancotto. They had developped innovating concepts on
engines depollution and material protection on hazardous area.

Since then, the owners use creative ideas and market trends for
producing new products and solutions for our customers.
All new products meet high quality standards with current tech-

The company is a real success, gets bigger and had to move out
every year until 2003 when AIRMEEX builds its new plant in Vigneux
sur Seine.
Airmeex is one of the leading companies in producing exhaust
gas reduction systems and hazardous area material protection.

nologies.
We are a dynamic and strong team and our business drivers
brought us up to the top in the last years. For satisfying our customers requirements and for delivering high quality, we have
expanded our locations.

We have been supporting our customers with innovating technics


and comprehensive know how for 10 years.

Following the products of our company.

ATEX - IP
Protection

ELECTRIC ZONE 2 IIB T3 - T4


SAFEX system category 3G
ELECTRIC ZONE 1 IIB T3 - T4
EUROPEX system category 2G

TRANSPALET ZONE 1 IIB T3 - T4


EUROPEX system category 2G

ELECTRIC ZONE 22
system SAFEX 3D category 3D
ELECTRIC ZONE 21
system SAFEX 2D category 2D
DIESEL ZONE 2 IIB T3 - T4
DIESEX system category 3G
DIESEL ZONE 1 IIB T3-T4
system MOBILEX category 2G
DIESEL ZONE 22
system DUSTEX 3D category 3D
DIESEL ZONE 21
system DUSTEX 2D category 2D

MANUAL TRANSPALET ZONE 1 - 21


system EUROPEX category 2GD

IP44 - 55 - 65 - PROTECTION
PROOFEX System

DIRECTIVE ATEX 94/9/EC


The ATEX directive EC/94/9 describe new guidelines for explosion
proof material manufacturer and end user.
The ATEX Directive 94/9/EC is applied in 1st July 2003, after this date only materials complying with this directive could be sold and
used in the European Community.

HAZARDOUS AREAS
DEFINITIONS
EXPLOSIVE ATMOSPHERE
It is a mixture, in air, of flammable vapour, fog or dust which,
after the explosion, is propaged to the unburnt explosive mixture.

MAIN REQUIREMENTS
OF ATEX DIRECTIVE

An explosive atmosphere may be present either as during normal operation or the result of an incident such
- Mechanical failure (pump, valve, sensor, etc..)

Either the conformity of the product (by CE type approval) and


the quality management system of the manufacturer is under the
control of the notified body (Ex INERIS)
The CE marking on product means that the product comply the
ATEX directive but also to the Machine Directive, CEM , etc...
- The ATEX directive makes the distinction between the dangerous areas with:
Explosive vapour (letter G= gas) or and
Explosive dust (letter D=Dust)
The certification procedure is different for this two materials
and the corresponding marking also.
New designing and manufacturing rules are applied to maximize
the safety level of ATEX materials during all their working life.
Working conditions of protected materials are mostly considered
such as humidity, vibration, pollution, voltage peaks.
The Fail Safe condition is applied to the main safety components.

- Electrical failure
(short circuit, lightning, ambient temperature increasing)
- Electrostatic discharge

WHAT IS MAKING THE EXPLOSION ?


Solvents, gas , vapour, hydrocarbons , petrol , perfume, pharmaceuticals products, aerosol filling,
Powder and dust like magnesium, aluminium, sulphur, coal , wood, milk, sugar, polystyren, toner and
agricultural products.

PARAMETERS

CONDITIONS

Ignition temperature

To make the explosion these 3 elements are required

This is the lowest temperature at which the vapor or dust will


be ignitated.

oxygen - needed for combustion

The ignition temperature is classified to T6 to T4


(Maximum surface temperature )

L.I.E.
This is the lower limit of explosivity.
This the miminum concentration level of a dangerous liquid
that should ignitated in air

L.S.E.
This is the higher limit of explosivity.
This the maximal concentration (Vapour, gas, dust) under that
the mixture could ignitated

FLASH POINT
This the lowest temperature at which a dangerous liquid
generates enough vapour to ignitated.

combustible - gas or vapour


a hot spot or spark - to ignitated

HAZARDOUS AREA CLASSIFICATION - ATEX CATEGORIES


Zone

20

21

22

Nature of the atmosphere

Gas

Dust

Gas

Dust

Gas

Dust

Explosive
Atmosphere

Permanent presence

Intermittent presence

Manufacture of Products
Industry Activity
ATEX Directive
category 94/9/CE

Tanks or reactors

1G

1D

Handling of products in bulk


or unpacked
2G

2D

For Diesel
Applied standards
DIESEL FORKLIFT

No protection possible
for forklift
Only EEx ia
for electronic devices

For electric part

Applied standards
ELECTRIC FORKLIFT

No protection possible
for forklift
Only EEx ia
for electronic devices

AIRMEEX system

Storage area - Logistic


Packaged products
Closed drums
3G

3D

For Diesel

ZONE 1 IIB
T3 or T4
comply En 1834-1

AIRMEEX system

Occasional presence

for Diesel
ZONE 21
comply EN1834-3

ZONE 2 IIB
T3 or T4
comply En 1834-1

For Diesel
ZONE 22
comply En 1834-3

EEx d IIB T4
EN 50014-EN 50018
EN 50019-EN 50020

For electric part


IP 6x - EN60529

For electric part


EEx d IIB T4
EN 50014-EN 50018
EN 50019-EN 50020

For electric part


IP 5x - EN60529

MOBILEX

DUSTEX 2D

DIESEX 3G

DUSTEX 3D

ZONE 2 IIB
For electric part

For electric part

For electric part

IP 6x - EN60529
directive 94/9/EC

EN 50054
EN 50057
EN 50021

IP5X-EN 60529
directive 94/9/EC

EUROPEX

SAFEX

SAFEX

SAFEX 3D

EEx d IIB T4
EN 50014-EN 50018
EN 50019-EN 50020

Class T Cenelec

T6

T5

T4

T3

T2

T1

Maxi surface T

85C

100C

135C

200C

300C

450 C

Representative gas group

IIA Propane

IIB Ethylen

IIC Hydrogen

ELECTRIC
ZONE 2 IIB T3-T4
SAFEX System
category 3G comply with
ATEX directive
94/9/EC
Head light
EEx d IIB T4

Flashing beacon
EEx d IIB T4

Tail lights
EEx d IIB T4

Gas detection system


box

Reverse bleeper
EEx nC

Gas test bottle

Stainless steel cladded


forks

Drive motor
Pump motor
EEx nR
Antistatic wheels
Control unit-contactor
box
EEx n R

The Protection System SAFEX TM adapts on any type of materials


of electric handling and fullfills the requirements of ATEX EC/94/9
directive for the equipment of group II category 3G .
SAFEX TM is the ideal solution for a maximum flame - proof protection for the needs for industries at the risks while qualities of the
materials of origin and them specifies.
3G category protection is subject to self certification of the manufactures.

The on board SAFEX TM gas detection system fitted on the forklift


could detect all explosive atmospheries in the working area and alert
or in the event of danger stop the machine in a satety way.
The electric parts which causes sparks or such as the motor or
contactors are protected according to EN 50021 to avoid any ignition
or explosion of the dangerous atmosphere.
All temperature sensors and safety accessories are fail - safe and
stop the forklift in all circumstances.
All plastic parts like wheels, seat and others which could generated electrostatic discharge are protected as well. Also mechanical parts
creating sparks or over heating are into account in the protection system such as brakes, forks and hydraulic parts.

ZONE 2 IIB T4 PROTECTION - SAFEX System


CATEGORY 3G ELECTRIC FORKLIFT
comply with ATEX directive 94/9/EC
1- Electrical components such as motors, controllers and
switches are EEx nR protected by enclosures to avoid an
immediate gas penetration.
2- Thermal switches are placed on each motor. Temperature
setting is T4 - 135C. If a high temperature occur, the
corresponding motor is stopped.

At 10% of LEL, a visual alarm is provided on the control box.


At 20% of LEL, an audible and visual alarm is provided to
go out the area.
At 25% of LEL, the main contactor stop the truck by
disconnecting the battery.
5- Test gas bottle (1 liter capacity - 100 bar).

3- A catalytic type, EEx d IIC T6 explosion proof certified, gas


detection head measure continuously the atmosphere.
This sensor is certified in conformity to EN 50054 - EN
50057.

6- Manual unipolar battery isolator enclosed in EEx d IIB T5


control box.

A gas test valve and gas bottle is incorporated to the forklift.

7- Earthing of the forklift is providing by a tin plated copper


between earth and forklift chassis.

Forklift start up is only possible when the integrity of the test


is confirmed.

8- Stainless steel cladding of forks.

4- An EEx d IIB T5 control box enclose the gas monitoring


system and also a main contactor and unipolar battery
isolator.

9- Manual horn.
10- Instructions manual.

Through a glass on the box, the LEL (Low Explosivity Level)


is screened on the monitor.

11- Zone 2 IIB T4 - 3G category certificate of conformity.

The gas detection head is stetted to detect 3 level of LEL.

12- 1 year or 1200 hours warranty for pieces.

ELECTRIC
ZONE 1 IIB T3-T4
EUROPEX System
category 2G comply with
ATEX directive 94/9/EC

Tail lights
EEx d IIB T4

Flashing beacon
EEx d IIB T4

Reverse bleeper
EEx i IIB T4

Head lights
EEx d IIB T4

Electric control unit


box
EEx d IIB T4

Antistatic
seat

Intrinsic Safety switch


control
EEx i IIB T4

Stainless steel cladded


forks
Pump motor
EEx d IIB T4

Drive motor
EEx d IIB T4
Antistatic wheels

Airmeex is notified by INERIS to design and manufacture products for explosive atmospheres guaranted to the last standards.
The Protection System EUROPEX TM adapts on any type of materials of electric handling and fullfills the requirements of ATEX
EC/94/9 directive for the equipment of group II category 2G for Zone 1.

The electric parts which causes spartes or such as the motor or


contactors are protected in according to CENELEC standards to avoid any ignition or explosion of the dangerous atmosphere.
All temperature sensors and safety accessories are fail - safe and
stop the forklift in all circumstances.

TM

Europex is the ideal solution for a maximum flame - proof protection for the needs for industries at the risks while qualities of the
materials of origin and them specifies.
CE confirmity is made out either by the constuction of the original
equipment or by Airmeex in accordance with ATEX directives.

All plastic parts like wheels, seat and others which could generated electrostatic discharge are protected as well. Also mechanical
parts creating sparks or over heating are into account in the protection system such as brakes, forks and hydraulic parts.

ZONE 1 IIB T4 PROTECTION - EUROPEX System


CATEGORY 2G ELECTRIC FORKLIFT
comply with ATEX directive 94/9/EC

1- Drive motor EEx d IIB T4 protected + surface temperature


sensor T4
2- Hydraulic motor EEx d protected + surface temperature
sensor T4

7- Manual horn
8- Plastic parts and seat with antistatic treatment
9- Stainless steel cladded forks

3- Battery connector EEx d IIC T6+IP65 - ATEX 2G


10- Brakes and hdyraulic temperature sensors
4- Control unit EEx d IIB T4 - ATEX 2G protected with battery
isolator

11- Instructions manual

5- Control switches, temperature sensor intrinsic safety


protected EEx i IIC T5 - ATEX 2G

12- Zone 1 IIB T4 - 2G category certificate of conformity

6- Earth cable link between electrical components

13- 1 year or 1200 hours warranty for pieces

ELECTRIC TRANSPALET
ZONE 1 IIB T3-T4
EUROPEX System
category 2G comply with
ATEX directive
94/9/EC
Battery Connector
EEx d IIB T4

Electric control unit


box
EEx d IIB T4

Stainless steel cladded


forks

Intrinsic Safety switch


control
EEx i IIB T4

Pump motor
EEx d IIB T4

ATEX Battery
EEx e II T6

Drive motor
EEx d IIB T4

Airmeex is notified by INERIS to design and manufacture products for explosive atmospheres guaranted to the last standards.
The Protection System EUROPEX TM adapts on any type of materials of electric handling and fullfills the requirements of ATEX
EC/94/9 directive for the equipment of group II category 2G for Zone 1.
Europex TM is the ideal solution for a maximum flame - proof protection for the needs for industries at the risks while qualities of the
materials of origin and them specifies.
CE confirmity is made out either by the constuction of the original
equipment or by Airmeex in accordance with ATEX directives.

The electric parts which causes spartes or such as the motor or


contactors are protected in according to CENELEC standards to avoid any ignition or explosion of the dangerous atmosphere.
All temperature sensors and safety accessories are fail - safe and
stop the forklift in all circumstances.
All plastic parts like wheels, seat and others which could generated electrostatic discharge are protected as well. Also mechanical
parts creating sparks or over heating are into account in the protection system such as brakes, forks and hydraulic parts.

ZONE 1 IIB T4 PROTECTION - EUROPEX System


CATEGORY 2G ELECTRIC TRANSPALET
comply with ATEX directive 94/9/EC

1- Drive motor EEx d IIB T4 protected + surface temperature


sensor T4

7- Manual horn

2- Hydraulic motor EEx d protected + surface temperature


sensor T4

8- Plastic parts with antistatic treatment

3- Battery connector EEx d IIC T6 + IP65 - ATEX II 2G

9- Stainless steel cladded forks

4- Control unit EEx d IIB T4 - ATEX II 2G protected with


battery isolator

10- Instructions manual

5- Control switches, temperature sensor intrinsic safety


protected EEx i IIC T5 - ATEX II 2G

11- Zone 1 IIB T4 - 2G category certificate of conformity

6- Earth cable link between electrical components

12- 1 year or 1200 hours warranty

ZONE 22 PROTECTION - SAFEX 3D System


CATEGORY 3D ELECTRIC FORKLIFT
comply with ATEX directive 94/9/EC

1- ELECTRIC COMPONENT PROTECTION

2- SAFETY

- Motors IP5X protected

- Surface temperature Sensors on each motors providing a


shutdown at 200C

- ECU IP5X protected


- Brake sensors at 200C
- Connectors and electrical components IP5X protected
- Stainless steel cladding of forks
- Battery connector IP5X
3- Zone 22 category 3D AIRMEEX certificate
4- Instructions manual
5- 1 year warranty or 1200 hours

ZONE 21 PROTECTION - SAFEX 2D System


CATEGORY 2D ELECTRIC FORKLIFT
comply with ATEX directive 94/9/EC

1- ELECTRIC COMPONENT PROTECTION

2 - SAFETY

- Drive, pump motors IP6X protected

- Surface temperature sensors on each motors providing a


shutdown at 200C

- Control unit-contactors IP6X protected


- Brake sensors at 200C
- Connectors and electrical components IP6X protected
- Seat and Plastic parts with Antistatic treatment
- Battery connector IP6X
- Stainless steel cladding of forks
3- Zone 21 category 2D AIRMEEX certificate
4- Instructions manual
5- 1 year warranty or 1200 hours

DIESEL
ZONE 2 IIB T4-T3
DIESEX system
category 3G
comply with Directive
ATEX 94/9/CE
Alternator
EEx d IIB T4
Head light
EEx d IIB T4

Inlet manifold including


flametrap

AIRMEEX patent
Start motor
EEx d IIB T4

Watercooled exhaustmanifold including self


cleaning

Stainless steel
cladded forks

AIRMEEX patent

The Protection System DIESEXTM adapts on any type diesel forklifts and fullfills the requirements of ATEX EC/94/9 directive for the
equipment of group II category 3G for Zone 2.

avoid hot surface temperature which can ignited the explosive


atmosphere.

DIESEX TM is the ideal solution for a maximum flame - proof protection for the needs for industries at the risks while qualities of the
materials of origin and them specifies.

The electric parts which causes sparks or such as the motor or


contactors are protected according to normes EN 50021 to avoid
any ignition or explosion of the dangerous atmosphere.

3G category protection is subject to self certification of the


manufacturer.

All temperature sensors and safety accessories are fail - safe and
stop the forklift in all circumstances.

The diesel engine is protected in the inlet and exhaust manifold


by self cleaning flame arrestor (Airmeex patent) which does not
required regular maintenance.
The exhaust heat exchanger is in double skin watercooled to

All plastics parts like wheels, seat and others which could generated electrostatic discharge are protectes as well. Also mechanical
parts creating sparks or over heating are into account in the protection system such as brakes, forks and hydraulic parts.

ZONE 2 IIB T4-T3 PROTECTION - DIESEX System


CATEGORY 3G DIESEL FORKLIFT
comply with ATEX directive 94/9/EC

1- ENGINE FLAME PROTECTION ZONE 2 IIB T3-T4

3- ELECTRIC STARTING SYSTEM

- Watercooled exhaust manifold/heat exchanger designed to


limit exhaust surface and exhaust gas to below to 200C.
Pressure tested to 10 bar.
- Spark arrestor tested in accordance with ATEX directive
- Inlet stainless steel flametrap IIB group
- 4 Exhaust stainless steel flametrap self cleaning IIB group
- High radiator capacity
- Manual emergency stop control
- Overspeed inlet shutdown valve
- Non metallic engine cooling fan, antistatic fan belt

- EEx d IIB T4 protected start motor, alternator and electric


junction box
- EEx nC protected battery
- EEx nC protected glow plugs
- EEx nC switches and sensors control
- Dash board indicator
High Engine coolant temperature gauge
Alternator charging lamp
Preheat glow plugs
Fuel level (minimum)
Exhaust, coolant, oil pressure warning lamp
- Hour meter

2- SECURITY
EEx nC controlled sensors provide an automatic inlet shut
down and fuel shut down simultaneously.
- High exhaust temperature sensor (200C)
- High coolant temperature sensor (99C)
- Low engine oil pressure sensor (0.8 bar)

4- Zone 2 category 3G AIRMEEX certificate


5- Instructions manual
6- 1 year warranty or 1200 hours

DIESEL
ZONE 1 IIB T3-T4
MOBILEX system
category 2G
comply with Directive
ATEX 94/9/CE

Work light
EEx d IIB T4
Flashing beacon
EEx d IIB T4

Electric controlbox
EEx d IIB T4
Control switches
EEx nC
Watercooled exhaustmanifold including self
cleaning

AIRMEEX patent

Stainless steel
cladding forks

Alternator
EEx d IIB T4

Start motor
EEx d IIB T4

Inlet manifold including


flametrap

AIRMEEX patent

Airmeex is notified by INERIS to design and manufacture products for explosive atmospheres guaranted to the last standards.
The Protection System MOBILEXTM adapts on any type diesel
motors and fullfills the requirements of ATEX EC/94/9 directive for
the equipment of group II category 2G for Zone 1.
MOBILEX TM is the ideal solution for a maximum flame - proof
protection for the needs for industries at the risks while qualities of
the materials of origin and them specifies.
CE confirmity is made out either by the constuction of the original equipment or by Airmeex in accordance with ATEX directives.

The diesel engine is protected at the inlet and exhaust manifold by self
cleaning flame arrestor (Airmeex Patent) which does not required regular
maintenance. The exhaust heat exchanger is in double skin watercooled to
avoid hot surface temperature which can ignited the explosive atmosphere.
The electric parts which causes sparkes or such as the motor or contactors are protected according to CENELEC standards to avoid any ignition or
explosion of the dangerous atmosphere.
All temperature sensors and safety accessories are fail - safe and stop
the forklift in all circumstances.
All plastics parts like wheels, seat and others which could generated
electrostatic discharge are protected as well. Also mechanical parts creating
sparks or over heating are into account in the protection system such as
brakes, forks and hydraulic parts.

ZONE 1 IIB T3-T4 PROTECTION - MOBILEX System


CATEGORY 2G DIESEL FORKLIFT
comply with ATEX directive 94/9/EC
1- ZONE 1 IIB T3 - 200C or T4-135C according
EN 1834-1 Diesel engine protection
- Inlet IIB group stainless steel flametrap
- Exhaust IIB group manifold integrated flametrap (NOCLEAN)
- Watercooled exhaust manifold
- Watercooled heat exchanger
- High coolant radiator
- Inlet overspeed shutdown valve
- Stainless steel ATEX spark arrestor
- Antistatic fan belt and fan
2- SAFETY
- All security sensors are failsafe connected and shutdown the
engine and the inlet valve
- Low oil pressure sensor at 0.8 bar
- High coolant water temperature sensor at 100C
- High exhaust temperature sensor at 200C - T3 or 135C - T4
- Manual emergency stop
- Stainless steel forks cladding
- Manual horn
- Antistatic seat
- Hand brake light
- Temperature sensor on brakes
- All plastics protected against electrostatic discharge

3- DASHBORD
- Engine coolant temperature thermometer
- Electronic warning light for alternator, oil pressure, overspeed, coolant temperature, exhaust temperature, mini fuel
level, brakes temperature
4- ATEX 2G - CENELEC Electric circuitry
- EEx d IIB T4 electric start motor
- EEx d IIB T4 alternator
- EEx e II T6 battery
- EEx d IIB T4 glow plugs
- EEx d IIB T4 control box including bipolar manual isolator
- EEX i IIB T4 intrinsic safety switches and sensors control
5- Zone 1 category 2G AIRMEEX certificate
6- Instructions manual
7- 1 year warranty or 1200 hours

ZONE 22 PROTECTION - DUSTEX 3D System


CATEGORY 3D DIESEL FORKLIFT
comply with ATEX directive 94/9/EC
1- ENGINE PROTECTION comply with EN1834-3

3- ELECTRIC PROTECTION

- Watercooled exhaust manifold/heat exchanger designed to


limit exhaust surface and exhaust gas to below to
300C/200C

- IP5X protected start motor, alternator and electric


junction box
- IP5X protected battery connexion

- Non metallic engine cooling fan, antistatic fan belt


- Dash board indicator
- Spark arrestor tested in accordance with ATEX directive
2 -SAFETY
-

All sensors provide an visual alarm


High exhaust temperature sensor 300C/200C
High coolant temperature sensor 99C
Low engine oil pressure sensor 0.8 bar
Stainless steel cladding of forks

High Engine coolant temperature gauge


Exhaust tempertaure
Oil pressure
4- Zone 22 category 3D AIRMEEX certificate
5- Instructions manual
6- 1 year warranty or 1200 hours

ZONE 21 PROTECTION - DUSTEX 2D System


CATEGORY 2D DIESEL FORKLIFT
comply with ATEX directive 94/9/EC
1- ENGINE PROTECTION comply with EN1834-3

3- ELECTRIC PROTECTION

- Watercooled exhaust manifold/heat exchanger designed to


limit exhaust surface and exhaust gas to below to
300C/200C
- Non metallic engine cooling fan, antistatic fan belt
- Spark arrestor tested in accordance with ATEX directive

- IP6X protected start motor, alternator and electric junction box


- IP6X protected battery connexion
- Dash board indicator
High Engine coolant temperature gauge
Exhaust temperature
Oil pressure

2- SAFETY
4- Zone 21 category 2D AIRMEEX certificate
-

All sensors provide an engine stop


High exhaust temperature sensor 300C/200C
High coolant temperature sensor 99C
Low engine oil pressure sensor 0.8 bar
Seat and Plastic parts with Antistatic treatment
Stainless steel cladding of forks

5- Instructions manual
6- 1 year warranty or 1200 hours

MANUAL TRANSPALET
ZONE 1-21
2GD category
comply with
ATEX 94/9/CE

- Possibility of using in hazardous areas


- Zone 21 and zone 1
- ATEX certification category 2GD by INERIS
- Wheels and forks wheels conductive
- High strength stainless steel 304L frame and forks
- Safety handle with automatic stop lowering
- Slow lifting adjustable with care

TECHNICAL PROPERTY SERIE ATM 20 - ATM 30

Capacity

2000 kg

3000 kg

Forks width

540 mm

540 mm

Forks lenght

1150 mm

1150 mm

Fork width

160 mm

160 mm

Mini height

85 mm

85 mm

Lift

210 mm

210 mm

Total lenght

1510 mm

1510 mm

Turning radius

95

95

Wheel diameter

180 x 50

190 x 50

Fork wheel diameter

80 x 65

80 x 65

Weight

95 kg

100 kg

Certification

INERIS 03 ATEX 3007 Categorie 2GD

Material

INOX 304L

IP44 - 55 - 65 PROTECTION
PROOFEX System comply with EN 60529
Airmeex is specialized to design and produce products for dangerous area or special requirements.
The protection system PROOFEX is adapting to all kind of electrical machine working in hostile environment.
PROOFEX is the ideal solution for a maximal protection of your
devices by keeping all the original characteristics in the same time.
The electrical parts like motors, conatctors, ECU, switches are
protected regarding CENELEC standards to avoid any penetration of
dust or liquid.
Each enclosed motor is also temperature controlled by a sensor
providing a shutdown in case of overheating.
AIRMEEX could realize special protection for cold areas or
against corrosion.

IP55 PROTECTION
-

Drive, pump motors enclosed in stainless steel IP55 box


Control unit, contactors enclosed in stainless steel IP55 box
Control switches IP55 protected
Electrical and battery connectors IP55 protected
Surface temperature sensors
IP55 Airmeex certifcate of conformity

IP65 PROTECTION
-

Drive, pump motors enclosed in stainless steel IP65 box


Control unit, contactors enclosed in stainless steel IP65 box
Control switches IP65 protected
Electrical and battery connectors IP65 protected
Surface temperature sensors
IP65 Airmeex certificate of conformity

DRIVE MOTOR
IP 55 ENCLOSED

PUMP MOTOR
IP 55 ENCLOSED

CONTROL UNIT
IP 55 ENCLOSED

Safety
Accessories

SHUTDOWN VALVE

SPARK ARRESTOR

FLAME ARRESTOR

STANDARD SILENCER

SHUTDOWN VALVE
The use of a diesel engine in hazardous areas such as the OIL
and CHEMICAL INDUSTRIES requires the use of a shutdown valve.
A diesel engine which absorbs hydrocarbon in the atmosphere is
likely to rev up and can only be stopped by a shutdown valve used
as an emergency stop.
Placed between the air filter and the inlet manifold, it closes the
air inlet by the use of a controlled valve.
Different control options are available:
-

MANUAL by a handle
ELECTRIC by an emergency stop button and solenoid
12V or 24V
PNEUMATIC by an emergency stop button and jack
AUTOMATIC by depression (overspeed)

A simultaneous action can stop the fuel injection to avoid to


destroy the engine cylinders.

For applications in a positive security the valve can be normally


closed NC which means that an armament is necessary when starting the engine. For standard applications the valve is normally open
NO.

Technical Specifications

ELECTRIC SHUTDOWN VALVE

Airmeex Code
A 200001
A 200002
A 200003
A 200004
A 200005
A 200006
A 200007
A 200008
A 200009
A 200010
A 200011
A 200012
A 200013
A 200014
A 200015
A 200016
A 200017
A 200018

Type

ADN 40E - 12v


ADN 40E - 24v
ADN 50E - 12v
ADN 50E - 24v
ADN 60E - 12v
ADN 60E - 24v
ADN 68E - 12v
ADN 68E - 24v
ADN 75E - 12v
ADN 75E - 24v
ADN 90E - 12v
ADN 90E - 24v
ADN 100E - 12v
ADN 100E - 24v
ADN 120E - 12v
ADN 120E - 24v
ADN 130E - 12v
ADN 130E - 24v

42

70

52

31

70

20

30

52

80

65

36

80

25

30

62

100

71

46

80

25

30

68

109

78

51

80

25

30

75

130

86

58,5

80

25

30

90

140

106

66

80

25

30

100

150

126

71

80

25

30

122

180

140

86

90

30

30

132

180

150

86

90

30

30

PNEUMATIC SHUTDOWN VALVE

Airmeex Code
A 200023
A 200024
A 200025
A 200026
A 200027
A 200028
A 200029
A 200030
A 200031

Type
ADN 40P
ADN 50P
ADN 60P
ADN 68P
ADN 75P
ADN 90P
ADN 100P
ADN 120P
ADN 130P

42
52
62
68
75
90
100
122
132

70
80
100
109
130
140
150
180
180

52
65
71
78
86
106
126
140
150

31
36
46
51
58,5
66
71
86
86

70
80
80
80
80
80
80
90
90

20
25
25
25
25
25
25
30
30

30
30
30
30
30
30
30
30
30

SPARK ARRESTOR
A spark arrestor is designed to stop sparks coming from the
DIESEL engine to avoid the propagation of explosion or fire in dangerous areas such as
-

Petrol refinery
Chemical plants
Silos
Pharmaceutical plants
Explosive transport

No maintenance is required due to a self cleaning operation of


the particulate contain inside.
Spark arrestors can be fitted in horizontal or vertical position at
the end of the exhaust line or designed as a complete silencer.

The AIRMEEX ASS series are in stainless steel construction, with


a dry cyclonic effect which extinguished the sparks.
All type are in accordance with ATEX Directive or OCMA MEC-1
specifications.

Airmeex Code

Type

A int. B ext.

Atmospherique

Turbo

10 - 45 cv
0 - 7,5 Kw
10 - 70 cv
7,5 - 51 Kw
10 - 45 cv
7,5 - 33 Kw
25 - 88 cv
18 - 65 Kw
50 - 180 cv
37 - 132 Kw
150 - 265 cv
110 - 195 Kw
350 - 500cv
257- 368 Kw
400 - 700 cv
294,515 Kw
500 - 1000 cv
368 - 736 Kw

10 - 40 cv
7,5 - 30 Kw
25 - 70 cv
7,5 - 30 Kw
110 - 160 cv
81 - 118 Kw
140 - 225 cv
103 - 155 Kw
225 - 400 cv
165 - 2958 Kw
350 - 600 cv
1257 - 440 Kw
400 - 1000 cv
295 - 736 Kw

A 360001

ASS25

25

50

260

200

30

A 360015

ASS38

45

155

365

265

50

A 360003

ASS51

51

97

470

330

70

A 360005

ASS63

63

155

456

396

70

A 360007

ASS89

89

155

850

690

80

A 360010

ASS114 127

205

980

825

80

A 360012

ASS230 152

230

1165

900

132,5

A 360014

ASS320 190

320

1280

1000

140

A 360013

ASS400 220

400

1500

1500

150

FLAME ARRESTOR
PFG flame arrestor is composed by three layers of filtering
grates.
The entire range is delivered with quick lock brackets and reduction rings to adapt to the diameter of the exaust pipe.

Airmeex Code

PFG Type

Tube diameter
mm

A 300001

PFG38

32 - 38,1

A 300002

PFG43

39 - 43,5

A 300003

PFG48

44 - 48,5

A 300004

PFG53

49 - 53,5

A 300005

PFG58

54 - 58,5

A 300006

PFG50

50

A 300007

PFG55

55

A 300008

PFG60

60

A 300009

PFG65

65

A 300010

PFG70

70

A 300011

PFG75

75

A 300012

PFG80

80

A 300013

PFG85

85

A 300014

PFG90

90

A 300015

PFG95

95

A 300016

PFG100

100

A 300017

PFG105

105

A 300018

PFG110

110

A 300019

PFG115

115

A 300020

PFG125

125

A 300021

PFG135

135

STANDARD
SILENCER
ARMEEX study and manufacture all types of silencer, our
product rage is going to 10 KW up to 3000 KW, with different
kind of materials.
All the studies are realized in our office in our bench test.

Our customers are mainly in:


- forklift
- construction machine
- buses and trucks

You might also like