You are on page 1of 38

Bulletin 1494

NEMA Disconnect Switches


Section Overview

Bulletin 1494V
Variable Depth Flange Mounted
Operating Mechanisms
Disconnect Type

Page 2-3

Bulletin 1494V
Variable Depth Flange Mounted
Operating Mechanisms
Circuit Breaker Type

Page 2-7

Bulletin 1494V
Variable Depth Flange Mounted
Remote or Dual Type
Operating Mechanisms
Disconnect Type
Circuit Breaker Type

Page 2-9
Page 2-9

Bulletin 1494F
Fixed-Depth Flange Mounted
Operating Mechanisms
Disconnect Type

Page 2-11

Bulletin 1494F
Fixed-Depth Flange Mounted
Operating Mechanisms
Enclosed Disconnect Type

Page 2-13

Continued on next page.

2-1

Bulletin 1494

NEMA Disconnect Switches


Section Overview, Continued

Bulletin 1494D
Fixed-Depth Flange Mounted
Operating Mechanisms
Circuit Breaker Type

Page 2-15

Bulletin 1494M
Fixed-Depth Remote Operated
Flange Mounted Operating
Mechanisms
Disconnect Type

Page 2-17

Bulletin 1494R
Variable-Depth Door Mounted
Operating Mechanisms
Disconnect Type

Page 2-19

Bulletin 1491
Fuse Blocks
Available from 30A600A

2-2

Page 2-30

Bulletin 1494V

Variable Depth Flange Mounted Operating Mechanisms


Disconnect Type

Bulletin 1494V

To obtain a complete Disconnect Switch,


order the following components:

OR

Fuse Clip Kit

AND

Disconnect Switch
(Auxiliary Contacts Shown
Are Optional)

Operating Handle
Connecting Rod

Trailer Fuse Block Kit

Adaptable to IP65
(Type 1, 3, 3R, 12) or
IP66 (Type 4, 4X)
Disconnect Switches
Available from
30A600A
Highly Visible ON and
OFF Indicator with a
Color Coded Handle
Can Be Used with Class
H, J and R Fuses
Optional Auxiliary
Contacts

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4


Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21

Description

Page

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-27

Description
Bulletin 1494V variable depth flange mounted disconnect switches meet industrial
requirements for dependable manually operated disconnecting means. Operating
handles and disconnecting means are adaptable to IP65 (Type 1, 3, 3R, 12) or IP66
(Type 4, 4X) enclosures with flange-mount construction.

Conformity to Standards:

Approvals:

IEC 947-3

CE Marked Per Low Voltage Directive


73/23/EEC, 93/68/EEC

Cat. No. of the disconnect switch


(fusible or non-fusible).

CSA Certified (File No. LR 1234)

Cat. No. of the operating handle.

UL Listed (File No. E 47426)

Cat. No. of the connecting rod.

CSA C22.2 No. 4


UL 98

Your order must include:

Cat. No. of the trailer fuse block kit.


Cat. No. of the fuse clip kit.
A complete installation consists of a
disconnect switch, an operating
handle, connecting rod, trailer fuse
block kit and fuse clip kit (for
installations that require fusing).
If required, Cat. No. of any
accessories.

2-3

Bulletin 1494V

Variable Depth Flange Mounted Operating Mechanisms


Product Selection
Fusible Disconnect Switch Kits
Includes switch, connecting rod, handle, trailer fuse block and fuse clips
Complete Disconnect Switch Kits for IP65 (Type 1, 3, 3R and 12) Enclosures
IEC Applications
Maximum kW
(AC23)

UL and CSA
Applications
Maximum HP

AC 1
DC
3, 50 Hz
3, 60 Hz
Size 220 380 500
200
(A) 240V 440V 600V 115V 208V 230V 460V 575V 115V 230V 125V 250V

Fuse
Size

30

5.5

11

15

7.5

7.5

15

20

130A

60

11

22

37

7.5

15

15

30

50

10

10

3160A

100

22

45

55

25

30

60

75

20

61100A

200

48

90

110

60

125

150

40

101200A

400

90

185

257

75

125

250

350

50

201400A

600

150

295

375

150

200

400

500

50

401600A

Fuse Fuse
Volt. Clips
250
250
600
600
250
250
600
600
250
250
600
600
250
250
600
600
250
250
600
600
250
250
600
600
600

H
R
H, J
R
H
R
H, J
R
H
R
H, J
R
H
R
H, J
R
H
R
H, J
R
H
R
H
R
J

Cat. No.

1494V-DH233
1494V-DR233
1494V-DH633
1494V-DR633
1494V-DH266
1494V-DR266
1494V-DH666
1494V-DR666
1494V-DH611
1494V-DR611
1494V-DH611
1494V-DR611
1494V-DH622
1494V-DR622
1494V-DH622
1494V-DR622
1494V-DH644
1494V-DR644
1494V-DH644
1494V-DR644
1494V-DH606
1494V-DR606
1494V-DH606
1494V-DR606
1494V-DJ606

Non-Fusible Disconnect Switch Kits


Includes switch, connecting rod, handle (line and load lug connectors located in Accessories section)
Complete Disconnect Switch Kits for IP65 (Type 1, 3, 3R and 12) Enclosures

Size
(A)
30
60
100
200
400
600

IEC Applications
Maximum kW (AC23)

UL and CSA Applications


Maximum HP

3, 50 Hz

3, 60 Hz

220
240V
5.5
11
22
45
90
150

380
440V
11
22
45
90
185
295

500
600V
15
37
55
110
255
375

200
208V
7.5
15
25

75
150

DC

AC1

230V

460V

575V

7.5
15
30
60
125
200

15
30
60
125
250
400

20
40
75
150
350
500

115V 230V 125V 250V


2
3

3
10

3
5

5
10
20
40
50
50

Cat. No.

1494V-DN30
1494V-DN60
1494V-DN100
1494V-DN200
1494V-DN400
1494V-DN600

Ratings based on utilizing 2 poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC supply line.
Long Connecting Rods Disconnect switch kits are also available with a long connecting rod. To order, add the letter L after the letter H,
N or R in the Cat. No.
50 HP at 200V AC; 60HP at 208V AC.
Accessories Page 2-21
Specifications Page 2-25
Approximate Dimensions Page 2-27

2-4

Prices Consult Sales Office or price list

Bulletin 1494V

Variable Depth Flange Mounted Operating Mechanisms


Product Selection, Continued
Disconnect Switches

Maximum Operational Voltage Ue 660V

Size
(A)
30
60
100
200
400
600

IEC Utilization
Category AC-23
Maximum Rating kW

NEMA, UL, CSA


Maximum Rating HP

3, 50 Hz

3, 60 Hz

220
240V
5.5
11
22
45
90
150

380
440V
11
22
45
90
185
295

500
600V
15
37
55
110
257
375

200
208V
7.5
15
25

75
150

230V
7.5
15
30
60
125
200

DC

AC 1

460V
15
30
60
125
250
400

575V
20
50
75
150
350
500

115
2
3

230
3
10

125
3
5

250
5
10
20
40
50
50

Cat. No.
Switch Only
1494V-DS30
1494V-DS60
1494V-DS100
1494V-DS200
1494V-DS400
1494V-DS600

Connecting Rods
Approximate dimensions are in millimeters (inches). Approximate dimensions are not intended for manufacturing purposes.
Disconnect Switch
Size (A)
30, 60, 100, 200

Enclosure Depth
Minimum

Maximum

Cat. No.

172 (6-3/4)

232 (9-1/8)

1494V-RA1

232 (9-1/8)

585 (23)

1494V-RA2

229 (9)

235 (9-1/4)

1494V-RB1

229 (9)

585 (23)

1494V-RB2

400, 600

Operating Handles
Disconnect
Switch

Enclosure Type

Description

Mounting

IP65
(Type 1, 3, 3R, 12)

Painted
Metal

Right or
left flange

30, 60, 100 & 200A 1494V-H1

IP66
(Type 4, 4X)

Stainless
Steel

Right or
left flange

30, 60, 100 & 200A 1494V-W1

IP66
(Type 4, 4X)

Non-Metallic

Right flange only

400A, 600A
400A, 600A

Cat. No.

1494V-H2
1494V-W2

30, 60, 100 & 200A 1494V-R1


400A, 600A

1494V-R2

Also rated operational current for utilization categories AC-20 and AC-21 (IEC 408). For 1 ratings or other AC or DC utilization categories,
consult Allen-Bradley Sales Office.
Ratings based on utilizing 2 poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC supply line.
Devices are field convertible from right hand to left hand flange operation.
Connecting Rods and Operating Handles must be ordered separately.
50 HP at 200V AC; 60 HP at 208V AC.
Enclosure depth is measured from the top of the flange to the disconnect means mounting surface (mm).
Two per installation required.

Accessories Page 2-21


Specifications Page 2-25
Approximate Dimensions Page 2-27

Prices Consult Sales Office or price list

2-5

Bulletin 1494V

Variable Depth Flange Mounted Operating Mechanisms


Product Selection, Continued
Fuse Clip Kits
Includes six clips and mounting hardware
Fuse Clip Rating (A)
Fuse Class

250V

600V

30

1401-N41

H, J

60

30

1401-N42

H, J

60

1401-N43

H, J

100

100

1401-N44

H, J

200

200

1401-N45

H, J

400

400

1401-N46

Cat. No.

Trailer Fuse Block Kits


For Class H and J fuses, select the proper fuse clip kit from the table above. For UL Class R fuse applications, non-removable
rejection type clips are mounted on the trailer fuse block at the factory. Three additional clips are included for mounting on the
disconnect switch.
UL Class C, H and J

UL Class R
Fuse Size (A)

Disconnect
Size (A)

Fuse
Size (A)

30

Cat. No.

250V

600V

1494V-FS30

30

1494V-FSR233

3160

1494V-FS63

30

1494V-FSR633

30

1494V-FSR636

60

1494V-FS60

60

1494V-FSR266

61100

1494V-FS16

60

1494V-FSR666

60

1494V-FSR661
1494V-FSR611

61100

1494V-FS100

100

100

101200

1494V-FS21

100

1494V-FSR612
1494V-FSR622

200

1494V-FS200

200

200

201400

1494V-FS42

200

1494V-FSR624

400

400

1494V-FSR644

1494V-FS400

201400
Class H

600

101200

400

Cat. No.

3160

100

030

Class J

401600

1491-N621

401600

1494V-FS600

600

600

1491-R621

Not required when installing 201 through 400A fuses on the 200A disconnect switch, Cat. No. 1494V-DS200.
Down Fusing For all Class H and J applications, order the Trailer Fuse Block kit for the size disconnect being used and order the lower
ampacity Fuse Clip Kit. Note: The 100A disconnect size requires that an Adapter Kit, Cat. No. 1401-N170 also be ordered. For Class R
applications, refer to the trailer fuse block kit table above for listed devices.
For use with Class J fuses only.
Single Pole Fuse Block 3 required per installation.

Accessories Page 2-21


Specifications Page 2-25
Approximate Dimensions Page 2-27

2-6

Prices Consult Sales Office or price list

Bulletin 1494V

Variable Depth Flange Mounted Operating Mechanisms


2

Circuit Breaker Type

To obtain a complete Operating Mechanism,


order the following components:

OR

Bulletin 1494V

Circuit Breaker Operating Mechanism


(Circuit Breaker is Shown But Not Supplied
With Operating Mechanisms)

Operating Handle

Adaptable to
IP65 (Type 1, 3, 3R, 12)
or IP66 (Type 4, 4X)
Enclosures
Circuit Breaker
Operating Mechanisms
Available 150A400A
Frame Breakers
Highly Visible ON and
OFF Indicator with a
Color Coded Handle
Optional Auxiliary
Contacts

Connecting Rod

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8


Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21

Description

Page

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-27

Description
Bulletin 1494V variable depth flange mounted disconnect switches meet industrial
requirements for dependable manually operated disconnecting means. Operating
handles and disconnecting means are adaptable to IP65 (Type 1, 3, 3R, 12) or IP66
(Type 4, 4X) enclosures with flange-mount construction.

Conformity to Standards:

Approvals:

IEC 947-3

CSA Certified (File No. LR 1234)

Cat. No. of the circuit breaker.

CSA C22.2 No. 4

UL Listed (File No. E 47426)

Cat. No. of the operating handle.

UL 98

Your order must include:

Cat. No. of the connecting rod.


A complete installation consists of a
circuit breaker, an operating handle,
and connecting rod.
If required, Cat. No. of any
accessories.

2-7

Bulletin 1494V

Variable Depth Flange Mounted Operating Mechanisms


Product Selection
Circuit Breaker Type, Continued
Circuit Breaker Operating Mechanism The mechanism listed must be combined with a connecting rod, operating handle and
circuit breaker to obtain a functional device.
3-Pole Circuit Breaker
Manufacturer

Size (A)

Cutler-Hammer/
Westinghouse

150

Cutler-Hammer/
Westinghouse

Operating Mechanism
Right Hand
Cat. No.

Frame Designation
EHD, FD, FDB, FDC,
HFD, HMCP
JD, JDB, JDC,
HJD, HMCP
KD, KDB, KDC,
HKD, HMCP

250
400

Left Hand
Cat. No.

1494V-M40

1494V-M40

1494V-M50

1494V-M50

1494V-M60

1494V-M60

Connecting Rods
Approximate dimensions are in millimeters (inches). Approximate dimensions are not intended for manufacturing purposes.
Circuit Breaker
Frame Size (A)
150, 250 and 400

Enclosure Depth
Minimum

Maximum

172 (6-3/4)
232 (9-1/8)

232 (9-1/8)
585 (23)

Mounting

Circuit Breaker
Frame Size (A)

Cat. No.
1494V-RA1
1494V-RA2

Operating Handle

Enclosure Type
IP65 (Type 1, 3R, 3 and 12)
IP66 (Type 4, 4X Metallic)

Right or
Left Flange
Right or
Left Flange

Operating Handle
Cat. No.

150, 250 & 400

1494V-H11

150, 250 & 400

1494V-W11

Circuit breakers to be provided by user.

Accessories Page 2-21


Specifications Page 2-26
Approximate Dimensions Page 2-27

2-8

Prices Consult Sales Office or price list

Bulletin 1494V

Variable Depth Flange Mounted Operating Mechanisms


Remote or Dual Type

Bulletin 1494V

Remote Drive
Operating Mechanism

Main Drive Dual


Operating Mechanism
(Includes Operating Handle)

Adaptable to IP65
(Type 1, 3, 3R, 12) or
IP66 (Type 4, 4X)
Enclosures
Disconnect Switches
Available from
30A600A
Highly Visible ON and
OFF Indicator with
Color Coded Handle
For Use with Disconnect
Switches or Circuit
Breaker

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10


Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21

Description

Page

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-27

Description
Remote Handling Mechanisms Allow the operating handle to be mounted either
above or below the disconnect means.
Dual Operating Mechanisms Permit the control of two disconnect means utilizing
a common operating handle.
Operation Both the Remote and Dual Operating Mechanisms consist of two
components a main drive mechanism (which includes the operating handle) and
a remote drive mechanism. To obtain a functional device, these components must
be properly combined with a connecting link (supplied by customer), disconnect
means and connecting rod.

Conformity to Standards:

Approvals:

IEC 947-3

CSA Certified (File No. LR 1234)

CSA C22.2 No. 4

UL Listed (File No. E 47426)

UL 98

Your order must include:


Cat. No. of the remote driver or main
drive dual operating mechanism.
If required, Cat. No. of any
accessories.

2-9

Bulletin 1494V

Variable Depth Flange Mounted Operating Mechanisms


Product Selection
Remote or Dual Type, Continued
Remote or Dual Operated Mechanisms Separate Components
Size
Type of
Mechanism

Enclosure
Type

Disconnect Switch
30A, 60A, 100A &
200A

400A, 600A

Cutler-Hammer/
Westinghouse
150A, 250A & 400A
EHD, FD, FDB, FDC,
HFD, HMCP, JD, JDB,
JDC, HJD, KD, KDB,
KDC, HKD

IP65
(Type 1, 3, 3R
and 12)

Remote

30A, 60A, 100A &


200A

400A, 600A

Cutler-Hammer/
Westinghouse
150A, 250A & 400A
EHD, FD, FDB, FDC,
HFD, HMCP, JD, JDB,
JDC, HJD, KD, KDB,
KDC, HKD

IP66
(Type 4)

IP65
(Type 1, 3, 3R
and 12)

Circuit
Breaker

Two 30A, Two 60A,


Two 100A or any
Combination of Two
30A through 100A
Switches

Cutler-Hammer/
Westinghouse
Two 150A
EHD, FD, FDB, FDC,
HFD, HMCP

Mounting

Cat. No.

Right
Left
Right
Left

1494V-H5
1494V-HL5
1494V-H8
1494V-HL8

Right

1494V-H10

Left

1494V-HL10

Right
Left
Right
Left

1494V-W5
1494V-WL5
1494V-W8
1494V-WL8

Right

1494V-W10

Left

1494V-WL10

Right

1494V-H50

Left

1494V-HL50

Right

1494V-H95

Left

1494V-HL95

Right

1494V-W50

Left

1494V-WL50

Right

1494V-W95

Left

1494V-WL95

Dual

IP66
(Type 4)

Two 30A, Two 60A,


Two 100A or any
Combination of Two
30A through 100A
Switches

Cutler-Hammer/
Westinghouse
Two 150A
EHD, FD, FDB, FDC,
HFD, HMCP

Includes Main and Remote Drive Mechanisms. Does not include rectangular bar stock (1/4-inch) 6.35mm x (5/8-inch) 15.8mm connecting bar
between disconnecting means and connecting rod, to be supplied by user.

Accessories Page 2-21


Specifications Page 2-25
Approximate Dimensions Page 2-27

2-10

Prices Consult Sales Office or price list

Bulletin 1494F

Fixed-Depth Flange Mounted Operating Mechanisms


Disconnect Type

To obtain a complete Fusible Disconnect Switch,


order the following components:

Bulletin 1494F

Cat. No. 1494F-NF30


Disconnect Switch and
Operating Mechanism

Cat. No. 1494F-J633


Fuse Block Adapter Plate Kit
With Fuse Clips

Adaptable to All
IP42 (Type 1) and IP65
(Type 12) Enclosures
with Right or Left Hand
Flange Construction
Disconnect Switch
Available from
30A200A
Highly Visible ON and
OFF Indicator
Can Be Used with Class
H, J and R Fuses
Optional Auxiliary
Contacts

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12


Disconnect Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
Enclosed Disconnect Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13

Description

Page

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-28

Description
Bulletin 1494F Fixed-Depth Flange Mounted Disconnect Switches meet industrial
requirements for a dependable manually operated disconnecting means. The Fusible
Disconnect Switch Assembly is made up of two components a Disconnect Switch
and Operating Mechanism and a Fuse Block Adapter Kit, with fuse clips.

Conformity to Standards:

Approvals:

IEC 947-3

CE Marked Per Low Voltage Directive


73/23/EEC, 93/68/EEC

Cat. No. of the disconnect switch


fusible or non-fusible.

CSA Certified (File No. LR 1234)

Cat. No. of the Fuse Block Adapter


Plate Kit with fuse clips.

CSA C22.2 No. 4


UL 98

Your order must include:

UL Listed (File No. E 47426)


To obtain a complete fusible
disconnect switch the above items
must be on your order.
Accessories, if necessary.

2-11

Bulletin 1494F

Fixed-Depth Flange Mounted Operating Mechanisms


Product Selection
Fusible Disconnect Switch Kits
Includes switch, operating mechanism and handle (line and load lug connectors located in the Accessories section on
page 2-22). To obtain a complete fusible disconnect switch, select the proper Fuse Block Adapter Plate Kit with fuse clips from
the table below.
Disconnect Switches for IP42 (Type 1) and IP65 (Type 12) Enclosures

IEC Applications
Maximum kW (AC23)

UL and CSA Applications


Maximum HP

3, 50 Hz

3, 60 Hz

Open Type
Without Enclosure
Flange Construction
DC

AC 1

Right Hand

Size
(A)

220
240V

380
440V

500
600V

200
208V

230V

460V

575V

115V

230V

125V

250V

30
60
100
200

5.5
11
22
45

11
22
45
75

15
30
55
75

7.5
15
30
60

7.5
15
30
60

15
30
60
100

20
40
75
100

2
3

3
10

3
5
10
20

5
10
20
40

Cat. No.
1494F-NF30
1494F-NF60
1494F-NF100
1494F-NF200

Left Hand
Cat. No.

1494F-NFL30
1494F-NFL60
1494F-NFL100
1494F-NFL200

Non-Fusible Disconnect Switch Kits


Includes switch, operating mechanism, and handle (line and load lug connectors located in the Accessories section on page 2-21).
Disconnect Switches for IP42 (Type 1) and IP65 (Type 12) Enclosures
IEC Applications
Maximum kW (AC23)

UL and CSA Applications


Maximum HP

Open Type
Without Enclosure
Flange Construction

3 50 Hz

3, 60 Hz

DC

AC 1

Right Hand

Size
(A)

220
240V

380
440V

500
600V

200
208V

230V

460V

575V

115V

230V

125V

250V

30
60
100
200

5.5
11
22
48

11
22
45
90

15
37
55
110

7.5
15
30
60

7.5
15
30
60

15
30
60
100

20
40
75
100

2
3

3
10

3
5
10
20

5
10
20
40

Cat. No.
1494F-N30
1494F-N60
1494F-N100
1494F-N200

Left Hand
Cat. No.

1494F-NL30
1494F-NL60
1494F-NL100
1494F-NL200

Fuse Block Adapter Plate Kits with Fuse Clips


UL Class R Dimension
Disconnect
Size (A)
30
60
100
200

250V

Fuse
Clips

Cat. No.

30
60
30
60
100
100
200
200
400

1494F-R233
1494F-R263

1494F-R266
1494F-R216
1494F-R211
1494F-R221
1494F-R222
1494F-R242

600V

Cat. No.
1494F-R633
1494F-R663
1494F-R636
1494F-R666
1494F-R616
1494F-R611
1494F-R621
1494F-R622
1494F-R642

UL Class J Dimension

Class H and C

600V

600V

Cat. No.
1494F-J633
1494F-J663

1494F-J666
1494F-J616
1494F-J611
1494F-J621
1494F-J622
1494F-J642

Cat. No.

1494F-C633
1494F-C663
1494F-C636
1494F-C666
1494F-C616
1494F-C611
1494F-C621
1494F-C622
1494F-C642

Does not include rectangular bar stock 6.35mm (1/4 in.) x 15.8mm (5/8 in.) connecting bar between switch and remote operating mechanism
and handle to be provided by user.
Ratings based on utilizing 2 poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC supply line.

Accessories Page 2-21


Specifications Page 2-25
Approximate Dimensions Page 2-28

2-12

Prices Consult Sales Office or price list

Bulletin 1494F

Flange Mounted Operating Mechanisms


Disconnect Type

Bulletin 1494F
Non-Fusible Disconnect
Switch Available in Sizes:
30, 60, 100, 200 and 400A
Enclosure Rating Type
3/3R/4/12 Painted Steel
Rugged Quick-Make,
Quick-Break Snap Action
Switch with Visible
Blade Construction
Durable Flange Mounted,
Non-Metallic, Color Coded
Handle for Easy ON or
OFF Identification
Optional Push Buttons
and Pilot Lights
Disconnect Switch
Padlocking Capability to
Meet OSHA
External Mounting Feet
Enclosure Padlocking
Capability
Line Side, Load Side and
Ground Terminal Lugs
Provided

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14


Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21
Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-24

Description

Page

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-29

Description
Bulletin 1494F line of NEMA enclosed disconnect switches are compact in size, but
ruggedly designed for long lasting performance. These switches are ideal for use as:
At Motor disconnect
Main safety switch

Your order must include:


Conformity to Standards:

Approvals:

UL 98

UL Listed (File No. E 14841)

CSA C22.2 No. 4


IEC 947-3

Cat. No. of the disconnect switch


(fusible or non-fusible).
Cat. No. of the Fuse Block Adapter
Plate Kit with fuse clips.
To obtain a complete fusible
disconnect switch the above items
must be on your order.
Accessories, if necessary.

2-13

Bulletin 1494F

Flange Mounted Operating Mechanisms


Product Selection Modifications
Non-Fusible Disconnect Switch
IP65 (Type 3, 3R, 4, 12)
Painted Steel

Maximum HP
3, 60 Hz

1 60 Hz

Size
(A)

200 208V

230V

460V

575V

115V

230V

Dim Ref.

30
60
100
200
400

7.5
15
25
50
100

7.5
15
30
60
125

15
30
50
125
250

20
40
50
150
350

2
3

3
10

A11
A12
A12
A13
A14

Cat. No.
1494F-FNP30
1494F-FNP60
1494F-FNP100
1494F-FNP200
1494F-FNP400

Accessories Page 2-21


Modifications Page 2-24
Specifications Page 2-25
Approximate Dimensions Page 2-29

2-14

IP66 (Type 4, 4X)


Stainless Steel

Prices Consult Sales Office or price list

Cat. No.
1494F-CNP30
1494F-CNP60
1494F-CNP100
1494F-CNP200
1494F-CNP400

Bulletin 1494D

Fixed-Depth Flange Mounted Operating Mechanisms


Circuit Breaker Type

To obtain a complete operating mechanism, order an


Operating Mechanism and Slide or Bail Mechanism.

Bulletin 1494D
Adaptable to Both
IP42 (Type 1) and IP65
(Type 12) Enclosures
with Right Hand Flange
Construction
Circuit Breaker
Operating Mechanisms
Available From
150A1200A Frame
Sizes
Highly Visible ON and
OFF Indicator
Optional Auxiliary
Contacts
Cat. No. 1494D-N4 and Cat. No. 1494D-N40
(Circuit Breaker Not Included. Auxiliary Contact and
Adapter Kit Must Be Ordered Separately)

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16


Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21

Description

Page

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-28

Description
Bulletin 1494D Fixed Depth Circuit Breaker Operating Mechanisms are designed to
operate commonly used molded case circuit breakers (which are to be supplied by
the user).

Conformity to Standards:

Approvals:

IEC 947-3

CSA Certified (File No. LR 1234)

Cat. No. of the operating mechanism.

CSA C22.2 No. 4

UL Listed (File No. E 47426)

Cat. No. of the slide or bail mechanism.

UL 98

Your order must include:

Cat. No. of any accessories, if


required.
An operating mechanism and a slide or
bail mechanism must be combined
with the proper circuit breaker in order
to obtain a functional device.

2-15

Bulletin 1494D

Fixed-Depth Flange Mounted Operating Mechanisms


Product Selection
Circuit Breaker Type
Operator Mechanism and Slide/Bail Mechanisms Complete Operating Mechanism
3 Pole Circuit Breaker

Operator

Frame
Size (A)

Frame Designation

Cutler-Hammer/
Westinghouse

150

EHD, FD, FDB, FDC, HFD, HMCP

Cutler-Hammer/
Westinghouse

250
400
600
800
800
1200

JD, JDB, JDC, HJD, HMCP


KD, KDB, KDC, HKD, HMCP
LA, HLA, LC, HLC, LD, HLD
MA, HMA, MC, ND, HND, NDC
NB Tri-Pac
NB, HNB, NC, HNC, ND, HND, NDC

Manufacturer

Cat. No.
1494D-N4
1494D-N5

1494D-N3

Circuit breakers to be provided by user.

Accessories Page 2-21


Specification Page 2-26
Approximate Dimensions Page 2-28

2-16

Prices Consult Sales Office or price list

Slide or Bail

Cat. No.
1494D-N40
1494D-N50
1494D-N60
1494D-N31
1494D-N41
1494D-N41T
1494D-N43

Bulletin 1494M

Fixed-Depth Remote Operated Flange Mounted Operating Mechanisms


Disconnect Type

Bulletin 1494M

Right Hand Flange


Mounted, Remote
Operated, Non-Fusible Disconnect
Switch and Operating
Mechanism

Adaptable to Both
IP42 (Type 1) and IP65
(Type 12) Enclosures
with Right or Left Hand
Flange Construction
Disconnect Switches
Available up to 200A
Highly Visible ON and
OFF Indicator

TABLE OF CONTENTS
Description

Page

Product Specification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18


Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21

Description

Page

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-28

Description
The disconnect switch is made up to two units the basic switch and the operating
mechanism. These two units must be properly combined with a connecting bar to
obtain a functional device. This method allows the user to determine specific
distances required between the disconnect switch and the operating mechanism.
This feature is often required when the enclosure is to be mounted high off the floor
making a conventional device difficult for personnel to operate. Note: The operating
mechanism can only be mounted below the switch.

Conformity to Standards:
IEC 947-3

Your order must include:

CSA C22.2 No. 4

Cat. No. of the disconnect switch


(fusible or non-fusible).

UL 98

Accessories, if necessary.

2-17

Bulletin 1494M

Fixed-Depth Remote Operated Flange Mounted Operating Mechanisms


Product Selection
Fusible Disconnect Kits
Includes switch, fuse block adapter plate, fuse clips, operating mechanism and handle (line and load lug connectors located in
the Accessories section on page 2-22).
Complete Disconnect Switch Kit for IP42 (Type 1) and IP65 (Type 12)
IEC Applications
Maximum kW (AC23)

UL and CSA Applications


Maximum HP

3, 50 Hz

3, 60 Hz

Open Type
Without Enclosure
Flange Construction
DC

AC 1

Right Hand

Left Hand

Size
(A)

220
240V

380
440V

500
600V

200
208V

230V

460V

575V

115V

230V

125V

250V

Cat. No.

Cat. No.

30

5.5

11

15

7.5

7.5

15

20

1494M-NF30

1494M-NFL30

60

11

22

30

15

15

30

40

10

10

1494M-NF60

1494M-NFL60

100

22

45

55

30

30

60

75

10

20

1494M-NF100

1494M-NFL100

200

45

75

75

60

60

100

100

20

40

1494M-NF200

1494M-NFL200

Non-Fusible Disconnect Kits


Includes switch, operating mechanism and handle (line and load lug connectors located in the Accessories section on page 2-22).
Complete Disconnect Switch Kit for IP42 (Type 1) and IP65 (Type 12)
IEC Applications
Maximum kW (AC23)

UL and CSA Applications


Maximum HP

Open Type
Without Enclosure
Flange Construction

3, 50 Hz

3, 60 Hz

DC

AC 1

Right Hand

Left Hand

Size
(A)

220
240V

380
440V

500
600V

200
208V

230V

460V

575V

115V

230V

125V

250V

30

5.5

11

15

7.5

7.5

15

20

1494M-N30

1494M-NL30

Cat. No.

Cat. No.

60

11

22

37

15

15

30

50

10

10

1494M-N60

1494M-NL60

100

22

45

55

30

30

60

75

10

20

1494M-N100

1494M-NL100

200

48

90

110

60

60

100

100

20

40

1494M-N200

1494M-NL200

Fuse Block Adapter Plate Kits with Fuse Clips


UL Class R Dimension
250V

600V

UL Class J Dimension

Class H and C

600V

600V

Disconnect
Size (A)

Fuse
Clips

Cat. No.

30

30
60

1494F-R233
1494F-R263

1494F-R633
1494F-R663

1494F-J633
1494F-J663

1494F-C633
1494F-C663

60

30
60
100

1494F-R266
1494F-R216

1494F-R636
1494F-R666
1494F-R616

1494F-J666
1494F-J616

1494F-C636
1494F-C666
1494F-C616

100

100
200

1494F-R211
1494F-R221

1494F-R611
1494F-R621

1494F-J611
1494F-J621

1494F-C611
1494F-C621

200

200
400

1494F-R222
1494F-R242

1494F-R622
1494F-R642

1494F-J622
1494F-J642

1494F-C622
1494F-C642

Cat. No.

Cat. No.

Cat. No.

Does not include rectangular bar stock 6.35mm (1/4 in.) x 15.8mm (5/8 in.) connecting bar between switch and remote operating mechanism
and handle to be provided by user.
Ratings based on utilizing 2 poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC supply line.

Accessories Page 2-21


Specifications Page 2-25
Approximate Dimensions Page 2-28

2-18

Prices Consult Sales Office or price list

Bulletin 1494R

Variable Depth Door Mounted Operating Mechanisms


Disconnect Type

To obtain a complete Disconnect Switch Kit, order the following:

Disconnect Switch
(Auxiliary Contact Shown is Optional)

Bulletin 1494R

Operating
Handle

Connecting
Rod and
Hitch Pin

Cat. No. 1494R-N30

Adaptable to Both
IP42 (Type 1) and IP65
(Type 12) Enclosures
Disconnect Switches
Available from
30A200A
Highly Visible ON,
OFF and Open
Indicator
Can Be Used with Class
H (Bulletin 1491 Fuse
Block Kits), J and R
Fuses

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20


Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21

Description

Page

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25

Description
Bulletin 1494R rod operated disconnect switch is applicable to both IP42 (Type 1)
and manual type disconnect device. The complete Disconnect Switch consists of the
disconnect switch, operating handle, connecting rod and hitch pin.

Conformity to Standards:

Approvals:

IEC 947-3

CSA Certified (File No. LR 1234)

Cat. No. of the disconnect switch.

CSA C22.2 No. 4

UL Listed (File No. E 47418)

If necessary, Cat. No. of any


accessories.

UL 98

Your order must include:

2-19

Bulletin 1494R

Variable Depth Door Mounted Operating Mechanisms


Product Selection
Disconnect Switch Kits
Includes switch, operating handle, connecting rod and hitch pin (line and load lug connectors located in the Accessories section
on page 2-22).

Complete Non-Fused Disconnect Switch Kits for IP42 (Type 1) and IP65 (Type 12) Enclosures

Size
(A)
30
60
100
200

IEC Applications
Maximum kW (AC23)

UL and CSA Applications


Maximum HP

3, 50 Hz

3, 60 Hz

220 240V 280 440V 500 600V 200 208V


5.8
11
22
45

11
22
45
90

15
37
55
110

7.5
15
30
60

230V

460V

575V

7.5
15
30
60

15
30
60
125

20
40
75
150

Open Type
Without Enclosure

AC 1

DC

115V 230V

150V

Cat. No.

3
5
10

1494R-N30
1494R-N60
1494R-N100
1494R-N200

2
3

3
10

Longer Shafts Approximate dimensions are in mm (inches)


The standard lengths for shafts furnished with the disconnect switches are 241.3 (9-1/2) on the 30A and 60A and 279.4 (11) on the
100A and 200A. Longer shafts are available and must be ordered separately. Approximate dimensions are not intended for
manufacturing purposes.
Shaft Kits
Disconnect Switch
Size (A)

Length

Cat. No.

30
60
100
200

457.2 (18)
457.2 (18)
609.6 (24)
609.6 (24)

1494R-N4
1494R-N4
1494R-N5
1494R-N6

Ratings based on utilizing 2 poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC supply line.
To obtain a fusible disconnect switch, add Bulletin 1491 fuse blocks. See page 2-30.

Accessories Page 2-21


Specifications Page 2-25

2-20

Prices Consult Sales Office or price list

Bulletin 1494

Accessories Field Installed


Accessories

Description
Auxiliary Contacts
1 N.O. Contact
Auxiliary Contacts
1 N.C. Contact

Cat. No.
1495-N21

Cat. No.
1495-N23

Cat. No. 595-A

Cat. No. 595-B

Cat. No. 895-A1

Cat. No. 895-M11

Cat. No. 895-A2

Cat. No. 895-M21

Cat. No.
1495-N30

Cat. No.
1495-N31

Auxiliary Contact Adapter Kit


150A Frame Cutler-Hammer/Westinghouse
Auxiliary Contact Adapter Kit
250A Frame Cutler-Hammer/Westinghouse
Auxiliary Contact Adapter Kit
400A Frame Cutler-Hammer/Westinghouse
Auxiliary Contact Adapter Kit
600A, 800A, 1200A Frame Cutler-Hammer/Westinghouse
Auxiliary Contact Adapter Kit
250A and 400A Frame Cutler-Hammer/Westinghouse

Cat. No.
1494F-N33

Cat. No.
1494F, 1494M
1495-N8
Disconnect Switch
1494D, 1494V
Circuit Breaker
1494D, 1494V
Circuit Breaker
1494D, 1494V
Circuit Breaker
1494D, 1494V
Circuit Breaker
1494D, 1494V
Circuit Breaker
1494V
Circuit Breaker

1495-N21
1495-N22
1495-N16
1495-N13
1495-N23

1494V
595-A
Disconnect Switch

Auxiliary Contacts
1 N.C. Contact

1494V
595-B
Disconnect Switch

Auxiliary Contact Adapter Kit


400A and 600A Disconnect

1494V
595-N1
Disconnect Switch

Auxiliary Contacts
1 N.O. Contact
Auxiliary Contacts
1 N.C. Contact
Auxiliary Contacts
1 N.O. and 1 N.C. Contact
Auxiliary Contact Adapter Kit
for 1 contact
Auxiliary Contact Adapter Kit
for 2 contacts
Auxiliary Contacts
1 N.O. Contact
Auxiliary Contacts
1 N.C. Contact
Auxiliary Contacts
1 N.O. and 1 N.C. Contact
Auxiliary Contact Adapter Kit
for 1 contact
Auxiliary Contact Adapter Kit
for 2 contacts
Auxiliary Contact
1 N.O. Contact
Auxiliary Contact
1 N.C. Contact

Auxiliary Contact
1 N.O. Contact and 1 N.C. Contact early break

1495-N9

Auxiliary Contacts
1 N.O. Contact

Auxiliary Contact Adapter Kit


(for a maximum of 2 contacts)
Cat. No.
1495-N32

For use with


Cat. No.

895-A1

1494R
Disconnect
Switch
30, 60A

895-B1
895-C1
895-M11
895-M12
895-A2

1494R
Disconnect
Switch
100, 200A

895-B2
895-C2
895-M21
895-M22
1495-N30

1494F
Enclosed
Disconnects
Only

1495-N31
1495-N32
1495-N33

Requires an adapter kit on new installations.


One auxiliary contact adapter kit enables up to two auxiliary contacts to be installed.
Required on new installations only.

Prices Consult Sales Office or price list

2-21

Bulletin 1494

Accessories Field Installed


Accessories, Continued

For use with


Cat. No.

Description

Cat. No. 1494R-N3

Lug Connectors (3 per package)


Disconnect
Wire Size
Size (A)
30
#14#8 AWG Wire
60
#14#4 AWG Wire
100
#8#1/0 AWG Wire
200
#6#4/0 AWG Wire
400600
2 of #110350 MCM Wire

Defeater Bracket Extension Kit


For use with operating handles that do not align properly
with the door catch or door hardware on enclosures with a
rolled lip flange construction.

Alternate Mounting Kits


For use where the flange material thickness is greater than
4.8mm (3/16 in.).

1494V, 1494F,
1494M, 1494R
Disconnect
Switches

Cat. No.

1494R-N1
1494R-N2
1494R-N3
1494R-N10

All 1494V handles


(except 1494V-R1 1494V-H12
and 1494V-R2)

Operating handles
1494V-H1 or
1494V-H3
1494V-H11
Operating Handles 1494V-H2

1494V-H6

Cat. No. 1494R-H3

Applies only to
operating handle
Channel Support Kits
Cat. Nos. 1494VFor use to prevent flexing of the operating handle mounting
H1, W1, H11 and 1494V-H4
surface. This is especially useful when the operating handle
W11 (does not
is mounted on a channel in a multi-door enclosure.
apply to dual or
remote operators).
All terminals of the 30A switches are furnished with self-lifting pressure plate connectors as standard.

2-22

Prices Consult Sales Office or price list

Bulletin 1494

Accessories Field Installed


Accessories, Continued

Description
Type 12 Door Hardware Kit includes:
handle, cam, defeater actuator lever, rollers and shims.
Enclosure heights 762mm (30 in.) and less
Top and Side (Right Hand)
Top and Side (Left Hand)
Top and Bottom (Right Hand)
Top and Bottom (Left Hand)
Enclosure Heights 762mm (30 in.) to 1219mm (48 in.)
Top, Side and Bottom (Right Hand)

For use with


Cat. No.

1494F-L1
1494F-LL1
1494F-L2
1494F-LL2
1494F,
1494M,
1494D

1494F-L2 and
1494F-L3
1494F-LL2 and
1494F-L3

Top, Side and Bottom (Left Hand)

Door Hardware Kit Showing


Top, Side and
Bottom Latching

Cat. No.

Enclosure Heights greater than 1219mm (48 in.)


Top, Side and Bottom (Right Hand)

1494F-L4

Top, Side and Bottom (Left Hand)

1494F-LL4

Enclosure Heights 1016mm (40 in.) and less


Top and Side (Right Hand)

1494V-L1

Top and Side (Left Hand)

1494V-LL1

Enclosure Heights 1016mm (40 in.) to 1529mm (60 in.)


Top, Side and Bottom (Right Hand)
All 1494V
Top, Side and Bottom (Left Hand)

1494V-L1 and
1494V-L2
1494V-LL1 and
1494V-L2

Enclosure Heights 1524 (60 in.) and greater


Top, Side and Bottom (Right Hand)
Cat. No. 1494V-L1

1494V-L3

Cat. No. 1494V-L3 Top, Side and Bottom (Left Hand)

Cat. No. 1494F-N20

Multiple Door Interlock Kits


Interlock kits are designed to provide interlocking between
the master and auxiliary doors of the same enclosure and
for use with Cat. Nos. 1494F-L4 and 1494F-LL4 hardware
kits or 1494V-L3 and 1494V-LL3 hardware kits. Specify one
master door kit and as many auxiliary door kits as
necessary (9 maximum). Connecting bars must be supplied
by user.
Master Door Interlock Kit
Auxiliary Door Interlock Kit
Conduit Hubs (non-metallic)
12.7mm (1/2 in.)

1494V-L3

1494F,
1494M,
1494D,
1494V
1494F-N20
1494F-N21
1490-N1
1490-N9

19mm (3/4 in.)


25.4mm (1 in.)
31.75mm (1-1/4 in.)
38.1mm (1-1/2 in.)

1490-N10
1494F
Enclosed
Disconnects
Only

1490-N11
1490-N5

50.8mm (2 in.)

1490-N6

63.5mm (2-1/2 in.)

1490-N7

76.2mm (3 in.)

1490-N8

Cat. No. 1490-N11

Prices Consult Sales Office or price list

2-23

Bulletin 1494

Modifications Factory Installed


Modifications
2

Bulletin 1494F Enclosed Disconnect Switches


For use with
Cat. No.

Description
Signal Push Button (1 N.O.)
Red Pilot Light
Green Pilot Light
Red Push to Test Pilot Light
Auxiliary Contact (1 N.O.)
Auxiliary Contact (1 N.C.)
Enclosure Door Viewing Window

1494F
Enclosed
Disconnects
Only

Only one push button or pilot light may be added to a Bulletin 1494F Disconnect Switch.
A maximum of two auxiliary contacts may be added to a Bulletin 1494F Disconnect Switch.

2-24

Prices Consult Sales Office or price list

Suffix Code
-1S
-4R
-4G
-5R
-98
-99
-203W

Bulletin 1494

Disconnect Switches
Specifications

1494F Disconnect, 1494M Remote Type, 1494V Disconnect Type,


1494V Remote or Dual Type, 1494R Disconnect Type
Frame Size

Electrical Ratings

250A

150A

Auxiliary Contacts
IEC Ratings

Ith

10A

Ui

660V

ACII

Ux

400A

12120V
220240V
380400V
500600V

ACII

30A

60A

100A

220240V/50 Hz
380/440V/50 Hz
500600V/50 Hz

5.5
11
15

11
22
37

230V/60 Hz
460V/60 Hz
575V/60 Hz

7.5
15
20

15
30
50

EEMAC/NEMA

Ie

6A
3A
1.5A
1.2A

B600, P300

Switch Size

200A

400A

600A

22
45
55

45
90
110

90
185
257

135
275
420

30
60
75

60
125
150

125
250
350

250
500
750

Rated insulation voltage Ui (UL) IEC

HP

Auxiliary Contacts

AC11

DC11

[]

Make or Break

360VA

EEMAC/NEMA

[]

360VA

[]

Make or Break

Ratings:
Ue 600V AC
600V DC

[]

Ratings:
CSA/NEMA/UL

kW

(600) 660V

Contacts IEC 408


AC-23 rating

138VA 138VA

A600, P300

Mechanical
Degree of protection

Operating handles:

IP65 (Types 1, 3, 3R, and 12), IP66 (Types 4, 4x)

Mechanical life (Typical)

20,000 operations

Switching frequency (operations/hr)

30A, 60A, 100A and 200A sizes 300 maximum

400A and 600A size 240 Maximum

Environmental
Temperature

Operating
Storage

5C+40C (+41F104F)
30C+65C (22F149F)

Altitude

2000m per IEC 337-1

Design Specification/Test Requirements


Dielectric strength

2500V for 1 minute

Electrical life

6000 operations at rated current

Construction
Switch body material

Phenolic

Contact material

Copper, tinplated

Terminals:

Cable Size (mm2)

Recommended Torque:

30A
60A
100A
200A
400A
600A
30A
60A
100A
200A
400A, 600A
30A
60A
100A
200A
400A
600A

#10 - 32 screw and self-lifting pressure plate


1/4 - 28 screw-lug, copper alloy
5/16 - 24 screw-lug, copper alloy
3/8 - 24 screw-lug, copper alloy
1/2 - 24 screw-lug, copper alloy
5/8 - 22 screw-lug, copper alloy
1.510mm2 (#14#8 AWG)
2.516mm2(#14#4 AWG)
1050mm2 (#8#1/0 AWG)
1695mm2 (#6#4/0 AWG)
350 MCM - 185mm2 (2 of #1/0 AWG) (2 per lug)
20 lb-in.
45 lb-in.
150 lb-in.
275 lb-in.
400 lb-in.
575 lb-in.

Construction
Mechanisms

Zinc Plated Steel

Handles

Steel, painted

2-25

Bulletin 1494

Circuit Breaker Type Operating Mechanisms


Specifications, Continued
2

1494D Circuit Breaker Type, 1494V Circuit Breaker Type


Frame Size
150A

Electrical Ratings
Auxiliary Contacts
IEC Ratings

Ith

10A

Ui

660V

ACII

Ux

250A

400A

12120V
220240V
380400V
500600V

EEMAC/NEMA

ACII

Ie

6A
3A
1.5A
1.2A

B600, P300

Mechanical Data
Mechanical Life (Typical)
Maximum # of Aux. Contacts

10,000
2

10,000
2

Construction
Mechanisms
Handles

Zinc plated steel


Steel, painted

Environmental Data
Ambient Temperature
Altitude
Relative Humidity

Open
Enclosed
Storage
2000m
90% @ 20C
50% @ 40C

20C+55C (4F+131F)
20C+40C (4F+104F)
40C+65C (40F+149F)

Refer to circuit breaker specifications for other limitations.

2-26

10,000
2

Bulletin 1494

Disconnect Switches and Circuit Breakers


Approximate Dimensions

Bulletin 1494V
Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.

FLANGE DRILLING
Standard
9/16 (14.3)

1/2
(12.7)

Optional
1/4 R
(6.4)
1-9/16
1
(39.7)
(25.4)

1-27/32
(46.8)
Operator

Common Industrial
Flange Cut-Out

Door
Provides for
Wire Bending
Space
Disconnecting
Means

F
B

2-7/8
(73)

4-11/16
(119.1)

Vertical Center Line of Operating Handle Drilling

Circuit
Breaker
Auxiliary
When Used

CL

CL

Square Corners
or 1/4 (6.4) R. Max.
(2) 9/32 (7.1)
Dia. Holes

7/8 (22.2)

Mech..

1
(25.4)

1/2 (12.8 )
Vertical
of Operating
Handle

(2) 9/32 (7.1)


Dia. Holes

Flange Cut-Out
1494V 30200A

Operating
Handle
Mounting
Surface

9/16
(14.3)

Disconnect Means
Mounting Surface

Vertical Center
Line of Operating
Handle

3
(76.2)

Trailer Fuse Block

5
(127)

Enclosure
Flange

6-1/2
(165.1)

Center Line
Oper. Mech.
1/4
(6.35)
1/2
(12.7)

Square Corners
or 1/4 (6.35) R.
21/64 (8.3) Dia.
2-Holes

Flange Cut-Out
1494V 400600A

Disconnect Switches
NEMA Size
(A)
30
60
100
200
400
600

B
A
6-19/64
(160)
6-19/64
(160)
6-19/64
(160)
8-5/64
(205.2)
15-23/32
(399.2)
15-23/32
(399.2)

Max
202
(7-31/32)
215
(8-15/32)
231.8
(9-1/8)
384.5
(15-9/64)
479.2
(18-7/32)
446.8
(17-19/32)

C
Min
171
(6-3/4)
171
(6-3/4)
171
(6-3/4)
197
(7-3/4)
193.7
(7-5/8)
193.7
(7-5/8)

Max
549
(21-5/8)
549
(21-5/8)
599
(28-5/8)
549
(21-5/8)
549
(21-5/8)
549
(21-5/8)

D
69.9
(2-3/4)
65.1
(2-9/16)
90.9
(3-37/64)
166.3
(6-35/64)
203.2
(8)
304.8
(12)

E
192
(7-9/16)
192
(7-9/16)
192
(7-9/16)
223
(8-25/32)
300.8
(11-27/32)
300.8
(11-27/32)

F
98.5
(3-7/8)
98.5
(3-7/8)
98.5
(3-7/8)
118
(4-21/32)
223.3
(8-51/64)
223.3
(8-51/64)

Circuit Breakers
C
Frame
150A
EHD, FD, FDB, FDC, HFD, HMCP
250A
JD, JDB, JDC, HJD, HMCP
400A
KD, KDB, KDC, HKD, HMCP

A
152.4
(6)
285.8
(11-1/4)
228.9
(11-3/8)

Min
171.5
(6-3/4)
200.0
(7-7/8)
200.0
(7-7/8)

Max
584.2
(23)
573.1
(22-9/16)
573.1
(22-9/16)

D
152.4
(6)
254
(10)
304.8
(12)

E
138.1
(5-7/16)
145.2
(5-23/32)
181.0
(7-1/8)

F
127
(5)
246.8
(9-23/32)
245.3
(9-21/32)

Approximate dimensions are for reference only.


This approximate dimension will vary by fuse class and size.
Approximate dimension with Class J fuses.

2-27

Bulletin 1494

Fixed-Depth Flange Mounted Operating Mechanisms


Approximate Dimensions, Continued
2

Bulletin 1494F, 1494M


Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
NEMA
Size
(A)

30
60

D
MIN.

100
200

F
K
Disconnect Switch

30
L

60

100
200

Door Catch

30

Flange Cut-Out

60
100
200
Circuit
Breaker
Auxiliary
When Used

Without Door Hardware


30.2
36.5
215.9
11.9
182.6
54
52.4
(1-3/16)
(1-7/16)
(8-1/2)
(15/32)
(7-3/16)
(2-1/8)
(2-1/16)
30.2
36.5
215.9
11.9
182.6
54
82.6
(1-3/16)
(1-7/16)
(8-1/2)
(15/32)
(7-3/16)
(2-1/8)
(3-1/4)
30.2
36.5
215.9
11.9
182.6
54
206.8
(1-3/16)
(1-7/16)
(8-1/2)
(15/32)
(7-3/16)
(2-1/8)
(8-9/64)
31.8
42.9
282.6
20.6
241.3
57.9
264.3
(1-1/4)
(1-11/16)
(11-1/8)
(13/16)
(9-1/2)
(2-9/32) (10-13/32)
Small and Intermediate Enclosures with Door Hardware
30.2
36.5
215.9
11.9
182.6
54.8
57.2
(1-3/16)
(1-7/16)
(8-1/2)
(15/32)
(7-3/16)
(2-5/32)
(2-1/4)
30.2
36.5
215.9
11.9
182.6
54.8
82.6
(1-3/16)
(1-7/16)
(8-1/2)
(15/32)
(7-3/16)
(2-5/32)
(3-1/4)
30.2
36.5
215.9
11.9
182.6
54.8
206.8
(1-3/16)
(1-7/16)
(8-1/2)
(15/32)
(7-3/16)
(2-5/32)
(8-9/64)
31.8
42.9
282.6
20.6
241.3
58.7
264.3
(1-1/4)
(1-11/16)
(11-1/8)
(13/16)
(9-1/2)
(2-5/16) (10-13/32)
Large Enclosures with Door Hardware
30.2
36.5
215.9
11.9
182.6
57.2
69.9
(1-3/16)
(1-7/16)
(8-1/2)
(15/32)
(7-3/16)
(2-1/4)
(2-3/4)
30.2
36.5
215.9
11.9
182.6
57.2
82.6
(1-3/16)
(1-7/16)
(8-1/2)
(15/32)
(7-3/16)
(2-1/4)
(3-1/4)
30.2
36.5
215.9
11.9
182.6
57.2
206.8
(1-3/16)
(1-7/16)
(8-1/2)
(15/32)
(7-3/16)
(2-1/4)
(8-9/64)
31.8
42.9
282.6
20.6
241.3
59.5
264.3
(1-1/4)
(1-11/16)
(11-1/8)
(13/16)
(9-1/2)
(2-11/32) (10-13/32)

Vertical Center Line of Operating Handle Drilling

Common Industrial
Flange Cut-Out

Door
Provides for
Wire Bending
Space
Disconnecting
Means

F
B

Disconnect Switches
NEMA
Size
(A)

Operating
Handle
Mounting
Surface

30
60
100
Disconnect Means
Mounting Surface

Trailer Fuse Block


Enclosure
Flange

200

C
A
B
150.8
273.1
(5-15/16)
(10-3/4)
150.8
335
(5-15/16) (13-3/16)
200.4
425.5
(7-15/16)
(16-3/4)
266.7
528.6
(10-1/2) (20-13/16)

Min
161.9
(6-3/8)
161.9
(6-3/8)
215.9
(8-1/2)
228.6
(9)

Max

D
55.6
(2-3/16)
50.8
(2)
127
(5)
177.8
(7)

E
190.5
(7-1/2)
190.5
(7-1/2)
209.6
(8-1/4)
289
(11-3/8)

F
95.3
(3-3/4)
95.3
(3-3/4)
95.3
(3-3/4)
141.3
(5-9/16)

Bulletin 1494D
Circuit Breakers
Cutler-Hammer/
Westinghouse Frame
150A
EHD, FD, FDB, FDC, HFD, HMCP
250A
JD, JDB, JDC, HJD, HMCP
400A
KD, KDB, KDC, HKD, HMCP
600A
LA, HLA, LC, HLC, LD, HLD
800A
MA, HMA, MC, ND, HND, NDC
800A
NB TRI-PAK
1200A
NB, HNB, NC, HNC, ND, HND, NDC

C
A
198.4
(7-13/16)
292.1
(11-1/2)
292.1
(11-1/2)
288.9
(11-3/8)
406.4
(16)
558.8
(22)
406.4
(16)

Minimum wiring space for the maximum wire size.


Approximate dimensions are for reference only.
This approximate dimension will vary by fuse class and size.

2-28

Min
161.9
(6-3/8)
212.7
(8-3/8)
212.7
(8-3/8)
241.3
(9-1/2)
241.3
(9-1/2)
241.3
(9-1/2)
241.3
(9-1/2)

Max

D
152.4
(6)
203.2
(8)
304.8
(12)
203.2
(8)
254
(10)
254
(10)
304.8
(12)

E
142.9
(5-5/8)
147.6
(5-13/16)
174.6
(6-7/8)
304.8
(12)
312.7
(12-5/16)
312.7
(12-5/16)
312.7
(12-5/16)

F
163.5
(6-7/16)
239.7
(9-7/16)
239.7
(9-7/16)
267.5
(10-17/32)
183.4
(15-3/32)
535.8
(21-3/32)
183.4
(25-3/32)

Bulletin 1494

Enclosed Disconnects
Approximate Dimensions, Continued

Bulletin 1494F
Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
F
J Mounting Hole
C

E
H

Disc. Size
(A)

DIM Ref.

30

A11

60 & 100

A12

200

A13

400

A14

228.6
(9)
330.2
(13)
533.4
(21)
685.8
(27)

228.6
(9)
228.6
(9)
266.7
(10-1/2)
355.6
(14)

28.2
(1-7/64)
28.2
(1-7/64)
28.2
(1-7/64)
28.2
(1-7/64)

254
(10)
355.6
(14)
558
(22)
685.8
(27)

82.5
(3-1/4)
82.5
(3-1/4)
101.6
(4)
152.4
(6)

165.1
(6-1/2)
165.1
(6-1/2)
203.2
(8)
228.6
(9)

63.5
(2-1/2)
63.5
(2-1/2)
63.5
(2-1/2)
87.3
(3-7/16)

102.8
(4-3/64)
102.8
(4-3/64)
124.6
(4-29/32)
186.5
(7-11/32)

9/32
(7.1)
9/32
(7.1)
9/32
(7.1)
8.7
(11/32)

Wire Size
Ampere Rating (A)

Line and Load Terminals

Ground Terminal

30
60
100
200
400

#14#6 AWG Wire


#14#4 AWG Wire
#8#1/0 AWG Wire
#6#4/0 AWG Wire
(2) #1/0 AWG - 250 kcmil

(2) #10#4 AWG Wire


(2) #10#4 AWG Wire
(2) #10#4 AWG Wire
(2) #6#4/0 AWG Wire
(2) #6#4/0 AWG Wire

2-29

Bulletin 1491

Fuse Blocks
2

Bulletin 1491
30A Fuse Blocks
With Spring-Type Fuse Clips
and Self-Lifting Wiring Terminal Clamps

30A Fuse Blocks


With Spring-Type Fuse Clips
Class R Rejection Feature
and Self-Lifting Wiring Terminal Clamps

60A Fuse Blocks


With Spring-Type Fuse Clips
and Tang-Type Connections
on the Wiring Terminals

100A Fuse Blocks


With Wedge-Type Fuse Clamps
and Tang-Type Connections
on the Wiring Terminals

Fuse Blocks
Available from
30A600A
Can be used with
Class H, J and R fuses

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31

Description

Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-33

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-32

Description
These Bulletin 1491 Fuse Blocks have been designed for general purpose
applications. The bases of these blocks, either phenolic or porcelain, are rugged in
construction and provide ease in mounting and wiring.

Conformity to Standards:

Approvals:

NEMA 512

CSA Certified (File No. LR 1234)


UL Listed (File No. E 34648)

2-30

Page

Bulletin 1491

Fuse Blocks
Product Selection
Fuse Blocks
Fuse
Size
(A)

Maximum
Voltage (V)

No. of
Poles

Class CC
Cat. No.

Class H
Cat. No.

Class J
Cat. No.

Class R
Cat. No.

Class C
(HRC Form II)
Cat. No.

1491-R162

1491-N121
1491-N122
1491-N125
1491-N161

1491-N126

1491-N126

1491-R125

1491-R126

1491-N226

1491-R226

600

1491-N266

1491-N266

1491-R266

1491-E126

250600

1
2
3

1491-N321

1491-N333

1491-R333

1491-E333

1491-R433

1491-R523
1491-R621

1491-E433

1491-E521

1
2
3
1
2
3

250

250
030
600

1491-E126

3160

61100

101200

250600

201400

250600

401600

250600

1
2
3
1
2
3
1
2
3

1491-N421

1491-N433
1491-N521

1491-N621

1491-N321

1491-N333
1491-N421

1491-N433
1491-N521

1491-N621

These fuse blocks have porcelain bases.


For two pole applications use two of Cat. No. 1491-N321.
For two pole applications use two of Cat. No. 1491-N421.
For two pole applications use two of Cat. No. 1491-N521.
For three pole applications use three of Cat. No. 1491-N521.
For two pole applications use two of Cat. No. 1491-N621.
For three pole applications use three of Cat. No. 1491-N621.
For two pole applications use two of Cat. No. 1491-R621.
For three pole applications use three of Cat. No. 1491-R621.

Specifications Page 2-32


Approximate Dimensions Page 2-33

Prices Consult Sales Office or price list

2-31

Bulletin 1491

Fuse Blocks
Specifications
Fuse Blocks
Electrical
UL Fuse Type
CSA Fuse Type
Maximum Fuse Cartridge Size
Maximum Voltage
AC
DC
Thermal Current Rating
Maximum Short Circuit Prospective Fault
Current
Mechanical
Degree of Protection
Terminal Capacity

mm2
AWG

Construction
Fuse Clips
Terminals
Fuse Block Base
Environmental
Ambient Temperature
Altitude (per IEC 947-5)
Relative Humidity (per IEC 947-3)

Product Selection Page 2-31

2-32

Class C
HRCI-C
30A600A
600V
250V

Class CC
HRCI-Misc.
30A
600V
250V

Class H
HRCI-H
30A600A
600V
250V

Class J
HRCI-J
30A600A
600V
250V

Class R
HRCI-R
30A600A
600V
250V

30A600A

30A

30A600A

30A600A

30A600A

100 kA

200 kA

10 kA

100 kA

200 kA

IP00
10

IP00
6

IP00
10

IP00
10

IP00
10

#8 (500 MCM)

#10

#8 (500 MCM)

#8 (500 MCM)

#8 (500 MCM)

Tin plated copper alloy


Tin plated copper alloy
Phenolic or Porcelain
Open
20C+55C (4F+131F)
Enclosed 20C+40C (4F+104F)
Storage 40C+65C (40F+149F)
2000m
90% at 20C and 50% at 40C

Bulletin 1491

Fuse Blocks
Approximate Dimensions
Fuse Size 130A
Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
19.05
(.75)

41.27
(1-5/8)

7.92
(.312)

42.86
(1-11/16)

7.1 Dia.
(9/32)
2 Holes
4.37 Dia.
(.172)
Rejection
Feature

(4) Terminals Combination Of:


Double Quick-Connect
(.250 x .032) 20 A Max.,
And Pressure Plate Screw
(10-32 Sems).
(Ref.) Wire: #10 AWG Max. Cu Only

41.15
(1.62)

79.38
(3-1/8)
157.16
61.91
(6-3/16)
(2-7/16)

Drill & Tap


2 Holes
For No.
10-32
Screws

76.20
(3.00)

15.88
(5/8)

32.51
(1.28)

130A, Single Pole, 600V


Cat. No. 1491-N161
Shipping Weight 0.45kg (1 lb)

Cat. No. 1491-R162


31.80
(1-1/4)

38.10
(1-1/2)
76.20
(3)
Drill & Tap
2 Holes
For No.
10-32
Screws
53.97
(2-1/8)

34.92
(1-3/8)

119.06
(4-11/16)

130A, 2-Pole, 250V


Cat. No. 1491-N122
Shipping Weight 0.91kg (2 lb)

14.29
(9/16)

46.04
(1-13/16)

Drill & Tap 4 Holes


For No. 10-32 Screws
Drill and Tap For
#10-32 Screws

119.06
(4-11/16)

46.04
(1-13/16)

14.29
(9/16)

1
Rejection Members

14.29
(9/16)

14.29
(9/16)

14.29
(9/16)

130A, 250600V
Cat. No. 1491-R125 (250V)
Cat. No. 1491-R126 (600V)
Shipping Weight 0.45kg (1 lb)

130A, 3-Pole, 250600V


Cat. No. 1491-N125 (250V)
Cat. No. 1491-N126 (600V)
Shipping Weight 0.45kg (1 lb)

Voltage
(V)
250
600

Class H
A

Class J
B

54.0 (2-1/8)
76.2 (3)

60.3 (2-3/8) 146.1 (5-3/4) 60.3 (2-3/8)

76.2 (3)

Fuse Size
(A)

Maximum
Volts (V)

Cat. No.

130

250
600

1491-R125
1491-R126

A
0.020

B
Ref.

74.68 (2.94) 53.97 (2-1/8)


145.29 (5.72) 60.33 (2-3/8)

Alternate mounting holes.


Dimension A must be held to insure fuse block rejection function.
Note: When fuse blocks are installed in a vertical plane, the block with the rejection numbers must be on the bottom.

2-33

Bulletin 1491

Fuse Blocks
Approximate Dimensions, Continued
Fuse Size 3160A
Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
141.29
(5-9/16)

Drill & Tap 4 Holes


For No. 10-32 Screws

14.29
(9/16)

46.04
(1-13/16)

141.29
(5-9/16)
Drill and Tap For
#10-32 Screws

46.04
(1-13/16)

14.29
(9/16)

Rejection Members

14.29
(9/16)

14.29
(9/16)

3160A, 3-Pole, 250600V


Cat. No. 1491-N226 (250V)
Shipping Weight 0.45kg (1 lb)

3160A, 250600V
Cat. No. 1491-R226 (250V)
Shipping Weight 0.45kg (1 lb)

Cat. No. 1491-N266 (600V)


Shipping Weight 0.91kg (2 lb)
Class H

Cat. No. 1491-R266 (600V)


Shipping Weight 0.91kg (2 lb)
Class J

Voltage
(V)

250
600

60.3 (2-3/8)
68.3 (2-11/16)

95.3 (3-3/4)
158.8 (6-1/4)

68.3 (2-11/16)

79.4 (3-1/8)

Fuse Size
(A)

Maximum
Volts (V)

Cat. No.

A
0.020

B
Ref.

3160

250
600

1491-R226
1491-R266

94.49 (3.72)
157.99 (6.22)

60.33 (2-3/8)
68.26 (2-11/16)

Drill & Tap 6 Holes


For 1/4" -20 Screws
Drill & Tap 4 Holes
For 1/4" -20 Screws

53.97
(2-1/8)
123.82
(4-7/8)
53.97
(2-1/8)

53.97 69.85
(2-1/8) (2-3/4)

A
26.99
(1-1/16)

26.99
(1-1/16)

A
26.99
(1-1/16)

Single Pole Application


Use One of Cat. No. 1491-N321
Approximate Shipping Weight 0.91kg (2 lb)

26.99
(1-1/16)

2-Pole Application
Use Two of Cat. No. 1491-N321
Approximate Shipping Weight Approx. 2 times wt. of 1-Pole
Drill & Tap 10 Holes
For 1/4" -20 Screws

Drill & Tap 8 Holes


For 1/4" -20 Screws
53.97
(2-1/8)
53.97
(2-1/8)
177.80
(7)

53.97
(2-1/8)
231.77
(9-1/8)

53.97
(2-1/8)
53.97
(2-1/8)
53.97
(2-1/8)
53.97
(2-1/8)
A

B
26.99
(1-1/16)

26.99
(1-1/16)

B
26.99
(1-1/16)

26.99
(1-1/16)

3-Pole Application
Use Three of Cat. No. 1491-N321
Approximate Shipping Weight Approx. 3 times wt. of 1-Pole

4-Pole Application
Use Four of Cat. No. 1491-N321
Approximate Shipping Weight Approx. 3 times wt. of 1-Pole

Class H

Class J

Voltage (V)

250
600

82.6 (3-1/4)
85.7 (3-3/8)

174.6 (6-7/8)
225.4 (8-7/8)

82.6 (3-1/4)

142.9 (5-5/8)

Alternate Mounting Holes.


Dimension A must be held to insure fuse block rejection function.
Notes:
1. When fuse blocks are installed in a vertical plane, the block with the rejection numbers must be on the bottom.
2. When using Cat. No. 1491-N321, install fiber washers between fuse blocks and mounting plates. Discard extra screws, washers and clamps on
multiple pole applications.

2-34

Bulletin 1491

Fuse Blocks
Approximate Dimensions, Continued
Fuse Size 61100A
Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
Drill & Tap 4 Holes
For 1/4" -20 Screws

171.45
(6-3/4)
50.80
(2)

B
28.57
(1-1/8)

28.57
(1-1/8)

3-Pole
Cat. No. 1491-N333
Approximate Shipping Weight 1.36kg (3 lb)

Class H

Class J

Voltage (V)

250
600

74.6 (2-15/16)
79.4 (3-1/8)

149.2 (5-7/8)
200.0 (7-7/8)

76.2 (3)

117.5 (4-5/8)

171.45
(6-3/4)
50.80
(2)
28.57
(1-1/8)

Drill and Tap For


1/4-20 Screws

28.57
(1-1/8)
Rejection Members

10.32
(13/32 Max.)

61100A, 250600V
Cat. No. 1491-R333
Shipping Weight 1.36kg (3 lb)

Fuse Size (A)

Maximum Volts (V)

Cat. No.

61100

250
600

1491-R333

A
0.020

B
Ref.

149.35 (5.88)
200.15 (7.88)

74.61 (2-15/16)
79.38 (3-1/8)

Dimension A must be held to insure fuse block rejection function.


Notes:
1. When fuse blocks are installed in a vertical plane, the block with the rejection numbers must be on the bottom.
2. Fuse blocks with wedge type clamps (61A and above) can be oriented to mount all fuses either to the left or to the right of fuse clamp centers.

2-35

Bulletin 1491

Fuse Blocks
Approximate Dimensions, Continued
Fuse Size 101200A
Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
222.25
(8-3/4)
69.85
(2-3/4)
34.92
(1-3/8)

Drill and Tap For


5/16-18 Screws

Fuse Size
(A)
34.92
(1-3/8)

101200
Rejection Members

Maximum
Volts (V)

Cat. No.

250

1491-R433

600

A
0.020

B
Ref.

184.15 (7.25)

106.36 (4-3/16)

247.60 (9.75)

109.54 (4-5/16)

15.08 max.
(19/32 Max.)

101200A, 250600V
Cat. No. 1491-R433
Shipping Weight 3.2kg (7 lb)

9.52
(3/8)

Drill For 5/16" -18 Screw

9.52
(3/8)

Drill For 5/16" -18 Screw

82.55 101.60
(3-1/4) (4)
28.57
(1-1/8)

82.55
(3-1/4)
209.6
(8-1/4)

9.52
(3/8)

B
50.80
(2)

82.55
(3-1/4)

50.80
(2)
28.57
(1-1/8)

Single Pole
Cat. No. 1491-N521
Shipping Weight 3.2kg (7lb)

9.52
(3/8)

B
50.80
(2)

50.80
(2)

2-Pole Application
Use Two of Cat. No. 1491-N521
Shipping Weight 6kg (13 lb)
9.52
(3/8)

Drill For 5/16" -18 Screw

9.52
(3/8)

Drill For 5/16" -18 Screw

82.55
(3-1/4)

82.55
(3-1/4)

82.55
(3-1/4)

317.50
(12-1/2)

425.45
(16-3/4)

82.55
(3-1/4)

82.55
(3-1/4)

82.55
(3-1/4)
28.57
(1-1/8)

28.57
(1-1/8)

9.52
(3/8)

B
50.80
(2)

82.55
(3-1/4)

50.80
(2)

3-Pole Application
Use Three of Cat. No. 1491-N521
Shipping Weight 8.6kg (19 lb)

A
120.7 (4-3/4)
125.8 (4-61/64)

Class J
B
228.6 (9)
304.80 (12)

117.5 (4-5/8)

Dimension A must be held to insure fuse block rejection function.


Note: When fuse blocks are installed in a vertical plane, the block with the rejection numbers must be on the bottom.

2-36

50.80
(2)

4-Pole Application
Use Four of Cat. No. 1491-N521
Shipping Weight 11.4kg (25 lb)

Class H or R
Voltage (V)
250
600

9.52
(3/8)

B
50.80
(2)

190.5 (7-1/2)

Bulletin 1491

Fuse Blocks
Approximate Dimensions, Continued
Fuse Size 201400A
Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
107.90
(4-1/4)
9.52
(3/8)

82.55
(3-1/4)

25.40
(1)

107.90
(4-1/4)
82.55
(3-1/4)

25.40
(1)

82.55
(3-1/4)

9.52
(3/8)
50.80
(2)

Drill and Tap


For 5/16-18
Screws

50.80
(2)

Rejection Members

6.35 max.
(1/4 Max.)
28.57
(1-1/8)

201400A, 250600V
Cat. No. 1491-R523
Shipping Weight 8.6kg (19 lb)

Fuse Size (A)


201400

Maximum
Volts (V)

A
0.020

Cat. No.

250

1491-R523

600

B
Ref.

228.60 (9.00)

120.70 (4-3/4)

304.80 (12.00)

125.81 (4-61/64)

Fuse Size 401600A

44.45
(1-3/4)

44.45
(1-3/4)

128.59
(5-1/16)

88.90
(3-1/2)

88.90
(3-1/2)

107.95
(4-1/4)

Single Pole
600A Terminations Only
Cat. No. 1491-N621
Shipping Weight 2.7kg (6 lb)

Class H or R

Class J

Voltage (V)

250

206.38 (8-1/8)

117.47 (4-5/8)

600

282.57 (11-1/8)

193.68 (7-5/8)

127.00 (6)

63.50 (2-1/2)

Dimension A must be held to insure fuse block rejection function.


Notes:
1. When fuse blocks are installed in a vertical plane, the block with the rejection numbers must be on the bottom.
2. Fuse blocks with wedge type clamps (61A and above) can be oriented to mount all fuses either to the left or to the right of fuse clamp centers.

2-37

Bulletin 1491

Fuse Blocks
Approximate Dimensions, Continued
Fuse Size 401600A, Continued
Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
127.00
(5)

88.90
(3-1/2)
44.45
(1-3/4)

88.90
(3-1/2)

401-600 Amp 206.25


(8-1/8)
250 Volts

117.35 401-600 Amp


250 Volts
(4-5/8)

44.45
(1-3/4)
Drill For 5/16 -18 Screw

401-600 Amp 282.45


600 Volts (11-1/8)

193.55 401-600 Amp


(7-5/8)
600 Volts

88.90
(3-1/2)

128.59
(5-1/16)

107.95
(4-1/4)

88.90
(3-1/2)
44.45
(1-3/4)

44.45
(1-3/4)

107.95
(4-1/4)

2-Pole
400A Terminations Only
Cat. No. 1491-N621 (Amt. 2)
Shipping Weight 5kg (11 lb)

127.00
(5)

127.00
(5)

88.90
(3-1/2)

88.90
(3-1/2)

44.45
(1-3/4)

44.45
(1-3/4)
117.35 401-600 Amp
250 Volts
(4-5/8)

206.38 401-600 Amp


250 Volts
(8-1/8)
282.57 401-600 Amp
600 Volts
(11-1/8)

193.55 401-600 Amp


600 Volts
(7-5/8)

Drill For 5/16 -18 Screw

88.90
(3-1/2)

88.90
(3-1/2)

44.45
(1-3/4)

128.59
(5-1/16)

88.90
(3-1/2)

44.45
(1-3/4)

107.95
(4-1/4)

44.45
(1-3/4)

107.95
(4-1/4)

44.45
(1-3/4)

88.90
(3-1/2)

107.95
(4-1/4)

3-Pole
400A Terminations Only
Cat. No. 1491-N621 (Amt. 3)
Shipping Weight 7.3kg (16 lb)

127.00
(5)
88.90
(3-1/2)

44.45
(1-3/4)

44.45
(1-3/4)

44.45
(1-3/4)

193.68 401-600 Amp


(7-5/8) 600 Volts

Drill For 5/16 -18 Screw


88.90
(3-1/2)
44.45
(1-3/4)

88.90
(3-1/2)
44.45
(1-3/4)

107.95
(4-1/4)

88.90
(3-1/2)
44.45
(1-3/4)

107.95
(4-1/4)

4-Pole
400A Terminations Only
Cat. No. 1491-N621 (Amt. 4)
Shipping Weight 9.5kg (21 lb)

2-38

88.90
(3-1/2)

117.47 401-600 Amp


(4-5/8) 250 Volts

206.38 401-600 Amp


(8-1/8)
250 Volts
282.57 401-600 Amp
(11-1/8) 600 Volts

107.95
(4-1/4)

88.90
(3-1/2)

88.90
(3-1/2)

44.45
(1-3/4)

128.59
(5-1/16)

127.00
(5)

127.00
(5)

88.90
(3-1/2)
44.45
(1-3/4)

107.95
(4-1/4)

You might also like