You are on page 1of 8

SUMMARY OF CHANGES

Addenda to the 2007 Edition of the Code are issued in the form of replacement pages. Revisions, additions, or
deletions are incorporated directly into the affected pages. It is advisable, however, that all replaced pages be
retained for reference.
Replace or insert the pages listed. Changes given below are identified on the pages by a margin note, A09,
placed next to the affected area. Revisions to the 2007 Edition are indicated by 07 and revisions in the 2008
Addenda are indicated by A08. For the listing below, the Page references the affected area. A margin note, A09,
placed next to the heading indicates Location. Revisions are listed under Change.
The Record Numbers listed below are explained in more detail in List of Changes in Record Number Order
following the Summary of Changes.

--``,``,,,``,,`,`,`,```,``,,`,`,-`-`,,`,,`,`,,`---

Page

Location

Change (Record Number)

xxv, xxvi

Foreword

Revised (06-343)

xxixxl

Roster

Updated to reflect 2009 Addenda

13

U-1

(1) Subparagraph (b) revised (08-1186)


(2) In subpara. (c)(2)(h), 3.2 corrected to 3-2 by errata
(08-1334)
(3) Subparagraph (k) deleted (08-90)

U-2(a)(5)

Added (08-90)

Table U-3

Note (3) revised (08-432)

UG-4(a)

Reference to Part UIG added to first sentence (08-1186)

11, 12

UG-11

(1) References to ANSI deleted from subpara. (a)(1)


(07-818)
(2) References to ANSI deleted from footnotes 5 and 7
(07-818)
(3) References to ANSI deleted from subparas. (c)(1) and
(c)(2) (07-818)

13

UG-14(b)

Revised (07-1493)

1416.1

UG-16(b)(2)

Revised (07-1220)

UG-20(a)

Last sentence added (02-4113)

UG-21

Last sentence added (02-4113)

19

UG-27(a)

First sentence revised (07-600)

30

UG-33(b)

Repeated definition of Ds deleted by errata (08-11)

33

UG-34(a)

In footnote 20, U-2(c) corrected to U-2(g) by errata


(08-743)

4344.1

UG-37(h)

Added (05-1552)

UG-37(i)

Redesignated from subpara. (h) (05-1552)

UG-43(d)

Revised (07-473)

UG-43(e)

References to ANSI deleted (07-818)

54

UG-45(b)(4)

References to ANSI deleted from footnote 26 (07-818)

70

UG-90(b)(16)

Reference to UG-101 added (04-1666)

5153

(c)

Page

Location

Change (Record Number)

7576.1

UG-101(a)

(1) Subparagraph (1) revised (04-1666)


(2) Subparagraph (1)(a) added (04-1666)
(3) In subparas. (4)(b) through (4)(d), Proof Test Reports
set in initial capital letters (04-1666)

UG-101(b)

First sentence of the second paragraph revised (04-1666)

81

UG-115(b)

Revised (08-804)

84

UG-117(f)

Last sentence of the sixth paragraph revised (08-432)

8698.2

UG-120(a)(4)

Revised (07-1755)

UG-125(a)

Reference to UG-137 revised to UG-138 (01-059)

UG-125(d)

Revised (07-262)

UG-127(a)

(1) Footnote 46 revised (01-059)


(2) Footnote 47 corrected by errata (08-1334)
(3) Subparagraph (2) revised in its entirety; footnote 51
revised (01-059)
(4) Subparagraph (3)(b)(1) revised (01-059)

UG-127(b)

Revised in its entirety; footnotes 57 and 58 revised


(01-059)

UG-129

(1)
(2)
(3)
(4)
(5)

Fig. UG-129.2

Caption revised (01-059)

UG-130

Revised (01-059)

UG-131

(1) In subpara. (e)(2), SI units formula corrected by errata


(08-79)
(2) Revised in its entirety (01-059)

UG-132

Revised in its entirety; footnote 61 revised (01-059)

UG-134

(1) Subparagraph (e) revised (01-059)


(2) Subparagraph (f) added (01-059)
(3) Subparagraph (g) redesignated from (f) (01-059)

UG-135(b)(2)

Footnote 62 revised (01-059)

UG-136(a)(3)

Revised (05-421)

UG-136(a)(6)

Revised (05-421)

UG-136(c)(3)

(1) First paragraph revised (01-059)


(2) Subparagraph (d) revised (01-059)

UG-136(c)(4)(a)(1)

Revised (01-059)

102

UG-137(c)(3)

Revised (01-059)

104104.3

UG-138

Added (01-059)

106

UW-2(d)(3)

Designated added before agent by errata (08-1334)

109

UW-11(b)

Revised (07-1623)

118

Fig. UW-13.3

In Note (1), spelling of greater corrected by errata


(08-11)

99
100

120

Subparagraph
Subparagraph
Subparagraph
Subparagraph
Subparagraph
(01-059)

(c) revised (01-059)


(d) revised in its entirety (01-059)
(e)(1) revised (01-059)
(f) added (01-059)
(g) redesignated from subpara. (f)

UW-16(b)

Definition of r1 revised (07-1261)

UW-16(c)(1)

Reference to UG-37(b) corrected to Fig. UG-37 by errata


(08-79)
(d)

Page

Location

Change (Record Number)

125

Fig. UW-16.1

Illustration (bb) revised (08-574)

126, 126.1

UW-16(f)(3)

(1) Subparagraph (a) revised (07-643)


(2) Subparagraph (a)(5) revised (07-643)
(3) Subparagraph (b) revised (07-643)

UW-16(f)(4)

Revised (08-574)

Fig. UW-21

Revised (07-1003)

UW-21

Revised (07-1003)

139

UW-40(f)(5)(b)

Reference to sketch (f) corrected to sketch (e) by errata


(08-79)

140

UW-46

Reference to UW-15(d) corrected to UG-37(g) by errata


(08-11)

UW-51(a)(3)

Reference to T-285 corrected to T-274.2 by errata


(08-1334)

141, 142

UW-52(c)(2)

Revised (06-263)

159, 160

UCS-56(a)

Reference to P-No. 15E added in second paragraph


(06-780)

165, 168.1

Table UCS-56

Entry under Material and Note (1) revised (06-780)

169

Table UCS-57

Revised (06-780)

173

Fig. UCS-66

Note (4) corrected by errata for SA/EN 10028-2 (08-1334)

189

Table UNF-23.2

SB-956 added (08-384)

190, 191

Table UNF-23.3

(1) N06035 added (07-797)


(2) SF-467 and SF-467M added (05-529)

192

Table UNF-23.5

SB-653 added (05-435)

200

Table UHA-23

For SA-268, S43036 added (05-88)

202, 203

Table UHA-23

(1) SA-1010 added (04-311)


(2) SA/JIS G4303 added (06-1604)

204

Table UHA-32

Note (1) under P-No. 7 revised (05-88)

233

UHT-34

Reference to sketch (l) corrected to (j) by errata; reference


to sketch (n) corrected to (l) by errata (08-11)

252

Fig. ULW-18.1

Definitions of r1 min. and r3 min. revised (07-1261)

262

ULT-2

Temperatures in subparas. (a) and (c) revised (07-1499)

ULT-5(b)

Temperatures revised (07-1499)

ULT-5(f)

Spelling of of corrected by errata (08-1334)

ULT-17(d)

Reference to sketch (k) corrected to (i) by errata (08-743,


08-1334)

ULT-27

Temperatures in subparas. (a) and (b) revised (07-1499)

ULT-28(a)

Temperatures revised (07-1499)

ULT-29

Temperatures revised (07-1499)

264267

Table ULT-23

Data for temperature at 150F and 65C added (07-1499)

268

ULT-99(a)

Temperatures revised (07-1499)

269, 270

Table ULT-82

Revised (07-1499, 03-1733)

133134.1

263

(e)

Page

Location

Change (Record Number)

271

ULT-99(c)

Temperatures revised (07-1499)

ULT-100(c)

Temperatures revised (07-1499)

272

ULT-115(a)(2)

Temperatures revised (07-1499)

274

Fig. UHX-3

Definition of component 15 revised (06-1189)

280, 280.1

UHX-12.3

Definitions of Ap and Cp added (08-30)

Fig. UHX-12.2

Added (08-30)

284

UHX-12.4(b)

Revised (08-30)

285288.1

UHX-12.5.9

Revised (08-30)

UHX-12.5.11

Revised (08-30)

UHX-13.3

Revised (08-30, 06-1189)

Fig. UHX-13.1

General Note revised (06-1189)

UHX-13.5.6

First equation revised (07-127)

UHX-13.5.7(b)

Last sentence revised (08-30)

UHX-13.5.8

Revised (08-30)

Table UHX-13.1

(1) Note revised (08-30)


(2) Last equation under part (3) corrected by errata
(08-30, 08-1334)

Table UHX-13.2

Title corrected by errata (08-1334)

UHX-13.5.10

Revised (07-127, 08-30, 08-306)

UHX-13.5.11

Revised (07-127)

298

UHX-13.6.3

Definition for Ss,b,1 added (08-30)

299

UHX-13.6.4(e)

Last sentence revised (08-30)

UHX-13.7.3

Reference to Step 10 revised to Step 11 in first paragraph


and in subpara. (b) (07-127)

300

UHX-13.8.4(g)

First equation revised (07-127)

300.1, 300.2

UHX-14.3

Definitions for Ap and Cp added (08-30)

304

UHX-14.4(a)

Third sentence revised (08-30)

306, 307

UHX-14.5.8

Revised (08-30)

UHX-14.5.10

Revised (07-127)

UHX-16

Revised (06-1189)

UHX-17

Revised (06-1189)

Table UHX-17

Title revised (06-1189)

326.1326.32

Part UIG

Added (98-403)

327, 328

1-2

Revised (07-600)

1-3

Revised (07-600)

333, 334

1-6

Subparagraphs (d)(3) and (e) revised (08-806)

347

2-1(c)

Revised (08-806)

354

2-6

In the last sentence of the first paragraph, spelling of


value corrected by errata (08-1334)

291293

297

309, 310

(f)

Page

Location

Change (Record Number)

381

Mandatory Appendix
5

Title revised (06-1189)

5-1(a)

Revised (06-1189)

5-1(e)

Revised (06-1189)

382

Fig. 5-1

Revised (06-1189)

383

5-5(f)

Revised (06-1189)

401

10-13(b)(3)

Revised (04-1666)

402

10-15(d)

First sentence revised (04-1666)

441

13-17(f)(2)

Note added under first Semicylindrical sections


(08-999)

458

Fig. 17-2

Corrected by errata (08-79)

473

23-2(a)

Revised (08-384)

23-4(a)(4)

Reference to SB-956 revised (08-384)

Mandatory Appendix
26

Title revised (06-1189)

26-2

(1) Subparagraph (e) revised (06-1188)


(2) Subparagraph (f) added (06-1188)

Fig. 26-1

Title revised (06-1189)

26-4.1(h)

Added (06-1188)

500

26-14.1.1

First sentence revised (06-1189)

502

26-14.2.1

First sentence revised (06-1189)

503

26-14.2.2(q)

Equation corrected by errata (08-1334)

26-14.2.2(r)

Equations corrected by errata (08-1334)

26-14.3.1

First sentence revised (06-1189)

504

26-14.3.2(g)

Equation corrected by errata (08-79)

505

Table 26-15.2

Value in the third column, ninth row corrected by errata


(08-79)

515

30-2

Subparagraphs (c)(1) and (c)(2) revised (97-289)

525.4, 525.5

Mandatory Appendix
36

Added (98-403)

525.6, 525.7

Mandatory Appendix
37

Added (98-403)

525.8, 525.9

Mandatory Appendix
38

Added (98-403)

525.10, 525.11

Mandatory Appendix
39

Added (98-403)

525.12525.14

Mandatory Appendix
40

Added (98-403)

551552.1

L-1.6

Equations corrected by errata (08-1334)

L-2.1.2

Last sentence revised (07-1416)

483486

(g)

Page

Location

Change (Record Number)

574

Fig. L-7.7.1

Revised (07-1192)

L-7.7.5

Title added (07-1192)

L-7.7.5(b)(1)

Revised (07-1192)

L-7.7.6

Title added (07-1192)

L-7.7.7

Revised in its entirety (07-1192)

L-7.7.8

(1) First paragraph deleted (07-1192)


(2) Subparagraphs (c) and (d) revised (07-1192)

L-7.7.9(a)

First sentence revised (07-1192)

581

Fig. L-9-1

Reference to ANSI deleted (07-818)

582

L-9.2.2

Reference to ANSI deleted from footnote 5 (07-818)

585

L-9.5.1(a)

Reference to ANSI deleted (07-818)

590, 591

M-4

Revised (01-059)

M-5.2

Definition of valve failure controls revised (01-059)

M-7

(1) Title revised (01-059)


(2) Subparagraph (b) revised (01-059)

M-9

Revised (01-059)

595

M-12

Revised (01-059)

598

R-11

Added (06-780)

602

Nonmandatory
Appendix W

Text redesignated and guide for preparing supplemental


data reports for parts constructed of graphite added
(98-403)

604

Form U-1

Line 18 revised (04-1666)

605

Form U-1A

Proof test added to line 9 (04-1666)

605.1

Form U-1B

Added (98-403)

609

Form U-3

Line 4 revised (07-1755)

611

Table W-3

Applicability of Note 12 to U-3 added (07-1755)

617

Form UV-1

(1) Column headings under line 2 revised (01-059)


(2) Circled guide numbers added (01-059)

618

Form UD-1

Revised (01-059)

619

Table W-3.2

Revised (98-403, 01-059)

633, 634

Nonmandatory
Appendix DD

Item 2 revised (08-1187)

663.10

Nonmandatory
Appendix MM

Added (98-403)

575576.1

593

--``,``,,,``,,`,`,`,```,``,,`,`,-`-`,,`,,`,`,,`---

NOTE:
Volume 59 of the Interpretations to Section VIII, Division 1, of the ASME Boiler and Pressure Vessel Code
follows the last page of this Addenda.
(h)

LIST OF CHANGES IN RECORD NUMBER ORDER


Record Number

Change

97-289

Mandatory Appendix 30, 30-1 revised to state that the rules of U-2(g) shall apply when any of the geometric
limitations stated in 30-2(c)(1) and (c)(2) cannot be satisfied for a partially drilled hole.
New Part UIG added.
UG-125(a) Reference changed from UG-137 to UG-138.
UG-127 General revision.
UG-129 General revision.
UG-130 Code Symbol changed to Code Symbol Stamp.
UG-131 General revision.
UG-132 General revision.
UG-134(e) Tolerance format changed to agree with new UG-134(f).
UG-134(f) Pin device set pressure tolerance added.
UG-134(g) UG-134(f) renumbered.
UG-135(b)(2), footnote 62 The phrase various rupture disk devices changed to nonreclosing pressure
relief devices.
UG-136(a)(6) The term screwed changed to threaded.
UG-136(c)(3) Code Symbol changed to Code Symbol Stamp.
UG-136(c)(3)(d) Code Symbol changed to Code Symbol Stamp.
UG-136(c)(4)(a)(1) Code Symbol changed to Code Symbol Stamp.
UG-137(c)(3) Code Symbol changed to Code Symbol Stamp.
UG-138 Added.
Appendix M-4 Several references changed from safety devices/valves to the generic pressure relief
devices.
Appendix M-5.2, definition of valve failure controls The phrase of the purpose changed to for the
purpose.
Appendix M-7 General revision.
Appendix M-9 General revision.
Appendix M-12 General revision.
Form UD-1 General revision.
Form UV-1 General revision.
Appendix W, Table W-3.2 General revision.
UG-20(a) and UG-21 revised to include reference to U-2(a).
Table ULT-82 revised for SB-209-A95083 thickness values.
SA-1010 UNS S41003 Grades 40 and 50 added to Table UHA-23 and to Note (1) of Table UHA-32.
New requirement added in UG-101(a)(1) that production vessels or vessel parts that utilize the results of a
proof test shall also comply with all other applicable rules of this Division, along with the addition of considerations/guidelines to evaluate possible re-use of proof-tested construction based on previous editions of this
Division; Proof-Test Reports added to the 10-15(d) checklist, reference to Proof Test Reports and to
UG-101 added as appropriate, editorial revisions made to MDR Forms U-1 and U-1A to ensure proper documentation of proof tests.
SA-268 UNS S43036 material added to Tables UHA-23 and UHA-32 Note (1).
UG-136(a)(3) modified to clarify lifting lever requirements for water service over 140F.
SB-653 UNS R60702 added to Table UNF-23.5.
SF-467 and SF-467M N05500 added to Table UNF-23.3.
Requirements to the Code for split reinforcing pads for nozzles added by inserting a new subpara. (h) to
UG-37.
UW-52(c)(2) revised to clarify the acceptance criteria for spot radiography.
In the Foreword, the phrase and Guidelines for Acceptable Non-ASTM Editions inserted after the first
appearance of Guidelines of Acceptable ASTM Editions. The word ASTM deleted from all subsequent
occurrences of Acceptable ASTM Editions.
UCS-56 revised to change P-No. 5B Group 2 to P-No. 15E Group 1.
New R-11 added to Nonmandatory Appendix R describing preheat recommendations.
Mandatory Appendix 26 revised to limit the design temperature to a maximum of 800F and permit the use
of the operating temperature properties for the fatigue analysis.
(1) The phrase thick-walled expansion joints replaced by the phrase flanged and flued or flanged only
expansion joints.

98-403
01-059

--``,``,,,``,,`,`,`,```,``,,`,`,-`-`,,`,,`,`,,`---

02-4113
03-1733
04-311
04-1666

05-88
05-421
05-435
05-529
05-1552
06-263
06-343

06-780
06-1188
06-1189

(i)

06-1604
07-127

07-262
07-473
07-600

07-643

07-797
07-818
--``,``,,,``,,`,`,`,```,``,,`,`,-`-`,,`,,`,`,,`---

07-1003
07-1192
07-1220
07-1261
07-1416
07-1493
07-1499
07-1623
07-1755

08-11
08-30
08-79
08-90
08-306
08-384
08-432
08-574
08-743
08-804
08-806
08-999
08-1186
08-1187
08-1334

(2) The phrases bellows-type expansion joints, pressure vessel and heat exchanger expansion joints, and
thin-walled expansion joints replaced by bellows expansion joints.
(3) Where appropriate, the phrase expansion bellows replaced with expansion joint.
Table UHA-23 revised to add SA/JIS G4303.
The following formulas revised:
Ps formula in UHX-13.5.6
Shell membrane stress formula in UHX-13.5.10
Shell and channel membrane stress formula in UHX-13.5.11
Shell bending stress formula in UHX-13.5.11 and UHX-13.8.4
Shell and channel membrane stress formula in UHX-14.5.10
UG-125(d) revised by adding testing as part of the requirement for accessibility along with inspection,
replacement, and repair.
The thickness in the third sentence of UG-43(d) changed to minimum required thickness. The phrase metal
added to weld metal added per UW-42.
(1) UG-27(a) revised to permit the minimum wall thickness to be based on the formulas given in Mandatory
Appendix 1.
(2) Equations (1) and (2) revised for thick cylindrical shells in 1-2 of Mandatory Appendix 1.
(3) Equations (1) and (2) revised for thick spherical shells in 1-3 of Mandatory Appendix 1.
(4) Clauses provided that permit equations in Mandatory Appendices 1, 1-2, and 1-3 to be used in lieu of
existing minimum thickness rules of UG-27(c) and UG-27(d).
UW-16(f)(3)(a) revised to clarify that reinforcement calculations are not required for fittings covered by the
paragraph, if the vessel does not experience rapid fluctuations in pressure and meets the spacing limitations
of UG-36(c)(3)(c) and (d).
UW-16(f)(3)(b) revised to clarify that if reinforcement calculations are performed, material in the fitting
neck shall not be used for area of reinforcement.
Code Case 2484 incorporated for UNS N06035 to 800F (427C).
The word ANSI deleted from Part UG, Part UW, Part UCS, Part UHA, Part UCI, Part UCD, Mandatory
Appendix 2, and Nonmandatory Appendix L.
UW-21(b) revised to delete reference to Fig. 2-4, and new Fig. UW-21 added.
Example revised to include calculations at 0 deg and 90 deg to vessel longitudinal axis. Calculation of A2
corrected for plane 90 deg to vessel axis.
UG-16(b)(2) revised to define who is responsible to provide the protective shell, casing, or duct when not
provided by the Manufacturer, and cautionary note added about leakage into the compartment.
UW-16(b) and Fig. ULW-18 revised.
Required thickness in the concluding statement of example L-2.1.2 changed from 0.232 in. to 0.244. in.
UG-14(b) revised to permit wrought rod or bar other than rolled or forged.
ULT-2, 5, 27, 28, 29, 99, 100, 115, Table ULT-23, and Table ULT-82 revised to permit the use of materials
in Part ULT up to and including 150F (65C) rather than 100F (40C).
The introductory phrase of UW-11(b) revised to improve clarity.
UG-120(a)(4) revised to permit National Board Registration of UM-Stamped vessels and the contact information added for the National Board of Boiler and Pressure Vessel Inspectors.
A line in Form U-3 added for the National Board Number.
An X in Table W-3 added to show that Note (12) applies to Form U-3.
Errata correction. See Summary of Changes for details.
Part UHX revised for consistency with Section VIII, Division 2, 4.18.
Errata correction. See Summary of Changes for details.
U-1(k) deleted and moved to U-2(a)(5).
In UHX-13.5.10, Step 10, the stress limit 2Ss replaced by SPS,s.
New specification B-956 adopted as SB-956, and stress lines added for SB-956 C70600 and C71500.
UG-117(f) revised to clarify who must be involved in the third year review for UM Stamp issue.
The minimum fillet weld throat size changed to tc from 14 in. for Fig. UW-16.1 sketch (bb). Also, words
added in UW-16(f)(4) to describe the fillet weld size.
Errata correction. See Summary of Changes for details.
UG-115(b) revised to be consistent with U-4.
Mandatory Appendix 1, 1-6(d), 1-6(e), and Mandatory Appendix 2, 2-1(c) revised to allow using standard
flanges listed in Table U-3 without performing flange design calculations per Mandatory Appendix 2.
Clarification added to example shown in 13-17(f).
UG-1(b) and UG-4 revised.
Under item 2, U Code Symbol Stamp, numbers 4, 9, and 11 revised. A new number 9 added and numbers 9
through 12 changed to numbers 10 through 13. A new number 14 added.
Errata correction. See Summary of Changes for details.

(j)