I GENERAL PROVISIONS
1.1. These Instructions for design, installation and safe operation of explosion-proof fans (hereinafter called
Instructions) define the requirements aimed for ensuring the industrial safety, prevention of emergencies and cases of
industrial injuries in the process of explosion-proof fans and ventilation systems operation in chemical, petrochemical and
oil refining industries.
1.2. Instructions are developed in accordance with Federal law as of 21.07.97 No. 116-FZ On industrial safety of
hazardous industrial objects (Collection of Russian Federation legislation, 1997. No. 30. Article 3588), Provision on
Federal mining and industrial inspection of Russia, approved by Decision of Russian Federation Government as of
03.12.01 No. 841 (Collection of Russian Federation legislation, 2001. No. 50. Article 4742), General industrial safety
instructions for organizations which activities are concerned with industrial safety of hazardous industrial objects,
approved by Decision of Gosgortehnadzor () of Russia as of 18.10.02 No. 61-, registered by Ministry
of Justice of Russia on 28.11.02, reg. No. 3968 (Rossiyskaya gazeta, 05.12.02, No. 231), and intended for use in all
organizations irrespective of their legal forms and ownership patterns, which activities are concerned with industrial safety
and which are supervised by Gosgortehnadzor () of Russia.
1.3. Instructions are intended for using:
a) in the course of engineering design, construction, operation, expansion, restructuring, technical upgrading, putting in
prolonged storage and liquidation of hazardous industrial objects at the factories of oil and gas processing, chemical,
petrochemical industries and other factories concerned with processing and storing toxic substances as well as the
substances able to form vapor and gas-air fire and explosion dangerous mixtures;
b) in the process of executing works concerned with engineering design, manufacturing, testing, installation, tuning up,
repair, technical diagnostics and operation of explosion-proof fans;
c) during industrial safety appraisement of hazardous industrial objects.
inspection and diagnostics so as to evaluate in accordance with established procedure the possibility of their further
operation.
2.5. Fans designed for moving the explosive mixtures of particular categories and groups can be used for moving other
explosive mixtures, which belong to lower categories and groups.
(nipple) for draining of the condensate is provided equipped with tightly closing plug or other closing device.
3.11. The fans are equipped with earthing clip and the earthing symbol made in accordance with requirements of state
standards.
3.12. Runners are subject to dynamic balancing. Permissible remaining unbalance of the runners after the balancing
should not exceed values stipulated by state standards.
When manufacturing the fans with coated flow-through part the runners balancing is to be conducted prior to the
application of the coatings. If the polymer coatings with thickness more than 0.4 mm are used it is necessary to
additionally check the runners for unbalance after the application of the coatings.
3.13. For stiff fan shafts the critical rotation frequency is defined to exceed the rated value by not less than 30%.
3.14. So as to inspection and cleaning of the internal surface of the housing and runner the tightly closing hatch with
dimensions not smaller than 200x300 mm is provided for fans of No. 10 and above.
3.15. In order to prevent leakage of the moved explosive mixture it is necessary to install the plate made out of yellow
metal or the other nonsparking material (plastic, paronite, rubber etc.) corresponding to the operation conditions; it is
installed onto rear wall of the housing of the fan made of dissimilar materials from outside at the place of the shafts
passage. It is recommended to fix the plate with self-tapping screws made of nonsparking material.
3.16. In the middle pressure fans the cup-type seal is installed at the place of the shafts passage.
3.17. In the high pressure fans the non-contact labyrinth seal is installed; at that for exhaust of the gas the bypass
pipeline is mounted which goes from housing of the labyrinth seal to collector or additional grooves in the runners boss;
the blades for exhaust of the gas from the labyrinth seal are installed at the rear side of the runners back disk.
The labyrinth seal has a hole for installation of the heating temperature control device. The labyrinth seal is made of
nonsparking materials (yellow metal, bronze etc).
3.18. For intermediate shafts of the 3-rd construction design modification fans it is necessary to use only roll bearings
with service life of not less than 40 000 hours.
3.19. Bearings should be protected against ingress of the dust and the dirt. In order to prevent leakage of the greasing
the connection of lids with the bearing housing is made tight.
3.20. The bearing housings have the holes for installation of the bearing temperature control sensors.
3.21. If the fans are stored for more than one year since the shipping from organization-manufacturer the bearings are
inspected with the lids removed and checked for greasing presence which should fill / of the bearing unit volume.
3.22. The fastening construction design of the motors and bearing housings should exclude the possibility of their
displacement in any direction.
3.23. In the construction design of the fans the devices for drawing off the static electricity is provided
3.24. When fans are built with the use of polymer materials in order to draw off static electricity the electroconductive
fillers should be added into plastic, electroconductive coatings should be applied, all parts of the fans should be earthed
etc.
3.25. The 3-rd construction design modification fans have the running contact for drawing off the static electricity from
the runners shaft using two copper graphite brushes closely fitting to the shafts surface and earthed with flexible copper
wires.
3.26. The parts made of plastic are selected during development of the engineering design documentation.
Bulging, cracks, dimples, sponginess, warping, layering of the plastic parts are not permitted.
3.27. For welding of the parts and assemblies of the fans the weld joints are made in accordance with requirements of
the normative technical documentation for the fans as well as state standards.
3.28. When assembling the undercarriage of the runners their fastening should exclude rotating in reference to the
shaft and movement in axial direction.
3.29. Axial and radial clearances between the runner and inlet fitting for radial fans, between the runner and housing
for axial fans, should be not less than 0,01 of the runners diameter in all points of periphery of circle (appendix 2).
3.30. All threaded joints of the fans parts and assemblies should be protected against self-unfastening in the course of
operation.
3.31. Runners or outside surfaces of collectors or flanges of the fans, couplings and guard devices are painted in
signal colors in accordance with requirements of state standards.
3.32. The direction of rotation of the fans runner is indicated by arrow on the suction side of the fan housing.
If it is necessary to transport the fun non-assembled the arrows are applied on the fan housing and on the runner.
The method of the arrows application should guarantee their preservation.
3.33. Fans produced for operation in explosion hazard zones of Classes B-1, -1a, -1b, should be supplied complete
with vibration isolators of explosion-proof versions.
3.34. Supply of the fans complete with guiding devices is executed in accordance with technical documentation.
3.35. The fans are supplied complete with explosion-proof electric motors having required level of explosion protection
in accordance with requirements of electric installation code.
In case the fans are placed inside the premises with chemically active, damp or dusty atmosphere the motors should
be protected against the impact of this atmosphere.
3.36. When placing the order for engineering design and manufacturing of the fans the client executes the application
with the list of technical requirements.
Recommended list of technical requirements is given in appendix 3.
3.37. Fans are equipped with devices for slinging in accordance with requirements of technical documentation. These
devices as well as slinging schemes are given in technical documentation supplied with the fan including the case of
separate transportation of the runner. Completeness of set and contents of technical documentation should correspond to
the specified requirements.
3.38. On the fan housing the corrosion-proof plate is mounted which includes the identification:
trademark or the name of organization-manufacturer; type and identification number of the fan; production serial
number; weight;
power of electric motor, voltage and rotation frequency;
year of manufacture;
number of technical specifications or drawing.
3.39. Manufactured and tested fans (or their components) and their technical documentation are subject to
preservation and (or) packaging which ensures the product and documentation integrity during transportation and storage
in respective climatic regions.
repair.
6.6. The fans operating controls are equipped with the means preventing self-starting of the motors when the electric
power supply is restored after electric power cut-off.
6.7. Installation of the fans supplied by the manufacturer as non-assembled items is done only after their assembling
and checking their operational capability in operational mode.
Assembling and fixation of the fans to the foundation should guarantee required strength excluding their deformation
and displacement.
6.8. Prior to installation the following should be done:
inspection of the explosion-proof fan, motor and verification of the installation places and foundation against the
engineering design documentation;
checking the insulation resistance of the motor and tightness of the bolted connections (fixation of the motor and fan
housing to the framework or foundation, runner on the drives shaft, bearing housings etc).
checking the axial and radial clearances between the runner and collector (for radial fans) and between the runner and
manacle ring of the housing (for axial fans);
checking the quality of the rubber elastic elements of vibration isolators.
6.9. If found out that explosion-proof fans are damaged or supply is non-complete their commissioning is not permitted.
6.10. Unpacking and removing from storage of the fans which are to be installed in the conditions of running explosion
hazardous factories is done at specially allocated places outside the explosive zone.
6.11. Before input of the gas- vapor- air mixture to the fan built-in production process scheme, the alarm sensor of prior
to explosive concentrations is installed that sends the signal to control room and if necessary to the system of automatic
protection against emergencies (PAZ, - ).
6.12. Fresh air fans should be installed at locations which exclude entering the explosive vapors, gases, dust into
ventilation in all operating modes of the factory.
6.13. The interlocks are installed on the fans of local exhaust, which exclude starting and running respective
processing equipment if the fans are off.
6.14. Vibration isolators should be installed in such a way that the load for each vibration isolator is evenly distributed.
6.15. When installing explosion-proof fans in the conditions of running explosion hazardous factories it is necessary to
use the tools, accessories and fixtures, which exclude the possibility of spark formation.
6.16. Air ducts on the pressure side and on the suction side are connected to the fan via soft insert. The connection
must ensure tightness. Fans and air ducts should form closed electric circuit.
6.17. Connection of air ducts to the fan is done only after checking the easiness of the runner rotation, absence of
unbalance by making marks on the runner and inlet fitting with the chalk (when runner is rotated two or three times it
should not stop at the same place).
6.18. In order to prevent foreign objects from entering the fan at the suction part of air duct if necessary the pocket
(input of the moved medium from below) is provided or the barrier grills (meshes) are installed with the mesh size of not
more than 12x12 mm.
6.19. When fans are installed outside the premises it is necessary to arrange special covers for them. At that the
convenience of installation and maintenance during operation is to be ensured.
6.20. All rotating parts of the fans should have guards excluding possibility of injuries for personnel.
6.21. Earthing of the explosion-proof fans is executed in accordance with requirements of the electric installation code.
6.22. After installation the trial start and running testing of the fans should be conducted at the open air.
6.23. Prior to starting the fans it is necessary to check:
greasing presence in the motors bearings and assemblies of the runners shafts;
absence of the ice on the runner and icing on the flexible insert of the fans in winter season;
reliability of the earthing of fan housings, motors and if necessary draw off the static electricity from the drives shaft.
6.24. In the process of trial starts and running testing the quality of installation of the fans, motors and other parts and
components, temperature of the bearings heating, vibration and other parameters according to normative technical
documents should be checked.
6.25. Explosion-proof fans must be immediately switched off if there is excessive vibration, appearance of impacts,
unwanted noise, fire or smoke, increasing of the temperature of motor housing, bearing housings and other parts of the
fans in excess of permissible level.
6.26. The fans are commissioned after completion of preoperational testing with execution of the act of acceptance
and necessary operational documentation in accordance with requirements of normative technical documents.
6.27. It is not permitted to install fans as well as electric motors for them, which are not meeting the requirements of
explosion protection for the class of explosive zone in accordance with classification of explosive zones and explosive
mixtures, and also these Instructions.
Frequency and methods of control are specified in operation manual for the fans.
7.10. If there are prolonged pauses in operation of the fans the measures for corrosion prevention in the bearings are
taken.
7.11. Backup fans should be put into short-time operation in every 3-4 weeks.
7.12. In the process of operation it is necessary to visually monitor the condition of the couplings of the motor shaft and
runner shaft or pulley wheels and belts on the motor and runner shafts. The plain faces of the couplings should not touch
each other. Belts must have uniform pull-up that is checked in the course of technical inspections.
7.13. When fans are operated it is necessary to see after the vibration isolators so that they are not exposed to
corrosion and all fastening parts are tightened up.
7.14. In the process of fans operation the control is executed over closeness of brushes adjoining to the drives shaft
for drawing off static electricity from the runner.
Frequency and methods of control are specified in operation manual for the fans.
7.15. The fan should be immediately stopped in the following cases:
appearance of impacts, noises and vibration in the fan, motor or coupling;
exceeding permissible temperature of the fan and motor components;
cracks in the foundation;
leaks of gases or vapors from the fan or air duct.
7.16. In case of the fan stoppage due to runners unbalance priot to its staring it is necessary to check condition of the
shaft and the bearings.
7.17. For simultaneous switching off all fans functionally linked to the equipment or built-in production process
schemes as well as other fans installed in explosion-hazardous premises the device should be provided located outside
the building and in control room.
7.18. For the fans which are operated at explosion hazardous factories and not meeting the requirements of these
Instructions it is necessary to obtain findings report concerning the possibility of their further operation from specialized
(expert) organization.
8.8. In the process of major repair of the fans the design dimensions of the parts and components should not be
altered. Introduction of design changes without approval of the designer of the fans is not permitted.
8.9. The procedure of handing over the fans to major repair and taking them over after the repair is conducted in
accordance with maintenance and repair instruction for explosion-proof fans and manufacturers instructions.
8.10. Scope of major repair works is recorded in the logbook of repairs (current and major) and in the certificate of the
fan.
8.11. After major repair the fun is running-in for two hours and in the course of it the heating of the bearing housings,
vibration and tightness (with closed shutters or with connected air ducts) are checked.
8.12. For repair of the fans it is not permitted to use materials with spark safety, corrosion resistance and mechanical
strength lower than corresponding parameters of materials the fans made of.
8.13. Prior to disconnection of the fan from air ducts for repair if there is explosive mixture inside them it is necessary
to blow off the system with inert gas or air.
It is prohibited to execute repair works on ventilation system before it was cleared from explosive substances, fan was
fully stopped and measures preventing its accidental start were taken.
8.14. When executing inspection, disassembling and assembling of the fans functionally linked to the equipment or
built-in process schemes as well as other fans installed in explosion-hazardous premises it is necessary to use
corresponding tools and accessories.
8.15. When repairing the housing, labyrinth seal and fan shaft seals it is not allowed to install damaged seal gaskets
and have scratches on the shaft under the labyrinth. The labyrinth seal clearance is adjusted again.
8.16. Prior to commissioning the fans built-in production process scheme after repair or prolonged stop the flowthrough part of the fans should be blown off with inert gas.
8.17. Motors after repairs are passing the testing according to program of approval testing with taking into account the
requirements of state standards.
Results of approval testing are recorded in the logbook of testing.
8.18. When executing the repair of the fans at running explosion hazardous factories the welding and other works
involving open fire or spark formation are conducted in accordance with requirements of normative technical documents
on industrial and fire safety.
8.19. If in the course of repair the works, which involve movement of the parts and components with load lifting cranes
are executed the requirements concerning movement of the loads with load lifting mechanisms should be adhered to.
Appendix 1
Reference
1st version
2nd version
b
1st version
2nd version
2.5. Dust level (value of dispersed contents of the dust, %, total value of dust level, g/m ;
characteristic of the dust according to physical, mechanical properties, chemical characteristics
including tendency to form explosive spark making deposits in the fan and system)
__________________________________________
2.6. Category and group of explosion hazard of the medium
3. Parameters and characteristics of the newly developed production:
3.1. Parameters of use (proved by construction design, calculations, testing and researches for
analogues fans):
capacity, m /h
full pressure, Pa
rotation frequency, min
maximum full performance factor
generating capacity of the electric motor, kW
voltage, V _________ frequency, Hz ______________ current _____________
3.2. Parameters of reliability:
mean life before first major repair, h
specified lifetime, years
mean
time
between
failures, h
4. Domestic and foreign (if exist) analog fans working in these conditions (type, parameters,
material, shift-working arrangement, service life)
5. Characteristic of the environment:
temperature,
humidity, %
Dust level (contents and value of dust level, characteristic of the dust by components and
aggressivity, dust dispersiveness)
6. Other requirements:
6.1. Requirements to the painting of the fan _____________________________
6.2. Requirements to the structure of spare parts, accessories, materials
6.3. Requirements to preservation and packaging (depending on the conditions of
transportation and storage) ____________________________________
6.4.
Other
operational
requirements
___________________________________________
(design,
technological
etc.)
Requisites:
Client
postal
telegraphic
shipping
Job title and signature of the responsible
representative of the client
(Name, Surname)
Date ___ ____________ 20 __
Stamp of the client
Appendix 4
Recommended
Aggressive
High aggressivity medium
components,
which are part of Concent
Recommended
Recommended
Recommended
explosive
mixtures
1
Sulphuric
(vapor)
Chlorhydric
(vapor)
Nitric
(vapor)
Phosphoric
(vapor)
Fluohydric
(vapor)
Acetic
(vapor)
ration
mg/m
2
acid >2,5
materials and
coatings
3
1017133,
0628
1017133,
0628
1017133,
0628
1017133,
0628
0628
ration,
materials and
coatings
mg/m
4
5
0,3-2,5 1017133,
0628
1-5
1017133,
0628
10-20 1017132,
121810
50-100 1017133,
121810
1-5
0628,
1017133
1-5
1017133,
17132
acid
>5
acid
>20
acid
>100
acid
>5
acid
>5
1017133,
23283-3
Chlorine (humid
gas)
Bromine (humid
gas)
Hydrogen
sulphide (humid
gas)
Carbon
disulphide
>10
1017133,
0628
0628,
1017133
0628,
1017133
1017133,
121810
20-50 0628,
1017133
10-100 1017133,
121810
0628,
121810
10-100 121810
>50
>100
>100
5-10
ration,
mg/m
6
<0,3
<0,3
<10
<50
<10
<1
<5
<20
<10
<10
materials and
coatings
7
1017133,
121810
1017133,
121810
121810, 3
+ polymer coating
121810, 3
+ polymer coating
121810, 3
+ polymer coating
17132,
121810
121810, 3
+ polymer coating
1017133,
121810
121810, 3
+ polymer coating
3
Instructions for design, installation and safe operation of explosion-proof fans (PB 03-59003)( 03-590-03)
Decision of Gosgortehnadzor () of Russia as of 10.06.06.2003 No. 84
Gosgortehnadzor () of Russia
Common for all or several areas of supervision, chemical, petrochemical, oil refining and other air fire and explosion
dangerous and hazardous factories
Effective