You are on page 1of 2

Technical Data Sheet

RF_35/05.10/6.0

Dieses Dokument ist urheberrechtlich geschtzt This document is protected by copyright Rosenberger Hochfrequenztechnik GmbH & Co. KG

SLink
Cable

SL 1 5/8RK FRNC

SL 158U RK FRNC

This product used for mobile network and telecommunication equipment

Materials and dimension


Inner Conductor Material
Dielectric
Outer Conductor
Jacket
Ink markingmetric length

Helical Copper Tube


18.0 mm
Foamed PE
42.8 mm
Overlapping Copper Foil
43.5 mm
PE, Flame Retardant Non Corrosive(FRNC) 48.0 mm
Black, UV resistant, Halogen free
RosenbergerSLinkTM_SL 158U_RK_FRNC_50_ _ _ _ _(DD+MM
+SS+YY+NNNNN)_ _ _ _ _XXXXm

Documents
Fire Resistance

IEC 60332-1; IEC 60332-3C-24

Electrical Specifications
Impedance
Capacitance
Insulation Resistance
Insulation Voltage
Jacket Spark Test Voltage
Inner conductor DC-resistance
Outer conductor DC-resistance
Relative velocity of propagation
Operating Frequency Band
Stop Band
VSWR

50 2
75 pF/m
5000 M x km
15000V
10000 Vrms
1.50 /km
1.60 /km
89%
75MHz to 2700 MHz
1012 to 1052MHz & 2025 to 2110MHz
1.3 75 MHz to 150MHz
1.3 800MHz to 960MHz
1.3 1700MHz to 2025MHz
1.3 2110MHz to 2170MHz
1.3 2300MHz to 2700MHz

Rosenberger Hochfrequenztechnik GmbH & Co. KG, Germany


Tel.: +49 8684 18-0
Fax: +49 8684 18-499
www.rosenberger.de
email: info@rosenberger.de

Rosenberger Asia Pacific Electronic Co., Ltd., China


Tel.: +86 10 80481995
Fax: +86 10 80497052
www.rosenbergerap.com
email:info@rosenbergerap.com

Page
1/2

Technical Data Sheet


SLink
Cable

SL 1 5/8RK FRNC

SL 158U RK FRNC

Environmental Specifications

RF_35/05.10/6.0

Dieses Dokument ist urheberrechtlich geschtzt This document is protected by copyright Rosenberger Hochfrequenztechnik GmbH & Co. KG

Installation Temperature
Operating Temperature
Storage Temperature
RoHS

-40 C to +80 C
-55 to +85
-55 to +85
Compliant

General Specifications
Cable Type

Radiation Mode

Mechanical Specifications
Minimum Bend Radius,
Single Bend
Multiple Bend
Bending Moment
Minimum Distance to Wall
Recommended Hanger Spacing
Tensile Strength

510 mm
900 mm
16N.m
50 mm
0.8 m to 1.2m
3000 N

Standard Conditions
Attenuation Test Method
Attenuation Tolerance
Attenuation Ambient Temperature
Average power, ambient temperature
Average power, inner conductor temperature
Coupling Loss Test Method
Coupling Loss Tolerance

IEC 61196-4
5 %
20 C
40 C
100 C
IEC 61196-4
5 dB

Performance
Frequency [MHz]

75

100

150

700

800

900

1800

2000

2200

2400

2700

max.Attenuation(dB/100m)

0.63

0.84

0.94

1.95

2.16

2.37

3.70

4.22

4.73

5.15

6.49

Coupling loss2m dB(50%)

70

70

78

74

70

69

64

63

62

61

63

Coupling loss2m dB(95%)

79

81

90

77

73

72

67

66

65

65

66

While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.

Draft

Date

huanghuan

11/03/15

Check

Approved

Date

Rosenberger Hochfrequenztechnik GmbH & Co. KG, Germany


Tel.: +49 8684 18-0
Fax: +49 8684 18-499
www.rosenberger.de
email: info@rosenberger.de

Rev.

Engineering change number

Name

Date

-------

huanghuan

23/09/15

Rosenberger Asia Pacific Electronic Co., Ltd., China


Tel.: +86 10 80481995
Fax: +86 10 80497052
www.rosenbergerap.com
email:info@rosenbergerap.com

Page