TXL 50 Ohm Corrugated Cable
Innovative design, high quality materials and closely controlled processes enable us to offer TXL coaxial cables which meet the
most stringent requirements and deliver the maximum in system performance.
Materials Tooling
Standard Jacket – Black Polyethylene Strip Tool – TXL-ST-A4 (½” Cable)
Outer Conductor – Corrugated Copper Superflex Strip Tool – TXL-ST-S24
Dielectric – Polyethylene Foam Blades for TXL-ST-S24 – TXL-STBL-KIT
Inner Conductor – Copper Clad Aluminum Dielectric Removal – TXL-CC100 (up to ½”)
Blades for TXL-CC100 – TXL-16722
Temperature
– TXL-CXC-1 (up to ½”)
Storage – -70ºC to 80ºC
Cable Cutting Tool
Operating – -40ºC to 80ºC
TXL Corrugated Cable Specifications (FR Suffix indicates Flame Retardant Cable)
Type SFC (SuperFlex) AFC (Annular)
Size 1/4” 3/8” 1/2” 7/8” 1/2” 5/8” 7/8” 1-1/4” 1-5/8”
SFC- SFC- SFC- SFC- AFC- AFC- AFC- AFC- AFC-
150J 250J 450J 550J 450J 500J 550J 650J 750J
Part Number:
SFC- SFC- SFC- SFC- AFC- AFC- AFC- AFC- AFC-
150JFR 250JFR 450JFR 550JFR 450JFR 500JFR 550JFR 650JFR 750JFR
Physical Dimensions
Inner Conductor (Diameter – mm) 1.91 3.15 3.60 9.35 4.80 7.05 9.05 13.10 17.30
Outer Conductor (Diameter – mm) 6.40 9.50 12.20 24.90 13.80 19.80 24.90 35.80 46.50
Thickness 0.60 0.85 0.70 1.05 1.00 1.20 1.30 1.80 1.75
Jacket (mm)
Diameter 7.60 11.20 13.60 27.00 15.80 22.20 27.50 39.40 50.00
Weight (Kg/km) 80 135 210 430 250 420 530 1085 1470
Mechanical Characteristics
Single Bend 25 50 25 80 70 90 120 200 300
Bend Radius
x10 Bends 30 95 30 125 125 200 250 380 510
(Minimum - mm)
Mobile Appl. 200 300 200 400 350 450 500 --- ---
Max Pulling Strength (N) 680 800 800 1020 1130 3630 1470 5900 3630
Electrical Characteristics
DC Resistance Inner Conductor 9.80 3.48 2.69 2.70 1.48 0.49 1.05 0.72 0.83
(≤ Ω/km, @ 20ºC) Outer Conductor 6.50 2.85 3.28 1.19 1.90 1.37 1.18 0.62 0.52
Nominal Capacitance (pF/m) 79.4 75 82 74.2 75.8 76.1 75 75 76
Impedance (Ω) 50Ω ±1
Cut-off Frequency (GHz) 20.40 13.50 10.20 4.90 8.80 6.10 6.00 4.00 3.00
Peak Power Rating (kW) 6.4 15.6 15.6 90 40 62 91 205 315
DC Breakdown (v) 1600 2500 2500 6000 4000 5000 6000 9000 11000
Shielding Effectiveness (dB) >> 120
Insulation Resistance (MΩ / km) ≥ 5 x10³
Velocity Ratio (%) 84 88 84 88 88 89 89 89 88
0.01GHz – 3GHz ≤1.15 ---
0.01GHZ – 2GHz --- ≤1.15
VSWR 820MHz – 960 MHz
1.7GHz – 1.9GHz ≤1.10
2.1GHz – 2.2GHz
TXL 50 Ohm Corrugated Cable – Continued
Attenuation (20ºC, dB/100m)
10 MHz 1.83 1.06 1.04 0.40 0.67 0.48 0.37 0.25 0.20
100 MHz 5.89 3.42 3.41 1.30 2.17 1.55 1.19 0.83 0.67
150 MHz 7.25 4.22 4.21 1.61 2.67 1.92 1.47 1.03 0.83
200 MHz 8.41 4.90 4.91 1.87 3.10 2.24 1.72 1.20 0.98
300 MHz 10.40 6.06 6.09 2.32 3.83 2.78 2.13 1.50 1.22
450 MHz 12.80 7.51 7.59 2.88 4.75 3.46 2.65 1.87 1.53
800 MHz 17.40 10.20 10.40 3.94 6.46 4.75 3.63 2.59 2.13
900 MHz 18.40 10.90 11.20 4.22 6.87 5.07 3.88 2.77 2.29
1000 MHz 19.60 11.60 11.80 4.46 7.28 5.38 4.12 2.94 2.43
1500 MHz 24.30 14.40 14.90 5.60 9.09 6.78 5.18 3.73 3.11
1800 MHz 26.90 16.00 16.60 6.21 10.10 7.54 5.75 4.16 3.47
2000 MHz 28.50 17.00 17.60 6.59 10.70 8.02 6.11 4.43 3.71
2500 MHz 32.10 19.30 19.20 7.50 12.10 9.15 6.95 5.08 4.27
3000 MHz 35.60 21.40 22.40 8.35 13.40 10.20 7.76 5.68 ---
Average Power Rating (Ambient Temperature 40ºC, inner conductor temperature 80ºC), kW
10 MHz 3.97 7.23 10.10 21.50 11.30 16.70 24.60 38.60 54.30
100 MHz 1.23 2.24 3.08 6.62 3.49 5.14 7.56 11.70 16.40
200 MHz 0.865 1.56 2.14 4.61 2.44 3.57 5.26 8.12 11.30
300 MHz 0.701 1.26 1.72 3.72 1.97 2.87 4.24 6.52 9.01
450 MHz 0.567 1.02 1.38 2.99 1.59 2.31 3.41 5.22 7.18
800 MHz 0.419 0.748 1.01 2.19 1.17 1.68 2.48 3.78 5.15
1000 MHz 0.372 0.663 0.889 1.94 1.04 1.48 2.19 3.32 4.52
1500 MHz 0.299 0.53 0.705 1.54 0.833 1.18 1.74 2.62 3.54
1800 MHz 0.271 0.479 0.634 1.39 0.753 1.06 1.57 2.35 3.17
2000 MHz 0.256 0.451 0.597 1.31 0.71 0.996 1.48 2.21 2.96
2500 MHz 0.226 0.40 0.525 1.15 0.627 0.868 1.30 1.92 2.58
3000 MHz 0.204 0.358 0.489 1.04 0.565 0.783 1.16 1.72 ---
Cable Types
RDAF Series RDCL Series
Suitable for a wide range of RF applications requiring multiple frequency Suitable for use in applications where ruggedness for the cable is not
bands as well as harsh environment applications where robust mech- required. This cable is made from an overlapped, thinner copper outer
anical performance and small bending radius are required. conductor over a foam dielectric covering the inner conductor.
Radiating Coaxial Cables 50 Ohm, For Underground Applications – Continued
Standard or Flame & Fire Retardant Jackets
Standard Jacket Flame & Fire Retardant Jacket
The standard jacket material of RDAF & RDCL cable is black The flame & fire retardant jacket material of RDAF & RDCL cable is
polyethylene. flame retardant polyethylene.
The material meets the following requirements. The material meets the following requirements.
Standard Jacket Specified Characteristics FR Jacket Specified Characteristics
IEC 754-1 Halogen Content (Max. 0.2%) IEC 332-1 Flame Spread
IEC 754-2 Non-Corrosive (Min. 4.3 PH Value) ASTM E662 Low Smoke - 0.5t (Max 150)
Conductivity (Max. 100µs / cm) IEC 754-1 & 2 As per Standard Jacket