You are on page 1of 20
oy o EE > on 4 met Bs Baltimore Aircoil Company is a world leader in the design and manufacture of evaporative cooling and heat transfer equipment. Founded in 1938, BAC has 13 manufacturing facilities throughout the world. In China, BAC has two factories in in and sales offices in Beijing, Shanghai and Guangzhou. Independent certitication of cooling tower thermal performance assures ‘owners and operators that they will receive full value from their investment. Performance certification can actually reduce first cost by eliminating the need for “safety factors" when sizing the equipment and the cost of a field acceptance test to verify performance. BAC is ‘committed to providing CT! certification for all its cooling towers. 1SO 9001 Certification confirms BAC's commitment to quality assurance and reaffirms that BAC meets international standards sot, QO) for management principles, designs, closed-loop corrective action, Ky COMPANY training and documentation control in all ofits engineering and manufacturing operations. BAC maintains the industry's most advanced research and product development facility where a broad range of environmental and operating conditions are simulated to evaluate material and component performance. The BAC research and development program has resulted in hundreds of new patents and the most complete line of proven evaporative cooling products in the industry. Series ACT Cooling Towers deliver independently verified, fully rated thermal performance over a wide range of flow and temperature requirements. Standard design features satisfy today's environmental concerns, minimize installation costs, maximize year-tound operating reliability and simplify maintenance requirements. Reliable performance High efficiency, low energy consumption Low installation cost Easy maintenance Long service life Benefits Reliable Performance + Constructed of premium materials & components, the Series ACT cooling towers deliver the highest standard ‘of quality with CT! certified performance. High Efficiency, Low Energy Consumption + Evaporative cooling equipment minimizes the eneray ‘consumption of the entire system because it provides lower operating temperatures. The owner saves money while conserving natural resources and reducing environment impact. « The Series ACT provides the heat rejection required at the lowest possible energy input via: + High efficiency, low horsepower axial fans * High efficiency VersaCross™ Fill provides maximum airfwater contact time at low air pressure drops * High efficiency water distribution system. Low Installation Cost = Optimized Structural Support can minimize the number of support beams or columns. + VersaCross™ Fill can be installed 10 to 12 sheets at a time, compared to the typical "1 sheet at a time”, resulting in dramatic installation labor savings. + Large Capacity Basin is designed to hold more pull- <3 down water volume. Easy Maintenance + Cold Water Basin is sloped toward the center section to facilitate cleaning and to protect against corrosion, scale formation, biological fouling, algae, slime and other micro-organisms. + Water Outlet Strainer is easy to take out for cleaning. + Fill Surface is elevated above the sloped cold water basin to facilitate flushing of dirt and debris from this critical area. * Access Doors on the end walls provide easy access to the unit interior to adjust make-up float valve, clean the cold water basin and strainer, and service the fan drive system. Long Service Life * Sheave & Fan are made of high quality aluminum alloy, providing corrosion-resistance in the moist cooling tower environment. + Corrugated FRP Casing Panels and FRP Hot and Cold Water Basins provide corrosion- abit. + High Quality Components ensure reliable year-round operation. resistance and la ‘tb “Aura Aly Save ‘Gomugalad FRP Casing Panels @ Heavy-Duty Construction » Heavy-gauge hot-dip galvanized steel frame © Optional stainless steel frame structure © Designed to meet high wind loads @ Water Distribution System © Anti-vortexing design, even water distribution © Low pump head gravity distribution basins © Large orifice, 360° non-clog nozzles © Fan Drive System © Corrosion resistant aluminum alloy sheaves © Premium quality, solid backed, multi-groove belt * Heavy-duty bearings * Cooling tower duty fan motor © Low HP Axial Fan © High efficiency * Quiet operation © Corrosion resistant @ ERP Casing Panels © Corrosion resistant © Maintenance free © UV resistant finish @ VersaCross™ Fill Surface with Integral Louvers and Integral Drift Eliminators * High efficiency heat transfer surface * Polyvinyl chloride (PVC) material * Impervious to rot, decay and biological attack @ Hygienic Cold Water Basin © Sloped cold water basin for easy cleaning ‘* Adjustable water make-up assembly © Large capacity basin designed for greater pull- down water volume * Corrosion resistant FRP material of construction @© Access Door © Access doors with handle Accessories Ladder, Safety Cage and Handrails In the event the owner requires easy ‘access to the cooling tower fan deck, the Series ACT Cooling Tower can be furnished with ladders extending from the top of the unit to the base as well as safety cages and handrail packages. All ‘components are designed to meet OSHA requirements. All access to the top of the equipment must be made in accordance with applicable ‘governmental occupational safety standards, Internal Service Platform A galvanized steel internal walk-way Is available to provide a permanent working surface for easy access to the strainer, outlet, and make-up water assembly. For ‘access to the motor and drive assemblies, ‘an internal ladder and upper service platform are available, All components are designed to meet OSHA requirements, Tasdorand Hardale Triomal Senos Platoon Vibration Cutout Switch Vibration cutout switch is available to effectively protect against equipment ‘allure due to excessive vibration of the mechanical equipment system. BAC can provide either a mechanical ’ or solid-state electronic vibration cutout switch to ensure reliable protection. Additional contacts can be provided for either switch type to activate an alarm. Vibration Con Sate Basin Heaters Cooling towers exposed to below freezing ambient temperatures require protection to prevent freezing of the water in the cold water basin when the unit is idle. Electric immersion heaters, which maintain +40°F (4.4°C) water temperature, are a simple and inexpensive way of providing such protection. ACT.0816* AGTO9I7= ACT-1016% ACT-11208 AGT. 1921 ‘ACT-14297 Note: The table data is based on 380V/3 phase/SOHz power and standard, single-cell unit configuration. Engineering Data Do not use for construction. Refer to factory certified dimensions. This catalog includes data current at the time of publication, which should be reconfirmed at the time of purchase. al i 8 oar ETAT Cou Peas FLOW Ce ea keg ee Crm Uc NUMBER TONNAGE (KW) DUS ain tg WATER (i) (rm) (um) AcTosiers| 132 | 22 | 6188s | 1954 | 5734 ‘ACTOSI6TH | 161 4 | 74970 | 19658 | 5745 acTostet | 178 | 55 | asaz2 | 1984 | 5764 2288 |4a1B|a7e4) 2074, 1112 125 | 200 actosetk| 197 | 75 | 91675 | 1007 | 5777 ‘ACT osIEtL | 223 11 | 108590 | 200 | 5824 ‘ACT-OBIEZH | 178 4 | 80778 | 2050 | 5860 acTostezy | 197 | 85 | e946 | 2090 | 5879 AcTostezk | 21a | 7.5 | 9e7e0 | 2112 | see2 | 228e|aa1e|4200)3960/ 1172 | 125 | 200 acToste24 | 247 a1_[tiet1| 2150 | 5909 acTostezm| 274 | 16 [120127 | 2192 | 5972 Notes: 1. Operating weights based on the water level inthe cold water basin at overiow height. £2. Nominal tons of cooling represents @ GPM (0.684 mf) of water from a 25°F (25°C) to 65°F (29.4°C) ata 78°F (25.6°C) entering ‘wot-bub temperature, ‘3. you need mutt-cel towers, consult your local BAC representative. aie’ ial Lue! [EaeeeSes| Reeicon Ercan ead fee Piercccn eons Po Aca) teed eos Poa a) Ceo ir a acTos72J | 29 | 85 | 102965 | 2349 | 8864 ACTOS72K 253 | 75 (112056 | 2363 | 6878 acTost7aL | 26 | 11 [127517 | 2407 | 9022 |2502|s000|4213/0300| 112 | 160 | 200 acTostem|ai7 | 16 [140866 | 2409 | eoae AcTost72N | 330 | 18.5 | 150006 | ates | 6861 acTosi7ek | 266 | 7.5 | 120285| aver | 7002 acTost7at | aoe | t1 [ta6711| ase1_| 7046 AcTost7aM| 336 | 15 | 149666 | 2553 | 7068 |2592|5220|4620|a767| 112 | 160 | 200 AcTost7aN | 360 | 185 | 159675| 2501 | 7108 ‘ACTON730 380 | 22 | 68408 | 2625 | 7140 ACTosT74L | ae | 11 =| 142az2 7168 acTos74m| 363 | 15 | 150805| 2675 | 7190 ACTos74N | 368 | 185 | 1e7472| aris | reas |5e2|sez2|so08|e193| 1/2 | 180 | 200 actosi7a0| 411 | 22 | 176r28| arar | ra62 acroa7ep | 454 | 30 _[194a71| 2003 | 7918 Notes: 1. Operating weight is based on the water level inthe cold water basin at overfiow height. 2. Nominal tons of cooling represents & GPM (0.684 mh) of water from a 25°F (85°C) to 85°F (29.4°C) ata 78°F (25.6°C) entering wot-bulb temperature, 3. you need mult-call towers, consult your local BAC representative. Engineering Data oe pt Ll i ee cia eens Coon enc ae a a eS Rn oo ca) Prati Po OMe JAcT-1018eKm) 323, | 7.5 | 143788 2090 | 8660 ACTIOSHM | 366 | 11 ~~ t62161 | ‘S084 | 8704 ACTIO1eIM | 405 | 15 | 176508 056 | 8726 Jact-ro1en | 434 | 185 | 190581 | 9089 | 8769 2046 |6576|s143|4001 1112 | 200 | 260 Jact-1016-0 | 459 | 22 | 201025 | tos | 8775 lactioiser | 507 | 30 |221017| si6i | e531 jact-io1eo | 643 | a7 | aa6sa1 | saa | a912 Jacr-1o1e5iM | 405 | 11_| vea7a2| 3173 | a84s. JACT-10185.0M) 448 | 15 | 185793 3195 | 8865 ACTION | 479 | 185 | 198213 3228 | 6808 Jact-10185-0 | 607 | 22 | 208095 | 249 | e913 2946/6576 |s560|4698, 1112 | 200 | 260 jact-ro1e5 | so1_| 80 | 229722 000 | 9970 jact-10185-0 | 600 | 37_| 24araz| 3361 | 9051 lact-io1esA | 639 | 45 | 2seane | aa26 | 9096 Notes: 1. Oporating woights based on the water level inthe cold water basin at overiow height ‘2. Nominal tons of cocling represents 3 GPM (0.684 m*/h) of water from a 95°F (35°C) to 85°F (28.4°C) at a 78°F (25.6°C) entering ‘wet-bulb temperature, 3. Ifyou need mut-cel towers, consult your local BAC representative. cf x Ercan ead ee ec ci eons DT Me ieee a ou Poa a) JACT-112054M | 450 11_| 190482| 3707 | 10007 JACT-11205MM) 497 15 | 208624| 8729 | 1002 ACT-I1205NM 633 | 185 | 220552) 3767 | 10067 jacr110s0 | 563 | 22 |paseee| aa02 | 10102 |3949|5979| se00|4721| 1172 | 200 | 250 jacr-ita0se | eas | 80 | 258876 sees | 10189 jacr-i10sq | eer | 7 | arses) aaa | 10240 jacT-iaosA | 711 4 |peeiso| 4018 | 10319 jacr-itss | 744 | 65 |a0a773| 4078 | 10978 JACT-11206MM| 518 15 |217008| 4032 | 10392 JACT-I1206NM 854 | 185 |250460) 4069 | 10369 ACT-112060 | 586 2asto1 | 4105 | 10405 jacT-ite0eP | 648 200405 | 4180 | 10406 | 9349|5979| 6000/5127] +172 | 200 | 250 JAcT-112060 | 094 10547 acT-i1z6n | 740 jacr-1106S | 774 soaz21| 4316 | 10616 16976 43e1_| 10681 1B \& |S /8 8 a 3 g Notes: 1, Operating weight is based on the water level inthe cold water basin at overfow height. 2. Nominal tons of cooling reprasents 3 GPM (0.684 mf) of water rom 2 85°F (95°C) to 85°F (29.4°C) ata 78°F (28.6°C) entering \wot-bulb temperature. ‘3, you need mult-col towers, consult your local BAC representative, 4. The fil of ACT-11205* is single stack anc the fill of AGT-1 1206" is double stack. Engineering Data eee Perc cy cau eens Se na LAcoe GUNN cet eae yy ar aller JacT-13216MM| 563 | 15 | 254837 4535 | 12200 ACT-1S216NM) 609 | 185 [271420 4673, JacT-132160 | 644 lact-raeteP | 719 Jact-isetea | 763 lact-is2ten | 813 Jact-13216S | 651 lacr-isev7-NM| 71 | 1 JacT-13217-0M) 710 jact-rsot7P | 765 Jact-13217-0 | eat Jact-iser7-A | 606 actiserr-s | 937 e172, 112 | 250 | 300 sasiea | 4746 | 12411 520s 4813 | 12478 366084 | 487e | 12549 12581 0664s 4912 | 12577 ‘sae008_5007_| 12672 as7197 5069 | 12734 sr7ee2 5136 | 12801 302258 5201 | 12866 a\a/e/e|s|alelale aly g 3s Notes: 1. Operating weights based on the water level inthe cold water basin at overiow height. 2. Nominal tons of cooling represents 3 GPM (0.684 m°f) of water from a 95°F (95°C) to 85'F (29.4°C) ata 78°F (25.6°C) entering ‘wot bub temperature, ‘3. you need mutt-cel towers, consult your local BAC representative, ce as ea ee A ie Ce ak ACT-'42s70M| eon | 22 | 9S0808| 548 | 14888 cr-idosre | env | 20 |osas06 | 6008 | 14040 noraasra | ast | a7 |aoratt| 6665 | 15060 4340 |e070| 0|soes| 2 | 280 | 300 actsaesra 1018 | 45 |

You might also like