24-00-00

VISUAL CHECK OF AC
FEEDER SEATH CONDITION
AT CONNECTIONS

CHK 10010-001
1

APR05

ZONING DATA
___________
ZONE

ACCESS

: 114
210
212
231
232
511
611
: 114BR 114CR
212KF 212TZ 231XZ 232XZ
511
611

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

AH

___
MEN

_________
MAN-HOURS

24-00-00
CHK 10010-001
2-400 PAGE
1
APR 01/05

24-00-00

VISUAL CHECK OF AC
FEEDER SEATH CONDITION
AT CONNECTIONS

001

CHK 10010-001
2

APR05

___________
PREPARATION
REF. FIG. 240000-RAI-00100
1. MAKE CERTAIN THAT ELECTRICAL GROUND POWER
UNIT IS NOT CONNECTED TO AC AND DC GROUND
POWER RECEPTACLES (ON PANELS 5002VU AND
5000VU) AND THAT ACCESS DOORS 114BR AND
114CR ARE CLOSED.
2. ON PANEL 29VU, MAKE CERTAIN THAT BAT SWITCH
IS IN OFF POSITION.
3. DISPLAY WARNING NOTICE ON PANELS 29VU AND
26VU PROHIBITING ENERGIZATION OF SYSTEM.
NOTE: ALL PANELS OR ACCESS DOOR MENTIONED IN
THIS PROCEDURE MUST BE OPENED.

002

VISUAL CHECK OF HEAT-SHRINK TUBING ON


_____________________________________
ALUMINIUM LUGS
______________
IF LIGHT GREY SHEATH SHOWS TRACES OF BROWN,
HEATING OF ALUMINIUM LUG DUE TO INCORRECT
CRIMPING HAS OCCURED.
IN THIS CASE, LUG MUST BE CHANGED.
CONNECTIONS LISTED BELLOW MUST BE CHECKED.

003

CHECK OF CONNECTIONS IN FLIGHT COMPARTMENT AND


______________________________________________
ELECTRICS RACKS
_______________
REF. FIG. 245000-CHK-00111
1. IN POWER CENTER 120VU :
A. REAR OF PANEL 126VU :
- CONTACTORS 5XU AND 6XU TERMINALS A2, B2
AND C2
B. REAR OF ACCESS DOOR 212TZ :
- CONTACTOR 11XG TERMINALS A, B AND C
*** CONTINUED ***
AH

24-00-00
CHK 10010-001
2-400 PAGE
2
APR 01/05

24-00-00

VISUAL CHECK OF AC
FEEDER SEATH CONDITION
AT CONNECTIONS

004

CHK 10010-001
3

APR05

_____________________________________________
CHECK
OF CONNECTIONS IN PASSENGER COMPARTMENT
REF. FIG. 245000-CHK-00111
A. REAR OF ACCESS DOOR 232XZ (231XZ) :
- TERMINAL STRIP 430VT (431VT) TERMINALS
1, 2 AND 3

005

____________________________
CHECK
OF CONNECTIONS IN WING
REF. FIG. 245000-CHK-00111
A.REAR OF LEADING EDGES 511 (611) NEARNESS
ENGINE NACELLES :
- TERMINAL STRIPS 501VT (600VT) TERMINALS
1, 2 AND 3

006

________________________________
CHECK
OF CONNECTIONS UNDER FLOOR
REF. FIG. 245000-CHK-00111
A.REAR OF ACCESS DOOR 212KF :
- AC EXTERNAL POWER RECEPTACLE 1XG TERMINALS A, B, C AND N
- GROUNDING POINT 127VN

007

________
CLOSE-UP
1. REMOVE WARNING NOTICES ON 29VU AND 26VU.
2. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OR
EQUIPMENT.
NOTE: ALL PANELS OR ACCES DOOR OPENED DURING
THIS PROCEDURE MUST BE CLOSED.
*****

AH

E N D

O F

T E X T

*****

24-00-00
CHK 10010-001
2-400 PAGE
3
APR 01/05

24-00-00
4

AH

CONTROLS AND INDICATING

CHK 10010-001
APR05

24-00-00
CHK 10010-001

2-400

PAGE
4
APR 01/05

24-00-00
5

AH

LOCATION OF NICKELPLATED ALUMINUM LUGS

CHK 10010-001
APR05

24-00-00
CHK 10010-001

2-400

PAGE
5
APR 01/05

24-00-00

VISUAL CHECK OF DC
FEEDER SHEATH CONDITION
AT CONNECTIONS

CHK 10020-001
1

APR05

ZONING DATA
___________
ZONE

ACCESS

: 114
210
232
511
611
: 114BR
211JF
222KF
475AT
511
611

211
251

221

222

231

114CR
211TZ 212UZ 212VZ 213AZ 221AZ 221FF 222CW 222FZ
231XZ 232XZ 251BW
485AT

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

AH

___
MEN

_________
MAN-HOURS

24-00-00
CHK 10020-001
2-400 PAGE
1
APR 01/05

24-00-00

VISUAL CHECK OF DC
FEEDER SHEATH CONDITION
AT CONNECTIONS

001

CHK 10020-001
2

APR05

___________
PREPARATION
REF. FIG. 240000-RAI-00100
1. MAKE CERTAIN THAT ELECTRICAL GROUND POWER
UNIT IS NOT CONNECTED TO AC AND DC GROUND
POWER RECEPTACLES (ON PANELS 5002VU AND
5000VU) AND THAT ACCESS DOORS 114BR AND
114CR ARE CLOSED.
2. ON PANEL 29VU, MAKE CERTAIN THAT BAT SWITCH
IS IN OFF POSITION.
3. DISPLAY WARNING NOTICE ON PANELS 29VU AND
26VU PROHIBITING ENERGIZATION OF SYSTEM.
NOTE: ALL PANELS OR ACCESS DOOR MENTIONED IN
THIS PROCEDURE MUST BE OPENED.

002

VISUAL CHECK OF HEAT-SHRINK TUBING ON


_____________________________________
ALUMINIUM LUGS
______________
IF LIGHT GREY SHEATH SHOWS TRACES OF BROWN,
HEATING OF ALUMINIUM LUG DUE TO INCORRECT
CRIMPING HAS OCCURED.
IN THIS CASE, LUG MUST BE CHANGED.
CONNECTIONS LISTED BELLOW MUST BE CHECKED.

003

CHECK OF CONNECTIONS IN FLIGHT COMPARTMENT AND


______________________________________________
ELECTRICS RACKS
_______________
REF. FIG. 245000-CHK-00121
1. IN POWER CENTER 120VU :
A. REAR OF PANEL 122VU :
- CONTACTORS 10PX, 3GF AND 8GF TERMINAL
A1
- CONTACTORS 11HR, 8PX, 16KF AND 15KF
TERMINAL A2
*** CONTINUED ***
AH

24-00-00
CHK 10020-001
2-400 PAGE
2
APR 01/05

24-00-00

VISUAL CHECK OF DC
FEEDER SHEATH CONDITION
AT CONNECTIONS

CHK 10020-001
3

APR05

B. REAR OF PANEL 121VU :


- TERMINAL STRIP 139VT TERMINAL 9
- TERMINAL STRIP 122VT TERMINAL 2
C. REAR OF ACCES DOOR 212UZ :
- TERMINAL STRIP 725VT TERMINAL 4
D. REAR OF ACCESS DOOR 212VZ :
- TERMINAL STRIP 9PP TERMINAL 1
- SHUNT 39PA TERMINAL (-)
E. REAR OF PANELS 125VU AND 127VU :
- TERMINAL STRIP 5PP TERMINAL 1
F. REAR OF PANELS 124VU AND 128VU :
- TERMINAL STRIP 6PP TERMINAL 1
2. IN LEFT ELECTRONICS RACK 80VU :
A. REAR OF ACCESS DOOR 213AZ :
- BATTERY 21PA TERMINALS (+) AND (-)
B. REAR OF ACCESS DOOR 211TZ :
- GROUNDING POINT 963VN
C. REAR OF ACCESS DOOR 221AZ :
- BATTERY 72PA TERMINALS (+) AND (-)
3. IN RIGHT ELECTRICS RACK 90VU :
A. REAR OF ACCESS DOORS 222KZ AND 222FZ, IN
JUNCTION BOX :
- TERMINAL STRIPS 435VT, 436VT, 437VT AND
438VT TERMINAL 1.
4. REAR OF C/B PANEL 21VU :
- TERMINAL STRIPS 5VT AND 6VT TERMINAL 1
004

_____________________________________________
CHECK
OF CONNECTIONS IN PASSENGER COMPARTMENT
REF. FIG. 245000-CHK-00122
A. REAR OF ACCESS DOORS 232XZ (231XZ) :
- TERMINAL STRIPS 430VT (431VT) TERMINAL
4
B. REAR OF ACCESS DOOR 251BW :
- TERMINAL STRIP 434VT TERMINAL 1
*** CONTINUED ***
AH

24-00-00
CHK 10020-001
2-400 PAGE
3
APR 01/05

24-00-00

VISUAL CHECK OF DC
FEEDER SHEATH CONDITION
AT CONNECTIONS

CHK 10020-001
4

APR05

C. REAR OF ACCESS DOOR 222CW :


- TERMINAL STRIP 440VT TERMINAL 1
005

____________________________
CHECK
OF CONNECTIONS IN WING
REF. FIG. 245000-CHK-00122
A. REAR OF LEADING EDGES 511 (611) NEARNESS
ENGINE NACELLES :
- TERMINAL STRIPS 501VT (600VT) TERMINAL
4
B. REAR OF ACCESS DOORS 475AT (485AT) :
- TERMINAL STRIPS 503VT (602VT) TERMINAL
1

006

________________________________
CHECK
OF CONNECTIONS UNDER FLOOR
REF. FIG. 245000-CHK-00121, 245000-CHK-00122
1. IN FLIGHT COMPARTMENT :
A. REAR OF ACCESS DOOR 211JF :
- GROUNDING POINT 930VN
2. IN PASSENGER COMPARTMENT :
A. REAR OF ACCESS DOOR 221FF :
- FAN 7HR TERMINALS (+) AND (-)
- GROUNDING POINT 108VN

007

________
CLOSE-UP
1. REMOVE WARNING NOTICES ON 29VU AND 26VU.
2. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OR
EQUIPMENT.
NOTE: ALL PANELS OR ACCES DOOR OPENED DURING
THIS PROCEDURE MUST BE CLOSED.
*****

AH

E N D

O F

T E X T

*****

24-00-00
CHK 10020-001
2-400 PAGE
4
APR 01/05

24-00-00
5

AH

CONTROLS AND INDICATING

CHK 10020-001
APR05

24-00-00
CHK 10020-001

2-400

PAGE
5
APR 01/05

24-00-00
6

AH

LOCATION OF NICKELPLATED ALUMINUM LUGS


IN FLIGHT COMPARTMENT

CHK 10020-001
APR05

24-00-00
CHK 10020-001

2-400

PAGE
6
APR 01/05

24-00-00
7

AH

LOCATION OF NICKELPLATED ALUMINUM


LUGS ON AIRCRAFT

CHK 10020-001
APR05

24-00-00
CHK 10020-001

2-400

PAGE
7
APR 01/05

24-00-00

REMOVAL AND INSTALLATION


OF CURRENT TRANSFORMERS
IN 120VU

RAI 10000-002
1

MAR15

ZONING DATA
___________
ZONE
ACCESS

: 212
220
: 212TZ 212VZ 214BZ 214PZ 222CZ 222QZ 222RZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

SPARE

: 02 CT: 3XU-4XU
01 CT: 2XG

AH

___
MEN

_________
MAN-HOURS
01

24-22-80-01-040
24-41-80-01-040

24-00-00
RAI 10000-002
2-400 PAGE
1
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF CURRENT TRANSFORMERS
IN 120VU

001

RAI 10000-002
2

MAR15

_______
CAUTION
VU ASSEMBLIES ARE NOT EQUIPMENT,
INTERCHANGEABILITY BETWEEN AIRCRAFT IS NOT
AUTHORIZED.

002

___________
PREPARATION
REF. FIG. 240000-RAI-00100 (FIG.1)
REF. FIG. 240000-RAI-00103 (FIG.2)
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO THE DC AND AC EXTERNAL POWER RECEPTACLES (ON PANELS 5002VU AND 5000VU
-FIG.1-F AND D) AND THE ACCESS DOORS 114BR
AND 114CR (FIG.1-E AND C) ARE CLOSED
2. ON PANEL 29VU (FIG.1-A) MAKE CERTAIN THAT:
BAT SELECTOR SWITCH 7PA IS IN OFF POSITION
3. DISPLAY A WARNING NOTICE ON PANELS 29VU AND
26VU (FIG.1-B) PROHIBITING POWER SUPPLY TO
SYSTEM
4. ON DC/AC POWER CENTER 120VU OR ON ELECTRONICS RACK 90VU (FIG.2 A AND B AND THE CORRESPONDING FIGURE OF EACH RAI)
120VU: REMOVE ACCESS PANEL 212TZ OR 212VZ
(123VU) OR CIRCUIT BREAKER PANEL 121V
U OR 122VU OR 124VU OR 125VU OR 126VU
OR 127VU OR 128VU OR 129VU OR 130VU
90VU - SIDE SHELF: REMOVE ACCESS PANEL 222RZ
(SHELF 91VU) OR 222QZ (SHELF 91VU OR
92VU OR 93VU) OR 222PZ (SHELF 94VU OR
95VU)
- FRONT SHELF: REMOVE ACCESS PANEL 214
CZ(SHELF 91VU OR 92VU) OR 214BZ(SHELF
93VU OR 94VU OR 95VU)

*** CONTINUED ***


AH

24-00-00
RAI 10000-002
2-400 PAGE
2
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF CURRENT TRANSFORMERS
IN 120VU

003

RAI 10000-002
3

MAR15

_______
REMOVAL
REF.FIG.240000-RAI-00101
1. UNPLUG ELECTRICAL CONNECTOR (5)
2. PUT BLANKING CAP ON ELECTRICAL CONNECTOR
3. REMOVE SCREWS (7) AND WASHERS (6) SECURING
COVER (8)
4. REMOVE COVER
5. REMOVE NUTS (9) AND WASHERS (10) TO DISCONNECT TERMINAL LUGS (11)
6. REMOVE TERMINAL LUGS
7. REMOVE SCREWS (4) AND WASHERS (3) SECURING
CURRENT TRANSFORMER (2)
8. REMOVE CURRENT TRANSFORMER

004

____________
INSTALLATION
REF.FIG.240000-RAI-00101
01. CLEAN AND INSPECT COMPONENT INTERFACE AND/
OR COMPONENT ADJACENT AREA. CHECK FOR CORRECT CONDITION OF ELECTRICAL CONNECTOR
02. INSTALL CURRENT TRANSFORMER (2)
03. INSTALL WASHERS (3) AND SCREWS (4). TIGHTEN
SCREWS
04. INSERT WIRES THROUGH CURRENT TRANSFORMER
05. INSTALL TERMINAL LUGS (11)
06. INSTALL WASHERS (10) AND NUTS (9). TIGHTEN
*** CONTINUED ***
AH

24-00-00
RAI 10000-002
2-400 PAGE
3
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF CURRENT TRANSFORMERS
IN 120VU

RAI 10000-002
4

MAR15

NUTS
NOTE: MARK NUTS (9) WITH RED VARNISH
07. INSTALL COVER (8)
08. INSTALL WASHERS (6) AND SCREWS (7). TIGHTEN
SCREWS
09. REMOVE BLANKING CAP FROM ELECTRICAL CONNECTOR (5)
10. PLUG IN ELECTRICAL CONNECTOR
005

________
CLOSE
UP
REF. FIG. 240000-RAI-00100 (FIG.1)
REF. FIG. 240000-RAI-00103 (FIG.2)
1. ON DC/AC POWER CENTER 12OVU OR ON ELECTRONICS RACK 90VU (FIG.2 A OR B AND THE CORRESPONDING FIGURE OF EACH RAI)
120VU: CLOSE ACCESS PANEL 212TZ OR 212VZ OR
CIRCUIT BREAKER PANEL 121VU OR 122VU
OR 124VU OR 125VU OR 127VU OR 128VU
OR 129VU OR 130VU
90VU - SIDE SHELF: CLOSE ACCESS PANEL 222RZ
OR 222QZ OR 222PZ
- FRONT SHELF: CLOSE ACCESS PANEL 214CZ
OR 214BZ
2. REMOVE THE WARNING NOTICE FROM PANELS 29VU
AND 26VU (FIG.1-A AND B)

006

________________
OPERATIONAL
TEST
THIS TEXT IS NOT APPLICABLE
*****

AH

E N D

O F

T E X T

*****

24-00-00
RAI 10000-002
2-400 PAGE
4
MAR 01/15

24-00-00
5

AH

CONTROLS AND INDICATING

RAI 10000-002
MAR15

24-00-00
RAI 10000-002

2-400

PAGE
5
MAR 01/15

24-00-00
6

AH

REM/INS OF CURRENT
TRANSFORMER

RAI 10000-002
MAR15

24-00-00
RAI 10000-002

2-400

PAGE
6
MAR 01/15

24-00-00
7

AH

ACCESS DOORS, C/B PANELS


& SHELVES (90VU - 120VU)

RAI 10000-002
MAR15

24-00-00
RAI 10000-002

2-400

PAGE
7
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

RAI 10010-002
1

MAR15

ZONING DATA
___________
ZONE
ACCESS

: 212
214
220
: 120VU 121VU 122VU 123VU 124VU 125VU 126VU
212TZ 212VZ 214BZ 214PZ 222CZ 222QZ 222RZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

SPARE

: 04
01
02
02
07
01
02
04
02
02
02
02
02
02
02
01
01
01
01
01
01
02
01
01

AH

___
MEN

_________
MAN-HOURS
01

CNTOR: 5XU-6XU-7XU-8XU
CNTOR:11XG
CNTOR: 2XX-8XX
CNTOR: 7GX - 8GX
CNTOR: 1PA- 2PA- 3PA-58PA
95PA-96PA-97PA
CNTOR: 4PD-13PD
CNTOR: 1DH- 3DH-16DH-18DH
CNTOR: 23PA-42PA
CNTOR: 28HB-29HB
CNTOR: 11HR-17HR
CNTOR: 15KF-16KF
CNTOR: 29PU-30PU
CNTOR: 8PX-10PX
CNTOR: 3GF-8GF
CNTOR: 16PU
CNTOR: 3KG
BAR 9PP FROM 3KG
BAR 8PP FROM 3KG
BAR 7PP FROM 16PU
BAR 2PP FROM 16PU
CNTOR: 1KG-2KG
BAR: 6PP FROM 2KG
BAR: 8PP FROM 2KG

24-22-80-01
24-41-80-01
24-42-80-01
29-24-80-01
24-31-80-01
24-65-80-01
30-61-80-02
24-31-80-01
21-51-80-01
21-23-80-01
61-22-80-02
24-32-80-01
24-47-80-01
29-25-80-01
24-32-80-01
80-11-80-01
24-69-80-03
24-69-80-03
24-69-80-03
24-69-80-03
80-11-80-01
24-69-80-03
24-69-80-03

24-00-00
RAI 10010-002
2-400 PAGE
1
MAR 01/15

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

SPARE

: 01
01
02
01
02
01
02
01
01
01
01

AH

BAR: 5PP FROM 1KG


BAR: 8PP FROM 1KG
CNTOR: 11PU - 12PU
FUSE: 36PU
SHUNT: 22PA - 39PA
CNTOR: 11PG
HALL EFFECT SENSOR:7PU-8PU
HALL EFFECT SENSOR:3PG
BAR 5PP
BAR 6PP
BAR 13PP

24-00-00

RAI 10010-002
2

MAR15

24-69-80-03
24-69-80-03
24-32-80-01
24-32-80-01
24-31-80-01
24-32-80-01
24-32-80-01-030
24-46-80-04-050
24-69-80-03-210
24-69-80-03-200
24-69-80-03-280

24-00-00
RAI 10010-002
2-400 PAGE
2
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

001

RAI 10010-002
3

MAR15

_______
CAUTION
VU ASSEMBLIES ARE NOT EQUIPMENT,
INTERCHANGEABILITY BETWEEN AIRCRAFT IS NOT
AUTHORIZED.

002

_______
REMOVAL
THIS REMOVAL/INSTALLATION PROCEDURE IS APPLICABLE TO THE FOLLOWING ITEMS:
-------ITEM------------------ZONE--ACCESS--FINCONTACTOR-ACW GEN1
- 214
120VU
5XU
CONTACTOR-ACW GEN2
- 214
120VU
6XU
CONTACTOR-BUS TIE 1,ACW
- 214
120VU
7XU
CONTACTOR-BUS TIE 2,ACW
- 214
120VU
8XU
CONTACTOR-EXT PWR,AC
- 214
120VU 11XG
REF.FIG.240000-RAI-00111
1. UNPLUG THE ELECTRICAL CONNECTOR(3)
2. PUT BLANKING CAP ON THE ELECTRICAL CONNECTOR
3. REMOVE SCREWS(6) AND WASHERS(5) RETAINING
COVER(4)
4. REMOVE COVER
5. REMOVE NUTS(7) AND WASHERS(8) TO DISCONNECT
TERMINAL LUGS(9)
6. MARK AND DISCONNECT TERMINAL LUGS(10)
7. REMOVE SCREWS(2) AND WASHERS(1) RETAINING
CONTACTOR(11)
8. REMOVE CONTACTOR

*** CONTINUED ***


AH

24-00-00
RAI 10010-002
2-400 PAGE
3
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

003

RAI 10010-002
4

MAR15

___________
PREPARATION
REF. FIG. 240000-RAI-00100 (FIG.1)
REF. FIG. 240000-RAI-00103 (FIG.2)
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO THE DC AND AC EXTERNAL POWER RECEPTACLES (ON PANELS 5002VU AND 5000VU
-FIG.1-F AND D) AND THE ACCESS DOORS 114BR
AND 114CR (FIG.1-E AND C) ARE CLOSED
2. ON PANEL 29VU (FIG.1-A) MAKE CERTAIN THAT:
BAT SELECTOR SWITCH 7PA IS IN OFF POSITION
3. DISPLAY A WARNING NOTICE ON PANELS 29VU AND
26VU (FIG.1-B) PROHIBITING POWER SUPPLY TO
SYSTEM
4. ON DC/AC POWER CENTER 120VU OR ON ELECTRONICS RACK 90VU (FIG.2 A AND B AND THE CORRESPONDING FIGURE OF EACH RAI)
120VU: REMOVE ACCESS PANEL 212TZ OR 212VZ
(123VU) OR CIRCUIT BREAKER PANEL 121V
U OR 122VU OR 124VU OR 125VU OR 126VU
OR 127VU OR 128VU OR 129VU OR 130VU
90VU - SIDE SHELF: REMOVE ACCESS PANEL 222RZ
(SHELF 91VU) OR 222QZ (SHELF 91VU OR
92VU OR 93VU) OR 222PZ (SHELF 94VU OR
95VU)
- FRONT SHELF: REMOVE ACCESS PANEL 214
CZ(SHELF 91VU OR 92VU) OR 214BZ(SHELF
93VU OR 94VU OR 95VU)

004

_______
REMOVAL
THIS REMOVAL/INSTALLATION PROCEDURE IS APPLICABLE TO THE FOLLOWING ITEMS:
---------ITEM----------------ZONE--ACCESS--FINCNTR-SVCE BUS XFR, ACW
- 212
121VU
2XX
CNTR-SVCE BUS, ACW
- 212
121VU
8XX
*** CONTINUED ***
AH

24-00-00
RAI 10010-002
2-400 PAGE
4
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

RAI 10010-002
5

MAR15

REF.FIG.240000-RAI-00112
01. REMOVE SCREWS (7) RETAINING COVERS (6 AND
5)
02. REMOVE COVER (6)
03. REMOVE NUTS (11) AND WASHERS (12) TO DISCONNECT TERMINAL LUGS (13)
04. MARK AND DISCONNECT TERMINAL LUGS (13)
05. REMOVE COVER (5)
06. REMOVE NUTS (4) AND WASHERS (3) TO DISCONNECT TERMINAL LUGS (2)
07. MARK AND DISCONNECT TERMINAL LUGS (2)
08. REMOVE SCREWS(8) AND WASHERS (9) TO DISCONNECT TERMINAL LUGS (10)
09. MARK AND DISCONNECT TERMINAL LUGS (10)
10. REMOVE SCREWS (14) AND WASHERS (15) RETAINING CONTACTOR (1)
11. REMOVE CONTACTOR
005

_______
REMOVAL
THIS REMOVAL/INSTALLATION PROCEDURE IS APPLICABLE TO THE FOLLOWING ITEMS:
---------ITEM----------------ZONE--ACCESS--FINCONTACTOR-PUMP, BLUE HYD
SYS
- 212
126VU
7GX
CONTACTOR-PUMP, GREEN HYD
SYS
- 212
126VU
8GX
REF.FIG.240000-RAI-00113
*** CONTINUED ***
AH

24-00-00
RAI 10010-002
2-400 PAGE
5
MAR 01/15

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

24-00-00

RAI 10010-002
6

MAR15

01. REMOVE SCREWS (7) RETAINING COVERS (6 AND


5)
02. REMOVE COVER (6)
03. REMOVE NUTS (11) AND WASHERS (12) TO DISCONNECT TERMINAL LUGS (13)
04. MARK AND DISCONNECT TERMINAL LUGS (13)
05. REMOVE COVER (5)
06. REMOVE NUTS (14) AND WASHERS (15) TO DISCONNECT TERMINAL LUGS (16)
07. MARK AND DISCONNECT TERMINAL LUGS (16)
08. REMOVE SCREWS (4 AND 8) AND WASHERS (3 AND
9) TO DISCONNECT TERMINAL LUGS (2 AND 10)
09. MARK AND DISCONNECT TERMINAL LUGS(2 AND 10)
10. REMOVE SCREWS (17) AND WASHERS (18) RETAINING CONTACTOR (1)
11. REMOVE CONTACTOR
006

_______
REMOVAL
THIS REMOVAL/INSTALLATION PROCEDURE IS APPLICABLE TO THE FOLLOWING ITEMS:
------ITEM-------------------ZONE--ACCESS--FINCONTACTOR-MAIN BUSES TRANSFER, DC
- 212
123VU
1PA
CONTACTOR-BUS1/HOT MAIN
BAT BUS TRANSFER - 212
123VU
2PA
CONTACTOR-MAIN BUSES/HOT
MAIN BAT BUS
TRANSFER
- 212
123VU
3PA
CONTACTOR-MAIN BUSES/HOT
EMER BAT BUS
*** CONTINUED ***
AH

24-00-00
RAI 10010-002
2-400 PAGE
6
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

RAI 10010-002
7

TRANSFER
- 212
CONTACTOR -EMER BUS
TRANSFER/HOT
EMER BAT
BUS-TRU
- 212
CONTACTOR -ESS/STBY BUSES
TRANSFER/HOT
MAIN BAT
BUS-TRU
- 212
CONTACTOR -INV 1 TRANSFER/
BUS 1-TRU
- 212
CONTACTOR-STBY BUS, DC
- 212
CONTACTOR-STAT INV OVRD XFR- 212

123VU

MAR15

58PA

123VU

95PA

123VU

96PA

123VU 97PA
123VU
4PD
123VU 13PD

REF.FIG.240000-RAI-00121
1. REMOVE CAPTIVE SCREWS (6) SECURING CONTACTOR
(7)
2. REMOVE CONTACTOR WITH CARE NOT TO DAMAGE THE
ELECTRICAL CONNECTOR (5)
3. REMOVE NUTS (8) AND WASHERS (9) TO DISCONNECT TERMINAL LUGS (10)
4. MARK AND DISCONNECT TERMINAL LUGS
5. REMOVE SCREW (2) RETAINING PROTECTIVE COVER
(1)
6. REMOVE PROTECTIVE COVER
7. REMOVE NUTS (13) AND WASHERS (12) TO DISCONNECT TERMINAL LUGS (11)
8. MARK AND DISCONNECT TERMINAL LUGS
9. REMOVE BUSBAR (14) (RE-USED).
NOTE: PROTECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA
*** CONTINUED ***
AH

24-00-00
RAI 10010-002
2-400 PAGE
7
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

007

RAI 10010-002
8

MAR15

_______
REMOVAL
THIS REMOVAL/INSTALLATION PROCEDURE IS APPLICABLE TO THE FOLLOWING ITEMS :
--------ITEM-----------------ZONE--ACCESS--FINCONTACTOR-MAIN BAT CHARGE - 214
123VU 23PA
CONTACTOR-EMER BAT CHARGE - 214
123VU 42PA
CONTACTOR-BLADES 1, 3 AND 5
DEICING, PROP 1 - 214
120VU
3DH
CONTACTOR-BLADES 2, 4 AND 6
DEICING, PROP 1 - 214
120VU
1DH
CONTACTOR-BLADES 1, 3 AND 5
DEICING, PROP 2 - 214
120VU 18DH
CONTACTOR-BLADES 2, 4 AND 6
DEICING, PROP 2 - 214
120VU 16DH
REF.FIG.240000-RAI-00122
1. REMOVE SCREWS (4) AND WASHERS (3) TO DISCONNECT TERMINAL LUGS (2)
2. MARK AND DISCONNECT TERMINAL LUGS
3. REMOVE NUTS (8) AND WASHERS (7) TO DISCONNECT TERMINAL LUGS (6)
4. MARK AND DISCONNECT TERMINAL LUGS
5. REMOVE CLAMP (5) RETAINING CONTACTOR (1)
6. REMOVE CONTACTOR

008

_______
REMOVAL
THIS REMOVAL PROCEDURE IS APPLICABLE TO THE
FOLLOWING ITEMS:
----ITEM---------------------ZONE--ACCESS--FINCONTACTOR-RECIRCULATION FAN,
SYS2
- 212
122VU 28HB
CONTACTOR-RECIRCULATION FAN,
SYS1
- 212
122VU 29HB
*** CONTINUED ***
AH

24-00-00
RAI 10010-002
2-400 PAGE
8
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

CONTACTOR-ELECTRONICS RACK
EXTRACTION FAN
BUS 2 PWR
CONTACTOR-ELECTRONICS RACK
EXTRACTION FAN
BUS 1 PWR
RELAY-FEATH PUMP PWR, PROP
(ENG1)
RELAY-FEATH PUMP PWR, PROP
(ENG2)
CONTACTOR-UTILITY BUS1
CONTACTOR-UTILITY BUS2
CONTACTOR-DC SERVICE BUS
TRANSFER
CONTACTOR-DC SERVICE BUS

RAI 10010-002
9

212

122VU

11HR

1
2
-

212

122VU

17HR

212

122VU

15KF

212
212
212

122VU
122VU
122VU

16KF
29PU
30PU

212
212

121VU
121VU

8PX
10PX

MAR15

REF.FIG.240000-RAI-00130
1. UNPLUG ELECTRICAL CONNECTOR (8)
2. PUT BLANKING CAP ON ELECTRICAL CONNECTOR
3. REMOVE NUTS (4),(5) AND WASHERS (3),(6) TO
DISCONNECT TERMINAL LUGS (2),(7)
4. MARK AND DISCONNECT TERMINAL LUGS (2),(7)
5. REMOVE SCREWS (9) AND WASHERS (10) RETAINING
CONTACTOR
6. REMOVE CONTACTOR (1)
NOTE: PROTECT COMPONENT INTERFACE AND/OR COMPONENT ADJACENT AREA
009

_______
REMOVAL
THIS REMOVAL/INSTALLATION PROCEDURE IS APPLICABLE TO THE FOLLOWING ITEMS:
------ITEMS------------------ZONE--ACCESS--FINCONTACTOR-PUMP GND PWR,
*** CONTINUED ***
AH

24-00-00
RAI 10010-002
2-400 PAGE
9
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

AUXILIARY SYS
CONTACTOR-PUMP MAIN PWR,
AUXILIARY SYS

RAI 10010-002
10

212

122VU

3GF

212

122VU

8GF

MAR15

REF.FIG.240000-RAI-00131
1. REMOVE NUTS (12) AND WASHERS (11) TO DISCONNECT TERMINAL LUGS (10)
2. MARK AND DISCONNECT TERMINAL LUGS (10)
3. REMOVE NUTS (1) AND WASHERS (2) TO DISCONNECT TERMINAL LUGS (3)
4. MARK AND DISCONNECT TERMINAL LUGS (3)
5. REMOVE SCREWS (4) AND WASHERS (5) TO DISCONNECT TERMINAL LUGS (6)
6. MARK AND DISCONNECT TERMINAL LUGS (6)
7. REMOVE SCREWS (9) AND WASHERS (8) RETAINING
CONTACTOR
8. REMOVE CONTACTOR (7)
NOTE: PROTECT COMPONENT INTERFACE AND/OR COMPONENT ADJACENT AREA
010

_______
REMOVAL
THIS REMOVAL/INSTALLATION PROCEDURE IS APPLICABLE TO THE FOLLOWING ITEMS:
--------ITEM-----------------ZONE--ACCESS--FINCONTACTOR-BUS TIE 2, DC
- 212
123VU 16PU
CONTACTOR-MAIN BAT START
ENG 1 & 2
- 212
123VU
3KG
REF.FIG.240000-RAI-00132
1. REMOVE NUTS (4) SECURING TERMINAL STRIPS (1
*** CONTINUED ***
AH

24-00-00
RAI 10010-002
2-400 PAGE
10
MAR 01/15

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

24-00-00

RAI 10010-002
11

MAR15

AND 3)
2. REMOVE CAPTIVE SCREWS (2) RETAINING CONTACTOR (5)
3. REMOVE CONTACTOR WITH CARE TO NOT DAMAGE THE
ELECTRICAL CONNECTOR (6)
011

_______
REMOVAL
THIS REMOVAL/INSTALLATION PROCEDURE IS APPLICABLE TO THE FOLLOWING ITEMS:
--------ITEM-----------------ZONE--ACCESS--FINCONTACTOR-START, ENG 1
- 212
123VU
1KG
CONTACTOR-START, ENG 2
- 212
123VU
2KG
REF.FIG.240000-RAI-00133
1. REMOVE NUTS (4) SECURING TERMINAL STRIPS (1
AND 3)
2. REMOVE CAPTIVE SCREWS (2) RETAINING CONTACTOR (5)
3. REMOVE CONTACTOR WITH CARE TO NOT DAMAGE THE
ELECTRICAL CONNECTOR (6)

012

_______
REMOVAL
THIS REMOVAL/INSTALLATION PROCEDURE IS
APPLICABLE TO THE FOLLOWING ITEMS:
------ITEMS-------------------ZONE--ACCESS--FIN
CONTACTOR-GENERATOR,DC
212 123VU 11PU
CONTACTOR-GENERATOR,DC
212 123VU 12PU
REF. FIG. : 240000-RAI-00135
1. REMOVE NUTS AND WASHER (2).
2. REMOVE CAPTIVE SCREWS (1) RETAINING
CONTACTOR (3).
3. REMOVE CONTACTOR WITH CARE TO NOT DAMAGE
THE ELECTRICAL CONNECTOR (4).
*** CONTINUED ***
AH

24-00-00
RAI 10010-002
2-400 PAGE
11
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

013

RAI 10010-002
12

MAR15

_______
REMOVAL
THIS REMOVAL/INSTALLATION PROCEDURE IS
APPLICABLE TO THE FOLLOWING ITEMS:
------ITEM---------------ZONE--ACCESS----FIN
FUSE-BUS TIE, DC GEN
212
123VU
36PU
1. REMOVE NUTS RETAINING FUSE.
2. REMOVE FUSE.

014

_______
REMOVAL
THIS REMOVAL/INSTALLATION PROCEDURE IS
APPLICABLE TO THE FOLLOWING ITEMS:
----ITEMS----------ZONE----ACCESS----FIN----SHUNT-MAIN BAT
212
123VU
22PA
SHUNT-EMER BAT
212
123VU
39PA
REF.
1.
2.
3.
4.

FIG. : 240000-RAI-00134
REMOVE SCREWS (2) TO DISCONNECT CABLES.
MARK AND DISCONNECT CABLES.
REMOVE STUDS (1) RETAINING SHUNT (3).
REMOVE SHUNT (3).

NOTE: PROTECT COMPONENT INTERFACE AND/OR


COMPONENT ADJACENT AREA.
015

_______
REMOVAL
THIS REMOVAL/INSTALLATION PROCEDURE IS
APPLICABLE TO THE FOLLOWING ITEMS:
------ITEMS-------------------ZONE--ACCESS--FIN
CONTACTOR-EXTERNAL POWER, DC
212 123VU 11PG
REF. FIG. : 240000-RAI-00136
1. REMOVE NUTS AND WASHER (2).
2. REMOVE CAPTIVE SCREWS (1) RETAINING
CONTACTOR (3).
3. REMOVE CONTACTOR WITH CARE TO NOT DAMAGE
*** CONTINUED ***
AH

24-00-00
RAI 10010-002
2-400 PAGE
12
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

RAI 10010-002
13

MAR15

THE ELECTRICAL CONNECTOR (4).


016

_______
REMOVAL
THIS REMOVAL/INSTALLATION PROCEDURE IS
APPLICABLE TO THE FOLLOWING ITEMS:
---------ITEM-----------ZONE--ACCESS--FIN-HALL EFF SNSR/DC GEN1 - 212
123VU
7PU
HALL EFF SNSR/DC GEN2 - 212
123VU
8PU
HALL EFF SNSR/EXT PWR - 212
123VU
3PG
REF.FIG.240000-REM-00050
1. UNPLUG ELECTRICAL CONNECTOR (13)
2. PUT BLANKING CAP ON ELECTRICAL CONNECTOR
3. REMOVE SCREW (1), WASHER (4) AND NUT (5) SECURING TERMINAL STRIP (3 OR 15)
4. REMOVE SCREW (7), WASHER (8) AND NUT (9) SECURING TERMINAL STRIP 6PP (6) OR 5PP (5) OR
13PP (10)
5. REMOVE TERMINAL STRIP (2 OR 14 OR 11)
6. UNSCREW CAPTIVE SCREWS (16) RETAINING HALL
EFFECT SENSOR (17)

017

____________
INSTALLATION
REF.FIG.240000-RAI-00111
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA.
2. INSTALL CONTACTOR(11)
3. INSTALL WASHERS(1) AND SCREWS(2). TIGHTEN
SCREWS
4. CONNECT WIRING(10) USING TERMINAL LUGS(9)
*** CONTINUED ***
AH

24-00-00
RAI 10010-002
2-400 PAGE
13
MAR 01/15

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

24-00-00

RAI 10010-002
14

MAR15

5. INSTALL WASHERS(8) AND NUTS(7). TIGHTEN NUTS


(TIGHTENING TORQUE VALUE: 0,25 MDAN/22 LBF
TO 0,30 MDAN/26,6 LBF)
6. INSTALL COVER(4)
7. INSTALL WASHERS(5) AND SCREWS(6). TIGHTEN
SCREWS
8. REMOVE BLANKING CAP FROM ELECTRICAL CONNECTOR(3)
9. PLUG ELECTRICAL CONNECTOR
018

____________
INSTALLATION
REF.FIG.240000-RAI-00112
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA
2. INSTALL CONTACTOR (1)
3. INSTALL WASHERS (15) AND SCREWS(14). TIGHTEN
SCREWS
4. INSTALL TERMINAL LUGS (10), WASHERS (9) AND
SCREWS(8). TIGHTEN SCREWS (TIGHTENING TORQUE
VALUE:0,02 TO 0,03 MDAN-1,7 TO 2,6 LBF X IN)
5. INSTALL TERMINAL LUGS (2), WASHERS (3) AND
NUTS (4). TIGHTEN NUTS (TIGHTENING TORQUE
VALUE:0,21 TO 0,28 MDAN - 18,6 TO 24,7 LBF
X IN)
NOTE: MARK NUTS (4) WITH RED VARNISH
6. INSTALL COVER (5)
7. INSTALL TERMINAL LUGS (13), WASHERS (12) AND
NUTS (11). TIGHTEN NUTS (TIGHTENING TORQUE
VALUE:0,21 TO 0,28 MDAN-18,6 TO 24,7 LBF X
*** CONTINUED ***
AH

24-00-00
RAI 10010-002
2-400 PAGE
14
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

RAI 10010-002
15

MAR15

IN)
NOTE: MARK NUTS (11) WITH RED VARNISH
8. INSTALL COVER (6) AND SCREWS (7). TIGHTEN
SCREWS
019

____________
INSTALLATION
REF.FIG.240000-RAI-00113
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA
2. INSTALL CONTACTOR (1)
3. INSTALL WASHERS (18) AND SCREWS(17). TIGHTEN
SCREWS
4. INSTALL TERMINAL LUGS (2 AND 10), WASHERS (3
AND 9) AND SCREWS (4 AND 8). TIGHTEN SCREWS
(TIGHTENING TORQUEVALUE: 0,03 TO 0,05 MDAN
- 3,3 TO 4,4 LBF X IN)
5. INSTALL TERMINAL LUGS (16), WASHERS (15) AND
NUTS (14). TIGHTEN NUTS (TIGHTENING TORQUE
VALUE: 0,21 TO 0,28 MDAN - 18,6 TO 24,7 LBF
X IN)
NOTE: MARK NUTS (14) WITH RED VARNISH
6. INSTALL COVER (5)
7. INSTALL TERMINAL LUGS (13), WASHERS (12) AND
NUTS (11). TIGHTEN NUTS (TIGHTENING TORQUE
VALUE: 0,21 TO 0,28 MDAN -18,6 TO 24,7 LBF X
IN)
NOTE: MARK NUTS (11) WITH RED VARNISH
8. INSTALL COVER (6) AND SCREWS (7). TIGHTEN
SCREWS

*** CONTINUED ***


AH

24-00-00
RAI 10010-002
2-400 PAGE
15
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

020

RAI 10010-002
16

MAR15

____________
INSTALLATION
REF.FIG.240000-RAI-00121
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA
2. INSTALL BUSBAR (14) PREVIOUSLY REMOVED.
3. INSTALL TERMINAL LUGS (11), WASHERS (12) AND
NUTS (13). TIGHTEN NUTS(TIGHTENING TORQUE VA
LUE: 0,2 MDAN/17 LBF.IN NOM TO 0,27 MDAN/
24 LBF.IN MAX)
4. INSTALL PROTECTIVE COVER (1) AND SCREW (2).
TIGHTEN SCREW
5. INSTALL TERMINAL LUGS (10), WASHERS (9) AND
NUTS (8). TIGHTEN NUTS (TIGHTENING TORQUE
VALUE: 0,35 MDAN/30 LBF.IN NOM)
6. INSTALL CONTACTOR (7) WITH ITS ELECTRICAL
CONNECTOR (5)
7. TIGHTEN CAPTIVE SCREWS (6)
NOTE: MARK NUTS (8) WITH RED VARNISH

021

____________
INSTALLATION
REF.FIG.240000-RAI-00122
1. INSTALL CONTACTOR(1)
2. INSTALL AND TIGHTEN CLAMP(5)
3. CONNECT TERMINAL LUGS(6) AND INSTALL WASHERS(7) AND NUTS(8). TIGHTEN NUTS (TIGHTENING TORQUE VALUE: 0,25 TO 0,30 MDAN/ 22 TO
26,5 LBF X IN)
*** CONTINUED ***
AH

24-00-00
RAI 10010-002
2-400 PAGE
16
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

RAI 10010-002
17

MAR15

4. CONNECT TERMINAL LUGS(2) AND INSTALL WASHERS


(3) AND SCREWS(4). TIGHTEN SCREWS (TIGHTENING TORQUE VALUE: 0,049 TO 0,062 MDAN/ 4,3
TO 5,5 LBF X IN)
NOTE: MARK NUTS(8) WITH RED VARNISH
022

____________
INSTALLATION
REF.FIG.240000-RAI-00130
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA. CHECK FOR CORRECT
CONDITION OF ELECTRICAL CONNECTOR
2. INSTALL CONTACTOR (1)
3. INSTALL WASHERS (10) AND SCREWS (9). TIGHTEN
SCREWS
4. INSTALL (ON CONTACTS X1 AND X2) TERMINAL
LUGS (2), WASHERS (3) AND NUTS (4). TIGHTEN
NUTS AND PROVIDE THESE ONES WITH PROTECTIVE
INSULATION. (TIGHTENING TORQUE VALUE: 0,07
MDAN/6 LBF X IN NOM)
5. INSTALL (ON CONTACTS A1 AND A2) TERMINAL
LUGS (7), WASHERS (6) AND NUTS (5). TIGHTEN
NUTS (TIGHTENING TORQUE VALUE: 0,5 MDAN/
45 LBF.IN NOM)
6. REMOVE BLANKING CAP FROM ELECTRICAL CONNECTOR (8)
7. PLUG IN ELECTRICAL CONNECTOR
NOTE: MARK NUTS (4)(5) WITH RED VARNISH

*** CONTINUED ***


AH

24-00-00
RAI 10010-002
2-400 PAGE
17
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

023

RAI 10010-002
18

MAR15

____________
INSTALLATION
REF.FIG.240000-RAI-00131
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA
2. INSTALL CONTACTOR (7)
3. INSTALL WASHERS (8) AND SCREWS (9). TIGHTEN
SCREWS
4. INSTALL TERMINAL LUGS (6), WASHERS (5) AND
SCREWS (4). TIGHTEN SCREWS
5. INSTALL TERMINAL LUGS (3), WASHERS (2) AND
NUTS (1). TIGHTEN NUTS (TIGHTENING TORQUE
VALUE: 0,07 MDAN/6 LBF X IN NOM)
6. INSTALL TERMINALS LUGS (10), WASHERS(11) AND
NUTS(12). TIGHTEN NUTS (TIGHTENING TORQUE
VALUE: 0,5 MDAN/45 LBF.IN NOM)
NOTE: MARK NUTS (12)(1) WITH RED VARNISH

024

____________
INSTALLATION
REF.FIG.240000-RAI-00132
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA. CHECK FOR CORRECT
CONDITION OF ELECTRICAL CONNECTORS
2. INSTALL CONTACTOR (5) WITH ITS ELECTRICAL
CONNECTOR (6)
3. TIGHTEN CAPTIVE SCREWS (2)
4. -(16PU) INSTALL TERMINAL STRIPS(1)(2PP) AND
(3)(7PP) AND NUTS(4). TIGHTEN NUTS
-( 3KG) INSTALL TERMINAL STRIPS (1)(8PP) AND
*** CONTINUED ***
AH

24-00-00
RAI 10010-002
2-400 PAGE
18
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

RAI 10010-002
19

MAR15

(3)(9PP) AND NUTS (4). TIGHTEN NUTS


(TIGHTENING TORQUE VALUE: 1,35 TO 1,45 MDAN
- 119 TO 128 LBF X IN)
025

____________
INSTALLATION
REF.FIG.240000-RAI-00133
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA. CHECK FOR CORRECT
CONDITION OF ELECTRICAL CONNECTORS
2. INSTALL CONTACTOR (5) WITH ITS ELECTRICAL
CONNECTOR (6)
3. TIGHTEN CAPTIVE SCREWS (2)
4. -( 2KG) INSTALL TERMINAL STRIPS (1)(8PP) AND
(3)(6PP) AND NUTS (4). TIGHTEN NUTS
-( 1KG) INSTALL TERMINAL STRIPS (1)(5PP) AND
(3)(8PP) AND NUTS(4). TIGHTEN NUTS
(TIGHTENING TORQUE VALUE: 1,35 TO 1,45 MDAN
- 119 TO 128 LBF X IN)

026

____________
INSTALLATION
REF. FIG. 240000-RAI-00135
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/
OR COMPONENT ADJACENT AREA. CHECK FOR
CORRECT CONDITION OF ELECTRICAL CONNECTORS.
2. INSTALL CONTACTOR (3) WITH ITS ELECTRICAL
CONNECTOR (4).
3. TIGHTEN CAPTIVE SCREWS (1).
4. INSTALL NUTS AND WASHER (2) PREVIOUSLY
REMOVED. TIGHTEN NUTS (TIGHTENING TORQUE
VALUE : 1,4 MDAN - 124 LBF.IN).

027

____________
INSTALLATION
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA.
*** CONTINUED ***
AH

24-00-00
RAI 10010-002
2-400 PAGE
19
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

RAI 10010-002
20

MAR15

2. INSTALL FUSE.
3. INSTALL NUTS. TIGHTEN NUTS (TIGHTENING
TORQUE VALUE: 1,05 TO 1,15 MDAN/93 TO 102
LBF.IN).
028

____________
INSTALLATION
REF. FIG. 240000-RAI-00134
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/
OR COMPONENT ADJACENT AREA.
2. INSTALL SHUNT (3).
3. INSTALL STUDS (1). TIGHTEN STUDS (TIGHTENING
TORQUE VALUE: 1,1 MDAN/97 LBF.IN NOM).
4. INSTALL CABLES AND TIGHTEN SCREWS (2)
(TIGHTENING TORQUE VALUE: 1,05 TO 1,15 MDAN/
93 TO 102 LBF.IN).
NOTE: MARK SCREWS (2) WITH RED VANISH.

029

____________
INSTALLATION
REF. FIG. 240000-RAI-00136
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/
OR COMPONENT ADJACENT AREA. CHECK FOR
CORRECT CONDITION OF ELECTRICAL CONNECTORS.
2. INSTALL CONTACTOR (3) WITH ITS ELECTRICAL
CONNECTOR (4).
3. TIGHTEN CAPTIVE SCREWS (1).
4. INSTALL NUTS AND WASHER (2).TIGHTEN NUTS
(TIGHTENING TORQUEVALUE : 1,4 MDAN 124 LBF.IN).

030

____________
INSTALLATION
REF.FIG.240000-RAI-00150
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA.
*** CONTINUED ***
AH

24-00-00
RAI 10010-002
2-400 PAGE
20
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF EQUIPMENT IN 120VU

RAI 10010-002
21

MAR15

2. INSTALL HALL EFFECT SENSOR (17) ON ITS SUPPORT AND SCREW CAPTIVE SCREWS (16)
3. INSTALL TERMINAL STRIP (2 OR 14 OR 11) THROUGH SENSOR
4. INSTALL SCREW (1 AND 7), WASHER (4 AND 8)
AND NUT (5 AND 9) SECURING TERMINAL STRIP TO
LATERAL ONES (3 OR 15 AND 6 OR 12 OR 10)
5. REMOVE BLANKING CAP FROM ELECTRICAL CONNECTOR (13)
6. PLUG IN ELECTRICAL CONNECTOR
031

________
CLOSE
UP
REF. FIG. 240000-RAI-00100 (FIG.1)
REF. FIG. 240000-RAI-00103 (FIG.2)
1. ON DC/AC POWER CENTER 12OVU OR ON ELECTRONICS RACK 90VU (FIG.2 A OR B AND THE CORRESPONDING FIGURE OF EACH RAI)
120VU: CLOSE ACCESS PANEL 212TZ OR 212VZ OR
CIRCUIT BREAKER PANEL 121VU OR 122VU
OR 124VU OR 125VU OR 127VU OR 128VU
OR 129VU OR 130VU
90VU - SIDE SHELF: CLOSE ACCESS PANEL 222RZ
OR 222QZ OR 222PZ
- FRONT SHELF: CLOSE ACCESS PANEL 214CZ
OR 214BZ
2. REMOVE THE WARNING NOTICE FROM PANELS 29VU
AND 26VU (FIG.1-A AND B)

032

________________
OPERATIONAL
TEST
THIS TEXT IS NOT APPLICABLE
*****

AH

E N D

O F

T E X T

*****

24-00-00
RAI 10010-002
2-400 PAGE
21
MAR 01/15

24-00-00
22

AH

CONTROLS AND INDICATING

RAI 10010-002
MAR15

24-00-00
RAI 10010-002

2-400

PAGE
22
MAR 01/15

24-00-00
23

AH

ACCESS DOORS, C/B PANELS


& SHELVES (90VU - 120VU)

RAI 10010-002
MAR15

24-00-00
RAI 10010-002

2-400

PAGE
23
MAR 01/15

24-00-00
24

AH

REM/INS OF CONTACTORS
AND RELAYS IN 120VU

RAI 10010-002
MAR15

24-00-00
RAI 10010-002

2-400

PAGE
24
MAR 01/15

24-00-00
25

AH

REM/INS OF CONTACTORS
AND RELAYS IN 120VU

RAI 10010-002
MAR15

24-00-00
RAI 10010-002

2-400

PAGE
25
MAR 01/15

24-00-00
26

AH

REM/INS OF CONTACTORS
AND RELAYS IN 120VU

RAI 10010-002
MAR15

24-00-00
RAI 10010-002

2-400

PAGE
26
MAR 01/15

24-00-00
27

AH

RAI OF CONTACTORS
AND RELAYS IN 120VU

RAI 10010-002
MAR15

24-00-00
RAI 10010-002

2-400

PAGE
27
MAR 01/15

24-00-00
28

AH

REM/INS OF CNTOR
OF RELAY IN 120VU

RAI 10010-002
MAR15

24-00-00
RAI 10010-002

2-400

PAGE
28
MAR 01/15

24-00-00
29

AH

REM/INS OF CNTOR
AND RELAY IN 120VU

RAI 10010-002
MAR15

24-00-00
RAI 10010-002

2-400

PAGE
29
MAR 01/15

24-00-00
30

AH

REM/INS OF CNTOR
AND RELAY IN 120VU

RAI 10010-002
MAR15

24-00-00
RAI 10010-002

2-400

PAGE
30
MAR 01/15

24-00-00
31

AH

REM/INS OF CNTOR
AND RELAY IN 120VU

RAI 10010-002
MAR15

24-00-00
RAI 10010-002

2-400

PAGE
31
MAR 01/15

24-00-00
32

AH

REM/INS OF CNTOR
AND RELAY IN 120VU

RAI 10010-002
MAR15

24-00-00
RAI 10010-002

2-400

PAGE
32
MAR 01/15

24-00-00
33

AH

RAI OF HALL EFFECT


SENSOR

RAI 10010-002
MAR15

24-00-00
RAI 10010-002

2-400

PAGE
33
MAR 01/15

24-00-00
34

AH

REM/INS OF CNTOR AND


RELAY IN 120VU

RAI 10010-002
MAR15

24-00-00
RAI 10010-002

2-400

PAGE
34
MAR 01/15

24-00-00
35

AH

REM/INS OF SHUNTS IN 123


VU

RAI 10010-002
MAR15

24-00-00
RAI 10010-002

2-400

PAGE
35
MAR 01/15

24-00-00
36

AH

REM/INS OF CONTACTORS
IN 120VU

RAI 10010-002
MAR15

24-00-00
RAI 10010-002

2-400

PAGE
36
MAR 01/15

24-00-00

REMOVAL AND INSTALLATION


OF CONTACTORS AND RELAYS
IN FLIGHT COMPARTMENT

RAI 10040-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 110
210
212
: 114BR 121VU 126VU
211FZ 212FZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELECTRIC

_________
MAN-HOURS
01

ELAPSED TIME

SPARE

: 02 CONTACTOR: 27DG-28DG
02 CONTACTOR: 30DG-31DG

30-42-80-03-040
30-42-80-XX-XXX

: OPERATIONAL TEST OF
WINDSHIELD HEATING

30-42-00-OPT-10000

PUBLICATION
___________
JIC

AH

24-00-00
RAI 10040-001
2-400 PAGE
1
APR 01/05

24-00-00

REMOVAL AND INSTALLATION


OF CONTACTORS AND RELAYS
IN FLIGHT COMPARTMENT

001

RAI 10040-001
2

APR05

_______
CAUTION
VU ASSEMBLIES ARE NOT EQUIPMENT,
INTERCHANGEABILITY BETWEEN AIRCRAFT IS NOT
AUTHORIZED.

002

___________
PREPARATION
REF.FIG.240000-RAI-00100 (FIG.1)
REF.FIG.240000-RAI-00140 (FIG.2)
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO THE DC EXTERNAL POWER RECEPTACLES (ON PANEL 5002VU / FIG.1-F)AND THE
ACCESS DOOR 114BR (FIG.1-E) IS CLOSED
2. ON PANEL 29VU (FIG.1-A) MAKE CERTAIN THAT:
BAT SELECTOR SWITCH 7PA IS IN OFF POSITION
3. DISPLAY A WARNING NOTICE ON PANEL 29VU PROHIBITING POWER SUPPLY TO SYSTEM
4. IN THE FLIGHT COMPARTMENT (FIG.2-A)
REMOVE ACCESS PANEL 211FZ (212FZ)

003

_______
REMOVAL
THIS REMOVAL/INSTALLATION PROCEDURE IS APPLICABLE TO THE FOLLOWING ITEMS:
---------ITEM--------------ZONE---ACCESS--FIN-1. RELAY-SIDE WINDOW
SUPPLY, L
2. RELAY-SIDE WINDOW
SUPPLY, R
3. RELAY-SIDE WINDOW
POWER, L
4. RELAY-SIDE WINDOW
POWER, R

POWER
POWER
MAIN
MAIN

210

211FZ

27DG

210

212FZ

28DG

210

211FZ

31DG

210

212FZ

30DG

*** CONTINUED ***


AH

24-00-00
RAI 10040-001
2-400 PAGE
2
APR 01/05

24-00-00

REMOVAL AND INSTALLATION


OF CONTACTORS AND RELAYS
IN FLIGHT COMPARTMENT

RAI 10040-001
3

APR05

REF.FIG.240000-RAI-00140
1. REMOVE CAPTIVE SCREWS(3) ATTACHING RELAY (1)
2. REMOVE RELAY FROM ITS BASE (2) TAKING CARE
NOT TO DAMAGE ELECTRICAL CONNECTOR
004

____________
INSTALLATION
REF.FIG.240000-RAI-00140
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA
2. CHECK FOR CORRECT CONDITION OF ELECTRICAL
CONNECTOR
3. INSTALL RELAY(1) ON ITS BASE(2) AND TIGHTEN
CAPTIVE SCREWS (3)

005

________
CLOSE
UP
REF.FIG.240000-RAI-00100 (FIG.1)
REF.FIG.240000-RAI-00140 (FIG.2)
1. IN THE FLIGHT COMPARTMENT (FIG.2-A)
INSTALL ACCESS PANEL 211FZ (212FZ)
2. REMOVE THE WARNING NOTICE FROM PANEL 29VU
(FIG.1-A)

006

________________
OPERATIONAL
TEST
SEE JOB INSTRUCTION CARD
304200-OPT-10000
*****

AH

E N D

O F

T E X T

*****

24-00-00
RAI 10040-001
2-400 PAGE
3
APR 01/05

24-00-00
4

AH

CONTROLS AND INDICATING

RAI 10040-001
APR05

24-00-00
RAI 10040-001

2-400

PAGE
4
APR 01/05

24-00-00
5

AH

RAI OF CONTACTORS AND


RELAYS IN FLIGHT COMPARTMENT

RAI 10040-001
APR05

24-00-00
RAI 10040-001

2-400

PAGE
5
APR 01/05

24-00-00

REMOVAL AND INSTALLATION


OF HALL EFFECT SENSORS
IN NACELLE

RAI 10060-001
1

MAR13

ZONING DATA
___________
ZONE
ACCESS

: 114
212
: 512
612

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

SPARE

: 01
01
01
01

AH

___
MEN

_________
MAN-HOURS
01

HALL EFFECT SENSOR-Z 512


PROTECTIVE CAP-Z 512
HALL EFFECT SENSOR-Z 612
PROTECTIVE CAP-Z 612

24-32-60
24-32-60
24-32-60
24-32-60

24-00-00
RAI 10060-001
2-400 PAGE
1
MAR 01/13

24-00-00

REMOVAL AND INSTALLATION


OF HALL EFFECT SENSORS
IN NACELLE

001

RAI 10060-001
2

MAR13

___________
PREPARATION
REF.FIG.240000-RAI-00100
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO THE DC EXTERNAL POWER RECEPTACLE (ON PANELS 5002VU AND 5000VU/F AND D)
AND THE ACCESS DOORS 114BR AND 114CR (E AND
C) ARE CLOSED
2. ON PANEL 29VU(A) MAKE CERTAIN THAT:
BAT SELECTOR SWITCH 7PA IS IN OFF POSITION
3. DISPLAY A WARNING NOTICE ON PANEL 29VU AND
26VU(B) PROHIBITING POWER SUPPLY TO SYSTEM
4. ON L(R) WING (SEE ON THE CORRESPONDING FIGURE OF EACH REM/INS):
REMOVE PANEL 512(612)

002

_____________________________
REMOVAL
OF HALL EFFECT SENSOR
REF.FIG.240000-RAI-00160 OR 240000-RAI-00161
1. PULL THE PROTECTIVE CAP (3) (IF APPLICABLE)
FROM THE ELECTRICAL CONNECTOR (2)
2. UNPLUG ELECTRICAL CONNECTOR (2)
3. PUT BLANKING CAP ON ELECTRICAL CONNECTOR
4. REMOVE SCREW (9) AND NUT (12), WASHER (8)
TO DISCONNECT TERMINAL LUG (7)
5. REMOVE SCREWS (4) AND WASHERS (5) SECURING
CLAMPS (6)
6. REMOVE THE WIRE WITH TERMINAL LUG FROM HALL
EFFECT SENSOR (1)
7. REMOVE CAPTIVE SCREWS (11) SECURING HALL EF*** CONTINUED ***
AH

24-00-00
RAI 10060-001
2-400 PAGE
2
MAR 01/13

24-00-00

REMOVAL AND INSTALLATION


OF HALL EFFECT SENSORS
IN NACELLE

RAI 10060-001
3

MAR13

FECT SENSOR
8. REMOVE HALL EFFECT SENSOR
003

__________________________________
INSTALLATION
OF HALL EFFECT SENSOR
REF.FIG.240000-RAI-00160 OR 240000-RAI-00161
01. CLEAN AND INSPECT COMPONENT INTERFACE AND/
OR COMPONENT ADJACENT AREA.
02. INSTALL HALL EFFECT SENSOR (1). TIGHTEN CAP
TIVE SCREWS (11)
03. INSERT THE WIRE WITH TERMINAL LUG THROUGH
SENSOR
04. INSTALL CLAMPS (6)
05. INSTALL WASHERS (5) AND SCREWS (4). TIGHTEN
SCREWS
06. CONNECT TERMINAL LUG (7)
07. INSTALL WASHER (8), SCREW (9) AND NUT (12).
TIGHTEN SCREW AND NUT TO A TORQUE VALUE
BETWEEN 2.6 TO 3 M.DAN
(19.17 TO 22.12 LBF.FT)
CAUTION: CONTACT SURFACE ON GROUNDING
FITTING AT LEVEL OF THE TERMINAL LUG (7)
ATTACHMENT MUST BE UNPROTECTED OVER
A DIAMETER OF 24MM (0.94 IN)
08. APPLY A COAT OF VARNISH (16-003B)
ON THE SCREW (9), ON THE NUT (12)
AND ON ALL GROUDING FITTING BARE
AREAS AT LEVEL OF THE TERMINAL LUG
(7) ATTACHMENT
09. REMOVE BLANKING CAP FROM ELECTRICAL CONNEC*** CONTINUED ***
AH

24-00-00
RAI 10060-001
2-400 PAGE
3
MAR 01/13

24-00-00

REMOVAL AND INSTALLATION


OF HALL EFFECT SENSORS
IN NACELLE

RAI 10060-001
4

MAR13

TOR (2)
10. PLUG IN ELECTRICAL CONNECTOR
11. COVER ELECTRICAL CONNECTOR WITH PROTECTIVE
CAP (3) (IF APPLICABLE)
NOTE: MARK SCREW (9) WITH RED VARNISH
004

________
CLOSE
UP
REF.FIG.240000-RAI-00100
1. ON L(R) WING (SEE ON THE CORRESPONDING FIGURE OF EACH REM/INS)
CLOSE PANEL 512(612)
2. REMOVE THE WARNING NOTICE FROM PANEL 29VU
AND 26VU(A AND B)

005

________________
OPERATIONAL
TEST
THIS TEXT IS NOT APPLICABLE
*****

AH

E N D

O F

T E X T

*****

24-00-00
RAI 10060-001
2-400 PAGE
4
MAR 01/13

24-00-00
5

AH

CONTROLS AND INDICATING

RAI 10060-001
MAR13

24-00-00
RAI 10060-001

2-400

PAGE
5
MAR 01/13

24-00-00
6

AH

REM/INS OF HALL EFFECT


SENSOR

RAI 10060-001
MAR13

24-00-00
RAI 10060-001

2-400

PAGE
6
MAR 01/13

24-00-00
7

AH

REM/INS OF HALL EFFECT


SENSOR

RAI 10060-001
MAR13

24-00-00
RAI 10060-001

2-400

PAGE
7
MAR 01/13

24-21-00

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

OPT 10000-001
1

DEC14

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

24-46-00-EAD-10000

24-21-00
OPT 10000-001
2-400 PAGE
1
DEC 01/14

24-21-00

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

001

OPT 10000-001
2

DEC14

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

002

AC CONSTANT FREQUENCY GENERATION OPERATIONAL


____________________________________________
TEST
____
REF. FIG. 242100-OPT-00100
01. ON PANEL 127VU (A)
OPEN, SAFETY AND TAG THE FOLLOWING
CIRCUIT BREAKER:
3XA PWR SUPPLY ON PRIM DC BUS 1/INV 1
A. VERIFY THAT THE CREW ALERTING SYSTEM
IS ACTIVATED IN THE FOLLOWING WAY:
1. SINGLE CHIME SOUNDS
2. CAPT AND F/O MASTER CAUTION LIGHTS
(B) COME ON
3. ON PANEL 175WW (C)
ELEC CAUTION LIGHT COMES ON
4. ON PANEL 29VU (D)
BUS OFF 1 LEGEND OF CAUTION LIGHT
COMES ON
B. CHECK THAT, DURING THE FIRST 15 SEC, AT
LEAST ONE OF THESE INSTRUMENTS DOES NOT
WORK:
- FLAPS IND
- CTL SURFACES POSITIONS SYNCHRO
DETECTOR
- PITOT STBY
- DFDR
- INFORMATION: VOR1 & ADF1 ON RMI &
SGU1 & 2 HEADING ON RMI2
- ATTITUDE & HEADING INFORMATION ON FDAU
- COURSE 1 & HEADING
C. 10 SEC AFTER C/B OPENING, CHECK THAT:
*** CONTINUED ***
AH

24-21-00
OPT 10000-001
2-400 PAGE
2
DEC 01/14

24-21-00

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

OPT 10000-001
3

DEC14

- ON PANEL 175WW
ELEC CAUTION LIGHT REMAINS ON
- ON PANEL 29VU
.BUS OFF 1 LEGEND GOES OFF
.INV FAULT 1 LEGEND OF CAUTION LIGHT
COMES ON
D. 15 SEC AFTER C/B OPENING,
- CHECK THAT CAPT AND F/O MASTER CAUTION
LIGHTS GO OFF
- VERIFY THAT ONE AT LEAST OF THESE
INSTRUMENTS WORKS (ALL SUPPLIED
BY 26 AND 115VAC STBY BUSES):
- FLAPS IND
- CTL SURFACES POSITIONS SYNCHRO
DETECTOR
- PITOT STBY
- DFDR
- INFORMATION: VOR1 & ADF1 ON RMI &
SGU 1 & 2 HEADING ON RMI2
- ATTITUDE & HEADING INFORMATION ON
FDAU
- COURSE1 & HEADING
02. 0N PANEL 127VU
REMOVE SAFETY CLIP AND TAG AND CLOSE THE
FOLLOWING CIRCUIT BREAKER:
3XA
A. ON PANEL 175WW VERIFY THAT:
ELEC CAUTION LIGHT GOES OFF
B. ON PANEL 29VU VERIFY THAT:
INV FAULT 1 LEGEND OF CAUTION LIGHT
GOES OFF
03. ON PANEL 124VU (A)
OPEN, SAFETY AND TAG THE FOLLOWING
CIRCUIT BREAKER:
10XA PWR SUPPLY ON PRIM DC BUS 2/INV 2
*** CONTINUED ***
AH

24-21-00
OPT 10000-001
2-400 PAGE
3
DEC 01/14

24-21-00

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

OPT 10000-001
4

DEC14

A. VERIFY THAT THE CREW ALERTING SYSTEM


IS ACTIVATED IN THE FOLLOWING WAY:
1. SINGLE CHIME SOUNDS
2. CAPT AND F/O MASTER CAUTION LIGHTS
(B) COME ON
3. ON PANEL 175WW (C)
ELEC CAUTION LIGHT COMES ON
4. ON PANEL 29VU (D)
BUS OFF 2 LEGEND OF CAUTION LIGHT
COMES ON
B. AFTER 10 SEC VERIFY THAT:
- CAPT AND F/O MASTER CAUTION LIGHTS
GO OFF
- ON PANEL 175WW
ELEC CAUTION LIGHT REMAINS ON
- ON PANEL 29VU
.BUS OFF 2 LEGEND GOES OFF
.INV FAULT 2 LEGEND COMES ON
04. ON PANEL 124VU
REMOVE SAFETY CLIP AND TAG AND CLOSE THE
FOLLOWING CIRCUIT BREAKER:
10XA
A. ON PANEL 29VU VERIFY THAT:
INV FAULT 2 LEGEND OF CAUTION LIGHT
GOES OFF
B. ON PANEL 175WW VERIFY THAT:
ELEC CAUTION LIGHT GOES OFF
003

__________________________________________
INV1
MAIN BUSES CTL RELAY OPERATIONAL TEST
REF.FIG.242100-OPT-00100 (FIG.1)
REF.FIG.314800-PRO-00100 (FIG.2)
01. ON PANEL 25VU (FIG.2-A)
RELEASE THE FOLLOWING PUSHBUTTON SWITCHES:
*** CONTINUED ***
AH

24-21-00
OPT 10000-001
2-400 PAGE
4
DEC 01/14

24-21-00

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

OPT 10000-001
5

DEC14

6UA2 MFC/2B
7UA2 MFC/2A
(BOTH OFF LEGENDS COME ON)
NOTE: DO NOT TAKE INTO ACCOUNT VARIOUS ALERTS
FOLLOWING SWITCHING OF PUSHBUTTON
SWITCHES 6UA2 AND 7UA2 (STEPS 01 AND 11)
02. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
A - SINGLE CHIME SOUNDS
B - CAPT AND F/O MASTER CAUTION LIGHTS 13WW
AND 168WW COME ON
C - ON PANEL 175WW (FIG.1-C)
MFC CAUTION LIGHT COMES ON
D - THE VENTILATION TO L AND R ELECTRONICS
RACKS 80VU AND 90VU IS OFF
03. PUSH ON CAUTION LIGHT 13WW OR 168WW TO RESET EITHER THESE ONES OR SINGLE CHIME
04. ON PANEL 122VU (FIG.1-A)
OPEN SAFETY CLIP AND TAG THE FOLLOWING
CIRCUIT BREAKER:
39XA MAIN ELEC PWR/AC/INV1 CAUTION BUS1
& TIE RLY SPLY
05. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
A - SINGLE CHIME SOUNDS
B - CAUTION LIGHTS 13WW AND 168WW COME ON
C - ON PANEL 175WW
ELEC CAUTION LIGHT COMES ON
06. ON PANEL 29VU (FIG.1-D) VERIFY THAT
BUS OFF 1/2 LEGENDS OF CAUTION LIGHT 7XN
AND 8XN COME ON
07. PUSH ON CAUTION LIGHT 13WW OR 168WW TO RESET EITHER THESE ONES OR SINGLE CHIME
*** CONTINUED ***
AH

24-21-00
OPT 10000-001
2-400 PAGE
5
DEC 01/14

24-21-00

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

OPT 10000-001
6

DEC14

08. ON PANEL 122VU


REMOVE SAFETY CLIP AND TAG AND CLOSE THE
FOLLOWING CIRCUIT BREAKER:
39XA
09. ON PANEL 29VU VERIFY THAT:
BUS OFF 1/2 LEGENDS OF CAUTION LIGHT 7XN
AND 8XN GO OFF
10. ON PANEL 175WW VERIFY THAT:
ELEC CAUTION LIGHT GOES OFF
11. ON PANEL 25VU
PRESS THE FOLLOWING PUSHBUTTON SWITCHES:
6UA2
7UA2
(BOTH OFF LEGENDS GO OFF)
12. ON PANEL 175WW VERIFY THAT:
MFC CAUTION LIGHT GOES OFF
NOTE: THE VENTILATION TO ELECTRONICS RACKS IS
ACTIVATED AFTER ABOUT 120 SECS.
004

__________________________________________
INV2
MAIN BUSES CTL RELAY OPERATIONAL TEST
REF. FIG. 242100-OPT-00100 (FIG.1)
REF. FIG. 314800-PRO-00100 (FIG.2)
01. ON PANEL 25VU (FIG.2-A)
RELEASE THE FOLLOWING PUSHBUTTON SWITCHES:
6UA1 MFC/1B
7UA1 MFC/1A
(BOTH OFF LEGENDS COME ON)
NOTE: DO NOT TAKE INTO ACCOUNT VARIOUS ALERTS
FOLLOWING SWITCHING OF PUSHBUTTON
SWITCHES 6UA2 AND 7UA2 (STEPS 01 AND 09)
02. VERIFY THAT THE CREW ALERTING SYSTEM IS ACTIVATED IN THE FOLLOWING WAY:
*** CONTINUED ***
AH

24-21-00
OPT 10000-001
2-400 PAGE
6
DEC 01/14

24-21-00

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

OPT 10000-001
7

DEC14

A - SINGLE CHIME SOUNDS


B - CAPT AND F/O MASTER CAUTION LIGHTS 13WW
AND 168WW COME ON
C - ON PANEL 175WW (FIG.1-C)
ELEC AND MFC CAUTION LIGHTS COME ON
03. ON PANEL 29VU (FIG.1-D) VERIFY THAT:
BUS OFF 1 LEGEND OF CAUTION LIGHT 7XN COMES ON
04. PUSH ON CAUTION LIGHTS 13WW OR 168WW TO
RESET EITHER THESE ONES OR SINGLE CHIME
05. ON PANEL 122VU (FIG.1-A)
OPEN SAFETY CLIPS AND TAGS THE FOLLOWING
CIRCUIT BREAKER:
6XA MAIN ELEC PWR/AC/INV 2 CAUTION & BUS 2
RLY SPLY
06. ON PANEL 29VU VERIFY THAT:
BUS OFF 2 LEGEND OF CAUTION LIGHT 8XN COMES ON
07. ON PANEL 122VU
REMOVE SAFETY CLIP AND TAG AND CLOSE THE
FOLLOWING CIRCUIT BREAKERS:
6XA
08. ON PANEL 29VU VERIFY THAT:
BUS OFF 2 LEGEND OF CAUTION LIGHT 8XN GOES
OFF
09. ON PANEL 25VU
PRESS THE FOLLOWING PUSHBUTTON SWITCHES:
6UA1
7UA1
(BOTH OFF LEGENDS GO OFF)
10. ON PANEL 175WW VERIFY THAT:
MFC CAUTION LIGHT GOES OFF
ELEC CAUTION LIGHT REMAINS ON
*** CONTINUED ***
AH

24-21-00
OPT 10000-001
2-400 PAGE
7
DEC 01/14

24-21-00

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

OPT 10000-001
8

DEC14

11. ON PANEL 29VU VERIFY THAT:


BUS OFF 1 LEGEND OF CAUTION LIGHT 7XN GOES
OFF
005

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-21-00
OPT 10000-001
2-400 PAGE
8
DEC 01/14

24-21-00
9

AH

CONTROLS AND INDICATING

OPT 10000-001
DEC14

24-21-00
OPT 10000-001

2-400

PAGE
9
DEC 01/14

24-21-00

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

OPT 10000-002
1

DEC14

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC
JIC

: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY
: PRINCIPLE OF CDS USE
(DISPLAY UNITS
EXPLORATION)

AH

24-46-00-EAD-10000
31-63-00-PRO-10000

24-21-00
OPT 10000-002
2-400 PAGE
1
DEC 01/14

24-21-00

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

001

OPT 10000-002
2

DEC14

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

002

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

003

AC CONSTANT FREQUENCY GENERATION OPERATIONAL


____________________________________________
TEST
____
REF. FIG. 242100-OPT-00100
1. - ON LH EFCP, PRESS CLR PUSH BUTTON
- ON MFD, SELECT ELEC SD PAGE
2. ON PANEL 127VU
OPEN, SAFETY AND TAG THE FOLLOWING CIRCUIT
BREAKER:
- 3XA PWR SUPPLY ON PRIM DC BUS 1/INV 1
A. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
- SINGLE CHIME SOUNDS
- MASTER CAUTION LIGHTS COME ON
- ON EWD, IN ALERT WINDOW, ELEC AC BUS
1 MESSAGE AND AC BUS 1 OFF
ASSOCIATED PROCEDURES ARE DISPLAYED.
(DO NOT PAY ATTENTION TO OTHER
*** CONTINUED ***
AH

24-21-00
OPT 10000-002
2-400 PAGE
2
DEC 01/14

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

24-21-00

OPT 10000-002
3

DEC14

MESSAGES).
- ON PANEL 29VU
BUS OFF FOR AC BUS 1 CAUTION LIGHT
COMES ON
- ON MFD UPPER WINDOW, IN ELEC SD PAGE
AMBER AC BUS 1 OFF SYMBOL
IS DISPLAYED
B. CHECK THAT, DURING THE FIRST 15 SEC,
ON MFD UPPER WINDOW, IN ELEC SD PAGE:
- AMBER AC STBY BUS SYMBOL IS DISPLAYED
C. 10 SEC AFTER C/B OPENING, CHECK THAT:
- MASTER CAUTION LIGHTS GO OFF
- ON EWD, IN ALERT WINDOW, ELEC INV 1
MESSAGE AND INV FAULT ASSOCIATED
PROCEDURES ARE DISPLAYED (DO NOT PAY
ATTENTION TO OTHER MESSAGES)
- ON PANEL 29VU
. BUS OFF FOR AC BUS 1 CAUTION LIGHT
GOES OFF
. INV FAULT FOR INV 1 CAUTION LIGHT
COMES ON
- ON MFD UPPER WINDOW, IN ELEC SD PAGE:
GREEN AC BUS 1 SYMBOL AND
AMBER INV 1 FAULT SYMBOL ARE
DISPLAYED
D. 15 SEC AFTER C/B OPENING,
ON MFD UPPER WINDOW, IN ELEC SD PAGE:
GREEN AC STBY BUS SYMBOL IS DISPLAYED
3. ON PANEL 127VU
REMOVE SAFETY CLIP AND TAG AND CLOSE THE
FOLLOWING CIRCUIT BREAKER:
3XA
A. ON EWD, IN ALERT WINDOW,
- ELEC INV1 MESSAGE AND INV FAULT
ASSOCIATED PROCEDURES ARE NO LONGER
DISPLAYED
- MASTER CAUTION LIGHTS GO OFF
*** CONTINUED ***
AH

24-21-00
OPT 10000-002
2-400 PAGE
3
DEC 01/14

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

24-21-00

OPT 10000-002
4

DEC14

B. VERIFY THAT
- ON PANEL 29VU:
INV FAULT FOR INV1 CAUTION LIGHT
GOES OFF
- ON MFD UPPER WINDOW, IN ELEC SD PAGE:
GREEN INV 1 SYMBOL IS DISPLAYED
4. ON PANEL 124VU
OPEN, SAFETY AND TAG THE FOLLOWING CIRCUIT
BREAKER:
- 10XA PWR SUPPLY ON PRIM DC BUS 2/INV 2
A. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
- SINGLE CHIME SOUNDS
- MASTER CAUTION LIGHTS COME ON
- ON EWD, IN ALERT WINDOW, ELEC AC BUS
2 MESSAGE AND AC BUS 2 OFF
ASSOCIATED PROCEDURES ARE DISPLAYED.
(DO NOT PAY ATTENTION TO OTHER
MESSAGES)
- ON PANEL 29VU
BUS OFF FOR AC BUS 2 CAUTION LIGHT
COMES ON
- ON MFD UPPER WINDOW, IN ELEC SD PAGE
AMBER AC BUS 2 OFF SYMBOL
IS DISPLAYED
B. AFTER 10 SEC VERIFY THAT:
- MASTER CAUTION LIGHTS GO OFF
- ON EWD, IN ALERT WINDOW, ELEC INV 2
MESSAGE AND INV FAULT ASSOCIATED
PROCEDURES ARE DISPLAYED (DO NOT PAY
ATTENTION TO OTHER MESSAGES)
- ON PANEL 29VU
- BUS OFF FOR AC BUS 2 CAUTION LIGHT
GOES OFF
- INV FAULT FOR INV 2 CAUTION LIGHT
GOES ON
- ON MFD UPPER WINDOW, IN ELEC SD PAGE
GREEN AC BUS 2 SYMBOL AND
*** CONTINUED ***
AH

24-21-00
OPT 10000-002
2-400 PAGE
4
DEC 01/14

24-21-00

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

OPT 10000-002
5

DEC14

AMBER INV 2 FAULT SYMBOL ARE


DISPLAYED
5. ON PANEL 124VU
REMOVE SAFETY CLIP AND TAG AND CLOSE THE
FOLLOWING CIRCUIT BREAKER:
- 10XA
A. VERIFY:
- ON PANEL 29VU, INV FAULT FOR INV 2
CAUTION LIGHT GOES OFF
- ON MFD UPPER WINDOW, IN ELEC SD PAGE:
GREEN INV 2 SYMBOL IS DISPLAYED
B. ON EWD, IN ALERT WINDOW, ELEC INV 2
MESSAGE AND INV FAULT ASSOCIATED
PROCEDURES ARE NO LONGER DISPLAYED
004

__________________________________________
INV1
MAIN BUSES CTL RELAY OPERATIONAL TEST
REF. FIG. 242100-OPT-00100
REF. FIG. 314800-PRO-00100
1. ON LH EFCP, PRESS CLR PUSH BUTTON
2. ON PANEL 25VU
RELEASE THE FOLLOWING PUSHBUTTON SWITCHES:
6UA2 MFC/2B
7UA2 MFC/2A
(BOTH OFF LEGENDS COME ON)
NOTE: DO NOT TAKE INTO ACCOUNT VARIOUS ALERTS
FOLLOWING SWITCHING OF PUSHBUTTON
SWITCHES 6UA2 AND 7UA2 (STEPS 02 AND 12)
3. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
- SINGLE CHIME SOUNDS
- MASTER CAUTION LIGHTS COME ON
- ON EWD, IN ALERT WINDOW, MFC 2A + 2B
MESSAGE IS DISPLAYED (DO NOT PAY
ATTENTION TO OTHER MESSAGES)
*** CONTINUED ***
AH

24-21-00
OPT 10000-002
2-400 PAGE
5
DEC 01/14

24-21-00

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

OPT 10000-002
6

DEC14

- THE VENTILATION TO L AND R ELECTRONICS


RACKS 80VU AND 90VU IS OFF
4. PUSH MASTER CAUTION LIGHT TO RESET
EITHER THESE ALERTS OR SINGLE CHIME
5. ON PANEL 122VU
OPEN, SAFETY AND TAG THE FOLLOWING
CIRCUIT BREAKER:
- 39XA MAIN ELEC PWR/AC/INV1 CAUTION BUS1
& TIE RLY SPLY
6. ON PANEL 120VU
OPEN, SAFETY AND TAG THE FOLLOWING CIRCUIT
BREAKERS:
- 3XD MAIN ELEC PWR_AC/AC STBY BUS SUPPLY/
26 VAC
- 4XD MAIN ELEC PWR_AC/AC STBY BUS SUPPLY/
115VAC
7. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
- SINGLE CHIME SOUNDS
- CAUTION LIGHTS COME ON
- ON EWD, IN ALERT WINDOW,(DO NOT PAY
ATTENTION TO OTHER MESSAGES):
. ELEC AC BUS 1 MESSAGE AND AC BUS 1
OFF ASSOCIATED PROCEDURES ARE
DISPLAYED
. ELEC AC BUS 2 MESSAGE AND AC BUS 2
OFF ASSOCIATED PROCEDURES ARE
DISPLAYED
8. VERIFY:
- ON PANEL 29VU
BUS OFF 1/2 CAUTION LIGHTS COME ON
- ON MFD UPPER WINDOW, IN SD ELEC PAGE:
. AMBER AC BUS 1 OFF SYMBOL AND
. AMBER AC BUS 2 OFF SYMBOL ARE
DISPLAYED
. AMBER AC STBY BUS SYMBOL IS DISPLAYED
*** CONTINUED ***
AH

24-21-00
OPT 10000-002
2-400 PAGE
6
DEC 01/14

24-21-00

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

OPT 10000-002
7

DEC14

9. PUSH MASTER CAUTION LIGHT TO RESET


EITHER THESE ALERTS OR SINGLE CHIME
10. ON PANEL 120VU AND 122VU
CLOSE THE FOLLOWING CIRCUIT BREAKERS:
FOLLOWING CIRCUIT BREAKER:
- 39XA MAIN ELEC PWR/AC/INV1 CAUTION BUS1
& TIE RLY SPLY
- 3XD MAIN ELEC PWR_AC/AC STBY BUS SUPPLY
/26 VAC
- 4XD MAIN ELEC PWR_AC/AC STBY BUS SUPPLY
/115VAC
11. VERIFY:
- ON PANEL 29VU
BUS OFF FOR AC BUS 1 AND 2 CAUTION
LIGHTS GO OFF
- ON MFD UPPER WINDOW, IN SD ELEC PAGE
. GREEN AC BUS 1 SYMBOL,
. GREEN AC BUS 2 SYMBOL, AND
. GREEN AC STBY BUS SYMBOL ARE
DISPLAYED
12. ON EWD, IN ALERT WINDOW,
- ELEC AC BUS 1 MESSAGE AND AC BUS 1
OFF ASSOCIATED PROCEDURES ARE NO LONGER
DISPLAYED
- ELEC AC BUS 2 MESSAGE AND AC BUS 2
OFF ASSOCIATED PROCEDURES ARE NO LONGER
DISPLAYED
- ELEC AC STBY MESSAGE AND AC STBY BUS
FAULT ASSOCIATED PROCEDURES ARE NO
LONGER DISPLAYED
13. ON PANEL 25VU
PRESS THE FOLLOWING PUSHBUTTON SWITCHES:
6UA2 MFC/2B
7UA2 MFC/2A
(BOTH OFF LEGENDS GO OFF)
14. ON EWD, IN ALERT WINDOW,
*** CONTINUED ***
AH

24-21-00
OPT 10000-002
2-400 PAGE
7
DEC 01/14

24-21-00

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

OPT 10000-002
8

DEC14

MFC 2A + 2B MESSAGE NO LONGER DISPLAYED


NOTE: THE VENTILATION TO ELECTRONICS RACKS IS
ACTIVATED AFTER ABOUT 120 SECS.
005

__________________________________________
INV2
MAIN BUSES CTL RELAY OPERATIONAL TEST
REF. FIG. 242100-OPT-00100
REF. FIG. 314800-PRO-00100
1. ON LH EFCP, PRESS CLR PUSH BUTTON
2. ON PANEL 25VU
RELEASE THE FOLLOWING PUSHBUTTON SWITCHES:
6UA1 MFC/1B
7UA1 MFC/1A
(BOTH OFF LEGENDS COME ON)
NOTE: DO NOT TAKE INTO ACCOUNT VARIOUS ALERTS
FOLLOWING SWITCHING OF PUSHBUTTON
SWITCHES 6UA2 AND 7UA2 (STEPS 2 AND 10)
3. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
A - SINGLE CHIME SOUNDS
B - MASTER CAUTION LIGHTS COME ON
C - ON EWD, IN ALERT WINDOW,(DO NOT PAY
ATTENTION TO OTHER MESSAGES)
MFC 1A + 1B MESSAGE IS DISPLAYED
ELEC AC BUS 1 MESSAGE AND AC BUS 1
OFF ASSOCIATED PROCEDURES ARE DISPLAYED
4. VERIFY:
- ON PANEL 29VU
BUS OFF FOR AC BUS 1 CAUTION LIGHT
COMES ON
- ON MFD UPPER WINDOW, IN ELEC SD PAGE
AMBER AC BUS 1 OFF SYMBOL IS DISPLAYED
5. PUSH MASTER CAUTION LIGHTS TO RESET
EITHER THESE ALERTS OR SINGLE CHIME
*** CONTINUED ***
AH

24-21-00
OPT 10000-002
2-400 PAGE
8
DEC 01/14

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

24-21-00

OPT 10000-002
9

DEC14

6. ON PANEL 120 & 122VU


OPEN, SAFETY AND TAGS THE FOLLOWING
CIRCUIT BREAKERS:
- 6XA MAIN ELEC PWR/AC/INV 2 CAUTION & BUS 2
RLY SPLY
- 3XD MAIN ELEC PWR AC/AC STBY BUS SUPPLY/
26 VAC
- 4XD MAIN ELEC PWR AC/AC STBY BUS SUPPLY/
115VAC
7. VERIFY
- ON PANEL 29VU
BUS OFF FOR AC BUS 2 CAUTION LIGHT
COMES ON
- ON MFD UPPER WINDOW, IN ELEC SD PAGE
AMBER AC BUS 2 SYMBOL AND AMBER AC STBY
BUS ARE DISPLAYED
8. ON PANEL 120 & 122VU
REMOVE SAFETY CLIP AND TAG AND CLOSE THE
FOLLOWING CIRCUIT BREAKERS:
- 6XA MAIN ELEC PWR/AC/INV 2 CAUTION & BUS 2
RLY SPLY
- 3XD MAIN ELEC PWR AC/AC STBY BUS SUPPLY/
26 VAC
- 4XD MAIN ELEC PWR AC/AC STBY BUS SUPPLY/
115VAC
9. VERIFY:
- ON PANEL 29VU
BUS OFF FOR AC BUS 2 CAUTION LIGHT
GOES OFF
- ON MFD UPPER WINDOW, IN ELEC SD PAGE
GREEN AC BUS 2 AND GREEN AC STBY BUS
SYMBOLS ARE DISPLAYED
- ON EWD, IN ALERT WINDOW, ELEC AC BUS 2
MESSAGE AND AC BUS 2 OFF ASSOCIATED
PROCEDURES ARE NO LONGER DISPLAYED.
- AC STBY BUS FAULT ASSOCIATED PROCEDURES
ARE NO LONGER DISPLAYED.
*** CONTINUED ***
AH

24-21-00
OPT 10000-002
2-400 PAGE
9
DEC 01/14

24-21-00

AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

OPT 10000-002
10

DEC14

10. ON PANEL 25VU


PRESS THE FOLLOWING PUSHBUTTON SWITCHES:
6UA1 MFC/1B
7UA1 MFC/1A
(BOTH OFF LEGENDS GO OFF)
11. ON EWD, IN ALERT WINDOW,
MFC 1A + 1B MESSAGE NO LONGER DISPLAYED
12. VERIFY:
- ON PANEL 29VU
BUS OFF FOR AC BUS 1 CAUTION LIGHT
GOES OFF
- ON MFD UPPER WINDOW, IN ELEC SD PAGE
GREEN AC BUS 1 SYMBOL IS DISPLAYED
006

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-21-00
OPT 10000-002
2-400 PAGE
10
DEC 01/14

24-21-00
11

AH

CONTROLS AND INDICATING

OPT 10000-002
DEC14

24-21-00
OPT 10000-002

2-400

PAGE
11
DEC 01/14

24-21-81

STATIC INVERTER REMOVAL


AND INSTALLATION

RAI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 210
214
: 214BZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC
MECHANIC

___
MEN

_________
MAN-HOURS
01
01

ELAPSED TIME

SPARE

: 02 STATIC INVERTER:1XA-2XA

24-21-80-02-010

: AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST

24-21-00-OPT-10000

PUBLICATION
___________
JIC

AH

24-21-81
RAI 10000-001
2-400 PAGE
1
APR 01/05

24-21-81

STATIC INVERTER REMOVAL


AND INSTALLATION

001

RAI 10000-001
2

APR05

___________
PREPARATION
REF.FIG.240000-RAI-00103
1. OPEN THE FOLLOWING CIRCUIT BREAKERS:
- ON PANEL 122VU
5XA MAIN ELEC PWR-AC/BUS 1 RLY CTL
6XA MAIN ELEC PWR-AC/INV 2 CAUTION & BUS
2 RLY SPLY
36XA MAIN ELEC PWR-AC/BUS 2 & STBY BUS RLY
CTL
39XA MAIN ELEC PWR-AC/INV 1 CAUTION BUS 1
& TIE RLY SPLY
- ON PANEL 124VU
10XA PWR SUPPLY ON PRIM DC BUS 2/INV 2
- ON PANEL 127VU
3XA PWR SUPPLY ON PRIM DC BUS 1/INV 1
- ON PANEL 129VU
4XA INV 1 HOT MAIN BAT BUS
- ON PANEL 130VU
7XA INV 1 ON HOT EMER BAT BUS
2. ON R ELECTRONICS RACK 90VU
REMOVE ACCESS DOOR 214BZ

002

__________________________
REMOVAL
OF STATIC INVERTER
REF.FIG.242111-RAI-00110
1. UNPLUG ELECTRICAL CONNECTOR (9)
2. PUT BLANKING CAP ON ELECTRICAL CONNECTOR
3. LOOSEN KNURLED FASTENER (7) RETAINING PROTECTIVE COVER (8)
4. REMOVE COVER
5. REMOVE NUTS (6) SECURING TERMINAL LUGS (5)
OF ELECTRICAL POWER SUPPLY AND DISTRIBUTION
*** CONTINUED ***
AH

24-21-81
RAI 10000-001
2-400 PAGE
2
APR 01/05

24-21-81

STATIC INVERTER REMOVAL


AND INSTALLATION

RAI 10000-001
3

APR05

6. REMOVE NUT (4) SECURING BONDING STRIP (3)


7. REMOVE BONDING STRIP
8. UNSCREWS CAPTIVE SCREWS (2) RETAINING STATIC
INVERTER (1)
9. REMOVE STATIC INVERTER
003

_______________________________
INSTALLATION
OF STATIC INVERTER
REF.FIG.242111-RAI-00110
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA
2. POSITION STATIC INVERTER (1) IN RACK 90VU(A)
ON SHELF 93VU(B) OR 94VU(C)
3. INSTALL CAPTIVE SCREWS (2) TO SECURE STATIC
INVERTER TO SHELF. TIGHTEN SCREWS
4. INSTALL BONDING STRIP (3) AND NUT (4).
TIGHTEN NUT
5. INSTALL TERMINAL LUGS (5) FOR THE ELECTRICAL
POWER SUPPLY AND DISTRIBUTION AND NUTS (6).
TIGHTEN NUTS
NOTE: THE APPLICABLE TORQUE VALUE FOR THE
POSITIVE TERMINAL IS BETWEEN 0.45 AND
0.52 MDAN (40 TO 46 LBF.IN), FOR THE
NEGATIVE TERMINAL IS BETWEEN 0.25 AND
0.27 MDAN (22 TO 24 LBF.IN)
6. INSTALL PROTECTIVE COVER (8)
7. INSTALL KNURLED FASTENER (7) AND TIGHTEN
8. REMOVE BLANKING CAP FROM ELECTRICAL CON_
NECTOR (9)
*** CONTINUED ***
AH

24-21-81
RAI 10000-001
2-400 PAGE
3
APR 01/05

24-21-81

STATIC INVERTER REMOVAL


AND INSTALLATION

RAI 10000-001
4

APR05

9. PLUG IN ELECTRICAL CONNECTOR


004

________
CLOSE
UP
REF.FIG.240000-RAI-00103
1. ON R ELECTRONICS RACK 90VU
CLOSE ACCESS DOOR 214BZ
2. REMOVE SAFETY CLIPS AND TAGS AND CLOSE THE
FOLLOWING CIRCUIT BREAKERS:
- ON PANEL 122VU
5XA
6XA
36XA
39XA
- 0N PANEL 124VU
10XA
- ON PANEL 127VU
3XA
- ON PANEL 129VU
4XA
- ON PANEL 130VU
7XA

005

AC CONSTANT FREQUENCY GENERATION OPERATIONAL


____________________________________________
TEST
____
SEE JOB INSTRUCTION CARD
242100-OPT-10000
*****

AH

E N D

O F

T E X T

*****

24-21-81
RAI 10000-001
2-400 PAGE
4
APR 01/05

24-21-81
5

AH

ACCESS DOORS, C/B PANELS


& SHELVES (90VU - 120VU)

RAI 10000-001
APR05

24-21-81
RAI 10000-001

2-400

PAGE
5
APR 01/05

24-21-81
6

AH

RAI OF STATIC INVERTER

RAI 10000-001
APR05

24-21-81
RAI 10000-001

2-400

PAGE
6
APR 01/05

24-21-85

REMOVAL AND INSTALLATION


OF AC STBY BUSES
TRANSFER RELAY

RAI 10000-001
1

MAR15

ZONING DATA
___________
ZONE
ACCESS

: 212
220
: 212TZ 212VZ 214BZ 214PZ 222CZ 222QZ 222RZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

SPARE

: 01 RELAY:33XA

AH

___
MEN

_________
MAN-HOURS
01

24-21-80-02-130

24-21-85
RAI 10000-001
2-400 PAGE
1
MAR 01/15

24-21-85

REMOVAL AND INSTALLATION


OF AC STBY BUSES
TRANSFER RELAY

001

RAI 10000-001
2

MAR15

___________
PREPARATION
REF. FIG. 240000-RAI-00100 (FIG.1)
REF. FIG. 240000-RAI-00103 (FIG.2)
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO THE DC AND AC EXTERNAL POWER RECEPTACLES (ON PANELS 5002VU AND 5000VU
-FIG.1-F AND D) AND THE ACCESS DOORS 114BR
AND 114CR (FIG.1-E AND C) ARE CLOSED
2. ON PANEL 29VU (FIG.1-A) MAKE CERTAIN THAT:
BAT SELECTOR SWITCH 7PA IS IN OFF POSITION
3. DISPLAY A WARNING NOTICE ON PANELS 29VU AND
26VU (FIG.1-B) PROHIBITING POWER SUPPLY TO
SYSTEM
4. ON DC/AC POWER CENTER 120VU OR ON ELECTRONICS RACK 90VU (FIG.2 A AND B AND THE CORRESPONDING FIGURE OF EACH RAI)
120VU: REMOVE ACCESS PANEL 212TZ OR 212VZ
(123VU) OR CIRCUIT BREAKER PANEL 121V
U OR 122VU OR 124VU OR 125VU OR 126VU
OR 127VU OR 128VU OR 129VU OR 130VU
90VU - SIDE SHELF: REMOVE ACCESS PANEL 222RZ
(SHELF 91VU) OR 222QZ (SHELF 91VU OR
92VU OR 93VU) OR 222PZ (SHELF 94VU OR
95VU)
- FRONT SHELF: REMOVE ACCESS PANEL 214
CZ(SHELF 91VU OR 92VU) OR 214BZ(SHELF
93VU OR 94VU OR 95VU)

002

_____________________
REMOVAL
OF RELAY 33XA
REF.FIG.242185-RAI-00100
1. REMOVE SCREWS(1) RETAINING THE COVER(2)
2. REMOVE THE COVER
*** CONTINUED ***
AH

24-21-85
RAI 10000-001
2-400 PAGE
2
MAR 01/15

24-21-85

REMOVAL AND INSTALLATION


OF AC STBY BUSES
TRANSFER RELAY

RAI 10000-001
3

MAR15

3. REMOVE NUTS(8) AND WASHERS(7) TO DISCONNECT


TERMINAL LUGS(6)
4. MARK AND DISCONNECT THE TERMINAL LUGS
5. REMOVE SCREWS(5) AND WASHERS(4) RETAINING
RELAY(3)
6. REMOVE RELAY
003

__________________________
INSTALLATION
OF RELAY 33XA
REF.FIG.242185-RAI-00100
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA
2. INSTALL RELAY(3)
3. INSTALL WASHERS(4) AND SCREWS(5). TIGHTEN
SCREWS
4. INSTALL TERMINAL LUGS(6), WASHERS(7) AND
NUTS(8). TIGHTEN NUTS
5. INSTALL COVER(2)
6. INSTALL SCREWS(1). TIGHTEN SCREWS

004

________
CLOSE
UP
REF. FIG. 240000-RAI-00100 (FIG.1)
REF. FIG. 240000-RAI-00103 (FIG.2)
1. ON DC/AC POWER CENTER 12OVU OR ON ELECTRONICS RACK 90VU (FIG.2 A OR B AND THE CORRESPONDING FIGURE OF EACH RAI)
120VU: CLOSE ACCESS PANEL 212TZ OR 212VZ OR
CIRCUIT BREAKER PANEL 121VU OR 122VU
OR 124VU OR 125VU OR 127VU OR 128VU
OR 129VU OR 130VU
*** CONTINUED ***
AH

24-21-85
RAI 10000-001
2-400 PAGE
3
MAR 01/15

24-21-85

REMOVAL AND INSTALLATION


OF AC STBY BUSES
TRANSFER RELAY

RAI 10000-001
4

MAR15

90VU - SIDE SHELF: CLOSE ACCESS PANEL 222RZ


OR 222QZ OR 222PZ
- FRONT SHELF: CLOSE ACCESS PANEL 214CZ
OR 214BZ
2. REMOVE THE WARNING NOTICE FROM PANELS 29VU
AND 26VU (FIG.1-A AND B)
005

________________
OPERATIONAL
TEST
THIS TEXT IS NOT APPLICABLE
*****

AH

E N D

O F

T E X T

*****

24-21-85
RAI 10000-001
2-400 PAGE
4
MAR 01/15

24-21-85
5

AH

CONTROLS AND INDICATING

RAI 10000-001
MAR15

24-21-85
RAI 10000-001

2-400

PAGE
5
MAR 01/15

24-21-85
6

AH

ACCESS DOORS, C/B PANELS


& SHELVES (90VU - 120VU)

RAI 10000-001
MAR15

24-21-85
RAI 10000-001

2-400

PAGE
6
MAR 01/15

24-21-85
7

AH

REMOVAL AND INSTALLATION


OF RELAY 33XA

RAI 10000-001
MAR15

24-21-85
RAI 10000-001

2-400

PAGE
7
MAR 01/15

24-22-61

ACW GENERATOR 1/2


REMOVAL AND INSTALLATION

RAI 10000-001
1

MAR14

ZONING DATA
___________
ZONE
ACCESS

: 114
435
445
: 114BR 114CR
435AL 445AL 455AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

___
MEN

_________
MAN-HOURS
01

ELAPSED TIME

SPARE

: 01 ACW GENERATOR

242260-01

EXPENDABLE

: 01 O-RING
02 WASHER

242260-01
REF TO CMMV

BULK MATERIAL : SYNTHETIC GREASE


SYNTHETIC OIL

04-004
03-002

PUBLICATION
___________
JIC
JIC
JIC

: ENGINE START (PROPELLER


BRAKE RELEASED) USING
DC GROUND POWER UNIT
: PRATT & WHITNEY CANADA
MAINTENANCE MANUAL
: OPENING AND CLOSING OF
HINGED ENGINE COWLS

AH

72-00-00-ERU-10030
72-01-50-PWC-00000
54-00-00-OAC-10000

24-22-61
RAI 10000-001
2-400 PAGE
1
MAR 01/14

24-22-61

ACW GENERATOR 1/2


REMOVAL AND INSTALLATION

001

RAI 10000-001
2

MAR14

___________
PREPARATION
REF.FIG.242261-RAI-00100
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO DC EXTERNAL POWER RECEPTACLE (ON PANEL 5002VU-B) AND TO AC EXTERNAL
POWER RECEPTACLE (ON PANEL 5000VU-D) AND
THAN THE ACCESS DOORS 114BR(C) AND 114CR(A)
ARE CLOSED
2. ON PANEL 29VU (E) MAKE CERTAIN THAT:
BAT SELECTOR SWITCH 7PA IS IN OFF POSITION
3. DISPLAY A WARNING NOTICE ON PANEL 27VU (F)
AND 29VU, PROHIBITING POWER SUPPLY TO THE
SYSTEM AND ENGINE STARTING.

002

________________________
REMOVAL
OF ACW GENERATOR
REF.FIG.242261-RAI-00110
1. OPEN ENGINE COWLS 435AL(445AL)(A)
2. UNPLUG THE ELECTRICAL CONNECTOR(16)
3. PUT BLANKING CAP ON ELECTRICAL CONNECTOR
4. REMOVE SCREWS(18) AND WASHERS(19) ATTACHING
UPPER CASING AND BONDING BRAID(20)
5. REMOVE SCREWS(21),(7) AND (8) AND WASHERS
(22),(6) AND (9) ATTACHING ELECTRICAL
WIRING AND UPPER CASING
6. REMOVE SCREWS(24) AND WASHERS(23) ATTACHING
THE CASINGS
7. UNSAFETY AND REMOVE CLAMP(5) ATTACHING THE
TWO CASINGS
*** CONTINUED ***
AH

24-22-61
RAI 10000-001
2-400 PAGE
2
MAR 01/14

24-22-61

ACW GENERATOR 1/2


REMOVAL AND INSTALLATION

RAI 10000-001
3

MAR14

8. REMOVE THE TWO VENTILATION CASINGS


9. REMOVAL OF COVER (15)
A. REMOVE SCREW (14), REMOVE AND DISCARD
WASHER (13). REMOVE WASHER (28).
B. IF APPLICABLE, REMOVE SCREW (25),
REMOVE AND DISCARD WASHER (26), REMOVE
WASHER (27).
C. REMOVE COVER (15) OF ELECTRICAL
WIRES (10).
10. REMOVE NUTS(12) AND WASHERS(11) SECURING
THE ELECTRICAL WIRES
11. MARK AND DISCONNECT THE ELECTRICAL WIRES
12. UNSAFETY AND REMOVE CLAMP(4) ATTACHING THE
GENERATOR(17)
NOTE: TAKE ALL RELEVANT PRECAUTIONS NOT DAMAGE
SPLINED DRIVE SHAFT WHEN REMOVING
GENERATOR
13. REMOVE GENERATOR
14. REMOVE AND DISCARD O-RING(1)
15. PUT BLANKING CAPS ON ORIFICES
003

_____________________________
INSTALLATION
OF ACW GENERATOR
REF.FIG.242261-RAI-00110
1. REMOVE BLANKING CAPS FROM ORIFICES
2. POSITION A NEW O-RING(1) PREVIOUSLY
LUBRICATE WITH SYNTHETIC OIL
3. CLEAN AND INSPECT COMPONENT ATTACHMENT
LOCATION AND SURROUNDING AREA
*** CONTINUED ***
AH

24-22-61
RAI 10000-001
2-400 PAGE
3
MAR 01/14

24-22-61

ACW GENERATOR 1/2


REMOVAL AND INSTALLATION

RAI 10000-001
4

MAR14

NOTE: CAREFULLY INSPECT THE PAD SEAL. IF ANY


LEAKS OR DAMAGES ARE FOUND, REFER TO
EMM (PRATT AND WHITNEY CANADA) FOR
REPLACEMENT PROCEDURE.
4. LUBRICATE GENERATOR DRIVE SHAFT BEFORE
INSTALLATION WITH SYNTHETIC GREASE
NOTE:TAKE ALL RELEVANT PRECAUTIONS NOT TO
DAMAGE SPLINED DRIVE SHAFT AND O-RING
WHEN INSTALLING GENERATOR
5. INSTALL GENERATOR(17) ON ENGINE, ALIGN WITH
LOCATORS AND ATTACH BY MEANS OF CLAMP(4)
SAFETY CLAMP
NOTE:THE APPLICABLE TORQUE VALUE IS BETWEEN
0.6 AND 0.7 MDAN(53 TO 61 LBF.IN)
6. CONNECT ELECTRICAL WIRES(10) WITH NUTS(12)
AND WASHERS(11)
NOTE:THE APPLICABLE TORQUE VALUE IS BETWEEN
0.45 AND 0.5 MDAN(39 TO 44 LBF.IN)
7. INSTALLATION OF PROTECTIVE COVER(15)
A. INSTALL PROTECTIVE COVER (15)
B. INSTALL SCREW (14), WASHERS (13) AND
(28).
C. IF APPLICABLE: INSTALL SCREW (25),
WASHERS (26) AND (27).
NOTE: AT EACH REMOVAL AND INSTALLATION
OPERATION OF COVER (15), WASHER (13)
AND IF APPLICABLE, WASHER (26), MUST
BE REPLACED.
D. TIGHTEN SCREW (13) AND IF APPLICABLE,
SCREW (25).
NOTE: THE APPLICABLE TORQUE VALUE IS
BETWEEN 0.147 AND 0.196 M.DAN
(13.01 TO 17.34 LBF.IN).
8. INSTALL THE TWO VENTILATION CASINGS
9. INSTALL CLAMP(5) ATTACHING THE CASINGS BUT
*** CONTINUED ***
AH

24-22-61
RAI 10000-001
2-400 PAGE
4
MAR 01/14

24-22-61

ACW GENERATOR 1/2


REMOVAL AND INSTALLATION

RAI 10000-001
5

MAR14

DO NOT FULLY TIGHTEN AT THIS STAGE


10. INSTALL SCREWS(24) AND WASHERS(23)
ATTACHING THE CASING. TIGHTEN SCREWS
11. INSTALL SCREWS(21),(7) AND (8) AND WASHERS
(22),(6) AND (9) ATTACHING ELECTRICAL
WIRING AND UPPER CASING. TIGHTEN SCREWS
12. INSTALL SCREWS(18) AND WASHERS(19) ATTACHING UPPER CASING AND BONDING BRAID(20)
TIGHTEN SCREWS
NOTE:THE APPLICABLE TORQUE VALUE IS BETWEEN
0.8 AND 0.9 M.DAN(71 TO 80 LBF.IN)
13. FULLY TIGHTEN AND SAFETY CLAMP(5) ATTACHING
THE CASINGS
14. REMOVE BLANKING CAP FROM ELECTRICAL
CONNECTOR(16)
15. PLUG ELECTRICAL CONNECTOR
NOTE:TIGHTENING TORQUE FOR NUTS(2) ATTACHING
ADAPTER(3) : 31 TO 34 MDAN (275 TO 300
LBF.IN)
004

________
CLOSE
UP
REF.FIG.242261-RAI-00100(FIG.1) AND 242261-RAI00110(FIG.2)
1. CLOSE ENGINE COWLS 435AL(445AL)
2. REMOVE WARNING NOTICE FROM PANELS 27VU(FIG.
1-F) AND 29VU(FIG.1-E)

005

_________________________
ENGINE
GROUND IDLE RUN-UP
SEE JOB INSTRUCTION CARD
720000-ERU-10030
*** CONTINUED ***
AH

24-22-61
RAI 10000-001
2-400 PAGE
5
MAR 01/14

24-22-61

ACW GENERATOR 1/2


REMOVAL AND INSTALLATION

006

RAI 10000-001
6

MAR14

______________________________
LEAK
CHECK AFTER ENGINE RUN-UP
SEE JOB INSTRUCTION CARD
(PRATT & WHITNEY CANADA MAINTENANCE MANUAL,
CHAPTER 72-01-50, PAGE BLOCK 500).
1. PERFORM ENGINE RUN-UP AS REQUIRED BY
PRATT & WHITNEY CANADA.
2. CHECK FOR OIL LEAKS AFTER ENGINE SHUT DOWN.

007

______________________________________
SHUT
DOWN OF ENGINE GROUND IDLE RUN-UP
SEE JOB INSTRUCTION CARD
720000-ERU-10030

008

_______________________
OPENING
OF HINGED COWLS
SEE JOB INSTRUCTION CARD
540000-OAC-10000

009

LEAKAGE CHECK AT LEVEL OF ACW GENERATOR


_______________________________________
ATTACHMENT
__________
1. VISUALLY CHECK ENGINE - ACW GENERATOR
CONNECTION FOR LEAKS.
2. IF NECESSARY, RECTIFY LEAKING COMPONENTS AND
REPEAT TEST.

010

______________________________
CLOSING
OF HINGED ENGINE COWLS
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

24-22-61
RAI 10000-001
2-400 PAGE
6
MAR 01/14

24-22-61
7

AH

CONTROL PANEL AND


ACCESS DOORS

RAI 10000-001
MAR14

24-22-61
RAI 10000-001

2-400

PAGE
7
MAR 01/14

24-22-61
8

AH

REMOVAL AND INSTALLATION


OF ACW GENERATOR

RAI 10000-001
MAR14

24-22-61
RAI 10000-001

2-400

PAGE
8
MAR 01/14

24-22-83

ACW BUS TIE CONTACTOR


OPERATIONAL TEST

OPT 10000-001
1

DEC14

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: AC WILD FREQUENCY
EXTERNAL POWER SUPPLY

AH

24-41-00-EAD-10000

24-22-83
OPT 10000-001
2-400 PAGE
1
DEC 01/14

24-22-83

ACW BUS TIE CONTACTOR


OPERATIONAL TEST

001

OPT 10000-001
2

DEC14

___________________________________
ENERGIZATION
OF AIRCRAFT AC NETWORK
SEE JOB INSTRUCTION CARD
244100-EAD-10000

002

__________________________________
BUS
TIE CONTACTOR OPERATIONAL TEST
REF.FIG.242213-OPT-00100-001
1. ON PANEL 101VU (A)
PLACE ELEC/ACW BTC OPNG SWITCH 21XU IN BTC
1 OPEN(BTC 2 OPEN) POSITION
2. ON PANEL 26VU (B) MAKE CERTAIN THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH 18XU IS OFF
- ACW BUS OFF 1(2) CAUTION LIGHT 7XB(8XB)
COMES ON
NOTE: IF THE CREW ALERTING SYSTEM IS ACTIVATED ELEC CAUTION LIGHT ON CREW ALERTING PANEL 175WW COMES ON
3. ON PANEL 101VU
PLACE ELEC/ACW BTC OPNG SWITCH 21XU IN
NORM/FLT POSITION
4. ON PANEL 26VU MAKE CERTAIN THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH 18XU COMES ON
- ACW BUS OFF 1(2) CAUTION LIGHT 7XB(8XB)
GOES OFF

003

______________________________________
DE-ENERGIZATION
OF AIRCRAFT AC NETWORK
SEE JOB INSTRUCTION CARD
244100-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-22-83
OPT 10000-001
2-400 PAGE
2
DEC 01/14

24-22-83
3

AH

CONTROLS AND INDICATING

OPT 10000-001
DEC14

24-22-83
OPT 10000-001

2-400

PAGE
3
DEC 01/14

24-22-83

ACW BUS TIE CONTACTOR


OPERATIONAL TEST

OPT 10000-002
1

DEC14

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC
JIC

: AC WILD FREQUENCY
EXTERNAL POWER SUPPLY
: PRINCIPLE OF CDS USE
(DISPLAY UNITS
EXPLORATION)

AH

24-41-00-EAD-10000
31-63-00-PRO-10000

24-22-83
OPT 10000-002
2-400 PAGE
1
DEC 01/14

24-22-83

ACW BUS TIE CONTACTOR


OPERATIONAL TEST

001

OPT 10000-002
2

DEC14

___________________________________
ENERGIZATION
OF AIRCRAFT AC NETWORK
SEE JOB INSTRUCTION CARD
244100-EAD-10000

002

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

003

__________________________________
BUS
TIE CONTACTOR OPERATIONAL TEST
REF. FIG. 242213-OPT-00100
1. ON PANEL 101VU
PLACE ELEC/ACW BTC OPNG SWITCH IN BTC 1
OPEN (BTC 2 OPEN) POSITION
2. ON PANEL 26VU MAKE CERTAIN THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH IS OFF
- ACW BUS OFF FOR ACW BUS 1(2) CAUTION
LIGHT COMES ON
NOTE: IF THE CREW ALERTING SYSTEM IS ACTIVATED,
ON EWD, IN ALERT WINDOW:
- ELEC ACW BUS 1 (2) MESSAGE AND ACW
BUS 1 (2) OFF ASSOCIATED PROCEDURES
ARE DISPLAYED.
3. ON MFD UPPER WINDOW, IN ACW/HYD SD PAGE:
- LEFT (RIGHT) FLOW BAR IN BTC ITEM SHALL
NOT BE DISPLAYED
*** CONTINUED ***
AH

24-22-83
OPT 10000-002
2-400 PAGE
2
DEC 01/14

24-22-83

ACW BUS TIE CONTACTOR


OPERATIONAL TEST

OPT 10000-002
3

DEC14

- AMBER ACW BUS 1 (2) OFF SYMBOL IS


DISPLAYED
4. ON PANEL 101VU
PLACE ELEC/ACW BTC OPNG SWITCH IN
NORM/FLT POSITION
5. ON PANEL 26VU MAKE CERTAIN THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH COMES ON
- ACW BUS OFF FOR ACW BUS 1(2) CAUTION
LIGHT GOES OFF
6. ON MFD UPPER WINDOW, IN ACW/HYD SD PAGE:
- LEFT (RIGHT) FLOW BAR IN BTC ITEM SHALL
BE DISPLAYED
- GREEN ACW BUS 1 (2) SYMBOL IS DISPLAYED
- ON EWD; IN ALERT WINDOW, ELEC ACW BUS
1 (2) MESSAGE AND ACW BUS 1 (2) OFF
ASSOCIATED PROCEDURES ARE NO LONGER
DISPLAYED.
004

______________________________________
DE-ENERGIZATION
OF AIRCRAFT AC NETWORK
SEE JOB INSTRUCTION CARD
244100-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-22-83
OPT 10000-002
2-400 PAGE
3
DEC 01/14

24-22-83
4

AH

CONTROLS AND INDICATING

OPT 10000-002
DEC14

24-22-83
OPT 10000-002

2-400

PAGE
4
DEC 01/14

24-22-84

ACW GEN CONTROL UNIT


OPERATIONAL TEST

OPT 10000-001
1

MAR13

ZONING DATA
___________
ZONE
ACCESS

: 214
: 214BZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELECTRIC
ELAPSED TIME

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: POWER SUPPLY FROM


BATTERIES

AH

24-31-00-EAD-10000

24-22-84
OPT 10000-001
2-400 PAGE
1
MAR 01/13

24-22-84

ACW GEN CONTROL UNIT


OPERATIONAL TEST

001

OPT 10000-001
2

MAR13

___________
PREPARATION
REF. FIG. 240000-RAI-00103
1. ON R ELECTRONICS RACK 90VU (B)
OPEN ACCESS DOOR 214BZ

002

_________________________________
ENERGIZING
OF SYSTEM FROM BATTERY
SEE JOB INSTRUCTION CARD
243100-EAD-10000

003

___________________________________________
ACW
GENERATOR CONTROL UNIT OPERATIONAL TEST
REF.FIG.242214-OPT-00100
1. ON R ELECTRONICS RACK 90VU SHELF 5(3) (A)
ON ACW GCU 1(2) (B/C) FRONT PANEL PRESS AND
HOLD FOR 10 SECS THE CC SWITCH AND VERIFY
THAT CC INDICATOR LIGHT IS ON.
AFTER 7+/-1 SECS(TESTING TIME),IF GCU OPERATES CORRECTLY, CC INDICATOR LIGHT GOES OFF.
IF A FAILURE IS DETEDTED ON GCU,CC INDICATOR
LIGHT REMAINS ON AS LONG AS CC SWITCH IS
PRESSED.

004

____________________________________
DE-ENERGIZING
OF SYSTEM FROM BATTERY
SEE JOB INSTRUCTION CARD
243100-EAD-10000

005

________
CLOSE
UP
REF.FIG.240000-RAI-00103
1. ON R ELECTRONICS RACK 90VU (B)
CLOSE ACCESS DOOR 214BZ
*****

AH

E N D

O F

T E X T

*****

24-22-84
OPT 10000-001
2-400 PAGE
2
MAR 01/13

24-22-84
3

AH

ACCESS DOORS,CONTROLS
AND INDICATING

OPT 10000-001
MAR13

24-22-84
OPT 10000-001

2-400

PAGE
3
MAR 01/13

24-22-84
4

AH

ACCESS DOORS, C/B PANELS


& SHELVES (90VU - 120VU)

OPT 10000-001
MAR13

24-22-84
OPT 10000-001

2-400

PAGE
4
MAR 01/13

24-22-84

ACW GEN CONTROL UNIT


REMOVAL AND INSTALLATION

RAI 10000-001
1

APR06

ZONING DATA
___________
ZONE
ACCESS

: 212
214
: 122VU
214BZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

MECHANIC

_________
MAN-HOURS

ELAPSED TIME

01

PUBLICATION
___________
JIC

: ACW GEN CONTROL UNIT


OPERATIONAL TEST

AH

24-22-84-OPT-10000

24-22-84
RAI 10000-001
2-400 PAGE
1
APR 01/06

24-22-84

ACW GEN CONTROL UNIT


REMOVAL AND INSTALLATION

001

RAI 10000-001
2

APR06

___________
PREPARATION
REF. FIG. 240000-RAI-00103
1. ON PANEL 122VU (A)
OPEN, SAFETY CLIP AND TAG THE FOLLOWING CIRCUIT BREAKER:
19XU(20XU) ACW ELEC PWR/GCU ACW GEN 1 (ACW
GEN 2)
2. ON R ELECTRONICS RACK 90VU (B)
REMOVE ACCESS DOOR:
- 214BZ

002

REMOVAL OF EQUIPMENT FROM L OR R ELECTRONICS


____________________________________________
RACKS 80VU OR 90VU
__________________
REF. FIG. 310000-RAI-00105
NOTE : THE SHAPE AND QUANTITY OF AFT BACKSHELLS
AS WELL AS THE QUANTITY OF FASTENERS MAY
BE DIFFERENT ACCORDING THE EQUIPMENT.
NEVERTHLESS, THE REMOVAL AND INSTALLATION PROCEDURE IS IDENTICAL.
1. REMOVE CORRESPONDING ACCESS PANEL.
2. UNSCREW KNURLED KNOBS (3) ATTACHING
EQUIPMENT (1) TO RACK (4).
3. PULL EQUIPMENT (1) AND REMOVE FROM ITS
RACK (4).
4. INSTALL PROTECTIVE PLUGS ON EQUIPMENT SIDE
ELECTRICAL CONNECTORS (5).

003

INSTALLATION OF EQUIPMENT IN L OR R ELECTRONICS


_______________________________________________
RACKS 80VU OR 90VU
__________________
REF. FIG. 310000-RAI-00105
*** CONTINUED ***
AH

24-22-84
RAI 10000-001
2-400 PAGE
2
APR 01/06

24-22-84

ACW GEN CONTROL UNIT


REMOVAL AND INSTALLATION

RAI 10000-001
3

APR06

1. CLEAN AND INSPECT EQUIPMENT (1) AND RACK


(4) INTERFACE AREA.
2. REMOVE PROTECTIVE CAPS INSTALLED ON
EQUIPMENT SIDE ELECTRICAL CONNECTORS (5).
3. INSTALL EQUIPMENT (1) IN ITS RACK (4).
4. BLOCK EQUIPMENT BY MEANS OF ITS KNURLED
ATTACHMENT KNOBS (2) AND (3).
004

________
CLOSE
UP
REF.FIG.240000-RAI-00103
1. ON R ELECTRONICS RACK 90VU (B)
CLOSE ACCESS DOOR:
- 214BZ
2. ON PANEL 122VU (A)
REMOVE SAFETY CLIP AND TAG AND CLOSE THE
FOLLOWING CIRCUIT BREAKER:
19XU(20XU)

005

_____________________________________
ACW
GEN CONTROL UNIT OPERATIONAL TEST
SEE JOB INSTRUCTION CARD
242284-OPT-10000
*****

AH

E N D

O F

T E X T

*****

24-22-84
RAI 10000-001
2-400 PAGE
3
APR 01/06

24-22-84
4

AH

ACCESS DOORS, C/B PANELS


& SHELVES (90VU - 120VU)

RAI 10000-001
APR06

24-22-84
RAI 10000-001

2-400

PAGE
4
APR 01/06

24-22-84
5

AH

L AND R ELECTRONICS
RACKS 80VU AND 90VU
EQUIPMENT

RAI 10000-001
APR06

24-22-84
RAI 10000-001

2-400

PAGE
5
APR 01/06

24-31-00

POWER SUPPLY FROM


BATTERIES

EAD 10000-001
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
: 122VU 124VU 125VU

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

AH

24-31-00
EAD 10000-001
2-400 PAGE
1
DEC 01/14

24-31-00

POWER SUPPLY FROM


BATTERIES

001

EAD 10000-001
2

DEC14

___________
PREPARATION
REF.FIG.243100-EAD-00100 (FIG.1)
REF.FIG.243100-EAD-00101 (FIG.2)
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO DC EXTERNAL POWER RECEPTACLE (ON PANEL 5002VU/FIG.2-C) AND THE ACCESS
DOOR 114BR(FIG.2-B) IS CLOSED
2. ON PANEL 29VU(FIG.1-A) MAKE CERTAIN THAT:
- BAT SELECTOR SWITCH IS IN OFF POSITION
- OVRD/UNDV PUSHBUTTON SWITCH IS IN
RELEASED POSITION
- MAIN AND EMER BAT CHG PUSHBUTTON SWITCHES
ARE IN RELEASED POSITION

002

__________
ENERGIZING
REF.FIG.243100-EAD-00100
1. ON PANEL 29VU (A)
PLACE BAT SELECTOR SWITCH 7PA IN ON POSITION
AND CHECK THAT:
- THE TWO ARROW LEGENDS OF BAT TIE CAUTION
LIGHT 6PA COME ON
- BUS OFF 1 AND 2 LEGENDS OF INV FAULT/BUS
OFF CAUTION LIGHTS 7XN AND 8XN COME ON AND
AFTER ABOUT 5 SECS. INV FAULT 2 LEGEND COMES ON TOO

003

_____________
DE-ENERGIZING
REF.FIG.243100-EAD-00100-001
1. ON PANEL 29VU(A)
PLACE BAT SELECTOR SWITCH 7PA IN OFF POSITION
*****

AH

E N D

O F

T E X T

*****

24-31-00
EAD 10000-001
2-400 PAGE
2
DEC 01/14

24-31-00
3

AH

CONTROLS AND INDICATING

EAD 10000-001
DEC14

24-31-00
EAD 10000-001

2-400

PAGE
3
DEC 01/14

24-31-00
4

AH

ACCESS DOORS AND C/B PAN

EAD 10000-001
DEC14

24-31-00
EAD 10000-001

2-400

PAGE
4
DEC 01/14

24-31-00

POWER SUPPLY FROM


BATTERIES

EAD 10000-003
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
: 122VU 124VU 125VU

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELECTRIC

_________
MAN-HOURS

ELAPSED TIME

01

PUBLICATION
___________
JIC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)

AH

31-63-00-PRO-10000

24-31-00
EAD 10000-003
2-400 PAGE
1
DEC 01/14

24-31-00

POWER SUPPLY FROM


BATTERIES

001

EAD 10000-003
2

DEC14

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

002

___________
PREPARATION
REF.FIG.243100-EAD-00100 (FIG.1)
REF.FIG.243100-EAD-00101 (FIG.2)
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO DC EXTERNAL POWER RECEPTACLE (ON PANEL 5002VU/FIG.2-C) AND THE ACCESS
DOOR 114BR(FIG.2-B) IS CLOSED
2. ON PANEL 29VU(FIG.1-A) MAKE CERTAIN THAT:
- BAT SELECTOR SWITCH IS IN OFF POSITION
- OVRD/UNDV PUSHBUTTON SWITCH IS IN
RELEASED POSITION
- MAIN AND EMER BAT CHG PUSHBUTTON SWITCHES
ARE IN RELEASED POSITION

003

__________
ENERGIZING
REF.FIG.243100-EAD-00100
1. ON PANEL 29VU (A)
PLACE BAT SELECTOR SWITCH 7PA IN ON POSITION
AND CHECK THAT:
- THE TWO ARROW LEGENDS OF BAT TIE CAUTION
LIGHT 6PA COME ON
- ON MFD, IN ELEC SD PAGE, THE TWO AMBER
*** CONTINUED ***
AH

24-31-00
EAD 10000-003
2-400 PAGE
2
DEC 01/14

24-31-00

POWER SUPPLY FROM


BATTERIES

EAD 10000-003
3

DEC14

ARROWS ARE DISPLAYED ABOVE EMER AND


MAIN BAT SYMBOLS.
- BUS OFF 1 AND 2 CAUTION LIGHTS FOR
AC BUS 1 AND 2 COME ON AND AFTER ABOUT
5 SECS. INV FAULT 2 CAUTION LIGHTS
FOR INV2 COMES ON TOO.
- ON MFD UPPER WINDOW, IN ELEC SD PAGE,
AC BUS1 OFF AND AC BUS2 OFF SYMBOLS
ARE DISPLAYED AND AFTER 5 SECS, INV 2
FAULT SYMBOL IS DISPLAYED TOO.
004

_____________
DE-ENERGIZING
REF.FIG.243100-EAD-00100-001
1. ON PANEL 29VU(A)
PLACE BAT SELECTOR SWITCH 7PA IN OFF POSITION
*****

AH

E N D

O F

T E X T

*****

24-31-00
EAD 10000-003
2-400 PAGE
3
DEC 01/14

24-31-00
4

AH

CONTROLS AND INDICATING

EAD 10000-003
DEC14

24-31-00
EAD 10000-003

2-400

PAGE
4
DEC 01/14

24-31-00
5

AH

ACCESS DOORS AND C/B PAN

EAD 10000-003
DEC14

24-31-00
EAD 10000-003

2-400

PAGE
5
DEC 01/14

24-31-00

OPERATIONAL TEST OF DC
BATTERY TRANSFER RELAYS

OPT 10000-001
1

DEC14

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

24-46-00-EAD-10000

24-31-00
OPT 10000-001
2-400 PAGE
1
DEC 01/14

24-31-00

OPERATIONAL TEST OF DC
BATTERY TRANSFER RELAYS

001

OPT 10000-001
2

DEC14

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

002

___________________________________________
DC
BATTERY TRANSFER RELAYS OPERATIONAL TEST
REF.FIG.242100-OPT-00100
1. OPEN, SAFETY AND TAGS THE FOLLOWING
CIRCUIT BREAKERS:
CAUTION: OPEN THE FOLLOWING CIRCUIT BREAKERS
IN THE ORDER LISTED BELOW
- ON PANEL 122VU (A)
29XA MAIN ELEC PWR/AC/AC BUS 1 & 2 TIE/26
VAC
30XA MAIN ELEC PWR/AC/AC BUS 1 & 2 TIE/115
VAC
- ON PANEL 124VU (A)
8PA DC EMER/ESS & STBY BUS ON PRIM DC BUS
2/PWR SUPPLY
28PA MAIN BAT CHG CNTOR & BUS V SNSG
- ON PANEL 127VU (A)
9PA DC EMER/ESS & STBY BUS ON PRIM DC BUS
1/PWR SUPPLY
47PA EMER BAT CHG CNTOR
3XA PWR SUPPLY ON PRIM DC BUS 1/INV 1
2. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
A - SINGLE CHIME
B - CAPT AND F/O MASTER CAUTION LIGHTS 13WW
AND 168WW COME ON (B)
C - ON CREW ALERTING PANEL (C)
ELEC CAUTION LIGHT COMES ON
3. ON PANEL 29VU (D) VERIFY THAT:
- THE TWO ARROW LEGENDS OF BAT TIE CAUTION
*** CONTINUED ***
AH

24-31-00
OPT 10000-001
2-400 PAGE
2
DEC 01/14

24-31-00

OPERATIONAL TEST OF DC
BATTERY TRANSFER RELAYS

OPT 10000-001
3

DEC14

LIGHT 6PA COME ON


- BUS OFF 1 LEGEND OF CAUTION LIGHT 7XN
COMES ON
4. REMOVE SAFETY CLIPS AND TAGS AND CLOSE THE
FOLLOWING CIRCUIT BREAKERS:
- ON PANEL 122VU
29XA
30XA
- ON PANEL 124VU
8PA
28PA
- ON PANEL 127VU
9PA
47PA
3XA
5. ON CREW ALERTING PANEL VERIFY THAT:
ELEC CAUTION LIGHT GOES OFF
6. VERIFY THAT:
CAUTION LIGHTS 13WW AND 168WW GO OFF
003

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-31-00
OPT 10000-001
2-400 PAGE
3
DEC 01/14

24-31-00
4

AH

CONTROLS AND INDICATING

OPT 10000-001
DEC14

24-31-00
OPT 10000-001

2-400

PAGE
4
DEC 01/14

24-31-00

OPERATIONAL TEST OF DC
BATTERY TRANSFER RELAYS

OPT 10000-002
1

DEC14

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC
JIC

: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY
: PRINCIPLE OF CDS USE
(DISPLAY UNITS
EXPLORATION)

AH

24-46-00-EAD-10000
31-63-00-PRO-10000

24-31-00
OPT 10000-002
2-400 PAGE
1
DEC 01/14

24-31-00

OPERATIONAL TEST OF DC
BATTERY TRANSFER RELAYS

001

OPT 10000-002
2

DEC14

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

002

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

003

___________________________________________
DC
BATTERY TRANSFER RELAYS OPERATIONAL TEST
REF. FIG. 242100-OPT-00100
1. ON LH EFCP, PRESS CLR PUSH BUTTON
2. OPEN, SAFETY AND TAG THE FOLLOWING
CIRCUIT BREAKERS:
CAUTION: OPEN THE FOLLOWING CIRCUIT BREAKERS
IN THE ORDER LISTED BELOW
- ON PANEL 124VU
8PA DC EMER/ESS & STBY BUS ON PRIM DC BUS
2/PWR SUPPLY
28PA MAIN BAT CHG CNTOR & BUS V SNSG
10XA PWR SUPPLY ON PRIM DC BUS 2/INV 2
- ON PANEL 127VU
47PA EMER BAT CHG CNTOR
9PA DC EMER/ESS & STBY BUS ON PRIM DC BUS
*** CONTINUED ***
AH

24-31-00
OPT 10000-002
2-400 PAGE
2
DEC 01/14

24-31-00

OPERATIONAL TEST OF DC
BATTERY TRANSFER RELAYS

OPT 10000-002
3

DEC14

1/PWR SUPPLY
3XA PWR SUPPLY ON PRIM DC BUS 1/INV 1
3. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
A - SINGLE CHIME
B - MASTER CAUTION LIGHTS COME ON
C - ON EWD, IN ALERT WINDOW (DO NOT PAY
ATTENTION TO OTHER MESSAGES)
. ELEC AC BUS 1 MESSAGE AND AC BUS 1
OFF ASSOCIATED PROCEDURES ARE
DISPLAYED MESSAGE IS DISPLAYED
. ELEC AC BUS 2 MESSAGE AND AC BUS 2
OFF ASSOCIATED PROCEDURES ARE
DISPLAYED
. ELEC INV 2 MESSAGE AND INV FAULT
ASSOCIATED PROCEDURES ARE DISPLAYED
4. ON PANEL 29VU VERIFY THAT:
- THE TWO ARROW LEGENDS OF BAT TIE CAUTION
LIGHT COME ON
- BUS OFF FOR AC BUS 1 CAUTION LIGHT
COMES ON
- BUS OFF FOR AC BUS 2 CAUTION LIGHT
COMES ON
- INV FAULT FOR INV 2 CAUTION LIGHT
COMES ON
ON MFD UPPER WINDOW, IN ELEC SD PAGE,
THE FOLLOWING INDICATIONS ARE DISPLAYED
- AMBER ARROW ON EMER BAT
- AMBER ARROW ON MAIN BAT
- AMBER AC BUS 1 OFF SYMBOL
- AMBER AC BUS 2 OFF SYMBOL
- GREEN AC BUS STBY SYMBOL
- GREEN INV 1 SYMBOL
- AMBER INV 2 FAULT SYMBOL
5. CLOSE THE CIRCUIT BREAKERS PREVIOUSLY
OPENED.
*** CONTINUED ***
AH

24-31-00
OPT 10000-002
2-400 PAGE
3
DEC 01/14

24-31-00

OPERATIONAL TEST OF DC
BATTERY TRANSFER RELAYS

OPT 10000-002
4

DEC14

6. ON EWD, IN ALERT WINDOW


- ELEC AC BUS 1 MESSAGE AND AC BUS 1
OFF ASSOCIATED PROCEDURES ARE NO LONGER
DISPLAYED
DISPLAYED
- ELEC AC BUS 2 MESSAGE AND AC BUS 2
OFF ASSOCIATED PROCEDURES ARE NO LONGER
DISPLAYED
- ELEC INV 2 MESSAGE AND INV FAULT
ASSOCIATED PROCEDURES ARE NO LONGER
DISPLAYED
7. VERIFY THAT:
MASTER CAUTION LIGHTS GO OFF
004

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-31-00
OPT 10000-002
2-400 PAGE
4
DEC 01/14

24-31-00
5

AH

CONTROLS AND INDICATING

OPT 10000-002
DEC14

24-31-00
OPT 10000-002

2-400

PAGE
5
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY OVRD AND EMER
INDICATING

OPT 10010-001
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC

: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

24-46-00-EAD-10000

24-31-00
OPT 10010-001
2-400 PAGE
1
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY OVRD AND EMER
INDICATING

001

OPT 10010-001
2

DEC14

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

002

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

003

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

________________
OPERATIONAL
TEST
REF.FIG.242100-OPT-00100 (FIG.1)
243100-EAD-00101 (FIG.2)
1. ON PANEL 29VU (FIG.1-D)
PLACE BAT SELECTOR SWITCH 7PA IN OVRD POSITION AND VERIFY THAT:
- THE TWO ARROW LEGENDS OF BAT TIE CAUTION
LIGHT 6PA COME ON
- INV FAULT 1 LEGEND OF CAUTION LIGHT 7XN
IS OFF
- UNDV AND OVRD LEGEND ON PUSHBUTTON SWITCH
9PD ARE OFF
- ON PANEL 175WW (FIG.1-C)
ELEC CAUTION LIGHT COMES ON
- CAPT AND F/O MASTER CAUTION LIGHTS 13WW
AND 168WW COME ON (FIG 1-B)
- SINGLE CHIME SOUNDS
2. OPEN SAFETY CLIP AND TAG THE FOLLOWING
CIRCUIT BREAKER:
ON PANEL 129VU (FIG.2-A)
4XA INV 1 ON HOT MAIN BAT BUS
*** CONTINUED ***
AH

24-31-00
OPT 10010-001
2-400 PAGE
2
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY OVRD AND EMER
INDICATING

OPT 10010-001
3

DEC14

3. ON PANEL 29VU VERIFY THAT:


BUS OFF 1 LEGEND OF CAUTION LIGHT 7XN
COMES ON
SINGLE CHIME SOUNDS
4. AFTER 10 SEC VERIFY THAT:
- ON PANEL 29VU
INV FAULT 1 LEGEND OF CAUTION LIGHT 7XN
COMES ON
5. OPEN SAFETY CLIP AND TAG THE FOLLOWING
CIRCUIT BREAKER:
ON PANEL 129VU
3PD DC STBY BUS ON HMBB
6. ON PANEL 29VU VERIFY THAT:
- UNDV LEGEND ON PUSHBUTTON SWITCH 9PD
COMES ON
7. ON PANEL 175WW
ELEC CAUTION LIGHT REMAIN ON
8. CAPT AND F/O MASTER CAUTION LIGHTS 13WW
AND 168WW REMAIN ON (FIG. 1-B)
9. REMOVE SAFETY CLIPS AND TAGS AND CLOSE
THE FOLLOWING CIRCUIT BREAKERS:
ON PANEL 129VU
4XA
3PD
10. ON PANEL 29VU
PLACE BAT SELECTOR SWITCH 7PA IN ON
POSITION AND VERIFY THAT:
- ON PANEL 175WW
ELEC CAUTION LIGHT GOES OFF
- CAPT AND F/O MASTER CAUTION LIGHTS 13WW
AND 168WW GO OFF

*** CONTINUED ***


AH

24-31-00
OPT 10010-001
2-400 PAGE
3
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY OVRD AND EMER
INDICATING

004

OPT 10010-001
4

DEC14

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-31-00
OPT 10010-001
2-400 PAGE
4
DEC 01/14

24-31-00
5

AH

CONTROLS AND INDICATING

OPT 10010-001
DEC14

24-31-00
OPT 10010-001

2-400

PAGE
5
DEC 01/14

24-31-00
6

AH

ACCESS DOORS AND C/B PAN

OPT 10010-001
DEC14

24-31-00
OPT 10010-001

2-400

PAGE
6
DEC 01/14

24-31-00
7

AH

UTILIZATION OF MFC
MAINTENANCE MEMORY

OPT 10010-001
DEC14

24-31-00
OPT 10010-001

2-400

PAGE
7
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY OVRD AND EMER
INDICATING

OPT 10010-002
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC

: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

24-46-00-EAD-10000

24-31-00
OPT 10010-002
2-400 PAGE
1
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY OVRD AND EMER
INDICATING

001

OPT 10010-002
2

DEC14

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

002

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

003

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

________________
OPERATIONAL
TEST
REF.FIG.242100-OPT-00100 (FIG.1)
243100-EAD-00101 (FIG.2)
1. ON PANEL 29VU (FIG.1-D)
PLACE BAT SELECTOR SWITCH 7PA IN OVRD POSITION AND VERIFY THAT:
- THE TWO ARROW LEGENDS OF BAT TIE CAUTION
LIGHT 6PA COME ON
- INV FAULT 1 LEGEND OF CAUTION LIGHT 7XN
IS OFF
- UNDV AND OVRD LEGEND ON PUSHBUTTON SWITCH
9PD ARE OFF
- ON PANEL 175WW (FIG.1-C)
ELEC CAUTION LIGHT COMES ON
- CAPT AND F/O MASTER CAUTION LIGHTS 13WW
AND 168WW COME ON (FIG 1-B)
- SINGLE CHIME SOUNDS
2. OPEN SAFETY CLIP AND TAG THE FOLLOWING
CIRCUIT BREAKER:
ON PANEL 129VU (FIG.2-A)
4XA INV 1 ON HOT MAIN BAT BUS
*** CONTINUED ***
AH

24-31-00
OPT 10010-002
2-400 PAGE
2
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY OVRD AND EMER
INDICATING

OPT 10010-002
3

DEC14

3. ON PANEL 29VU VERIFY THAT:


BUS OFF 1 LEGEND OF CAUTION LIGHT 7XN
COMES ON
SINGLE CHIME SOUNDS
4. AFTER 10 SEC VERIFY THAT:
- ON PANEL 29VU
INV FAULT 1 LEGEND OF CAUTION LIGHT 7XN
COMES ON
5. OPEN SAFETY CLIP AND TAG THE FOLLOWING
CIRCUIT BREAKER:
ON PANEL 129VU
3PD DC STBY BUS ON HMBB
6. ON PANEL 29VU VERIFY THAT:
- UNDV LEGEND ON PUSHBUTTON SWITCH 9PD
COMES ON
7. ON PANEL 175WW
ELEC CAUTION LIGHT REMAIN ON
8. CAPT AND F/O MASTER CAUTION LIGHTS 13WW
AND 168WW REMAIN ON (FIG. 1-B)
9. REMOVE SAFETY CLIPS AND TAGS AND CLOSE
THE FOLLOWING CIRCUIT BREAKERS:
ON PANEL 129VU
4XA
3PD
10. ON PANEL 29VU
PLACE BAT SELECTOR SWITCH 7PA IN ON
POSITION AND VERIFY THAT:
- ON PANEL 175WW
ELEC CAUTION LIGHT GOES OFF
- CAPT AND F/O MASTER CAUTION LIGHTS 13WW
AND 168WW GO OFF

*** CONTINUED ***


AH

24-31-00
OPT 10010-002
2-400 PAGE
3
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY OVRD AND EMER
INDICATING

004

OPT 10010-002
4

DEC14

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-31-00
OPT 10010-002
2-400 PAGE
4
DEC 01/14

24-31-00
5

AH

CONTROLS AND INDICATING

OPT 10010-002
DEC14

24-31-00
OPT 10010-002

2-400

PAGE
5
DEC 01/14

24-31-00
6

AH

ACCESS DOORS AND C/B PAN

OPT 10010-002
DEC14

24-31-00
OPT 10010-002

2-400

PAGE
6
DEC 01/14

24-31-00
7

AH

UTILIZATION OF MFC
MAINTENANCE MEMORY

OPT 10010-002
DEC14

24-31-00
OPT 10010-002

2-400

PAGE
7
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY OVRD AND EMER
INDICATING

OPT 10010-003
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC

: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY
: PRINCIPLE OF CDS USE
(DISPLAY UNITS
EXPLORATION)

AH

24-46-00-EAD-10000
31-63-00-PRO-10000

24-31-00
OPT 10010-003
2-400 PAGE
1
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY OVRD AND EMER
INDICATING

001

OPT 10010-003
2

DEC14

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

002

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

003

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

004

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

________________
OPERATIONAL
TEST
REF. FIG. 242100-OPT-00100
REF. FIG. 243100-EAD-00101
1. ON PANEL 127VU, OPEN, SAFETY AND TAG
THE FOLLOWING CIRCUIT BREAKER:
3XA
PWR SUPPLY ON PRIM DC BUS 1/INV 1
2. ON PANEL 29VU:
*** CONTINUED ***
AH

24-31-00
OPT 10010-003
2-400 PAGE
2
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY OVRD AND EMER
INDICATING

OPT 10010-003
3

DEC14

PLACE BAT SELECTOR SWITCH IN OVRD POSITION


AND VERIFY THAT:
- MASTER CAUTION LIGHTS COME ON
- THE TWO ARROW LEGENDS OF BAT TIE CAUTION
LIGHTS COME ON
- INV FAULT FOR INV 1 LEGEND OF CAUTION
LIGHT IS OFF
- UNDV AND OVRD LEGENDS ON PUSHBUTTON
SWITCH ARE OFF
- ON MFD UPPER WINDOW, IN ELEC SD PAGE,
THE FOLLOWING INDICATIONS ARE DISPLAYED:
- AMBER ARROW IS DISPLAYED ON EMER BAT
- AMBER ARROW IS DISPLAYED ON MAIN BAT
- OVRD LEGEND IS DISPLAYED UNDER EMER BAT
- OVRD LEGEND IS DISPLAYED UNDER MAIN BAT
- GREEN INV 1 SYMBOL IS DISPLAYED
- GREEN AC STBY BUS SYMBOL IS DISPLAYED
- GREEN EMER BUS SYMBOL IS DISPLAYED
- GREEN ESS BUS SYMBOL IS DISPLAYED
- GREEN DC STBY BUS SYMBOL IS DISPLAYED
- NO UNDV OR OVRD LEGENDS ARE ON
DC STBY BUS SYMBOL
- GREEN AC BUS 1 AND AC BUS 2 SYMBOLS
ARE DISPLAYED.
3. ON LH EFCP, PRESS CLR PUSH BUTTON.
4. OPEN, SAFETY AND TAG THE FOLLOWING
CIRCUIT BREAKER:
ON PANEL 129VU:
4XA
INV 1 ON HOT MAIN BAT BUS
5. VERIFY THAT THE CREW ALERTING SYSTEM
IS ACTIVATED IN THE FOLLOWING WAY:
- SINGLE CHIME SOUNDS
- MASTER CAUTION LIGHTS REMAIN ON
- ON EWD, IN ALERT WINDOW, ELEC AC BUS 1
MESSAGE AND AC BUS 1 OFF ASSOCIATED
PROCEDURES ARE DISPLAYED.
- ON PANEL 29VU, BUS OFF FOR AC BUS 1
CAUTION LIGHT COMES ON
*** CONTINUED ***
AH

24-31-00
OPT 10010-003
2-400 PAGE
3
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY OVRD AND EMER
INDICATING

OPT 10010-003
4

DEC14

- ON MFD UPPER WINDOW, IN ELEC SD PAGE,


AMBER AC BUS 1 OFF SYMBOL IS
DISPLAYED.
6. 10 SEC AFTER C/B OPENING, CHECK THAT:
- ON EWD,IN ALERT WINDOW, ELEC INV 1
MESSAGE AND INV FAULT ASSOCIATED
PROCEDURES ARE DISPLAYED.
- ELEC AC BUS 1 MESSAGE AND AC BUS 1 OFF
ASSOCIATED PROCEDURES ARE NO LONGER
DISPLAYED.
- ON PANEL 29VU, BUS OFF FOR AC BUS 1
CAUTION LIGHT GOES OFF
- ON MFD UPPER WINDOW, IN ELEC SD PAGE,
GREEN AC BUS 1 AND AMBER INV 1 FAULT
SYMBOLS ARE DISPLAYED
- ON PANEL 29VU, INV FAULT FOR INV 1
CAUTION LIGHT COMES ON.
7. OPEN, SAFETY AND TAG THE FOLLOWING
CIRCUIT BREAKER:
ON PANEL 129VU:
3PD
DC STBY BUS ON HMBB
8. VERIFY THAT
- ON PANEL 29VU, UNDV LEGEND ON OVRD/
UNDV PUSHBUTTON SWITCH COMES ON
- ON MFD UPPER WINDOW, IN ELEC SD PAGE,
UNDV MESSAGE IS DISPLAYED ABOVE AMBER
DC STBY BUS SYMBOL.
9. ON EWD, IN ALERT WINDOW (DO NOT PAY
ATTENTION TO OTHER MESSAGES)
- ELEC DC STBY BUS MESSAGE AND DC STBY
BUS FAULT ASSOCIATED PROCEDURES ARE
DISPLAYED.
10. MASTER CAUTION LIGHTS REMAIN ON.
11. CLOSE CIRCUIT BREAKERS PREVIOUSLY OPENED.
*** CONTINUED ***
AH

24-31-00
OPT 10010-003
2-400 PAGE
4
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY OVRD AND EMER
INDICATING

OPT 10010-003
5

DEC14

12. ON PANEL 29VU:


PLACE BAT SELECTOR SWITCH IN ON
POSITION AND VERIFY THAT:
- ON EWD, IN ALERT WINDOW
NO MESSAGES RELATED TO AC BUS / INV /
DC STBY BUS AND THEIR ASSOCIATED
PROCEDURES ARE DISPLAYED.
- MASTER CAUTION LIGHTS GO OFF
- ON MFD UPPER WINDOW, IN ELEC SD PAGE,
GREEN INV 1 SYMBOL IS DISPLAYED
- ON PANEL 29VU, INV FAULT FOR INV 1
CAUTION LIGHT GOES OFF.
005

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-31-00
OPT 10010-003
2-400 PAGE
5
DEC 01/14

24-31-00
6

AH

CONTROLS AND INDICATING

OPT 10010-003
DEC14

24-31-00
OPT 10010-003

2-400

PAGE
6
DEC 01/14

24-31-00
7

AH

ACCESS DOORS AND C/B PAN

OPT 10010-003
DEC14

24-31-00
OPT 10010-003

2-400

PAGE
7
DEC 01/14

24-31-00
8

AH

UTILIZATION OF MFC
MAINTENANCE MEMORY

OPT 10010-003
DEC14

24-31-00
OPT 10010-003

2-400

PAGE
8
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY FAULT
INDICATING

OPT 10020-002
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
213
221
: 213AZ 221AZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC
MECHANIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01
01

PUBLICATION
___________
JIC

: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

24-46-00-EAD-10000

24-31-00
OPT 10020-002
2-400 PAGE
1
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY FAULT
INDICATING

001

OPT 10020-002
2

DEC14

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

002

___________
PREPARATION
REF.FIG.243117-OPT-00100
1. ON L ELECTRONICS RACK 80VU:
OPEN CORRESPONDING ACCESS DOOR:
- MAIN BATTERY : 213AZ
- EMER BATTERY : 221AZ

003

________________
OPERATIONAL
TEST
REF. FIG. 243100-OPT-00120
REF. FIG. 243117-OPT-00100
01. ON PANEL 25VU (D)
RELEASE MFC/1A AND 1B PUSHBUTTON SWITCHES
7UA1 AND 6UA1
- OFF LEGENDS COME ON
02. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
A. SINGLE CHIME
B. ON PANELS 3VU AND 5VU (FIG.1-A)
CAPT AND F/O MASTER CAUTION LIGHTS 13WW
AND 168WW COME ON
C. ON PANEL 175WW (FIG.1-B)
MFC AND ELEC CAUTION LIGHTS COME ON
03. ON PANEL 29VU (FIG.1-C)
BUS OFF 1 LEGEND OF INV FAULT/BUS OFF
CAUTION LIGHT 7XN COMES ON
04. ON PANEL 175WW
PRESS CLR AND CHECK THAT THE ALERTS GO OFF
*** CONTINUED ***
AH

24-31-00
OPT 10020-002
2-400 PAGE
2
DEC 01/14

OPERATIONAL TEST OF
BATTERY FAULT
INDICATING

24-31-00

OPT 10020-002
3

DEC14

05. ON L ELECTRONICS RACK 80 VU (FIG.2-A)


UNPLUG CONNECTOR 21PAB (72PAB) FROM MAIN
(EMER) BATTERY 21PA (72PA) AND BRIDGE THE
PINS C AND D OF THE SAME CONNECTOR
06. ON PANEL 29VU (FIG.1-C) VERIFY THAT
FAULT LEGEND ON MAIN (EMER) PUSHBUTTON
SWITCH 35PA (45PA) COMES ON
07. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
A. SINGLE CHIME
B. ON PANELS 3VU AND 5VU
CAPT AND F/O MASTER CAUTION LIGHTS 13WW
AND 168WW COME ON
C. ON PANEL 175WW
ELEC CAUTION LIGHT COMES ON
08. ON L ELECTRONICS RACK 80VU
A. REMOVE THE BRIDGE BETWEEN PINS C AND D
OF THE CONNECTOR 21PAB (72PAB)
B. PLUG THE CONNECTOR 21PAB(72PAB) TO THE
MAIN (EMER) BATTERY 21PA(72PA).
09. RELEASE AND PRESS PUSHBUTTON SWITCH 35PA
(45PA) AND VERIFY THAT:
A. ON PANEL 29VU
FAULT LEGEND ON PUSHBUTTON SWITCH 35PA
(45PA) GOES OFF
B. ON PANEL 175WW
ELEC CAUTION LIGHT GOES OFF
C. ON PANELS 3VU AND 5VU
CAUTION LIGHTS 13WW AND 168WW GO OFF
10. ON PANEL 25VU
PRESS PUSHBUTTON SWITCHES 7UA1 AND 6UA1
OFF LEGENDS GO OFF
11. ON PANEL 175WW
WAIT 10 SECONDS THEN PRESS CLR AND CHECK
THAT THE ALERTS GO OFF.
*** CONTINUED ***
AH

24-31-00
OPT 10020-002
2-400 PAGE
3
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY FAULT
INDICATING

OPT 10020-002
4

DEC14

12. ON PANEL 25VU


RELEASE MFC/2A AND 2B PUSHBUTTON SWITCHES
7UA2 AND 6UA2
OFF LEGENDS COME ON
13. PERFORM THE SAME TEST FROM STEP 02 TO STEP
09 INCLUDED.
NOTE:
A. AT THE STEP 02.C. ONLY THE MFC CAUTION
LIGHT COMES ON.
B. AT THE STEP 03. BUS OFF 2 LEGEND OF
INV FAULT/BUS OFF CAUTION LIGHT 8XN
REMAINS OFF.
14. ON PANEL 25VU
PRESS PUSHBUTTON SWITCHES 7UA2 AND 6UA2
- OFF LEGENDS GO OFF
15. ON PANEL 175WW
WAIT 10 SECONDS THEN PRESS CLR AND CHECK
THAT THE ALERTS GO OFF.
NOTE: THE VENTILATION TO ELECTRONICS RACKS
IS ACTIVATED AFTER ABOUT 120 SECONDS
004

________
CLOSE-UP
REF. FIG. 243117-OPT-00100
1. ON L ELECTRONICS RACK 80VU:
CLOSE CORRESPONDING ACCESS DOOR:
- MAIN BATTERY : 213AZ
- EMER BATTERY : 221AZ

005

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-31-00
OPT 10020-002
2-400 PAGE
4
DEC 01/14

24-31-00
5

AH

CONTROLS AND INDICATING

OPT 10020-002
DEC14

24-31-00
OPT 10020-002

2-400

PAGE
5
DEC 01/14

24-31-00
6

AH

ACCESS DOORS

OPT 10020-002
DEC14

24-31-00
OPT 10020-002

2-400

PAGE
6
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY FAULT
INDICATING

OPT 10020-003
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
213
221
: 213AZ 221AZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC
MECHANIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01
01

PUBLICATION
___________
JIC
JIC

: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY
: PRINCIPLE OF CDS USE
(DISPLAY UNITS
EXPLORATION)

AH

24-46-00-EAD-10000
31-63-00-PRO-10000

24-31-00
OPT 10020-003
2-400 PAGE
1
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY FAULT
INDICATING

001

OPT 10020-003
2

DEC14

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

002

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

003

___________
PREPARATION
REF.FIG.243117-OPT-00100
1. ON L ELECTRONICS RACK 80VU:
OPEN CORRESPONDING ACCESS DOOR:
- MAIN BATTERY : 213AZ
- EMER BATTERY : 221AZ

004

________________
OPERATIONAL
TEST
REF. FIG. 243100-OPT-00120
REF. FIG. 243117-OPT-00100
01. - ON LH EFCP, PRESS CLR PUSH BUTTON
- ON PANEL 25VU:
RELEASE MFC/1A AND 1B PUSHBUTTON SWITCHES
.OFF LEGENDS COME ON.
02. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
*** CONTINUED ***
AH

24-31-00
OPT 10020-003
2-400 PAGE
2
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY FAULT
INDICATING

OPT 10020-003
3

DEC14

A. SINGLE CHIME
B. ON PANELS 133VU(VM) AND 134VU(VM),
MASTER CAUTION LIGHTS COME ON.
C. ON EWD, IN ALERT WINDOW (DO NOT PAY
ATTENTION TO OTHER MESSAGES)
MFC 1A+1B MESSAGE IS DISPLAYED
ELEC AC BUS 1 MESSAGE AND AC BUS 1
OFF ASSOCIATED PROCEDURES ARE
DISPLAYED
03. ON PANEL 29VU:
-BUS OFF CAUTION LIGHT COMES FOR AC BUS 1
COMES ON.
-ON MFD UPPER WINDOW, ON ELEC SD PAGE,
AMBER AC BUS 1 OFF SYMBOL IS DISPLAYED.
04. ON LH EFCP, PRESS CLR PUSH BUTTON.
05. ON L ELECTRONICS RACK 80 VU:
UNPLUG CONNECTORS 21PAB AND 72PAB
RESPECTIVELY FROM MAIN AND EMER BATTERIES
AND BRIDGE THE PINS C AND D OF THE SAME
CONNECTORS.
06. VERIFY THAT:
A. ON PANEL 29VU:
- FAULT LEGENDS ON MAIN AND EMER
PUSHBUTTON SWITCHES COME ON.
- THE TWO ARROW LEGENDS OF BAT TIE
CAUTION LIGHTS MOMENTARILY COME ON.
B. ON MFD UPPER WINDOW, IN ELEC SD PAGE,
AMBER CHG FAULT SYMBOLS AT RIGHT AND
LEFT SIDES OF MAIN AND EMER BAT ARE
DISPLAYED.
07. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
A. SINGLE CHIME
B. ON PANELS 133VU(VM) AND 134VU(VM),
MASTER CAUTION LIGHTS COME ON.
C. ON EWD, IN ALERT WINDOW (DO NOT PAY
*** CONTINUED ***
AH

24-31-00
OPT 10020-003
2-400 PAGE
3
DEC 01/14

OPERATIONAL TEST OF
BATTERY FAULT
INDICATING

24-31-00

OPT 10020-003
4

DEC14

ATTENTION TO OTHER MESSAGES):


-ELEC CHG LOSS MESSAGE AND EMER +
MAIN BAT CHG LOSS ASSOCIATED PROCEDURES
ARE DISPLAYED.
08. ON L ELECTRONICS RACK 80VU:
REMOVE THE BRIDGE BETWEEN PINS C AND D OF
THE CONNECTORS 21PAB AND 72PAB AND PLUG
THE CONNECTORS INTO MAIN AND EMER BATTERIES
09. RELEASE AND PRESS MAIN AND EMER BAT CHG
PUSHBUTTON SWITCHES AND VERIFY THAT:
A. ON PANEL 29VU:
FAULT LEGENDS ON PUSHBUTTON SWITCHES
GO OFF.
B. ON MFD UPPER WINDOW, IN SD ELEC PAGE
CHG LABELS AT RIGHT AND LEFT SIDES
OF MAIN AND EMER BAT ITEM ARE DISPLAYED.
C. ON EWD, IN ALERT WINDOW, ELEC CHG
LOSS MESSAGE AND EMER + MAIN BAT CHG
LOSS ASSOCIATED PROCEDURES ARE NOT
DISPLAYED.
D. ON PANELS 133VU(VM) AND 134VU(VM),
MASTER CAUTION LIGHTS GO OFF.
10. ON PANEL 25VU:
PRESS MFC/1A AND 1B PUSHBUTTON SWITCHES.
- OFF LEGENDS GO OFF.
11. ON EWD, IN ALERT WINDOW:
- MFC 1A + 1B MESSAGE IS NOT DISPLAYED.
-ELEC AC BUS 1 MESSAGE AND AC BUS 1
OFF ASSOCIATED PROCEDURES ARE NOT
DISPLAYED.
12. ON PANEL 29VU, BUS OFF CAUTION LIGHT FOR
AC BUS 1 GOES OFF.
13. ON MFD UPPER WINDOW, ON ELEC SD PAGE, THE
GREEN AC BUS 1 SYMBOL IS DISPLAYED.
*** CONTINUED ***
AH

24-31-00
OPT 10020-003
2-400 PAGE
4
DEC 01/14

24-31-00

OPERATIONAL TEST OF
BATTERY FAULT
INDICATING

OPT 10020-003
5

DEC14

14. ON PANEL 25VU:


RELEASE MFC/2A AND 2B PUSHBUTTON SWITCHES.
- OFF LEGENDS COME ON.
15. PERFORM THE SAME TEST FROM STEP 2 TO 10.
NOTE: AT STEP 2, NO ELEC MESSAGE WILL BE
DISPLAYED. AT STEP 3, NO BUS OFF CAUTION
LIGHTS FOR AC BUSES WILL COME ON.
16. ON PANEL 25VU:
PRESS MFC/2A AND 2B PUSHBUTTON SWITCHES.
- OFF LEGENDS GO OFF.
NOTE: THE VENTILATION TO ELECTRONICS RACKS
IS ACTIVATED AFTER ABOUT 120 SECONDS.
005

________
CLOSE-UP
REF. FIG. 243117-OPT-00100
1. ON L ELECTRONICS RACK 80VU:
CLOSE CORRESPONDING ACCESS DOOR:
- MAIN BATTERY : 213AZ
- EMER BATTERY : 221AZ

006

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-31-00
OPT 10020-003
2-400 PAGE
5
DEC 01/14

24-31-00
6

AH

CONTROLS AND INDICATING

OPT 10020-003
DEC14

24-31-00
OPT 10020-003

2-400

PAGE
6
DEC 01/14

24-31-00
7

AH

ACCESS DOORS

OPT 10020-003
DEC14

24-31-00
OPT 10020-003

2-400

PAGE
7
DEC 01/14

24-31-81

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT

OPT 10000-001
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
MECHANIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: ENGINE START (PROPELLER


BRAKE RELEASED) USING
DC GROUND POWER UNIT

AH

72-00-00-ERU-10030

24-31-81
OPT 10000-001
2-400 PAGE
1
DEC 01/14

24-31-81

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT

001

OPT 10000-001
2

DEC14

____
NOTE
THIS JOB CARD INSTRUCTION WILL BE CARRIED OUT
WITH ENGINE RUNNING OR WITH AC WILD FREQUENCY
EXTERNAL PWR.
FOR EXTERNAL POWER PROCEDURE, USE JOB
INSTRUCTION CARD 243181-OPT-10005.

002

_________________________
ENGINE
GROUND IDLE RUN-UP
SEE JOB INSTRUCTION CARD
720000-ERU-10030

003

___________
PREPARATION
REF.FIG.243181-OPT-00100
1. MAKE CERTAIN THAT THE GROUND POWER UNIT
IS NOT CONNECTED TO DC EXTERNAL POWER
RECEPTACLE (ON PANEL 5002VU) AND THE
ACCESS DOOR 114BR IS CLOSED.
2. ON PANEL 29VU (B)
RELEASE DC GEN 1 PUSHBUTTON SWITCH
AND DC GEN 2 PUSHBUTTON SWITCHES.

004

________________
OPERATIONAL
TEST
REF.FIG.243181-OPT-00100
1. ON PANEL 29VU (B) CHECK THAT:
- ARROW LEGENDS OF BAT TIE CAUTION LIGHT
ARE ON
- BUS OFF FOR AC BUS 1 CAUTION LIGHTS
IS ON
- BUS OFF FOR AC BUS 2 AND INV FAULT FOR
INV 2 CAUTION LIGHTS ARE ON
- DC BUS OFF CAUTION LIGHTS FOR DC BUS 1
AND 2 COME ON
- SHED LEGEND OF DC SVCE/UTLY BUS PUSHBUTTON
SWITCH IS ON
*** CONTINUED ***
AH

24-31-81
OPT 10000-001
2-400 PAGE
2
DEC 01/14

24-31-81

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT

OPT 10000-001
3

DEC14

2. VERIFY THAT THE FOLLOWING SYSTEMS ARE


SUPPLIED:
- VHF 1
- FUEL QTY INDICATOR
- FLAPS POSITION INDICATOR
3. ON PANEL 29VU
A. PRESS TRU PUSHBUTTON SWITCH
- ON AND ARROW LEGENDS COME ON
B. VERIFY THAT THE TWO ARROW LEGENDS OF BAT
TIE CAUTION LIGHT GO OFF
C. CHECK THAT UNDV LEGEND OF OVRD/UNDV PUSHBUTTON SWITCH IS STILL OFF
4. ON PANEL 129VU (A)
OPEN SAFETY CLIPS AND TAGS THE FOLLOWING
CIRCUIT BREAKERS:
11PA DC ESS/STBY BUS ON HMBB/GEN PWR
SPLY
4XA INV 1 HOT MAIN BAT BUS
5. ON PANEL 130VU (A)
OPEN SAFETY CLIPS AND TAGS THE FOLLOWING
CIRCUIT BREAKERS:
64PA DC EMER & STBY BUS ON HEBB/GENERAL
PWR SPLY
7XA INV 1 ON HOT EMER BAT BUS
6. ON PANEL 29VU
VERIFY THAT BATTERY AMMETER SHOWS ZERO
LOAD EITHER IF BAT SEL SWITCH IS PLACED IN
EMER OR IN MAIN POSITION
7. VERIFY THAT THE FOLLOWING SYSTEMS ARE
STILL SUPPLIED:
- VHF 1
- FUEL QTY INDICATOR
- FLAPS POSITION INDICATOR
8. ON PANEL 29VU
CHECK THAT INV FAULT 1 LEGEND OF CAUTION
*** CONTINUED ***
AH

24-31-81
OPT 10000-001
2-400 PAGE
3
DEC 01/14

24-31-81

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT

OPT 10000-001
4

DEC14

LIGHT IS OFF
9. ON PANEL 129VU
REMOVE SAFETY CLIPS AND TAGS AND CLOSE THE
FOLLOWING CIRCUIT BREAKERS:
11PA
4XA
10. ON PANEL 130VU
REMOVE SAFETY CLIPS AND TAGS AND CLOSE THE
FOLLOWING CIRCUIT BREAKERS:
64PA
7XA
NOTE: ON ELECTRONICS RACK 90VU, OPEN ACCESS
DOOR 214AZ
CHECK THAT THE TRU FAN IS OPERATIVE
11. ON PANEL 29VU
RELEASE PUSHBUTTON SWITCH P/BSW-MAIN ELEC
PWR/TRU
- ON AND ARROW LEGENDS GO OFF
- VERIFY THAT THE TWO ARROW LEGENDS OF BAT
CAUTION LIGHT COME ON.
005

________
CLOSE-UP
REF. FIG. 243181-OPT-00100
PRESS DC GEN 1 AND DC GEN 2 PUSHBUTTON
SWITCH
- VERIFY THAT ALL CAUTION LIGHTS ARE OFF

006

______________________________________
SHUT
DOWN OF ENGINE GROUND IDLE RUN-UP
SEE JOB INSTRUCTION CARD
720000-ERU-10030
*****

AH

E N D

O F

T E X T

*****

24-31-81
OPT 10000-001
2-400 PAGE
4
DEC 01/14

24-31-81
5

AH

CONTROLS AND INDICATING

OPT 10000-001
DEC14

24-31-81
OPT 10000-001

2-400

PAGE
5
DEC 01/14

24-31-81

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT

OPT 10000-002
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
: 214AZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
MECHANIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC
JIC

: ENGINE START (PROPELLER


BRAKE RELEASED) USING
DC GROUND POWER UNIT
: PRINCIPLE OF CDS USE
(DISPLAY UNITS
EXPLORATION)

AH

72-00-00-ERU-10030
31-63-00-PRO-10000

24-31-81
OPT 10000-002
2-400 PAGE
1
DEC 01/14

24-31-81

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT

001

OPT 10000-002
2

DEC14

____
NOTE
THIS JOB CARD INSTRUCTION WILL BE CARRIED OUT
WITH ENGINE RUNNING OR WITH AC WILD FREQUENCY
EXTERNAL PWR.
FOR EXTERNAL POWER PROCEDURE, USE JOB
INSTRUCTION CARD 243181-OPT-10005.

002

_________________________
ENGINE
GROUND IDLE RUN-UP
SEE JOB INSTRUCTION CARD
720000-ERU-10030

003

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

004

___________
PREPARATION
REF.FIG.243181-OPT-00100
1. MAKE CERTAIN THAT THE GROUND POWER UNIT
IS NOT CONNECTED TO DC EXTERNAL POWER
RECEPTACLE (ON PANEL 5002VU) AND THE
ACCESS DOOR 114BR IS CLOSED.
2. ON PANEL 29VU (B)
RELEASE DC GEN 1 PUSHBUTTON SWITCH
AND DC GEN 2 PUSHBUTTON SWITCHES.

*** CONTINUED ***


AH

24-31-81
OPT 10000-002
2-400 PAGE
2
DEC 01/14

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT

005

24-31-81

OPT 10000-002
3

DEC14

________________
OPERATIONAL
TEST
REF. FIG. 243181-OPT-00100
1. CHECK THAT:
A. ON PANEL 29VU:
- OFF LEGENDS OF DC GEN 1 AND 2 CAUTION
LIGHTS ARE ON
- ARROW LEGENDS OF BAT TIE CAUTION LIGHT
ARE ON
- BUS OFF FOR AC BUS 1 AND 2 CAUTION
LIGHTS ARE ON
- INV FAULT FOR INV 2 CAUTION LIGHT IS
ON
- DC BUS OFF CAUTION LIGHTS FOR DC BUS
1 AND 2 COME ON
- SHED LEGEND OF DC SVCE/UTLY BUS
PUSHBUTTON SWITCH IS ON
B. ON MFD UPPER WINDOW, IN SD ELEC PAGE,
THE FOLLOWING ITEMS ARE DISPLAYED:
- WHITE DC GEN 1 AND DC GEN 2 SYMBOLS
- AMBER ARROW SYMBOL ON EMER BAT
- AMBER ARROW SYMBOL ON MAIN BAT
- AMBER AC BUS 1 OFF SYMBOL
- AMBER AC BUS 2 OFF SYMBOL
- AMBER INV 2 FAULT SYMBOL
- AMBER DC BUS 1 OFF SYMBOL
- AMBER DC BUS 2 OFF SYMBOL
- SHED LEGENDS ABOVE UTLY BUS 1 AND
UTLY BUS 2 SYMBOLS
- GREEN EMER BUS SYMBOL
- GREEN ESS BUS SYMBOL
- GREEN AC STBY BUS SYMBOL
ON EWD, IN ALERT WINDOW, THE FOLLOWING
ITEMS ARE DISPLAYED:
- ELEC DC GEN 1 + 2 MESSAGE
- DUAL DC LOSS ASSOCIATED PROCEDURES
2. ON PANEL 29VU:
*** CONTINUED ***
AH

24-31-81
OPT 10000-002
2-400 PAGE
3
DEC 01/14

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT

24-31-81

OPT 10000-002
4

DEC14

A. PRESS TRU PUSHBUTTON SWITCH


B. VERIFY THAT:
- ON AND ARROW LEGENDS OF TRU
PUSHBUTTON COME ON
- THE TWO ARROW LEGENDS OF BAT TIE
CAUTION LIGHT GO OFF
C. CHECK THAT UNDV LEGEND OF OVRD/UNDV
PUSHBUTTON SWITCH IS STILL OFF
D. ON MFD UPPER WINDOW, IN SD ELEC PAGE,
- RECTANGLE OF TRU ITEM IS DISPLAYED
IN BLUE
- CIRCLES INSIDE TRU ITEM IS DISPLAYED
IN GREEN
- AMBER ARROW ON EMER BAT ITEM IS NOT
DISPLAYED
- AMBER ARROW ON MAIN BAT ITEM IS NOT
DISPLAYED
3. ON PANEL 129VU:
OPEN, SAFETY AND TAG THE FOLLOWING
CIRCUIT BREAKERS:
11PA DC ESS/STBY BUS ON HMBB/GEN PWR SPLY
4XA INV 1 HOT MAIN BAT BUS
4. ON PANEL 130VU:
OPEN, SAFETY AND TAG THE FOLLOWING
CIRCUIT BREAKERS:
64PA DC EMER & STBY BUS ON HEBB/GENERAL
PWR SPLY
7XA INV 1 ON HOT EMER BAT BUS
5. ON PANEL 29VU:
VERIFY THAT BATTERY AMMETER SHOWS A ZERO
LOAD EITHER IF BAT SEL SWITCH IS
PLACED IN EMER OR IN MAIN POSITION
6. ON MFD UPPER WINDOW, IN SD ELEC PAGE,
VERIFY THAT:
- GREEN EMER BUS SYMBOL IS DISPLAYED
- GREEN ESS BUS SYMBOL IS DISPLAYED
- GREEN AC STBY BUS SYMBOL IS DISPLAYED
*** CONTINUED ***
AH

24-31-81
OPT 10000-002
2-400 PAGE
4
DEC 01/14

24-31-81

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT

OPT 10000-002
5

DEC14

7. ON PANEL 129VU:
CLOSE THE FOLLOWING CIRCUIT BREAKERS:
11PA
4XA
8. ON PANEL 130VU:
CLOSE THE FOLLOWING CIRCUIT BREAKERS:
64PA
7XA
NOTE: ON ELECTRONICS RACK 90VU, OPEN ACCESS
DOOR 214AZ
CHECK THAT THE TRU FAN IS OPERATING
9. ON PANEL 29VU:
RELEASE TRU PUSHBUTTON SWITCH
- ON AND ARROW LEGENDS GO OFF
- VERIFY THAT THE TWO ARROW LEGENDS OF BAT
TIE CAUTION LIGHT COME ON.
ON MFD UPPER WINDOW, IN SD ELEC PAGE,
VERIFY THAT:
- RECTANGLE OF TRU ITEM IS DISPLAYED
IN GREEN
- CIRCLES INSIDE TRU ITEM IS DISPLAYED
IN WHITE
- AMBER ARROW ITEM IS DISPLAYED ON
EMER BAT
- AMBER ARROW ITEM IS DISPLAYED ON
MAIN BAT
006

________
CLOSE-UP
REF. FIG. 243181-OPT-00100
PRESS DC GEN 1 AND DC GEN 2 PUSHBUTTON
SWITCH. VERIFY THE FOLLOWING:
- ALL PREVIOUSLY RELATED CAUTION LIGHTS ARE
OFF
- ELEC DC GEN 1 + 2 MESSAGE AND DUAL DC
LOSS ASSOCIATED PROCEDURES ARE NO LONGER
DISPLAYED ON EWD
*** CONTINUED ***
AH

24-31-81
OPT 10000-002
2-400 PAGE
5
DEC 01/14

24-31-81

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT

OPT 10000-002
6

DEC14

- ALL SYMBOLS ON MFD ARE GREEN


007

______________________________________
SHUT
DOWN OF ENGINE GROUND IDLE RUN-UP
SEE JOB INSTRUCTION CARD
720000-ERU-10030
*****

AH

E N D

O F

T E X T

*****

24-31-81
OPT 10000-002
2-400 PAGE
6
DEC 01/14

24-31-81
7

AH

CONTROLS AND INDICATING

OPT 10000-002
DEC14

24-31-81
OPT 10000-002

2-400

PAGE
7
DEC 01/14

24-31-81

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT
(WITH AC EXT PWR SPLY)

OPT 10005-002
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
MECHANIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: AC WILD FREQUENCY
EXTERNAL POWER SUPPLY

AH

24-41-00-EAD-10000

24-31-81
OPT 10005-002
2-400 PAGE
1
DEC 01/14

24-31-81

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT
(WITH AC EXT PWR SPLY)

001

OPT 10005-002
2

DEC14

____
NOTE
THIS JOB CARD INSTRUCTION WILL BE PERFORMED
WITH ENGINES RUNNING OR WITH AC WILD FREQUENCY
EXTERNAL PWR.
TO PERFORM THIS OPERATIONAL TEST WITH ENGINES
RUNNING, SEE JOB INSTRUCTION CARD
243181-OPT-10000.

002

ENERGIZATION OF AIRCRAFT AC WILD FREQUENCY


__________________________________________
NETWORK
_______
SEE JOB INSTRUCTION CARD
244100-EAD-10000

003

________________
OPERATIONAL
TEST
REF.FIG.243181-OPT-00100
1. ON PANEL 29VU (B) CHECK THAT:
- ARROW LEGENDS OF BAT TIE CAUTION LIGHT
ARE ON
- BUS OFF FOR AC BUS 1 CAUTION LIGHTS
IS ON
- BUS OFF FOR AC BUS 2 AND INV FAULT FOR
INV 2 CAUTION LIGHTS ARE ON
- DC BUS OFF CAUTION LIGHTS FOR DC BUS 1
AND 2 COME ON
- SHED LEGEND OF DC SVCE/UTLY BUS PUSHBUTTON
SWITCH IS ON
2. VERIFY THAT THE FOLLOWING SYSTEMS ARE
SUPPLIED:
- VHF 1
- FUEL QTY INDICATOR
- FLAPS POSITION INDICATOR
3. ON PANEL 29VU
A. PRESS TRU PUSHBUTTON SWITCH
- ON AND ARROW LEGENDS COME ON
B. VERIFY THAT THE TWO ARROW LEGENDS OF BAT
*** CONTINUED ***
AH

24-31-81
OPT 10005-002
2-400 PAGE
2
DEC 01/14

24-31-81

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT
(WITH AC EXT PWR SPLY)

OPT 10005-002
3

DEC14

TIE CAUTION LIGHT GO OFF


C. CHECK THAT UNDV LEGEND OF OVRD/UNDV PUSHBUTTON SWITCH IS STILL OFF
4. ON PANEL 129VU (A)
OPEN SAFETY CLIPS AND TAGS THE FOLLOWING
CIRCUIT BREAKERS:
11PA DC ESS/STBY BUS ON HMBB/GEN PWR
SPLY
4XA INV 1 HOT MAIN BAT BUS
5. ON PANEL 130VU (A)
OPEN SAFETY CLIPS AND TAGS THE FOLLOWING
CIRCUIT BREAKERS:
64PA DC EMER & STBY BUS ON HEBB/GENERAL
PWR SPLY
7XA INV 1 ON HOT EMER BAT BUS
6. ON PANEL 29VU
VERIFY THAT BATTERY AMMETER SHOWS ZERO
LOAD EITHER IF BAT SEL SWITCH IS PLACED IN
EMER OR IN MAIN POSITION
7. VERIFY THAT THE FOLLOWING SYSTEMS ARE
STILL SUPPLIED:
- VHF 1
- FUEL QTY INDICATOR
- FLAPS POSITION INDICATOR
8. ON PANEL 29VU
CHECK THAT INV FAULT 1 LEGEND OF CAUTION
LIGHT IS OFF
9. ON PANEL 129VU
REMOVE SAFETY CLIPS AND TAGS AND CLOSE THE
FOLLOWING CIRCUIT BREAKERS:
11PA
4XA
10. ON PANEL 130VU
REMOVE SAFETY CLIPS AND TAGS AND CLOSE THE
*** CONTINUED ***
AH

24-31-81
OPT 10005-002
2-400 PAGE
3
DEC 01/14

24-31-81

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT
(WITH AC EXT PWR SPLY)

OPT 10005-002
4

DEC14

FOLLOWING CIRCUIT BREAKERS:


64PA
7XA
NOTE: ON ELECTRONICS RACK 90VU, OPEN ACCESS
DOOR 214AZ
CHECK THAT THE TRU FAN IS OPERATIVE
11. ON PANEL 29VU
RELEASE PUSHBUTTON SWITCH P/BSW-MAIN ELEC
PWR/TRU
- ON AND ARROW LEGENDS GO OFF
- VERIFY THAT THE TWO ARROW LEGENDS OF BAT
CAUTION LIGHT COME ON.
004

DE-ENERGIZATION OF AIRCRAFT AC WILD FREQUENCY


_____________________________________________
NETWORK
_______
SEE JOB INSTRUCTION CARD
244100-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-31-81
OPT 10005-002
2-400 PAGE
4
DEC 01/14

24-31-81
5

AH

CONTROLS AND INDICATING

OPT 10005-002
DEC14

24-31-81
OPT 10005-002

2-400

PAGE
5
DEC 01/14

24-31-81

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT
(WITH AC EXT PWR SPLY)

OPT 10005-003
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
MECHANIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC
JIC

: AC WILD FREQUENCY
EXTERNAL POWER SUPPLY
: PRINCIPLE OF CDS USE
(DISPLAY UNITS
EXPLORATION)

AH

24-41-00-EAD-10000
31-63-00-PRO-10000

24-31-81
OPT 10005-003
2-400 PAGE
1
DEC 01/14

24-31-81

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT
(WITH AC EXT PWR SPLY)

001

OPT 10005-003
2

DEC14

____
NOTE
THIS JOB CARD INSTRUCTION WILL BE PERFORMED
WITH ENGINES RUNNING OR WITH AC WILD FREQUENCY
EXTERNAL PWR.
TO PERFORM THIS OPERATIONAL TEST WITH ENGINES
RUNNING, SEE JOB INSTRUCTION CARD
243181-OPT-10000.

002

ENERGIZATION OF AIRCRAFT AC WILD FREQUENCY


__________________________________________
NETWORK
_______
SEE JOB INSTRUCTION CARD
244100-EAD-10000

003

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

004

________________
OPERATIONAL
TEST
REF. FIG. 243181-OPT-00100
1. CHECK THAT:
A. ON PANEL 29VU:
- ARROW LEGENDS OF BAT TIE CAUTION LIGHT
ARE ON
- BUS OFF FOR AC BUS 1 AND 2 CAUTION
LIGHTS ARE ON
- INV FAULT FOR INV 2 CAUTION LIGHT IS
ON
*** CONTINUED ***
AH

24-31-81
OPT 10005-003
2-400 PAGE
2
DEC 01/14

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT
(WITH AC EXT PWR SPLY)

24-31-81

OPT 10005-003
3

DEC14

- DC BUS OFF CAUTION LIGHTS FOR DC BUS


1 AND 2 COME ON
- SHED LEGEND OF DC SVCE/UTLY BUS
PUSHBUTTON SWITCH IS ON
B. ON MFD UPPER WINDOW, IN SD ELEC PAGE,
THE FOLLOWING ITEMS ARE DISPLAYED:
- AMBER ARROW SYMBOL ON
EMER BAT
- AMBER ARROW SYMBOL ON
MAIN BAT
- AMBER AC BUS 1 OFF SYMBOL
- AMBER AC BUS 2 OFF SYMBOL
- AMBER INV 2 FAULT SYMBOL
- AMBER DC BUS 1 OFF SYMBOL
- AMBER DC BUS 2 OFF SYMBOL
- SHED LEGENDS ABOVE UTLY BUS 1 AND
UTLY BUS 2 SYMBOLS
- GREEN EMER BUS SYMBOL
- GREEN ESS BUS SYMBOL
- GREEN AC STBY BUS SYMBOL
2. ON PANEL 29VU:
A. PRESS TRU PUSHBUTTON SWITCH
B. VERIFY THAT:
- ON AND ARROW LEGENDS OF TRU
PUSHBUTTON COME ON
- THE TWO ARROW LEGENDS OF BAT TIE
CAUTION LIGHT GO OFF
C. CHECK THAT UNDV LEGEND OF OVRD/UNDV
PUSHBUTTON SWITCH IS STILL OFF
D. ON MFD UPPER WINDOW, IN SD ELEC PAGE,
- RECTANGLE OF TRU ITEM IS DISPLAYED
IN BLUE
- CIRCLES INSIDE TRU ITEM IS DISPLAYED
IN GREEN
- AMBER ARROW ON EMER BAT ITEM IS NOT
DISPLAYED
- AMBER ARROW ON MAIN BAT ITEM IS NOT
DISPLAYED
*** CONTINUED ***
AH

24-31-81
OPT 10005-003
2-400 PAGE
3
DEC 01/14

24-31-81

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT
(WITH AC EXT PWR SPLY)

OPT 10005-003
4

DEC14

3. ON PANEL 129VU:
OPEN, SAFETY AND TAG THE FOLLOWING
CIRCUIT BREAKERS:
11PA DC ESS/STBY BUS ON HMBB/GEN PWR SPLY
4XA INV 1 HOT MAIN BAT BUS
4. ON PANEL 130VU:
OPEN, SAFETY AND TAG THE FOLLOWING
CIRCUIT BREAKERS:
64PA DC EMER & STBY BUS ON HEBB/GENERAL
PWR SPLY
7XA INV 1 ON HOT EMER BAT BUS
5. ON PANEL 29VU:
VERIFY THAT BATTERY AMMETER SHOWS A ZERO
LOAD EITHER IF BAT SEL SWITCH IS
PLACED IN EMER OR IN MAIN POSITION
6. ON MFD UPPER WINDOW, IN SD ELEC PAGE,
VERIFY THAT:
- GREEN EMER BUS SYMBOL IS DISPLAYED
- GREEN ESS BUS SYMBOL IS DISPLAYED
- GREEN AC STBY BUS SYMBOL IS DISPLAYED
7. ON PANEL 129VU:
CLOSE THE FOLLOWING CIRCUIT BREAKERS:
11PA
4XA
8. ON PANEL 130VU:
CLOSE THE FOLLOWING CIRCUIT BREAKERS:
64PA
7XA
NOTE: ON ELECTRONICS RACK 90VU, OPEN ACCESS
DOOR 214AZ
CHECK THAT THE TRU FAN IS OPERATING
9. ON PANEL 29VU:
RELEASE TRU PUSHBUTTON SWITCH
- ON AND ARROW LEGENDS GO OFF
*** CONTINUED ***
AH

24-31-81
OPT 10005-003
2-400 PAGE
4
DEC 01/14

24-31-81

OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT
(WITH AC EXT PWR SPLY)

OPT 10005-003
5

DEC14

- VERIFY THAT THE TWO ARROW LEGENDS OF BAT


TIE CAUTION LIGHT COME ON.
ON MFD UPPER WINDOW, IN SD ELEC PAGE,
VERIFY THAT:
- RECTANGLE OF TRU ITEM IS DISPLAYED
IN GREEN
- CIRCLES INSIDE TRU ITEM IS DISPLAYED
IN WHITE
- AMBER ARROW ITEM IS DISPLAYED ON
EMER BAT
- AMBER ARROW ITEM IS DISPLAYED ON
MAIN BAT
005

DE-ENERGIZATION OF AIRCRAFT AC WILD FREQUENCY


_____________________________________________
NETWORK
_______
SEE JOB INSTRUCTION CARD
244100-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-31-81
OPT 10005-003
2-400 PAGE
5
DEC 01/14

24-31-81
6

AH

CONTROLS AND INDICATING

OPT 10005-003
DEC14

24-31-81
OPT 10005-003

2-400

PAGE
6
DEC 01/14

24-31-81

REMOVAL AND INSTALLATION


OF T R U

RAI 10000-002
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 212
214
222
: 212TZ 212VZ 214AZ 222AZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

___
MEN

_________
MAN-HOURS
01

ELAPSED TIME

SPARE

: 01 T R U

24-31-80

: OPERATIONAL TEST OF TRU


AND ASSOCIATED CIRCUIT

24-31-81-OPT-10000

PUBLICATION
___________
JIC

AH

24-31-81
RAI 10000-002
2-400 PAGE
1
DEC 01/14

24-31-81

REMOVAL AND INSTALLATION


OF T R U

001

RAI 10000-002
2

DEC14

___________
PREPARATION
REF. FIG. 240000-RAI-00100
NOTE:MAKE CERTAIN THAT THE GROUND POWER UNIT
IS NOT CONNECTED TO THE DC AND AC EXTERNAL
POWER.
1. ON PANEL 29VU:
- VERIFY THAT BAT SELECTOR SWITCH IS IN
OFF POSITION.
- DISPLAY A WARNING NOTICE PROHIBITING POWER
SUPPLY BY BATTERIES.
2. ON ELECTRICS RACK 90VU:
- REMOVE ACCESS PANELS:214AZ,222AZ.
3. ON AC/DC POWER CENTER 120VU (IF NECESSARY):
- REMOVE ACCESS PANELS 212VZ,212TZ.

002

_______
REMOVAL
REF.FIG.243181-RAI-00100
1. UNPLUG ELECTRICAL CONNECTOR (3).
2. PUT BLANKING CAP ON ELECTRICAL CONNECTOR.
3. REMOVE COVERS (5)(REMOVE SCREWS (4) IF
COVERS ARE ATTACHED BY SCREWS).
4. REMOVE NUTS (6 AND 7) AND WASHERS (8) TO
DISCONNECT TERMINAL LUGS (9).
5. MARK AND DISCONNECT TERMINAL LUGS.
6. REMOVE SCREW OR NUT (10) AND WASHER (11) TO
DISCONNECT CHASSIS GROUND TERMINAL LUG (12).
7. MARK AND DISCONNECT TERMINAL LUG.
*** CONTINUED ***
AH

24-31-81
RAI 10000-002
2-400 PAGE
2
DEC 01/14

24-31-81

REMOVAL AND INSTALLATION


OF T R U

RAI 10000-002
3

DEC14

8. REMOVE SCREWS (2) AND WASHERS (1) RETAINING


TRANSFORMER RECTIFIER UNIT (13).
9. REMOVE TRANSFORMER.
NOTE: PROTECT COMPONENT INTERFACE AND OR
COMPONENT ADJACENT AREA.
003

____________
INSTALLATION
REF.FIG.243181-RAI-00100
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA.
2. INSTALL TRANSFORMER RECTIFIER UNIT (13).
3. INSTALL WASHERS (1) AND SCREWS (2). TIGHTEN
SCREWS.
4. INSTALL TERMINAL LUGS (9), WASHERS (8) AND
NUTS (6 AND 7), TIGHTEN AND MARK THEM WITH
RED VARNISH.
5. INSTALL CHASSIS GROUND TERMINAL LUG (12),
WASHER (11) AND SCREW OR NUT (10), TIGHTEN
AND MARK IT MARK WITH RED VARNISH.
6. INSTALL COVERS (5) (INSTALL AND TIGHTEN
SCREWS (4) IF COVERS ARE ATTACHED BY SCREWS)
7. REMOVE BLANKING CAP FROM ELECTRICAL
CONNECTOR (3).
8. PLUG IN ELECTRICAL CONNECTOR.

004

________
CLOSE
UP
1. ON PANEL 29VU:
- REMOVE WARNING NOTICE.
2. CLOSE ALL ACCESS PANELS PREVIOUSLY OPENED.
*** CONTINUED ***
AH

24-31-81
RAI 10000-002
2-400 PAGE
3
DEC 01/14

24-31-81

REMOVAL AND INSTALLATION


OF T R U

005

RAI 10000-002
4

DEC14

______________________________________________
OPERATIONAL
TEST OF TRU AND ASSOCIATED CIRCUIT
SEE JOB INSTRUCTION CARD
243181-OPT-10000
*****

AH

E N D

O F

T E X T

*****

24-31-81
RAI 10000-002
2-400 PAGE
4
DEC 01/14

24-31-81
5

AH

CONTROLS AND INDICATING

RAI 10000-002
DEC14

24-31-81
RAI 10000-002

2-400

PAGE
5
DEC 01/14

24-31-81
6

AH

REMOVAL AND INSTALLATION


OF TRU

RAI 10000-002
DEC14

24-31-81
RAI 10000-002

2-400

PAGE
6
DEC 01/14

24-31-85

CHECK OF BATTERY VOLTAGE

CHK 10000-002
1

DEC14

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC

: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

24-46-00-EAD-10000

24-31-85
CHK 10000-002
2-400 PAGE
1
DEC 01/14

24-31-85

CHECK OF BATTERY VOLTAGE

CHK 10000-002
2

001

DEC14

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

002

________________________
CHECK
OF BATTERY VOLTAGE
REF.FIG.243110-CHK-00130
1. ON PANEL 101VU
A. PLACE ELEC IND SELECTOR SWITCH TO MAIN
BAT POSITION
B. VERIFY THAT THE VOLTAGE ON DC VOLTMETER
IS 28V
2. ON PANEL 29VU
RELEASE MAIN BAT CHG PUSHBUTTON SWITCH
-OFF LEGEND COMES ON
3. ON PANEL 101VU
VERIFY THAT THE VOLTAGE IS AT LEAST 24V
4. ON THE SAME PANEL
A. PLACE ELEC IND SELECTOR SWITCH TO EMER
BAT POSITION
B. VERIFY THAT THE VOLTAGE IS 28V
5. ON PANEL 29VU
RELEASE EMER BAT CHG PUSHBUTTON SWITCH
- OFF LEGEND COMES ON
6. ON PANEL 101VU
VERIFY THAT THE VOLTAGE IS AT LEAST 24V
7. ON PANEL 29VU
PRESS MAIN AND EMER BAT CHG PUSHBUTTON
SWITCHES
- OFF LEGENDS GO OFF

*** CONTINUED ***


AH

24-31-85
CHK 10000-002
2-400 PAGE
2
DEC 01/14

24-31-85

CHECK OF BATTERY VOLTAGE

CHK 10000-002
3

003

DEC14

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-31-85
CHK 10000-002
2-400 PAGE
3
DEC 01/14

24-31-85
4

AH

CONTROLS AND INDICATING

CHK 10000-002
DEC14

24-31-85
CHK 10000-002

2-400

PAGE
4
DEC 01/14

24-31-85

CHECK OF BATTERY VOLTAGE

CHK 10000-003
1

DEC14

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC

: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

24-46-00-EAD-10000

24-31-85
CHK 10000-003
2-400 PAGE
1
DEC 01/14

CHECK OF BATTERY VOLTAGE

24-31-85

CHK 10000-003
2

001

DEC14

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

002

________________________
CHECK
OF BATTERY VOLTAGE
REF.FIG.243110-CHK-00130
1. ON PANEL 101VU
A. PLACE ELEC IND SELECTOR SWITCH TO MAIN
BAT POSITION.
B. VERIFY THAT THE VOLTAGE ON DC VOLTMETER
AND ON MFD UPPER WINDOW, IN ELEC SD PAGE,
IS 28V.
2. ON PANEL 29VU
RELEASE MAIN BAT CHG PUSHBUTTON SWITCH
- OFF LEGEND COMES ON
- ON MFD UPPER WINDOW, IN ELEC SD PAGE,
CHG OFF SYMBOL IS DISPLAYED FOR MAIN
BATTERY CHARGER.
3. VERIFY ON DC VOLTMETER (PANEL 101VU) AND ON
MFD UPPER WINDOW, IN ELEC SD PAGE THAT THE
VOLTAGE IS AT LEAST 24V.
4. A. ON PANEL 101VU, PLACE ELEC IND SELECTOR
SWITCH TO EMER BAT POSITION.
B. VERIFY ON DC VOLTMETER (PANEL 101VU) AND
ON MFD UPPER WINDOW, IN ELEC SD PAGE THAT
THE VOLTAGE IS 28V.
5. ON PANEL 29VU
RELEASE EMER BAT CHG PUSHBUTTON SWITCH
- OFF LEGEND COMES ON
- ON MFD UPPER WINDOW, IN ELEC SD PAGE,
CHG OFF SYMBOL IS DISPLAYED FOR
EMERGENCY BATTERY CHARGER.
*** CONTINUED ***
AH

24-31-85
CHK 10000-003
2-400 PAGE
2
DEC 01/14

24-31-85

CHECK OF BATTERY VOLTAGE

CHK 10000-003
3

DEC14

6. VERIFY ON DC VOLTMETER (PANEL 101VU) AND ON


MFD UPPER WINDOW, IN ELEC SD PAGE THAT THE
VOLTAGE IS AT LEAST 24V.
7. ON PANEL 29VU
PRESS MAIN AND EMER BAT CHG PUSHBUTTON
SWITCHES
- OFF LEGENDS GO OFF
- ON MFD UPPER WINDOW, IN ELEC SD PAGE CHG
SYMBOL IS DISPLAYED FOR EMERGENCY AND MAIN
BATTERY CHARGER.
003

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-31-85
CHK 10000-003
2-400 PAGE
3
DEC 01/14

24-31-85
4

AH

CONTROLS AND INDICATING

CHK 10000-003
DEC14

24-31-85
CHK 10000-003

2-400

PAGE
4
DEC 01/14

24-31-85

MAIN BATTERY REMOVAL AND


INSTALLATION

RAI 10010-003
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 213
214
: 213AZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC
MECHANIC

___
MEN

_________
MAN-HOURS
01
01

ELAPSED TIME

SPARE

: 01 BATTERY 21PA

243110-01

EXPENDABLE

: 02 O-RING

212410-01

BULK MATERIAL : LOCKWIRE


PUBLICATION
___________
JIC
JIC

: POWER SUPPLY FROM


BATTERY
: ADJUSTMENT OF FDAU TIME
BASE

AH

24-31-00-EAD-10000
31-31-81-ADJ-10000

24-31-85
RAI 10010-003
2-400 PAGE
1
DEC 01/14

24-31-85

MAIN BATTERY REMOVAL AND


INSTALLATION

001

RAI 10010-003
2

DEC14

___________
PREPARATION
REF. FIG. 243115-RAI-00100
REF. FIG. 243115-RAI-00110
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO DC EXTERNAL POWER
RECEPTACLE (ON PANEL 5002VU) AND THE
ACCESS DOOR 114BR IS CLOSED
2. ON PANEL 29VU MAKE CERTAIN THAT:
BAT SELECTOR SWITCH 7PA IS IN OFF POSITION
3. ON PANEL 27VU MAKE CERTAIN THAT:
ENG START SELECTOR SWITCH 13KG IS IN OFF
POSITION
4. DISPLAY A WARNING NOTICE ON PANELS 27VU AND
29VU, PROHIBITING POWER SUPPLY TO THE SYSTEM
AND ENGINE STARTING
5. ON L ELECTRONICS RACK 80VU
OPEN ACCESS DOOR 213AZ.

002

________________________________________
DE-ENERGIZATION
OF AIR EXTRACTION SYSTEM
CAUTION : DISPLAY WARNING NOTICE INDICATING
THAT :
DURING MAINTENANCE OPERATIONS ON AIR
EXTRACTION SYSTEM, INSTRUMENT PANELS
AND ELECTRONICS RACKS ARE NOT
VENTILATED.
OPEN, SAFETY AND TAG THE FOLLOWING CIRCUIT
BREAKERS :
A. ON CIRCUIT BREAKER PANEL 121VU :
1HR AVIONICS VENT/IND
5HR AVIONICS VENT/VALVES
24HR AVIONICS VENT/EXTRACT FAN CTL
*** CONTINUED ***
AH

24-31-85
RAI 10010-003
2-400 PAGE
2
DEC 01/14

24-31-85

MAIN BATTERY REMOVAL AND


INSTALLATION

RAI 10010-003
3

DEC14

B. ON PANEL 124VU :
4HR PWR SUPLY ON PRIM DC BUS 2/EXTRACT FAN
C. ON PANEL 127VU :
3HR PWR SUPLY ON PRIM DC BUS 1/EXTRACT FAN
003

_______
REMOVAL
REF. FIG. 243115-RAI-00110
1. UNPLUG THE OVERHEAT DETECTION ELECTRICAL
CONNECTOR (5)
2. CUT AND REMOVE LOCKWIRE, LOOSE KNURLED
KNOB (7) AND UNPLUG THE BATTERY ELECTRICAL
CONNECTOR (8)
3. DISCONNECT THE TWO BATTERY VENTILATION
DUCTS (4)
4. UNLOCK AND DISENGAGE THE TWO LATCHES (10)
5. PULL, OUT OF THE ELECTRONIC RACK, THE
MAIN BATTERY (9) AND ITS TRAY (6) USING THE
SUPPORT HANDLE.
6. LOOSE THE LATCHES (11) AND REMOVE THE
STRAP (12) KEEPING THE BATTERY (9).
NOTE: REMOVE THE BATTERY FROM ITS SUPPORT
ONLY WHEN THE HANDLING IS FINISH
7. REMOVE THE BATTERY (9).

004

____________
INSTALLATION
REF. FIG. 243115-RAI-00110
1. CLEAN AND INSPECT BATTERY (9) INTERFACE
AND/OR COMPONENT ADJACENT AREA.
*** CONTINUED ***
AH

24-31-85
RAI 10010-003
2-400 PAGE
3
DEC 01/14

24-31-85

MAIN BATTERY REMOVAL AND


INSTALLATION

RAI 10010-003
4

DEC14

2. POSITION BATTERY INTO ITS TRAY (6).


3. SECURE THE BATTERY IN ITS TRAY WITH
STRAP (12). CLAMP THE LATCHES (11).
4. INSTALL THE BATTERY/TRAY ASSY INTO THE
ELECTRONIC RACK.
5. MAKE SURE THAT PINS (13) ARE ENGAGED INTO
HOUSING (14) AND TIGHTEN THE LATCHES (10).
6. MAKE SURE THAT O-RING (15) ARE IN GOOD
CONDITION, REPLACE THEM IN CONTRARY CASE.
7. CONNECT THE TWO BATTERY VENTILATION
DUCTS (4).
8. PLUG THE BATTERY ELECTRICAL CONNECTOR (8)
BY MEANS OF KNURLED KNOB (7) AND SAFETY IT
WITH LOCKWIRE.
9. PLUG THE OVERHEAT DETECTION ELECTRICAL
CONNECTOR (5).
005

_____________________________________
ENERGIZATION
OF AIR EXTRACTION SYSTEM
REMOVE SAFETY CLIPS AND TAGS AND CLOSE CIRCUIT
BREAKERS PREVIOUSLY OPENED.

006

________
CLOSE-UP
REF. FIG. 243115-RAI-00110
1. ON L ELECTRONIC RACK 80VU
CLOSE ACCESS DOOR 213AZ.
2. REMOVE THE WARNING NOTICES.

007

___________________________
POWER
SUPPLY FROM BATTERIES
SEE JOB INSTRUCTION CARD
243100-EAD-10000
*** CONTINUED ***
AH

24-31-85
RAI 10010-003
2-400 PAGE
4
DEC 01/14

24-31-85

MAIN BATTERY REMOVAL AND


INSTALLATION

008

RAI 10010-003
5

DEC14

____________________________
ADJUSTMENT
OF FDAU TIME BASE
SEE JOB INSTRUCTION CARD
313181-ADJ-10000

009

________________
OPERATIONAL
TEST
THIS TEXT IS NOT APPLICABLE
*****

AH

E N D

O F

T E X T

*****

24-31-85
RAI 10010-003
2-400 PAGE
5
DEC 01/14

24-31-85
6

AH

CONTROLS AND INDICATING

RAI 10010-003
DEC14

24-31-85
RAI 10010-003

2-400

PAGE
6
DEC 01/14

24-31-85
7

AH

MAIN BATTERY
REMOVAL AND INSTALLATION

RAI 10010-003
DEC14

24-31-85
RAI 10010-003

2-400

PAGE
7
DEC 01/14

24-31-85

MAIN BATTERY REMOVAL AND


INSTALLATION

RAI 10010-004
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 213
214
: 213AZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELECTRIC
MECHANIC

_________
MAN-HOURS
01
01

ELAPSED TIME

SPARE

: 01 BATTERY 21PA

243110-01

EXPENDABLE

: 02 O-RING

212410-01

BULK MATERIAL : LOCKWIRE


PUBLICATION
___________
JIC

: POWER SUPPLY FROM


BATTERY

AH

24-31-00-EAD-10000

24-31-85
RAI 10010-004
2-400 PAGE
1
DEC 01/14

24-31-85

MAIN BATTERY REMOVAL AND


INSTALLATION

001

RAI 10010-004
2

DEC14

___________
PREPARATION
REF. FIG. 243115-RAI-00100
REF. FIG. 243115-RAI-00110
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO DC EXTERNAL POWER
RECEPTACLE (ON PANEL 5002VU) AND THE
ACCESS DOOR 114BR IS CLOSED
2. ON PANEL 29VU MAKE CERTAIN THAT:
BAT SELECTOR SWITCH 7PA IS IN OFF POSITION
3. ON PANEL 27VU MAKE CERTAIN THAT:
ENG START SELECTOR SWITCH 13KG IS IN OFF
POSITION
4. DISPLAY A WARNING NOTICE ON PANELS 27VU AND
29VU, PROHIBITING POWER SUPPLY TO THE SYSTEM
AND ENGINE STARTING
5. ON L ELECTRONICS RACK 80VU
OPEN ACCESS DOOR 213AZ.

002

________________________________________
DE-ENERGIZATION
OF AIR EXTRACTION SYSTEM
CAUTION : DISPLAY WARNING NOTICE INDICATING
THAT :
DURING MAINTENANCE OPERATIONS ON AIR
EXTRACTION SYSTEM, INSTRUMENT PANELS
AND ELECTRONICS RACKS ARE NOT
VENTILATED.
OPEN, SAFETY AND TAG THE FOLLOWING CIRCUIT
BREAKERS :
A. ON CIRCUIT BREAKER PANEL 121VU :
1HR AVIONICS VENT/IND
5HR AVIONICS VENT/VALVES
24HR AVIONICS VENT/EXTRACT FAN CTL
*** CONTINUED ***
AH

24-31-85
RAI 10010-004
2-400 PAGE
2
DEC 01/14

24-31-85

MAIN BATTERY REMOVAL AND


INSTALLATION

RAI 10010-004
3

DEC14

B. ON PANEL 124VU :
4HR PWR SUPLY ON PRIM DC BUS 2/EXTRACT FAN
C. ON PANEL 127VU :
3HR PWR SUPLY ON PRIM DC BUS 1/EXTRACT FAN
003

_______
REMOVAL
REF. FIG. 243115-RAI-00110
1. UNPLUG THE OVERHEAT DETECTION ELECTRICAL
CONNECTOR (5)
2. CUT AND REMOVE LOCKWIRE, LOOSE KNURLED
KNOB (7) AND UNPLUG THE BATTERY ELECTRICAL
CONNECTOR (8)
3. DISCONNECT THE TWO BATTERY VENTILATION
DUCTS (4)
4. UNLOCK AND DISENGAGE THE TWO LATCHES (10)
5. PULL, OUT OF THE ELECTRONIC RACK, THE
MAIN BATTERY (9) AND ITS TRAY (6) USING THE
SUPPORT HANDLE.
6. LOOSE THE LATCHES (11) AND REMOVE THE
STRAP (12) KEEPING THE BATTERY (9).
NOTE: REMOVE THE BATTERY FROM ITS SUPPORT
ONLY WHEN THE HANDLING IS FINISH
7. REMOVE THE BATTERY (9).

004

____________
INSTALLATION
REF. FIG. 243115-RAI-00110
1. CLEAN AND INSPECT BATTERY (9) INTERFACE
AND/OR COMPONENT ADJACENT AREA.
*** CONTINUED ***
AH

24-31-85
RAI 10010-004
2-400 PAGE
3
DEC 01/14

24-31-85

MAIN BATTERY REMOVAL AND


INSTALLATION

RAI 10010-004
4

DEC14

2. POSITION BATTERY INTO ITS TRAY (6).


3. SECURE THE BATTERY IN ITS TRAY WITH
STRAP (12). CLAMP THE LATCHES (11).
4. INSTALL THE BATTERY/TRAY ASSY INTO THE
ELECTRONIC RACK.
5. MAKE SURE THAT PINS (13) ARE ENGAGED INTO
HOUSING (14) AND TIGHTEN THE LATCHES (10).
6. MAKE SURE THAT O-RING (15) ARE IN GOOD
CONDITION, REPLACE THEM IN CONTRARY CASE.
7. CONNECT THE TWO BATTERY VENTILATION
DUCTS (4).
8. PLUG THE BATTERY ELECTRICAL CONNECTOR (8)
BY MEANS OF KNURLED KNOB (7) AND SAFETY IT
WITH LOCKWIRE.
9. PLUG THE OVERHEAT DETECTION ELECTRICAL
CONNECTOR (5).
005

_____________________________________
ENERGIZATION
OF AIR EXTRACTION SYSTEM
REMOVE SAFETY CLIPS AND TAGS AND CLOSE CIRCUIT
BREAKERS PREVIOUSLY OPENED.

006

________
CLOSE-UP
REF. FIG. 243115-RAI-00110
1. ON L ELECTRONIC RACK 80VU
CLOSE ACCESS DOOR 213AZ.
2. REMOVE THE WARNING NOTICES.

007

___________________________
POWER
SUPPLY FROM BATTERIES
SEE JOB INSTRUCTION CARD
243100-EAD-10000
*** CONTINUED ***
AH

24-31-85
RAI 10010-004
2-400 PAGE
4
DEC 01/14

24-31-85

MAIN BATTERY REMOVAL AND


INSTALLATION

008

RAI 10010-004
5

DEC14

________________
OPERATIONAL
TEST
THIS TEXT IS NOT APPLICABLE
*****

AH

E N D

O F

T E X T

*****

24-31-85
RAI 10010-004
2-400 PAGE
5
DEC 01/14

24-31-85
6

AH

CONTROLS AND INDICATING

RAI 10010-004
DEC14

24-31-85
RAI 10010-004

2-400

PAGE
6
DEC 01/14

24-31-85
7

AH

MAIN BATTERY
REMOVAL AND INSTALLATION

RAI 10010-004
DEC14

24-31-85
RAI 10010-004

2-400

PAGE
7
DEC 01/14

24-31-85

EMER BATTERY REMOVAL AND


INSTALLATION

RAI 10020-004
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 114
221
: 114CR
221AZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELECTRIC
MECHANIC
ELAPSED TIME

SPARE

: 01 BATTERY 243115

_________
MAN-HOURS
01
01

PUBLICATION
___________
JIC
JIC

: POWER SUPPLY FROM


BATTERY
: ADJUSTMENT OF FDAU TIME
BASE

AH

24-31-00-EAD-10000
31-31-81-ADJ-10000

24-31-85
RAI 10020-004
2-400 PAGE
1
DEC 01/14

24-31-85

EMER BATTERY REMOVAL AND


INSTALLATION

001

RAI 10020-004
2

DEC14

___________
PREPARATION
REF.FIG.243115-RAI-00120-001(FIG.1) AND 243115RAI-00130-001(FIG.2)
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO DC EXTERNAL POWER RECEPTACLE (ON PANEL 5002VU/FIG.1-B) AND THE ACCESS DOOR 114BR(FIG.1-A) IS CLOSED
2. ON PANEL 29VU(FIG.1-C) MAKE CERTAIN THAT:
BAT SELECTOR SWITCH 7PA IS IN OFF POSITION
3. DISPLAY A WARNING NOTICE ON PANEL 29VU PROHIBITING POWER SUPPLY TO THE SYSTEM
4. ON L ELECTRONICS RACK 80VU
OPEN ACCESS DOOR 221AZ (FIG.2-A)

002

_______
REMOVAL
REF.FIG.243115-RAI-00130-001
1. UNPLUG THE OVERHEAT DETECTION ELECTRICAL
CONNECTOR(5)
2. CUT AND REMOVE LOCKWIRE, LOOSE KNURLED KNOB
(6) AND UNPLUG THE BATTERY ELECTRICAL CONNECTOR(7)
3. DISCONNECT THE TWO BATTERY VENTILATION DUCTS
(1)
4. LOOSE THE HOLD-DOWN(3) AND DISENGAGE AND REMOVE THE STRAPS(2) KEEPING THE BATTERY(8)
5. REMOVE THE BATTERY

*** CONTINUED ***


AH

24-31-85
RAI 10020-004
2-400 PAGE
2
DEC 01/14

EMER BATTERY REMOVAL AND


INSTALLATION

003

24-31-85

RAI 10020-004
3

DEC14

____________
INSTALLATION
REF.FIG.243115-RAI-00130
1. CLEAN AND INSPECT BATTERY(8) INTERFACE AND/
OR COMPONENT ADJACENT AREA
2. POSITION BATTERY INTO THE RELEVANT BOX(4)
3. INSTALL AND ENGAGE THE STRAPS(2) IN THE HOLD
-DOWN(3). CLAMP THE HOLD-DOWN
4. CONNECT THE TWO BATTERY VENTILATION DUCTS(1)
5. PLUG THE BATTERY ELECTRICAL CONNECTOR(7) BY
MEANS OF KNURLED KNOB(6). SAFETY CONNECTOR
6. PLUG THE OVERHEAT DETECTION ELECTRICAL CONNECTOR(5)

004

________
CLOSE-UP
REF.FIG.243115-RAI-00120-001(FIG.1) AND 243115RAI-00130-001(FIG.2)
1. ON L ELECTRONICS RACK
CLOSE ACCESS DOOR 221AZ
2. REMOVE THE WARNING NOTICE FROM PANEL 29VU
(FIG.1-C)

005

________________
OPERATIONAL
TEST
THIS TEXT IS NOT APPLICABLE

006

___________________________
POWER
SUPPLY FROM BATTERIES
SEE JOB INSTRUCTION CARD
243100-EAD-10000

*** CONTINUED ***


AH

24-31-85
RAI 10020-004
2-400 PAGE
3
DEC 01/14

24-31-85

EMER BATTERY REMOVAL AND


INSTALLATION

007

RAI 10020-004
4

DEC14

____________________________
ADJUSTMENT
OF FDAU TIME BASE
SEE JOB INSTRUCTION CARD
313181-ADJ-10000
*****

AH

E N D

O F

T E X T

*****

24-31-85
RAI 10020-004
2-400 PAGE
4
DEC 01/14

24-31-85
5

AH

CONTROLS AND INDICATING

RAI 10020-004
DEC14

24-31-85
RAI 10020-004

2-400

PAGE
5
DEC 01/14

24-31-85
6

AH

EMER BATTERY REMOVAL AND


INSTALLATION

RAI 10020-004
DEC14

24-31-85
RAI 10020-004

2-400

PAGE
6
DEC 01/14

24-31-85

EMER BATTERY REMOVAL AND


INSTALLATION

RAI 10020-006
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 114
221
: 114CR
221AZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELECTRIC
MECHANIC
ELAPSED TIME

SPARE

: 01 BATTERY 243115

_________
MAN-HOURS
01
01

PUBLICATION
___________
JIC

: POWER SUPPLY FROM


BATTERY

AH

24-31-00-EAD-10000

24-31-85
RAI 10020-006
2-400 PAGE
1
DEC 01/14

24-31-85

EMER BATTERY REMOVAL AND


INSTALLATION

001

RAI 10020-006
2

DEC14

___________
PREPARATION
REF.FIG.243115-RAI-00120-001(FIG.1) AND 243115RAI-00130-001(FIG.2)
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO DC EXTERNAL POWER RECEPTACLE (ON PANEL 5002VU/FIG.1-B) AND THE ACCESS DOOR 114BR(FIG.1-A) IS CLOSED
2. ON PANEL 29VU(FIG.1-C) MAKE CERTAIN THAT:
BAT SELECTOR SWITCH 7PA IS IN OFF POSITION
3. DISPLAY A WARNING NOTICE ON PANEL 29VU PROHIBITING POWER SUPPLY TO THE SYSTEM
4. ON L ELECTRONICS RACK 80VU
OPEN ACCESS DOOR 221AZ (FIG.2-A)

002

_______
REMOVAL
REF.FIG.243115-RAI-00130-001
1. UNPLUG THE OVERHEAT DETECTION ELECTRICAL
CONNECTOR(5)
2. CUT AND REMOVE LOCKWIRE, LOOSE KNURLED KNOB
(6) AND UNPLUG THE BATTERY ELECTRICAL CONNECTOR(7)
3. DISCONNECT THE TWO BATTERY VENTILATION DUCTS
(1)
4. LOOSE THE HOLD-DOWN(3) AND DISENGAGE AND REMOVE THE STRAPS(2) KEEPING THE BATTERY(8)
5. REMOVE THE BATTERY

*** CONTINUED ***


AH

24-31-85
RAI 10020-006
2-400 PAGE
2
DEC 01/14

24-31-85

EMER BATTERY REMOVAL AND


INSTALLATION

003

RAI 10020-006
3

DEC14

____________
INSTALLATION
REF.FIG.243115-RAI-00130
1. CLEAN AND INSPECT BATTERY(8) INTERFACE AND/
OR COMPONENT ADJACENT AREA
2. POSITION BATTERY INTO THE RELEVANT BOX(4)
3. INSTALL AND ENGAGE THE STRAPS(2) IN THE HOLD
-DOWN(3). CLAMP THE HOLD-DOWN
4. CONNECT THE TWO BATTERY VENTILATION DUCTS(1)
5. PLUG THE BATTERY ELECTRICAL CONNECTOR(7) BY
MEANS OF KNURLED KNOB(6). SAFETY CONNECTOR
6. PLUG THE OVERHEAT DETECTION ELECTRICAL CONNECTOR(5)

004

________
CLOSE-UP
REF.FIG.243115-RAI-00120-001(FIG.1) AND 243115RAI-00130-001(FIG.2)
1. ON L ELECTRONICS RACK
CLOSE ACCESS DOOR 221AZ
2. REMOVE THE WARNING NOTICE FROM PANEL 29VU
(FIG.1-C)

005

________________
OPERATIONAL
TEST
THIS TEXT IS NOT APPLICABLE

006

___________________________
POWER
SUPPLY FROM BATTERIES
SEE JOB INSTRUCTION CARD
243100-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-31-85
RAI 10020-006
2-400 PAGE
3
DEC 01/14

24-31-85
4

AH

CONTROLS AND INDICATING

RAI 10020-006
DEC14

24-31-85
RAI 10020-006

2-400

PAGE
4
DEC 01/14

24-31-85
5

AH

EMER BATTERY REMOVAL AND


INSTALLATION

RAI 10020-006
DEC14

24-31-85
RAI 10020-006

2-400

PAGE
5
DEC 01/14

24-32-00

OPT OF DC AND ACW GEN


DE-ENERGIZATION BY FIRE
HANDLE

OPT 10000-001
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: ENGINE START (PROPELLER


BRAKE RELEASED) USING
BATTERY

AH

72-00-00-ERU-10035

24-32-00
OPT 10000-001
2-400 PAGE
1
DEC 01/14

OPT OF DC AND ACW GEN


DE-ENERGIZATION BY FIRE
HANDLE

001

24-32-00

OPT 10000-001
2

DEC14

___________
PREPARATION
REF.FIG.244000-CHK-00100
OPEN SAFETY CLIPS AND TAG THE FOLLOWING CIRCUIT
BREAKERS:
- ON PANEL 21VU
3KF ENG CTL/ENG1/FEATH CTL & AFU
4KF ENG CTL/ENG2/FEATH CTL & AFU
- ON PANEL 121VU
1HA AIR BLEED/COMPT TEMP/ENG 1 BLEED/SO VALVE
/BLEED
2HA AIR BLEED/COMPT TEMP/ENG 2 BLEED/SO VALVE
/BLEED
1QG FUEL/LP VALVES/ENG1 MOTOR 1
2QG FUEL/LP VALVES/ENG2 MOTOR 1
3QG FUEL/LP VALVES/ENG1 MOTOR 2
4QG FUEL/LP VALVES/ENG2 MOTOR 2
- ON PANEL 122VU
28DM DE ICING/SO & REG/VALVES 1 & 2
2KY ENG IND/PROP BRK/PWR SPLY
4KY ENG IND/PROP BRK/CTL & IND

002

ENGINE IDLE RUN-UP


__________________
USING BATTERY
_____________
SEE JOB INSTRUCTION CARD
720000-ERU-10035

003

________________
OPERATIONAL
TEST
NOTE: FOR AIRCRAFT WITH PEC PLACE THE CONDITION
LEVER IN RPM OR AUTO POSITION.
IN THIS CONFIGURATION BOTH ACW GENERATORS
AND DC STARTER/GENERATORS ARE ON LINE
(ACW BUS OFF FOR ACW BUS 1 (2) AND
DC BUS OFF FOR DC BUS 1 (2)ARE OFF)
REF.FIG.261000-OPT-00100
1. ON OVERHEAD PANEL PULL ENG 1 (2) FIRE HANDLE
*** CONTINUED ***
AH

24-32-00
OPT 10000-001
2-400 PAGE
2
DEC 01/14

24-32-00

OPT OF DC AND ACW GEN


DE-ENERGIZATION BY FIRE
HANDLE

OPT 10000-001
3

DEC14

7WD (8WD).
WARNING: DO NOT PRESS THE SQUIBS PUSHBUTTONS
REF.FIG.243181-OPT-00100
2. ON PANEL 26VU MAKE CERTAIN THAT:
- FAULT LEGEND OF ACW GEN 1 (2) PUSHBUTTON
SWITCH 15XU (16XU) COMES ON.
3. ON PANEL 29VU MAKE CERTAIN THAT:
- FAULT LEGEND OF DC GEN 1 (2) PUSHBUTTON
SWITCH 23PU (24PU) COMES ON.
REF.FIG.242100-OPT-00100
4. ON PANEL 175WW MAKE CERTAIN THAT:
- ELEC CAUTION LIGHT COMES ON.
5. MAKE CERTAIN THAT:
- CAPT AND F/O MASTER CAUTION LIGHT COME ON
ON WITH THE ACTIVATION OF ASSOCIATED
SINGLE CHIME.
004

________
CLOSE
UP
1. ON OVERHEAD PANEL PUSH IN ENG 1 (2) FIRE
HANDLE
NOTE: WIRELOCK FIRE HANDLES WITH LOCKWIRE
DIA 1MM (0,04 IN) ANNEALED ALUMINIUM
1050A (A5)
2. CHECK THAT ALL FAULT LEGENDS AND CAUTION
LIGHTS ARE OFF
3. CLOSE THE FOLLOWING CIRCUIT BREAKERS:
- ON PANEL 21
3KF
4KF
- ON PANEL 121VU
*** CONTINUED ***
AH

24-32-00
OPT 10000-001
2-400 PAGE
3
DEC 01/14

24-32-00

OPT OF DC AND ACW GEN


DE-ENERGIZATION BY FIRE
HANDLE

OPT 10000-001
4

DEC14

1HA
2HA
1QG
2QG
3QG
4QG
- ON PANEL 122VU
28DM
8DN
2KY
4KY
005

________________
ENGINE
SHUT-DOWN
SEE JOB INSTRUCTION CARD
720000-ERU-10035
*****

AH

E N D

O F

T E X T

*****

24-32-00
OPT 10000-001
2-400 PAGE
4
DEC 01/14

24-32-00
5

AH

C/B PANELS

OPT 10000-001
DEC14

24-32-00
OPT 10000-001

2-400

PAGE
5
DEC 01/14

24-32-00
6

AH

ENGINE FIRE HANDLE AND


WARNING

OPT 10000-001
DEC14

24-32-00
OPT 10000-001

2-400

PAGE
6
DEC 01/14

24-32-00
7

AH

CONTROLS AND INDICATING

OPT 10000-001
DEC14

24-32-00
OPT 10000-001

2-400

PAGE
7
DEC 01/14

24-32-00
8

AH

CONTROLS AND INDICATING

OPT 10000-001
DEC14

24-32-00
OPT 10000-001

2-400

PAGE
8
DEC 01/14

24-32-00

OPT OF DC AND ACW GEN


DE-ENERGIZATION BY FIRE
HANDLE

OPT 10000-002
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC
JIC

: ENGINE START (PROPELLER


BRAKE RELEASED) USING
BATTERY
: PRINCIPLE OF CDS USE
(DISPLAY UNITS
EXPLORATION)

AH

72-00-00-ERU-10035
31-63-00-PRO-10000

24-32-00
OPT 10000-002
2-400 PAGE
1
DEC 01/14

24-32-00

OPT OF DC AND ACW GEN


DE-ENERGIZATION BY FIRE
HANDLE

001

OPT 10000-002
2

DEC14

___________
PREPARATION
REF.FIG.244000-CHK-00100
OPEN SAFETY CLIPS AND TAG THE FOLLOWING CIRCUIT
BREAKERS:
- ON PANEL 21VU
3KF ENG CTL/ENG1/FEATH CTL & AFU
4KF ENG CTL/ENG2/FEATH CTL & AFU
- ON PANEL 121VU
1HA AIR BLEED/COMPT TEMP/ENG 1 BLEED/SO VALVE
/BLEED
2HA AIR BLEED/COMPT TEMP/ENG 2 BLEED/SO VALVE
/BLEED
1QG FUEL/LP VALVES/ENG1 MOTOR 1
2QG FUEL/LP VALVES/ENG2 MOTOR 1
3QG FUEL/LP VALVES/ENG1 MOTOR 2
4QG FUEL/LP VALVES/ENG2 MOTOR 2
- ON PANEL 122VU
28DM DE ICING/SO & REG/VALVES 1 & 2
2KY ENG IND/CTL/PROP BRK/PWR IND
4KY ENG IND/CTL/PROP BRK/CTL & IND

002

ENGINE IDLE RUN-UP


__________________
USING BATTERY
_____________
SEE JOB INSTRUCTION CARD
720000-ERU-10035

003

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
*** CONTINUED ***
AH

24-32-00
OPT 10000-002
2-400 PAGE
2
DEC 01/14

24-32-00

OPT OF DC AND ACW GEN


DE-ENERGIZATION BY FIRE
HANDLE

OPT 10000-002
3

DEC14

DISPLAY UNITS (DU).


004

________________
OPERATIONAL
TEST
NOTE: FOR AIRCRAFT WITH PEC PLACE THE CONDITION
LEVER IN RPM OR AUTO POSITION.
IN THIS CONFIGURATION BOTH ACW GENERATORS
AND DC STARTER/GENERATORS ARE ON LINE
(ACW BUS OFF FOR ACW BUS 1 (2) AND
DC BUS OFF FOR DC BUS 1 (2) ARE OFF).
REF. FIG. 261000-OPT-00100
1. ON LH EFCP, PRESS CLR PUSH BUTTON
2. ON OVERHEAD PANEL PULL ENG 1 (2) FIRE HANDLE
WARNING: DO NOT PRESS THE SQUIBS PUSHBUTTONS
REF. FIG. 243181-OPT-00100
3. ON PANEL 26VU MAKE CERTAIN THAT:
- FAULT LEGEND OF ACW GEN 1 (2) PUSHBUTTON
SWITCH COMES ON.
4. ON PANEL 29VU MAKE CERTAIN THAT:
- FAULT LEGEND OF DC GEN 1 (2) PUSHBUTTON
SWITCH COMES ON.
REF. FIG. 242100-OPT-00100
5. ON MFD UPPER WINDOW, IN ELEC SD PAGE
- AMBER DC GEN 1 FAULT SYMBOL IS DISPLAYED
- AMBER DC GEN 2 FAULT SYMBOL IS DISPLAYED
- YELLOW ARROWS SYMBOLS ARE DISPLAYED ON
EMER AND MAIN BAT
- AMBER AC BUS 1 OFF AND AC BUS 2 OFF
SYMBOL ARE DISPLAYED
- AMBER DC BUS 1 OFF AND DC BUS 2 OFF
SYMBOL ARE DISPLAYED
- SHED LEGENDS ABOVE UTLY BUS 1 AND
*** CONTINUED ***
AH

24-32-00
OPT 10000-002
2-400 PAGE
3
DEC 01/14

OPT OF DC AND ACW GEN


DE-ENERGIZATION BY FIRE
HANDLE

24-32-00

OPT 10000-002
4

DEC14

UTLY BUS 2 SYMBOLES ARE DISPLAYED.


- GREEN EMER BUS, ESS BUS AND AC STBY
BUS SYMBOLS ARE DISPLAYED.
- AMBER INV2 FAULT SYMBOL IS DISPLAYED.
6. ON MFD UPPER WINDOW, IN HYD/ACW SD PAGE:
- AMBER ACW GEN 1 FAULT SYMBOL IS
DISPLAYED
- AMBER ACW GEN 2 FAULT SYMBOL IS
DISPLAYED
- AMBER ACW BUS 1 OFF AND ACW BUS 2 OFF
SYMBOLS ARE DISPLAYED.
7. ON EWD, IN ALERT WINDOW (DO NOT PAY
ATTENTION TO OTHER MESSAGES)
- ELEC DC GEN 1+2 MESSAGE AND DUAL DC
LOSS ASSOCIATED PROCEDURE ARE DISPLAYED.
8. MAKE CERTAIN THAT:
- MASTER WARNING LIGHTS COME ON WITH THE
ACTIVATION OF ASSOCIATED CRC.
- MASTER CAUTION LIGHTS COME ON WITH THE
ACTIVATION OF ASSOCIATED SINGLE CHIME.
005

________
CLOSE
UP
1. ON OVERHEAD PANEL PUSH IN ENG 1 (2) FIRE
HANDLE
NOTE: WIRELOCK FIRE HANDLES WITH LOCKWIRE
DIA 1MM (0,04 IN) ANNEALED ALUMINIUM
1050A (A5)
2. CHECK THAT ALL FAULT LEGENDS AND CAUTION
LIGHTS ARE OFF
A. ON MFD UPPER WINDOW, IN ELEC SD PAGE
AND HYD/ACW PAGE:
- YELLOW ARROWS SYMBOLS ON MAIN AND
EMER BAT ARE NO LONGER DISPLAYED.
- SHED LEGENDS ARE NO LONGER DISPLAYED.
- ALL AMBER SYMBOLS PREVIOUSLY
*** CONTINUED ***
AH

24-32-00
OPT 10000-002
2-400 PAGE
4
DEC 01/14

24-32-00

OPT OF DC AND ACW GEN


DE-ENERGIZATION BY FIRE
HANDLE

OPT 10000-002
5

DEC14

MENTIONED BECOME GREEN.


B. ON EWD, IN ALERT WINDOW (DO NOT PAY
ATTENTION TO OTHER MESSAGES):
- ELEC DC GEN 1+2 MESSAGE AND
DUAL DC LOSS ASSOCIATED PROCEDURE
ARE NO LONGER DISPLAYED.
3. CLOSE THE FOLLOWING CIRCUIT BREAKERS:
- ON PANEL 21
3KF
4KF
- ON PANEL 121VU
1HA
2HA
1QG
2QG
3QG
4QG
- ON PANEL 122VU
28DM
8DN
2KY
4KY
006

________________
ENGINE
SHUT-DOWN
SEE JOB INSTRUCTION CARD
720000-ERU-10035
*****

AH

E N D

O F

T E X T

*****

24-32-00
OPT 10000-002
2-400 PAGE
5
DEC 01/14

24-32-00
6

AH

C/B PANELS

OPT 10000-002
DEC14

24-32-00
OPT 10000-002

2-400

PAGE
6
DEC 01/14

24-32-00
7

AH

ENGINE FIRE HANDLE AND


WARNING

OPT 10000-002
DEC14

24-32-00
OPT 10000-002

2-400

PAGE
7
DEC 01/14

24-32-00
8

AH

CONTROLS AND INDICATING

OPT 10000-002
DEC14

24-32-00
OPT 10000-002

2-400

PAGE
8
DEC 01/14

24-32-00
9

AH

CONTROLS AND INDICATING

OPT 10000-002
DEC14

24-32-00
OPT 10000-002

2-400

PAGE
9
DEC 01/14

24-32-61

CHECK OF STARTER
GENERATOR BRUSHES WEAR

CHK 10000-003
1

MAR15

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC

: CHECK OF BRUSHES WEAR


(BY MEANS OF GRADUATED
RULE)
: CHECK OF BRUSHES WEAR
(BY MEANS OF BRUSH GAUGE
P/N P611845)

AH

24-32-61-CHK-10005
24-32-61-CHK-10006

24-32-61
CHK 10000-003
2-400 PAGE
1
MAR 01/15

24-32-61

CHECK OF STARTER
GENERATOR BRUSHES WEAR

001

CHK 10000-003
2

MAR15

_______
CAUTION
THIS PROCEDURE IS NOT APPLICABLE FOR
STARTER-GENERATOR P/N 8260-124.

002

____
NOTE
FOR THIS PROCEDURE, TWO METHODS ARE PURPOSED
USING DIFFERENT TOOLS. CHOOSE JIC YOU WANT TO
PERFORM.

003

CHECK OF STARTER GENERATOR BRUSHES WEAR


_______________________________________
(BY MEANS OF GRADUATED RULE)
____________________________
SEE JOB INSTRUCTION CARD
243261-CHK-10005

004

CHECK OF STARTER GENERATOR BRUSHES WEAR


_______________________________________
(BY MEANS OF BRUSH GAUGE P/N P611845)
_____________________________________
SEE JOB INSTRUCTION CARD
243261-CHK-10006
*****

AH

E N D

O F

T E X T

*****

24-32-61
CHK 10000-003
2-400 PAGE
2
MAR 01/15

24-32-61

CHECK OF BRUSHES WEAR


(BY MEANS OF GRADUATED
RULE)

CHK 10005-002
1

MAR15

ZONING DATA
___________
ZONE
ACCESS

: 436
446
: 436AR 446AR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
MECHANIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

AH

24-32-61
CHK 10005-002
2-400 PAGE
1
MAR 01/15

24-32-61

CHECK OF BRUSHES WEAR


(BY MEANS OF GRADUATED
RULE)

001

CHK 10005-002
2

MAR15

_______
CAUTION
THIS PROCEDURE IS NOT APPLICABLE FOR
STARTER-GENERATOR P/N 8260-124.

002

___________
PREPARATION
REF. FIG. 242261-RAI-00100
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO THE DC EXTERNAL POWER
RECEPTACLE (ON PANEL 5002VU / DETAIL D)
AND TO THE AC EXTERNAL POWER RECEPTACLE (ON
PANEL 5000VU / DETAIL B) AND THE ACCESS
DOORS 114BR (DETAIL C) AND 114CR (DETAIL A)
ARE CLOSED.
2. DISPLAY A WARNING NOTICE ON PANELS 27VU
(DETAIL F) AND 29VU (DETAIL E) PROHIBITING
POWER SUPPLY TO THE SYSTEM AND ENGINE
STARTING.
3. OPEN ENGINE COWLS 436AR(446AR).

003

CHECK OF BRUSHES FOR WEAR (BY MEANS OF


______________________________________
GRADUATED RULE)
_______________
REF. FIG. 243261-CHK-00100
1. UNLOCK AND REMOVE SCREW (1).
2. REMOVE COVER BAND (2).
CAUTION: NEVER REMOVE BRUSHES FROM THEIR
GUIDES WHEN CHECKING THEIR LENGTH.
ONLY REMOVE BRUSHES WHEN THEY HAVE TO
BE REPLACED WITH NEW ONES.
NOTE: BRUSHES MUST BE CHECKED TO DETERMINE THE
LIMIT OF USE AND CONDITION OF THE
STARTER GENERATOR. THE PROCEDURE IS THE
*** CONTINUED ***
AH

24-32-61
CHK 10005-002
2-400 PAGE
2
MAR 01/15

24-32-61

CHECK OF BRUSHES WEAR


(BY MEANS OF GRADUATED
RULE)

CHK 10005-002
3

MAR15

SAME FOR EACH ONE OF BOTH ENGINES AND


APPLIES ON THE TWO BRUSHES OF THE THREE
ACCESSIBLE BRUSH LINES (SIX BRUSHES HAVE
TO BE CHECKED).
CAUTION: DO NOT TOUCH THE COMMUTATOR WITH
GRADUATED RULE.
3. MOVE APART THE BRUSH WIRES (3) TO CLEAR THE
UPPER PART OF BRUSHES (4).
4. INSTALL GRADUATED RULE BETWEEN THE TWO
BRUSH SPRINGS (5).
5. SET THE GRADUATED RULE IN CONTACT AGAINST
THE BRUSH GUIDE (REFERENCE FACE) AND
AGAINST THE BRUSH TO BE CHECKED.
6. SET GRADUATED RULE IN CONTACT WITH BRUSH
SPRINGS (5).
7. MEASURE AND RECORD LENGTH(B) FOR EACH BRUSH
OF THE THREE ACCESSIBLE BRUSH LINES.
NOTE: THIS LENGTH (B) HAS TO BE SIMILAR FOR
EACH BRUSH OF THE SAME BRUSH LINE.
CAUTION: BRUSH LIMIT OF LIFE IS REACHED WHEN
(LENGTH (B) <=1MM (0.039 IN), SEE
DETAIL E).
NOTE: IF A BRUSH MUST BE CHANGED, REFER TO:
JIC 243261-RAI-10010
8. ANALYSE BRUSH WEAR AND ESTIMATE THE
REMAINING BRUSH SERVICE LIFE USING THE
FOLLOWING FORMULA:
IF B EXPRESSED IN INCHES:
Y=(B-0.4) X FH / (0.9-B)
*** CONTINUED ***
AH

24-32-61
CHK 10005-002
2-400 PAGE
3
MAR 01/15

24-32-61

CHECK OF BRUSHES WEAR


(BY MEANS OF GRADUATED
RULE)

CHK 10005-002
4

MAR15

IF B EXPRESSED IN MILLIMETERS:
Y=(B-1) X FH / (23-B)
Y
B

= ESTIMATE BRUSH REMAINING SERVICE LIFE


= ACTUAL LENGTH OF THE BRUSH WEAR
LIMIT
FH = FLIGHT HOURS CARRY OUT SINCE
THE PREVIOUS BRUSH REPLACEMENT
NOTE: PERFORM A NEW CHECK FOLLOWING THE
PREVIOUS ESTIMATE SERVICE LIFE.
DETERMINE IF THIS NEW CHECK CAN BE
ASSOCIATE TO THE NEXT MAINTENANCE STEP
(BRUSH AND BEARING REPLACEMENT OR
OVERHAUL).
WARNING: IF ONE BRUSH HAS REACHED HIS LIMIT OF
LIFE, ALL BRUSHES HAVE TO BE
REPLACED.
9. CLEANING OF THE STARTER GENERATOR:
CAUTION: TAKE ALL PRECAUTIONS REQUIRED TO
PREVENT NOZZLE FROM COMING INTO
CONTACT WITH COMMUTATOR.
- USING ADAPTED BLOWER AND DRY COMPRESSED
AIR (MAX 7.5 BAR / 110 PSI), BLOW OFF
ANY BRUSH DUST THAT MAY HAVE ACCUMULATED
INSIDE THE STARTER GENERATOR, ESPECIALLY
AROUND COMMUTATOR AND IN AREA BETWEEN
STATOR AND ARMATURE.
10. INSTALL COVER BAND (2) AND SECURE IT WITH
SCREW (1).
11. TIGHTEN SCREW (1) (TIGHTENING TORQUE
VALUE: 0.2 DAN.M / 1.475 FT.LBS).
CAUTION: MAKE SURE THAT THE COVER BAND IS ONLY
ROTATED IN THE OPPOSITE DIRECTION OF
ARMATURE DIRECTION IN ORDER TO AVOID
ANY MODIFICATION OF BRUSH WIRES
*** CONTINUED ***
AH

24-32-61
CHK 10005-002
2-400 PAGE
4
MAR 01/15

24-32-61

CHECK OF BRUSHES WEAR


(BY MEANS OF GRADUATED
RULE)

CHK 10005-002
5

MAR15

POSITION.
004

________
CLOSE
UP
REF. FIG. 242261-RAI-00100
1. CLOSE ENGINE COWLS.
2. REMOVE WARNING NOTICE FROM PANELS 27VU AND
29VU.
*****

AH

E N D

O F

T E X T

*****

24-32-61
CHK 10005-002
2-400 PAGE
5
MAR 01/15

24-32-61
6

AH

CHECK OF BRUSHES WEAR


(BY MEANS OF GRADUATED
RULE)

CHK 10005-002
MAR15

24-32-61
CHK 10005-002

2-400

PAGE
6
MAR 01/15

24-32-61
7

AH

CONTROL PANEL AND


ACCESS DOORS

CHK 10005-002
MAR15

24-32-61
CHK 10005-002

2-400

PAGE
7
MAR 01/15

24-32-61

CHECK OF BRUSHES WEAR


(BY MEANS OF BRUSH GAUGE
P/N P611845)

CHK 10006-002
1

MAR15

ZONING DATA
___________
ZONE
ACCESS

: 436
446
: 436AR 446AR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
MECHANIC

ELAPSED TIME

GSE

: 01 BRUSH GAUGE

AH

___
MEN

_________
MAN-HOURS
01

P611845

24-32-61
CHK 10006-002
2-400 PAGE
1
MAR 01/15

24-32-61

CHECK OF BRUSHES WEAR


(BY MEANS OF BRUSH GAUGE
P/N P611845)

001

CHK 10006-002
2

MAR15

_______
CAUTION
THIS PROCEDURE IS NOT APPLICABLE FOR
STARTER-GENERATOR P/N 8260-124.

002

___________
PREPARATION
REF. FIG. 242261-RAI-00100
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO THE DC EXTERNAL POWER
RECEPTACLE (ON PANEL 5002VU / DETAIL D)
AND TO THE AC EXTERNAL POWER RECEPTACLE (ON
PANEL 5000VU / DETAIL B) AND THE ACCESS
DOORS 114BR (DETAIL C) AND 114CR (DETAIL A)
ARE CLOSED.
2. DISPLAY A WARNING NOTICE ON PANELS 27VU
(DETAIL F) AND 29VU (DETAIL E) PROHIBITING
POWER SUPPLY TO THE SYSTEM AND ENGINE
STARTING.
3. OPEN ENGINE COWLS 436AR(446AR).

003

CHECK OF BRUSHES WEAR (BY MEANS OF BRUSH


________________________________________
GAUGE P/N P611845)
__________________
REF. FIG. 243261-CHK-00110
1. UNLOCK AND REMOVE SCREW (1).
2. REMOVE COVER BAND (2).
CAUTION: NEVER REMOVE BRUSHES FROM THEIR
GUIDES WHEN CHECKING THEIR LENGTH.
ONLY REMOVE BRUSHES WHEN THEY HAVE TO
BE REPLACED WITH NEW ONES.
NOTE: BRUSHES MUST BE CHECKED TO DETERMINE THE
LIMIT OF USE AND CONDITION OF THE
STARTER GENERATOR. THE PROCEDURE IS THE
*** CONTINUED ***
AH

24-32-61
CHK 10006-002
2-400 PAGE
2
MAR 01/15

24-32-61

CHECK OF BRUSHES WEAR


(BY MEANS OF BRUSH GAUGE
P/N P611845)

CHK 10006-002
3

MAR15

SAME FOR EACH ONE OF BOTH ENGINES AND


APPLIES ON THE TWO BRUSHES OF THE THREE
ACCESSIBLE BRUSH LINES (SIX BRUSHES HAVE
TO BE CHECKED).
CAUTION: DO NOT TOUCH THE COMMUTATOR WITH
BRUSH GAUGE.
3. MOVE APART THE BRUSH WIRES (3) TO CLEAR THE
UPPER PART OF BRUSHES (4).
4. INSTALL BRUSH GAUGE BETWEEN THE TWO BRUSH
SPRINGS (5).
5. SET THE BRUSH GAUGE IN CONTACT AGAINST THE
BRUSH GUIDE (REFERENCE FACE) AND AGAINST
THE BRUSH TO BE CHECKED.
6. SET BRUSH GAUGE IN CONTACT WITH BRUSH
SPRINGS (5).
REF. FIG. 243261-CHK-00120
7. FOR EACH BRUSH OF THE THREE ACCESSIBLE
BRUSH LINES, CHECK AND ANALYSE USING TABLE
ON FIGURE.
NOTE: IF A BRUSH MUST BE CHANGED, REFER TO:
JIC 243261-RAI-10010
WARNING: IF ONE BRUSH HAS REACHED HIS LIMIT OF
LIFE, ALL BRUSHES HAVE TO BE
REPLACED.
9. CLEANING OF THE STARTER GENERATOR:
CAUTION: TAKE ALL PRECAUTIONS REQUIRED TO
PREVENT NOZZLE FROM COMING INTO
CONTACT WITH COMMUTATOR.
- USING ADAPTED BLOWER AND DRY COMPRESSED
AIR (MAX 7.5 BAR / 110 PSI), BLOW OFF ANY
BRUSH DUST THAT MAY HAVE ACCUMULATED
INSIDE THE STARTER GENERATOR, ESPECIALLY
*** CONTINUED ***
AH

24-32-61
CHK 10006-002
2-400 PAGE
3
MAR 01/15

24-32-61

CHECK OF BRUSHES WEAR


(BY MEANS OF BRUSH GAUGE
P/N P611845)

CHK 10006-002
4

MAR15

AROUND COMMUTATOR AND IN AREA BETWEEN


STATOR AND ARMATURE.
10. INSTALL COVER BAND (2) AND SECURE IT WITH
SCREW (1).
11. TIGHTEN SCREW (1) (TIGHTENING TORQUE
VALUE: 0.2 DAN.M / 1.475 FT.LBS).
CAUTION: MAKE SURE THAT THE COVER BAND IS ONLY
ROTATED IN THE OPPOSITE DIRECTION OF
ARMATURE DIRECTION IN ORDER TO AVOID
ANY MODIFICATION OF BRUSH WIRES
POSITION.
004

________
CLOSE
UP
REF. FIG. 242261-RAI-00100
1. CLOSE ENGINE COWLS.
2. REMOVE WARNING NOTICE FROM PANELS 27VU AND
29VU.
*****

AH

E N D

O F

T E X T

*****

24-32-61
CHK 10006-002
2-400 PAGE
4
MAR 01/15

24-32-61
5

AH

CHECK OF BRUSHES WEAR


(BY MEANS OF BRUSH GAUGE
P/N P611845)

CHK 10006-002
MAR15

24-32-61
CHK 10006-002

2-400

PAGE
5
MAR 01/15

24-32-61
6

AH

CONTROL PANEL AND


ACCESS DOORS

CHK 10006-002
MAR15

24-32-61
CHK 10006-002

2-400

PAGE
6
MAR 01/15

24-32-61
7

AH

ANALYSIS OF RESULTS

CHK 10006-002
MAR15

24-32-61
CHK 10006-002

2-400

PAGE
7
MAR 01/15

24-32-61

DC STARTER/GENERATOR 1/2
REMOVAL AND INSTALLATION

RAI 10000-002
1

MAR15

ZONING DATA
___________
ZONE
ACCESS

: 436
446
: 436AR 446AR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
MECHANIC

___
MEN

_________
MAN-HOURS
01

ELAPSED TIME

SPARE

: 01 STARTER/GENERATOR-1PU(L)
01 STARTER/GENERATOR-1PU(R)

243260
243260

EXPENDABLE

: 02 O-RING
02 LOCKING-RING
02 O-RING, DRAIN

243260
243260
243260

BULK MATERIAL : SYNTHETIC GREASE


SYNTHETIC OIL
CAF 4
TEFLON TAPE

04-004
03-002
08-038

PUBLICATION
___________
JIC
JIC
JIC

: ENGINE START (PROPELLER


BRAKE RELEASED) USING
DC GROUND POWER UNIT
: PRATT & WHITNEY CANADA
MAINTENANCE MANUAL
: OPENING AND CLOSING OF
HINGED ENGINE COWLS

AH

72-00-00-ERU-10030
72-01-50-PWC-00000
54-00-00-OAC-10000

24-32-61
RAI 10000-002
2-400 PAGE
1
MAR 01/15

24-32-61

DC STARTER/GENERATOR 1/2
REMOVAL AND INSTALLATION

001

RAI 10000-002
2

MAR15

_______
CAUTION
IN CASE OF NEW STARTER-GENERATOR P/N 8260-124
INSTALLATION IN PLACE OF S/G OLDER P/N}S,
VERIFY THAT A/C IS WELL EQUIPPED WITH
MOD-07200 (OR ASSOCIATED SB) FOR FUEL DRAIN
REPLACEMENT.

002

___________
PREPARATION
REF.FIG.242261-RAI-00100 (FIG.1)
REF.FIG.243261-RAI-00100 (FIG.2)
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO DC EXTERNAL POWER RECEPTACLE (ON PANEL 5002VU-FIG.1-D) AND TO AC EXTERNAL POWER RECEPTACLE (ON PANEL 5000VUFIG.1-B)AND THAN THE ACCESS DOORS 114BR
(FIG.1-C) AND 114CR (FIG.1-A) ARE CLOSED
2. ON PANEL 29VU(FIG.1-E) MAKE CERTAIN THAT:
BAT SELECTOR SWITCH 7PA IS IN OFF POSITION
3. DISPLAY A WARNING NOTICE ON PANELS 27VU(FIG.
1-F) AND 29VU, PROHIBITING POWER SUPPLY TO
THE SYSTEM AND ENGINE STARTING
4. OPEN ACCESS DOOR 436AR (446AR) (FIG.2-A)

003

_______________________________
REMOVAL
OF DC STARTER/GENERATOR
REF.FIG.243261-RAI-00100 (FIG.A)
REF.FIG.243261-RAI-00110 (FIG.B)
01. UNPLUG ELECTRICAL CONNECTORS (FIG.B-6)
02. PUT BLANKING CAP ON ELECTRICAL CONNECTORS
03. SLIDE GENERATOR TERMINAL PROTECTIVE CAP
(FIG.A-14)
*** CONTINUED ***
AH

24-32-61
RAI 10000-002
2-400 PAGE
2
MAR 01/15

24-32-61

DC STARTER/GENERATOR 1/2
REMOVAL AND INSTALLATION

RAI 10000-002
3

MAR15

04. CUT TEFLON (FIG.A-15) SECURING MONITORING


WIRES (FIG.A-11A,12E AND 13D) TO POWER
SUPPLY WIRES (FIG.A-1E AND 2B).
05. REMOVE NUTS (FIG.A-3 AND 9) AND WASHERS
(FIG. A-4 AND 10)
06. MARK AND DISCONNECT TERMINAL LUG OF MONITORING WIRE (FIG.A-12E) AND THOSE OF POWER
SUPPLY WIRES (FIG.A-2B AND 1E)
07. REMOVE NUTS (FIG.A-5 AND 7) AND WASHERS
(FIG.A-6 AND 8)
08. MARK AND DISCONNECT TERMINAL LUGS OF MONITORING WIRES (FIG.A-13D AND 11A)
09. DISCONNECT DRAIN LINE (FIG.B-5)
NOTE: REMOVE AND DISCARD O-RING (FIG.B-12)
10. PUT BLANKING CAP ON DRAIN LINE
11. REMOVE NUTS (FIG.B-2) SECURING VENTILATION
DUCT (AIR INTAKE) (FIG.B-3)
12. REMOVE VENTILATION DUCT
13. NOTE INSTALLATION POSITION OF CLAMP (FIG.B10) AND POSITION OF BOTH HALF-RINGS (FIG.B11) WITH REGARD TO CLAMP FOR REINSTALLATION.
NOTE: HALF-RINGS ARE DIFFERENTS.
14. REMOVE LOCKWIRE, CLAMP (FIG.B-10) AND HALFRINGS (FIG.B-11) SECURING STARTER/GENERATOR
(FIG.B-1)
NOTE : STARTER/GENERATOR MUST BE REMOVED
VERY CAREFULLY TO AVOID DAMAGING
SPLINED DRIVE SHAFT
*** CONTINUED ***
AH

24-32-61
RAI 10000-002
2-400 PAGE
3
MAR 01/15

24-32-61

DC STARTER/GENERATOR 1/2
REMOVAL AND INSTALLATION

RAI 10000-002
4

MAR15

15. REMOVE STARTER/GENERATOR


16. REMOVE AND DISCARD O-RING (FIG.B-4)
004

_________________________________
INSTALLATION
OF STARTER/GENERATOR
REF.FIG.243261-RAI-00100 (FIG.A)
REF.FIG.243261-RAI-00110 (FIG.B)
NOTE: FOR ADAPTER (FIG.B-8) THE TORQUE VALUE OF NUTS (FIG.B-9) IS BETWEEN 3.1
AND 3.4 M.DAN (275 AND 300 LBF X IN)
01. POSITION NEW O-RING (FIG.B-4) LUBRICATED
WITH SYNTHETIC OIL
NOTE: IF THE SHAFT SEAL IS NOT PROPERLY
INSTALLED, THERE WOULD BE HIGH RISK OF
ENGINE IFSD DUE TO OIL LOW PRESSURE
02. CLEAN AND INSPECT ENGINE HOUSING AND STARTER/GENERATOR INTERFACE AREA
03. LUBRICATE STARTER/GENERATOR (FIG.B-1) DRIVE
SHAFT BEFORE INSTALLATION WITH SYNTHETIC
GREASE
NOTE: STARTER/GENERATOR MUST BE INSTALLED
VERY CAREFULLY TO AVOID DAMAGING SPLI
NED DRIVE SHAFT AND O-RING
CAUTION:INSTALL BOTH HALF-RINGS (FIG.B-11) AND
CLAMP (FIG. B-10) FOLLOWING THE
INDICATIONS RECORDED DURING THE
REMOVAL.
04. INSTALL STARTER/GENERATOR ON ENGINE, ALIGN
WITH LOCATORS AND ATTACH BY MEANS OF
CLAMP (FIG.B-10) EQUIPPED WITH BOTH HALFRINGS (FIG.B-11) AND SAFETY WITH LOCKWIRE.
NOTE: THE APPLICABLE TORQUE VALUE IS BETWEEN 0.25 AND 0.30 M.DAN (21.6 AND 26
*** CONTINUED ***
AH

24-32-61
RAI 10000-002
2-400 PAGE
4
MAR 01/15

24-32-61

DC STARTER/GENERATOR 1/2
REMOVAL AND INSTALLATION

RAI 10000-002
5

MAR15

LBF.IN)
05. INSTALL VENTILATION DUCT (FIG.B-3)
06. INSTALL NUTS (FIG.B-2) SECURING VENTILATION
DUCT. TIGHTEN NUTS
NOTE: THE APPLICABLE TORQUE VALUE IS BETWEEN 0.45 AND 0.5 M.DAN (39 AND 44 LBF
X IN)
07. REMOVE BLANKING CAP FROM DRAIN LINE (FIG.B5)
08. CONNECT DRAIN LINE
NOTE: INSTALL A NEW O-RING (FIG.B-12)
CAUTION: ASSURE POWER WIRES ARE PROPERLY
CONNECTED TO RELEVANT GENERATOR
STUDS. IF NOT, THERE IS A HIGH
RISK OF MULTIPLE EQUIPMENT FAILURES
DUE TO GENERATOR OVERVOLTAGE.
09. CONNECT TERMINAL LUGS OF POWER SUPPLY WIRES
(FIG.A-1E AND 2B) AND THOSE OF MONITORING
WIRES (FIG.A-11A, 13D AND 12E) SO AS THEY
HAVE BEEN MARKED IN THE REMOVAL AND SECURE
BY MEANS OF WASHERS (FIG.A-8,6,10 AND 4)
AND NUTS (FIG.A-9,3,7 AND 5). TIGHTEN NUTS
NOTE: THE TIGHTENING TORQUES INDICATED
IN THE FOLLOWING TABLE FOR
ELECTRICAL CONNECTIONS ARE MANDATORY
------------------------------------------NUT ( WIRE )
TIGHTENING TORQUE
7 ( 11A )
0.4 M.DAN ( 35 LBF.IN )
5 ( 13D )
0.25 M.DAN ( 22 LBF.IN )
3 ( 2B )
1.2 M.DAN ( 106 LBF.IN )
9 (1E-12E)
1.9 M.DAN ( 168 LBF.IN )
------------------------------------------NOTE: USE PIPE WRENCHES TO PREVENT DAMAGING
THE SIDES OF THE TERMINAL BLOCK.
*** CONTINUED ***
AH

24-32-61
RAI 10000-002
2-400 PAGE
5
MAR 01/15

24-32-61

DC STARTER/GENERATOR 1/2
REMOVAL AND INSTALLATION

RAI 10000-002
6

MAR15

10. SECURE MONITORING WIRES (FIG.A-12E,11A AND


13D) TO POWER SUPPLY WIRES (FIG.A-1E AND
2B) AS SHOWN IN FIG.A USING TEFLON (FIG.A15) AND SEAL WITH CAF 4.
11. SLIDE INTO POSITION GENERATOR TERMINAL PROTECTIVE CAP (FIG.A-14)
12. REMOVE BLANKING CAP FROM ELECTRICAL CONNECTORS (FIG.B-6)
13. PLUG IN ELECTRICAL CONNECTOR
14. MARK NUTS (FIG.A-7, 5, 9 AND 3) AND DRAIN
LINE (FIG.B-5) WITH RED VARNISH
005

________
CLOSE
UP
REF.FIG.242261-RAI-00100 (FIG.1)
REF.FIG.243261-RAI-00100 (FIG.2)
1. CLOSE ENGINE COWL 436AR (446AR) (FIG.2-A)
2. REMOVE WARNING NOTICES FROM PANELS 27VU (FIG
1-F) AND 29VU (FIG.1-E)

006

_________________________
ENGINE
GROUND IDLE RUN-UP
SEE JOB INSTRUCTION CARD
720000-ERU-10030

007

______________________________
LEAK
CHECK AFTER ENGINE RUN-UP
SEE JOB INSTRUCTION CARD
(PRATT & WHITNEY CANADA MAINTENANCE MANUAL,
CHAPTER 72-01-50, PAGE BLOCK 500).
1. PERFORM ENGINE RUN-UP AS REQUIRED BY
PRATT & WHITNEY CANADA.
2. CHECK FOR OIL LEAKS AFTER ENGINE SHUT DOWN.
*** CONTINUED ***
AH

24-32-61
RAI 10000-002
2-400 PAGE
6
MAR 01/15

24-32-61

DC STARTER/GENERATOR 1/2
REMOVAL AND INSTALLATION

008

RAI 10000-002
7

MAR15

______________________________________
SHUT
DOWN OF ENGINE GROUND IDLE RUN-UP
SEE JOB INSTRUCTION CARD
720000-ERU-10030

009

_______________________
OPENING
OF HINGED COWLS
SEE JOB INSTRUCTION CARD
540000-OAC-10000

010

LEAKAGE CHECK AT LEVEL OF DC STARTER/GENERATOR


______________________________________________
ATTACHMENT
__________
1. VISUALLY CHECK ENGINE - DC STARTER/GENERATOR
CONNECTION FOR LEAKS.
2. IF NECESSARY, RECTIFY LEAKING COMPONENTS AND
REPEAT TEST.

011

______________________________
CLOSING
OF HINGED ENGINE COWLS
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

24-32-61
RAI 10000-002
2-400 PAGE
7
MAR 01/15

24-32-61
8

AH

CONTROL PANEL AND


ACCESS DOORS

RAI 10000-002
MAR15

24-32-61
RAI 10000-002

2-400

PAGE
8
MAR 01/15

24-32-61
9

AH

GENERATOR TERMINAL

RAI 10000-002
MAR15

24-32-61
RAI 10000-002

2-400

PAGE
9
MAR 01/15

24-32-61
10

AH

RAI OF DC STARTER/
GENERATOR

RAI 10000-002
MAR15

24-32-61
RAI 10000-002

2-400

PAGE
10
MAR 01/15

24-32-61

REMOVAL/INSTALLATION OF
STARTER GENERATOR
BRUSHES

RAI 10010-002
1

MAR15

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC

: DC STARTER/GENERATOR 1/2
REMOVAL AND INSTALLATION

AH

24-32-61-RAI-10000

24-32-61
RAI 10010-002
2-400 PAGE
1
MAR 01/15

24-32-61

REMOVAL/INSTALLATION OF
STARTER GENERATOR
BRUSHES

001

RAI 10010-002
2

MAR15

_______
CAUTION
THIS PROCEDURE IS NOT APPLICABLE FOR
STARTER-GENERATOR P/N 8260-124.

002

________________________________
DC
STARTER/GENERATOR 1/2 REMOVAL
SEE JOB INSTRUCTION CARD
243261-RAI-10000

003

___________________
BRUSHES
REPLACEMENT
REFER TO SIL OF MANUFACTURER 8260-12X-24-017

004

_____________________________________
DC
STARTER/GENERATOR 1/2 INSTALLATION
SEE JOB INSTRUCTION CARD
243261-RAI-10000
*****

AH

E N D

O F

T E X T

*****

24-32-61
RAI 10010-002
2-400 PAGE
2
MAR 01/15

24-32-61
3

AH

RAI 10010-002
MAR15

24-32-61
RAI 10010-002

2-400

PAGE
3
MAR 01/15

24-32-81

DC GEN CONTROL UNIT


OPERATIONAL TEST

OPT 10000-001
1

MAR13

ZONING DATA
___________
ZONE
ACCESS

: 214
: 214BZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELECTRIC
ELAPSED TIME

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: POWER SUPPLY FROM


BATTERIES

AH

24-31-00-EAD-10000

24-32-81
OPT 10000-001
2-400 PAGE
1
MAR 01/13

24-32-81

DC GEN CONTROL UNIT


OPERATIONAL TEST

001

OPT 10000-001
2

MAR13

___________
PREPARATION
REF. FIG. 240000-RAI-00103
1. ON R ELECTRONICS RACK 90VU (B)
OPEN ACCESS DOOR 214BZ

002

_________________________________
ENERGIZING
OF SYSTEM FROM BATTERY
SEE JOB INSTRUCTION CARD
243100-EAD-10000

003

__________________________________________
DC
GENERATOR CONTROL UNIT OPERATIONAL TEST
REF.FIG.243211-OPT-00100
1. ON R ELECTRONICS RACK 90VU SHELF 5(4) (A)
ON DC GCU1(2) FRONT PANEL(B OR C) PRESS THE
CC SWITCH AND VERIFY THAT THE CC INDICATOR
LIGHT COMES ON. AFTER 15 SEC, IF GCU
OPERATES CORRECTLY, CC INDICATOR LIGHT GOES
OFF.IF A FAILURE IS DETECTED, THE CC
INDICATOR LIGHT REMAINS ON AS LONG AS THE
CC SWITCH IS PRESSED.

004

____________________________________
DE-ENERGIZING
OF SYSTEM FROM BATTERY
SEE JOB INSTRUCTION CARD
243100-EAD-10000

005

________
CLOSE
UP
REF.FIG.240000-RAI-00103
1. ON R ELECTRONICS RACK 90VU (B)
CLOSE ACCESS DOOR 214BZ
*****

AH

E N D

O F

T E X T

*****

24-32-81
OPT 10000-001
2-400 PAGE
2
MAR 01/13

24-32-81
3

AH

ACCESS DOORS, CONTROLS


AND INDICATING

OPT 10000-001
MAR13

24-32-81
OPT 10000-001

2-400

PAGE
3
MAR 01/13

24-32-81

DC GEN CONTROL UNIT


REMOVAL AND INSTALLATION

RAI 10000-002
1

APR07

ZONING DATA
___________
ZONE
ACCESS

: 210
214
: 122VU 124VU 125VU 127VU 128VU
214BZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELECTRIC
ELAPSED TIME

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: DC GEN CONTROL UNIT


OPERATIONAL TEST

AH

24-32-81-OPT-10000

24-32-81
RAI 10000-002
2-400 PAGE
1
APR 01/07

24-32-81

DC GEN CONTROL UNIT


REMOVAL AND INSTALLATION

001

RAI 10000-002
2

APR07

___________
PREPARATION
REF. FIG. 240000-RAI-00103
1. OPEN, SAFETY CLIP AND TAG THE FOLLOWING CIRCUIT BREAKERS:
- ON PANEL 122VU (A)
8PG MAIN ELEC PWR-DC/DC EXT PWR INTLK
15PG MAIN ELEC PWR-DC/BPCU DC
35PU(38PU) MAIN ELEC PWR-DC/GCU DC GEN 1
(GCU DC GEN 2)
- ON PANEL 124VU (A)
54PU DC BUS 2 V SNSG/GCU 2
- ON PANEL 125VU (A)
4PG EXT PWR/BPCU CTL
13PU(14PU ON PANEL 128VU) DC GEN1(DC GEN
2)/CTL/EXCN
51PU(52PU ON PANEL 128VU) DC GEN1(DC GEN
2)/CTL/POR
- ON PANEL 127VU (A)
53PU DC GEN1/CTL/BUS V SNSG
2. ON R ELECTRONICS RACK 90VU (B)
OPEN ACCESS DOOR:
- 214BZ

002

REMOVAL OF EQUIPMENT FROM L OR R ELECTRONICS


____________________________________________
RACKS 80VU OR 90VU
__________________
REF. FIG. 310000-RAI-00105
NOTE : THE SHAPE AND QUANTITY OF AFT BACKSHELLS
AS WELL AS THE QUANTITY OF FASTENERS MAY
BE DIFFERENT ACCORDING THE EQUIPMENT.
NEVERTHLESS, THE REMOVAL AND INSTALLATION PROCEDURE IS IDENTICAL.
1. REMOVE CORRESPONDING ACCESS PANEL.
2. UNSCREW KNURLED KNOBS (3) ATTACHING
EQUIPMENT (1) TO RACK (4).
*** CONTINUED ***
AH

24-32-81
RAI 10000-002
2-400 PAGE
2
APR 01/07

24-32-81

DC GEN CONTROL UNIT


REMOVAL AND INSTALLATION

RAI 10000-002
3

APR07

3. PULL EQUIPMENT (1) AND REMOVE FROM ITS


RACK (4).
4. INSTALL PROTECTIVE PLUGS ON EQUIPMENT SIDE
ELECTRICAL CONNECTORS (5).
003

____
NOTE
THE GCU IS DELIVERED 29VDC SETTING.
TO IMPROVE THE PERFORMANCE OF THE BATTERY :
- SET 28 VDC VALUE FOR OPERATION IN HIGH
AMBIENT TEMPERATURE. (FOLLOWING GCU COMPONANT
MAINTENANCE MANUAL)
- SET 30VDC VALUE FOR OPERATION IN LOW
AMBIENT TEMPERATURE. (FOLLOWING GCU COMPONANT
MAINTENANCE MANUAL)

004

INSTALLATION OF EQUIPMENT IN L OR R ELECTRONICS


_______________________________________________
RACKS 80VU OR 90VU
__________________
REF. FIG. 310000-RAI-00105
1. CLEAN AND INSPECT EQUIPMENT (1) AND RACK
(4) INTERFACE AREA.
2. REMOVE PROTECTIVE CAPS INSTALLED ON
EQUIPMENT SIDE ELECTRICAL CONNECTORS (5).
3. INSTALL EQUIPMENT (1) IN ITS RACK (4).
4. BLOCK EQUIPMENT BY MEANS OF ITS KNURLED
ATTACHMENT KNOBS (2) AND (3).

005

________
CLOSE
UP
REF.FIG.240000-RAI-00103
1. ON R ELECTRONICS RACK 90VU (B)
*** CONTINUED ***
AH

24-32-81
RAI 10000-002
2-400 PAGE
3
APR 01/07

24-32-81

DC GEN CONTROL UNIT


REMOVAL AND INSTALLATION

RAI 10000-002
4

APR07

CLOSE ACCESS DOOR:


- 214BZ
2. REMOVE SAFETY CLIPS AND TAGS AND CLOSE THE
FOLLOWING CIRCUIT BREAKERS:
- ON PANEL 122VU (A)
8PG
15PG
35PU(38PU)
- ON PANEL 124VU (A)
54PU
- ON PANEL 125VU (A)
4PG
13PU(14PU ON PANEL 128VU)
51PU(52PU ON PANEL 128VU)
- ON PANEL 127VU (A)
53PU
006

____________________________________
DC
GEN CONTROL UNIT OPERATIONAL TEST
SEE JOB INSTRUCTION CARD
243281-OPT-10000
*****

AH

E N D

O F

T E X T

*****

24-32-81
RAI 10000-002
2-400 PAGE
4
APR 01/07

24-32-81
5

AH

ACCESS DOORS, C/B PANELS


& SHELVES (90VU - 120VU)

RAI 10000-002
APR07

24-32-81
RAI 10000-002

2-400

PAGE
5
APR 01/07

24-32-81
6

AH

L AND R ELECTRONICS
RACKS 80VU AND 90VU
EQUIPMENT

RAI 10000-002
APR07

24-32-81
RAI 10000-002

2-400

PAGE
6
APR 01/07

24-32-83

DC GEN CONTACTOR
REMOVAL AND INSTALLATION

RAI 10000-001
1

MAR15

ZONING DATA
___________
ZONE
ACCESS

: 212
220
: 212TZ 212VZ 214BZ 214PZ 222CZ 222QZ 222RZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

SPARE

: 02
01
01
01

AH

___
MEN

_________
MAN-HOURS
01

CONTACTOR:11PU-12PU
TERMINAL STRIP: 8PP
TERMINAL STRIP: 7PP
TERMINAL STRIP:13PP

24-32-80-XX-XXX
24-69-80-XX-XXX
24-69-80-XX-XXX
24-69-80-XX-XXX

24-32-83
RAI 10000-001
2-400 PAGE
1
MAR 01/15

24-32-83

DC GEN CONTACTOR
REMOVAL AND INSTALLATION

001

RAI 10000-001
2

MAR15

___________
PREPARATION
REF. FIG. 240000-RAI-00100 (FIG.1)
REF. FIG. 240000-RAI-00103 (FIG.2)
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO THE DC AND AC EXTERNAL POWER RECEPTACLES (ON PANELS 5002VU AND 5000VU
-FIG.1-F AND D) AND THE ACCESS DOORS 114BR
AND 114CR (FIG.1-E AND C) ARE CLOSED
2. ON PANEL 29VU (FIG.1-A) MAKE CERTAIN THAT:
BAT SELECTOR SWITCH 7PA IS IN OFF POSITION
3. DISPLAY A WARNING NOTICE ON PANELS 29VU AND
26VU (FIG.1-B) PROHIBITING POWER SUPPLY TO
SYSTEM
4. ON DC/AC POWER CENTER 120VU OR ON ELECTRONICS RACK 90VU (FIG.2 A AND B AND THE CORRESPONDING FIGURE OF EACH RAI)
120VU: REMOVE ACCESS PANEL 212TZ OR 212VZ
(123VU) OR CIRCUIT BREAKER PANEL 121V
U OR 122VU OR 124VU OR 125VU OR 126VU
OR 127VU OR 128VU OR 129VU OR 130VU
90VU - SIDE SHELF: REMOVE ACCESS PANEL 222RZ
(SHELF 91VU) OR 222QZ (SHELF 91VU OR
92VU OR 93VU) OR 222PZ (SHELF 94VU OR
95VU)
- FRONT SHELF: REMOVE ACCESS PANEL 214
CZ(SHELF 91VU OR 92VU) OR 214BZ(SHELF
93VU OR 94VU OR 95VU)

002

___________________________
REMOVAL
OF DC GEN CONTACTOR
REF.FIG.243213-RAI-00100
1. REMOVE NUTS (3) AND WASHERS (4) TO DISCONNECT THE CONTACTOR (1) FROM TERMINAL STRIPS
8PP (2), 7PP (5) AND 13PP (6)
*** CONTINUED ***
AH

24-32-83
RAI 10000-001
2-400 PAGE
2
MAR 01/15

24-32-83

DC GEN CONTACTOR
REMOVAL AND INSTALLATION

RAI 10000-001
3

MAR15

2. REMOVE CAPTIVE SCREWS (8) TO DISCONNECT THE


ELECTRICAL CONNECTOR (7)
3. REMOVE CONTACTOR WITH CARE TO NOT DAMAGE
THE ELECTRICAL CONNECTOR
003

________________________________
INSTALLATION
OF DC GEN CONTACTOR
REF.FIG.243213-RAI-00100
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/
OR COMPONENT ADJACENT AREA.
2. INSTALL CONTACTOR (1) WITH ITS ELECTRICAL
CONNECTOR (7)
3. TIGHTEN CAPTIVE SCREWS (8)
4. CONNECT CONTACTOR TO TERMINAL STRIPS 8PP
(2), 7PP(5) AND 13PP (6)
5. INSTALL WASHERS (4) AND NUTS (3). TIGHTEN
NUTS (TIGHTENING TORQUE VALUE: 1,65 MDAN /
146 LBF X IN)
NOTE: MARK NUTS (3) WITH RED VARNISH

004

________
CLOSE
UP
REF. FIG. 240000-RAI-00100 (FIG.1)
REF. FIG. 240000-RAI-00103 (FIG.2)
1. ON DC/AC POWER CENTER 12OVU OR ON ELECTRONICS RACK 90VU (FIG.2 A OR B AND THE CORRESPONDING FIGURE OF EACH RAI)
120VU: CLOSE ACCESS PANEL 212TZ OR 212VZ OR
CIRCUIT BREAKER PANEL 121VU OR 122VU
OR 124VU OR 125VU OR 127VU OR 128VU
OR 129VU OR 130VU
90VU - SIDE SHELF: CLOSE ACCESS PANEL 222RZ
OR 222QZ OR 222PZ
*** CONTINUED ***
AH

24-32-83
RAI 10000-001
2-400 PAGE
3
MAR 01/15

24-32-83

DC GEN CONTACTOR
REMOVAL AND INSTALLATION

RAI 10000-001
4

MAR15

- FRONT SHELF: CLOSE ACCESS PANEL 214CZ


OR 214BZ
2. REMOVE THE WARNING NOTICE FROM PANELS 29VU
AND 26VU (FIG.1-A AND B)
005

________________
OPERATIONAL
TEST
THIS TEXT IS NOT APPLICABLE
*****

AH

E N D

O F

T E X T

*****

24-32-83
RAI 10000-001
2-400 PAGE
4
MAR 01/15

24-32-83
5

AH

CONTROLS AND INDICATING

RAI 10000-001
MAR15

24-32-83
RAI 10000-001

2-400

PAGE
5
MAR 01/15

24-32-83
6

AH

ACCESS DOORS, C/B PANELS


& SHELVES (90VU - 120VU)

RAI 10000-001
MAR15

24-32-83
RAI 10000-001

2-400

PAGE
6
MAR 01/15

24-32-83
7

AH

RAI OF DC GEN CONTACTORS

RAI 10000-001
MAR15

24-32-83
RAI 10000-001

2-400

PAGE
7
MAR 01/15

24-32-87

REMOVAL AND INSTALLATION


OF FEEDER OVHT SENSORS

RAI 10000-001
1

MAR15

ZONING DATA
___________
ZONE
ACCESS

: 212
220
: 212TZ 212VZ 214BZ 214PZ 222CZ 222FZ 222KZ 222QZ 222RZ
91VU

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

SPARE

: 04 SENSORS

AH

___
MEN

_________
MAN-HOURS
01

24-32-10-04-010

24-32-87
RAI 10000-001
2-400 PAGE
1
MAR 01/15

24-32-87

REMOVAL AND INSTALLATION


OF FEEDER OVHT SENSORS

001

RAI 10000-001
2

MAR15

___________
PREPARATION
REF. FIG. 240000-RAI-00100 (FIG.1)
REF. FIG. 240000-RAI-00103 (FIG.2)
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO THE DC AND AC EXTERNAL POWER RECEPTACLES (ON PANELS 5002VU AND 5000VU
-FIG.1-F AND D) AND THE ACCESS DOORS 114BR
AND 114CR (FIG.1-E AND C) ARE CLOSED
2. ON PANEL 29VU (FIG.1-A) MAKE CERTAIN THAT:
BAT SELECTOR SWITCH 7PA IS IN OFF POSITION
3. DISPLAY A WARNING NOTICE ON PANELS 29VU AND
26VU (FIG.1-B) PROHIBITING POWER SUPPLY TO
SYSTEM
4. ON DC/AC POWER CENTER 120VU OR ON ELECTRONICS RACK 90VU (FIG.2 A AND B AND THE CORRESPONDING FIGURE OF EACH RAI)
120VU: REMOVE ACCESS PANEL 212TZ OR 212VZ
(123VU) OR CIRCUIT BREAKER PANEL 121V
U OR 122VU OR 124VU OR 125VU OR 126VU
OR 127VU OR 128VU OR 129VU OR 130VU
90VU - SIDE SHELF: REMOVE ACCESS PANEL 222RZ
(SHELF 91VU) OR 222QZ (SHELF 91VU OR
92VU OR 93VU) OR 222PZ (SHELF 94VU OR
95VU)
- FRONT SHELF: REMOVE ACCESS PANEL 214
CZ(SHELF 91VU OR 92VU) OR 214BZ(SHELF
93VU OR 94VU OR 95VU)

002

_______
REMOVAL
REF.FIG.243287-RAI-00100
NOTE: THE REMOVAL AND INSTALLATION OF THESE
SENSORS BEING SIMILAR, ONLY THAT RELEVANT TO 77PU WILL BE DESCRIBED
*** CONTINUED ***
AH

24-32-87
RAI 10000-001
2-400 PAGE
2
MAR 01/15

24-32-87

REMOVAL AND INSTALLATION


OF FEEDER OVHT SENSORS

RAI 10000-001
3

MAR15

01. REMOVE SCREWS (2) AND WASHERS (3) RETAINING


COVER (1)
02. REMOVE COVER
03. REMOVE NUT (11) AND WASHER (10) RETAINING
TERMINAL LUGS (12 AND 13) AND SENSOR (17)
04. REMOVE SCREWS (14) AND WASHERS (15) FOR REMOVE TERMINAL LUGS AND SENSOR
05. DISENGAGE TERMINAL LUGS AND SENSOR FROM
TERMINAL STRIP (18)
06. UNPLUG TWO ELECTRICAL CONNECTORS (4 AND 5)
07. PUT BLANKING CAP ON ELECTRICAL CONNECTORS
08. REMOVE SCREWS (9) AND WASHERS (8) RETAINING
CLAMPS (7)
09. REMOVE CLAMPS
10. REMOVE FEEDER OVHT SENSOR WITH ITS SHEAT
AND ELECTRICAL CONNECTOR
11. SEPARE AND IDENTIFY INDIVIDUALLY THE WIRES
OF ELECTRICAL CONNECTOR
003

____________
INSTALLATION
REF.FIG.243287-RAI-00100
01. CUT SENSOR WIRE TO REQUIRED LENGTH
02. INSTALL SHEATH (6) ON SENSORS WIRES
03. CONNECT SENSOR WIRES TO ELECTRICAL CONNECTOR (5) FOLLOWING IDENTIFICATION DURING
REMOVAL
*** CONTINUED ***
AH

24-32-87
RAI 10000-001
2-400 PAGE
3
MAR 01/15

24-32-87

REMOVAL AND INSTALLATION


OF FEEDER OVHT SENSORS

RAI 10000-001
4

MAR15

04. INSTALL SENSOR (17) AND TERMINAL LUGS (12


AND 13) ON ITS TERMINAL STRIP (18)
05. INSTALL WASHER (10) AND SCREW (11). TIGHTEN
SCREWS (TORQUE VALUE: BETWEEN 2.5 AND 3.5
M.DAN / BETWEEN 222 AND 310 LB.IN.).
06. ATTACH CLAMPS (16) WITH WASHERS (15) AND
SCREWS (14)
07. PLUG IN TWO ELECTRICAL CONNECTORS (5 AND 4)
08. SECURE SENSOR CABLE ROUTE WITH CLAMPS (7)
09. INSTALL WASHERS (8) AND SCREWS (9). TIGHTEN
SCREWS
10. INSTALL COVER (1)
11. INSTALL WASHERS (3) AND SCREWS(2). TIGHTEN
SCREWS
004

________
CLOSE
UP
REF. FIG. 240000-RAI-00100 (FIG.1)
REF. FIG. 240000-RAI-00103 (FIG.2)
1. ON DC/AC POWER CENTER 12OVU OR ON ELECTRONICS RACK 90VU (FIG.2 A OR B AND THE CORRESPONDING FIGURE OF EACH RAI)
120VU: CLOSE ACCESS PANEL 212TZ OR 212VZ OR
CIRCUIT BREAKER PANEL 121VU OR 122VU
OR 124VU OR 125VU OR 127VU OR 128VU
OR 129VU OR 130VU
90VU - SIDE SHELF: CLOSE ACCESS PANEL 222RZ
OR 222QZ OR 222PZ
- FRONT SHELF: CLOSE ACCESS PANEL 214CZ
OR 214BZ
2. REMOVE THE WARNING NOTICE FROM PANELS 29VU
AND 26VU (FIG.1-A AND B)
*** CONTINUED ***
AH

24-32-87
RAI 10000-001
2-400 PAGE
4
MAR 01/15

24-32-87

REMOVAL AND INSTALLATION


OF FEEDER OVHT SENSORS

005

RAI 10000-001
5

MAR15

________________
OPERATIONAL
TEST
THIS TEXT IS NOT APPLICABLE
*****

AH

E N D

O F

T E X T

*****

24-32-87
RAI 10000-001
2-400 PAGE
5
MAR 01/15

24-32-87
6

AH

CONTROLS AND INDICATING

RAI 10000-001
MAR15

24-32-87
RAI 10000-001

2-400

PAGE
6
MAR 01/15

24-32-87
7

AH

ACCESS DOORS, C/B PANELS


& SHELVES (90VU - 120VU)

RAI 10000-001
MAR15

24-32-87
RAI 10000-001

2-400

PAGE
7
MAR 01/15

24-32-87
8

AH

REMOVAL AND INSTALLATION


OF FEEDER OVHT DETECTION
SENSOR

RAI 10000-001
MAR15

24-32-87
RAI 10000-001

2-400

PAGE
8
MAR 01/15

24-40-00

CHECK OF CIRCUIT
BREAKERS

CHK 10000-001
1

MAR14

ZONING DATA
___________
ZONE

: 210

250

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
MECHANIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

AH

24-40-00
CHK 10000-001
2-400 PAGE
1
MAR 01/14

24-40-00

CHECK OF CIRCUIT
BREAKERS

001

CHK 10000-001
2

MAR14

_________________________
CHECK
OF CIRCUIT BREAKERS
REF.FIG.244000-CHK-00100
1. PUSH AND PULL ALL CIRCUIT BREAKERS LOCATED
IN THE FOLLOWING AREAS:
A. FLIGHT COMPARTMENT
- OVERHEAD PANEL 20VU (B): SECTION 21VU
- AC/DC POWER CENTER 120VU (A): SECTIONS
121VU, 122VU, 124VU, 125VU, 126VU,
127VU, 128VU, 129VU AND 130VU
B. AFT PASSENGER COMPT END AND/OR GALLEY
(FLIGHT) ATTENDANT PANEL (C)
2. CHECK THAT THEY ARE NOT MECCANICALLY STUCK
NOTE: DO NOT ENERGIZE THE AIRCRAFT
*****

AH

E N D

O F

T E X T

*****

24-40-00
CHK 10000-001
2-400 PAGE
2
MAR 01/14

24-40-00
3

AH

C/B PANELS

CHK 10000-001
MAR14

24-40-00
CHK 10000-001

2-400

PAGE
3
MAR 01/14

24-40-00

DC AND AC EXTERNAL POWER


SUPPLY

EAD 10000-003
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 114
210
: 114BR 114CR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

GSE

: 01 ELECTRICAL GND PWR UNIT

AH

___
MEN

_________
MAN-HOURS

SEE ITEM SPEC

24-40-00
EAD 10000-003
2-400 PAGE
1
DEC 01/14

24-40-00

DC AND AC EXTERNAL POWER


SUPPLY

001

EAD 10000-003
2

DEC14

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

002

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

_______
WARNING
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
1. BEFORE PROVIDING ELECTRICAL POWER SUPPLY TO
AIRCRAFT MAKE CERTAIN THAT SAFETY RULES MUST
BE OBSERVED.
2. ON (FLIGHT)ATTENDANT PANEL MAKE
CERTAIN THAT:
- P/BSW GND SVCE BUS DC IS
IN RELEASED POSITION.
- P/BSW GND SVCE BUS ACWIS
IN RELEASED POSITION.
3. ON PANEL 29VU MAKE CERTAIN THAT:
- SELECTOR SWITCH BAT IS IN OFF POSITION.
- P/BSW EXT PWR IS IN RELEASED POSITION.
- P/BSW MAIN ELEC PWR/DC SVCE/ULTY BUS 
IS IN RELEASED POSITION.
4. ON PANEL 26VU MAKE CERTAIN THAT:
P/BSW EXT PWR IS IN RELEASED POSITION.

003

___________
PREPARATION
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
REF.FIG.244600-EAD-00110
*** CONTINUED ***
AH

24-40-00
EAD 10000-003
2-400 PAGE
2
DEC 01/14

24-40-00

DC AND AC EXTERNAL POWER


SUPPLY

EAD 10000-003
3

DEC14

REF.FIG.244100-EAD-00110
1. (ONLY IF THE A/C IS ON JACKS) ON PANEL 702VU
PLACE NORM/FLT MODE SWITCH IN FLT POSITION
2. ON PANEL 29VU
PLACE BAT SELECTOR SWITCH IN ON POSITION
AND CHECK THAT:
- TWO ARROW LEGENDS OF BAT TIE CAUTION LIGHT
COME ON
- BUS OFF 1 AND 2 AND INV2 FAULT LEGENDS OF
CAUTION LIGHTS COME ON
- DC BUS1 AND 2 OFF CAUTION LIGHTS COME ON
- SHED AND OFF LEGENDS OF DC SVCE/UTLY BUS
PUSHBUTTON SWITCH COME ON
NOTE: ON AIRCRAFT EQUIPPED WITH GROUND PROXIMITY WARNING SYSTEM (GPWS) WHOOP-WHOOP
-PULL UP WARNING SOUNDS WHEN THE SYSTEM IS ENERGIZED.
3. ON PANEL 26VU CHECK THAT:
ACW BUS1 AND 2 OFF CAUTION LIGHTS COME ON
REF. FIG. 244600-EAD-00110
4. OPEN DOOR 114BR GIVING ACCESS
TO DC EXTERNAL POWER RECEPTACLE
REF. FIG. 244100-EAD-00100
5. OPEN DOOR 114CR GIVING ACCESS
TO AC EXTERNAL POWER RECEPTACLE
REF. FIG. 244600-EAD-00110
6. ON PANEL 5002VU PLUG IN THE
GROUND POWER UNIT PLUG TO RECEPTACLE
REF. FIG. 244100-EAD-00100
*** CONTINUED ***
AH

24-40-00
EAD 10000-003
2-400 PAGE
3
DEC 01/14

24-40-00

DC AND AC EXTERNAL POWER


SUPPLY

EAD 10000-003
4

DEC14

7. ON PANEL 5000VU PLUG IN THE


GROUND POWER UNIT PLUG TO RECEPTACLE
8. START THE GROUND POWER UNIT AND SUPPLY THE
AIRCRAFT BY MEANS OF IT
REF. FIG. 244600-EAD-00110
9. ON PANEL 5002VU CHECK THAT:
- DC CNCTD INDICATOR LIGHT COMES ON
- DC PWR NOT USED INDICATOR LIGHT COMES ON
REF. FIG. 244100-EAD-00100
10. ON PANEL 5000VU CHECK THAT:
- AC CNCTD INDICATOR LIGHT COMES ON
- AC PWR NOT USED INDICATOR LIGHT COMES
ON
004

ENERGIZING OF DC AND AC CONSTANT FREQUENCY


__________________________________________
NETWORKS
________
REF. FIG. 244600-EAD-00100
REF. FIG. 244600-EAD-00110
REF. FIG. 244600-EAD-00100
1. ON PANEL 101VU
A. PLACE ELEC IND SELECTOR SWITCH IN EXT PWR
POSITION
B. VERIFY THAT THE VOLTAGE ON DC VOLTMETER
IS 28V
2. ON PANEL 29VU
A. MAKE CERTAIN THAT:
- AVAIL LEGEND OF EXT PWR PUSHBUTTON
SWITCH COMES ON
- BTC PUSHBUTTON SWITCH IS IN RELEASED POSITION
- OVRD/UNDV PUSHBUTTON SWITCH IS IN
RELEASED POSITION
*** CONTINUED ***
AH

24-40-00
EAD 10000-003
2-400 PAGE
4
DEC 01/14

24-40-00

DC AND AC EXTERNAL POWER


SUPPLY

EAD 10000-003
5

DEC14

B. PRESS EXT PWR PUSHBUTTON SWITCH


- ON LEGEND COMES ON
C. SHED LEGEND OF DC SVCE/UTLY BUS PUSHBUTTON SWITCH GOES OFF
D. CHECK THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH COMES ON
- ALL BUS OFF AND INV FAULT LEGENDS OF
CAUTION LIGHTS GO OFF
- THE TWO ARROW LEGENDS OF BAT TIE CAUTION LIGHT GO OFF
- DC BUS1 AND 2 OFF CAUTION LIGHTS
GO OFF
REF. FIG. 244600-EAD-00110
3. ON PANEL 5002VU CHECK THAT:
DC PWR NOT USED INDICATOR LIGHT GOES
OFF
4. MAKE CERTAIN THAT ELECTRONICS RACK VENTILATION OPERATES CORRECTLY
005

_______________________________________
ENERGIZING
OF AC WILD FREQUENCY NETWORK
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
1. ON PANEL 101VU
A. PLACE ELEC IND SELECTOR SWITCH IN EXT PWR
POSITION
B. VERIFY THAT THE VOLTAGE ON AC VOLTMETER
IS 115V AND THE FREQUENCY 400HZ
C. MAKE CERTAIN THAT ELEC/ACW BTC OPNG
SWITCH IS IN NORM FLT POSITION
2. ON PANEL 26VU
A. MAKE CERTAIN THAT:
- AVAIL LEGEND OF EXT PWR PUSHBUTTON
SWITCH IS ON
- BTC PUSHBUTTON SWITCH IS IN RELEA*** CONTINUED ***
AH

24-40-00
EAD 10000-003
2-400 PAGE
5
DEC 01/14

24-40-00

DC AND AC EXTERNAL POWER


SUPPLY

EAD 10000-003
6

DEC14

SED POSITION
B. PRESS PUSHBUTTON SWITCH
- ON LEGEND COMES ON
C. VERIFY THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH COMES ON
- ACW BUS1 AND 2 CAUTION LIGHTS ARE OFF
REF. FIG. 244100-EAD-00100
3. ON PANEL 5000VU CHECK THAT:
AC PWR NOT USED INDICATOR LIGHT GOES
OFF
006

DE-ENERGIZING OF DC AND AC CONSTANT FREQUENCY


_____________________________________________
NETWORKS
________
REF. FIG. 244600-EAD-00100
REF. FIG. 244600-EAD-00110
REF. FIG. 244600-EAD-00100
1. ON PANEL 29VU
A. RELEASE EXT PWR PUSHBUTTON SWITCH
- ON LEGEND GOES OFF
B. SHED LEGEND OF DC SVCE/UTLY BUS PUSHBUTTON SWITCH COMES ON
C. MAKE CERTAIN THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH GOES OFF
- BUS OFF 1 AND 2 AND INV FAULT2 LEGENDS
OF CAUTION LIGHTS COME ON
- THE TWO ARROW LEGENDS OF BAT TIE CAUTION LIGHT COME ON
- DC BUS1 AND 2 OFF CAUTION LIGHTS
COME ON
REF. FIG. 244600-EAD-00110
2. ON PANEL 5002VU CHECK THAT:
DC PWR NOT USED INDICATOR LIGHT COMES ON
*** CONTINUED ***
AH

24-40-00
EAD 10000-003
2-400 PAGE
6
DEC 01/14

DC AND AC EXTERNAL POWER


SUPPLY

007

24-40-00

EAD 10000-003
7

DEC14

__________________________________________
DE-ENERGIZING
OF AC WILD FREQUENCY NETWORK
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
1. ON PANEL 26VU
A. RELEASE EXT PWR PUSHBUTTON SWITCH
- ON LEGEND GOES OFF
B. VERIFY THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH GOES OFF
- ACW BUS1 AND 2 CAUTION LIGHTS COME ON
REF.FIG.244100-EAD-00100
2. ON PANEL 5000VU CHECK THAT:
AC PWR NOT USED INDICATOR LIGHT COMES ON

008

________
CLOSE
UP
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
REF.FIG.244600-EAD-00110
1. CUT OFF THE EXTERNAL POWERS TO AIRCRAFT AND
SHUT-DOWN THE GROUND POWER UNIT
REF.FIG.244600-EAD-00110
2. ON PANEL 5002VU CHECK THAT:
- DC CNCTD INDICATOR LIGHT GOES OFF
- DC PWR NOT USED INDICATOR LIGHT GOES
OFF
REF.FIG.244100-EAD-00100
3. ON PANEL 5000VU CHECK THAT:
- AC CNCTD INDICATOR LIGHT GOES OFF
- AC PWR NOT USED INDICATOR LIGHT GOES
OFF
*** CONTINUED ***
AH

24-40-00
EAD 10000-003
2-400 PAGE
7
DEC 01/14

24-40-00

DC AND AC EXTERNAL POWER


SUPPLY

EAD 10000-003
8

DEC14

WARNING:IT IS FORBIDDEN TO DISCONNECT THE


GROUND POWER UNIT PLUGS WHEN THE AIRCRAFT IS ENERGIZED AS THESE COULD CAUSE
ARCINGS WHICH WOULD BE DANGEROUS FOR
PERSONNEL OR DAMAGES TO EQUIPMENT
REF.FIG.244600-EAD-00110
4. ON PANEL 5002VU UNPLUG THE GROUND POWER UNIT
PLUG FROM DC EXTERNAL POWER RECEPTACLE
REF.FIG.244100-EAD-00100
5. ON PANEL 5000VU UNPLUG THE GROUND POWER UNIT
PLUG FROM AC EXTERNAL POWER RECEPTACLE
REF.FIG.244600-EAD-00110
6. CLOSE ACCESS DOOR 114BR
REF.FIG.244100-EAD-00100
7. CLOSE ACCESS DOOR 114CR
REF.FIG.244100-EAD-00110
8. ON PANEL 29VU
PLACE BAT SELECTOR SWITCH TO OFF POSITION
9. (ONLY IF THE A/C IS ON JACKS) ON PANEL 702VU
REPLACE NORM/FLT MODE SWITCH IN NORM
POSITION
*****

AH

E N D

O F

T E X T

*****

24-40-00
EAD 10000-003
2-400 PAGE
8
DEC 01/14

24-40-00
9

AH

CONTROLS,INDICATING AND
ACCESS DOOR

EAD 10000-003
DEC14

24-40-00
EAD 10000-003

2-400

PAGE
9
DEC 01/14

24-40-00
10

AH

CONTROLS AND INDICATING

EAD 10000-003
DEC14

24-40-00
EAD 10000-003

2-400

PAGE
10
DEC 01/14

24-40-00
11

AH

CONTROLS AND INDICATING

EAD 10000-003
DEC14

24-40-00
EAD 10000-003

2-400

PAGE
11
DEC 01/14

24-40-00
12

AH

DC EXT PWR, ATTENDANT


AND ACCESS DOOR

EAD 10000-003
DEC14

24-40-00
EAD 10000-003

2-400

PAGE
12
DEC 01/14

24-40-00

DC AND AC EXTERNAL POWER


SUPPLY

EAD 10000-004
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 114
210
: 114BR 114CR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

_________
MAN-HOURS

ELAPSED TIME

GSE

: 01 ELECTRICAL GND PWR UNIT

SEE ITEM SPEC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)

31-63-00-PRO-10000

PUBLICATION
___________
JIC

AH

24-40-00
EAD 10000-004
2-400 PAGE
1
DEC 01/14

24-40-00

DC AND AC EXTERNAL POWER


SUPPLY

001

EAD 10000-004
2

DEC14

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

002

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

003

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

_______
WARNING
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
1. BEFORE PROVIDING ELECTRICAL POWER SUPPLY TO
AIRCRAFT MAKE CERTAIN THAT SAFETY RULES MUST
BE OBSERVED.
2. ON (FLIGHT)ATTENDANT PANEL MAKE
CERTAIN THAT:
- P/BSW GND SVCE BUS DC IS
IN RELEASED POSITION.
- P/BSW GND SVCE BUS ACWIS
IN RELEASED POSITION.
*** CONTINUED ***
AH

24-40-00
EAD 10000-004
2-400 PAGE
2
DEC 01/14

DC AND AC EXTERNAL POWER


SUPPLY

24-40-00

EAD 10000-004
3

DEC14

3. ON PANEL 29VU MAKE CERTAIN THAT:


- SELECTOR SWITCH BAT IS IN OFF POSITION.
- P/BSW EXT PWR IS IN RELEASED POSITION.
- P/BSW MAIN ELEC PWR/DC SVCE/ULTY BUS 
IS IN RELEASED POSITION.
4. ON PANEL 26VU MAKE CERTAIN THAT:
P/BSW EXT PWR IS IN RELEASED POSITION.
004

___________
PREPARATION
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
REF.FIG.244600-EAD-00110
REF.FIG.244100-EAD-00110
1. (ONLY IF THE A/C IS ON JACKS) ON PANEL 702VU
PLACE NORM/FLT MODE SWITCH IN FLT POSITION
2. ON PANEL 29VU
PLACE BAT SELECTOR SWITCH IN ON POSITION
AND CHECK THAT:
- TWO ARROW LEGENDS OF BAT TIE CAUTION LIGHT
COME ON
- BUS OFF FOR AC BUS 1 AND 2 AND INV
FAULT FOR INV 2 CAUTION LIGHTS COME ON
- DC BUS OFF FOR DC BUS 1 AND 2 CAUTION
LIGHTS COME ON
- SHED AND OFF LEGENDS OF DC SVCE/UTLY BUS
PUSHBUTTON SWITCH COME ON
ON MFD UPPER WINDOW, IN ELEC SD PAGE:
- AMBER ARROWS ARE DISPLAYED ON EMER AND
MAIN BAT
- AMBER AC BUS 1 OFF AND AC BUS 2 OFF
SYMBOLS ARE DISPLAYED
- AMBER DC BUS 1 OFF AND DC BUS 2 OFF
SYMBOLS ARE DISPLAYED
- AMBER INV 2 FAULT SYMBOL IS DISPLAYED
- SHED LEGENDS ABOVE UTLY BUS 1 AND 2
*** CONTINUED ***
AH

24-40-00
EAD 10000-004
2-400 PAGE
3
DEC 01/14

24-40-00

DC AND AC EXTERNAL POWER


SUPPLY

EAD 10000-004
4

DEC14

SYMBOLS ARE DISPLAYED.


3. ON PANEL 26VU CHECK THAT:
- ACW BUS OFF FOR ACW BUS 1 AND 2
CAUTION LIGHTS COME ON.
ON MFD UPPER WINDOW, IN ACW/HYD SD PAGE:
- AMBER ACW BUS 1 OFF AND ACW BUS 2 OFF
SYMBOLS ARE DISPLAYED.
REF. FIG. 244600-EAD-00110
4. OPEN DOOR 114BR GIVING ACCESS
TO DC EXTERNAL POWER RECEPTACLE
REF. FIG. 244100-EAD-00100
5. OPEN DOOR 114CR GIVING ACCESS
TO AC EXTERNAL POWER RECEPTACLE
REF. FIG. 244600-EAD-00110
6. ON PANEL 5002VU PLUG IN THE
GROUND POWER UNIT PLUG TO RECEPTACLE
REF. FIG. 244100-EAD-00100
7. ON PANEL 5000VU PLUG IN THE
GROUND POWER UNIT PLUG TO RECEPTACLE
8. START THE GROUND POWER UNIT AND SUPPLY THE
AIRCRAFT BY MEANS OF IT
REF. FIG. 244600-EAD-00110
9. ON PANEL 5002VU CHECK THAT:
- DC CNCTD INDICATOR LIGHT COMES ON
- DC PWR NOT USED INDICATOR LIGHT
COMES ON
REF. FIG. 244100-EAD-00100
*** CONTINUED ***
AH

24-40-00
EAD 10000-004
2-400 PAGE
4
DEC 01/14

24-40-00

DC AND AC EXTERNAL POWER


SUPPLY

EAD 10000-004
5

DEC14

10. ON PANEL 5000VU CHECK THAT:


- AC CNCTD INDICATOR LIGHT COMES ON
- AC PWR NOT USED INDICATOR LIGHT
COMES ON
005

ENERGIZING OF DC AND AC CONSTANT FREQUENCY


__________________________________________
NETWORKS
________
REF. FIG. 244600-EAD-00100
REF. FIG. 244600-EAD-00110
REF. FIG. 244600-EAD-00100
1. ON PANEL 101VU
A. PLACE ELEC IND SELECTOR SWITCH IN EXT PWR
POSITION
B. VERIFY THAT THE VOLTAGE ON DC VOLTMETER
IS 28V
2. ON PANEL 29VU
A. MAKE CERTAIN THAT:
- AVAIL LEGEND OF EXT PWR PUSHBUTTON
SWITCH COMES ON
- BTC PUSHBUTTON SWITCH IS IN RELEASED POSITION
- OVRD/UNDV PUSHBUTTON SWITCH IS IN
RELEASED POSITION
ON MFD UPPER WINDOW, IN ELEC SD PAGE:
- EXT PWR AVAIL SYMBOL IS DISPLAYED
- BTC SYMBOL IS DISPLAYED IN GREEN
WITHOUT FLOW BAR.
B. PRESS EXT PWR PUSHBUTTON SWITCH
- ON LEGEND COMES ON
ON MFD UPPER WINDOW, IN ELEC SD PAGE:
- EXT PWR AVAIL ON SYMBOL IS DISPLAYED
C. SHED LEGEND OF DC SVCE/UTLY BUS PUSHBUTTON SWITCH GOES OFF
CHECK THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH COMES ON
- ALL BUS OFF AND INV FAULT LEGENDS
*** CONTINUED ***
AH

24-40-00
EAD 10000-004
2-400 PAGE
5
DEC 01/14

24-40-00

DC AND AC EXTERNAL POWER


SUPPLY

EAD 10000-004
6

DEC14

OF CAUTION LIGHTS GO OFF


- THE TWO ARROW LEGENDS OF BAT TIE
CAUTION LIGHTS GO OFF
- DC BUS OFF CAUTION LIGHTS GO OFF
GO OFF
ON MFD UPPER WINDOW, IN ELEC SD PAGE:
- SHED LEGENDS ABOVE UTLY BUS 1 AND 2
SYMBOLS ARE NO MORE DISPLAYED
- THE FLOW BAR LEGEND OF BTC SYMBOL
IS DISPLAYED
- GREEN AC BUS 1 AND AC BUS 2 ARE
DISPLAYED
- GREEN DC BUS 1 AND DC BUS 2 ARE
DISPLAYED
- GREEN INV 2 IS DISPLAYED
- AMBER ARROWS ARE NO MORE DISPLAYED ON
EMER AND MAIN BAT.
REF. FIG. 244600-EAD-00110
3. ON PANEL 5002VU CHECK THAT:
DC PWR NOT USED INDICATOR LIGHT GOES
OFF
4. MAKE CERTAIN THAT ELECTRONICS RACK VENTILATION OPERATES CORRECTLY
006

_______________________________________
ENERGIZING
OF AC WILD FREQUENCY NETWORK
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
1. ON PANEL 101VU
A. PLACE ELEC IND SELECTOR SWITCH IN EXT PWR
POSITION
B. VERIFY THAT THE VOLTAGE ON AC VOLTMETER
IS 115V AND THE FREQUENCY 400HZ
C. MAKE CERTAIN THAT ELEC/ACW BTC OPNG
SWITCH IS IN NORM FLT POSITION
2. ON PANEL 26VU
*** CONTINUED ***
AH

24-40-00
EAD 10000-004
2-400 PAGE
6
DEC 01/14

24-40-00

DC AND AC EXTERNAL POWER


SUPPLY

EAD 10000-004
7

DEC14

A. MAKE CERTAIN THAT:


- AVAIL LEGEND OF EXT PWR PUSHBUTTON
SWITCH IS ON
- BTC PUSHBUTTON SWITCH IS IN RELEASED
POSITION
ON MFD UPPER WINDOW, IN ACW/HYD SD PAGE:
- EXT PWR AVAIL SYMBOL IS DISPLAYED
- BTC SYMBOL IS DISPLAYED IN GREEN
WITHOUT FLOW BAR
B. PRESS EXT PXR PUSHBUTTON SWITCH
ON LEGEND COMES ON
C. VERIFY THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH COMES ON
- ACW BUS OFF FOR ACW BUS 1 AND 2
CAUTION LIGHTS GO OFF
ON MFD UPPER WINDOW, IN ACW/HYD SD PAGE:
- EXT PWR AVAIL ON SYMBOLL IS DISPLAYED
- THE FLOW BAR LEGEND ON BTC SYMBOL IS
DISPLAYED
- GREEN ACW BUS 1 AND ACW BUS 2 ARE
DISPLAYED
REF.FIG. 244100-EAD-00100
3. ON PANEL 5000VU CHECK THAT:
AC PWR NOT USED INDICATOR LIGHT GOES
OFF
007

DE-ENERGIZING OF DC AND AC CONSTANT FREQUENCY


_____________________________________________
NETWORKS
________
REF. FIG. 244600-EAD-00100
REF. FIG. 244600-EAD-00110
REF. FIG. 244600-EAD-00100
1. ON PANEL 29VU
A. RELEASE EXT PWR PUSHBUTTON SWITCH
- ON LEGEND GOES OFF
ON MFD UPPER WINDOW, IN ELEC SD PAGE:
*** CONTINUED ***
AH

24-40-00
EAD 10000-004
2-400 PAGE
7
DEC 01/14

DC AND AC EXTERNAL POWER


SUPPLY

24-40-00

EAD 10000-004
8

DEC14

- EXT PWR AVAIL SYMBOL IS DISPLAYED


- BTC SYMBOL IS DISPLAYED IN GREEN
WITHOUT FLOW BAR.
B. SHED LEGEND OF DC SVCE/UTLY BUS
PUSHBUTTON SWITCH COMES ON
MAKE CERTAIN THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH GOES OFF
- BUS OFF FOR AC BUS 1 AND 2 AND INV
FAULT 2 FOR INV 2 CAUTION LIGHTS
COME ON
- THE TWO ARROW LEGENDS OF BAT TIE CAUTION LIGHT COME ON
- DC BUS OFF FOR DC BUS 1 AND 2 CAUTION
LIGHTS COMES ON
ON MFD UPPER WINDOW, IN ELEC SD PAGE:
- AMBER ARROWS ARE DISPLAYED ON EMER
AND MAIN BAT
- AMBER AC BUS 1 OFF AND AC BUS 2
OFF SYMBOLS ARE DISPLAYED
- AMBER DC BUS 1 OFF AND DC BUS 2
OFF SYMBOLS ARE DISPLAYED
- AMBER INV 2 FAULT SYMBOL IS DISPLAYED
- SHED LEGENDS ABOVE UTLY BUS 1
AND 2 SYMBOLS ARE DISPLAYED
REF. FIG. 244600-EAD-00110
2. ON PANEL 5002VU CHECK THAT:
DC PWR NOT USED INDICATOR LIGHT COMES ON
008

__________________________________________
DE-ENERGIZING
OF AC WILD FREQUENCY NETWORK
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
1. ON PANEL 26VU
A. RELEASE EXT PWR PUSHBUTTON SWITCH
ON LEGEND GOES OFF
B. VERIFY THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
*** CONTINUED ***
AH

24-40-00
EAD 10000-004
2-400 PAGE
8
DEC 01/14

DC AND AC EXTERNAL POWER


SUPPLY

24-40-00

EAD 10000-004
9

DEC14

SWITCH GOES OFF


- ACW BUS OFF FOR ACW BUS 1 AND 2
CAUTION LIGHTS COME ON
ON MFD UPPER WINDOW, IN ACW/HYD SD PAGE:
- EXT PWR AVAIL SYMBOL IS DISPLAYED
- BTC SYMBOL IS DISPLAYED IN GREEN
WITHOUT FLOW BAR
- AMBER ACW BUS 1 OFF AND ACW BUS 2
OFF SYMBOLS ARE DISPLAYED
REF. FIG. 244100-EAD-00100
2. ON PANEL 5000VU CHECK THAT:
AC PWR NOT USED INDICATOR LIGHT COMES ON
009

________
CLOSE
UP
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
REF.FIG.244600-EAD-00110
1. CUT OFF THE EXTERNAL POWERS TO AIRCRAFT AND
SHUT-DOWN THE GROUND POWER UNIT
REF.FIG.244600-EAD-00110
2. ON PANEL 5002VU CHECK THAT:
- DC CNCTD INDICATOR LIGHT GOES OFF
- DC PWR NOT USED INDICATOR LIGHT GOES
OFF
REF.FIG.244100-EAD-00100
3. ON PANEL 5000VU CHECK THAT:
- AC CNCTD INDICATOR LIGHT GOES OFF
- AC PWR NOT USED INDICATOR LIGHT GOES
OFF
WARNING:IT IS FORBIDDEN TO DISCONNECT THE
GROUND POWER UNIT PLUGS WHEN THE AIRCRAFT IS ENERGIZED AS THESE COULD CAUSE
*** CONTINUED ***
AH

24-40-00
EAD 10000-004
2-400 PAGE
9
DEC 01/14

24-40-00

DC AND AC EXTERNAL POWER


SUPPLY

EAD 10000-004
10

DEC14

ARCINGS WHICH WOULD BE DANGEROUS FOR


PERSONNEL OR DAMAGES TO EQUIPMENT
REF.FIG.244600-EAD-00110
4. ON PANEL 5002VU UNPLUG THE GROUND POWER UNIT
PLUG FROM DC EXTERNAL POWER RECEPTACLE
REF.FIG.244100-EAD-00100
5. ON PANEL 5000VU UNPLUG THE GROUND POWER UNIT
PLUG FROM AC EXTERNAL POWER RECEPTACLE
REF.FIG.244600-EAD-00110
6. CLOSE ACCESS DOOR 114BR
REF.FIG.244100-EAD-00100
7. CLOSE ACCESS DOOR 114CR
REF.FIG.244100-EAD-00110
8. ON PANEL 29VU
PLACE BAT SELECTOR SWITCH TO OFF POSITION
9. (ONLY IF THE A/C IS ON JACKS) ON PANEL 702VU
REPLACE NORM/FLT MODE SWITCH IN NORM
POSITION
*****

AH

E N D

O F

T E X T

*****

24-40-00
EAD 10000-004
2-400 PAGE
10
DEC 01/14

24-40-00
11

AH

CONTROLS,INDICATING AND
ACCESS DOOR

EAD 10000-004
DEC14

24-40-00
EAD 10000-004

2-400

PAGE
11
DEC 01/14

24-40-00
12

AH

CONTROLS AND INDICATING

EAD 10000-004
DEC14

24-40-00
EAD 10000-004

2-400

PAGE
12
DEC 01/14

24-40-00
13

AH

CONTROLS AND INDICATING

EAD 10000-004
DEC14

24-40-00
EAD 10000-004

2-400

PAGE
13
DEC 01/14

24-40-00
14

AH

DC EXT PWR, ATTENDANT


AND ACCESS DOOR

EAD 10000-004
DEC14

24-40-00
EAD 10000-004

2-400

PAGE
14
DEC 01/14

24-41-00

AC WILD FREQUENCY
EXTERNAL POWER SUPPLY

EAD 10000-003
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 114
210
: 114CR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

___
MEN

_________
MAN-HOURS
01

ELAPSED TIME

GSE

: 01 ELECTRICAL GND PWR UNIT

AH

SEE ITEM SPEC

24-41-00
EAD 10000-003
2-400 PAGE
1
DEC 01/14

24-41-00

AC WILD FREQUENCY
EXTERNAL POWER SUPPLY

001

EAD 10000-003
2

DEC14

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

002

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

_______
WARNING
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
1. THE OPERATION OF AC WILD FREQUENCY EXTERNAL
POWER SUPPLY WITHOUT ANY OTHER DC SOURCES
OPERATING (HOTEL MODE OR DC EXT PWR) CAUSES
THE DISCHARGE OF BOTH MAIN AND EMER
BATTERIES.
2. BEFORE TO PROVIDE ELECTRICAL POWER SUPPLY TO
AIRCRAFT MAKE CERTAIN THAT SAFETY RULES MUST
BE OBSERVED.
3. ON (FLIGHT) ATTENDANT PANEL MAKE CERTAIN
THAT:
- P/BSW GND SVCE BUS ACW IS IN OFF
POSITION.
4. ON PANEL 26VU, MAKE CERTAIN THAT:
- P/BSW EXT PWR IS IN OFF POSITION.
5. ON PANEL 29VU, MAKE CERTAIN THAT:
SELECTOR SWITCH BAT IS IN OFF POSITION.

003

___________
PREPARATION
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
*** CONTINUED ***
AH

24-41-00
EAD 10000-003
2-400 PAGE
2
DEC 01/14

24-41-00

AC WILD FREQUENCY
EXTERNAL POWER SUPPLY

EAD 10000-003
3

DEC14

1. ON PANEL 702VU (ONLY IF THE A/C IS ON JACKS)


PLACE NORM/FLT MODE SWITCH IN FLT POSITION
2. ON PANEL 29VU
A. PLACE BAT SELECTOR SWITCH IN ON POSITION
B. CHECK THAT THE TWO ARROW LEGENDS OF BAT
TIE CAUTION LIGHT COME ON
3. ON PANEL 26VU VERIFY THAT:
- ACW BUS1 AND 2 OFF CAUTION LIGHTS COME ON
- OFF LEGEND OF ACW GEN1 AND 2 PUSHBUTTON
SWITCHES 15XU AND 16XU COME ON
REF.FIG.244100-EAD-00100
4. OPEN DOOR 114CR GIVING ACCESS TO
AC EXTERNAL POWER RECEPTACLE
5. ON PANEL 5000VU PLUG IN THE GROUND
POWER UNIT PLUG TO RECEPTACLE
6. START THE GROUND POWER UNIT AND SUPPLY THE
AIRCRAFT BY MEANS OF IT
7. ON PANEL 5000VU CHECK THAT:
- AC CNCTD INDICATOR LIGHT COMES ON
- AC PWR NOT USED INDICATOR LIGHT COMES ON
004

_______________________________________
ENERGIZING
OF AC WILD FREQUENCY NETWORK
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
1. ON PANEL 101VU
A. PLACE ELEC IND SELECTOR SWITCH IN EXT PWR
POSITION
B. VERIFY THAT THE VOLTAGE ON AC VOLTMETER
IS 115V AND THE FREQUENCY 400HZ
C. MAKE CERTAIN THAT ELEC/ACW BTC OPNG
SWITCH IS IN NORM FLT POSITION
*** CONTINUED ***
AH

24-41-00
EAD 10000-003
2-400 PAGE
3
DEC 01/14

24-41-00

AC WILD FREQUENCY
EXTERNAL POWER SUPPLY

EAD 10000-003
4

DEC14

2. ON PANEL 26VU
A. MAKE CERTAIN THAT:
- AVAIL LEGEND OF EXT PWR PUSHBUTTON
SWITCH IS ON
- BTC PUSHBUTTON SWITCH IS IN RELEASED POSITION
B. PRESS PUSHBUTTON SWITCH
- ON LEGEND COMES ON
C. VERIFY THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH COMES ON
- ACW BUS1 AND 2 CAUTION LIGHTS ARE OFF
REF. FIG. 244100-EAD-00100
3. ON PANEL 5000VU CHECK THAT:
AC PWR NOT USED INDICATOR LIGHT GOES
OFF
005

__________________________________________
DE-ENERGIZING
OF AC WILD FREQUENCY NETWORK
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
1. ON PANEL 26VU
A. RELEASE EXT PWR PUSHBUTTON SWITCH
- ON LEGEND GOES OFF
B. VERIFY THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH GOES OFF
- ACW BUS1 AND 2 CAUTION LIGHTS COME ON
REF.FIG.244100-EAD-00100
2. ON PANEL 5000VU CHECK THAT:
AC PWR NOT USED INDICATOR LIGHT COMES ON

006

________
CLOSE
UP
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
*** CONTINUED ***
AH

24-41-00
EAD 10000-003
2-400 PAGE
4
DEC 01/14

24-41-00

AC WILD FREQUENCY
EXTERNAL POWER SUPPLY

EAD 10000-003
5

DEC14

1. CUT OFF THE EXTERNAL POWER TO AIRCRAFT AND


SHUT-DOWN THE GROUND POWER UNIT
REF.FIG.244100-EAD-00100
2. ON PANEL 5000VU CHECK THAT:
- AC CNCTD INDICATOR LIGHT GOES OFF
- AC PWR NOT USED INDICATOR LIGHT GOES OFF
WARNING:IT IS FORBIDDEN TO UNPLUG THE GROUND
POWER UNIT PLUG WHEN THE AIRCRAFT IS
ENERGIZED AS THIS COULD CAUSE ARGING
WHICH WOULD BE DANGEROUS FOR PERSONNEL, OR DAMAGE TO EQUIPMENT
3. ON PANEL 5000VU UNPLUG THE GROUND POWER
UNIT PLUG FROM AC EXT PWR RECEPTACLE
4. CLOSE ACCESS DOOR 114CR
REF.FIG.244100-EAD-00110
5. ON PANEL 29VU
PLACE BAT SELECTOR SWITCH IN OFF POSITION
6. ON PANEL 702VU (ONLY IF YHE A/C IS ON JACKS)
REPLACE NORM/FLT MODE SWITCH IN NORM
POSITION
*****

AH

E N D

O F

T E X T

*****

24-41-00
EAD 10000-003
2-400 PAGE
5
DEC 01/14

24-41-00
6

AH

CONTROLS,INDICATING AND
ACCESS DOOR

EAD 10000-003
DEC14

24-41-00
EAD 10000-003

2-400

PAGE
6
DEC 01/14

24-41-00
7

AH

CONTROLS AND INDICATING

EAD 10000-003
DEC14

24-41-00
EAD 10000-003

2-400

PAGE
7
DEC 01/14

24-41-00

AC WILD FREQUENCY
EXTERNAL POWER SUPPLY

EAD 10000-004
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 114
210
: 114CR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELECTRIC

_________
MAN-HOURS
01

ELAPSED TIME

GSE

: 01 ELECTRICAL GND PWR UNIT

SEE ITEM SPEC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)

31-63-00-PRO-10000

PUBLICATION
___________
JIC

AH

24-41-00
EAD 10000-004
2-400 PAGE
1
DEC 01/14

24-41-00

AC WILD FREQUENCY
EXTERNAL POWER SUPPLY

001

EAD 10000-004
2

DEC14

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

002

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

003

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

_______
WARNING
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
1. THE OPERATION OF AC WILD FREQUENCY EXTERNAL
POWER SUPPLY WITHOUT ANY OTHER DC SOURCES
OPERATING (HOTEL MODE OR DC EXT PWR) CAUSES
THE DISCHARGE OF BOTH MAIN AND EMER
BATTERIES.
2. BEFORE TO PROVIDE ELECTRICAL POWER SUPPLY TO
AIRCRAFT MAKE CERTAIN THAT SAFETY RULES MUST
BE OBSERVED.
3. ON (FLIGHT) ATTENDANT PANEL MAKE CERTAIN
*** CONTINUED ***
AH

24-41-00
EAD 10000-004
2-400 PAGE
2
DEC 01/14

24-41-00

AC WILD FREQUENCY
EXTERNAL POWER SUPPLY

EAD 10000-004
3

DEC14

THAT:
- P/BSW GND SVCE BUS ACW IS IN OFF
POSITION.
4. ON PANEL 26VU, MAKE CERTAIN THAT:
- P/BSW EXT PWR IS IN OFF POSITION.
5. ON PANEL 29VU, MAKE CERTAIN THAT:
SELECTOR SWITCH BAT IS IN OFF POSITION.
004

___________
PREPARATION
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
1. ON PANEL 702VU (ONLY IF THE A/C IS ON JACKS)
PLACE NORM/FLT MODE SWITCH IN FLT POSITION
2. ON PANEL 29VU
PLACE BAT SELECTOR SWITCH IN ON POSITION
AND CHECK THAT:
- TWO ARROW LEGENDS OF BAT TIE CAUTION LIGHT
COME ON
- BUS OFF FOR AC BUS 1 AND 2 AND INV
FAULT 2 FOR INV 2 CAUTION LIGHTS COME ON
- DC BUS OFF FOR DC BUS 1 AND 2 CAUTION
LIGHTS COME ON
- SHED AND OFF LEGENDS OF DC SVCE/UTLY BUS
PUSHBUTTON SWITCH COME ON
ON MFD UPPER WINDOW, IN ELEC SD PAGE:
- AMBER ARROWS ARE DISPLAYED ON EMER AND
MAIN BAT
- AMBER AC BUS 1 OFF AND AC BUS 2 OFF
SYMBOLS ARE DISPLAYED
- AMBER DC BUS 1 OFF AND DC BUS 2 OFF
SYMBOLS ARE DISPLAYED
- AMBER INV 2 FAULT SYMBOL IS DISPLAYED
- SHED LEGENDS ABOVE UTLY BUS 1 AND 2
SYMBOLS ARE DISPLAYED.
*** CONTINUED ***
AH

24-41-00
EAD 10000-004
2-400 PAGE
3
DEC 01/14

24-41-00

AC WILD FREQUENCY
EXTERNAL POWER SUPPLY

EAD 10000-004
4

DEC14

3. ON PANEL 26VU VERIFY THAT:


ACW BUS OFF FOR ACW BUS 1 AND 2 CAUTION
LIGHTS COME ON
ON MFD UPPER WINDOW, IN ACW/HYD SD PAGE:
- AMBER ACW BUS 1 OFF AND ACW BUS 2 OFF
SYMBOLS ARE DISPLAYED
REF.FIG.244100-EAD-00100
4. OPEN DOOR 114CR GIVING ACCESS TO
AC EXTERNAL POWER RECEPTACLE
5. ON PANEL 5000VU PLUG IN THE GROUND
POWER UNIT PLUG TO RECEPTACLE
6. START THE GROUND POWER UNIT AND SUPPLY THE
AIRCRAFT BY MEANS OF IT
7. ON PANEL 5000VU CHECK THAT:
- AC CNCTD INDICATOR LIGHT COMES ON
- AC PWR NOT USED INDICATOR LIGHT COMES ON
005

_______________________________________
ENERGIZING
OF AC WILD FREQUENCY NETWORK
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
1. ON PANEL 101VU
A. PLACE ELEC IND SELECTOR SWITCH IN EXT PWR
POSITION
B. VERIFY THAT THE VOLTAGE ON AC VOLTMETER
IS 115V AND THE FREQUENCY 400HZ
C. MAKE CERTAIN THAT ELEC/ACW BTC OPNG
SWITCH IS IN NORM FLT POSITION
2. ON PANEL 26VU
A. MAKE CERTAIN THAT:
- AVAIL LEGEND OF EXT PWR PUSHBUTTON
SWITCH IS ON
- BTC PUSHBUTTON SWITCH IS IN RELEASED
*** CONTINUED ***
AH

24-41-00
EAD 10000-004
2-400 PAGE
4
DEC 01/14

24-41-00

AC WILD FREQUENCY
EXTERNAL POWER SUPPLY

EAD 10000-004
5

DEC14

POSITION
ON MFD UPPER WINDOW, IN ACW/HYD SD PAGE:
- EXT PWR AVAIL SYMBOL IS DISPLAYED
- BTC SYMBOL IS DISPLAYED IN GREEN
WITHOUT FLOW BAR
B. PRESS EXT PXR PUSHBUTTON SWITCH
ON LEGEND COMES ON
C. VERIFY THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH COMES ON
- ACW BUS OFF FOR ACW BUS 1 AND 2
CAUTION LIGHTS GO OFF
ON MFD UPPER WINDOW, IN ACW/HYD SD PAGE:
- EXT PWR AVAIL ON SYMBOLL IS DISPLAYED
- THE FLOW BAR LEGEND ON BTC SYMBOL IS
DISPLAYED
- GREEN ACW BUS 1 AND ACW BUS 2 ARE
DISPLAYED
REF.FIG. 244100-EAD-00100
3. ON PANEL 5000VU CHECK THAT:
AC PWR NOT USED INDICATOR LIGHT GOES
OFF
006

__________________________________________
DE-ENERGIZING
OF AC WILD FREQUENCY NETWORK
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
1. ON PANEL 26VU
A. RELEASE EXT PWR PUSHBUTTON SWITCH
ON LEGEND GOES OFF
B. VERIFY THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH GOES OFF
- ACW BUS OFF FOR ACW BUS 1 AND 2
CAUTION LIGHTS COME ON
ON MFD UPPER WINDOW, IN ACW/HYD SD PAGE:
- EXT PWR AVAIL SYMBOL IS DISPLAYED
- BTC SYMBOL IS DISPLAYED IN GREEN
*** CONTINUED ***
AH

24-41-00
EAD 10000-004
2-400 PAGE
5
DEC 01/14

AC WILD FREQUENCY
EXTERNAL POWER SUPPLY

24-41-00

EAD 10000-004
6

DEC14

WITHOUT FLOW BAR


- AMBER ACW BUS 1 OFF AND ACW BUS 2
OFF SYMBOLS ARE DISPLAYED
REF. FIG. 244100-EAD-00100
2. ON PANEL 5000VU CHECK THAT:
AC PWR NOT USED INDICATOR LIGHT COMES ON
007

________
CLOSE
UP
REF.FIG.244100-EAD-00100
REF.FIG.244100-EAD-00110
1. CUT OFF THE EXTERNAL POWER TO AIRCRAFT AND
SHUT-DOWN THE GROUND POWER UNIT
REF.FIG.244100-EAD-00100
2. ON PANEL 5000VU CHECK THAT:
- AC CNCTD INDICATOR LIGHT GOES OFF
- AC PWR NOT USED INDICATOR LIGHT GOES OFF
WARNING:IT IS FORBIDDEN TO UNPLUG THE GROUND
POWER UNIT PLUG WHEN THE AIRCRAFT IS
ENERGIZED AS THIS COULD CAUSE ARGING
WHICH WOULD BE DANGEROUS FOR PERSONNEL, OR DAMAGE TO EQUIPMENT
3. ON PANEL 5000VU UNPLUG THE GROUND POWER
UNIT PLUG FROM AC EXT PWR RECEPTACLE
4. CLOSE ACCESS DOOR 114CR
REF.FIG.244100-EAD-00110
5. ON PANEL 29VU
PLACE BAT SELECTOR SWITCH IN OFF POSITION
6. ON PANEL 702VU (ONLY IF YHE A/C IS ON JACKS)
REPLACE NORM/FLT MODE SWITCH IN NORM
*** CONTINUED ***
AH

24-41-00
EAD 10000-004
2-400 PAGE
6
DEC 01/14

24-41-00

AC WILD FREQUENCY
EXTERNAL POWER SUPPLY

EAD 10000-004
7

DEC14

POSITION
*****

AH

E N D

O F

T E X T

*****

24-41-00
EAD 10000-004
2-400 PAGE
7
DEC 01/14

24-41-00
8

AH

CONTROLS,INDICATING AND
ACCESS DOOR

EAD 10000-004
DEC14

24-41-00
EAD 10000-004

2-400

PAGE
8
DEC 01/14

24-41-00
9

AH

CONTROLS AND INDICATING

EAD 10000-004
DEC14

24-41-00
EAD 10000-004

2-400

PAGE
9
DEC 01/14

24-41-11

REMOVAL AND INSTALLATION


OF AC GROUND POWER
RECEPTACLE 1XG

RAI 10000-001
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 114
: 114CR
212HF

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

SPARE

: 01 RECEPTACLE

244110-55

EXPENDABLE

: 10 NUT

244110-55

BULK MATERIAL : SEALANT (09-001F)

_________
MAN-HOURS

09-001

PUBLICATION
___________
JIC
JIC

: REMOVAL AND INSTALLATION


OF FLIGHT COMPARTMENT
FLOOR COVERING
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

25-13-16-RAI-10000
24-46-00-EAD-10000

24-41-11
RAI 10000-001
2-400 PAGE
1
DEC 01/14

24-41-11

REMOVAL AND INSTALLATION


OF AC GROUND POWER
RECEPTACLE 1XG

001

RAI 10000-001
2

DEC14

____________________________________________
REMOVAL
OF FLIGHT COMPARTMENT FLOOR COVERING
SEE JOB INSTRUCTION CARD
251316-RAI-10000

002

___________
PREPARATION
1. REMOVE ACCESS PANEL 212HF.
2. OPEN DOOR 114CR.

003

_____________________________________
REMOVAL
OF AC GROUND POWER RECEPTACLE
REF. FIG. 244111-RAI-00100
1. REMOVE AND DISCARD NUTS (3) AND WASHERS (2).
REMOVE COVER (5).
2. NOTE THE POSITION OF WIRE AND DISCONNECT
THEM.
3. REMOVE AND DISCARD NUTS (8) AND WASHERS (7).
4. REMOVE SCREWS (1) AND (9) AND REMOVE COVER
(4).
5. REMOVE RECEPTACLE (6).

004

__________________________________________
INSTALLATION
OF AC GROUND POWER RECEPTACLE
REF. FIG. 244111-RAI-00100
1. APPLY PRODUCT 09-001F (REF. AMM 20-31-00)
ON THE BASE OF THE RECEPTACLE (6).
2. INSTALL THE RECEPTACLE (6), COVER (4) AND
SCREWS (1) AND (9).
3. FROM INTERNAL ACCESS, INSTALL WASHERS (7)
AND NUTS (8) AND TIGHTEN NUTS.
4. RECONNECT WIRES FOLLOWING THE POSITION NOTED
DURING REMOVAL
(TIGHTENNING TORQUE VALUE:
- FOR CONTACT WITH A DIAMETER OF 11.07 MM /
0.4358 IN: TIGHTEN AT 0.86 MDAN TO 0.95
MDAN / 76.10 LBF.IN TO 84.07 LBF.IN.
- FOR CONTACT WITH A DIAMETER OF 7.89 MM /
0.3106 IN: TIGHTEN AT 0.21 MDAN TO 0.24
MDAN / 18.58 LBF.IN TO 21.23 LBF.IN.)
5. POSTION THE COVER (5) AND INSTALL WASHERS
*** CONTINUED ***
AH

24-41-11
RAI 10000-001
2-400 PAGE
2
DEC 01/14

24-41-11

REMOVAL AND INSTALLATION


OF AC GROUND POWER
RECEPTACLE 1XG

RAI 10000-001
3

DEC14

(2) AND NUTS (3). TIGHTEN NUTS.


005

________
CLOSE-UP
1. INSTALL ACCESS PANEL 212HF.
2. CLOSE DOOR 114CR.

006

INSTALLATION OF FLIGHT COMPARTMENT FLOOR


________________________________________
COVERING
________
SEE JOB INSTRUCTION CARD
251316-RAI-10000

007

______________________________________________
OPERATIONAL
TEST OF AC GROUND POWER RECEPTACLE
DO AN ENERGIZATION AND DE-ENERGIZATION OF DC
AND AC CONSTANT FREQUENCY EXTERNAL POWER SUPPLY
ACCORDING TO THE FOLLOWING CARDS.

008

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

009

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-41-11
RAI 10000-001
2-400 PAGE
3
DEC 01/14

24-41-11
4

AH

REMOVAL AND INSTALLATION


OF AC GROUND POWER
RECEPTACLE

RAI 10000-001
DEC14

24-41-11
RAI 10000-001

2-400

PAGE
4
DEC 01/14

24-41-83

ACW BUS POWER CONTROL


UNIT OPERATIONAL TEST

OPT 10000-001
1

MAR13

ZONING DATA
___________
ZONE
ACCESS

: 214
: 214BZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELECTRIC
ELAPSED TIME

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: POWER SUPPLY FROM


BATTERIES

AH

24-31-00-EAD-10000

24-41-83
OPT 10000-001
2-400 PAGE
1
MAR 01/13

24-41-83

ACW BUS POWER CONTROL


UNIT OPERATIONAL TEST

001

OPT 10000-001
2

MAR13

___________
PREPARATION
REF. FIG. 240000-RAI-00103
NOTE: BPCU OPERATIONAL TEST CAN BE PERFORMED
ON GROUND WITH THE EXTERNAL POWER NOT
USED.
1. ON R ELECTRONICS RACK 90VU
OPEN ACCESS DOOR 214BZ (B)

002

_________________________________
ENERGIZING
OF SYSTEM FROM BATTERY
SEE JOB INSTRUCTION CARD
243100-EAD-10000

003

___________________________________________
ACW
BUS POWER CONTROL UNIT OPERATIONAL TEST
REF.FIG.244113-OPT-00100
1. ON R ELECTRONICS RACK 90VU SHELF 6
ON ACW BPCU FRONT PANEL (B) PRESS THE CC
SWITCH AND VERIFY THAT THE CC INDICATOR
LIGHT COMES ON. AFTER 7+/-1 SECS, IF ACW
BPCU OPERATES CORRECTLY, CC INDICATOR LIGHT
GOES OFF.
IF A FAILURE IS DETECTED ON ACW BPCU, THE CC
INDICATOR LIGHT REMAINS ON, AS LONG AS CC
SWITCH IS PRESSED.

004

____________________________________
DE-ENERGIZING
OF SYSTEM FROM BATTERY
SEE JOB INSTRUCTION CARD
243100-EAD-10000

005

________
CLOSE
UP
REF. FIG. 240000-RAI-00103
1. ON R ELECTRONICS RACK 90VU
CLOSE ACCESS DOOR 214BZ (B)
*****
AH

E N D

O F

T E X T

*****

24-41-83
OPT 10000-001
2-400 PAGE
2
MAR 01/13

24-41-83
3

AH

ACCESS DOORS AND FRONT


PANEL

OPT 10000-001
MAR13

24-41-83
OPT 10000-001

2-400

PAGE
3
MAR 01/13

24-41-83
4

AH

ACCESS DOORS, C/B PANELS


& SHELVES (90VU - 120VU)

OPT 10000-001
MAR13

24-41-83
OPT 10000-001

2-400

PAGE
4
MAR 01/13

24-41-83

ACW BUS POWER CONTROL


UNIT REMOVAL AND
INSTALLATION

RAI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 210
214
: 122VU 126VU
214AZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: ACW BUS POWER CONTROL


UNIT OPERATIONAL TEST

AH

24-41-83-OPT-10000

24-41-83
RAI 10000-001
2-400 PAGE
1
APR 01/05

24-41-83

ACW BUS POWER CONTROL


UNIT REMOVAL AND
INSTALLATION

001

RAI 10000-001
2

APR05

___________
PREPARATION
REF.FIG.240000-RAI-00103
1. OPEN, SAFETY CLIP AND TAG THE FOLLOWING CIRCUIT BREAKERS:
- ON PANEL 122VU (A)
15XG ACW ELEC PWR/BPCU ACW
19XU ACW ELEC PWR/GCU ACW GEN 1
20XU ACW ELEC PWR/GCU ACW GEN 2
- ON PANEL 126VU (A)
4XG EXT PWR/CTL
2. ON R ELECTRONICS RACK 90VU (B)
OPEN ACCESS DOOR 214BZ

002

REMOVAL OF EQUIPMENT FROM L OR R ELECTRONICS


____________________________________________
RACKS 80VU OR 90VU
__________________
REF. FIG. 310000-RAI-00105
NOTE : THE SHAPE AND QUANTITY OF AFT BACKSHELLS
AS WELL AS THE QUANTITY OF FASTENERS MAY
BE DIFFERENT ACCORDING THE EQUIPMENT.
NEVERTHLESS, THE REMOVAL AND INSTALLATION PROCEDURE IS IDENTICAL.
1. REMOVE CORRESPONDING ACCESS PANEL.
2. UNSCREW KNURLED KNOBS (3) ATTACHING
EQUIPMENT (1) TO RACK (4).
3. PULL EQUIPMENT (1) AND REMOVE FROM ITS
RACK (4).
4. INSTALL PROTECTIVE PLUGS ON EQUIPMENT SIDE
ELECTRICAL CONNECTORS (5).

*** CONTINUED ***


AH

24-41-83
RAI 10000-001
2-400 PAGE
2
APR 01/05

24-41-83

ACW BUS POWER CONTROL


UNIT REMOVAL AND
INSTALLATION

003

RAI 10000-001
3

APR05

INSTALLATION OF EQUIPMENT IN L OR R ELECTRONICS


_______________________________________________
RACKS 80VU OR 90VU
__________________
REF. FIG. 310000-RAI-00105
1. CLEAN AND INSPECT EQUIPMENT (1) AND RACK
(4) INTERFACE AREA.
2. REMOVE PROTECTIVE CAPS INSTALLED ON
EQUIPMENT SIDE ELECTRICAL CONNECTORS (5).
3. INSTALL EQUIPMENT (1) IN ITS RACK (4).
4. BLOCK EQUIPMENT BY MEANS OF ITS KNURLED
ATTACHMENT KNOBS (2) AND (3).

004

________
CLOSE
UP
REF.FIG.240000-RAI-00103
1. ON R ELECTRONICS RACK 90VU (B)
CLOSE ACCESS DOOR 214BZ
2. REMOVE SAFETY CLIPS AND TAGS AND CLOSE THE
FOLLOWING CIRCUIT BREAKERS:
- ON PANEL 122VU (A)
15XG
19XU
20XU
- ON PANEL 126VU (A)
4XG

005

___________________________________________
ACW
BUS POWER CONTROL UNIT OPERATIONAL TEST
SEE JOB INSTRUCTION CARD
244183-OPT-10000
*****

AH

E N D

O F

T E X T

*****

24-41-83
RAI 10000-001
2-400 PAGE
3
APR 01/05

24-41-83
4

AH

ACCESS DOORS, C/B PANELS


& SHELVES (90VU - 120VU)

RAI 10000-001
APR05

24-41-83
RAI 10000-001

2-400

PAGE
4
APR 01/05

24-41-83
5

AH

L AND R ELECTRONICS
RACKS 80VU AND 90VU
EQUIPMENT

RAI 10000-001
APR05

24-41-83
RAI 10000-001

2-400

PAGE
5
APR 01/05

24-42-00

ACW SERVICE BUS EXTERNAL


POWER SUPPLY

EAD 10000-003
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 114
210
: 114CR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

___
MEN

_________
MAN-HOURS
01

ELAPSED TIME

GSE

: 01 ELECTRICAL GND PWR UNIT

AH

SEE ITEM SPEC

24-42-00
EAD 10000-003
2-400 PAGE
1
DEC 01/14

ACW SERVICE BUS EXTERNAL


POWER SUPPLY

001

24-42-00

EAD 10000-003
2

DEC14

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

002

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

_______
WARNING
REF. FIG. 244200-EAD-00100
REF. FIG. 244200-OPT-00100
1. BEFORE AIRCRAFT POWER SUPPLY MAKE CERTAIN
THAT SAFETY RULES MUST BE OBSERVED
2. ON (FLIGHT) ATTENDANT PANEL MAKE CERTAIN
THAT:
- P/BSW GND SVCE BUC ACW IS IN
RELEASED POSITION.
3. ON PANEL 26VU MAKE CERTAIN THAT:
- P/BSW EXT PWR IS IN RELEASED POSITION.
4. ON PANEL 29VU MAKE CERTAIN THAT:
- SELECTOR SWITCH BAT IS IN OFF POSITION.

003

___________
PREPARATION
REF. FIG. 244200-EAD-00100
REF. FIG. 244200-OPT-00100
REF. FIG. 244200-EAD-00100
1. ON PANEL 702VU (ONLY IF THE A/C IS ON JACKS)
PLACE NORM/FLT MODE SWITCH IN FLT POSITION
2. ON PANEL 29VU
*** CONTINUED ***
AH

24-42-00
EAD 10000-003
2-400 PAGE
2
DEC 01/14

24-42-00

ACW SERVICE BUS EXTERNAL


POWER SUPPLY

EAD 10000-003
3

DEC14

PLACE BAT SELECTOR SWITCH IN ON POSITION


REF. FIG. 244200-OPT-00100
3. OPEN DOOR 114CR TO ACCESS TO AC
EXTERNAL POWER RECEPTACLE
4. ON PANEL 5000VU PLUG IN GROUND POWER
UNIT TO RECEPTACLE
5. START THE GROUND POWER UNIT AND SUPPLY THE
AIRCRAFT BY MEANS OF IT
6. ON PANEL 5000VU CHECK THAT:
- AC CNCTD INDICATOR LIGHT COMES ON
- AC PWR NOT USED INDICATOR LIGHT COMES ON
004

_______________________________
ENERGIZATION
OF ACW SERVICE BUS
REF.FIG.244200-EAD-00100
REF.FIG.244200-OPT-00100
1. ON PANEL 101VU
A. PLACE ELEC IND SELECTOR SWITCH TO EXT PWR
POSITION
B. VERIFY THAT THE VOLTAGE ON AC VOLTMETER
IS 115V AND THE FREQUENCY 400HZ
2. ON PANEL 26VU CHECK THAT:
AVAIL LEGEND OF EXT PWR PUSHBUTTON SWITCH
IS ON
3. ON (FLIGHT) ATTENDANT PANEL:
A. CHECK THAT SHED LEGEND OF ACW GND SVCE
BUS PUSHBUTTON SWITCH IS ON
B. PRESS PUSHBUTTON SWITCH
- ON LEGEND COMES ON
- SHED LEGEND GOES OFF
4. ON PANEL 5000VU CHECK THAT:
AC PWR NOT USED INDICATOR LIGHT GOES OFF
*** CONTINUED ***
AH

24-42-00
EAD 10000-003
2-400 PAGE
3
DEC 01/14

24-42-00

ACW SERVICE BUS EXTERNAL


POWER SUPPLY

005

EAD 10000-003
4

DEC14

__________________________________
DE-ENERGIZATION
OF ACW SERVICE BUS
REF.FIG.244200-OPT-00100
1. ON (FLIGHT) ATTENDANT PANEL:
RELEASE ACW GND SVCE BUS PUSHBUTTON SWITCH
- SHED LEGEND COMES ON
- ON LEGEND GOES OFF
2. ON PANEL 5000VU CHECK THAT:
AC PWR NOT USED INDICATOR LIGHT COMES ON

006

________
CLOSE
UP
REF.FIG.244200-EAD-00100
REF.FIG.244200-OPT-00100
1. CUT OFF THE EXTERNAL POWER TO AIRCRAFT AND
SHUT-DOWN THE GROUND POWER UNIT
REF.FIG.244200-OPT-00100
2. ON PANEL 5000VU CHECK THAT:
- AC CNCTD INDICATOR LIGHT GOES OFF
- AC PWR NOT USED INDICATOR LIGHT GOES OFF
WARNING: IT IS FORBIDDEN TO UNPLUG THE GROUND
POWER UNIT PLUG WHEN THE AIRCRAFT IS
ENERGIZED AS THIS COULD CAUSE ARCING
WHICH WOULD BE DANGEROUS FOR PERSONNEL OR DAMAGE TO EQUIPMENT
3. ON PANEL 5000VU UNPLUG THE GROUND POWER UNIT
PLUG FROM AC EXT PWR RECEPTACLE
4. CLOSE ACCESS DOOR 114CR
REF.FIG.244200-EAD-00100
5. ON PANEL 702VU (ONLY IF THE A/C IS ON JACKS)
REPLACE NORM/FLT MODE SWITCH IN NORM
*** CONTINUED ***
AH

24-42-00
EAD 10000-003
2-400 PAGE
4
DEC 01/14

24-42-00

ACW SERVICE BUS EXTERNAL


POWER SUPPLY

EAD 10000-003
5

DEC14

POSITION
*****

AH

E N D

O F

T E X T

*****

24-42-00
EAD 10000-003
2-400 PAGE
5
DEC 01/14

24-42-00
6

AH

CONTROLS,INDICATING AND
ACCESS DOOR

EAD 10000-003
DEC14

24-42-00
EAD 10000-003

2-400

PAGE
6
DEC 01/14

24-42-00
7

AH

CONTROLS AND INDICATING

EAD 10000-003
DEC14

24-42-00
EAD 10000-003

2-400

PAGE
7
DEC 01/14

24-42-00

ACW SERVICE BUS EXTERNAL


POWER SUPPLY

EAD 10000-004
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 114
210
: 114CR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

___
MEN

_________
MAN-HOURS
01

ELAPSED TIME

GSE

: 01 ELECTRICAL GND PWR UNIT

AH

SEE ITEM SPEC

24-42-00
EAD 10000-004
2-400 PAGE
1
DEC 01/14

ACW SERVICE BUS EXTERNAL


POWER SUPPLY

001

24-42-00

EAD 10000-004
2

DEC14

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

002

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

_______
WARNING
REF. FIG. 244200-EAD-00100
REF. FIG. 244200-OPT-00100
1. BEFORE AIRCRAFT POWER SUPPLY MAKE CERTAIN
THAT SAFETY RULES MUST BE OBSERVED
2. ON (FLIGHT) ATTENDANT PANEL MAKE CERTAIN
THAT:
- P/BSW GND SVCE BUC ACW IS IN
RELEASED POSITION.
3. ON PANEL 26VU MAKE CERTAIN THAT:
- P/BSW EXT PWR IS IN RELEASED POSITION.
4. ON PANEL 29VU MAKE CERTAIN THAT:
- SELECTOR SWITCH BAT IS IN OFF POSITION.

003

___________
PREPARATION
REF. FIG. 244200-EAD-00100
REF. FIG. 244200-OPT-00100
REF. FIG. 244200-EAD-00100
1. ON PANEL 702VU (ONLY IF THE A/C IS ON JACKS)
PLACE NORM/FLT MODE SWITCH IN FLT POSITION
2. ON PANEL 29VU
*** CONTINUED ***
AH

24-42-00
EAD 10000-004
2-400 PAGE
2
DEC 01/14

24-42-00

ACW SERVICE BUS EXTERNAL


POWER SUPPLY

EAD 10000-004
3

DEC14

PLACE BAT SELECTOR SWITCH IN ON POSITION


REF. FIG. 244200-OPT-00100
3. OPEN DOOR 114CR TO ACCESS TO AC
EXTERNAL POWER RECEPTACLE
4. ON PANEL 5000VU PLUG IN GROUND POWER
UNIT TO RECEPTACLE
5. START THE GROUND POWER UNIT AND SUPPLY THE
AIRCRAFT BY MEANS OF IT
6. ON PANEL 5000VU CHECK THAT:
- AC CNCTD INDICATOR LIGHT COMES ON
- AC PWR NOT USED INDICATOR LIGHT COMES ON
004

_______________________________
ENERGIZATION
OF ACW SERVICE BUS
REF.FIG.244200-EAD-00100
REF.FIG.244200-OPT-00100
1. ON PANEL 101VU
A. PLACE ELEC IND SELECTOR SWITCH TO EXT PWR
POSITION
B. VERIFY THAT THE VOLTAGE ON AC VOLTMETER
IS 115V AND THE FREQUENCY 400HZ
2. ON PANEL 26VU CHECK THAT:
AVAIL LEGEND OF EXT PWR PUSHBUTTON SWITCH
IS ON
3. ON (FLIGHT) ATTENDANT PANEL:
A. CHECK THAT SHED LEGEND OF ACW GND SVCE
BUS PUSHBUTTON SWITCH IS ON
B. PRESS PUSHBUTTON SWITCH
- ON LEGEND COMES ON
- SHED LEGEND GOES OFF
4. ON PANEL 5000VU CHECK THAT:
AC PWR NOT USED INDICATOR LIGHT GOES OFF
*** CONTINUED ***
AH

24-42-00
EAD 10000-004
2-400 PAGE
3
DEC 01/14

24-42-00

ACW SERVICE BUS EXTERNAL


POWER SUPPLY

005

EAD 10000-004
4

DEC14

__________________________________
DE-ENERGIZATION
OF ACW SERVICE BUS
REF.FIG.244200-OPT-00100
1. ON (FLIGHT) ATTENDANT PANEL:
RELEASE ACW GND SVCE BUS PUSHBUTTON SWITCH
- SHED LEGEND COMES ON
- ON LEGEND GOES OFF
2. ON PANEL 5000VU CHECK THAT:
AC PWR NOT USED INDICATOR LIGHT COMES ON

006

________
CLOSE
UP
REF.FIG.244200-EAD-00100
REF.FIG.244200-OPT-00100
1. CUT OFF THE EXTERNAL POWER TO AIRCRAFT AND
SHUT-DOWN THE GROUND POWER UNIT
REF.FIG.244200-OPT-00100
2. ON PANEL 5000VU CHECK THAT:
- AC CNCTD INDICATOR LIGHT GOES OFF
- AC PWR NOT USED INDICATOR LIGHT GOES OFF
WARNING: IT IS FORBIDDEN TO UNPLUG THE GROUND
POWER UNIT PLUG WHEN THE AIRCRAFT IS
ENERGIZED AS THIS COULD CAUSE ARCING
WHICH WOULD BE DANGEROUS FOR PERSONNEL OR DAMAGE TO EQUIPMENT
3. ON PANEL 5000VU UNPLUG THE GROUND POWER UNIT
PLUG FROM AC EXT PWR RECEPTACLE
4. CLOSE ACCESS DOOR 114CR
REF.FIG.244200-EAD-00100
5. ON PANEL 702VU (ONLY IF THE A/C IS ON JACKS)
REPLACE NORM/FLT MODE SWITCH IN NORM
*** CONTINUED ***
AH

24-42-00
EAD 10000-004
2-400 PAGE
4
DEC 01/14

24-42-00

ACW SERVICE BUS EXTERNAL


POWER SUPPLY

EAD 10000-004
5

DEC14

POSITION
*****

AH

E N D

O F

T E X T

*****

24-42-00
EAD 10000-004
2-400 PAGE
5
DEC 01/14

24-42-00
6

AH

CONTROLS, INDICATING AND


ACCESS DOOR

EAD 10000-004
DEC14

24-42-00
EAD 10000-004

2-400

PAGE
6
DEC 01/14

24-42-00
7

AH

CONTROLS AND INDICATING

EAD 10000-004
DEC14

24-42-00
EAD 10000-004

2-400

PAGE
7
DEC 01/14

24-42-00

ACW SERVICE BUS TRANSFER


RELAYS OPERATIONAL TEST

OPT 10000-001
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 114
210
: 114CR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

___
MEN

_________
MAN-HOURS
01

ELAPSED TIME

GSE

: 01 ELECTRICAL GND PWR UNIT

AH

SEE ITEM SPEC

24-42-00
OPT 10000-001
2-400 PAGE
1
DEC 01/14

ACW SERVICE BUS TRANSFER


RELAYS OPERATIONAL TEST

001

24-42-00

OPT 10000-001
2

DEC14

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

002

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

_______
WARNING
REF. FIG. 244200-EAD-00100
REF. FIG. 244200-OPT-00100
1. BEFORE AIRCRAFT POWER SUPPLY MAKE CERTAIN
THAT SAFETY RULES MUST BE OBSERVED
2. ON (FLIGHT) ATTENDANT PANEL MAKE CERTAIN
THAT:
- P/BSW GND SVCE BUC ACW IS IN
RELEASED POSITION.
3. ON PANEL 26VU MAKE CERTAIN THAT:
- P/BSW EXT PWR IS IN RELEASED POSITION.
4. ON PANEL 29VU MAKE CERTAIN THAT:
- SELECTOR SWITCH BAT IS IN OFF POSITION.

003

___________
PREPARATION
REF. FIG. 244200-EAD-00100
REF. FIG. 244200-OPT-00100
REF. FIG. 244200-EAD-00100
1. ON PANEL 702VU (ONLY IF THE A/C IS ON JACKS)
PLACE NORM/FLT MODE SWITCH IN FLT POSITION
2. ON PANEL 29VU
*** CONTINUED ***
AH

24-42-00
OPT 10000-001
2-400 PAGE
2
DEC 01/14

24-42-00

ACW SERVICE BUS TRANSFER


RELAYS OPERATIONAL TEST

OPT 10000-001
3

DEC14

PLACE BAT SELECTOR SWITCH IN ON POSITION


REF. FIG. 244200-OPT-00100
3. OPEN DOOR 114CR TO ACCESS TO AC
EXTERNAL POWER RECEPTACLE
4. ON PANEL 5000VU PLUG IN GROUND POWER
UNIT TO RECEPTACLE
5. START THE GROUND POWER UNIT AND SUPPLY THE
AIRCRAFT BY MEANS OF IT
6. ON PANEL 5000VU CHECK THAT:
- AC CNCTD INDICATOR LIGHT COMES ON
- AC PWR NOT USED INDICATOR LIGHT COMES ON
004

______________________
OPERATIONAL
TEST (2XX)
REF.FIG.244200-EAD-00100
REF.FIG.244200-OPT-00100
1. ON PANEL 101VU
A. PLACE ELEC IND SELECTOR SWITCH TO EXT
PWR POSITION.
B. VERIFY THAT THE VOLTAGE ON AC VOLTMETER
IS 115V AND THE FREQUENCY IS 400HZ.
2. ON PANEL 26VU CHECK THAT:
AVAIL LEGEND OF EXT PWR PUSHBUTTON SWITCH
IS ON.
3. ON (FLIGHT) ATTENDANT PANEL:
A. CHECK THAT SHED LEGEND OF P/BSW GND
SVCE BUS ACW IS ON.
B. PRESS P/BSW GND SVCE BUS ACW
AND CHECK THAT:
- ON LEGEND COMES ON
- SHED LEGEND IS GOES OFF
4. ON PANEL 5000VU VERIFY THAT:
*** CONTINUED ***
AH

24-42-00
OPT 10000-001
2-400 PAGE
3
DEC 01/14

24-42-00

ACW SERVICE BUS TRANSFER


RELAYS OPERATIONAL TEST

OPT 10000-001
4

DEC14

AC PWR NOT USED INDICATOR LIGHT GOES OFF


5. ON PANEL 126VU
OPEN THE FOLLOWING CIRCUIT BREAKER:
1XX EXT PWR/ACW/SVCE BUS ON EXT PWR
6. ON (FLIGHT) ATTENDANT PANEL VERIFY THAT:
SHED LEGEND OF P/BSW GND SVCE BUS ACW
COMES ON.
7. ON PANEL 5000VU CHECK THAT:
INDICATOR LIGHT IS STILL OFF.
8. ON PANEL 126VU
CLOSE THE FOLLOWING CIRCUIT BREAKER:
1XX
005

______________________
OPERATIONAL
TEST (8XX)
REF. FIG. 244200-EAD-00100
REF. FIG. 244200-OPT-00100
1. ON PANEL 101VU
A. PLACE ELEC IND SELECTOR SWITCH TO EXT
PWR POSITION
B. VERIFY THAT THE VOLTAGE ON AC VOLTMETER
IS 115V AND THE FREQUENCY IS 400HZ
2. ON (FLIGHT) ATTENDANT PANEL VERIFY THAT
SHED LEGEND OF P/BSW GND SVCE BUS ACW
IS ON.
3. ON PANEL 26VU
A. CHECK THAT AVAIL LEGEND OF EXT PWR PUSHBUTTON SWITCH IS ON.
B. PRESS PUSHBUTTON SWITCH
- ON LEGEND COMES ON.
4. ON PANEL 5000VU, CHECK THAT:
AC PWR NOT USED INDICATOR LIGHT GOES OFF.
*** CONTINUED ***
AH

24-42-00
OPT 10000-001
2-400 PAGE
4
DEC 01/14

24-42-00

ACW SERVICE BUS TRANSFER


RELAYS OPERATIONAL TEST

OPT 10000-001
5

DEC14

5. ON (FLIGHT) ATTENDANT PANEL


A. CHECK THAT SHED LEGEND OF P/BSW GND
SVCE BUS ACW IS ON.
B. PRESS P/BSW GND SVCE BUS ACW
AND CHECK THAT:
- ON LEGEND COMES ON
- SHED LEGEND GOES OFF
6. ON PANEL 126VU
OPEN THE FOLLOWING CIRCUIT BREAKER:
5XX PWR SUPPLY ON PRIM ACW BUS1/ACW/SVCE BUS
7. ON (FLIGHT) ATTENDANT PANEL CHECK THAT:
SHED LEGEND OF P/BSW GND SVCE BUS ACW
COMES ON
8. ON PANEL 5000VU CHECK THAT:
INDICATOR LIGHT IS STILL OFF.
9. ON PANEL 126VU
CLOSE THE FOLLOWING CIRCUIT BREAKER:
5XX
006

________
CLOSE
UP
REF.FIG.244200-EAD-00100
REF.FIG.244200-OPT-00100
1. CUT OFF THE EXTERNAL POWER TO AIRCRAFT AND
SHUT-DOWN THE GROUND POWER UNIT
REF.FIG.244200-OPT-00100
2. ON PANEL 5000VU CHECK THAT:
- AC CNCTD INDICATOR LIGHT GOES OFF
- AC PWR NOT USED INDICATOR LIGHT GOES OFF
WARNING: IT IS FORBIDDEN TO UNPLUG THE GROUND
POWER UNIT PLUG WHEN THE AIRCRAFT IS
ENERGIZED AS THIS COULD CAUSE ARCING
WHICH WOULD BE DANGEROUS FOR PERSON*** CONTINUED ***
AH

24-42-00
OPT 10000-001
2-400 PAGE
5
DEC 01/14

24-42-00

ACW SERVICE BUS TRANSFER


RELAYS OPERATIONAL TEST

OPT 10000-001
6

DEC14

NEL OR DAMAGE TO EQUIPMENT


3. ON PANEL 5000VU UNPLUG THE GROUND POWER UNIT
PLUG FROM AC EXT PWR RECEPTACLE
4. CLOSE ACCESS DOOR 114CR
REF.FIG.244200-EAD-00100
5. ON PANEL 702VU (ONLY IF THE A/C IS ON JACKS)
REPLACE NORM/FLT MODE SWITCH IN NORM
POSITION
*****

AH

E N D

O F

T E X T

*****

24-42-00
OPT 10000-001
2-400 PAGE
6
DEC 01/14

24-42-00
7

AH

CONTROLS,INDICATING AND
ACCESS DOOR

OPT 10000-001
DEC14

24-42-00
OPT 10000-001

2-400

PAGE
7
DEC 01/14

24-42-00
8

AH

CONTROLS AND INDICATING

OPT 10000-001
DEC14

24-42-00
OPT 10000-001

2-400

PAGE
8
DEC 01/14

24-42-00

ACW SERVICE BUS TRANSFER


RELAYS OPERATIONAL TEST

OPT 10000-002
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 114
210
: 114CR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

___
MEN

_________
MAN-HOURS
01

ELAPSED TIME

GSE

: 01 ELECTRICAL GND PWR UNIT

AH

SEE ITEM SPEC

24-42-00
OPT 10000-002
2-400 PAGE
1
DEC 01/14

ACW SERVICE BUS TRANSFER


RELAYS OPERATIONAL TEST

001

24-42-00

OPT 10000-002
2

DEC14

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

002

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

_______
WARNING
REF. FIG. 244200-EAD-00100
REF. FIG. 244200-OPT-00100
1. BEFORE AIRCRAFT POWER SUPPLY MAKE CERTAIN
THAT SAFETY RULES MUST BE OBSERVED
2. ON (FLIGHT) ATTENDANT PANEL MAKE CERTAIN
THAT:
- P/BSW GND SVCE BUC ACW IS IN
RELEASED POSITION.
3. ON PANEL 26VU MAKE CERTAIN THAT:
- P/BSW EXT PWR IS IN RELEASED POSITION.
4. ON PANEL 29VU MAKE CERTAIN THAT:
- SELECTOR SWITCH BAT IS IN OFF POSITION.

003

___________
PREPARATION
REF. FIG. 244200-EAD-00100
REF. FIG. 244200-OPT-00100
REF. FIG. 244200-EAD-00100
1. ON PANEL 702VU (ONLY IF THE A/C IS ON JACKS)
PLACE NORM/FLT MODE SWITCH IN FLT POSITION
2. ON PANEL 29VU
*** CONTINUED ***
AH

24-42-00
OPT 10000-002
2-400 PAGE
2
DEC 01/14

24-42-00

ACW SERVICE BUS TRANSFER


RELAYS OPERATIONAL TEST

OPT 10000-002
3

DEC14

PLACE BAT SELECTOR SWITCH IN ON POSITION


REF. FIG. 244200-OPT-00100
3. OPEN DOOR 114CR TO ACCESS TO AC
EXTERNAL POWER RECEPTACLE
4. ON PANEL 5000VU PLUG IN GROUND POWER
UNIT TO RECEPTACLE
5. START THE GROUND POWER UNIT AND SUPPLY THE
AIRCRAFT BY MEANS OF IT
6. ON PANEL 5000VU CHECK THAT:
- AC CNCTD INDICATOR LIGHT COMES ON
- AC PWR NOT USED INDICATOR LIGHT COMES ON
004

______________________
OPERATIONAL
TEST (2XX)
REF.FIG.244200-EAD-00100
REF.FIG.244200-OPT-00100
1. ON PANEL 101VU
A. PLACE ELEC IND SELECTOR SWITCH TO EXT
PWR POSITION.
B. VERIFY THAT THE VOLTAGE ON AC VOLTMETER
IS 115V AND THE FREQUENCY IS 400HZ.
2. - ON PANEL 26VU CHECK THAT:
AVAIL LEGEND OF EXT PWR PUSHBUTTON
SWITCH IS ON.
- ON MFD UPPER WINDOW, IN ACW/HYD SD PAGE,
EXT PWR AVAIL SYMBOL IS DISPLAYED.
3. ON (FLIGHT) ATTENDANT PANEL
A. CHECK THAT SHED LEGEND OF P/BSW GND
SVCE BUS ACW IS ON.
B. PRESS P/BSW GND SVCE BUS ACW
AND CHECK THAT:
- ON LEGEND COMES ON
- SHED LEGEND IS GOES OFF
*** CONTINUED ***
AH

24-42-00
OPT 10000-002
2-400 PAGE
3
DEC 01/14

24-42-00

ACW SERVICE BUS TRANSFER


RELAYS OPERATIONAL TEST

OPT 10000-002
4

DEC14

4. ON PANEL 5000VU VERIFY THAT:


AC PWR NOT USED INDICATOR LIGHT GOES OFF
5. ON PANEL 126VU
OPEN THE FOLLOWING CIRCUIT BREAKER:
1XX EXT PWR/ACW/SVCE BUS ON EXT PWR
6. ON (FLIGHT) ATTENDANT PANEL VERIFY THAT:
SHED LEGEND OF P/BSW GND SVCE BUS ACW
COMES ON.
7. ON PANEL 5000VU CHECK THAT:
AC PWR NOT USED INDICATOR LIGHT IS STILL
OFF.
8. ON PANEL 126VU
CLOSE THE FOLLOWING CIRCUIT BREAKER:
1XX
005

______________________
OPERATIONAL
TEST (8XX)
REF. FIG. 244200-EAD-00100
REF. FIG. 244200-OPT-00100
1. ON PANEL 101VU
A. PLACE ELEC IND SELECTOR SWITCH TO EXT
PWR POSITION
B. VERIFY THAT THE VOLTAGE ON AC VOLTMETER
IS 115V AND THE FREQUENCY IS 400HZ
2. ON (FLIGHT) ATTENDANT PANEL CHECK THAT:
SHED LEGEND OF P/BSW GND SVCE BUS ACW
IS ON.
3. ON PANEL 26VU
A. CHECK THAT AVAIL LEGEND OF EXT PWR
BUTTON SWITCH IS ON.
B. PRESS EXT PWR PUSHBUTTON SWITCH
- ON LEGEND COMES ON.
ON MFD UPPER WINDOW, IN ACW/HYD SD PAGE,
EXT PWR AVAIL ON SYMBOL IS DISPLAYED.
*** CONTINUED ***
AH

24-42-00
OPT 10000-002
2-400 PAGE
4
DEC 01/14

24-42-00

ACW SERVICE BUS TRANSFER


RELAYS OPERATIONAL TEST

OPT 10000-002
5

DEC14

4. ON PANEL 5000VU, CHECK THAT:


AC PWR NOT USED INDICATOR LIGHT GOES OFF.
5. ON (FLIGHT) ATTENDANT PANEL
A. CHECK THAT SHED LEGEND OF P/BSW GND
SVCE BUS ACW IS ON.
B. PRESS P/BSW GND SVCE BUS ACW
AND CHECK THAT:
- ON LEGEND COMES ON
- SHED LEGEND GOES OFF
6. ON PANEL 126VU
OPEN THE FOLLOWING CIRCUIT BREAKER:
5XX PWR SUPPLY ON PRIM ACW BUS1/ACW/SVCE BUS
7. ON (FLIGHT) ATTENDANT PANEL CHECK THAT:
SHED LEGEND OF P/BSW GND SVCE BUS ACW
COMES ON
8. ON PANEL 5000VU CHECK THAT:
AC PWR NOT USED INDICATOR LIGHT IS STILL
OFF.
9. ON PANEL 126VU
CLOSE THE FOLLOWING CIRCUIT BREAKER:
5XX
006

________
CLOSE
UP
REF.FIG.244200-EAD-00100
REF.FIG.244200-OPT-00100
1. CUT OFF THE EXTERNAL POWER TO AIRCRAFT AND
SHUT-DOWN THE GROUND POWER UNIT
REF.FIG.244200-OPT-00100
2. ON PANEL 5000VU CHECK THAT:
- AC CNCTD INDICATOR LIGHT GOES OFF
- AC PWR NOT USED INDICATOR LIGHT GOES OFF
*** CONTINUED ***
AH

24-42-00
OPT 10000-002
2-400 PAGE
5
DEC 01/14

24-42-00

ACW SERVICE BUS TRANSFER


RELAYS OPERATIONAL TEST

OPT 10000-002
6

DEC14

WARNING: IT IS FORBIDDEN TO UNPLUG THE GROUND


POWER UNIT PLUG WHEN THE AIRCRAFT IS
ENERGIZED AS THIS COULD CAUSE ARCING
WHICH WOULD BE DANGEROUS FOR PERSONNEL OR DAMAGE TO EQUIPMENT
3. ON PANEL 5000VU UNPLUG THE GROUND POWER UNIT
PLUG FROM AC EXT PWR RECEPTACLE
4. CLOSE ACCESS DOOR 114CR
REF.FIG.244200-EAD-00100
5. ON PANEL 702VU (ONLY IF THE A/C IS ON JACKS)
REPLACE NORM/FLT MODE SWITCH IN NORM
POSITION
*****

AH

E N D

O F

T E X T

*****

24-42-00
OPT 10000-002
2-400 PAGE
6
DEC 01/14

24-42-00
7

AH

CONTROLS, INDICATING AND


ACCESS DOOR

OPT 10000-002
DEC14

24-42-00
OPT 10000-002

2-400

PAGE
7
DEC 01/14

24-42-00
8

AH

CONTROLS AND INDICATING

OPT 10000-002
DEC14

24-42-00
OPT 10000-002

2-400

PAGE
8
DEC 01/14

24-46-00

DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

EAD 10000-003
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 114
210
: 114BR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

___
MEN

_________
MAN-HOURS
01

ELAPSED TIME

GSE

: 01 ELECTRICAL GND PWR UNIT

AH

SEE ITEM SPEC

24-46-00
EAD 10000-003
2-400 PAGE
1
DEC 01/14

DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

001

24-46-00

EAD 10000-003
2

DEC14

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

002

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

_______
WARNING
REF.FIG.244600-EAD-00100
1. BEFORE AIRCRAFT POWER SUPPLY MAKE CERTAIN
THAT SAFETY RULES MUST BE OBSERVED
2. ON PANEL 29VU MAKE CERTAIN THAT:
- BAT SELECTOR SWITCH IS IN OFF POSITION
- EXT PWR PUSHBUTTON SWITCH IS IN
RELEASED POSITION

003

___________
PREPARATION
REF.FIG.244600-EAD-00100
REF.FIG.244600-EAD-00110
REF.FIG.244600-EAD-00100
(ONLY IF THE A/C IS ON JACKS)
1. ON PANEL 702VU
PLACE NORM/FLT MODE SWITCH IN FLT POSITION
2. ON PANEL 29VU
PLACE BAT SELECTOR SWITCH IN ON POSITION
AND VERIFY THAT:
- THE TWO ARROW LEGENDS OF BAT TIE CAUTION
LIGHT COME ON
- BUS OFF 1 AND 2 LEGENDS OF CAUTION LIGHTS
COME ON AND AFTER ABOUT 5 SECS
*** CONTINUED ***
AH

24-46-00
EAD 10000-003
2-400 PAGE
2
DEC 01/14

24-46-00

DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

EAD 10000-003
3

DEC14

INV FAULT 2 LEGEND COMES ON TOO


- DC BUS OFF 1 AND 2 CAUTION LIGHTS COME ON
- SHED LEGEND OF DC SVCE/UTLY BUS PUSHBUTTON
SWITCH COMES ON
NOTE: ON AIRCRAFT EQUIPPED WITH GROUND PROXIMITY WARNING SYSTEM (GPWS)  WHOOPWHOOP-PULL UP WARNING SOUNDS WHEN THE
SYSTEM IS ENERGIZED.
REF.FIG.244600-EAD-00110
3. OPEN DOOR 114BR GIVING ACCESS TO
DC EXTERNAL POWER RECEPTABLE
4. ON PANEL 5002VU PLUG IN THE GROUND
POWER UNIT PLUG TO RECEPTABLE
5. START THE GROUND POWER UNIT AND SUPPLY THE
AIRCRAFT BY MEANS OF IT
6. ON PANEL 5002VU CHECK THAT:
- DC CNCTD INDICATOR LIGHT COMES ON
- DC PWR NOT USED INDICATOR LIGHT COMES ON.
004

ENERGIZING OF DC AND AC CONSTANT FREQUENCY


__________________________________________
NETWORKS
________
REF. FIG. 244600-EAD-00100
REF. FIG. 244600-EAD-00110
REF. FIG. 244600-EAD-00100
1. ON PANEL 101VU
A. PLACE ELEC IND SELECTOR SWITCH IN EXT PWR
POSITION
B. VERIFY THAT THE VOLTAGE ON DC VOLTMETER
IS 28V
2. ON PANEL 29VU
A. MAKE CERTAIN THAT:
*** CONTINUED ***
AH

24-46-00
EAD 10000-003
2-400 PAGE
3
DEC 01/14

24-46-00

DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

EAD 10000-003
4

DEC14

- AVAIL LEGEND OF EXT PWR PUSHBUTTON


SWITCH COMES ON
- BTC PUSHBUTTON SWITCH IS IN RELEASED POSITION
- OVRD/UNDV PUSHBUTTON SWITCH IS IN
RELEASED POSITION
B. PRESS EXT PWR PUSHBUTTON SWITCH
- ON LEGEND COMES ON
C. SHED LEGEND OF DC SVCE/UTLY BUS PUSHBUTTON SWITCH GOES OFF
D. CHECK THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH COMES ON
- ALL BUS OFF AND INV FAULT LEGENDS OF
CAUTION LIGHTS GO OFF
- THE TWO ARROW LEGENDS OF BAT TIE CAUTION LIGHT GO OFF
- DC BUS1 AND 2 OFF CAUTION LIGHTS
GO OFF
REF. FIG. 244600-EAD-00110
3. ON PANEL 5002VU CHECK THAT:
DC PWR NOT USED INDICATOR LIGHT GOES
OFF
4. MAKE CERTAIN THAT ELECTRONICS RACK VENTILATION OPERATES CORRECTLY
005

DE-ENERGIZING OF DC AND AC CONSTANT FREQUENCY


_____________________________________________
NETWORKS
________
REF. FIG. 244600-EAD-00100
REF. FIG. 244600-EAD-00110
REF. FIG. 244600-EAD-00100
1. ON PANEL 29VU
A. RELEASE EXT PWR PUSHBUTTON SWITCH
- ON LEGEND GOES OFF
B. SHED LEGEND OF DC SVCE/UTLY BUS PUSHBUT*** CONTINUED ***
AH

24-46-00
EAD 10000-003
2-400 PAGE
4
DEC 01/14

DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

24-46-00

EAD 10000-003
5

DEC14

TON SWITCH COMES ON


C. MAKE CERTAIN THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH GOES OFF
- BUS OFF 1 AND 2 AND INV FAULT2 LEGENDS
OF CAUTION LIGHTS COME ON
- THE TWO ARROW LEGENDS OF BAT TIE CAUTION LIGHT COME ON
- DC BUS1 AND 2 OFF CAUTION LIGHTS
COME ON
REF. FIG. 244600-EAD-00110
2. ON PANEL 5002VU CHECK THAT:
DC PWR NOT USED INDICATOR LIGHT COMES ON
006

________
CLOSE
UP
REF. FIG. 244600-EAD-00100
REF. FIG. 244600-EAD-00110
1. CUT OFF THE EXTERNAL POWER TO AIRCRAFT AND
SHUT-DOWN THE GROUND POWER UNIT
REF. FIG. 244600-EAD-00110
2. ON PANEL 5002VU CHECK THAT:
- DC CNCTD INDICATOR LIGHT GOES OFF
- DC PWR NOT USED INDICATOR LIGHT GOES OFF
WARNING: IT IS FORBIDDEN TO UNPLUG THE GROUND
POWER UNIT PLUG WHEN THE CIRCUITIS
ENERGIZED AS THIS COULD CAUSE ARGING
WHICH WOULD BE DANGEROUS FOR PERSONNEL, OR DAMAGE TO EQUIPMENT
3. ON PANEL 5002VU UNPLUG THE GROUND POWER UNIT
PLUG FROM RECEPTACLE
4. CLOSE ACCESS DOOR 114BR
*** CONTINUED ***
AH

24-46-00
EAD 10000-003
2-400 PAGE
5
DEC 01/14

24-46-00

DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

EAD 10000-003
6

DEC14

REF.FIG. 244600-EAD-00100
5. ON PANEL 29VU
PLACE BAT SELECTOR SWITCH IN OFF POSITION
6. (ONLY IF THE A/C IS ON JACKS) ON PANEL 702VU
REPLACE NORM/FLT MODE SWITCH IN NORM
POSITION
*****

AH

E N D

O F

T E X T

*****

24-46-00
EAD 10000-003
2-400 PAGE
6
DEC 01/14

24-46-00
7

AH

CONTROLS AND INDICATING

EAD 10000-003
DEC14

24-46-00
EAD 10000-003

2-400

PAGE
7
DEC 01/14

24-46-00
8

AH

DC EXT PWR, ATTENDANT


AND ACCESS DOOR

EAD 10000-003
DEC14

24-46-00
EAD 10000-003

2-400

PAGE
8
DEC 01/14

24-46-00

DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

EAD 10000-004
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 114
210
: 114BR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELECTRIC

_________
MAN-HOURS
01

ELAPSED TIME

GSE

: 01 ELECTRICAL GND PWR UNIT

SEE ITEM SPEC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)

31-63-00-PRO-10000

PUBLICATION
___________
JIC

AH

24-46-00
EAD 10000-004
2-400 PAGE
1
DEC 01/14

24-46-00

DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

001

EAD 10000-004
2

DEC14

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

002

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

003

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

_______
WARNING
REF.FIG.244600-EAD-00100
1. BEFORE AIRCRAFT POWER SUPPLY MAKE CERTAIN
THAT SAFETY RULES MUST BE OBSERVED
2. ON PANEL 29VU MAKE CERTAIN THAT:
- BAT SELECTOR SWITCH IS IN OFF POSITION
- EXT PWR PUSHBUTTON SWITCH IS IN
RELEASED POSITION

004

___________
PREPARATION
REF.FIG.244600-EAD-00100
REF.FIG.244600-EAD-00110
*** CONTINUED ***
AH

24-46-00
EAD 10000-004
2-400 PAGE
2
DEC 01/14

24-46-00

DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

EAD 10000-004
3

DEC14

REF.FIG.244600-EAD-00100
(ONLY IF THE A/C IS ON JACKS)
1. ON PANEL 702VU
PLACE NORM/FLT MODE SWITCH IN FLT POSITION
2. ON PANEL 29VU
PLACE BAT SELECTOR SWITCH IN ON POSITION
AND VERIFY THAT:
- THE TWO ARROW LEGENDS OF BAT TIE CAUTION
LIGHT COME ON
- BUS OFF FOR AC BUS 1 AND 2 CAUTION
LIGHTS COME ON
- INV FAULT FOR INV 2 CAUTION LIGHT COMES
ON TOO
- DC BUS OFF FOR DC BUS 1 AND 2 CAUTION
LIGHTS COME ON
- SHED LEGEND OF DC SVCE/UTLY BUS PUSHBUTTON
SWITCH COMES ON
ON MFD UPPER WINDOW, IN ELEC SD PAGE:
- AMBER ARROWS ARE DISPLAYED ON EMER AND
MAIN BAT
- AMBER AC BUS 1 OFF AND AC BUS 2 OFF
SYMBOLS ARE DISPLAYED
- AMBER DC BUS 1 OFF AND DC BUS 2 OFF
SYMBOLS ARE DISPLAYED
- AMBER INV 2 FAULT SYMBOL IS DISPLAYED
- SHED LEGENDS ABOVE UTLY BUS 1 AND 2
SYMBOLS ARE DISPLAYED.
REF.FIG.244600-EAD-00110
3. OPEN DOOR 114BR GIVING ACCESS TO
DC EXTERNAL POWER RECEPTABLE
4. ON PANEL 5002VU PLUG IN THE GROUND
POWER UNIT PLUG TO RECEPTABLE
5. START THE GROUND POWER UNIT AND SUPPLY THE
AIRCRAFT BY MEANS OF IT
6. ON PANEL 5002VU CHECK THAT:
*** CONTINUED ***
AH

24-46-00
EAD 10000-004
2-400 PAGE
3
DEC 01/14

24-46-00

DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

EAD 10000-004
4

DEC14

- DC CNCTD INDICATOR LIGHT COMES ON


- DC PWR NOT USED INDICATOR LIGHTS
COMES ON.
005

ENERGIZING OF DC AND AC CONSTANT FREQUENCY


__________________________________________
NETWORKS
________
REF. FIG. 244600-EAD-00100
REF. FIG. 244600-EAD-00110
REF. FIG. 244600-EAD-00100
1. ON PANEL 101VU
A. PLACE ELEC IND SELECTOR SWITCH IN EXT PWR
POSITION
B. VERIFY THAT THE VOLTAGE ON DC VOLTMETER
IS 28V
2. ON PANEL 29VU
A. MAKE CERTAIN THAT:
- AVAIL LEGEND OF EXT PWR PUSHBUTTON
SWITCH COMES ON
- BTC PUSHBUTTON SWITCH IS IN RELEASED POSITION
- OVRD/UNDV PUSHBUTTON SWITCH IS IN
RELEASED POSITION
ON MFD UPPER WINDOW, IN ELEC SD PAGE:
- EXT PWR AVAIL SYMBOL IS DISPLAYED
- BTC SYMBOL IS DISPLAYED IN GREEN
WITHOUT FLOW BAR.
B. PRESS EXT PWR PUSHBUTTON SWITCH
- ON LEGEND COMES ON
ON MFD UPPER WINDOW, IN ELEC SD PAGE:
- EXT PWR AVAIL ON SYMBOL IS DISPLAYED
C. SHED LEGEND OF DC SVCE/UTLY BUS PUSHBUTTON SWITCH GOES OFF
CHECK THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH COMES ON
- ALL BUS OFF AND INV FAULT LEGENDS
OF CAUTION LIGHTS GO OFF
*** CONTINUED ***
AH

24-46-00
EAD 10000-004
2-400 PAGE
4
DEC 01/14

24-46-00

DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

EAD 10000-004
5

DEC14

- THE TWO ARROW LEGENDS OF BAT TIE


CAUTION LIGHTS GO OFF
- DC BUS OFF CAUTION LIGHTS GO OFF
GO OFF
ON MFD UPPER WINDOW, IN ELEC SD PAGE:
- SHED LEGENDS ABOVE UTLY BUS 1 AND 2
SYMBOLS ARE NO MORE DISPLAYED
- THE FLOW BAR LEGEND OF BTC SYMBOL
IS DISPLAYED
- GREEN AC BUS 1 AND AC BUS 2 ARE
DISPLAYED
- GREEN DC BUS 1 AND DC BUS 2 ARE
DISPLAYED
- GREEN INV 2 IS DISPLAYED
- AMBER ARROWS ARE NO MORE DISPLAYED ON
EMER AND MAIN BAT.
REF. FIG. 244600-EAD-00110
3. ON PANEL 5002VU CHECK THAT:
DC PWR NOT USED INDICATOR LIGHT GOES
OFF
4. MAKE CERTAIN THAT ELECTRONICS RACK VENTILATION OPERATES CORRECTLY
006

DE-ENERGIZING OF DC AND AC CONSTANT FREQUENCY


_____________________________________________
NETWORKS
________
REF. FIG. 244600-EAD-00100
REF. FIG. 244600-EAD-00110
REF. FIG. 244600-EAD-00100
1. ON PANEL 29VU
A. RELEASE EXT PWR PUSHBUTTON SWITCH
- ON LEGEND GOES OFF
ON MFD UPPER WINDOW, IN ELEC SD PAGE:
- EXT PWR AVAIL SYMBOL IS DISPLAYED
- BTC SYMBOL IS DISPLAYED IN GREEN
WITHOUT FLOW BAR.
*** CONTINUED ***
AH

24-46-00
EAD 10000-004
2-400 PAGE
5
DEC 01/14

DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

24-46-00

EAD 10000-004
6

DEC14

B. SHED LEGEND OF DC SVCE/UTLY BUS


PUSHBUTTON SWITCH COMES ON
MAKE CERTAIN THAT:
- THE FLOW BAR LEGEND OF BTC PUSHBUTTON
SWITCH GOES OFF
- BUS OFF FOR AC BUS 1 AND 2 AND INV
FAULT 2 FOR INV 2 CAUTION LIGHTS
COME ON
- THE TWO ARROW LEGENDS OF BAT TIE CAUTION LIGHT COME ON
- DC BUS OFF FOR DC BUS 1 AND 2 CAUTION
LIGHTS COMES ON
ON MFD UPPER WINDOW, IN ELEC SD PAGE:
- AMBER ARROWS ARE DISPLAYED ON EMER
AND MAIN BAT
- AMBER AC BUS 1 OFF AND AC BUS 2
OFF SYMBOLS ARE DISPLAYED
- AMBER DC BUS 1 OFF AND DC BUS 2
OFF SYMBOLS ARE DISPLAYED
- AMBER INV 2 FAULT SYMBOL IS DISPLAYED
- SHED LEGENDS ABOVE UTLY BUS 1
AND 2 SYMBOLS ARE DISPLAYED
REF. FIG. 244600-EAD-00110
2. ON PANEL 5002VU CHECK THAT:
DC PWR NOT USED INDICATOR LIGHT COMES ON
007

________
CLOSE
UP
REF. FIG. 244600-EAD-00100
REF. FIG. 244600-EAD-00110
1. CUT OFF THE EXTERNAL POWER TO AIRCRAFT AND
SHUT-DOWN THE GROUND POWER UNIT
REF. FIG. 244600-EAD-00110
2. ON PANEL 5002VU CHECK THAT:
- DC CNCTD INDICATOR LIGHT GOES OFF
- DC PWR NOT USED INDICATOR LIGHT GOES OFF
*** CONTINUED ***
AH

24-46-00
EAD 10000-004
2-400 PAGE
6
DEC 01/14

24-46-00

DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

EAD 10000-004
7

DEC14

WARNING: IT IS FORBIDDEN TO UNPLUG THE GROUND


POWER UNIT PLUG WHEN THE CIRCUITIS
ENERGIZED AS THIS COULD CAUSE ARGING
WHICH WOULD BE DANGEROUS FOR PERSONNEL, OR DAMAGE TO EQUIPMENT
3. ON PANEL 5002VU UNPLUG THE GROUND POWER UNIT
PLUG FROM RECEPTACLE
4. CLOSE ACCESS DOOR 114BR
REF.FIG. 244600-EAD-00100
5. ON PANEL 29VU
PLACE BAT SELECTOR SWITCH IN OFF POSITION
6. (ONLY IF THE A/C IS ON JACKS) ON PANEL 702VU
REPLACE NORM/FLT MODE SWITCH IN NORM
POSITION
*****

AH

E N D

O F

T E X T

*****

24-46-00
EAD 10000-004
2-400 PAGE
7
DEC 01/14

24-46-00
8

AH

CONTROLS AND INDICATING

EAD 10000-004
DEC14

24-46-00
EAD 10000-004

2-400

PAGE
8
DEC 01/14

24-46-00
9

AH

DC EXT PWR, ATTENDANT


AND ACCESS DOOR

EAD 10000-004
DEC14

24-46-00
EAD 10000-004

2-400

PAGE
9
DEC 01/14

24-46-00

SHEDDING PROCEDURE TO
REDUCE ON GROUND THE DC
LOAD DEMAND

PRO 10000-001
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

AH

24-46-00
PRO 10000-001
2-400 PAGE
1
DEC 01/14

24-46-00

SHEDDING PROCEDURE TO
REDUCE ON GROUND THE DC
LOAD DEMAND

001

PRO 10000-001
2

DEC14

___________
PREPARATION
1. BEFORE THE DC EXT PWR AIRCRAFT ENERGIZATION,
CHECK THE DC LOAD CAPABILITY OF GPU UTILIZED
2. IF FOR ANY REASON, IT IS NOT POSSIBLE TO
KNOW THE DC LOAD CAPABILITY OF GPU UTILIZED,
PERFORM COMPLETELY THE FOLLOWING SHEDDING
PROCEDURE.
IN THIS CASE THE TOTAL ATR72 DC LOAD REDUCTION IS : 116 AMPS.
NOTE : THE ATR72 DC LOAD DEMAND IS :
400 AMPS.

002

SHEDDING PROCEDURE OF RECIRCULATION


___________________________________
FANS 1 AND 2
____________
REF. FIG. 212200-OPT-00100
RECIRCULATION FAN 1 AND 2
LOAD
:
28,5 AMPS
QTY
:
2
TOTAL LOAD REDUCTION :
57 AMPS
ON PANEL 22VU COMPT TEMP SECTION, SELECT
OFF THE RECIRC FAN 1 AND RECIRC FAN 2
PUSHBUTTON SWITCHES.
- OFF WHITE LIGHTS ON THE SAME PUSHBUTTON
SWITCHES COME ON.

003

________________________________________
SHEDDING
PROCEDURE OF FUEL PUMPS 1 AND 2
REF. FIG. 282100-OPT-00120
FUEL PUMPS 1 AND 2
LOAD
: 9.5 AMPS
QUANTITY
: 2
TOTAL LOAD ERDUCTION: 19 AMPS
ON PANEL 25VU FUEL SECTION, SELECT OFF BOTH
PUMP PUSHBUTTON SWITCHES:
*** CONTINUED ***
AH

24-46-00
PRO 10000-001
2-400 PAGE
2
DEC 01/14

24-46-00

SHEDDING PROCEDURE TO
REDUCE ON GROUND THE DC
LOAD DEMAND

PRO 10000-001
3

DEC14

- OFF WHITE LIGHTS, ON BOTH SWITCHES, COME


ON.
004

SHEDDING PROCEDURE OF CEILING LIGHTING IN


_________________________________________
PASSENGER COMPARTMENT.
______________________
REF. FIG.: 332000-OPT-00100
CEILING LIGHTING IN PASSENGER COMPARTMENT :
LOAD :
: 1,65 AMPS
QUANTITY :
: 24
TOTAL LOAD REDUCTION : 40 AMPS
ON CABIN ATTENDANT PANEL LIGHT SECTION,
SELECT OFF THE UPR PASS SWITCH :
- OFF LIGHT GOES OFF.
*****

AH

E N D

O F

T E X T

*****

24-46-00
PRO 10000-001
2-400 PAGE
3
DEC 01/14

24-46-00
4

AH

CABIN AND FLIGHT


COMPARTMENT OPERATIONAL
TEST

PRO 10000-001
DEC14

24-46-00
PRO 10000-001

2-400

PAGE
4
DEC 01/14

24-46-00
5

AH

FUEL DISTRIBUTION
OPERATIONAL TEST

PRO 10000-001
DEC14

24-46-00
PRO 10000-001

2-400

PAGE
5
DEC 01/14

24-46-00
6

AH

OPERATIONAL TEST
OF PASSENGER COMPARTMENT
LIGHTING

PRO 10000-001
DEC14

24-46-00
PRO 10000-001

2-400

PAGE
6
DEC 01/14

24-46-00

SHEDDING PROCEDURE TO
REDUCE ON GROUND THE DC
LOAD DEMAND

PRO 10000-002
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

AH

24-46-00
PRO 10000-002
2-400 PAGE
1
DEC 01/14

24-46-00

SHEDDING PROCEDURE TO
REDUCE ON GROUND THE DC
LOAD DEMAND

001

PRO 10000-002
2

DEC14

___________
PREPARATION
1. BEFORE THE DC EXT PWR AIRCRAFT ENERGIZATION,
CHECK THE DC LOAD CAPABILITY OF GPU UTILIZED
2. IF FOR ANY REASON, IT IS NOT POSSIBLE TO
KNOW THE DC LOAD CAPABILITY OF GPU UTILIZED,
PERFORM COMPLETELY THE FOLLOWING SHEDDING
PROCEDURE.
IN THIS CASE THE TOTAL ATR72 DC LOAD REDUCTION IS : 116 AMPS.
NOTE : THE ATR72 DC LOAD DEMAND IS :
400 AMPS.

002

SHEDDING PROCEDURE OF RECIRCULATION


___________________________________
FANS 1 AND 2
____________
REF. FIG. 212200-OPT-00100
RECIRCULATION FAN 1 AND 2
LOAD
:
28,5 AMPS
QTY
:
2
TOTAL LOAD REDUCTION :
57 AMPS
A. ON PANEL 22VU COMPT TEMP SECTION, SELECT
OFF THE RECIRC FAN 1 AND RECIRC FAN 2
PUSHBUTTON SWITCHES.
- OFF WHITE LIGHTS ON THE SAME PUSHBUTTON
SWITCHES COME ON.
B. ON MFD UPPER WINDOW, IN CABIN SD PAGE,
WHITE RECIRC SYMBOL WITH WHITE CIRCLES
ARE DISPLAYED.

003

________________________________________
SHEDDING
PROCEDURE OF FUEL PUMPS 1 AND 2
REF. FIG. 282100-OPT-00120
FUEL PUMPS 1 AND 2
LOAD
: 9.5 AMPS
QUANTITY
: 2
TOTAL LOAD ERDUCTION: 19 AMPS
*** CONTINUED ***
AH

24-46-00
PRO 10000-002
2-400 PAGE
2
DEC 01/14

24-46-00

SHEDDING PROCEDURE TO
REDUCE ON GROUND THE DC
LOAD DEMAND

PRO 10000-002
3

DEC14

ON PANEL 25VU FUEL SECTION, SELECT OFF BOTH


PUMP PUSHBUTTON SWITCHES:
- OFF WHITE LIGHTS, ON BOTH SWITCHES, COME
ON.
004

SHEDDING PROCEDURE OF CEILING LIGHTING IN


_________________________________________
PASSENGER COMPARTMENT
_____________________
REF. FIG. 332000-OPT-00100
ON FLIGHT ATTENDANT PANEL 10MW:
- SELECT CABIN CEILING
- TURN OFF THE LIGHTS BY PRESSING - UNTIL
THE INDICATORS LIGHTS ARE TURNED OFF.
*****

AH

E N D

O F

T E X T

*****

24-46-00
PRO 10000-002
2-400 PAGE
3
DEC 01/14

24-46-00
4

AH

CABIN AND FLIGHT


COMPARTMENT OPERATIONAL
TEST

PRO 10000-002
DEC14

24-46-00
PRO 10000-002

2-400

PAGE
4
DEC 01/14

24-46-00
5

AH

FUEL DISTRIBUTION
OPERATIONAL TEST

PRO 10000-002
DEC14

24-46-00
PRO 10000-002

2-400

PAGE
5
DEC 01/14

24-46-00
6

AH

OPERATIONAL TEST
OF PASSENGER COMPARTMENT
LIGHTING

PRO 10000-002
DEC14

24-46-00
PRO 10000-002

2-400

PAGE
6
DEC 01/14

24-46-11

REMOVAL AND INSTALLATION


OF DC GROUND POWER
RECEPTACLE 1PG

RAI 10000-001
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 114
: 114BR
212HF

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

SPARE

: 01 RECEPTACLE

244610-50

EXPENDABLE

: 02 NUT

244610-50

BULK MATERIAL : SEALANT (09-001F)


OR
SEALANT

_________
MAN-HOURS

09-001
09-002

PUBLICATION
___________
JIC
JIC

: REMOVAL AND INSTALLATION


OF FLIGHT COMPARTMENT
FLOOR COVERING
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

25-13-16-RAI-10000
24-46-00-EAD-10000

24-46-11
RAI 10000-001
2-400 PAGE
1
DEC 01/14

24-46-11

REMOVAL AND INSTALLATION


OF DC GROUND POWER
RECEPTACLE 1PG

001

RAI 10000-001
2

DEC14

____________________________________________
REMOVAL
OF FLIGHT COMPARTMENT FLOOR COVERING
SEE JOB INSTRUCTION CARD
251316-RAI-10000

002

___________
PREPARATION
1. REMOVE ACCESS PANEL 212HF.
2. OPEN DOOR 114BR.

003

_____________________________________
REMOVAL
OF DC GROUND POWER RECEPTACLE
REF. FIG. 244611-RAI-00100
1. REMOVE THE SCREWS (1) AND WASHERS (2).
REMOVE COVER (3).
2. NOTE THE POSITION OF WIRES AND DISCONNECT
THEM.
3. REMOVE AND DISCARD NUTS (7) AND REMOVE
WASHERS (6).
4. REMOVE SCREWS (4) AND RECEPTACLE (5).

004

__________________________________________
INSTALLATION
OF DC GROUND POWER RECEPTACLE
REF. FIG. 244611-RAI-00100
1. APPLY PRODUCT 09-001F (REF. AMM 20-31-00)
ON THE BASE OF THE RECEPTACLE (5).
2. INSTALL THE RECEPTACLE (5) AND THE TWO
SCREWS (4).
3. FROM INTERNAL ACCESS, INSTALL WASHERS (6)
AND NUTS (7) AND TIGHTEN NUTS.
4. RECONNECT WIRES FOLLOWING THE POSITION NOTED
DURING REMOVAL
(TIGHTENNING TORQUE VALUE:
- FOR CONTACT WITH A DIAMETER OF 11.07 MM /
0.4358 IN : TIGHTEN AT 0.86 MDAN TO 0.95
MDAN / 76.10 LBF.IN TO 84.07 LBF.IN.
- FOR CONTACT WITH A DIAMETER OF 7.89 MM /
0.3106 IN : TIGHTEN AT 0.21 MDAN TO 0.24
MDAN / 18.58 LBF.IN TO 21.23 LBF.IN.)
5. POSITION THE COVER (3) AND INSTALL WASHERS
(2) AND THE SCREWS (1).
*** CONTINUED ***
AH

24-46-11
RAI 10000-001
2-400 PAGE
2
DEC 01/14

24-46-11

REMOVAL AND INSTALLATION


OF DC GROUND POWER
RECEPTACLE 1PG

005

RAI 10000-001
3

DEC14

________
CLOSE-UP
1. INSTALL ACCESS PANEL 212HF.
2. CLOSE DOOR 114BR.

006

INSTALLATION OF FLIGHT COMPARTMENT FLOOR


________________________________________
COVERING
________
SEE JOB INSTRUCTION CARD
251316-RAI-10000

007

______________________________________________
OPERATIONAL
TEST OF DC GROUND POWER RECEPTACLE
DO AN ENERGIZATION AND DE-ENERGIZATION OF DC
AND AC CONSTANT FREQUENCY EXTERNAL POWER SUPPLY
ACCORDING TO THE FOLLOWING CARDS.

008

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

009

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-46-11
RAI 10000-001
2-400 PAGE
3
DEC 01/14

24-46-11
4

AH

REMOVAL AND INSTALLATION


OF DC GROUND POWER
RECEPTACLE

RAI 10000-001
DEC14

24-46-11
RAI 10000-001

2-400

PAGE
4
DEC 01/14

24-46-83

DC BUS POWER CONTROL


UNIT OPERATIONAL TEST

OPT 10000-001
1

MAR13

ZONING DATA
___________
ZONE
ACCESS

: 214
: 214BZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELECTRONIC
ELAPSED TIME

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: POWER SUPPLY FROM


BATTERIES

AH

24-31-00-EAD-10000

24-46-83
OPT 10000-001
2-400 PAGE
1
MAR 01/13

24-46-83

DC BUS POWER CONTROL


UNIT OPERATIONAL TEST

001

OPT 10000-001
2

MAR13

_________________________________
ENERGIZING
OF SYSTEM FROM BATTERY
SEE JOB INSTRUCTION CARD
243100-EAD-10000

002

___________
PREPARATION
REF.FIG. 240000-RAI-00103
1. ON R ELECTRONICS RACK 90VU (B)
OPEN ACCESS DOOR 214BZ

003

__________________________________________
DC
BUS POWER CONTROL UNIT OPERATIONAL TEST
REF.FIG.244613-OPT-00100
1. ON R ELECTRONICS RACK 90VU SHELF 5
ON DC BPCU FRONT PANEL (B) PRESS AND HOLD
THE CL SWITCH.VERIFY THAT THE CC INDICATOR
LIGHT COMES ON.
IF DC BPCU ARE IN SATISFACTORY CONDITION,
THE INDICATOR LIGHT WILL BE ON FOR
15 SEC +/- 1SEC THEN IT GOES OFF.
IF ONE CIRCUIT OF THE BPCU IS DEFECTIVE,
THE INDICATOR LIGHT WILL BE ON FOR 15 SEC,
THEN IT GOES OFF FOR 100 MILLISECONDS,
SUBSEQUENTLY AGAIN IT COMES ON AND IT
REMAINS ON AS LONG THE PUSH-BUTTON IS KEPT
PRESSED.

004

________
CLOSE
UP
REF.FIG.240000-RAI-00103
1. ON R ELECTRONICS RACK 90VU (B)
CLOSE ACCESS DOOR 214BZ

005

____________________________________
DE-ENERGIZING
OF SYSTEM FROM BATTERY
SEE JOB INSTRUCTION CARD
243100-EAD-10000
*****
AH

E N D

O F

T E X T

*****

24-46-83
OPT 10000-001
2-400 PAGE
2
MAR 01/13

24-46-83
3

AH

ACCESS DOOR AND FRONT PA


NEL

OPT 10000-001
MAR13

24-46-83
OPT 10000-001

2-400

PAGE
3
MAR 01/13

24-46-83
4

AH

ACCESS DOORS, C/B PANELS


& SHELVES (90VU - 120VU)

OPT 10000-001
MAR13

24-46-83
OPT 10000-001

2-400

PAGE
4
MAR 01/13

24-46-83

DC BUS POWER CONTROL


UNIT REMOVAL AND
INSTALLATION

RAI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 120
214
: 122VU 124VU 125VU 127VU 128VU
214BZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: DC BUS POWER CONTROL


UNIT OPERATIONAL TEST

AH

24-46-83-OPT-10000

24-46-83
RAI 10000-001
2-400 PAGE
1
APR 01/05

24-46-83

DC BUS POWER CONTROL


UNIT REMOVAL AND
INSTALLATION

001

RAI 10000-001
2

APR05

___________
PREPARATION
REF. FIG. 240000-RAI-00103
1. OPEN, SAFETY CLIP AND TAG THE FOLLOWING CIRCUIT BREAKERS:
- ON PANEL 122VU (A)
8PG MAIN ELEC PWR-DC/DC EXT PWR INTLK
15PG MAIN ELEC PWR-DC/BPCU DC
35PU(38PU) MAIN ELEC PWR-DC/GCU DC GEN 1
(GCU DC GEN 2)
- ON PANEL 125VU (A)
4PG EXT PWR/BPCU CTL
13PU DC GEN1/CTL/EXCN
51PU DC GEN1/CTL/POR
- ON PANEL 127VU (A)
53PU DC GEN 1/CTL/BUS V SNSG
- ON PANEL 128VU (A)
14PU DC GEN 2/CTL/EXCN
52PU DC GEN 2/CTL/POR
2. ON R ELECTRONICS RACK 90VU (B)
OPEN ACCESS DOOR 214BZ

002

REMOVAL OF EQUIPMENT FROM L OR R ELECTRONICS


____________________________________________
RACKS 80VU OR 90VU
__________________
REF. FIG. 310000-RAI-00105
NOTE : THE SHAPE AND QUANTITY OF AFT BACKSHELLS
AS WELL AS THE QUANTITY OF FASTENERS MAY
BE DIFFERENT ACCORDING THE EQUIPMENT.
NEVERTHLESS, THE REMOVAL AND INSTALLATION PROCEDURE IS IDENTICAL.
1. REMOVE CORRESPONDING ACCESS PANEL.
2. UNSCREW KNURLED KNOBS (3) ATTACHING
EQUIPMENT (1) TO RACK (4).
3. PULL EQUIPMENT (1) AND REMOVE FROM ITS
*** CONTINUED ***
AH

24-46-83
RAI 10000-001
2-400 PAGE
2
APR 01/05

24-46-83

DC BUS POWER CONTROL


UNIT REMOVAL AND
INSTALLATION

RAI 10000-001
3

APR05

RACK (4).
4. INSTALL PROTECTIVE PLUGS ON EQUIPMENT SIDE
ELECTRICAL CONNECTORS (5).
003

INSTALLATION OF EQUIPMENT IN L OR R ELECTRONICS


_______________________________________________
RACKS 80VU OR 90VU
__________________
REF. FIG. 310000-RAI-00105
1. CLEAN AND INSPECT EQUIPMENT (1) AND RACK
(4) INTERFACE AREA.
2. REMOVE PROTECTIVE CAPS INSTALLED ON
EQUIPMENT SIDE ELECTRICAL CONNECTORS (5).
3. INSTALL EQUIPMENT (1) IN ITS RACK (4).
4. BLOCK EQUIPMENT BY MEANS OF ITS KNURLED
ATTACHMENT KNOBS (2) AND (3).

004

________
CLOSE
UP
REF. FIG. 240000-RAI-00103
1. ON R ELECTRONICS RACK 90VU(B)
CLOSE ACCESS DOOR 214BZ
2. REMOVE SAFETY CLIPS AND TAGS AND CLOSE THE
FOLLOWING CIRCUIT BREAKERS:
- ON PANEL 122VU (A)
8PG
15PG
35PU(38PU)
- ON PANEL 125VU (A)
4PG
13PU
51PU
- ON PANEL 127VU (A)
53PU
- ON PANEL 128VU (A)
*** CONTINUED ***
AH

24-46-83
RAI 10000-001
2-400 PAGE
3
APR 01/05

24-46-83

DC BUS POWER CONTROL


UNIT REMOVAL AND
INSTALLATION

RAI 10000-001
4

APR05

14PU
52PU
005

__________________________________________
DC
BUS POWER CONTROL UNIT OPERATIONAL TEST
SEE JOB INSTRUCTION CARD
244683-OPT-10000
*****

AH

E N D

O F

T E X T

*****

24-46-83
RAI 10000-001
2-400 PAGE
4
APR 01/05

24-46-83
5

AH

ACCESS DOORS, C/B PANELS


& SHELVES (90VU - 120VU)

RAI 10000-001
APR05

24-46-83
RAI 10000-001

2-400

PAGE
5
APR 01/05

24-46-83
6

AH

L AND R ELECTRONICS
RACKS 80VU AND 90VU
EQUIPMENT

RAI 10000-001
APR05

24-46-83
RAI 10000-001

2-400

PAGE
6
APR 01/05

24-46-84

DC EXT PWR CONTACTOR


REMOVAL AND INSTALLATION

RAI 10000-001
1

MAR15

ZONING DATA
___________
ZONE
ACCESS

: 212
220
: 212TZ 212VZ 214BZ 214PZ 222CZ 222QZ 222RZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

SPARE

: 01
01
01
01
01

AH

___
MEN

_________
MAN-HOURS
01

CONTACTOR:11PG
TERMINAL STRIP:1PP
TERMINAL STRIP:2PP
TERMINAL STRIP:5PP
TERMINAL STRIP:6PP

24-46-80-XX-XXX
24-69-80-XX-XXX
24-69-80-XX-XXX
24-69-80-XX-XXX
24-69-80-XX-XXX

24-46-84
RAI 10000-001
2-400 PAGE
1
MAR 01/15

24-46-84

DC EXT PWR CONTACTOR


REMOVAL AND INSTALLATION

001

RAI 10000-001
2

MAR15

___________
PREPARATION
REF. FIG. 240000-RAI-00100 (FIG.1)
REF. FIG. 240000-RAI-00103 (FIG.2)
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO THE DC AND AC EXTERNAL POWER RECEPTACLES (ON PANELS 5002VU AND 5000VU
-FIG.1-F AND D) AND THE ACCESS DOORS 114BR
AND 114CR (FIG.1-E AND C) ARE CLOSED
2. ON PANEL 29VU (FIG.1-A) MAKE CERTAIN THAT:
BAT SELECTOR SWITCH 7PA IS IN OFF POSITION
3. DISPLAY A WARNING NOTICE ON PANELS 29VU AND
26VU (FIG.1-B) PROHIBITING POWER SUPPLY TO
SYSTEM
4. ON DC/AC POWER CENTER 120VU OR ON ELECTRONICS RACK 90VU (FIG.2 A AND B AND THE CORRESPONDING FIGURE OF EACH RAI)
120VU: REMOVE ACCESS PANEL 212TZ OR 212VZ
(123VU) OR CIRCUIT BREAKER PANEL 121V
U OR 122VU OR 124VU OR 125VU OR 126VU
OR 127VU OR 128VU OR 129VU OR 130VU
90VU - SIDE SHELF: REMOVE ACCESS PANEL 222RZ
(SHELF 91VU) OR 222QZ (SHELF 91VU OR
92VU OR 93VU) OR 222PZ (SHELF 94VU OR
95VU)
- FRONT SHELF: REMOVE ACCESS PANEL 214
CZ(SHELF 91VU OR 92VU) OR 214BZ(SHELF
93VU OR 94VU OR 95VU)

002

______________________________________
REMOVAL
OF DC EXTERNAL POWER CONTACTOR
REF.FIG.244614-RAI-00100
1. REMOVE NUTS (2) AND WASHERS (3) TO DISCONNECT THE CONTACTOR (1) FROM TERMINAL STRIPS
5PP(2PP) (6) AND 1PP(6PP) (4)
*** CONTINUED ***
AH

24-46-84
RAI 10000-001
2-400 PAGE
2
MAR 01/15

24-46-84

DC EXT PWR CONTACTOR


REMOVAL AND INSTALLATION

RAI 10000-001
3

MAR15

2. REMOVE CAPTIVE SCREWS (7) TO DISCONNECT THE


ELECTRICAL CONNECTOR (5)
3. REMOVE CONTACTOR WITH CARE TO NOT DAMAGE
THE ELECTRICAL CONNECTOR
003

___________________________________________
INSTALLATION
OF DC EXTERNAL POWER CONTACTOR
REF.FIG.244614-RAI-00100
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/
OR COMPONENT ADJACENT AREA.
2. INSTALL CONTACTOR (1) WITH ITS ELECTRICAL
CONNECTOR (5)
3. TIGHTEN CAPTIVE SCREWS (5)
4. CONNECT CONTACTOR TO TERMINAL STRIPS 5PP
(2PP) (6) AND 1PP(6PP) (4)
5. INSTALL WASHERS (3) AND NUTS (2). TIGHTEN
NUTS (TIGHTENING TORQUE VALUE: 1,65 MDAN /
146 LBF X IN)
NOTE: MARK NUTS (2) WITH RED VARNISH

004

________
CLOSE
UP
REF. FIG. 240000-RAI-00100 (FIG.1)
REF. FIG. 240000-RAI-00103 (FIG.2)
1. ON DC/AC POWER CENTER 12OVU OR ON ELECTRONICS RACK 90VU (FIG.2 A OR B AND THE CORRESPONDING FIGURE OF EACH RAI)
120VU: CLOSE ACCESS PANEL 212TZ OR 212VZ OR
CIRCUIT BREAKER PANEL 121VU OR 122VU
OR 124VU OR 125VU OR 127VU OR 128VU
OR 129VU OR 130VU
90VU - SIDE SHELF: CLOSE ACCESS PANEL 222RZ
OR 222QZ OR 222PZ
*** CONTINUED ***
AH

24-46-84
RAI 10000-001
2-400 PAGE
3
MAR 01/15

24-46-84

DC EXT PWR CONTACTOR


REMOVAL AND INSTALLATION

RAI 10000-001
4

MAR15

- FRONT SHELF: CLOSE ACCESS PANEL 214CZ


OR 214BZ
2. REMOVE THE WARNING NOTICE FROM PANELS 29VU
AND 26VU (FIG.1-A AND B)
005

________________
OPERATIONAL
TEST
THIS TEXT IS NOT APPLICABLE
*****

AH

E N D

O F

T E X T

*****

24-46-84
RAI 10000-001
2-400 PAGE
4
MAR 01/15

24-46-84
5

AH

CONTROLS AND INDICATING

RAI 10000-001
MAR15

24-46-84
RAI 10000-001

2-400

PAGE
5
MAR 01/15

24-46-84
6

AH

ACCESS DOORS, C/B PANELS


& SHELVES (90VU - 120VU)

RAI 10000-001
MAR15

24-46-84
RAI 10000-001

2-400

PAGE
6
MAR 01/15

24-46-84
7

AH

RAI OF DC EXTERNAL POWER

RAI 10000-001
MAR15

24-46-84
RAI 10000-001

2-400

PAGE
7
MAR 01/15

24-47-00

DC SERVICE AND GROUND


HANDLING BUSES EXTERNAL
POWER SUPPLY

EAD 10000-003
1

MAR14

ZONING DATA
___________
ZONE
ACCESS

: 114
210
221
: 114BR
221AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC
MECHANIC

___
MEN

_________
MAN-HOURS
01
01

ELAPSED TIME

GSE

: 01 ELECTRICAL GND PWR UNIT

AH

SEE ITEM SPEC

24-47-00
EAD 10000-003
2-400 PAGE
1
MAR 01/14

24-47-00

DC SERVICE AND GROUND


HANDLING BUSES EXTERNAL
POWER SUPPLY

001

EAD 10000-003
2

MAR14

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

002

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

_______
WARNING
REF.FIG.244600-EAD-00100
1. BEFORE AIRCRAFT POWER SUPPLY MAKE CERTAIN
THAT SAFETY RULES MUST BE OBSERVED
2. ON PANEL 29VU MAKE CERTAIN THAT:
- BAT SELECTOR SWITCH IS IN OFF POSITION
- EXT PWR PUSHBUTTON SWITCH IS IN
RELEASED POSITION

003

___________
PREPARATION
REF.FIG.244600-EAD-00100
REF.FIG.244600-EAD-00110
REF.FIG.244700-EAD-00100
REF.FIG.244600-EAD-00100
1. (ONLY IF THE A/C IS ON JACKS) ON PANEL 702VU
PLACE NORM/FLT MODE SWITCH IN FLT POSITION
REF.FIG.244700-EAD-00100
2. OPEN DOOR 221AL GIVING ACCESS TO
PANEL 5001VU
REF.FIG.244600-EAD-00110
*** CONTINUED ***
AH

24-47-00
EAD 10000-003
2-400 PAGE
2
MAR 01/14

24-47-00

DC SERVICE AND GROUND


HANDLING BUSES EXTERNAL
POWER SUPPLY

EAD 10000-003
3

MAR14

3. ON PANEL 5001VU CHECK THAT:


GND HDL ON BAT WARNING LIGHT COMES ON
4. OPEN DOOR 114BR GIVING ACCESS TO
DC EXTERNAL POWER RECEPTACLE
5. ON PANEL 5002VU PLUG IN THE GROUND
POWER UNIT PLUG TO RECEPTACLE
6. START THE GROUND POWER UNIT AND SUPPLY THE
AIRCRAFT BY MEANS OF IT
7. ON PANEL 5002VU CHECK THAT:
- DC CNCTD INDICATOR LIGHT IS ON
- DC PWR NOT USED INDICATOR LIGHT IS ON
004

ENERGIZING OF DC SERVICE AND GROUND HANDLING


____________________________________________
BUSES
_____
REF.FIG.244600-EAD-00100
REF.FIG.244600-EAD-00110
1. ON PANEL 101VU:
A. PLACE SELECTOR SWITCH ELEC IND IN
EXT PWR POSITION.
B. VERIFY THAT THE VOLTAGE ON DC VOLTMETER
IS 28V.
2. ON PANEL 29VU MAKE CERTAIN THAT:
AVAIL LEGEND OF P/BSW EXT PWR IS ON.
3. ON (FLIGHT) ATTENDANT PANEL:
A. MAKE CERTAIN THAT SHED LEGEND OF
P/BSW GND SVCE BUS DC IS ON.
B. PRESS P/BSW GND SVCE BUS DC:
- ON LEGEND COMES ON.
- SHED LEGEND GOES OFF.
4. ON PANEL 5002VU CHECK THAT:
INDICATOR LIGHT DC PWR NOT USED GOES
*** CONTINUED ***
AH

24-47-00
EAD 10000-003
2-400 PAGE
3
MAR 01/14

24-47-00

DC SERVICE AND GROUND


HANDLING BUSES EXTERNAL
POWER SUPPLY

EAD 10000-003
4

MAR14

OFF.
005

DE-ENERGIZING OF DC SERVICE AND GROUND HANDLING


_______________________________________________
BUSES
_____
REF.FIG.244600-EAD-00110
1. ON (FLIGHT) ATTENDANT PANEL:
PRESS P/BSW DC GND SVCE BUS AND CHECK THAT
- ON LEGEND GOES OFF.
- SHED LEGEND COMES ON.
2. ON PANEL 5002VU CHECK THAT:
INDICATOR LIGHT DC PWR NOT USED COMES
ON.

006

________
CLOSE
UP
REF.FIG.244600-EAD-00100
REF.FIG.244600-EAD-00110
REF.FIG.244700-EAD-00100
1. CUT OFF THE EXTERNAL POWER TO AIRCRAFT AND
SHUT-DOWN THE GROUND POWER UNIT
REF.FIG.244600-EAD-00110
2. ON PANEL 5002VU CHECK THAT:
- DC CNCTD INDICATOR LIGHT GOES OFF
- DC PWR NOT USED INDICATOR LIGHT GOES
OFF
WARNING: IT IS FORBIDDEN TO UNPLUG THE GROUND
POWER UNIT PLUG WHEN THE CIRCUITIS
ENERGIZED AS THIS COULD CAUSE ARCING
WHICH WOULD BE DANGEROUS FOR PERSONNEL OR DANNAGE TO EQUIPMENT
3. ON PANEL 5002VU UNPLUG THE GROUND POWER UNIT
PLUG FROM THE DC EXTERNAL POWER RECEPTACLE
*** CONTINUED ***
AH

24-47-00
EAD 10000-003
2-400 PAGE
4
MAR 01/14

24-47-00

DC SERVICE AND GROUND


HANDLING BUSES EXTERNAL
POWER SUPPLY

EAD 10000-003
5

MAR14

4. CLOSE ACCESS DOOR 114BR


REF.FIG.244700-EAD-00100
5. CLOSE ACCESS DOOR 221AL
REF.FIG.244600-EAD-00100
6. (ONLY IF THE A/C IS ON JACKS) ON PANEL 702VU
REPLACE NORM/FLT MODE SWITCH IN NORM
POSITION
*****

AH

E N D

O F

T E X T

*****

24-47-00
EAD 10000-003
2-400 PAGE
5
MAR 01/14

24-47-00
6

AH

CARGO COMPT DOOR, ATTENDANT AND C/B PANELS

EAD 10000-003
MAR14

24-47-00
EAD 10000-003

2-400

PAGE
6
MAR 01/14

24-47-00
7

AH

CONTROLS AND INDICATING

EAD 10000-003
MAR14

24-47-00
EAD 10000-003

2-400

PAGE
7
MAR 01/14

24-47-00
8

AH

DC EXT PWR, ATTENDANT


AND ACCESS DOOR

EAD 10000-003
MAR14

24-47-00
EAD 10000-003

2-400

PAGE
8
MAR 01/14

24-50-00

OPERATIONAL TEST OF AC,


ACW AND DC NORMAL
DISTRIBUTION

OPT 10000-001
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC

: DC AND AC EXTERNAL POWER


SUPPLY

AH

24-40-00-EAD-10000

24-50-00
OPT 10000-001
2-400 PAGE
1
DEC 01/14

24-50-00

OPERATIONAL TEST OF AC,


ACW AND DC NORMAL
DISTRIBUTION

001

OPT 10000-001
2

DEC14

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

002

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

003

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

OPERATIONAL TEST OF DIRECT CURRENT AND


______________________________________
ALTERNATIVE CURRENT (CONSTANT AND WILD
______________________________________
FREQUENCY) NORMAL LOAD DISTRIBUTION
___________________________________
REF. FIG. 245000-OPT-00100
1. NOTE: OPERATIONAL TEST OF DIRECT CURRENT
AND ALTERNATIVE CURRENT (CONSTANT AND
WILD FREQUENCY) NORMAL LOAD DISTRIBUTION IS IDENTICAL THROUGHOUT PROCEDURE
BUT EACH CIRCUIT BREAKER C/B CORRESPONDS TO A DIFFERENT ANNUNCIATOR
LIGHT AS SHOWN BELOW:
C/B
3XN
4XN
5XB
6XB
7PN
8PN

ANNUNCIATOR LIGHT
MAIN ELEC PWR/AC BUS
MAIN ELEC PWR/AC BUS
AC WILD ELEC PWR/ACW
AC WILD ELEC PWR/ACW
MAIN ELEC PWR/DC BUS
MAIN ELEC PWR/DC BUS

1/BUS OFF/INV
2/BUS OFF/INV
BUS 1/ACW BUS
BUS 2/ACW BUS
1/DC BUS OFF
2/DC BUS OFF

FAULT
FAULT
OFF
OFF

ON MAIN ELEC PWR PANEL (29VU) AND AC WILD


ELEC PWR PANEL (26VU),BUS OFF FOR AC BUS 1
*** CONTINUED ***
AH

24-50-00
OPT 10000-001
2-400 PAGE
2
DEC 01/14

24-50-00

OPERATIONAL TEST OF AC,


ACW AND DC NORMAL
DISTRIBUTION

OPT 10000-001
3

DEC14

AND 2, ACW BUS OFF FOR ACW BUS 1 AND 2 AND


DC BUS OFF FOR DC BUS 1 AND 2 CAUTION
LIGHTS ARE OFF.
2. TYPICAL TEST FOR A DISTRIBUTION CIRCUIT
A. OPEN CIRCUIT BREAKER C/B:
CHECK THAT:
- ANNUNTIATOR LIGHT COMES ON AMBER.
- ON CAP, ELEC CAUTION LIGHT AND
MASTER CAUTION LIGHTS COME ON AMBER.
- SINGLE CHIME SOUNDS AT LOUDSPEAKERS.
NOTE: FOR OPERATIONAL TEST OF ALTERNATIVE
CURRENT (WILD FREQUENCY), IF CONDITION
LEVERS ARE BELOW FTR POSITION:
- MASTER CAUTION LIGHTS ARE OFF.
- SINGLE CHIME DOESN}T SOUND.
B. CLOSE CIRCUIT BREAKER C/B.
- CHECK THAT ALL ANNUNCIATOR LIGHTS,
ELEC CAUTION LIGHT AND MASTER CAUTION
LIGHTS ARE OFF AND THAT THERE IS NO
AUDIO SIGNAL.
004

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-50-00
OPT 10000-001
2-400 PAGE
3
DEC 01/14

24-50-00
4

AH

OPERATIONAL TEST OF
ELECTRICAL LOAD
DISTRIBUTION

OPT 10000-001
DEC14

24-50-00
OPT 10000-001

2-400

PAGE
4
DEC 01/14

24-50-00

OPERATIONAL TEST OF AC,


ACW AND DC NORMAL
DISTRIBUTION

OPT 10000-002
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC

: DC AND AC EXTERNAL POWER


SUPPLY
: PRINCIPLE OF CDS USE
(DISPLAY UNITS
EXPLORATION)

AH

24-40-00-EAD-10000
31-63-00-PRO-10000

24-50-00
OPT 10000-002
2-400 PAGE
1
DEC 01/14

24-50-00

OPERATIONAL TEST OF AC,


ACW AND DC NORMAL
DISTRIBUTION

001

OPT 10000-002
2

DEC14

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

002

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

003

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

004

OPERATIONAL TEST OF DIRECT CURRENT AND


______________________________________
ALTERNATIVE CURRENT (CONSTANT AND WILD
______________________________________
FREQUENCY) NORMAL LOAD DISTRIBUTION
___________________________________
REF. FIG. 245000-OPT-00100
1. NOTE: OPERATIONAL TEST OF DIRECT CURRENT
AND ALTERNATIVE CURRENT (CONSTANT AND
WILD FREQUENCY) NORMAL LOAD DISTRIBUTION IS IDENTICAL THROUGHOUT PROCEDURE
BUT EACH CIRCUIT BREAKER C/B COR*** CONTINUED ***
AH

24-50-00
OPT 10000-002
2-400 PAGE
2
DEC 01/14

24-50-00

OPERATIONAL TEST OF AC,


ACW AND DC NORMAL
DISTRIBUTION

OPT 10000-002
3

DEC14

RESPONDS TO A DIFFERENT ANNUNCIATOR


LIGHT AS SHOWN BELOW:
C/B
3XN
4XN
5XB
6XB
7PN
8PN

ANNUNCIATOR LIGHT
MAIN ELEC PWR/AC BUS
MAIN ELEC PWR/AC BUS
AC WILD ELEC PWR/ACW
AC WILD ELEC PWR/ACW
MAIN ELEC PWR/DC BUS
MAIN ELEC PWR/DC BUS

1/BUS OFF/INV
2/BUS OFF/INV
BUS 1/ACW BUS
BUS 2/ACW BUS
1/DC BUS OFF
2/DC BUS OFF

FAULT
FAULT
OFF
OFF

A. ON MAIN ELEC PWR PANEL (29VU) AND AC WILD


ELEC PWR PANEL (26VU), BUS OFF FOR
AC BUS 1 AND 2, ACW BUS OFF FOR
ACW BUS 1 AND 2 AND DC BUS OFF FOR
DC BUS 1 AND 2 CAUTION LIGHTS ARE OFF.
B. ON MFD UPPER WINDOW, IN ELEC
- GREEN AC BUS 1 SYMBOL IS
- GREEN AC BUS 2 SYMBOL IS
- GREEN DC BUS 1 SYMBOL IS
- GREEN DC BUS 2 SYMBOL IS

SD PAGE:
DISPLAYED
DISPLAYED
DISPLAYED
DISPLAYED

C. ON MFD UPPER WINDOW, IN HYD/ACW SD PAGE:


- GREEN ACW BUS 1 SYMBOL IS DISPLAYED
- GREEN ACW BUS 2 SYMBOL IS DISPLAYED
2. TYPICAL TEST FOR A DISTRIBUTION CIRCUIT
A. OPEN CIRCUIT BREAKER C/B:
CHECK THAT:
- ANNUNTIATOR LIGHT COMES ON AMBER.
- ON MFD UPPER WINDOW, IN ELEC SD PAGE
OR HYD/ACW SD PAGE, CORRESPONDING
ITEM IS DISPLAYED IN AMBER
- ON EWD, IN ALERT WINDOW, CORRESPONDING
MESSAGE AND ASSOCIATED PROCEDURE IS
DISPLAYED.
- MASTER CAUTION LIGHTS COME ON.
- SINGLE CHIME SOUNDS AT LOUDSPEAKERS.
*** CONTINUED ***
AH

24-50-00
OPT 10000-002
2-400 PAGE
3
DEC 01/14

24-50-00

OPERATIONAL TEST OF AC,


ACW AND DC NORMAL
DISTRIBUTION

OPT 10000-002
4

DEC14

NOTE :FOR OPERATIONAL TEST OF ALTERNATIVE


CURRENT (WILD FREQUENCY), IF CONDITION
LEVERS ARE BELOW FTR POSITION
- MASTER CAUTION LIGHTS ARE OFF.
- SINGLE CHIME DOESN}T SOUND.
B. CLOSE CIRCUIT BREAKER C/B.
- CHECK THAT ALL ANNUNCIATOR LIGHTS,
MASTER CAUTION LIGHTS ARE OFF AND THAT
THERE IS NO AUDIO SIGNAL.
- CHECK THAT ON EWD, IN ALERT WINDOW,
NO MESSAGES RELATED TO AC OR DC OR
ACW BUSES AND THEIR ASSOCIATED
PROCEDURE ARE DISPLAYED.
- ON MFD UPPER WINDOW, IN ELEC SD PAGE,
OR HYD/ACW SD PAGE, CORRESPONDING
ITEM DISPLAYED IN GREEN.
005

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-50-00
OPT 10000-002
2-400 PAGE
4
DEC 01/14

24-50-00
5

AH

OPERATIONAL TEST OF
ELECTRICAL LOAD
DISTRIBUTION

OPT 10000-002
DEC14

24-50-00
OPT 10000-002

2-400

PAGE
5
DEC 01/14

24-50-00

REMOVAL AND INSTALLATION


OF NORMAL DISTRIBUTION
CIRCUIT RELAYS

RAI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 212
222
: 222PZ 222QZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

SPARE

: 01 RELAY
01 RELAY

___
MEN

5XN AND 6XN


9XB AND 10XB

_________
MAN-HOURS

245180-02-020
245280-02-020

PUBLICATION
___________
JIC

: OPERATIONAL TEST OF AC,


ACW AND DC NORMAL
DISTRIBUTIONS

AH

24-50-00-OPT-10000

24-50-00
RAI 10000-001
2-400 PAGE
1
APR 01/05

24-50-00

REMOVAL AND INSTALLATION


OF NORMAL DISTRIBUTION
CIRCUIT RELAYS

001

RAI 10000-001
2

APR05

DE-ENERGIZATION OF RELAYS 5XN, 6XN, 9XB AND


___________________________________________
10XB.
_____
1. RELAY 9XB
ON CIRCUIT BREAKER PANEL 122VU, OPEN THE
FOLLOWING CIRCUITS BREAKERS :
3XB
ACW ELEC PWR/ACW BUS CAUTION LT/BUS 1
5XB
ACW ELEC PWR/ACW BUS CAUTION RLY/BUS 1
7DA
PROBES HTG/STBY PITOT/EMER SPLY
57DA PROBES HTG/STBY PITOT/NORM SPLY
2. RELAY 10XB
ON CIRCUIT BREAKER PANEL 122VU, OPEN THE
FOLLOWING CIRCUITS BREAKERS :
4XB
ACW ELEC PWR/ACW BUS CAUTION LT/BUS 2
6XB
ACW ELEC PWR/ACW BUS CAUTION RLY/BUS 2
4LF
COMPT LT & SERVICING/FLT COMP/INST &
PNL NORM SPLY
222LF COMPT LT & SERVICING/FLT COMPT/INST
ALTN SPLY
3. RELAYS 5XN AND 6XN
ON CIRCUIT BREAKER PANEL 122VU, OPEN THE
FOLLOWING CIRCUITS BREAKERS :
1XN
MAIN ELEC PWR-AC/AC BUS CAUTION LT/
BUS 1
2XN
MAIN ELEC PWR-AC/AC BUS CAUTION LT/
BUS 2
3XN
MAIN ELEC PWR-AC/AC BUS CAUTION RLY/
BUS 1
4XN
MAIN ELEC PWR-AC/AC BUS CAUTION RLY/
BUS 2

002

________________________________________
REMOVAL
OF RELAYS 5XN, 6XN, 9XB AND 10XB
REF. FIG. 245000-RAI-00100
1. REMOVE ACCESS PANEL 222PZ, TO GAIN ACCESS
TO THE FOLLOWING RELAYS :
ON SHELF 94VU : 9XB, 6XN
*** CONTINUED ***
AH

24-50-00
RAI 10000-001
2-400 PAGE
2
APR 01/05

24-50-00

REMOVAL AND INSTALLATION


OF NORMAL DISTRIBUTION
CIRCUIT RELAYS

2. REMOVE ACCESS
THE FOLLOWING
ON SHELF 92VU
ON SHELF 93VU

RAI 10000-001
3

APR05

PANEL 222QZ TO GAIN ACCESS TO


RELAYS :
: 10XB
: 5XN

3. UNSCREW RELAY ATTACHMENT SCREWS (3).


4. REMOVE RELAY (1) FROM BASE (2) TAKING CARE
NOT TO DAMAGE ELECTRICAL CONNECTORS.
003

_____________________________________________
INSTALLATION
OF RELAYS 5XN, 6XN, 9XB AND 10XB
REF. FIG. 245000-RAI-00100
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA.
2. CHECK FOR CORRECT CONDITION OF ELECTRICAL
CONNECTORS.
3. INSTALL RELAY (1) ON ITS SUPPORT (2).
4. ATTACH ASSEMBLY USING SCREWS (3).
5. INSTALL ACCESS DOORS 222PZ AND 222QZ.

004

_____________________________________________
ENERGIZATION
OF RELAYS 5XN, 6XN, 9XB AND 10XB
1. RELAY 9XB
ON CIRCUIT BREAKER PANEL 122VU, CLOSE THE
FOLLOWING CIRCUIT BREAKER :
3XB
ACW ELEC PWR/ACW BUS CAUTION LT/BUS 1
5XB
ACW ELEC PWR/ACW BUS CAUTION RLY/BUS 1
7DA
PROBES HTG/STBY PITOT/EMER SPLY
57DA PROBES HTG/STBY PITOT/NORM SPLY
2. RELAY 10XB
ON CIRCUIT BREAKER PANEL 122VU, CLOSE THE
FOLLOWING CIRCUIT BREAKER :
4XB
ACW ELEC PWR/ACW BUS CAUTION LT/BUS 2
6XB
ACW ELEC PWR/ACW BUS CAUTION RLY/BUS 2
*** CONTINUED ***
AH

24-50-00
RAI 10000-001
2-400 PAGE
3
APR 01/05

24-50-00

REMOVAL AND INSTALLATION


OF NORMAL DISTRIBUTION
CIRCUIT RELAYS

RAI 10000-001
4

APR05

4LF

COMPT LT & SERVICING/FLT COMP/INST &


PNL NORM SPLY
222LF COMPT LT & SERVICING/FLT COMPT/INST
ALTN SPLY
3. RELAYS 5XN AND 6XN
ON CIRCUIT BREAKER PANEL 122VU, CLOSE
FOLLOWING CIRCUIT BREAKER :
1XN
MAIN ELEC PWR-AC/AC BUS CAUTION
BUS 1
2XN
MAIN ELEC PWR-AC/AC BUS CAUTION
BUS 2
3XN
MAIN ELEC PWR-AC/AC BUS CAUTION
BUS 1
4XN
MAIN ELEC PWR-AC/AC BUS CAUTION
BUS 2
005

THE
LT/
LT/
RLY/
RLY/

TEST OF RELAYS 5XN, 6XN, 9XB, 10XB, 11PN AND


____________________________________________
12PN
____
SEE JOB INSTRUCTION CARD
245000-OPT-10000
*****

AH

E N D

O F

T E X T

*****

24-50-00
RAI 10000-001
2-400 PAGE
4
APR 01/05

24-50-00
5

AH

RELAYS 5XN, 6XN, 9XB


AND 10XB

RAI 10000-001
APR05

24-50-00
RAI 10000-001

2-400

PAGE
5
APR 01/05

24-65-00

OPERATIONAL TEST OF STBY


OVERRIDE FUNCTION AND
ASSOCIATED INDICATING

OPT 10000-002
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC

: POWER SUPPLY FROM


BATTERIES
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY

AH

24-31-00-EAD-10000
45-13-00-RDG-10000
45-13-00-RON-10000

24-65-00
OPT 10000-002
2-400 PAGE
1
DEC 01/14

24-65-00

OPERATIONAL TEST OF STBY


OVERRIDE FUNCTION AND
ASSOCIATED INDICATING

001

OPT 10000-002
2

DEC14

_________________________________
ENERGIZING
OF SYSTEM FROM BATTERY
SEE JOB INSTRUCTION CARD
243100-EAD-10000

002

___________
PREPARATION
NOTE:TO CONTINUE THIS TASK, DO NOT TAKE INTO
ACCOUNT THE ENERGIZATION AND DE-ENERGIZATION FROM THE GROUND POWER UNIT.
WITH THE BELOW PROCEDURE, CHECK IF:
ELEC:STBY CONTACTOR DEFAULT
IS RECORDED IN THE MFC MAINTENANCE MEMORY.

003

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

004

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
NOTE:THIS TASK MUST BE PERFORMED ONLY IF FAULTS
RELATIVE TO THE SYSTEM TO BE CHECKED HAVE
BEEN RECORDED BY THE MFC MAINTENANCE
MEMORY.

005

OPERATIONAL TEST OF STANDBY OVERRIDE


____________________________________
FUNCTION AND ASSOCIATED INDICATING
__________________________________
REF. FIG. 246500-OPT-00100
1. ON C/B PANEL 129VU, OPEN THE FOLLOWING
CIRCUIT BREAKERS :
4XA INV 1 ON HOT MAIN BAT BUS
3PD DC STBY BUS ON HMBB
2. ON MAIN ELEC PWR PANEL 29VU,
*** CONTINUED ***
AH

24-65-00
OPT 10000-002
2-400 PAGE
2
DEC 01/14

24-65-00

OPERATIONAL TEST OF STBY


OVERRIDE FUNCTION AND
ASSOCIATED INDICATING

OPT 10000-002
3

DEC14

A. MAKE CERTAIN THAT BUS OFF FOR AC BUS 1,


INV FAULT FOR INV 1 CAUTION LIGHTS AND
UNDV LEGEND OF OVRD/UNDV PUSHBUTTON
SWITCH 9PD COME ON.
B. PRESS OVRD/UNDV PUSHBUTTON SWITCH 9PD
- OVRD LEGEND COMES ON,
- UNDV LEGEND GOES OFF,
- INV FAULT FOR INV 1 CAUTION LIGHT
GOES OFF.
3. ON C/B PANEL 129VU, CLOSE THE FOLLOWING
CIRCUIT BREAKERS :
4XA INV 1 ON HOT MAIN BAT BUS
3PD DC STBY BUS ON HMBB
4. ON PANEL 29VU,
RELEASE OVRD/UNDV PUSHBUTTON SWITCH 9PD AND
MAKE CERTAIN THAT OVRD LEGEND GOES OFF
WHILST INV FAULT AND UNDV LEGENDS REMAIN
OFF.
5. WITH BELOW PROCEDURE, MAKE CERTAIN THAT:
ELEC:STBY CONTACTOR DEFAULT
IS NOT RECORDED IN MFC MAINTENANCE MEMORY.
006

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

007

OPERATIONAL TEST OF STANDBY OVERRIDE


____________________________________
FUNCTION AND ASSOCIATED INDICATING
__________________________________
REF. FIG. 246500-OPT-00100
1. ON C/B PANEL 122VU, OPEN AND CLOSE AFTER
4 SEC THE CIRCUIT BREAKER :
8PD MAIN ELEC PWR-DC/STBY BUS/CTL
2. WITH BELOW PROCEDURE, MAKE CERTAIN THAT:
*** CONTINUED ***
AH

24-65-00
OPT 10000-002
2-400 PAGE
3
DEC 01/14

24-65-00

OPERATIONAL TEST OF STBY


OVERRIDE FUNCTION AND
ASSOCIATED INDICATING

OPT 10000-002
4

DEC14

ELEC:STBY CONTACTOR DEFAULT


IS RECORDED IN MFC MAINTENANCE MEMORY.
008

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

009

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000

010

____________________________________
DE-ENERGIZING
OF SYSTEM FROM BATTERY
SEE JOB INSTRUCTION CARD
243100-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-65-00
OPT 10000-002
2-400 PAGE
4
DEC 01/14

24-65-00
5

AH

OPERATIONNAL TEST OF
STBY DISTRIBUTION AND
ASSOCIATED INDICATING

OPT 10000-002
DEC14

24-65-00
OPT 10000-002

2-400

PAGE
5
DEC 01/14

24-65-00

OPERATIONAL TEST OF STBY


OVERRIDE FUNCTION AND
ASSOCIATED INDICATING

OPT 10000-003
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC

: POWER SUPPLY FROM


BATTERIES
: PRINCIPLE OF CDS USE
(DISPLAY UNITS
EXPLORATION)
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY

AH

24-31-00-EAD-10000
31-63-00-PRO-10000
45-13-00-RDG-10000
45-13-00-RON-10000

24-65-00
OPT 10000-003
2-400 PAGE
1
DEC 01/14

24-65-00

OPERATIONAL TEST OF STBY


OVERRIDE FUNCTION AND
ASSOCIATED INDICATING

001

OPT 10000-003
2

DEC14

_________________________________
ENERGIZING
OF SYSTEM FROM BATTERY
SEE JOB INSTRUCTION CARD
243100-EAD-10000

002

___________
PREPARATION
NOTE:TO CONTINUE THIS TASK, DO NOT TAKE INTO
ACCOUNT THE ENERGIZATION AND DE-ENERGIZATION FROM THE GROUND POWER UNIT.
WITH THE BELOW PROCEDURE, CHECK IF:
ELEC:STBY CONTACTOR DEFAULT
IS RECORDED IN THE MFC MAINTENANCE MEMORY.

003

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

004

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

005

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
NOTE:THIS TASK MUST BE PERFORMED ONLY IF FAULTS
RELATIVE TO THE SYSTEM TO BE CHECKED HAVE
*** CONTINUED ***
AH

24-65-00
OPT 10000-003
2-400 PAGE
2
DEC 01/14

24-65-00

OPERATIONAL TEST OF STBY


OVERRIDE FUNCTION AND
ASSOCIATED INDICATING

OPT 10000-003
3

DEC14

BEEN RECORDED BY THE MFC MAINTENANCE


MEMORY.
006

OPERATIONAL TEST OF STANDBY OVERRIDE


____________________________________
FUNCTION AND ASSOCIATED INDICATING
__________________________________
REF. FIG. 246500-OPT-00100
1. ON C/B PANEL 129VU, OPEN THE FOLLOWING
CIRCUIT BREAKERS:
4XA INV 1 ON HOT MAIN BAT BUS
3PD DC STBY BUS ON HMBB
2. VERIFY THAT:
A. ON MAIN ELEC PWR PANEL 29VU
MAKE CERTAIN THAT BUS OFF FOR AC BUS 1,
INV FAULT FOR INV 1 CAUTION LIGHTS
AND UNDV LEGEND OF OVRD/UNDV
PUSHBUTTON SWITCH COMES ON.
B. ON MFD UPPER WINDOW, IN ELEC SD PAGE,
- AMBER INV 1 SYMBOL IS DISPLAYED
- UNDV LEGEND ON DC STBY BUS SYMBOL
IS DISPLAYED
NOTE: DO NOT PAY ATTENTION TO OTHER
SYMBOLS.
C. ON 29VU,PRESS OVRD/UNDV PUSHBUTTON SWITCH
- OVRD LEGEND COMES ON,
- UNDV LEGEND GOES OFF,
- INV FAULT FOR INV 1 CAUTION
LIGHT GOES OFF.
ON MFD UPPER WINDOW, IN ELEC SD PAGE
- GREEN INV 1 SYMBOL IS DISPLAYED
- UNDV LEGEND ON DC STBY BUS SYMBOL
IS NOT DISPLAYED
- OVRD LEGEND ON DC STBY BUS SYMBOL
IS DISPLAYED
3. ON C/B PANEL 129VU, CLOSE THE FOLLOWING
CIRCUIT BREAKERS:
4XA INV 1 ON HOT MAIN BAT BUS
3PD DC STBY BUS ON HMBB
*** CONTINUED ***
AH

24-65-00
OPT 10000-003
2-400 PAGE
3
DEC 01/14

24-65-00

OPERATIONAL TEST OF STBY


OVERRIDE FUNCTION AND
ASSOCIATED INDICATING

OPT 10000-003
4

DEC14

A. ON PANEL 29VU,
RELEASE OVRD/UNDV PUSHBUTTON SWITCH AND
MAKE CERTAIN THAT OVRD LEGEND GOES OFF
WHILST INV FAULT AND UNDV LEGENDS
REMAIN OFF.
B. ON MFD UPPER WINDOW, IN ELEC SD PAGE,
VERIFY THAT:
- GREEN INV 1 SYMBOL IS DISPLAYED
- UNDV LEGEND ON DC STBY BUS SYMBOL
IS NO MORE DISPLAYED
- OVRD LEGEND ON DC STBY BUS SYMBOL
IS NO MORE DISPLAYED
4. WITH BELOW PROCEDURE, MAKE CERTAIN THAT:
ELEC: STBY CONTACTOR DEFAULT
IS NOT RECORDED IN MFC MAINTENANCE MEMORY.
007

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

008

OPERATIONAL TEST OF STANDBY OVERRIDE


____________________________________
FUNCTION AND ASSOCIATED INDICATING
__________________________________
REF. FIG. 246500-OPT-00100
1. ON C/B PANEL 122VU, OPEN AND CLOSE AFTER
4 SEC THE CIRCUIT BREAKER :
8PD MAIN ELEC PWR-DC/STBY BUS/CTL
2. WITH BELOW PROCEDURE, MAKE CERTAIN THAT:
ELEC:STBY CONTACTOR DEFAULT
IS RECORDED IN MFC MAINTENANCE MEMORY.

009

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

*** CONTINUED ***


AH

24-65-00
OPT 10000-003
2-400 PAGE
4
DEC 01/14

24-65-00

OPERATIONAL TEST OF STBY


OVERRIDE FUNCTION AND
ASSOCIATED INDICATING

010

OPT 10000-003
5

DEC14

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000

011

____________________________________
DE-ENERGIZING
OF SYSTEM FROM BATTERY
SEE JOB INSTRUCTION CARD
243100-EAD-10000
*****

AH

E N D

O F

T E X T

*****

24-65-00
OPT 10000-003
2-400 PAGE
5
DEC 01/14

24-65-00
6

AH

OPERATIONNAL TEST OF
STBY DISTRIBUTION AND
ASSOCIATED INDICATING

OPT 10000-003
DEC14

24-65-00
OPT 10000-003

2-400

PAGE
6
DEC 01/14

24-65-81

REMOVAL AND INSTALLATION


OF CONTACTORS 4PD AND
13PD

RAI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 212
: 212VZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

_________
MAN-HOURS

ELAPSED TIME

SPARE

: 01 CONTACTOR 4PD AND 13PD

246580-01-120

: OPERATIONAL TEST OF STBY


OVERRIDE FUNCTION AND
ASSOCIATED INDICATING

24-65-00-OPT-10000

PUBLICATION
___________
JIC

AH

24-65-81
RAI 10000-001
2-400 PAGE
1
APR 01/05

24-65-81

REMOVAL AND INSTALLATION


OF CONTACTORS 4PD AND
13PD

001

RAI 10000-001
2

APR05

__________________________________________
DE-ENERGIZATION
OF CONTACTORS 4PD AND 13PD
REF. FIG. 246581-RAI-00100
OPEN SAFETY AND TAG THE FOLLOWING CIRCUIT
BREACKERS :
ON PANEL 122VU
8PD MAIN ELEC PWR-DC/STBY BUS/CTL
ON PANEL 127VU
3XA PWR SPLY ON PRIM DC BUS 1/INV 1
ON PANEL 129VU
3PD DC STBY BUS ON HMBB
4XA INV 1 ON HOT MAIN BAT BUS
ON PANEL 130VU
11PD DC EMER & STBY BUS ON HEBB/DC STBY BUS
60PA DC EMER BUS/INV 1 ON HEBB IND
7XA INV 1 ON HOT EMER BAT BUS

002

___________
PREPARATION
REF. FIG. 246581-RAI-00100
1. REMOVE ACCESS PANEL 212VZ.
2. DETACH PANEL 130VU FROM 123VU WITHOUT
REMOVING IT.

003

__________________________________
REMOVAL
OF CONTACTORS 4PD AND 13PD
REF. FIG. 246581-RAI-00100
1. REMOVE NUTS (1) AND (7), WASHERS (2) AND BAR
(3). IDENTIFY AND DISCONNECT TERMINAL LUGS
(4).
2. LOOSEN SCREWS (5).
3. DISCONNECT CONTACTOR (6).
4. INSTALL PROTECTIVE CAPS ON CONNECTORS (8).
*** CONTINUED ***
AH

24-65-81
RAI 10000-001
2-400 PAGE
2
APR 01/05

24-65-81

REMOVAL AND INSTALLATION


OF CONTACTORS 4PD AND
13PD

004

RAI 10000-001
3

APR05

_______________________________________
INSTALLATION
OF CONTACTORS 4PD AND 13PD
REF. FIG. 246581-RAI-00100
1. CLEAN AND INSPECT CONTACTOR (6) INTERFACE
AND/OR ADJACENT AREA.
2. REMOVE PROTECTIVE CAPS FROM CONNECTORS (8).
3. MAKE CERTAIN THAT CONTACTS ARE IN CORRECT
CONDITION.
4. CONNECT CONTACTOR (6).
5. TIGHTEN SCREW (5).
6. CONNECT TERMINAL LUGS (4), INSTALL BAR (3),
WASHERS (2) SCREW AND TORQUE
- NUTS (1) TO 0,35 M.DAN (31 LBF.IN)
- NUTS (7) TO 0,20 M.DAN (17.5 LBF.IN).

005

________
CLOSE-UP
REF. FIG. 246581-RAI-00100
1. PLACE PANEL 130VU ON 123VU AND ATTACH.
2. FIX ACCESS PANEL 212VZ.

006

_______________________________________
ENERGIZATION
OF CONTACTORS 4PD AND 13PD
REF. FIG. 246581-RAI-00100
REMOVE SAFETY CLIPS AND CLOSE THE FOLLOWING
CIRCUIT BREACKERS :
ON PANEL 122VU
8PD MAIN ELEC PWR-DC/STBY BUS/CTL
ON PANEL 127VU
3XA PWR SPLY ON PRIM DC BUS 1/INV 1
ON PANEL 129VU
3PD DC STBY BUS ON HMBB
*** CONTINUED ***
AH

24-65-81
RAI 10000-001
2-400 PAGE
3
APR 01/05

24-65-81

REMOVAL AND INSTALLATION


OF CONTACTORS 4PD AND
13PD

RAI 10000-001
4

APR05

4XA INV 1 ON HOT MAIN BAT BUS


ON PANEL 130VU
11PD DC EMER & STBY BUS ON HEBB/DC STBY BUS
60PA DC EMER BUS/INV 1 ON HEBB IND
7XA INV 1 ON HOT EMER BAT BUS
007

________________________________________
TEST
CONTACTORS 4PD , 13PD AND RELAY 7PD
SEE JOB INSTRUCTION CARD
246500-OPT-10000
*****

AH

E N D

O F

T E X T

*****

24-65-81
RAI 10000-001
2-400 PAGE
4
APR 01/05

24-65-81
5

AH

CONTACTORS 4PD AND 13PD

RAI 10000-001
APR05

24-65-81
RAI 10000-001

2-400

PAGE
5
APR 01/05

24-70-00

BONDING INSPECTION

MSN 10000-002
1

DEC14

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

GSE

: 01 MEGOHMMETER
01 MILLIOHMETER

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC

: REMOVAL/INSTALLATION
OF RADOME

AH

53-91-21-RAI-10000

24-70-00
MSN 10000-002
2-400 PAGE
1
DEC 01/14

24-70-00

BONDING INSPECTION

MSN 10000-002
2

001

DEC14

___________
PREPARATION
THE AIRCRAFT MUST BE CONNECTED NEITHER TO THE
GROUND POWER UNIT NOR TO THE GROUND. IT MUST BE
ON ITS WHEELS, DRY AND IN A SHELTERED AREA. THE
DOORS MUST BE CLOSED.
SAFETY DEVICES AND WARNING NOTICES MUST BE
INSTALLED. THE AIRCRAFT ELECTRICAL NETWORK MUST
NOT BE ENERGIZED.
ACCESS PLATFORMS MUST BE INSTALLED IN THE
INSPECTION AREA.

002

_________________
REMOVAL
OF RADOME
SEE JOB INSTRUCTION CARD
539121-RAI-10000

003

RADOME ANTI-STATIC PROTECTION CHECK


___________________________________
(ANTI-STATIC PAINT)
___________________
REF. FIG. 247000-MSN-00105
1. USING A MEGOHMMETER, MEASURE THE RESISTIVITY
VALUE BETWEEN EACH LIGHTNING ARRESTOR STRIP.
PERFORM THESE MEASUREMENTS FROM THE RADOME
GROUNDING SPRINGS.
2. RECORD THESE VALUES :
R1 =
MEGOHMS
R2 =
MEGOHMS
R3 =
MEGOHMS
R4 =
MEGOHMS
R5 =
MEGOHMS
R6 =
MEGOHMS
3. CALCULATE THE AVERAGE VALUE :
R=(R1+R2+R3+R4+R5+R6)/6 =
MEGOHMS
- THE AVERAGE VALUE R MUST BE LOCATED
BETWEEN 5 AND 200 MEGOHMS.
*** CONTINUED ***
AH

24-70-00
MSN 10000-002
2-400 PAGE
2
DEC 01/14

BONDING INSPECTION

24-70-00

MSN 10000-002
3

004

DEC14

___________________________________________
VALIDATION
OF A (PT) SECONDARY GROUND POINT
REF. FIG. 247000-MSN-00100
THE (PR) FRAME-01 REFERENCE GROUND POINTS
(STRUCTURAL BASES OF RADOME GROUNDING SPRINGS)
BEING NO MORE ACCESSIBLE WHEN THE RADOME IS
INSTALLED, IT IS NECESSARY TO DEFINE A (PT)
SECONDARY GROUND POINT ON THE NLG DOOR
BONDING BRAID FOR THE CONTINUITY MEASUREMENTS.
1. USING A MILLIOHMETER, CHECK THE RESISTANCE
VALUE BETWEEN ONE (PR)(FRAME-01) REFERENCE
GROUND POINT AND THE (PT) SECONDARY
REFERENCE POINT.
- VALUE MUST BE LESS THAN 2 MILLIOHMS.

005

______________________
INSTALLATION
OF RADOME
SEE JOB INSTRUCTION CARD
539121-RAI-10000

006

________________________
BONDING
CONTINUITY CHECK
NOTE : THIS BONDING CONTINUITY MEASUREMENT IS
PERFORMED WITH RESPECT TO THE (PT)
SECONDARY REFERENCE GROUND POINT
PREVIOUSLY DEFINED.
REF. FIG. 247000-MSN-00105
1. RADOME :
USING A MILLIOHMETER, MESURE, FOR EACH
LIGHTNING ARRESTOR STRIP, THE CONTINUITY
VALUE BETWEEN A BONDING PICK-UP SCREW
AND THE (PT) SECONDARY REFERENCE POINT.
- FOR EACH OF THESE MEASUREMENTS, THE
VALUE MUST BE 4 MILLIOHMS MAXI.
NOTE : IF THE LIGHTNING ARRESTOR STRIPS ARE
PAINTED, REMOVE THE SCREW IN ORDER
TO ACCESS TO A METALLICAL PART
*** CONTINUED ***
AH

24-70-00
MSN 10000-002
2-400 PAGE
3
DEC 01/14

24-70-00

BONDING INSPECTION

MSN 10000-002
4

DEC14

(THREADING).
REF. FIG. 247000-MSN-00105
2. TAIL CONE :
USING A MILLIOHMETER, MESURE, FOR EACH
LIGHTNING ARRESTOR STRIP, THE CONTINUITY
VALUE BETWEEN THE ATTACHMENT SCREW AND
THE (PT) SECONDARY REFERENCE POINT.
- FOR EACH OF THESE MEASUREMENTS, THE
VALUE MUST BE 4 MILLIOHMS MAXI.
NOTE : IF THE LIGHTNING ARRESTOR STRIPS ARE
PAINTED, REMOVE THE SCREW IN ORDER
TO ACCESS TO A METALLICAL PART
(THREADING).
007

________
CLOSE-UP
1. INSTALL THE SCREWS PREVIOUSLY REMOVED ON
RADOME AND TAIL CONE.
2. MAKE CERTAIN THAT ACCESS PANELS RADOME AND
ENGINE COWLS ARE CORRECTLY LOCKED.
3. REMOVE ACCESS PLATFORM FROM WORK AREA.
4. REMOVE WARNING NOTICES.
*****

AH

E N D

O F

T E X T

*****

24-70-00
MSN 10000-002
2-400 PAGE
4
DEC 01/14

24-70-00
5

AH

VALIDATION OF A
SECONDARY GROUND POINT

MSN 10000-002
DEC14

24-70-00
MSN 10000-002

2-400

PAGE
5
DEC 01/14

24-70-00
6

AH

BONDING MEASUREMENTS
OF RADOME AND TAIL
CONE

MSN 10000-002
DEC14

24-70-00
MSN 10000-002

2-400

PAGE
6
DEC 01/14

24-70-00

BONDING INSPECTION

MSN 10000-003
1

MAR14

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

GSE

: 01 MEGOHMMETER
01 MILLIOHMETER

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC

: REMOVAL/INSTALLATION
OF RADOME

AH

53-91-21-RAI-10000

24-70-00
MSN 10000-003
2-400 PAGE
1
MAR 01/14

24-70-00

BONDING INSPECTION

MSN 10000-003
2

001

MAR14

___________
PREPARATION
THE AIRCRAFT MUST BE CONNECTED NEITHER TO THE
GROUND POWER UNIT NOR TO THE GROUND. IT MUST BE
ON ITS WHEELS, DRY AND IN A SHELTERED AREA. THE
DOORS MUST BE CLOSED.
SAFETY DEVICES AND WARNING NOTICES MUST BE
INSTALLED. THE AIRCRAFT ELECTRICAL NETWORK MUST
NOT BE ENERGIZED.
ACCESS PLATFORMS MUST BE INSTALLED IN THE
INSPECTION AREA.

002

_________________
REMOVAL
OF RADOME
SEE JOB INSTRUCTION CARD
539121-RAI-10000

003

RADOME ANTI-STATIC PROTECTION CHECK


___________________________________
(ANTI-STATIC PAINT)
___________________
REF. FIG. 247000-MSN-00105
1. USING A MEGOHMMETER, MEASURE THE RESISTIVITY
VALUE BETWEEN EACH LIGHTNING ARRESTOR STRIP.
PERFORM THESE MEASUREMENTS FROM THE RADOME
GROUNDING SPRINGS.
2. RECORD THESE VALUES :
R1 =
MEGOHMS
R2 =
MEGOHMS
R3 =
MEGOHMS
R4 =
MEGOHMS
R5 =
MEGOHMS
R6 =
MEGOHMS
3. CALCULATE THE AVERAGE VALUE :
R=(R1+R2+R3+R4+R5+R6)/6 =
MEGOHMS
- THE AVERAGE VALUE R MUST BE LOCATED
BETWEEN 5 AND 200 MEGOHMS.
*** CONTINUED ***
AH

24-70-00
MSN 10000-003
2-400 PAGE
2
MAR 01/14

BONDING INSPECTION

24-70-00

MSN 10000-003
3

004

MAR14

___________________________________________
VALIDATION
OF A (PT) SECONDARY GROUND POINT
REF. FIG. 247000-MSN-00100
THE (PR) FRAME-01 REFERENCE GROUND POINTS
(STRUCTURAL BASES OF RADOME GROUNDING SPRINGS)
BEING NO MORE ACCESSIBLE WHEN THE RADOME IS
INSTALLED, IT IS NECESSARY TO DEFINE A (PT)
SECONDARY GROUND POINT ON THE NLG DOOR
BONDING BRAID FOR THE CONTINUITY MEASUREMENTS.
1. USING A MILLIOHMETER, CHECK THE RESISTANCE
VALUE BETWEEN ONE (PR)(FRAME-01) REFERENCE
GROUND POINT AND THE (PT) SECONDARY
REFERENCE POINT.
- VALUE MUST BE LESS THAN 2 MILLIOHMS.

005

______________________
INSTALLATION
OF RADOME
SEE JOB INSTRUCTION CARD
539121-RAI-10000

006

________________________
BONDING
CONTINUITY CHECK
NOTE : THIS BONDING CONTINUITY MEASUREMENT IS
PERFORMED WITH RESPECT TO THE (PT)
SECONDARY REFERENCE GROUND POINT
PREVIOUSLY DEFINED.
REF. FIG. 247000-MSN-00105
1. RADOME :
USING A MILLIOHMETER, MESURE, FOR EACH
LIGHTNING ARRESTOR STRIP, THE CONTINUITY
VALUE BETWEEN A BONDING PICK-UP SCREW
AND THE (PT) SECONDARY REFERENCE POINT.
- FOR EACH OF THESE MEASUREMENTS, THE
VALUE MUST BE 4 MILLIOHMS MAXI.
NOTE : IF THE LIGHTNING ARRESTOR STRIPS ARE
PAINTED, REMOVE THE SCREW IN ORDER
TO ACCESS TO A METALLICAL PART
*** CONTINUED ***
AH

24-70-00
MSN 10000-003
2-400 PAGE
3
MAR 01/14

24-70-00

BONDING INSPECTION

MSN 10000-003
4

MAR14

(THREADING).
REF. FIG. 247000-MSN-00105
2. TAIL CONE :
USING A MILLIOHMETER, MESURE, FOR EACH
LIGHTNING ARRESTOR STRIP, THE CONTINUITY
VALUE BETWEEN THE ATTACHMENT SCREW AND
THE (PT) SECONDARY REFERENCE POINT.
- FOR EACH OF THESE MEASUREMENTS, THE
VALUE MUST BE 4 MILLIOHMS MAXI.
NOTE : IF THE LIGHTNING ARRESTOR STRIPS ARE
PAINTED, REMOVE THE SCREW IN ORDER
TO ACCESS TO A METALLICAL PART
(THREADING).
007

________
CLOSE-UP
1. INSTALL THE SCREWS PREVIOUSLY REMOVED ON
RADOME AND TAIL CONE.
2. MAKE CERTAIN THAT ACCESS PANELS RADOME AND
ENGINE COWLS ARE CORRECTLY LOCKED.
3. REMOVE ACCESS PLATFORM FROM WORK AREA.
4. REMOVE WARNING NOTICES.
*****

AH

E N D

O F

T E X T

*****

24-70-00
MSN 10000-003
2-400 PAGE
4
MAR 01/14

24-70-00
5

AH

VALIDATION OF A
SECONDARY GROUND POINT

MSN 10000-003
MAR14

24-70-00
MSN 10000-003

2-400

PAGE
5
MAR 01/14

24-70-00
6

AH

BONDING MEASUREMENTS
OF RADOME AND TAIL
CONE

MSN 10000-003
MAR14

24-70-00
MSN 10000-003

2-400

PAGE
6
MAR 01/14

12 - MAR 01/15

24-00-00-RAI-10000-001
24-00-00-RAI-10000-002
24-00-00-RAI-10010-002
24-21-85-RAI-10000-001
24-32-61-CHK-10000-002
24-32-61-CHK-10000-003
24-32-61-CHK-10005-001
24-32-61-CHK-10005-002
24-32-61-CHK-10006-001
24-32-61-CHK-10006-002
24-32-61-RAI-10000-001
24-32-61-RAI-10000-002
24-32-61-RAI-10010-001
24-32-61-RAI-10010-002
24-32-83-RAI-10000-001
24-32-87-RAI-10000-001
24-46-84-RAI-10000-001

AH

TASK DELETED
NEW TASK
MINOR INFORMATION
MINOR INFORMATION
TASK DELETED
NEW TASK
TASK DELETED
NEW TASK
TASK DELETED
NEW TASK
TASK DELETED
NEW TASK
TASK DELETED
NEW TASK
MINOR INFORMATION
MINOR INFORMATION
MINOR INFORMATION

ADDITION
ADDITION

ADDITION
ADDITION
ADDITION

ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL

12
PAGE
1
MAR 01/15

PAGE

1 TO

5 APR/05

ALL

1 TO

7 APR/05

ALL

TO

DEC/14

ALL

1 TO

7 MAR/15

ALL

1 TO

36 MAR/15

ALL

1 TO

5 APR/05

ALL

1 TO

7 MAR/13

ALL

1 TO

9 DEC/14

51 TO

62

1 TO

11 DEC/14

63 TO

65

1 TO

6 APR/05

ALL

1 TO

7 MAR/15

ALL

1 TO

8 MAR/14

ALL

1 TO

3 DEC/14

51 TO

62

1 TO

4 DEC/14

63 TO

65

1 TO

4 MAR/13

ALL

REVISION NO 12 - MAR/15

24-00-00-CHK-10010-001 VISUAL CHECK OF AC


FEEDER SEATH CONDITION
AT CONNECTIONS
24-00-00-CHK-10020-001 VISUAL CHECK OF DC
FEEDER SHEATH CONDITION
AT CONNECTIONS
24-00-00-RAI-10000-001 REMOVAL AND INSTALLATION
OF CURRENT TRANSFORMERS
IN 120VU
24-00-00-RAI-10000-002 REMOVAL AND INSTALLATION
OF CURRENT TRANSFORMERS
IN 120VU
24-00-00-RAI-10010-002 REMOVAL AND INSTALLATION
OF EQUIPMENT IN 120VU
24-00-00-RAI-10040-001 REMOVAL AND INSTALLATION
OF CONTACTORS AND RELAYS
IN FLIGHT COMPARTMENT
24-00-00-RAI-10060-001 REMOVAL AND INSTALLATION
OF HALL EFFECT SENSORS
IN NACELLE
24-21-00-OPT-10000-001 AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST
24-21-00-OPT-10000-002 AC CONSTANT FREQUENCY
GENERATION OPERATIONAL
TEST
24-21-81-RAI-10000-001 STATIC INVERTER REMOVAL
AND INSTALLATION
24-21-85-RAI-10000-001 REMOVAL AND INSTALLATION
OF AC STBY BUSES
TRANSFER RELAY
24-22-61-RAI-10000-001 ACW GENERATOR 1/2
REMOVAL AND INSTALLATION
24-22-83-OPT-10000-001 ACW BUS TIE CONTACTOR
OPERATIONAL TEST
24-22-83-OPT-10000-002 ACW BUS TIE CONTACTOR
OPERATIONAL TEST
24-22-84-OPT-10000-001 ACW GEN CONTROL UNIT
OPERATIONAL TEST

N
R

AH

1
MAR/15

PAGE

1 TO

5 APR/06

ALL

1 TO

4 DEC/14

51 TO

62

1 TO

5 DEC/14

63 TO

65

1 TO

4 DEC/14

51 TO

62

1 TO

5 DEC/14

63 TO

65

1 TO

7 DEC/14

51 TO

58

1 TO

7 DEC/14

59 TO

62

1 TO

8 DEC/14

63 TO

65

1 TO

6 DEC/14

51 TO

62

1 TO

7 DEC/14

63 TO

65

1 TO

5 DEC/14

51 TO

62

1 TO

7 DEC/14

63 TO

65

1 TO

5 DEC/14

51 TO

62

1 TO

6 DEC/14

63 TO

65

1 TO

6 DEC/14

ALL

1 TO
1 TO
1 TO

4 DEC/14
4 DEC/14
7 DEC/14

51 TO
63 TO
51 TO

62
65
62

1 TO

7 DEC/14

63 TO

65

REVISION NO 12 - MAR/15

24-22-84-RAI-10000-001 ACW GEN CONTROL UNIT


REMOVAL AND INSTALLATION
24-31-00-EAD-10000-001 POWER SUPPLY FROM
BATTERIES
24-31-00-EAD-10000-003 POWER SUPPLY FROM
BATTERIES
24-31-00-OPT-10000-001 OPERATIONAL TEST OF DC
BATTERY TRANSFER RELAYS
24-31-00-OPT-10000-002 OPERATIONAL TEST OF DC
BATTERY TRANSFER RELAYS
24-31-00-OPT-10010-001 OPERATIONAL TEST OF
BATTERY OVRD AND EMER
INDICATING
24-31-00-OPT-10010-002 OPERATIONAL TEST OF
BATTERY OVRD AND EMER
INDICATING
24-31-00-OPT-10010-003 OPERATIONAL TEST OF
BATTERY OVRD AND EMER
INDICATING
24-31-00-OPT-10020-002 OPERATIONAL TEST OF
BATTERY FAULT
INDICATING
24-31-00-OPT-10020-003 OPERATIONAL TEST OF
BATTERY FAULT
INDICATING
24-31-81-OPT-10000-001 OPERATIONAL TEST OF TRU
AND ASSOCIATED CIRCUIT
24-31-81-OPT-10000-002 OPERATIONAL TEST OF TRU
AND ASSOCIATED CIRCUIT
24-31-81-OPT-10005-002 OPERATIONAL TEST OF TRU
AND ASSOCIATED CIRCUIT
(WITH AC EXT PWR SPLY)
24-31-81-OPT-10005-003 OPERATIONAL TEST OF TRU
AND ASSOCIATED CIRCUIT
(WITH AC EXT PWR SPLY)
24-31-81-RAI-10000-002 REMOVAL AND INSTALLATION
OF T R U
24-31-85-CHK-10000-002 CHECK OF BATTERY VOLTAGE
24-31-85-CHK-10000-003 CHECK OF BATTERY VOLTAGE
24-31-85-RAI-10010-003 MAIN BATTERY REMOVAL AND
INSTALLATION
24-31-85-RAI-10010-004 MAIN BATTERY REMOVAL AND
INSTALLATION

AH

2
MAR/15

PAGE

1 TO

6 DEC/14

51 TO

62

1 TO

5 DEC/14

63 TO

65

1 TO

8 DEC/14

51 TO

62

1 TO

9 DEC/14

63 TO

65

TO

MAR/11

ALL

1 TO

2 MAR/15

ALL

TO

MAR/14

ALL

1 TO

7 MAR/15

ALL

TO

MAR/14

ALL

1 TO

7 MAR/15

ALL

TO

MAR/14

ALL

1 TO

10 MAR/15

ALL

TO

DEC/14

ALL

1 TO

3 MAR/15

ALL

1 TO

3 MAR/13

ALL

1 TO

6 APR/07

ALL

1 TO

7 MAR/15

ALL

1 TO

8 MAR/15

ALL

REVISION NO 12 - MAR/15

24-31-85-RAI-10020-004 EMER BATTERY REMOVAL AND


INSTALLATION
24-31-85-RAI-10020-006 EMER BATTERY REMOVAL AND
INSTALLATION
24-32-00-OPT-10000-001 OPT OF DC AND ACW GEN
DE-ENERGIZATION BY FIRE
HANDLE
24-32-00-OPT-10000-002 OPT OF DC AND ACW GEN
DE-ENERGIZATION BY FIRE
HANDLE
24-32-61-CHK-10000-002 CHECK OF STARTER
GENERATOR BRUSHES WEAR
24-32-61-CHK-10000-003 CHECK OF STARTER
GENERATOR BRUSHES WEAR
24-32-61-CHK-10005-001 CHECK OF BRUSHES WEAR
(BY MEANS OF GRADUATED
RULE)
24-32-61-CHK-10005-002 CHECK OF BRUSHES WEAR
(BY MEANS OF GRADUATED
RULE)
24-32-61-CHK-10006-001 CHECK OF BRUSHES WEAR
(BY MEANS OF BRUSH GAUGE
P/N P611845)
24-32-61-CHK-10006-002 CHECK OF BRUSHES WEAR
(BY MEANS OF BRUSH GAUGE
P/N P611845)
24-32-61-RAI-10000-001 DC STARTER/GENERATOR 1/2
REMOVAL AND INSTALLATION
24-32-61-RAI-10000-002 DC STARTER/GENERATOR 1/2
REMOVAL AND INSTALLATION
24-32-61-RAI-10010-001 REMOVAL/INSTALLATION OF
STARTER GENERATOR
BRUSHES
24-32-61-RAI-10010-002 REMOVAL/INSTALLATION OF
STARTER GENERATOR
BRUSHES
24-32-81-OPT-10000-001 DC GEN CONTROL UNIT
OPERATIONAL TEST
24-32-81-RAI-10000-002 DC GEN CONTROL UNIT
REMOVAL AND INSTALLATION
24-32-83-RAI-10000-001 DC GEN CONTACTOR
REMOVAL AND INSTALLATION
24-32-87-RAI-10000-001 REMOVAL AND INSTALLATION
OF FEEDER OVHT SENSORS

N
D
N
D
N
D
N
D
N

R
R

AH

3
MAR/15

PAGE

1 TO

3 MAR/14

ALL

1 TO

12 DEC/14

51 TO

62

1 TO

14 DEC/14

63 TO

65

1 TO

7 DEC/14

51 TO

62

1 TO

9 DEC/14

63 TO

65

1 TO

4 DEC/14

ALL

1 TO

4 MAR/13

ALL

1 TO

5 APR/05

ALL

1 TO

7 DEC/14

51 TO

62

1 TO

7 DEC/14

63 TO

65

1 TO

8 DEC/14

51 TO

62

1 TO

8 DEC/14

63 TO

65

1 TO

8 DEC/14

51 TO

62

1 TO

9 DEC/14

63 TO

65

1 TO

6 DEC/14

51 TO

62

1 TO

6 DEC/14

63 TO

65

1 TO

4 DEC/14

ALL

1 TO

4 MAR/13

ALL

REVISION NO 12 - MAR/15

24-40-00-CHK-10000-001 CHECK OF CIRCUIT


BREAKERS
24-40-00-EAD-10000-003 DC AND AC EXTERNAL POWER
SUPPLY
24-40-00-EAD-10000-004 DC AND AC EXTERNAL POWER
SUPPLY
24-41-00-EAD-10000-003 AC WILD FREQUENCY
EXTERNAL POWER SUPPLY
24-41-00-EAD-10000-004 AC WILD FREQUENCY
EXTERNAL POWER SUPPLY
24-41-11-RAI-10000-001 REMOVAL AND INSTALLATION
OF AC GROUND POWER
RECEPTACLE 1XG
24-41-83-OPT-10000-001 ACW BUS POWER CONTROL
UNIT OPERATIONAL TEST
24-41-83-RAI-10000-001 ACW BUS POWER CONTROL
UNIT REMOVAL AND
INSTALLATION
24-42-00-EAD-10000-003 ACW SERVICE BUS EXTERNAL
POWER SUPPLY
24-42-00-EAD-10000-004 ACW SERVICE BUS EXTERNAL
POWER SUPPLY
24-42-00-OPT-10000-001 ACW SERVICE BUS TRANSFER
RELAYS OPERATIONAL TEST
24-42-00-OPT-10000-002 ACW SERVICE BUS TRANSFER
RELAYS OPERATIONAL TEST
24-46-00-EAD-10000-003 DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY
24-46-00-EAD-10000-004 DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY
24-46-00-PRO-10000-001 SHEDDING PROCEDURE TO
REDUCE ON GROUND THE DC
LOAD DEMAND
24-46-00-PRO-10000-002 SHEDDING PROCEDURE TO
REDUCE ON GROUND THE DC
LOAD DEMAND
24-46-11-RAI-10000-001 REMOVAL AND INSTALLATION
OF DC GROUND POWER
RECEPTACLE 1PG
24-46-83-OPT-10000-001 DC BUS POWER CONTROL
UNIT OPERATIONAL TEST

AH

4
MAR/15

PAGE

1 TO

6 APR/05

ALL

1 TO

7 MAR/15

ALL

1 TO

8 MAR/14

ALL

1 TO

4 DEC/14

51 TO

62

1 TO

5 DEC/14

63 TO

65

1 TO

5 APR/05

ALL

1 TO

5 DEC/14

51 TO

62

1 TO

6 DEC/14

63 TO

65

1 TO

5 APR/05

ALL

1 TO

6 DEC/14

1 TO

6 MAR/14

51 TO
59 TO
58 TO

REVISION NO 12 - MAR/15

24-46-83-RAI-10000-001 DC BUS POWER CONTROL


UNIT REMOVAL AND
INSTALLATION
R 24-46-84-RAI-10000-001 DC EXT PWR CONTACTOR
REMOVAL AND INSTALLATION
24-47-00-EAD-10000-003 DC SERVICE AND GROUND
HANDLING BUSES EXTERNAL
POWER SUPPLY
24-50-00-OPT-10000-001 OPERATIONAL TEST OF AC,
ACW AND DC NORMAL
DISTRIBUTION
24-50-00-OPT-10000-002 OPERATIONAL TEST OF AC,
ACW AND DC NORMAL
DISTRIBUTION
24-50-00-RAI-10000-001 REMOVAL AND INSTALLATION
OF NORMAL DISTRIBUTION
CIRCUIT RELAYS
24-65-00-OPT-10000-002 OPERATIONAL TEST OF STBY
OVERRIDE FUNCTION AND
ASSOCIATED INDICATING
24-65-00-OPT-10000-003 OPERATIONAL TEST OF STBY
OVERRIDE FUNCTION AND
ASSOCIATED INDICATING
24-65-81-RAI-10000-001 REMOVAL AND INSTALLATION
OF CONTACTORS 4PD AND
13PD
24-70-00-MSN-10000-002 BONDING INSPECTION
24-70-00-MSN-10000-003 BONDING INSPECTION

AH

57
65
58

5
MAR/15