Professional Documents
Culture Documents
ATTN: TECHNICAL
CC: OPERATION/SQE/PURCHASING/PERSONNEL
SUBJECT: INSPECTION/FAMILIARIZATION REPORT DURING ATTENDANCE AT M/V FORTUNE
GOOD DAY,
FOR YOUR GUIDANCE AND INFORMATION THE FOLLOWING JOBS CARRIED OUT DURING OUR
ATTENDANCE AT M/V FORTUNE FROM 03-13 NOVEMBER 2015 AT ARIAKE SHIPYARD, JAPAN.
A.CARRIED OUT INVENTORY OF SPARE PARTS, TOOLS ETC. AS PER LIST:
1.LIST OF SPARES, TOOLS AND OUTFITS (MACHNERY PART)- C/E & 2ND ENGR.
2.INVENTORY OF LIST OF ELECTRIC PART- ELEC.
3.LIST OF SPARE PARTS AND TOOL FOR ELECTRIC INSTALLATION ELEC.
4.LIST OF SPARES, TOOLS ETC (HULL PART)- BY MASTER & CH OFF.
5. SHIPS KEYS INVENTORY MASTER & CH OFF.
ALL ITEMS RECEIVED AS PER LIST.
B. ATTENDED DEMOSTRATION OF VARIOUS EQUIPMENT OPERATION BY SHIPYARD AND
MAKERS:
1. HATCH COVER NORMAL & EMCY OPERATION.
2. WINDLASS/MOORING OPERATION.
3. COMBINATION/PILOT LADDER.
4. ACCOMODATION LADDER.
5. BALLAST CONTROL OPERATION.
6. NAVIGATION LIGHTS.
7. FIRE ALARM & EXTINGUISHING SYSTEM.
8. STEERING GEAR NORMAL & EMCY OPERATION.
9. LIFEBOAT & RESCUE BOAT.
10. MAIN SWITCHBOARD & EMCY SWITCHBOARD.
11. C/HOLD WATER INGRESS SYSTEM.
12. ACCOM/ECR AIRCON & PROV REEFER OPERATION.
13. ENGINE WATER COOLING & BOILER WATER TREATMENT BY WILHELMSEN/UNITOR
REPRESENTATIVE.
14. BLUE BALLAST SYSTEM & WATER TREATMENT OPERATION.
15. D/G SYSTEM & OPERATION/EMCY GENERATOR OPERATION.
16. LOCAL FIRE FIGHTING SYSTEM.
17. ENGINE FOAM FIRE EXT SYSTEM/OPERATION.
18. EMCY FIRE PUMP.
19. SEWAGE SYSTEM.
20. WO INCINERATOR.
21. BOILER OPERATION.
22. FW GENERATOR OPERATION.
23. FO/LO PURIFIERS.
24. FO VISCOSITY CONTROL SYSTEM.
25. M/E REMOTE CONTROL OPERATION & EMCY OPERATION BY MAKER.
26. M/E, D/G & BOILER FO CHANGOVER PROCEDURE.
27. LOADICATOR OPERATION (MASTER & CH OFFICER).
28. VARIOUS BRIDGE EQUIPMENT FAMILIARIZATION (MASTER & CH OFFICER).
29. ELEVATOR OPERATION.
C. INITIAL BUNKER SURVEY 12/11/15 BY C/E:
TRIM=3.12
FO: T=22C/D=0.9634
FOT NO 1P = NIL.
INVENTORY OF LUBRICANTS:
NO 1 CYL OIL STOR TK (HSCO) = 9,000 LTRS.
NO 2 CYL OIL STOR TK (LSCO) = NIL.
ENGINE OIL STOR TK = 9,800 LTRS.
GENERATOR OIL STOR TK = 1,800 LTRS.
M/E LO SETT TK = NIL.
G/E LO SETT TK = NIL.
M/E SUMP TANK =20.00 M3 (MAIN LO PUMP NOT RUNNING).
G.
1.
2.
3.
4.
INVENTORY OF CHEMICALS:
SODIUM THIOSULFATE = 750 KGS (IN BAG 25KGS).
SODA ASH = 25 KGS (IN BAG).
FOAM SERV TANK = 2,100 LTRS.
NETRALIZER SERV TANK = 3,080 LTRS.
208L).
208L).
208L).
200L).
OBSERVATION:
AUX BOILER NO FO FLOWMETER.
PURIFIER CLEANING/MAINTENANCE TABLE NIL.
M/E AIR COOLER AIR SIDE CLEANING EQUIPMENT NIL.
EXH GAS ECO NO BLOW SOOT.
SOME SPARE PARTS/TOOLS NEED TO FIX FOR PROPER STORAGE.
ATTENDED BY:
1.MASTER R. BOLASOC.
2.C/O R. PASTRANA.
3.C/E T. SALIGAN.
4.2/E J. TUMAMAO.
5. ELEC M. MAHINAY.
BRGDS/MV FORTUNE