TABLE I
THREAD SIZE OF CONDUIT
Inches (NPT)
Explosionproof
38 inch
1-2
716 inch
2-5
58 inch
TABLE II
1 516
1 716
1 916
1 78
2 18
2 38
2 1116
2 1516
3 78
1 78
1 78
2 116
2 78
3 78
4 78
TABLE III
SIZE
EXPLOSIONPROOF
XCE/XJF Enclosures
m16
3 58
3 38
2 58
2 38
1 78
1 58
m20
3 18
2 18
1 78
1 m25
4 78
3 58
2 58
2 38
1 m32
5 18
4 18
3 78
3 18
2 78
2 38
1 m40
3 58
2 58
2 m50
4 58
3 78
3 58
4 78
4 58
3 78
4 58
2 m63
3 m75
5 38
5 58
5 78
NOTES 1. This information is compiled from data which we believe is reliable and is given in good faith. Since the methods of application and
conditions under which our products are used are beyond our control, we are not able to guarantee the application and/or use of
same. The user assumes all risks and liability in connection with the application and use of our products.
2. Dimensions are in inches.
3. Metric threads available from factory for most applications Consult Factory.
4. Consult Factory for special spacing arrangements. Hydro test may be required.
220
211
The ADALET Engineering Department is Available to Assist you in the Selection of Enclosures and Accessories.
EXPLOSIONPROOF ENCLOSURES
A minimum of (5) thread engagement, class 2 fit, required for group C & D applications.
A minimum of (7) thread engagement, class 2 fit, required for group B applications.
2.
Table I shows minimum box wall thickness for Auxiliary Device threads.
TABLE I
REQUIRED MINIMUM BOX WALL THICKNESS
Thread Size (In.) Group C & D min. (5) thread engagement Group B min. (7) thread engagement
Drill Dia.
-14 NPSM
38 Inch
Inch
.747/.759
-14 NPSM
38 Inch
Inch
.958/.970
1 -11 NPSM
716 Inch
58 Inch
1.201/1.211
38 - 18 NPSM
932 Inch
1332 Inch
.603/.612
38 16 UNC
516 Inch
716 Inch
516
3.
If Auxiliary Device contains undercut in engaging threaded section, the minimum wall
thickness shown in Table I must increase to maintain the minimum required thread
engagement. (Fig. A)
(continued next page)
EXPLOSIONPROOF
Auxiliary
Device
COUNTERSINK/
CHAMFER DEPTH
WALL
THICKNESS
TE L 216.267.9000
FAX 216.267.1681
info@adalet.com
221
212
XCE/XJF Enclosures
FIG. A
SEE NOTE 3
EXPLOSIONPROOF ENCLOSURES
4.
Table II provides the minimum distance an Auxiliary Device center can be placed from inside corner or back of box.
TABLE II
38 - 16 UNC
38 NPSM
NPSM
NPSM
1 NPSM
1 58
1 78
5.
Table III shows minimum spacing between conduit and Auxiliary Device entrances.
TABLE III
AUXILIARY DEVICE THREAD (In.)
3-
2-
1-
1-
3 58
3 38
2 58
2 38
1 78
1 58
4 58
3 18
2 18
1 78
3 58
2 78
2 58
2 38
2 18
1 78
3 78
2 38
2 18
38
6.
7.
Double all distances in Table III and IV for holes located in back wall.
Inside
Inside
Depth
Width
TABLE IV
TOP
Developed view of
box with sides laid
outward.
38
38
LEFT
Inside Length
EXPLOSIONPROOF
XCE/XJF Enclosures
Table III
BACK
LEFT
RIGHT
BOT.
Typical conduit
layout using
Table II & III.
Table II
222
213
The
The ADALET
ADALET Engineering
Engineering Department
Department is
is Available
Available to
to Assist
Assist you
you in
in the
the Selection
Selection of
of Enclosures
Enclosures and
and Accessories.
Accessories.