You are on page 1of 1

07 SHEET OF 23

BUILDING AND CONSTRUCTION AUTHORITY


APPROVED UNDER SECTION 6 OF THE
BUILDING CONTROL ACT (CHAPTER 29)
Project Ref. No: A053-031-1999

B
A

8400

8400

8400

8400

8400

3950

2165

250

115

For Commissioner Of Building Control

8400

8400

8400

9000
6220

2700

250

150

2700

8400

RECORD OF DRAWINGS
APPROVED BY BCA
ON 08 NOVEMBER 2002

26400

3000
2500

700

3000

9000
350

250

2650

700

9000

2550

2600

150

350

4985

8400
115

885

115

2200

350

3370

115

600

3850

115

350

ALUM. CLADDING
350

250

ALUM. CLADDING

8400

BOUNDARY LINE

9000
4200

8400

26400
8400
250

HR

UP

1475

DN
R=175
T=275

DN

FAP

UP

ELECT.
DUCT

LOBBY

MALE
W.C.

VOID
A.H.U.

FEMALE
W.C.

HT
RISER

HR

ELEC.
DUCT

TAS

300

600

1625

LOBBY

FIRE/
SERVICE
LIFT 2

6500

TAS
ELEC.
DUCT

ALUM. CLADDING

2750

VOID

FIRE/
SERVICE
LIFT 1

1375

A.H.U.

STAIR B

550

ELECT.
DUCT

1575

MALE
W.C.

2750

FEMALE
W.C.

6500

STAIR A

GLAZING AS SPECIFIC

8400

FAP

GLAZING AS SPECIFIC

WID

OFFICE

8400

OR

OFFICE

1.5M

ID

RR

E CO

E CO

RR

ID

WID

OR

1.5M

OFFICE

OFFICE

3
GRAZING AS SPECIFIC

OFFICE

8400

GRAZING AS SPECIFIC

OFFICE
4
CORRIDOR LINE FOR 6TH,7TH,8TH
9TH & 10TH STOREY ONLY

FAP

8400

LOBBY

OWNER'S SIGNATURE :

550

PE 3

PE 5

PE 7

PE 6

PE 8

PE 9

PE 11

PE 10

PE 12

PE 13

VOID

LOBBY

VOID

ADDRESS :

HONG LEONG PROPERTIES PTE LTD


36 ROBINSON ROAD #20-01
CITY HOUSE

PE 14
2300

PE 4

4200

UP

6500

DN

DRAWING TITLE :

350

STAIR C

2425

150

2925

2250

150

2655

7455

150

2250

350

2250

150

2655

150

2250

350

350

7455

350

2250

150

2655

150

2310

7515

350

6TH TO 14TH STOREY PLAN

8400

350

ALUM. CLADDING

350

26400

PROJECT TITLE :

PROPOSED RECLADDING WORKS TO


THE EXISTING 38 STOREY IBM TOWERS
ON LOT 595 TS 03 AT 80 ANSON
ROAD

ARCHITECTS :

"I, Goh Peng Thong hereby certify, subject to any waiver/


modification granted under Section 14 of the Act, that the
preparation of these building plans and the building works
shown on these plans are strictly in accordance with the
provisions of the Building Control Act (Cap 29) and the
Regulations made thereunder".

BOUNDARY LINE

GOH PENG THONG


B.Arch (S'pore) M.S.I.A.
Director

"I have inspected the building and investigated its overall


structure and that, in my opinion, the building is capable
of resisting the forces and moments which may be
increased or altered by reason of the repairs, alterations
or additions shown on these plans".

6TH TO 14TH STOREY PLAN


SCALE :-

1 : 200

ALFRED WONG PARTNERSHIP


PTE LTD
AWP
CHARTERED
ARCHITECTS
#12-02/04 PENINSULA PLAZA 111 NORTH BRIDGE ROAD (179098)
STAGE :

CONSULTANT REF NO. :

SCALE 1:200

10

15

20 METRES

SCALE :

PROJ. ARCH. : KCK

DATE : NOV 2001

DRAWING NO.

REV:

00

DC1

99AWP1

DRAWN :JP/JAMIE

1 : 200

CHECKED :

99AWP1/BP/606

APPROVED :
GPT

KCK/PO

DIGITAL FILE NO
J1606BP00

COPYRIGHT BY ALFRED WONG PARTNERSHIP PTE LTD . THIS DRAWING IS


THE PROPERTY OF ALFRED WONG PARTNERSHIP PTE LTD AND CANNOT BE
COPIED REPRODUCED PARTLY OR WHOLLY WITHOUT THE WRITTEN
PERMISSION OF ALFRED WONG PARTNERSHIP PTE LTD.