Date: 06.09.2016
Operator:
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Table of contents
SCI ROW 60
Project Cover
Table of contents
Luminaire parts list
PHILIPS BGP323 T35 1xECO209-3S/830 DW
Luminaire Data Sheet
Street 1
Planning data
Luminaire parts list
Photometric Results
3D Rendering
False Color Rendering
Valuation Fields
Valuation Field Roadway 1
Results overview
Observer
Observer 1
Isolines (L)
Observer 2
Isolines (L)
Observer 3
Isolines (L)
Observer 4
Isolines (L)
Valuation Field Sidewalk 1
Results overview
Valuation Field Sidewalk 2
Results overview
Valuation Field Roadway 2
Results overview
Observer
Observer 5
Isolines (L)
Observer 6
Isolines (L)
Observer 7
Isolines (L)
Observer 8
Isolines (L)
1
2
3
4
5
7
8
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Page 2
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Page 3
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Page 4
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
(Width: 6.000 m)
(Width: 3.500 m)
Roadway 2
Median 1
Roadway 1
Grass Strip 1
Sidewalk 1
(Width: 6.000 m)
Luminaire:
Luminous flux (Luminaire):
Luminous flux (Lamps):
Luminaire Wattage:
Arrangement:
Pole Distance:
Mounting Height (1):
Height:
Overhang (2):
Boom Angle (3):
Boom Length (4):
Page 5
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Luminaire:
Luminous flux (Luminaire):
Luminous flux (Lamps):
Luminaire Wattage:
Arrangement:
Pole Distance:
Mounting Height (1):
Height:
Overhang (2):
Boom Angle (3):
Boom Length (4):
Page 6
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Page 7
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Scale 1:557
Lav [cd/m]
1.10
1.50
U0
0.61
0.40
Ul
0.88
0.70
TI [%]
8
10
SR
0.91
0.50
Page 8
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:
Emin [lx]
2.86
0.60
Notice: To provide for uniformity, the actual value of the maintained average illuminance may not exceed
1.5 times the minimum value indicated for the class.
Emin [lx]
2.86
0.60
Notice: To provide for uniformity, the actual value of the maintained average illuminance may not exceed
1.5 times the minimum value indicated for the class.
Lav [cd/m]
1.10
1.50
U0
0.61
0.40
Ul
0.88
0.70
TI [%]
8
10
SR
0.91
0.50
Page 9
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Street 1 / 3D Rendering
Page 10
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Page 11
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Scale 1:557
Grid: 14 x 12 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME2
(Not all lighting performance requirements are met.)
Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:
Lav [cd/m]
1.10
1.50
U0
0.61
0.40
Ul
0.88
0.70
TI [%]
8
10
SR
0.91
0.50
Observer
Position [m]
Observer 1
Observer 2
Observer 3
Observer 4
Lav [cd/m]
U0
Ul
TI [%]
1.16
1.15
1.13
1.10
0.77
0.70
0.65
0.61
0.93
0.91
0.90
0.88
6
7
7
8
Page 12
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Lav [cd/m]
1.16
U0
0.77
Ul
0.93
TI [%]
6
1.50
0.40
0.70
10
Fulfilled/Not fulfilled:
Page 13
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Lav [cd/m]
1.15
U0
0.70
Ul
0.91
TI [%]
7
1.50
0.40
0.70
10
Fulfilled/Not fulfilled:
Page 14
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Lav [cd/m]
1.13
U0
0.65
Ul
0.90
TI [%]
7
1.50
0.40
0.70
10
Fulfilled/Not fulfilled:
Page 15
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Lav [cd/m]
1.10
U0
0.61
Ul
0.88
TI [%]
8
1.50
0.40
0.70
10
Fulfilled/Not fulfilled:
Page 16
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Scale 1:557
Grid: 14 x 4 Points
Accompanying Street Elements: Sidewalk 1.
Selected Lighting Class: S5
(Not all lighting performance requirements are met.)
Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:
1
Eav [lx]
5.45
3.00
Emin [lx]
2.86
0.60
Notice: To provide for uniformity, the actual value of the maintained average illuminance may not exceed 1.5 times the minimum value indicated for the class.
Page 17
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Scale 1:557
Emin [lx]
2.86
0.60
Notice: To provide for uniformity, the actual value of the maintained average illuminance may not exceed 1.5 times the minimum value indicated for the class.
Page 18
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Scale 1:557
Grid: 14 x 12 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME2
(Not all lighting performance requirements are met.)
Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:
Lav [cd/m]
1.10
1.50
U0
0.61
0.40
Ul
0.88
0.70
TI [%]
8
10
SR
0.91
0.50
Observer
Position [m]
Observer 5
Observer 6
Observer 7
Observer 8
Lav [cd/m]
U0
Ul
TI [%]
1.10
1.13
1.15
1.16
0.61
0.65
0.70
0.77
0.88
0.90
0.91
0.93
8
7
7
6
Page 19
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Lav [cd/m]
1.10
U0
0.61
Ul
0.88
TI [%]
8
1.50
0.40
0.70
10
Fulfilled/Not fulfilled:
Page 20
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Lav [cd/m]
1.13
U0
0.65
Ul
0.90
TI [%]
7
1.50
0.40
0.70
10
Fulfilled/Not fulfilled:
Page 21
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Lav [cd/m]
1.15
U0
0.70
Ul
0.91
TI [%]
7
1.50
0.40
0.70
10
Fulfilled/Not fulfilled:
Page 22
SCI ROW 60
06.09.2016
Operator
Telephone
Fax
e-Mail
Lav [cd/m]
1.16
U0
0.77
Ul
0.93
TI [%]
6
1.50
0.40
0.70
10
Fulfilled/Not fulfilled:
Page 23