Professional Documents
Culture Documents
Section-5.2
5.2.4
9
Electrical
10
10
Instrumentation
11
5.2.4.2
(D)
(E)
12
Electrical works
Surveillance
Section-5.5
5.5.2.4
(G)
Weather station
(H)
(C)
29
Switch room
(D)
Ventilation
(E)
Delivery system
(F)
Logic control
Onward transmission of Data
Alarms
5.5.2.5
5.5.3.4
(B)
32
(C)
33
(E)
34
General Utilities
(A)
38
General stipulations
(B)
41
(D)
43
(F)
46
Parshall flume
(H)
47
(J)
48
(L)
49
Chlorine tonners
(M)
49
(P)
(Q)
(S)
5.5.3.5
56
(B)
62
(C)
62
84/85 Illumination
86
91
5.5.3.7
(A)
93
94
General mechanical equipement
95
96
100
101
Exhaust fan
105
106
107
108
111
116
118
118
121
122
Sludge thickener
Sludge dewatering units
Variable speed drive
122
123
Pumps
Horizontal centrifugal pumps
125
133
Emergency lamps
133
Exhaust fan
5.5.3.8
(A)
135
Laboratory equipment
143
143
144
145
Design criteria for Electrical equipment
Protections
33KV switchboard
LV switchboard
Motors
146
Metering
33KV switchboard
LV incomer
LV outgoing
Indicating lamps
Voltage drop
147
Illumination level
Earthing
System description
Electrical system
148
Power transformer
150
152
154
170
171
172
173
HV indoor switchboard
Motors
174
175
176
176
HV and LV cables
177
178
LV Indoor switchboard
179
Circuit breaker
180
181
182
Bus bars
MCCB
MCB
Contactors and starters
DC equipment
110V battery
184
Battery charger
185
186
187
Lighting system
188
Lighting panels
Lighting fixtures and its accessories
190
191
192
194
195
196
197
5.5.3.9
(A)
(F)
198
Cables in trays
Cable pulling
Conduits / Pipes
Junction boxes / marshalling boxes
Fire proof sealing system
Fire stop/seal
Earthing and lightning protection system
201
202
202
202
Instrumentation specifications
General
Submission by contractor
Functional Design Specification
204
206
207
208
(H)
Type of Instrumentation
Online instruments
Ultrasonic flow - open channel
209
210
211
212
213
Electromagnetic flowmeter
Level Measuring system
Ultrasonic level meters
Ultrasonic differntial level
Pressure measuring system
214
215
216
pH analyzer
Residual chlorine measuring system
(I)
(J)
(K)
217
218
219
220
Laboratory instruments
221
Panels - Major
223
Panels - Minor
Panels - Composite
224
225
Panel isolation
225
226
228
229
Panel lighting
Panel ventilation
Panel piping and tubing
Panel labels
230
Panel finish
231
232
233
(L)
SCADA system
General
Sub-system description
236
UPS
239
242
IP camera
Video projection system
243
244
Moduler architecture
Controller packaging
Moduler hardware
Module racks
Power supply
Enclosures
245
Control module
Hardware
Software
Input / Output devices
246
5.6
10
(G)
18
Accessories
(H)
19
Surveillance cameras
In STP and SPS campus
19
19
21
21
23
23
24
5.6.4.13
29
38
40
41
41
43
44
Tender specification
entation
Level measurement
Temperature scanner for motor winding and bearing temperature and pump bearing for ea
Portable temperature measurement for motor & pump
pressure transmitter in clear water pumping main
pressure gauge at discharge of each pump
flow switch and sight flow glass for monitoring flow in each pump
full bore electromagnetic flow meters on pumped sewage. One flow meter at each STP. Ro
Control panel shall be provided at STP control along with battery and battery charger for fl
portable sound level meter
portable vibration meter
PLC based control panel for clear water pumping.
Local PC based SCADA.
Battery & battery charger for I&C system.
can be located over the sump or seperately. Land is expensive. Switch room will have
Power distribution panel, pump panels and automation/instrumentation panel.
Room to be properly illuminated & ventilated.
illumination inside the pumping station and outside also.
Pump sump with separate ventilation system. Sized to provide 10 air changes per hour.
matching inside temperature to outside, shall be automatic.
positive pressurized. Filtered to remove particulates inside pumping station.
low level and high level alarms to be generated in SPS and STP.
ical equipment for pumping station
Electromagnetic flow on common header.
Electricaly operated sluice gate
one DG set of full design load capacity
al, Instrumentation and Automation
Check general specifications.
Utilities
Outdoor lighting
Electric sub-station and distribution of power supply. Street and yard lighting. Fire hydrant
telephone and other modern means of communication for pump house for Main sub-statio
building, store, etc.
stipulations
by pass shall be provided around all flow meters and other in line instruments.
PLC based automatic feedback flow control using inline flow measurement and modulated
actuator.
all gas flow distribution shall be using PLC based automatic feedback flow control using in
modulated flow control valves with electric actuators.
all electrical equipment installed open in the sky shall be located above the high flood leve
and fine screens
Screen shall be Electrically operated with manual override.
decanter mechanism with local control box with manual operation selection and function b
trative building
Copy, email, fax, print, scan multipurpose machine - 1No.
2 desktop with required operating software
two UPS of size as directed by employer
Internet connection
split A.C. of 2tons each - 6Nos.
Power back-up
nd pipe trenches
Cable trenches are required.
witchboard
IDMT over current and earth fault for incomer
IDMT and instantaneous over current and earth fault protection for outgoing transformer f
Over current, short circuit and earth fault protection on ACBs/MCCBs
Thermal overload in all three phases to to trip with Single phase preventer.
Alternatively, microprocessor based relays shall also be used.
For 90KW and above Thermal, locked rotor, short circuit, negative sequence, under voltag
each motor.
witchboard
Incomer - Multifunction meter containing Ammeter, voltmeter, kw meter, frequency meter
meter, kva meter
Out going - Ammeter with selector switch
Ammeter with selector switch, Voltmeter with selector switch, kw meter, power factor met
datasheet
float cum boost type SCR connected in full wave bridge circuit.
harmonics in charger output shall not exceed 5%.
C distribution board (DB)
Each drive must have a soft starting feature and a bypasss arrangement for DOL starting
All drives shall be suitable for data connectivity with PLC/SCADA system and shall have su
protocol.
150% overload capacity for 60seconds
Total harmonic distortion shall comply with the provisions of IEEE519.
datasheet
Emergency lighting shall be dervied from 110VDC DB. Locations pump house, switch boar
10% of the total normal lighting shall be emergency type.
system installation
s / Pipes
boxes / marshalling boxes
of sealing system
standby power backup for 100% load. DG set upt to 1000KVA to supplied with acoustic en
entation specifications
sion by contractor
nal Design Specification
Details
gs and schedule
requirement for Instrumentation and Control system
ent design citeria
entation system shall be provided to monitor the following parameters
Online DO
Ultrasonic level
Ultrasonic differntial level
Ultrasonic open channel flow
Pressure transmitter
Online TSS
Online Residual chlorine measuring system
Indicative BOD analyzer
Electromagnetic flowmeter
Instrumentation
nstruments
nic flow - open channel
suitable for installation in H2S atmosphere
Datasheet
magnetic flowmeter
Datasheet
easuring system
nic level meters
Datasheet
nic differntial level
Datasheet
e measuring system
Datasheet
ed oxygen measuring system - DO analyzer
Datasheet
spended solids measuring system - TSS analyser
Datasheet
Datasheet
l chlorine measuring system
Datasheet
ve BOD analyzer
Datasheet
ory instruments
List of laboratory instruments
rotection devices
s for field instruments
Details
esign and construction
Details
Details
Details
Composite
Details
Glass reinforced plastic (GRP)
Details
otection
Details
Details
rminal blocks
Details
ternal wiring
Details
iring identification and termination
Details
Details
Details
Details
entilation
Details
ping and tubing
Details
Details
Details
al indicators and integrators
Details
Details
ype alarm annunciators
Details
ttons and indicator lights
Details
e signal transmission
Details
e process controllers
Details
Details
Redundant communication through fibre cable (read)
tem description
l integrated controller
It shall have an integrated redundant interface for the IO modules as well as redundant int
Should be able to communicate to its redundant pair directly preferably on a passive back
architecture
er packaging
hardware
Output devices
Each module shall have its own microprocessor to execute its input/output function
max 8 channels for analog and 16 channels for digital
rmination for IO modules
communication
the communication system shall provide redundant, high speed, secure controller informa
communication bus
anagement software
Remark
If 33KV single circuit is considered how 2-Incomer and 1-bus coupler is applicable.
As no HT motors are envisaged, 33/3.45KV transformer is not required.
Now 33/0.433KV transformer will be required
Not
Not
Not
Not
applicable
applicable
applicable
applicable
as
as
as
as
Clarify
2Nos. UPS?
Power back-up
How?
Mechanical or transmitter?
TPL to confirm.
TPL to confirm.