You are on page 1of 117

BSC6900 GSM

Data Configuration

www.huawei.com

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.

Learning Guide


Before learn this course, you should have:




Learned BSC6900 Hardware System Structure

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page1

References


BSC6900 Commissioning Guide

BSC6900 Initial Configuration Guide

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page2

Objectives


Upon completion of this course, you will be able to:




Detail the Procedure of BSC6900 Data Configuration

Perform Global Data Configuration

Perform Equipment Data Configuration

Perform Interface Configuration

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page3

Contents
1. Data Configuration Overview
2. Preparation
3. Configuring the Global Information
4. Configuring the Equipment Data
5. Configuring the Interfaces

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page4

Data Configuration Overview




Configuration Tools


Web LMT (Local Maintenance Terminal)




CME (Configuration Management Express)




Based on MML (Man Machine Language)

Based on GUI (Graphic User Interface)

LMT Execution Modes




Batch mode


multiple MML commands in a script

Single Command Mode




one command at a time and carry it out directly

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page5

Data Configuration Procedure


Preparation

Configuring the Global


Information

Configuring the Equipment Data

Configuring the Interfaces

LOAD

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page6

Contents
1. Data Configuration Overview
2. Preparation
3. Configuring the Global Information
4. Configuring the Equipment Data
5. Configuring the Interfaces

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page7

Preparation


Data Configuration Right Management




Forcibly Obtain CM Control Right (FOC CMCTRL)

Request the CMC right (REQ CMCTRL)

BSC6900 controls whether LMT or M2000 has the permission


to configure the data at a moment to avoid the data conflict


Set CM Control enable switch (SET CMCTRLSW)

Check the status of CMC (LST CMCTRL)

Lock the CMC right (LCK CMCTRL)

Unlock the CMC right (ULK CMCTRL)

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page8

Preparation


Data Configuration Mode




Set Offline State (SET CFGDATAINEFFECTIVE)

Set Online State (SET CFGDATAEFFECTIVE)

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page9

Preparation


Data Initialization (RST DATA)




RST DATA will remove all configuration data in BAM

Data in BAM
(OMUa)

RST DATA
Data in FAM
(Other Boards)

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page10

Contents
Preparation

1. Data Configuration Overview


2. Preparation
3. Configuring the Global Information
4. Configuring the Equipment Data
5. Configuring the Interfaces

Configuring the Global


Information

Configuring the Equipment Data

Configuring the Interfaces

LOAD

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page11

Basic Data

OPC

DPC

M3UA Entities

Global Data configuration




Configuring the Basic Data

Configuring the OPC (Original Signaling Point Code)

Configuring the DPC (Destination Signaling Point Code)

Configuring the M3UA Local and Destination Entities




This section describes how to configure the local and


destination M3UA entities. You need to configure the M3UA
entities when the IP-based networking is used.

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page12

Basic Data

OPC

DPC

M3UA Entities

Configuring the Basic Data




Add GSM BSC Basic Information (SET BSCBASIC)




Area Code: Local area code, for example, 021 for Shanghai.

CC: Country code, for example, 86 for China

Interface Tag : Phase tag for GSM protocols supported by the A,


Um, Abis interface

Support TFO Codec Optimize: Whether to enable the tandem free


operation (TFO) Codec optimizing function

Support High Frequency Band : DCS1800, PCS1900

Service Mode: Service mode of the BSC6900, Actual Value Range:


SEPARATE, TOGETHER

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page13

Basic Data

OPC

DPC

M3UA Entities

Configuring the Basic Data




Add GSM Operator (ADD GCNOPERATOR)




Operator Type: Primary operator or secondary operator




Each BSC6900 must be configured with one and only one primary
operator. In the case of RAN Sharing, a maximum of fifteen
secondary operators can be configured.

Actual Value Range: PRIM, SEC

Operator Index

Operator Name

MCC: Mobile Country Code

MNC: Mobile Network Code

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page14

Basic Data

OPC

DPC

M3UA Entities

Configuring the OPC




Add OSP (Original Signaling Point) (ADD OPC)




OSP name

OSP index

Network ID: INT, INTB, NAT, NATB

OSP code bits:BIT14, BIT16, BIT24

Signal point data format:




WNF(Whole Number Format), DNF(Divided Number Format)

OSP code [Whole Number]




The OSP code cannot be 0. It is assigned in the SS7 signaling


network and each OSP code is unique

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page15

Basic Data

OPC

DPC

M3UA Entities

Configuring the DPC




Add DSP (ADD N7DPC)




DSP name

DSP index

OSP index

Signal point data format

DSP code [Whole Number]

DSP type

Signaling route mask: Signaling route load sharing.




In the value, the number of 1s (represented by n) determines the


maximum number (2) of routes for the load sharing.

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page16

Basic Data

OPC

DPC

M3UA Entities

Configuring the M3UA Local Entities




Add M3UA Local Entity (ADD M3LE)




Local entity No.

OSP index

Local entity type




M3UA_ASP, M3UA_IPSP

Local entity name

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page17

Basic Data

OPC

DPC

M3UA Entities

Application scenario of ASP and IPSP




ASP: A process instance of


an application server

BSC

Scenario 1 MSC Server


/SGSN

IPSP: A process instance


of an IP_based application

AS: Application Server

BSC

Scenario 2

(MSC server/SGSN)


SG: Signaling Gateway


(MGW)

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page18

MGW

Basic Data

OPC

DPC

M3UA Entities

Configuring the M3UA Destination Entities




Add M3UA Destination Entity (ADD M3DE)




Destination entity No.

Local entity No.

DSP index

Destination entity type




M3UA_SGP(M3UA SGP), M3UA_IPSP(M3UA IPSP),


M3UA_SS7SP(M3UA SS7SP), M3UA_SP(M3UA SP)

Destination entity name

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page19

Contents
Preparation

1. Data Configuration Overview


2. Preparation
3. Configuring the Global Information
4. Configuring the Equipment Data
5. Configuring the Interfaces

Configuring the Global


Information

Configuring the Equipment Data

Configuring the Interfaces

LOAD

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page20

System

Hardware

Clocks

Equipment Data Configuration




Configuring the System Information

Configuring a Cabinet

Configuring a Subrack

Configuring a Board

Configuring the Clocks

Configuring the Time

Configuring the IP Address of the EMS Server

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page21

EMS

System

Hardware

Clocks

EMS

Configuring the System Information




Set Base Station Controller System Information (SET SYS)


(Optional)


System description

NE Name

Contact mode of the manufacturer

System Location

System services

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page22

System

Hardware

Clocks

Configuring a Cabinet & Subrack




Add Cabinet (ADD CAB)




Use this command to add an EPR or TCR.

Cabinet No.

Is remote cabinet :Yes/No

Add Service Processing Subrack (ADD SUBRACK)




Subrack No.

Subrack name

Connect power monitoring board: Yes/No

Subrack Type: EPS, TCS

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page23

EMS

System

Hardware

Clocks

EMS

Open SCUa Ports




Open SCUa Ports (SET SCUPORT)




After a subrack is added, run this command to enable the


corresponding port on the SCU board in the main subrack.

Subrack No

Port No

Port Switch: Close, Open

If the SCUa ports are closed, the MAC switching couldnt be


implemented between subracks. So we should use this
command to open the SCUa ports

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page24

System

Hardware

Clocks

EMS

Configuring a Board


Add Board (ADD BRD)




This command can be used by all types of boards except the


SCUa, GCUa, and GCGa

Subrack No.

Board Class : INT, DPU, XPU, OMU, SAU, TNU

Board Type

Slot No.

Backup: Whether to configure the backup board

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page25

System

Hardware

Clocks

EMS

Configuring a Board


Add Board (ADD BRD)




Logical Function Type: OAM, TDM_Switching, GCP, RGCP,


MCP, GTC, GPCU, IP, FR, HDLC, TDM, GbIP, Abis_TDM,
Ater_TDM, Pb_TDM, A_TDM, Abis_IP, SAU

TC board: Whether it is configured inside the TCS

MPU Subrack No.

MPU Slot No.

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page26

System

Hardware

Clocks

EMS

Configuring the Clocks




Set Board Clock Source (SET CLK)




Set the clock source data on the interface board in the MPS or EPS
subrack

Add Clock Source (ADD CLKSRC)




Set Clock Working Mode (SET CLKMODE)




BITS,8k,GPS,Line clock

Set the working modes of clock sources: manual /auto /free

Set Clock Board Type (SET CLKTYPE)




Set the type of a clock board: GCUa /GCGa

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page27

System

Hardware

Clocks

EMS

Configuring the Time




Set Information About Time Zone and Daylight Saving


Time (SET TZ)


Set the time zone and daylight saving time to ensure a


correct local time for the current system

Add SNTP Server for the Network Element (ADD


SNTPSRVINFO)


Add the information of the SNTP server connected to the


network element

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page28

System

Hardware

Clocks

EMS

Configuring the IP Address of the EMS Server




Add IP Address For EMS (Element Management System)


(ADD EMSIP)


EMS IP Address: IP address of the NE management system

Subnet Mask

OMU External Network Virtual IP

OMU External Network Mask

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page29

Contents
Preparation

1. Data Configuration Overview


2. Preparation
3. Configuring the Global Information
4. Configuring the Equipment Data
5. Configuring the Interfaces

Configuring the Global


Information

Configuring the Equipment Data

Configuring the Interfaces

LOAD

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page30

Contents


5. Interface Data Configuration




Ater Interface Data Configuration (over TDM)

A Interface Data Configuration (over IP)

A Interface Data Configuration (over TDM)

A Interface Data Configuration (over Transmission Resource


Pool)

Gb Interface Data Configuration (over IP)

Gb Interface Data Configuration (over FR)

Pb Interface Data Configuration (only Outer PCU need


configure)

Iur-g Interface Data Configuration (only interface between

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page31

BSSs or between a BSS and a RNS need configure)

Path

OML

Ater Connection Path


Configuration


Add Ater connection path (ADD ATERCONPATH)




Ater connection path index

BM subrack No.

BM slot No.

TC subrack No.

TC slot No.

TC port No.

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page32

SL

Path

OML

SL

Ater OML Configuration




Add Ater OML (ADD ATEROML) (Only for remote TCS)




Ater OML Index

Ater Connection Path Index: Select Ater connection path


that the OML is located at

Timeslot Mask : Select the timeslots configured for the OML

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page33

Path

OML

SL

Ater SL Configuration


Add Ater SL (ADD ATERCONSL) (Only for remote TCS)




Ater signaling Channel ID

Ater connection path index: Select Ater connection path


that the RSL is located at

Ater mask: Select the timeslot configured for the RSL

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page34

Contents


5. Interface Data Configuration




Ater Interface Data Configuration (over TDM)

A Interface Data Configuration (over IP)

A Interface Data Configuration (over TDM)

A Interface Data Configuration (over Transmission Resource


Pool)

Gb Interface Data Configuration (over IP)

Gb Interface Data Configuration (over FR)

Pb Interface Data Configuration (only Outer PCU need


configure)

Iur-g Interface Data Configuration (only interface between

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page35

BSSs or between a BSS and a RNS need configure)

Protocol stack of A Interface over


IP


Signaling plane adopts M3UA/SCTP/IP protocol stack.

User plane adopts RTP/UDP/IP protocol stack.


BSC A Interface MSC Server

BSC

A Interface

DTAP BSSMAP

DTAP BSSMAP

SCCP
M3UA
SCTP
IP
MAC/PPP

SCCP
M3UA
SCTP
IP
MAC/PPP

MSC

DTAP BSSMAP

DTAP BSSMAP

SCCP
MTP
Layer1

SCCP
MTP
Layer1
A over TDM

Signaling plane of A over IP


BSC A Interface
Voice
RTP
UDP
IP
MAC/PPP

MGW

Voice
RTP
UDP
IP
MAC/PPP

User plane of A over IP

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page36

IP over Ethernet networking


IP over Ethernet Networking (Layer 2)

IP over Ethernet Networking (Layer 3)

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page37

GCNNODE

PHY Layer

Data Link

Control plane

User Plane

Mapping

A Interface Data Configuration (Over IP)




Configuration Procedure


BSC

Configuring GSM CN
Node

Configuring Physical
Layer

Configuring Data Link

DPU

Layer


Configuring Control
Plane

Configuring the
Mapping Between
Service Types and

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Transmission Resources

Page38

GCNNODE

PHY Layer

Data Link

User Plane

Control plane

Mapping

GSM CN Node Configuration (Over IP)




Add GSM CN Node (ADD GCNNODE)




CN node index

DSP index

DPC group index: Index of a DPC group

Operator name

MSC ID

Bearer for A Interface User Plane: IP

Report BSS Transmission Capability: YES

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page39

GCNNODE

PHY Layer

Data Link

Control plane

User Plane

Mapping

Configuring the Physical Layer and Data Link Layer


for the FG2a/FG2c/FG2d/GOUa/GOUc/GOUd Board


Set attributes of the Ethernet port (SET ETHPORT)




Subrack No.

Slot No.

Board type

Port No.


0~7(FG2a), 0~1(GOUa), 0~11(FG2c), 0~3(GOUc)

Auto negotiation


ENABLE, DISABLE

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page40

GCNNODE

PHY Layer

Data Link

Control plane

User Plane

Mapping

Configuring the Physical Layer and Data Link


Layer for the
FG2a/FG2c/FG2d/GOUa/GOUc/GOUd Board


Add a standby Ethernet port (ADD ETHREDPORT)

(Optional)


Subrack No.

Main Board Logic slot No.

Port No.


0~7(FG2a), 0~1(GOUa), 0~11(FG2c), 0~3(GOUc)

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page41

GCNNODE

PHY Layer

Data Link

Control plane

User Plane

Mapping

Configuring the Physical Layer and Data Link


Layer for the
FG2a/FG2c/FG2d/GOUa/GOUc/GOUd
Board
 Add IP address of the Ethernet port (ADD ETHIP) ( in link
non-aggregation mode)


Subrack No.

Slot No.

Port No.

IP address index

Local IP address

Subnet mask

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page42

GCNNODE

PHY Layer

Data Link

Control plane

User Plane

Mapping

Configuring the Physical Layer and Data Link


Layer for the
FG2a/FG2c/FG2d/GOUa/GOUc/GOUd Board


Add a link aggregation group (ADD ETHTRK) ( in link

aggregation mode)


Subrack No.

Slot No.

Trunk No.: Aggregation group number

Aggregation mode


When this parameter is set to static aggregation, the LACP


protocol is activated; otherwise, the LACP protocol is deactivated.

Value Range: STATIC_LACP, MANUAL_AGGREGATION

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page43

GCNNODE

PHY Layer

Data Link

Control plane

User Plane

Mapping

Configuring the Physical Layer and Data Link


Layer for the
FG2a/FG2c/FG2d/GOUa/GOUc/GOUd
Board
 Add a link to the aggregation group (ADD ETHTRKLNK)
( in link aggregation mode)


Subrack No.

Slot No.

Trunk No.

Trunk Link Slot No.

Trunk Link No.

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page44

GCNNODE

PHY Layer

Data Link

Control plane

User Plane

Mapping

Configuring the Physical Layer and Data Link


Layer for the
FG2a/FG2c/FG2d/GOUa/GOUc/GOUd Board


Add the IP address of the link aggregation group (ADD

ETHTRKIP) ( in link aggregation mode)




Subrack No.

Slot No.

Trunk No.

IP address index

Local IP address

Subnet mask

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page45

GCNNODE

PHY Layer

Data Link

Control plane

User Plane

Mapping

Configuring the Physical Layer and Data Link


Layer for the
FG2a/FG2c/FG2d/GOUa/GOUc/GOUd Board


Add the device IP address of the board in case of layer 3


networking (ADD DEVIP) (Optional)


Subrack No.

Slot No.

Device IP address type: LOGIC_IP(Logical IP Address),


IPOA_CLIENT_IP(IPOA Client IP Address


Boards in IP transmission mode can be configured with the DEVIP only in


the type of "LOGIC_IP".
Boards in ATM transmission mode can be configured with the DEVIP only in
the type of "IPOA Client IP Address".

IP address

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page46

GCNNODE

PHY Layer

Data Link

Control plane

User Plane

A Interface Physical Layer and Data


Link Layer Configuration (Over IP)
Board

Physical layer

Data link layer

POU

SET E1T1
SET OPT
SET COPTLNK

ADD PPPLNK
or
ADD MPGRP ADD MPLNK

PEU

SET E1T1

ADD PPPLNK
or
ADD MPGRP ADD MPLNK

FG2

SET ETHPORT
ADD ETHIP/ADD DEVIP

ADD ETHTRK,
ADD ETHTRKLNK, ADD
ETHTRKIP

GOU

SET ETHPORT
ADD ETHIP/ADD DEVIP

ADD ETHTRK,
ADD ETHTRKLNK, ADD
ETHTRKIP

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page47

Mapping

GCNNODE

PHY Layer

Data Link

User Plane

Control plane

Mapping

Configuring the Control Plane of the A


Interface (over IP)


Add SCTP Signalling Link (ADD SCTPLNK)




Signalling link mode :Server/Client




Server mode: BSC6900 starts the listening and waits for the peer
to send the SCTP-INIT message.

Client mode: BSC6900 actively sends the SCTP-INIT message.

Application type :NBAP, M3UA, BBAP




The upper layer application type of A interface is M3UA.

Local/Destination SCTP port No.

First local/destination IP address

Second local/destination IP address

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page48

GCNNODE

PHY Layer

Data Link

Control plane

User Plane

Configuring the Control Plane of the A


Interface (over IP)


Add M3UA link set (ADD M3LKS)




Signalling link set index

Destination entity No.

M3UA signaling link name

Add an M3UA route (ADD M3RT)




Destination entity No

Signalling link set index

M3UA route name

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page49

Mapping

GCNNODE

PHY Layer

Data Link

Control plane

User Plane

Configuring the Control Plane of the A


Interface (over IP)


Add M3UA link (ADD M3LNK)




SCTP link No.

M3UA Signaling link name

Add an adjacent node (ADD ADJNODE)




Adjacent Node ID

Adjacent Node Name

Adjacent Node Type

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page50

Mapping

GCNNODE

PHY Layer

Data Link

Control plane

User Plane

Configuring the User Plane of the A


Interface (over IP)


Add an IP path (ADD IPPATH)




Adjacent Node ID

IP path ID

Interface Type

Forward Bandwidth

Backward Bandwidth

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page51

Mapping

GCNNODE

PHY Layer

Data Link

Control plane

User Plane

Mapping

Configuring the User Plane of the A


Interface (over IP)


Add an IP route (ADD IPRT) (Optional)




To add an IP route when the layer 3 networking mode is


used between the BSC6900 and the CS domain. To add
more IP routes, run this command repeatedly.

DSTIP: Destination IP address

DSTMASK: Destination address mask

NEXTHOP: Forward route address

PRIORITY: Priority

REMARK: Route use description

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page52

GCNNODE

PHY Layer

Data Link

User Plane

Control plane

Mapping

Configuring the User Plane of the A


Interface (over IP)


Set TC DSP Resource Type (SET TCTYPE)




The TC resource type can be set only when the


DPUb/DPUc/DPUf board is configured in the MPS/EPS subrack
and the logical function type is GTC.

DSP No.: Number of a DSP in the DPU board.




The number of a DSP in the DPUf board ranges from 0 to 47.

The number of a DSP in the DPUb/DPUc board ranges from 0 to 21.

The type of TC resource: GTC/UTC/ITC

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page53

GCNNODE

PHY Layer

Data Link

Control plane

User Plane

Mapping

Configuring the Mapping Between Service Types


and Transmission Resources for the Adjacent Node


Add Transport Resource Mapping (ADD TRMMAP)




Add Factor Table (ADD TRMFACTOR)




Add a transport resource mapping

Add an activation factor table

Add Node Mapping (ADD ADJMAP)




Add the TRM mapping to an adjacent node and to add the


mapping from interface transmission type to TRMMAP
index and factor index

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page54

Contents


5. Interface Data Configuration




Ater Interface Data Configuration (over TDM)

A Interface Data Configuration (over IP)

A Interface Data Configuration (over TDM)

A Interface Data Configuration (over Transmission Resource


Pool)

Gb Interface Data Configuration (over IP)

Gb Interface Data Configuration (over FR)

Pb Interface Data Configuration (only Outer PCU need


configure)

Iur-g Interface Data Configuration (only interface between

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page55

BSSs or between a BSS and a RNS need configure)

GCNNODE

E1/T1

MTP3LKS

MTP3LNK

MTP3RT

GSM CN Node Configuration (Over


TDM)


Add GSM CN Node (ADD GCNNODE)




CN node index

DSP index

DPC group index: Index of a DPC group




When multiple DPCs or one DPC serves as a logical entity, this


logical entity is called a DPC group. When the MSC pool function
is activated, the user plane resources on the A interface are
shared among the MSCs in the pool, and thus load balancing is
achieved

Operator name

MSC ID

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page56

GCNNODE

E1/T1

MTP3LKS

MTP3LNK

MTP3RT

A Interface E1T1 Configuration (Over TDM)




Add A interface E1/T1 (ADD AE1T1)




Subrack No.

Slot No.

Port No.

DPC group index

OPC index

Timeslot type: Set all timeslots to CIC or NULL

BSC flag: Main BSC or subsidiary BSC

Start CIC: The start CIC No. of the E1/T1

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page57

GCNNODE

E1/T1

MTP3LKS

MTP3LNK

MTP3RT

A MTP3 Link Set Configuration (Over


TDM)


Add MTP3 link set (ADD MTP3LKS)




Signaling link set index: To identify an signaling link set


uniquely

DSP index

Signaling link mask: Indicates link load sharing.




In the value, the number of 1s (represented by n) determines the


maximum number (2^n) of links for the load sharing.

Signaling link set name

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page58

GCNNODE

E1/T1

MTP3LKS

MTP3LNK

MTP3RT

A MTP3 Link Configuration (Over TDM)




Add MTP3 links (ADD MTP3LNK)




Signaling link set index

Signaling link code

Link bearer type




MTP2: indicates that the lower layer link bearer is the MTP2 used in TDM scenario

SAAL: indicates that the lower layer link bearer is the M3UA used in SAAL scenario

TC mode: To specify the mode of TC

MTP2 Link No.: the A interface E1 No. bearing this signaling link

A interface timeslot mask

Link Rate Type: 64kbps or 2Mbps

Signaling Link Name

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page59

GCNNODE

E1/T1

MTP3LKS

MTP3LNK

MTP3RT

A MTP3 Routing Configuration (Over


TDM)


Add MTP3 routing information (ADD MTP3RT)




DSP index

Signaling link set index: To identify an signaling link set


uniquely

Signaling route name

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page60

Contents


5. Interface Data Configuration




Ater Interface Data Configuration (over TDM)

A Interface Data Configuration (over IP)

A Interface Data Configuration (over TDM)

A Interface Data Configuration (over Transmission


Resource Pool)

Gb Interface Data Configuration (over IP)

Gb Interface Data Configuration (over FR)

Pb Interface Data Configuration (only Outer PCU need


configure)

Iur-g Interface Data Configuration (only interface between

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page61

BSSs or between a BSS and a RNS need configure)

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

GSM CN Node Configuration




Add GSM CN Node (ADD GCNNODE)




CN node index

DSP index

DPC group index: Index of a DPC group

Operator name

MSC ID

Bearer for A Interface User Plane: IP

Report BSS Transmission Capability: YES

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page62

User Plane

Mapping

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Mapping

Configuring the Physical Layer and Data Link Layer


for the FG2c/FG2d/GOUc/GOUd Board


Set attributes of the Ethernet port (SET ETHPORT)




Subrack No.

Slot No.

Board type

Port No.


0~7(FG2a), 0~1(GOUa), 0~11(FG2c), 0~3(GOUc)

Auto negotiation


ENABLE, DISABLE

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page63

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Mapping

Configuring the Physical Layer and Data Link Layer


for the FG2c/FG2d/GOUc/GOUd Board


Add a standby Ethernet port (ADD ETHREDPORT)


(Optional)


Subrack No.

Main Board Logic slot No.

Port No.


0~7(FG2a), 0~1(GOUa), 0~11(FG2c), 0~3(GOUc)

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page64

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Mapping

Configuring the Physical Layer and Data Link Layer


for the FG2c/FG2d/GOUc/GOUd Board


Add IP address of the Ethernet port (ADD ETHIP) ( in link


non-aggregation mode)


Subrack No.

Slot No.

Port No.

IP address index

Local IP address

Subnet mask

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page65

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Mapping

Configuring the Physical Layer and Data Link Layer


for the FG2c/FG2d/GOUc/GOUd Board


Add a link aggregation group (ADD ETHTRK) ( in link


aggregation mode)


Subrack No.

Slot No.

Trunk No.: Aggregation group number

Aggregation mode


When this parameter is set to static aggregation, the LACP


protocol is activated; otherwise, the LACP protocol is deactivated.

Value Range: STATIC_LACP, MANUAL_AGGREGATION

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page66

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Mapping

Configuring the Physical Layer and Data Link Layer


for the FG2c/FG2d/GOUc/GOUd Board


Add a link to the aggregation group (ADD ETHTRKLNK)


( in link aggregation mode)


Subrack No.

Slot No.

Trunk No.

Trunk Link Slot No.

Trunk Link No.

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page67

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Mapping

Configuring the Physical Layer and Data Link Layer


for the FG2c/FG2d/GOUc/GOUd Board


Add the IP address of the link aggregation group (ADD


ETHTRKIP) ( in link aggregation mode)


Subrack No.

Slot No.

Trunk No.

IP address index

Local IP address

Subnet mask

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page68

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Mapping

Configuring the Physical Layer and Data Link Layer


for the FG2c/FG2d/GOUc/GOUd Board


Add the the mapping between IP addresses and VLAN IDs


(ADD VANID) (in multiple VLAN gateways mode)


Subrack No.

Slot No.

Next Hop IP address

VLAN ID.

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page69

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Mapping

Configuring the Physical Layer and Data Link Layer


for the FG2c/FG2d/GOUc/GOUd Board


Add the device IP address of the board in case of layer 3


networking (ADD DEVIP)


Subrack No.

Slot No.

Device IP address type: LOGIC_IP(Logical IP Address),


IPOA_CLIENT_IP(IPOA Client IP Address


Boards in IP transmission mode can be configured with the DEVIP only in


the type of "LOGIC_IP".
Boards in ATM transmission mode can be configured with the DEVIP only in
the type of "IPOA Client IP Address".

IP address.

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page70

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Configuring the Transmission Resource Pool




Add a policy-based IP route based on the source IP


address(ADD SRCIPRT)


Subrack No.

Slot No.

IP TYPE.

Source IP address.

Forward route address.

Standby Next hop switch.

Standby next hop.

Purpose description.

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page71

Mapping

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Configuring the Transmission Resource Pool




Add a policy-based IP route based on the source IP


address(ADD SRCIPRT)


Subrack No.

Slot No.

IP TYPE.

Source IP address.

Forward route address.

Standby Next hop switch.

Standby next hop.

Purpose description.

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page72

Mapping

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Configuring the Transmission Resource Pool




Add the transmission resource pool(ADD IPPOOL)




Transmission Resource Pool Index

Transmission Resource Pool Name

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page73

Mapping

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Mapping

Configuring the Transmission Resource Pool




Add an IP address to the transmission resource pool


(ADD IPPOOLIP)


Transmission Resource Pool Index

Subrack No.

Slot No.

IP Address in Transmission Resource Pool

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page74

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Mapping

Configuring the Control Plane of the A Interface


(over Transmission Resource Pool)


Add SCTP Signalling Link (ADD SCTPLNK)




Signalling link mode :Server/Client




Server mode: BSC6900 starts the listening and waits for the peer
to send the SCTP-INIT message.

Client mode: BSC6900 actively sends the SCTP-INIT message.

Application type :NBAP, M3UA, BBAP




The upper layer application type of A interface is M3UA.

Local/Destination SCTP port No.

First local/destination IP address

Second local/destination IP address

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page75

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Mapping

Configuring the Control Plane of the A Interface


(over Transmission Resource Pool)


Add M3UA link set (ADD M3LKS)




Signalling link set index

Destination entity No.

M3UA signaling link name

Add an M3UA route (ADD M3RT)




Destination entity No

Signalling link set index

M3UA route name

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page76

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Mapping

Configuring the Control Plane of the A Interface


(over Transmission Resource Pool)


Add M3UA link (ADD M3LNK)




SCTP link No.

M3UA Signaling link name

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page77

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Configuring the User Plane of the A Interface


(over Transmission Resource Pool)


Add an adjacent node (ADD ADJNODE)




Adjacent Node ID

Adjacent Node Name

Adjacent Node Type

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page78

Mapping

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Mapping

Configuring the User Plane of the A Interface


(over Transmission Resource Pool)


Set TC DSP Resource Type (SET TCTYPE)




The TC resource type can be set only when the


DPUb/DPUc/DPUf board is configured in the MPS/EPS subrack
and the logical function type is GTC.

DSP No.: Number of a DSP in the DPU board.




The number of a DSP in the DPUf board ranges from 0 to 47.

The number of a DSP in the DPUb/DPUc board ranges from 0 to 21.

The type of TC resource: GTC/UTC/ITC

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page79

GCNNODE

PHY Layer

Data Link

Transmission
Resource Pool

Control plane

User Plane

Mapping

Configuring the Mapping Between Service Types


and Transmission Resources for the Adjacent Node


Add Transport Resource Mapping (ADD TRMMAP)




Add Factor Table (ADD TRMFACTOR)




Add a transport resource mapping

Add an activation factor table

Add Node Mapping (ADD ADJMAP)




Add the TRM mapping to an adjacent node and to add the


mapping from interface transmission type to TRMMAP
index and factor index

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page80

Contents


5. Interface Data Configuration




Ater Interface Data Configuration (over TDM)

A Interface Data Configuration (over IP)

A Interface Data Configuration (over TDM)

A Interface Data Configuration (over Transmission Resource


Pool)

Gb Interface Data Configuration (over IP)

Gb Interface Data Configuration (over FR)

Pb Interface Data Configuration (only Outer PCU need


configure)

Iur-g Interface Data Configuration (only interface between

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page81

BSSs or between a BSS and a RNS need configure)

Configuration Procedure (Gb over IP)


Configuring the Physical Layer
and Data Link Layer

ADD ETHIP
ADD ETHREDPORT(Optional)
ADD DEVIP(Optional)
ADD IPRT(Optional)

Set the PCU type

Add an SGSN node

Add an NSE

Configure an NSVL

ADD NSVLLOCAL
ADD NSVLREMOTE(Optional)

Add a PTPBVC

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page82

Basic

NSE

NSVL

PTPBVC

Configuring the Gb Interface (over IP)




Set the PCU type (SET BSCPCUTYPE)




Type : Inner

Add an SGSN node (ADD SGSNNODE)




OPNAME: Name of the operator. This parameter uniquely


identifies an operator

CNID : Identifies a node of SGSN with the operator name


uniquely

Add an NSE (ADD NSE)




Subnet protocol type : Gb over IP

Configuring Physical Layer and Data Link Layer

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page83

Basic

NSE

NSVL

PTPBVC

Configuring the Gb Interface (over IP)




Add an local NSVL (ADD NSVLLOCAL)




Local IP Address

Local UDP Port No. : UDP port number of the local NSVL


When Subnet Protocol Type of NSE is "Gb over IP" and


Subnetwork Configure Mode is "Static", the setting of this
parameter must be consistent with the setting at the SGSN side.

Value Range: 1214~2001, 2005~3783, 3786~4783, 4785~65000

Subrack No.

Slot No.

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page84

Basic

NSE

NSVL

Configuring the Gb Interface (over


IP)


PTPBVC

Add an remote NSVL (ADD NSVLREMOTE) (Optional)




If the NSE is in static configuration mode, run this


command to add an NSVL on the SGSN side.

Remote IP Address

Remote UDP Port No.: UDP port number of the remote


NSVL.


The setting of this parameter must be consistent with the setting


at the SGSN side.

Value Range: 0~65535

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page85

Basic

NSE

NSVL

Configuring the Gb Interface (over IP)




Add a PTPBVC (ADD PTPBVC)




NSE Identifier

PTP BVC Identifier

Index Type

Cell Index

Cell Name

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page86

PTPBVC

Contents


5. Interface Data Configuration




Ater Interface Data Configuration (over TDM)

A Interface Data Configuration (over IP)

A Interface Data Configuration (over TDM)

A Interface Data Configuration (over Transmission Resource


Pool)

Gb Interface Data Configuration (over IP)

Gb Interface Data Configuration (over FR)

Pb Interface Data Configuration (only Outer PCU need


configure)

Iur-g Interface Data Configuration (only interface between

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page87

BSSs or between a BSS and a RNS need configure)

Protocol Stack of the Gb Interface

LLC
relay
Relay

RLC

BSSGP

BSSGP

MAC

Network
Service

Network
Service

GSM RF

L1bis

L1bis

BSS

Gb

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

SGSN

Page88

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page89

Components of Gb Interface
data

BC(BCID)

PVC(DLCI)
PVC(DLCI)

data

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page90

NS Basic Concept


BC (Bearer Channel)


Consist of one group of time slots in one E1

DLCI (Data Link Connection Identifier)




The identifier of PVC having end-to-end significance across


the Gb interface

NSVC (Network Service Virtual Connection)




Provide end-to-end communication between the BSS and


SGSN irrespective of the exact configuration of the Gb
interface

NSE (NS entity)




Responsible for management of all of NSVC

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page91

Sub-Network Service Functions




The Sub-Network Service functions of the Network


Service shall provide access to the intermediate network
(or to the peer entity in case of direct point-to-point
configuration) and shall provide NS-VCs between NS peer
entities
Gb

FR Network

Gb

DTE

DTE
SGSN

BSS

DTE

Gb

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

DCE

Page92

NS Load-sharing
Two users in the same cell

SGSN
cell

BVC1

BSS

BVC2

BSSGP Layer

BVC1

BVC2
ms#1

ms#2
NSE3

NSE1
NSE2

NS Layer

NSVC channel=20

NSE1

NSE3
NSE2

DLCI=16

NSVC channel=10 DLCI=259

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page93

BSSGP Virtual Connections




BVC provide communication paths between BSSGP entities.


Each BVC is used in the transport of BSSGP PDUs between the
following entities:

peer point-to-point (PTP) functional entities

peer point-to-multipoint(PTM) functional entities

peer signalling functional entities

BVCI (BSSGP Virtual Connection Identifier)




The BVCI is used to enable the lower network service layer to


efficiently route the BSSGP PDU to the peer entity

PCU creates a BVC for each cell and assigns a BVCI for it , and then
sends them to SGSN via procedure, on which SGSN can create a

listHuawei Technologies Co., Ltd. All rights reserved.


Copyrightcell
2012

Page94

The Difference btw. PTP BVC and


SIG BVC
PTP BVC
SIG BVC

Cell1

Cell1

Cell2

NSE

NSE

Signaling

Cell2

NSVC1

User data
NSVC2
Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page95

Relations between the Objects to


be Configured

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page96

Configuration Procedure (Gb over FR)


Set the PCU type

SET BSCPCUTYPE

Add an SGSN node

ADD SGSNNODE

Add an NSE

ADD NSE

Add a BC

ADD BC

Add an NSVC

ADD NSVC

Add a PTPBVC

ADD PTPBVC

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page97

Basic

NSE

BC

NSVC

PTPBVC

Configuring the Gb Interface (over FR)




Set the PCU type (SET BSCPCUTYPE)




Type : Inner

Add an SGSN node (ADD SGSNNODE)




OPNAME: Name of the operator. This parameter uniquely


identifies an operator

CNID : Identifies a node of SGSN with the operator name


uniquely

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page98

Basic

NSE

BC

NSVC

PTPBVC

Configuring the Gb Interface (over FR)




Add an NSE (ADD NSE)




NSEI: Identifies a unique NSE

SRN: Subrack number of the XPU bound to the NSE

SN: Slot number of the XPU bound to the NSE

Subnet protocol type : Gb over FR

OPNAME: Name of the operator. This parameter uniquely


identifies an operator

CNID : Identifies a node of SGSN with the operator name


uniquely

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page99

Basic

NSE

BC

NSVC

Configuring the Gb Interface (over FR)




Add a BC (ADD BC)




Subrack No.

Slot No.

Port No.

BC Identifier

Bearing timeslot

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page100

PTPBVC

Basic

NSE

NSVC

BC

PTPBVC

Configuring the Gb Interface (over FR)




Add an NSVC (ADD NSVC)




NSVCIDX: NSVC index, identifies a unique NSVC

NSVCI: NSVC ID, identifies a unique NSVC. This ID must be


negotiated with the peer SGSN

NSEI: Identifies a unique NSE

SRN: Number of the subrack

SN: Number of the slot

BCID: Identifies one BC at the same port

DLCI: ID of the data link connection of the NSVC

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page101

Basic

NSE

BC

NSVC

Configuring the Gb Interface (over FR)




Add a PTPBVC (ADD PTPBVC)




NSE Identifier

PTP BVC Identifier

Index Type

Cell Index

Cell Name

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page102

PTPBVC

Contents


5. Interface Data Configuration




Ater Interface Data Configuration (over TDM)

A Interface Data Configuration (over IP)

A Interface Data Configuration (over TDM)

A Interface Data Configuration (over Transmission Resource


Pool)

Gb Interface Data Configuration (over IP)

Gb Interface Data Configuration (over FR)

Pb Interface Data Configuration (only Outer PCU need


configure)

Iur-g Interface Data Configuration (only interface between

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page103

BSSs or between a BSS and a RNS need configure)

Basic

PB E1/T1

Configuring the Pb Interface




Set the PCU type (SET BSCPCUTYPE)




Type : Outer

Add a PCU (ADD PCU)




PCU Name

PCU No.

Operator Name

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page104

PB SL

Basic

PB E1/T1

PB SL

Configuring the Pb Interface




Set the Pb interface E1/T1s (ADD PBE1T1)




Subrack No.

Slot No.

Port No.

PCU No.

Start PCIC: The value of Start PCIC must be the multiple of


128

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page105

Basic

PB E1/T1

Configuring the Pb Interface




Set the Pb interface signaling link (ADD PBSL)




Subrack No.

Slot No.

Port No.

Timeslot No.

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page106

PB SL

Contents


5. Interface Data Configuration




Ater Interface Data Configuration (over TDM)

A Interface Data Configuration (over IP)

A Interface Data Configuration (over TDM)

A Interface Data Configuration (over Transmission Resource


Pool)

Gb Interface Data Configuration (over IP)

Gb Interface Data Configuration (over FR)

Pb Interface Data Configuration (only Outer PCU need


configure)

Iur-g Interface Data Configuration (only interface between

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page107

BSSs or between a BSS and a RNS need configure)

interface
data

adjacent
RNC

external
3G cell

neighboring 3G
cell

Iur-g
connection

Configuring the Iur-g Interface




Add SCTP Signalling Link (ADD SCTPLNK)




Signalling link mode :Server/Client




Server mode: BSC6900 starts the listening and waits for the peer
to send the SCTP-INIT message.

Client mode: BSC6900 actively sends the SCTP-INIT message.

Application type :NBAP, M3UA, BBAP




The upper layer application type of A interface is M3UA.

Local/Destination SCTP port No.

First local/destination IP address

Second local/destination IP address

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page108

interface
data

adjacent
RNC

external
3G cell

neighboring 3G
cell

Configuring the Iur-g Interface




Add M3UA link set (ADD M3LKS)




Signalling link set index

Destination entity No.

M3UA signaling link name

Add an M3UA route (ADD M3RT)




Destination entity No

Signalling link set index

M3UA route name

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page109

Iur-g
connection

interface
data

adjacent
RNC

external
3G cell

neighboring 3G
cell

Configuring the Iur-g Interface




Add M3UA link (ADD M3LNK)




SCTP link No.

M3UA Signaling link name

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page110

Iur-g
connection

interface
data

adjacent
RNC

external
3G cell

neighboring 3G
cell

Iur-g
connection

Configuring the Iur-g Interface




Configure an adjacent RNC for the BSC(ADD GNRNC)




Co-MBSC:NO

Allow Common Measurement at Iur-g:NO

SupptCellLis:YES

Allow Info Exchange at Iur-g:YES

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page111

interface
data

adjacent
RNC

external
3G cell

neighboring 3G
cell

Iur-g
connection

Configuring the Iur-g Interface




Configure an external 3G cell (ADD GEXT3GCELL)




Cell Index

Cell Name

RNC ID

Neighboring RNC Index

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page112

interface
data

adjacent
RNC

external
3G cell

neighboring 3G
cell

Iur-g
connection

Configuring the Iur-g Interface




Configure a neighboring 3G cell (ADD G3GNCELL)




Index Type

Source Cell Index

Neighbor Cell Index

RSCP Offset

Ec/No Offset

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page113

interface
data

adjacent
RNC

external
3G cell

neighboring 3G
cell

Configuring the Iur-g Interface




Add an Iur-g connection(ADD GIURGCONN)




Neighboring RNC Index

Connection Type:EXTERNAL

Subrack No.

Slot No.

Subsystem No.

Peer Subrack No.

Peer Slot No.

Peer Subsystem No.

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page114

Iur-g
connection

Summary


We have configured the finished the BSC6900(GO) data


configuration, including: global data configuration,
equipment data configuration, interfaces data
configuration and clock cata configuration.

Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

Page115

Thank you
www.huawei.com

You might also like