Professional Documents
Culture Documents
1) As per PD 1096, what is the maximum distance of accessible parking area for the
physically handicapped from facility being served?
A.
B.
C.
D.
40 mtrs.
50 mtrs.
60 mtrs. (correct answer)
70 mtrs.
Q.2) For residential occupancies, how many percent of an interior lot is open space?
A. 25%
B. 30%
C. 40%
D. 50% (correct answer)
Q.3) As per PD 1096, what is the size of automobile parking slot for perpendicular or diagonal
parking?
A.
B.
C.
D.
2 x 5 mtrs.
2.5 x 5 mtrs. (correct answer)
2.15 x 6 mtrs
3 x 5 mtrs.
Q.4) Failure to commence the work within a period of ______months from the date of issuance
of permit is a basis for non-issuance, suspension or revocation of a Building Permit.
A. 3
B. 6
C. 8
D. 12 (correct answer)
Q.5) As per PD 1096, what is the minimum ceiling height of the first storey of a habitable room
provided with artificial ventilation?
A.
B.
C.
D.
2.00m
2.10 m
2.40 m
2.70 m
Q.6) As per PD 1096, what is the minimum clearance between the established grade of a street
and/or sidewalk and the lowest undersurface of any part of a projecting balcony?
A. 2.00m
B. 2.40m
C. 2.80m
D. 3.00m (correct answer)
Q.7) As per PD 1096, how many percent or parking requirements may be provided if adequate
public parking lots/multi-floor parking garages are available within 200 meters of the
proposed buildings/structures?
A.
B.
C.
D.
10 %
15 %
20 % (correct answer)
25 %
1.20m
1.80 m
2.00 m (correct answer)
2.10 m
Q.10) Which of the following is not covered in the framework of minimum standards and
requirements for buildings under PD 1096?
A. aesthetic value (correct answer)
B. maintenance
C. material quality
D. location
Q.11) As per PD 1096, what is the minimum clear width for Group A dwelling stairs?
A.
B.
C.
D.
0.71m
0.75m (correct answer)
0.80m
0.90m
Q.12) As per PD 1096, under what classification shall factories and workshops using less
flammable or non-combustible materials be classified?
A.
B.
C.
D.
Industrial
assembly
business and mercantile (correct answer)
accessory
Q.13) Which is not considered a basis of assessment for building permit fees?
A.
B.
C.
D.
cost of construction
floor area
lot area (correct answer)
building use
Q.14) As per PD 1096, what is the minimum front setback for a Residential R-1 lot?
A.
B.
C.
D.
3.00 mtrs.
3.50 mtrs.
4.50 mtrs. (correct answer)
5.00 mtrs.
Q.15) As per PD 1096, what is the minimum clear ceiling height for mezzanine floors above and
below it?
A.
B.
C.
D.
1.70m
1.80m (correct answer)
1.90m
2.00m
Q.16) As per PD 1096, a wheelchair transfer area is required for every how many parking spaces
Q.17) Which is not a ground for the non-issuance, suspension or revocation of a Building
Permit?
A.
B.
C.
D.
non-compliance to Code
inaccurate application
non-submittal of logbook (correct answer)
unauthorized change in plan
Q.18) As per PD 1096, what is the classification of buildings of masonry and wood construction
with a one-hour fire-resistivity throughout and exterior walls of incombustible fireresistive construction.
A. Type I
B. Type II
C. Type III (correct answer)
D. Type IV
Explanation
Type I - shall be of wood construction with structural elements permitted by the Code.
Type II - shall be of wood construction with protective fire-resistant materials and 1-hour
fire resistive throughout, except, that permanent non-bearing partitions may use fireretardant treated wood within the framing assembly with 1-hour resistivity. Type IV - shall
be of steel, iron, concrete, or masonry construction and walls, ceiling and permanent
partitions shall be incombustible fire-restive construction except that permanent nonbearing partitions of 1-hour fire resistive construction may use fire-retardant treated wood
within the framing assembly.
Q.19) As per PD 1096, what is referred to by the total number of persons that may occupy a
building or a portion thereof at any one time?
A.
B.
C.
D.
building occupancy
occupant load (correct answer)
building usage
unit capacity
Q.20) As per PD 1096, what is the minimum air space per person for a habitable room with
natural ventilation?
A.
B.
C.
D.
10 cum
12 cum
14 cum (correct answer)
16 cum
Q.21) As per PD 1096, what is the ratio of parking slot to gross floor area of office buildings?
A.
B.
C.
D.
1 slot/100 sqm.
1 slot/125 sqm. (correct answer)
1 slot/ 150 sqm
1 slot/200 sqm.
Tax Declaration
Latest Income Tax (correct answer)
plans and specifications
Current Real Property Tax Receipt
Q.23) As per PD 1096, what is the minimum width for access road to interior lots?
A.
B.
C.
D.
3m (correct answer)
4m
5m
6m
Q.24) As per PD 1096, under what classification shall gasoline filling and service stations be
classified?
A.
B.
C.
D.
assembly
business and mercantile (correct answer)
Industrial
accessory
Q.25) As per PD 1096, what is the ratio of parking slot to number of units in residential hotels
and apartels?
A. 1 slot / 5 units (correct answer)
B. 1 slot / 10 units
C. 1 slot / 15 units
D. 1 slot / 20 units
Q.26) As per PD 1185, what is the minimum aisle width for less than 60 seats in places of
assembly?
A.
B.
C.
D.
Q.27) As per PD 1185, what is the maximum number of seats in rows of seats between aisles for
places of assembly?
A. 5
B. 7
C. 12
D. 14 (correct answer)
Q.28) As per PD 1185, what is the unit of exit width used to measure means of egress?
A.
B.
C.
D.
50 cm.
55 cm. (correct answer)
60 cm.
65 cm.
Q.29) As per PD 1185, what is the minimum width for any single door in a doorway?
A.
B.
C.
D.
61 cm.
71 cm. (correct answer)
81 cm.
91cm.
Q.30) Passageway from one building to another or around a wall in approximately the same floor
level.
A. Fire Lane
B. Horizontal Exit (correct answer)
C. Public Way
D. Vestibule
Explanation
Fire Lane - The portion of a roadway or public way that should be kept opened and
unobstructed at all times for the expedient operation of firefighting units.
Public Way - Any street, alley or other strip of land unobstructed from the ground to the
sky, deeded, dedicated or otherwise permanently appropriated for public use.
Vestibule - A passageway or antechamber between the outer doors and the interior parts of
a house or building.
Q.31) As per PD 1185, between any point in an institutional sleeping room or suite and an exit
access door of that room or suite shall not exceed how many meters?
A.
B.
C.
D.
Q.32) Degree of hazard is determined by: i. Fire resistance rating ii. Probability that a building,
structure or facility may catch fire iii. Difficulty in evacuating people iv. Difficulty in
suppressing fire
A.
B.
C.
D.
i, ii, iii
ii, iii, iv (correct answer)
i, iii, iv
i, ii, iv
Q.33) As per PD 1185, what is the maximum force that is applied to the releasing device of the
panic hardware in the direction of exit travel that shall cause the door latch to release?
A.
B.
C.
D.
5 kilos
6 kilos
7 kilos (correct answer)
8 kilos
Q.35) As per PD 1185, what is the maximum travel distance for places of assembly if not
protected by automatic fire suppression system?
A. 46 mts. (correct answer)
B. 56 mts.
C. 61 mts.
D. 71 mts.
Q.36) As per PD 1185, dwelling units in row apartments shall be separated from each other by
partition walls having a fire resistance rating of how many hours?
A.
B.
C.
D.
1 hour
2 hour
3 hour
4 hour (correct answer)
Q.12) As per PD 1185, buildings over this height shall be required throughout with automatic
fire sprinkler system.
A.
B.
C.
D.
10m
12m
15m (correct answer)
18m
Q.13) As per PD 1185, which is not a factor for determining degree of hazard?
A.
B.
C.
D.
type of occupancy
construction materials used
combustibility of contents
floor area (correct answer)
Q.14) An extremely hot luminous bidge formed by passage of an electric current across a space
between two conductors or terminals due to the incandescence of the conducting vapor.
A. Pyrophoric
B. Flash Point
C. Electric Arc (correct answer)
D. Fulminate
Explanation
Pyrophoric - Descriptive of any substance that ignites spontaneously when exposed to air.
Flashpoint - The minimum temperature at which any matrial gives off vapor in sufficient
concentration to form an ignitable mixture with air.
Fulminate - A kind f stable explosive compound which explodes by percussion.
Q.15) Separated from other spaces of the building or structure by construction or equipment to
provide a protected way of travel to the exit discharge.
A. Fire Lane
B. Horizontal Exit
Q.17) A rocket or liquid propellant which consist of combinations of fuels and oxidizers which
ignite spontaneously on contact with each other.
A. Hypergolic Fuel (correct answer)
B. Cryogenic
C. Corrosive Liquid
D. Combustible Liquid
Explanation
Cryogenic - Descriptive of any mateial which by its nature or as a result of its reaction
with other elements produces a rapid drop in temperature of the immediate surroundings.
Corrosive Liquid - Any liquid which causes fire when in contact with organic matter or
with certain chemicals.
Combustible Liquid - Any liquid having a flash point at or above 37.8 C (100 F).
Q.18) As per PD1185, what is the minimum headroom clearance for Class B stairs?
A.
B.
C.
D.
Q.19) As per PD 1185, under what classification does fire in flammable liquids and gasses
belong to?
A. Class A
B. Class B (correct answer)
C. Class C
D. Class D
Explanation
Class A - fire involving ordinary combustible materials such as wood, cloth, paper, rubber
and plastics
Class C -fire involving energized electrical equipment
Class D -fire involving combustible metals such as magnesium, sodium, potassium
Q.20) A bar which extends across at least one-half of each door leaf, which will open the door if
subjected to pressure.
A.
B.
C.
D.
Flush bolt
Door jamb
Door handle
Panic hardware (correct answer)
Q.22) As per PD 1185, what is the minimum number of exits for Class A places of assembly
with a capacity of more than 1,000 persons?
A.
B.
C.
D.
2
3
4 (correct answer)
6
Q.23) Descriptive of any material which by its nature or as a result of its reaction with other
elements produces a rapid drop in temperature of the immediate surroundings
A. Oxidizing Material
B. Cryogenic (correct answer)
C. Combustible Liquid
D. Pyrophoric
Explanation
Oxidizing Material - A material that readily yields oxygen in quantities sufficient to
stimulate or support combustion.
Combustible Liquid - Any liquid having a flash point at or above 37.8 C (100 F)
Pyrophoric - Descriptive of any substance that ignites spontaneously when exposed to air
Q.24) A building unsafe in case of fire because it will burn easily or because it lacks adequate
exits or fire escapes.
A. Fire Abatement
B. Fire Lane
C. Fire Hazard
D. Fire Trap (correct answer)
Explanation
(Fire) Abatement - Any act that would remove or neutralize a fire hazard.
Fire Lane - The portion of a roadway or publicway that should be kept opened and
unobstructed at all times for the expedient operation of fire fighting units.
Fire Hazard - Any condition or act which increases or may cause an increase in the
probability of the occurrence of fire, or which may obstruct, delay, hinder or interfere with
fire fighting operations and the safeguarding of life and property
Q.25) As per PD 1185, every room or space in educational occupancies with a capacity of over
50 persons shall have at least how many doorways?
A. 1 doorway
B. 2 doorways (correct answer)
C. 3 doorways
D. 4 doorways
Q.1) As per BP 220, which among the following is the highest in the heirarchy of basic needs of
human settlements, the provision of which shall be based on the actual setting which the
project is located?
A.
B.
C.
D.
park/playground
power
water (correct answer)
movement and circulation
Q.2) As per BP 344, how much is the parking slot width for handicapped drivers and
passengers providing sufficient clear space between parked cars to allow them to transfer
to a wheelchair?
A.
B.
C.
D.
3.6 mtrs.
3.7 mtrs. (correct answer)
3.8 mtrs.
3.9 mtrs.
Apartelle
Townhouse
Apartment
Condominium (correct answer)
Q.4) As per BP 220, how many percent of the gross subdivision area shall be allocated for
community facilities if the density is not more than 150 dwelling units per hectare in
socialized housing?
A.
B.
C.
D.
1% (correct answer)
1.5%
2%
2.5%
Q.6) As per BP 220, maintain a ratio for house and lot where ___% of the selling price for a
house and lot package is allotted for the house and ____% for the lot.
A.
B.
C.
D.
Q.7) As per PD 957, what is the prescribed ratio for saleable and non-saleable lots?
A.
B.
C.
D.
60% / 40%
70% / 30% (correct answer)
75% / 25%
80% / 20%
Q.8) As per BP 220, what is the minimum distance between buildings with more than 4
storeys?
A.
B.
C.
D.
6 mrs.
8 mtrs.
10 mtrs. (correct answer)
12 mtrs.
Q.9) As per BP 344, a level area of not less than how many meters shall be provided at the top
and bottom of any ramp?
A.
B.
C.
D.
1.4 mtrs.
1.5 mtrs.
1.8 mtrs. (correct answer)
1.9 mtrs.
Q.10) As per BP 220, how many percent of the gross subdivision area shall be allocated for
parks and playgrounds if the density is 250 dwelling units per hectare in socialized
housing?
A.
B.
C.
D.
9% (correct answer)
10%
12%
15%
Q.11) As per PD 957, what is the maximum block length without an alley?
A.
B.
C.
D.
Q.12) As per BP 220, what is the minimum dimension for stairway tread and riser respectively?
A.
B.
C.
D.
Q.13) As per BP 344, what is the maximum length of a ramp if the ramp gradient is 1:12?
A. 4 mtrs.
Q.15) What basic principle is applied in the basic planning requirements? of BP 344
standards so that finding a person's way inside and outside of a building or open space
shall be made easy for everyone?
A. Accessibility
B. Usability
C. Reachability
D. Orientation (correct answer)
Explanation
Accessibility - The built environment shall be designed so that it shall be accessible to all
people. This means that no criteria shall impede the use of facilities by either the
handicapped or non-disabled citizens.
Usability - The built environment shall be designed so that all persons, whether they be
disabled or not, may use and enjoy it.
Reachability - Provisions shall be adapted and introduced to the physical environment so
that as many places or buildings as possible can be reached by all.
Q.16) What is the minimum floor area for open market housing units as per PD 957?
A.
B.
C.
D.
22 sqm
30 sqm
42 sqm (correct answer)
54 sqm
Q.17) What is the minimum lot area for single-detached socialized housing units as provided for
in BP 220?
A.
B.
C.
D.
54 sqm.
62 sqm.
64 sqm. (correct answer)
72 sqm.
Q.18) As per PD 957, parks/playground or other recreational facilities may not be required if the
condominium is located not more than or _____ meters from a publicly accessible
park/playground/or other recreational facilities.
A.
B.
C.
D.
200
400
800 (correct answer)
1000
Q.19) As per BP 344, entrances with vestibules shall be provided with at least how much depth
to allow a disabled person to open the door and allow his wheelchair to pass through
easily?
A.
B.
C.
D.
1.8 mtrs.
2.4 mtrs.
3.0 mtrs
3.5 mtrs.
Q.20) As per BP 344, accessible public washrooms and toilets shall permit easy passage of a
wheelchair and must allow how much turning space for wheelchairs?
A. 1.50 sqm.
B. 1.70 sqm.
C. 2.0 sqm.
D. 2.25 sq. (correct answer)
Explanation
1.5 x 1.5 = 2.25 SQM
Q.21) What is the minimum floor area for economic housing units as provided for in BP 220?
A.
B.
C.
D.
16 sqm.
18 sqm.
20 sqm.
22 sqm. (correct answer)
Q.22) As per BP 220, what is the maximum length for rowhouse units?
A.
B.
C.
D.
50 mtrs.
100 mtrs. (correct answer)
150 mtrs.
250 mtrs.
Q.23) As per BP 220, what is the minimum area for parks and playgrounds?
A.
B.
C.
D.
50 sqm.
100 sqm. (correct answer)
150 sqm.
200 sqm.
Q.24) As per PD 957, what is the minimum floor area of family condominium units for open
market?
A. 18
B. 22
C. 32
D. 36 (correct answer)
Q.25) What is the minimum lot frontage for rowhouse units in economic housing as provided for
in BP 220?
A.
B.
C.
D.
3 mtrs.
3.5 mtrs. (correct answer)
4 mtrs.
4.5 mtrs.
Q.26) As per PD 957, what is the minimum area for a single park/playground in a residential
condominium project?
A.
B.
C.
D.
Q.27) Which of the following is not included in the outline prescribed by the Department of
Environment and Natural Resources for the preparation of an Environmental Impact
Statement?
A.
B.
C.
D.
Project Setting
Mitigation Measures
Contingency Plans
Project Cost (correct answer)
Q.28) What is the minimum lot frontage of a regular lot for single-detached units as provided for
in BP 220?
A.
B.
C.
D.
4 mtrs.
6 mtrs.
8 mtrs. (correct answer)
10 mtrs.
Q.29) As per PD 957, what is the minimum lot frontage of an interior lot for single-detached
units?
A.
B.
C.
D.
Q.30) As per BP 344, what is the maximum distance between reststops of turn-around spaces in
walkways?
A. 5 mtrs.
B. 6 mtrs.
C. 10 mtrs.
D. 12 mtrs. (correct answer)
Q.31) A dwelling on one lot containing separate living units for 3 or more families, usually
provided with common access, services, and use of land?
A.
B.
C.
D.
cluster housing
multi-family dwelling (correct answer)
rowhouse
planned unit development
Q.32) As per BP 220, what is the minimum distance between two buildings wherein the taller
building has 3 or 4 storeys?
A.
B.
C.
D.
4 mtrs.
5 mtrs.
6 mtrs. (correct answer)
7 mtrs.
Q.33) As per BP 220, which is not a site criteria for determining whether an economic and
socialized housing shall be allowed?
A.
B.
C.
D.
Q.34) As per BP 220, which of the following is not an important planning consideration for
circulation system layout?
A.
B.
C.
D.
Q.35) As per BP 344, how long is the extension of handrails which shall be provided from the
start and end of ramps and stairs?
A.
B.
C.
D.
150 mm.
200 mm.
250 mm.
300 mm. (correct answer)
Q.36) As per BP 220, what is the maximum length of an alley in a residential block?
A.
B.
C.
D.
20 mtrs.
40 mtrs.
60 mtrs. (correct answer)
80 mtrs.
Q.37) As per BP 344, what is the required minimum walkway width to permit a person in
wheelchair to traverse it with safety?
A.
B.
C.
D.
1.10 mtrs.
1.20 mtrs.
1.25 mtrs.
1.5 mtrs.
Q.38) What is the minimum lot area for open market rowhouse units as prescribed in PD 957?
A. 50 sqm.
B. 60 sqm.
C. 70 sqm.
D. 80 sqm.
Q.39) As per BP 344, how many seats shall be designated for disabled persons in passenger
trains?
A.
B.
C.
D.
2
4
6 (correct answer)
8
Q.40) As per PD 957, what is the minimum width for roads or right -of-way for residential
condominium projects?
A. 6 mtrs.
B. 8 mtrs. (correct answer)
C. 10 mtrs.
D. 12 mtrs.
Q.1) Bath and toilets shall have a minimum area of ______ with a least dimension of ______.
A.
B.
C.
D.
Q.2) Minimum access road width for interior or rear lots on which more than 35 units of
apartments, rowhouses or accesorias or group of single detached units are built
A. 4.00m
B. 5.00m
C. 6.00m
D. 7.50m (correct answer)
Q.3) The maximum height and number of stories of every building shall be dependent upon the
following: --;-- i.Character of occupancy--;-- iii. Environmental conditions--;-- ii.Type of
construction --;-- iv. Capacity of public utility/service systems
A. i, ii, iii
B. i, iii, iv
C. i, ii, iv
9 cubic mts.
12 cubic mts.
14 cubic mts. (correct answer)
16 cubic mts
Q.5) The point of reference on the highest adjoining sidewalk or the highest adjoining ground
surface.
A.
B.
C.
D.
Q.6) The lowest point of elevation of the finished surface of the ground between the exterior
wall of a building and a point 1.50 meters distant from the said wall.
A.
B.
C.
D.
Q.7) An unoccupied space other than a yard bounded on all sides or around its periphery by
building lines
A.
B.
C.
D.
Q.8) Minimum air space per person for workshop, factories, and offices
A.
B.
C.
D.
9 cubic mts.
12 cubic mts. (correct answer)
14 cubic mts.
16 cubic mts
Q.9) Rooms intended for any use without any artificial ventilation shall have windows with a
total free area of openings equal to at least ____ percent of the floor area of the room but
such opening shall not be less than 1.0 sqm.
A.
B.
C.
D.
5
10 (correct answer)
15
20
Q.10) The classification based on the fire resistivity ratings of materials and methods of
construction of buildings/structures or portions thereof.
A.
B.
C.
D.
Character of occupancy
Type of construction (correct answer)
Fire zone
Fire hazard
Q.12) The vertical distance from the established grade elevation to the highest point of the
opening of a flat roof, to the average height of the coping of a flat roof, to the average
height of the highest gable, pitch or hip roof or to the top of the parapet, if the roof is
provided with a parapet, whichever is higher.
A.
B.
C.
D.
Q.13) Minimum ceiling height measured from the floor to the ceiling of habitable rooms with
natural ventilation
A.
B.
C.
D.
2.0 mts.
2.4 mts.
2.7 mts. (correct answer)
3.0 mts.
Q.14) Rooms for human habitations shall have a minimum area of ______ with a least
dimension of ______.
A.
B.
C.
D.
4 sqm.; 2 mts.
6 sqm.; 2 mts. (correct answer)
6 sqm.; 3 mts.
9 sqm.; 3 mts.
Q.15) Minimum air space for school rooms shall be _____cubic meters with ____ square meter
of floor area per person
A.
B.
C.
D.
Q.16) When the horizontal distance between the outermost portion face of the building and the
inner edge of the sidewalk is more than one-half the height of the building, only a fence is
required as protection during construction. Height of fence is ___.
A.
B.
C.
D.
1.8 mts.
2.0 mts.
2.4 mts. (correct answer)
3.00 mts.
1.2 mts.
2.0 mts (correct answer)
2.4 mts.
3.0 mts.
Q.18) An unoccupied space other than a yard bounded on two opposite sides by building lines
with the other opposite side bounded by other open spaces whether public or private.
A.
B.
C.
D.
Inner court
Open court
Through court (correct answer)
Private court
Q.19) Which of the following statements are not true? --i. No building shall be constructed
unless it adjoins or has direct access to a public space, yard or street on at least one of its
sides--;-- ii. Where length of run for access to interior lots is 200 mts, a cul-de-sac or turn
court shall be provided for each maximum run of 50 mts.--;-- iii. Parking space shall be
provided inclusive of access road requirement when number of independent living units
with individual entrances is increased as in multi-story apartments.--;-- iv. Only some
specificbuildings shall face a public street, alley or a private road.
A. i and ii
B. ii and iii
C. iii and iv (correct answer)
D. None of the above
Explanation
iii. Parking space shall be provided "exclusive" of access road requirement when number
of independent living units with individual entrances is increased as in multi-story
apartments.; iv. "All" buildings shall face a public street, alley or a private road.
Q.20) Minimum width of access road for interior or rear lots
A.
B.
C.
D.
Q.21) Minimum ceiling height measured from the floor to the ceiling of habitable rooms
provided with artificial ventilation
A.
B.
C.
D.
1.8 mts.
2.0 mts.
2.4 mts. (correct answer)
2.7mts.
Q.22) Toilet and bath rooms, laundry rooms and similar rooms shall be provided with window or
windows with an area of not less than _____ of the floor area of such rooms, and such
openings shall not be less than 240 sq. mm.
A. 1/5
B. 1/10
C. 1/15
D. 1/20 (correct answer)
Q.23) An unoccupied space other than a yard bounded on three sides by building lines with one
side bounded by another open space whether public or private.
A.
B.
C.
D.
Inner court
Open court (correct answer)
Through court
Private court
Q.24) Kitchens shall have a minimum area of ______ with a least dimension of ______.
A.
B.
C.
D.
3 sqm.; 1 mtr.
4.5 sqm.; 1.5 mts
6 sqm.; 3 mts.
3 sqm.; 1.5 mts. (correct answer)
2 (correct answer)
3
4
5
Q.2) That part of any wall entirely above the roof line
A.
B.
C.
D.
Fire wall
Curtain wall
Parapet wall (correct answer)
Retaining wall
Q.3) For markets, minimum required parking is 1 slot per how many sqm of market floor area.
A.
B.
C.
D.
50
100
150 (correct answer)
200
Q.4) For motels, minimum required parking is 1 slot per how many units.
A.
B.
C.
D.
1 (correct answer)
2
3
4
Q.5) Any wall which subdivides a building so as to resist the spread of fire, by starting at the
foundation and extending continuously through the storey to, or above the roof.
A.
B.
C.
D.
party wall
Foundation wall
Firewall (correct answer)
Nonbearing wall
Q.6) For hospitals, minimum required parking is 1 slot per how many beds.
A.
B.
C.
D.
15
20
25 (correct answer)
30
Q.7) For neighborhood shopping center, minimum required parking is 1 slot per how many sqm
of shopping floor area.
A.
B.
C.
D.
25
50
75
100 (correct answer)
Q.8) The floor area assigned to that use divided by the unit area per occupant.
A.
B.
C.
D.
density
Occupant load (correct answer)
Building bulk
Floor area ratio
Q.9) For public assembly buildings such as theaters, cinemas, auditoria, stadia, etc., minimum
required parking is 1 slot per how many sqm of spectator area.
A. 50 (correct answer)
B. 100
C. 150
D. 200
Q.10) For elementary, secondary, vocational and trade schools, minimum required parking is 1
slot per how many classrooms.
A.
B.
C.
D.
5
10 (correct answer)
15
20
Q.11) Parking areas for the physically handicapped shall be within how many meters of the
facility being served measured from the farthest parking space along accessible path to the
closest accessible distance.
A.
B.
C.
D.
30
40
60 (correct answer)
80
Q.12) Multi-family living units regardless of number of stories with an average living unit floor
area above 50 sqm to 100 sqm shall have 1 parking slot per how many living units.
A.
B.
C.
D.
1
4 (correct answer)
8
10
Q.13) The enclosing wall of an iron or steel or the nonbearing portion of an enclosed wall
between piers.
A.
B.
C.
D.
Q.14) Any wall used to resist the lateral displacement of any material; a subsurface wall built to
resist the lateral pressure of internal loads.
A. party wall
B. Curtain wall
C. Foundation wall
D. Retaining wall (correct answer)
Q.15) For buildings/structures intended for the use or occupancy of the handicapped, a minimum
provision of one parking slot for the handicapped per 50 parking lots up to _____ parking
slots and an additional slot for every 100 slots thereafter.
A.
B.
C.
D.
100
150 (correct answer)
200
250
Q.16) One wheelchair transfer area is to be provided in every ___ parking spaces directly
connected to accessible walks of travel and accessible building entrances.
A.
B.
C.
D.
2 (correct answer)
4
6
8
Q.17) For hotels, minimum required parking is 1 slot per how many rooms.
A.
B.
C.
D.
2
4
8
10 (correct answer)
Q.18) Low-income single-detached living units in housing project areas with individual lots not
more than 100 square meters shall have a pooled parking at 1 slot per how many living
units.
A.
B.
C.
D.
5
10 (correct answer)
15
20
Q.19) For places of worship and funeral parlors, minimum required parking is 1 slot per how
many sqm of congregation area.
A. 50 (correct answer)
B. 100
C. 150
D. 200
Q.20) For office buildings, minimum required parking is 1 slot per how many sqm of gross floor
area.
A.
B.
C.
D.
50
100
125 (correct answer)
150
Q.21) For residential hotels and apartels, minimum required parking is 1 slot per how many
units.
A.
B.
C.
D.
2
5 (correct answer)
8
10
Q.22) Multi-family living units regardless of number of stories with an average living unit floor
area of more than 100 sqm shall have 1 parking slot per how many living units.
A.
B.
C.
D.
1 (correct answer)
4
8
10
Q.23) For clubhouses, beach houses, and the like, minimum required parking is 1 slot per how
many sqm of gross floor area.
A.
B.
C.
D.
50
75
100 (correct answer)
125
Q.24) Multi-family living units regardless of number of stories with an average living unit floor
area of up to 50 sqm shall have 1 parking slot per how many living units.
A. 1
B. 4
C. 8 (correct answer)
D. 10
Q.25) For colleges and universities, minimum required parking is 1 slot per how many
classrooms.
A.
B.
C.
D.
5 (correct answer)
10
15
20
Q.1)
A movable shelter supported entirely from the exterior wall of a building and of a type
which can be retracted, folded, or collapsed against the face of a supporting building
A.
B.
C.
D.
Canopy
Accessoria
Awning (correct answer)
Arcade
Q.2) Multi-family living units regardless of number of stories with an average living unit floor
area above 50 sqm to 100 sqm shall have 1 parking slot per how many living units.
A.
B.
C.
D.
1
4 (correct answer)
8
10
Q.3) As per PD 1096, floors above the first storey in all types of occupancies having an
occupant load of more than ten (10) shall not have less than how many exits?
A.
B.
C.
D.
1
2 (correct answer)
3
4
Q.4)
Standpipes shall be located within the following areas.
i. Enclosed stairway landings or near such stairways
Through lot
Inside lot (correct answer)
Interior lot
Corner lot
Q.6) As per PD 1096, what is the maximum slope for the ramp joining the driveway to the
sidewalk whenever a driveway is to be constructed across the entire width of the sidewalk
with a curb height of more than 200mm?
A. 1/3
B. 1/4
C. 1/6
D. 1/8 (correct answer)
Q.7) A vertical opening through a building for elevators, dumbwaiters, mechanical equipment,
or similar purposes.
A.
B.
C.
D.
Soffit
Chute
Air space
Shaft (correct answer)
Q.8) A projecting window similar to a bay window, but carried on brackets or corbels.
A. Oriel window (correct answer)
B. Canopy window
C. Double-hung window
D. French window
Q.9) The line formed by the intersection of the outer surface of the enclosing wall of the
building and the surface of the ground.
A.
B.
C.
D.
Q.10) Every building with _______storeys in height shall be equipped with one or more dry
standpipes.
A. one to two
B. two to three
C. three to four
D. four or more (correct answer)
Q.11) A building permit shall be suspended or revoked if authorized work is abandoned after it
has been commenced for a period of not less than how many calendar days?
A.
B.
C.
D.
60 days
80 days
100 days
120 days (correct answer)
Q.12) Standard automatic fire extinguishing systems shall be installed in every storey, basement
or cellar with an area of ____square meters or more which is used for habitation,
recreation, dining, study or work, and which has an occupant load of more than 20.
A.
B.
C.
D.
100
150
200 (correct answer)
250
Q.13)
A yard or court providing egress to a public way for one or more required units.
A. Court yard
B. Horizontal exit
C. Exit courts (correct answer)
D. Setback
Q.14) As per PD 1096, what is the total open space within lots (TOSL) for basic R-2
buildings/structures on basic R-2 corner lot using minimum sizes?
A.
B.
C.
D.
30%
50%
58% (correct answer)
62.5%
Q.15)
A wall separating two or more buildings, and used in common by the said buildings
A.
B.
C.
D.
Fire wall
Party wall (correct answer)
Dead wall
Faced wall
Q.16) As per PD 1096, what is the minimum horizontal distance between the curb line and the
outermost face of any part of the arcade that is cantilevered from the building line over the
sidewalk?
A.
B.
C.
D.
Q.17) As per PD 1096, A.T.O. need not be consulted if buildings/structures is not more than how
many meters in height beyond the 315 mtrs. or 500 mtrs. distance from strip edge?
A.
B.
C.
D.
15 mtrs.
30 mtrs.
45 mtrs. (correct answer)
60 mtrs.
Q.18) As per PD 1096, rooms intended for any use, not provided with artificial ventilation
system, shall be provided with a window or windows with a total free area of openings
equal to at least how many percent of the total floor area of the room?
A.
B.
C.
D.
Q.19) Any portion of a building above the first floor projecting over the sidewalk beyond the
first-storey wall used as protection for pedestrians against rain or sun.
A.
B.
C.
D.
Canopy
Accessoria
Awning
Arcade (correct answer)
Q.20) The total aggregate area of plastics used in skylights, monitors, and sawtooth glazing shall
not exceed how many percent of the floor area of the room or occupancy sheltered.
A.
B.
C.
D.
10
15
20 (correct answer)
25
Q.21) The vacant space left between the building and the property lines.
A.
B.
C.
D.
Q.22) As per PD 1096, what is the range of slope of the entry ramp of the driveway connecting
the roadway surface to the sidewalk surface?
A.
B.
C.
D.
1/2 to
1/2 to 1/3
1/3 to (correct answer)
1/3 to 1/5
Q.23) All dry standpipes shall be equipped with this fire department connection which is located
on a street front of the building and not less than 300mm nor more than 1.20 mtrs above
the grade and shall be equipped with clapper checks and substantial plugs.
A.
B.
C.
D.
Outlet
Siamese twin (correct answer)
Flues
Dampers
Q.24) A structural unit, the integral parts of which have been built up or assembled prior to
incorporation in the building
A.
B.
C.
D.
Q.25) As per PD 1096, what is the width of the access road directly connecting multiple living
units of 16 to 25 units on same lot to a public street or alley?
A.
B.
C.
D.
3 mtrs.
4 mtrs.
5 mtrs. (correct answer)
6 mtrs.
Q.26) The number of wet standpipes when required shall be so determined that all portions of
the building are within 6.0 meters of a nozzle attached to a hose ____ meters in length
A.
B.
C.
D.
20
21
22 (correct answer)
23
Q.27) As per PD 1096, the parking requirements for mixed occupancies shall be the sum of ____
% of the dominant use and _____% of the each of the non-dominant use.
A.
B.
C.
D.
75% / 25%
25% / 75%
50% / 100%
100% / 50% (correct answer)
Q.28) As per PD 1096, repair garages and shops shall fall under what occupancy classification?
A. Group D
B. Group E
C. Group F
Schools
Churches
public markets (correct answer)
museums
Q.30) As per PD 1096, what is the minimum width of a planting strip on the outer side of a
sidewalk of 2 meters in width or more, separating the curb from the sidewalk pavement?
A. 500 mm
B. 600 mm
C. 800 mm (correct answer)
D. 900 mm
Q.1) Time in which flame will spread over the surface of a burning material
A.
B.
C.
D.
Q.2) Designed to prevent spread of fire, having a fire resistance of not less than 4 hours with
sufficient structural stability to remain standing even if construction on either side
collapses under fire conditions.
A.
B.
C.
D.
Incombustible material
Fire wall (correct answer)
Organic coating
Fire retardant
Q.3) This is separated from all other spaces of the building or structure by construction or
equipment to provide a protected way of travel to the exit discharge.
A. Door itself
B. Exit/egress access
damper
Fire exit
Shutter (correct answer)
Fire retardant
Q.6) Combination of an automatic fire or smoke detection system and a system of high velocity
water spray nozzle
A. Sprinkler vent method
B. Spray nozzle method (correct answer)
C. Rolling shutter method
Fire coating
Fire softener
Organic coating (correct answer)
Fire retardant
Q.8) A mechanical device consisting of linkages and a horizontal bar across a door, which
when pushed from inside will case the door to open and facilitate exit from a building.
A.
B.
C.
D.
Flushbolt
Panic hardware (correct answer)
Exit handle
Door latch
Q.9) A fire alarm system activated by the presence of a fire, where the signal is transmitted to
designated locations instead of sounding a general alarm, in order to prevent panic.
A.
B.
C.
D.
Q.10) Time duration that a material or construction can withstand the effect of a hundred fire test
A.
B.
C.
D.
Q.11) When a door discharges to the outside, change in floor level shall not be more than how
many millimeters?
A.
B.
C.
D.
202mm
205mm (correct answer)
207mm
215mm
Q.12)
Degree of hazard is determined by:
i. Fire resistance rating
ii. Probability that a building, structure or facility may catch fire
iii. Difficulty in evacuating people
iv. Difficulty in suppressing fire
A.
B.
C.
D.
i, ii, iii
ii, iii, iv (correct answer)
i, iii, iv
i, ii, iv
Q.13) The assembly of a fire door, fire window or fire damper, including all required hardware,
anchorage, frames and sills.
A.
B.
C.
D.
Q.14) Single door in a doorway for exits shall not be less than 0.71m and not more than how
many meters?
A.
B.
C.
D.
1.05 mtrs
1.10 mtrs
1.20 mtrs.
1.22 MTRS. (correct answer)
Q.15) A rating of combustible material based on the density and volume of smoke developed
within a certain period of time when its surface is ignited.
A.
B.
C.
D.
Q.16)
For stairs used as exits, minimum number of risers in any one flight is ___ ?
A.
B.
C.
D.
2
3 (correct answer)
4
5
Q.17)
The Egress system is made up of the following
i. door itself
ii. exit/egress access
iii. The exit
iv. Exit discharge
A.
B.
C.
D.
i, ii, iii
ii, iii, iv (correct answer)
i, iii, iv
i, ii, iv
Q.18) A continuous and unobstructed route of exit from any point in a building, structure or
facility to a public way.
A.
B.
C.
D.
Q.19) A way of passage from one building to an area of refuge in another building on
approximately the same level.
A.
B.
C.
D.
Exit passageway
Exit width
Horizontal exit (correct answer)
Discharge area
Q.20)
Means of egress between the termination of an exit and a public way.
A.
B.
C.
D.
Door itself
Exit/egress exit
The exit
Exit discharge (correct answer)
Q.21) Combination of an automatic or smoke detection system, automatic exhaust system and an
automatic water curtain
A.
B.
C.
D.
Q.23) A bar which extends across at least one-half of each door leaf, which will open the door if
subjected to pressure.
A.
B.
C.
D.
Flush bolt
Door jamb
Door handle
Panic hardware (correct answer)
Q.24) Any compound or mixture, which when applied properly improves the fire resistant
quality of fabrics and other materials.
A.
B.
C.
D.
Fire coating
Incombustible
Organic coating
Fire retardant (correct answer)
Q.25) A fire assembly which may remain in an open position and which will close automatically
if subjected to either of the following conditions.
A. Self-closing fire assembly (correct answer)
B. Fire damper
C. Shutter
D. Fire protection system
Q.1) For educational occupancies, minimum occupant load for shops, laboratories, and
vocational rooms.
A.
B.
C.
D.
Q.3)
Concealed space in which exposed materials with flame-spread rating greater than class A
are fire-stopped
A.
B.
C.
D.
Q.4) Aisle width for more than 60 seats in multiple seating for places of assembly.
A.
B.
C.
D.
Q.5)
Automatic self-closing rolling shutter which completely encloses the top of each escalator
A.
B.
C.
D.
Q.6) What is the maximum travel distance for places of assembly if protected by automatic fire
suppression?
A.
B.
C.
D.
41
51
61 (correct answer)
71
Q.7) For educational occupancies, minimum occupant load for dry nurseries with sleeping
facilities.
A.
B.
C.
D.
1.25 sqm/person
2.25 sqm/person
3.25 sqm/person (correct answer)
4.25 sqm/person
Q.8) Every room or space with a capacity of over 50 persons or over 93 sqm in area shall have
at least how many doorways providing access to separate exits.
A.
B.
C.
D.
1
2 (correct answer)
3
4
Q.9)
A device that contains within it chemicals, fluids, or gases for extinguishing fires, the
means for application of its contents for that purpose, and is capable of being readily
moved from place to place
A. Fire hose reel
B. Fire sprinkler
C. Fire extinguisher (correct answer)
D. Smoke control
Q.10) A fire line system without a constant water supply, is equipped with a fire service inlet and
outlet connections and installed exclusively for the use of the Fire Service
A.
B.
C.
D.
Q.11) For multiple seating in places of assembly, rows of seats between aisles shall have this
maximum number of seats.
A.
B.
C.
D.
7
9
11
14 (correct answer)
0.63 mtrs
0.73 mtrs
0.83 mtrs (correct answer)
0.93 mtrs.
0.80 sqm/person
1.80 sqm/person (correct answer)
2.80 sqm/person
3.80 sqm/person
Q.14) Minimum occupant load for business occupancies as well as industrial occupancies
A.
B.
C.
D.
6.3 sqm/person
7.3 sqm/person
8.3 sqm/person (correct answer)
9.3 sqm/person
Q.15) Kiosk designed to provide an effective barrier to the spread of smoke from floor to floor
A.
B.
C.
D.
Q.16)
A hose connection at grade or street level for use by the Fire Service only
A.
B.
C.
D.
Siamese twin
Fire Department house connection (correct answer)
Fire Department hose connector
Fire hose reel
Q.17) A fire line system with a constant water supply and installed for the use of the Fire Service
and the occupants of the building
A.
B.
C.
D.
Dry standpipe
Combination standpipe (correct answer)
Wet standpipe
Fire assembly
Q.18)
Minimum occupant load for standing room or waiting space in places of assembly.
A.
B.
C.
D.
0.18 sqm/person
0.28 sqm/person (correct answer)
0.38 sqm/person
0.48 sqm/person
Q.19) An auxiliary fire line system with a constant water supply installed primarily for
emergency fire use by the occupant of the building
A.
B.
C.
D.
Dry standpipe
Combination standpipe
Wet standpipe (correct answer)
Fire assembly
Q.20)
Minimum occupant load for concentrated use without fixed seats in places of assembly
such as auditorium, church, dance floor, lodge room
A.
B.
C.
D.
0.55 sqm/person
0.65 sqm/person (correct answer)
0.75 sqm/person
0.85 sqm/person
Q.21) Minimum occupant load for less concentrated use in places of assembly such as
conference room, dining room, exhibit room, gymnasium
A.
B.
C.
D.
Q.22) What is the maximum travel distance for places of assembly if not protected by automatic
fire suppression?
A.
B.
C.
D.
26
36
46 (correct answer)
56
Q.23) Aisle width for less than 60 seats in multiple seating for places of assembly.
A.
B.
C.
D.
0.66 mtrs.
0.76 mtrs. (correct answer)
0.86 mtrs.
0.96 mtrs.
Q.24) Buildings over this height shall be provided throughout with automatic sprinkler
protection.
A.
B.
C.
D.
12 mtrs.
15 mtrs. (correct answer)
18 mtrs.
21 mtrs.
Q.25) Minimum occupant load for residential occupancies except for single and 2-family
dwellings.
A.
B.
C.
D.
15.60 sqm/person
16.60 sqm/person
17.60 sqm/person
18.60 sqm/person (correct answer)