METERING STANDARDS
Section: Technical Guidelines
PM-DME-900.01
Page 1 of 5
Rev. Code: 5
Effectivity Date: September 1, 2012
1.1
Location
Designation
st
1
Character
(alpha
Application
Type
Year
Acquired/
Purchased
4th Character
(alpha)
5th Character
(alpha)
Features
Other
Options
Character
0
1
2
3
4
5
6
7
712
Next 2
Digits*
A
B
C
D
F
G
H
I
J
K
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
Prepared by:
MSAM Standards
Definition
Converted 1 or 2 to line-to-ground application
(with x2 multiplier)
1-stator, single-phase self-contained (3W)
1-stator, single-phase transformer-rated (3W)
3-stator, polyphase, self-contained
3-stator, polyphase, transformer-rated
2-stator, polyphase, self-contained
2-stator, polyphase, transformer-rated
1-stator, single-phase self-contained (2W)
2-stator, polyphase, transformer-rated
Ex. 00 Acquired in Year 2000
03 Acquired in Year 2003
07 Acquired in Year 2007 (etc.)
KWh (plain electro-mechanical meter)
KWh (plain electronic meter)
KWh, TOU Ready
KWh, TOU Ready, LP
KWh, kW, TOU Ready
KWh, kW, TOU Ready, LP
KWh, kW, kVarh
KWh, kW, kVarh, TOU Ready
KWh, kW, kVarh, TOU Ready, LP
KWh, kW, kVarh, TOU Ready, LP,
+ Transformer Loss Compensation
None
With internal telephone modem
With PLC module
With radio modem
With RS-232 universal communication port
Activated TOU rates with no other option
Activated TOU rates & with internal telephone modem
Activated TOU rates & with PLC module
Activated TOU rates & with radio modem
Activated TOU rates & with RS-232 universal
communication port
With RS-485 universal communication port
Activated TOU rates with RS-485 universal
communication port
With internal GSM/GPRS modem
With remote service disconnect
With RS-232 universal communication port plus
external GPRS/GSM modem
Reviewed by:
Approved by:
Team Leaders, Metering Services Asset
Head, Metering Services
Management
Asset Management
The document is considered uncontrolled if printed
PROCEDURES MANUAL
METERING STANDARDS
Section: Technical Guidelines
PM-DME-900.01
Page 2 of 5
Rev. Code: 5
Effectivity Date: September 1, 2012
Location
6th to 11th
Character
(numeric)
Designation
Sequential
Numbering
Prepared by:
MSAM Standards
Character
6-digit
Definition
Successive numbers from 000001 up to a certain
value. The last value is also known as the total range
which represents the volume of meters awarded to a
particular meter vendor.
Reviewed by:
Approved by:
Team Leaders, Metering Services Asset
Head, Metering Services
Management
Asset Management
The document is considered uncontrolled if printed
PROCEDURES MANUAL
METERING STANDARDS
Section: Technical Guidelines
PM-DME-900.01
Page 3 of 5
Rev. Code: 5
Effectivity Date: September 1, 2012
1.2
Location
Designation
st
1
Character
(alpha
Application
Type
Year
Acquired/
Purchased
4th Character
(alpha)
5th Character
(alpha)
Features
Other
Options
Character
0
1
2
3
4
5
6
7
712
Next 2
Digits*
A
B
C
D
E
F
G
H
I
J
K
L
P
A
B
C
D
E
F
G
H
I
J
K
L
M
N
Prepared by:
MSAM Standards
Definition
Converted 1 or 2 to line-to-ground application (with
x2 multiplier)
1-stator, single-phase self-contained (3W)
1-stator, single-phase transformer-rated (3W)
3-stator, polyphase, self-contained
3-stator, polyphase, transformer-rated
2-stator, polyphase, self-contained
2-stator, polyphase, transformer-rated
1-stator, single-phase self-contained (2W)
2-stator, polyphase, transformer-rated
Ex. 00 Acquired in Year 2000
03 Acquired in Year 2003
07 Acquired in Year 2007 (etc.)
KWh (plain electro-mechanical meter)
KWh (plain electronic meter)
KWh, TOU Ready
KWh, TOU Ready, LP
KWh (plain electronic), EMC meter
KWh, kW, TOU Ready
KWh, kW, TOU Ready, LP
KWh, kW, kVarh
KWh, kW, kVarh, TOU Ready
KWh, kW, kVarh, TOU Ready, LP
KWh, kW, kVarh, TOU Ready, LP,
+ Transformer Loss Compensation
KWh Delivered , kW Delivered , kWh Received , kW Received
Proof-of-Concept Meters (interim)
None
With internal telephone modem
With PLC module
With radio modem
With RS-232 universal communication port
Activated TOU rates with no other option
Activated TOU rates & with internal telephone modem
Activated TOU rates & with PLC module
Activated TOU rates & with radio modem
Activated TOU rates & with RS-232 universal
communication port
With RS-485 universal communication port
Activated TOU rates with RS-485 universal
communication port
With internal GSM/GPRS modem
With internal RF modem plus remote service disconnect
Reviewed by:
Approved by:
Team Leaders, Metering Services Asset
Head, Metering Services
Management
Asset Management
The document is considered uncontrolled if printed
PROCEDURES MANUAL
METERING STANDARDS
Section: Technical Guidelines
PM-DME-900.01
Page 4 of 5
Rev. Code: 5
Effectivity Date: September 1, 2012
6th Character
(alpha)
Brand
7th to 11th
Character
(numeric)
Sequential
Numbering
E
G
L
R
C
H
N
5-digit
Note: * Except for 712 series. For example, 712JE061234, the 06 next to 712JE is the acquired
year, 2006, and the 1234 is the series range.
Revision History
03.17.2010
01.31.2011
02.09.2011
Prepared by:
MSAM Standards
Reviewed by:
Approved by:
Team Leaders, Metering Services Asset
Head, Metering Services
Management
Asset Management
The document is considered uncontrolled if printed
PROCEDURES MANUAL
METERING STANDARDS
Section: Technical Guidelines
PM-DME-900.01
Page 5 of 5
Rev. Code: 5
Effectivity Date: September 1, 2012
08.16.2012
Prepared by:
MSAM Standards
Reviewed by:
Approved by:
Team Leaders, Metering Services Asset
Head, Metering Services
Management
Asset Management
The document is considered uncontrolled if printed